10.07.2015 Views

Sensys Evo TG-DSC - EXPERTA

Sensys Evo TG-DSC - EXPERTA

Sensys Evo TG-DSC - EXPERTA

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The SENSYS evo <strong>TG</strong>-<strong>DSC</strong> offers the most precise <strong>DSC</strong> sensor togetherwith a truly symmetrical microbalance to give YOU a combined <strong>TG</strong>-<strong>DSC</strong> system with totally unmatched performance. Additionally bothmeasurement sensors are totally independent, so can be operatedindependently or simultaneously without compromising performance.HIGHLIGHTS include:Differential Scanning Calorimeter• Incomparable precision: the unique 3D <strong>DSC</strong> sensor totally surrounds your sample and referencecrucibles so that the entire energy of any transformation is monitored thereby giving you an unequalledaccuracy of measurement.• Parameter Independent Calibration: because of the 3D transducer the calibration of SENSYS evo isindependent of:• mass and form (powder, fibre, liquid, etc.) of the sample,• contact between the sample and the transducer,• crucible type,• sweeping gas (inert, oxidizing, reducing, wet, pressure) and flow rate.Thermogravimetry• Excellent <strong>TG</strong> signal baseline: the symmetry of the microbalance, with its sample and referencesuspended vertically from the beam guarantee reproducible positioning of the sample over time andexcellent stability of the <strong>TG</strong> signal baseline.• Automatic compensation of Buoyancy: the sample and the reference are heated inside the same calorimetricblock (symmetrical furnace), which means that the buoyancy effect is automatically compensated.Ease of operation: dedicated market leading CALISTO software that is not only intuitive but powerful enough toperform every typical experiments and data treatment.3D <strong>DSC</strong> SENSOR3D SensorThe sample and reference sensorsare composed of 120 thermocouplesmounted in a cylinder that totallysurrounds the measurement zone. Thesetwo cylinders can measure up to 94 %of all heat exchanged with the sample/reference, as compared to 20 % typically(50 % absolute maximum) with 2D placesensors.The sensors are mounted in a calorimetricblock that is further water cooled toeliminate any environmental variationsand therefore giving you a highly preciseand robust sensor with a unique level ofspecific sensitivity. For studies at subambienttemperature, an automatedcooling device utilizing evaporation ofliquid nitrogen can be fitted onto thecalorimetric unit.See SENSYS <strong>TG</strong>-<strong>DSC</strong> evo application notesI N S P I R I N G I M A G I N A T I O N

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!