P ro d u c t C ata l o g u e • J a n ua ry 2 0 1 2Energy Saving • Security • Convenience


IntroductionElectronic controlsDANLERS Limited design and manufacture a range of high quality electronicswitches for the control of lighting, heating, ventilation and air conditioning.Energy saving, security and convenience are among the many benefits offered byDANLERS controls.The products are straightforward to install and generally use the existing wiring,making them suitable for retrofitting or new installations. The energy saving productsinclude relays with special high surge contact material. These products are designedto switch up to 6 amps (1500W at 230VAC) of resistive, transformer or fluorescentlighting loads, or up to 1amp (250W) of fans.Bespoke and O.E.M products and servicesSpecial versions of our products can be made to suit customers’ needs.DANLERS also design and manufacture bespoke versions for Original EquipmentManufacturers.DANLERS also offer manufacturing services, including surface mount andthrough hole electronic assembly. Please enquire for further details or visitwww.danlerscem.co.ukCustomer serviceWe pride ourselves on giving personal service and prompt response to customers’needs. Please call us if you require further catalogues in this A4 format or in asmaller DL (1/3 A4) format.Display boards for trade counters or show rooms are also available on requestand free of charge in 3 sizes (500 x 575mm wall mounted, A3 - 420 x 297mm wallmounted, Counter top dispenser). Each has a DL (1/3 A4) catalogue dispenser.Quality Assurance• DANLERS Limited is an ISO9001 and ISO14001 accredited company.• Every product is tested after manufacture as standard.• All relevant DANLERS products carry the CE mark.• All DANLERS electronic switches comply with Directive 93/68/EEC (ElectricalEquipment Safety Regulations 1994) and with Standard EN 60669-2-1(Electronic Switches).• DANLERS dimmer switches also meet Standard BS EN 55015: 1993.• DANLERS products enable compliance with the requirements of the BuildingRegulations Approved Documents L2A and L2B for the Conservation of Fueland Power and with the recommendations of the 2nd tier document:- BREDigest 498 - “Selecting Lighting Controls”.• Many of DANLERS’ energy saving products qualify for the Enhanced CapitalAllowance Scheme run by the Carbon Trust.• All products are manufactured by DANLERS in the U.K. except for the radioremote controls which are manufactured in Austria and the U.K.• Our warranty extends to five years from the date of manufacture.ISO 9001: 2008Registration No. 879When installing any DANLERS products, please ensure that the most recent editionof the appropriate local wiring regulations has been observed and that appropriateprotective measures have been applied.DANLERS Limited has a policy of continuous development. The right is reserved tochange specifications without prior notification or public announcement.ISO 14001: 2004Registration No. 879DANLERS Limited, DANLERS Business Centre, Vincients Road, CHIPPENHAM,Wiltshire, SN14 6NQ United Kingdom.Tel:+44 (0)1249 443377. Fax:+44 (0)1249 443388. E-mail: sales@danlers.co.ukwww.danlers.co.uk3


CONTENTS44-45 Quiet dimmers (trailing edge)Push button action in grid versions.Suitable for dimming: Incandescent lamps, mains halogen lamps(must include integral safety fuse), most directly dimmable LED lamps,dimmable electronic transformers.Multi-way switching AND dimming using matching slaves.46-47 Soft start dimmers (leading edge)Push button action in high quality plates or grid versions. Soft startdimming for tungsten, mains halogen and dimmable transformer loads.Multi-way switching AND dimming using matching slaves.Versions up to 630W.48-49 Push and rotary dimmers (leading edge)Versions for tungsten, mains halogen and dimmable transformer loads.Versions up to 1000W. 1, 2, 3 and 4 gang plates.1-way and 2-way switching.50-51 Manual high frequency dimmersManual push dimmers for fluorescent loads with dimmable highfrequency ballasts. Plated versions and Grid module versions.Versions suitable for dimmable ballasts with 1-10VDC input.Version suitable for DSI dimmable ballasts.52-53 HVAC controlsFor Heating, Ventilation and Air Conditioning.PIR thermostat controls which combine PIR person detector with roomthermostat. Versions for heating and cooling loads.Heater boost switch with selectable time lag.Fan speed control.54-64 Radio remote and Active infra-red controlsRemote control switching and dimming. Hand held or wire-free wallmounted senders. Receiver switches and dimmers for indoor or outdoormounting.Active infra-red remote control switching and dimming for shorter range"line of sight" applications.65 Additional productsPattress box for surface-mounted ceiling products.Ceiling box for ceiling socket.Test plug for ceiling socket or slave relays.Load resistor to augment small loads.66-71 Bespoke / O.E.M. products, manufacturing servicesand relay optionsProducts for Original Equipment Manufacturers including PIR occupancyswitches, Time lag switches, Controls with low voltage inputs and withlow voltage, volt-free outputs.Dimmer modules and Time lag modules for O.E.M’s. to assemble ontotheir own plates.Manufacturing services, including surface mount and through holeelectronic assembly.5


