10.07.2015 Views

Sensys Evo TG-DSC - EXPERTA

Sensys Evo TG-DSC - EXPERTA

Sensys Evo TG-DSC - EXPERTA

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

APPLICATIONSWith its high precision and wide temperature range (-120 to 830 °C) the SENSYS evo <strong>TG</strong>-<strong>DSC</strong> has a wide range of applications, especiallyin the fields of thermodynamics (Specific Heat Capacity Cp accuracy within +/-1 %), pharmaceuticals (phase diagram, polymorphism,purity, thermal stability), safety of chemical process (transition, decomposition under high pressure), energy (catalysis, hydrogen storage,hydrogen adsorption), polymers (glass transition, measurement under pressure), etc.View the application notes in your field, available for download, by visiting www.setaram.com!A huge database is in the application library area of our website. We have also included a powerful search engine that will enable youto find the most applicable data.SPECIFICATIONSTemperature range Ambient to 830 °CWith cooling accessories-120 °C to 200 °C (Liquid Nitrogen Accessory)Temperature accuracy +/-0.1 °CProgrammable temperature scanning rate 0.01 to 30 °C min -1<strong>DSC</strong>Calorimetric Precision +/-0.1 %RMS Noise0.2 μWResolution0.35 μW / 0.035 μWGases3 carrier gases (MFC from 4 to 200 ml/min) + 1 auxiliary or reactivegas (MFC from 0.3 to 16 ml/min)*Pressure option (non controlled)High Pressure Crucible (up to 500 bars / 7250 psi at 600 °C)Pressure option (measured & controlled)High Pressure Crucible (up to 350 bars / 5800 psi at 800 °C)<strong>TG</strong>Maximum balance capacity3 gWeight range+/-200 mgWeighing precision +/-0.01 %<strong>TG</strong> Resolution0.02 μg, 0.002 μgBaseline dynamic drift< 10 μgIsothermal temperature accuracy +/-0.1 °CVacuum< 10-1 mbar<strong>Evo</strong>lved gasMS, FTIR, GC couplingsWeight55 kg (121 lbs)Dimensions (Height / Width / Depth)60 closed, 80 opened / 53 / 58 cm(23,6 closed, 31.4 opened / 20.9 / 22.8 in)Power requirements230 V - 50/60 HzOption : AKTS Thermokinetics software for comprehensive investigation of reaction or decomposition*MFC = Mass Flow Controllerpirana.net • Specifications are given as indications only and are not contractual • 10/14CONTACTSSETARAM Instrumentation7 rue de l’Oratoire69300 Caluire - FrancePhone +33 (0)4 72 10 25 25Fax +33 (0)4 78 28 63 55www.setaram.comsales@setaram.comOffices in United States, China, Germany, RussiaA trademark of KEP Technologies groupwww.kep-technologies.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!