PIR OCCUPANCY SWITCHESPIR occupancy switchesThe DANLERS range of passive infra-red occupancy switches is designed for theautomatic control of lighting, heating, ventilation or air conditioning loads.The PIR switch will switch on the connected load automatically when an area is occupied,and then switch it off automatically when the area has been vacant for a chosen duration.This has the benefits of reduced energy bills and automatic control. When being used tocontrol lighting, the built-in photocell can be used to keep the lights off on bright days.PIR occupancy switches are ideal for:• Offices• Factories• Warehouses• Schools• Leisure centres• Hospitals• Canteens• Staff rooms• Corridors and stairwells• Residential homes• Military accommodation• Student accommodation• Toilet blocks• Changing rooms• Plus many other usesPIR occupancy switch variantsSpecial variants of products are available on request such as 24V (a.c. or d.c.) versionsof our PIR occupancy switches and photocell switches, ideal for low voltage controlsystems. 12V variants can also be supplied. Some variants are available from stock fornext day delivery. To special order we can also supply volt free outputs for mains, 24V or12V supplies (including versions with gold relays).6


PIR OCCUPANCY SWITCHESPIR occupancy switch functionsEach PIR occupancy switch in the DANLERS range has a passive infra-red quad persondetector (except COPD and BMPIR which have a passive infra-red dual person detector).This detects the movement of a warm body moving within its detection zone. When sucha movement is detected the load is switched on. There is a time lag function which isadjusted using a spindle on the side of the product. The time lag is the time that mustelapse with no movement detected before the PIR occupancy switch will switch off.Simple adjustment spindlesThere is a built-in, adjustable, photocell override which can be used to keep lights offwhen there is sufficient daylight available. The photocell can only be used in this way ifthe amount of natural daylight exceeds the level of the artificial lights. The photocell canbe set to inactive when controlling heating, ventilation or air conditioning. The photocell isalso adjusted by a spindle on the side of the product.Each PIR occupancy switch contains a relay suitable for switching any type of load,including fluorescent lights and fans.A few PIR occupancy switches may be wired in parallel to control the same load.However, there are minimum load restrictions with the WAPIR model only (see page 21).The PIR occupancy switches require a mains supply.Function demonstrated with the lighting in an officePIR occupancy switch brings lights on – only when neededEnough daylight, Occupied –Lighting OFFEnough daylight, Unoccupied –Lighting OFFNight, Occupied –Lighting ONNight, Unoccupied –Lighting OFF7


PIR OCCUPANCY SWITCHESPIR occupancy switch specificationsPIR detectorPassive infra-red quad person detector.Adjustable time lagTime lag adjustable in 9 steps (approximate values):10 seconds 20 seconds 40 seconds1.25 minutes 2.5 minutes 5 minutes10 minutes 20 minutes 40 minutesAdjustable photocell"Inhibit on" photocell. The photocell will inhibit the lights from switching on whensomebody enters an area with plenty of ambient light. However, if somebody is alreadyoccupying an area with the lights switched on, the lights will remain on while the areais occupied, regardless of any increase in the ambient light level. This is to avoid anynuisance switching off when somebody is in the middle of a task or meeting.Range 100-1000 lux (and photocell inactive), falling on the working plane.LoadingAll models can switch up to 6 amps (1500W at 230VAC) of resistive, transformer orfluorescent lighting loads, 2 amps (500W) of low energy lighting loads (LED lamps andcompact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps. For theWAPIR model there are some minimum load requirements (details on page 21).Wiring in parallelA few PIR switches can be wired in parallel to control the same load.Start-up ModeWhen the mains supply is initially connected to the PIR occupancy switch it goes throughits Start-up Mode. This means it switches on for about 1 minute, then switches off andenters its Operating Mode. If a manual wall switch is feeding the PIR occupancy switch(see wiring diagrams on appropriate product pages) then it will go through the Start-upMode each time the wall switch is switched on (not applicable to WAPIR, see page 21).By wiring the manual wall switch in the alternative position, the supply to the PIRoccupancy switch is uninterrupted and it remains in Operating Mode. It does not gothrough its Start-up Mode each time the wall switch is switched on.8


PIR OCCUPANCY SWITCHESSelecting the appropriate PIR occupancy switchCEILING MOUNTEDWALLMOUNTED360˚detection zone120˚directionaldetectionangleLong rangedirectionalnarrowbeam120˚detectionangleFlush-mounted(false or plasterboard ceilings)SurfacemountedSurfacemountedSurfacemountedPlaster depth(16mm) wall boxHardwiredHardwiredHardwiredPlug andsocketHardwiredPlug andsocketPlug andsocketPlug andsocketNeedsneutralwireNo neutralwireneededCEFL PIRCEFL PIRSEALEDCEFL PIR10ACEFLP PIR+ CESOCESF PIRCELO +CESO SQCEDR 6P+ CESOCEDR 6PLR+ CESOWACE PIRWAPIRPage 12Page 13Page 13Page 12Page 15Page 16Page 18Page 19Page 20Page 219


PIR OCCUPANCY SWITCHESTwo ceiling flushmountedCEFL PIRcontrolling thelights in a meetingroom. In this, andother offices, amanual wall switchis retained tooverride the lightsto off,e.g. for a videopresentation.Small officesare covered bya single ceilingflush-mountedCEFL PIR.The wall switchhas beenreplaced by awall mountedWAPIR.MEETING ROOMOFFICEOFFICEOFFICECORRIDORLong rangedirectionalCEDR 6PLR todetect peoplein the 25 metrecorridor.OPEN PLAN OFFICESScale05m10mApplication diagramThe diagram illustrates PIR occupancy switch siting within a typical office/factory facility. The coloured zones emanating from the controls show strongdetection zones (darker tints with solid coloured line) and secondary detectionzones (lighter tint with broken coloured line).Ceiling flush-mountedCEFL PIR spaced every5 metres to cover theopen plan office andcontrol the lights. TheCEFL PIR can be wiredin groups in parallel, tocontrol the lighting inzones.10


Two ceilingsurfacemountedCESF PIR(one on eachlanding) wiredin parallel tocontrol thelighting in thestairwell.In the toilets aceiling flushmountedCEFL PIR hasbeen wired inparallel with a wallmountedWACE PIR in thelobby, to controlthe lighting in bothrooms together.In the shower room aCEFL PIR SEALEDis used, as it hasprotection againstlight splashes andcondensation.CeilingdirectionalCEDR 6Pcovers the openstaircase.TOILETSTOILETLOBBYSHOWERROOMOPENSTAIRCASESTAIRWELLFACTORY AREARESTROOMHIGH BAYRACKINGHIGH BAYRACKINGLong rangedirectionalCEDR 6PLRdetects people ina racking storageaisle.RECEPTIONCeiling flushmountedCEFL PIR spacedevery 5 metres tocover the open planreception area andcontrol the lights.Ceiling plug-inCELO mountedon BESA box onceiling conduit.Spaced at 5 metreintervals to controlthe lights in therestroom.Ceiling surfacemountedCESF PIRspaced every 5metres to givetotal coverageof the open planfactory area.11


PIR OCCUPANCY SWITCHESThese neat and unobtrusive models are ideal for flush mounting through suspended orplasterboard ceilings. They have a 2m cable, for quick and easy installation.Ceiling flush-mounted PIR occupancy switchOrder code:CEFL PIRSpecificationDetection zone: 360°Time lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 6 amps (1500W) of resistive, transformer orfluorescent lighting loads, 2 amps (500W) of lowenergy lighting loads (LED lamps and compactfluorescent) or up to 1 amp (250W) of fans or mostmetal halide lampsSee diagrams 12a and 12b below72mm diameter x 68mmIdeal for false orplasterboardceilingsOrder code:CEFLP PIRSpecial versionsPlug and socket version: CEFLP PIRModel CEFLP PIR is provided with a plug suitable for theCESO Ceiling socket shown on page 17.Loading:Up to 6 amps (1500W) of resistive, transformer orfluorescent lighting loads, 2 amps (500W) of lowenergy lighting loads (LED lamps and compactfluorescent) or up to 1 amp (250W) of fans or mostmetal halide lampsControl pluggedinto a CESO ona BESA boxPIR occupancy switch variantsVariants are available on request such as 24V or 12V (a.c. or d.c.), ideal for low voltagecontrol systems. To special order we can also supply volt free outputs for mains, 24V or12V supplies (including versions with gold contact relays).Detection diagramsPlan view of detection zoneFig. 201 Ceiling mounted PIR occupancy switchPerspective view of detection zoneSeveral PIR occupancy switchesUp to 5mUp to 7mStrong detection zone i.e. personmoving armSecondary detection zone i.e. personwalking (less sensitive when walkingstraight towards PIR switch)For optimum coveragerecommended mountingheight between 2.4 and 5m.PIR Quad detectorgives 124 detectionareas within the zone.CEFL PIRUp to 5mUp to 7mStrongdetectionzoneSecondarydetectionzoneIn open plan areasFor best coverage the CEFL PIR should be spaced every5m in either directionUp to 5mUp to5mDimensions in mmWiring diagrams66side2m cable6072553plan3872Requires 63 or 64mm (2.5")diameter hole in a falseor plasterboard ceiling12a. Single CEFL PIR 12b. A few CEFL PIR wired in parallelLNoptional manualwall switch foroverriding off230 VACCEFL PIRSLalternative positionfor optional wallswitch (see p.8“Start-up Mode”)loadLN230 VACoptional manual wall switchfor overriding offSL SL SLA few CEFL PIRalternativeposition foroptionalwall switch(see p.8“Start-upMode”)load12


PIR OCCUPANCY SWITCHESThese neat and unobtrusive models are ideal for flush mounting through suspended orplasterboard ceilings. They have a 2m cable, for quick and easy installation.Splashproof ceiling flush-mounted PIR occupancy switchOrder code:CEFL PIR SEALEDModel CEFL PIR SEALED is protected against light splashes and condensation wheninstalled in the ceiling. Ideal for bathrooms, shower rooms, etc.SpecificationDetection zone: 360°Time lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 6 amps (1500W) of resistive, transformer or fluorescent lightingloads, 2 amps (500W) of low energy lighting loads (LED lamps andcompact fluorescent) or up to 1 amp (250W) of fans or most metalhalide lampsSee diagrams 13a and 13b below72mm diameter x 68mmAn extra sealed version is also available on request (order code: CEFL PIR SEALED XS).10 amp rated ceiling flush-mounted PIR occupancy switchOrder code:CEFL PIR 10ASpecificationDetection zone: 360°Time lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 10 amps (2500W) of resistive, transformer or fluorescent lightingloads, 2 amps (500W) of low energy lighting loads (LED lamps andcompact fluorescent) or up to 1 amp (250W) of fans or most metalhalide lampsSee diagrams 13a and 13b below72mm diameter x 68mmDetection diagramsPlan view of detection zoneFig. 201 Ceiling mounted PIR occupancy switchPerspective view of detection zoneSeveral PIR occupancy switchesUp to 5mUp to 7mStrong detection zone i.e. personmoving armSecondary detection zone i.e. personwalking (less sensitive when walkingstraight towards PIR switch)For optimum coveragerecommended mountingheight between 2.4 and 5m.PIR Quad detectorgives 124 detectionareas within the zone.CEFL PIRUp to 5mUp to 7mStrongdetectionzoneSecondarydetectionzoneIn open plan areasFor best coverage the CEFL PIR should be spaced every5m in either directionUp to 5mUp to5mDimensions in mmWiring diagrams66side2m cable6072553plan3872Requires 63 or 64mm (2.5")diameter hole in a falseor plasterboard ceiling13a. Single PIR occupancy switch 13b. A few PIR occupancy switches wiredin parallelPIR alternative positionoccupancy for optional walloptional manual wall switchswitchswitch (see p.8for overriding offSL “Start-up Mode”)LNoptional manualwall switch foroverriding off230 VACloadLN230 VACSL SL SLA few PIR occupancyswitchesalternativeposition foroptionalwall switch(see p.8“Start-upMode”)13


PIR OCCUPANCY SWITCHESDANLERS manufacture a range of variants of the Ceiling flush-mounted PIR for integratinginto building management systems, low voltage applications etc.Ceiling flush-mounted PIR occupancy switch variants12 volt version: CEFL PIR 12VOperating voltage of the switch is 12 volt a.c. or d.c.12 volt version with volt free contacts: CEFL PIR 12VVFOperating voltage of the switch is 12 volt a.c. or d.c. Comes with 4-core flex.24 volt version: CEFL PIR 24VOperating voltage of the switch is 24 volt a.c. or d.c.Order code:CEFL PIR 12VCEFL PIR 12VVFCEFL PIR 24VCEFL PIR 24VVF24 volt version with volt free contacts: CEFL PIR 24VVFOperating voltage of the switch is 24 volt a.c. or d.c. Comes with 4-core flex.SpecificationDetection zone: 360°Time lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactive12V to 240V: 10mA to 6 amps of resistive, transformer orfluorescent lighting loads, 2 amps of low energy lighting loads (LEDlamps and compact fluorescent) or up to 1 amp of fans or most metalhalide lampsSee diagrams 14a and 14b below72mm diameter x 68mmOther PIR occupancy switch variantsDANLERS also manufacture many other variants of their PIR occupancy switchesincluding the following variants:• Normally closed contacts• Gold contacts• Double detection to reduce false triggering• Reduced sensitivity to reduce false triggering• Extra sealed for draughty environmentsDetection diagramsPlan view of detection zoneFig. 201 Ceiling mounted PIR occupancy switchPerspective view of detection zoneSeveral PIR occupancy switchesUp to 5mUp to 7mStrong detection zone i.e. personmoving armSecondary detection zone i.e. personwalking (less sensitive when walkingstraight towards PIR switch)For optimum coveragerecommended mountingheight between 2.4 and 5m.PIR Quad detectorgives 124 detectionareas within the zone.CEFL PIRUp to 5mUp to 7mStrongdetectionzoneSecondarydetectionzoneIn open plan areasFor best coverage the CEFL PIR should be spaced every5m in either directionUp to 5mUp to5mDimensions in mmWiring diagramsside2m cableplan3814a. Volt free,normally openVolt Free, Normally Open14b. Volt free,normally closedVolt Free, Normally Closed6655SupplyVoltageNOSupplyVoltageNC3607272Requires 63 or 64mm (2.5")diameter hole in a falseor plasterboard ceilingNeutralor 0VLoadNeutralor 0VLoad14


PIR OCCUPANCY SWITCHESThese surface-mounted models are ideal for solid ceilings.Ceiling surface-mounted PIR occupancy switchThe CESF PIR is a hard wired version and can be mounted on a square pattress box.Order code:CESF PIRSpecificationDetection zone: 360°Time lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 6 amps (1500W) of resistive, transformer or fluorescent lightingloads, 2 amps (500W) of low energy lighting loads (LED lamps andcompact fluorescent) or up to 1 amp (250W) of fans or most metalhalide lampsSee diagrams 15a and 15b below86 x 86 x 22mm. Requires back box depth 16mmCan be mounted on a square pattress box, order code: PABO.Ceiling surface-mounted PIR occupancy switch variantsVariants are available on request such as 24V or 12V (a.c. or d.c.), ideal for low voltagecontrol systems. To special order we can also supply volt free outputs for mains, 24V or12V supplies (including versions with gold contact relays).Detection diagramsPlan view of detection zoneFig. 201 Ceiling mounted PIR occupancy switchPerspective view of detection zoneSeveral PIR occupancy switchesUp to 5mUp to 7mStrong detection zone i.e. personmoving armSecondary detection zone i.e. personwalking (less sensitive when walkingstraight towards PIR switch)For optimum coveragerecommended mountingheight between 2.4 and 5m.PIR Quad detectorgives 124 detectionareas within the zone.CESF PIRUp to 5mUp to 7mStrongdetectionzoneSecondarydetectionzoneIn open plan areasFor best coverage the CESF PIR should be spaced every5m in either directionUp to 5mUp to5mDimensions in mmWiring diagramsRequires 16mm deep box15a. Single CESF PIR15b. A few CESF PIR wired in parallelplan8686side22Loptional manualwall switch foroverriding off230 VACCESF PIRSLalternative positionfor optional wallswitch (see p.8“Start-up Mode”)loadL230 VACoptional manual wall switchfor overriding offSL SL SLA few CESF PIRalternativeposition foroptionalwall switch(see p.8“Start-upMode”)NNload15


PIR OCCUPANCY SWITCHESThese surface-mounted models are ideal for solid ceilings.Ceiling surface-mounted plug-in PIR occupancy switchOrder code:CELORequires socket, order code:CESO SQ or CESO(see page 17)The CELO has a built-in plug suitable for the CESO SQ Ceiling socket (or CESO Ceilingsocket). CESO SQ can be mounted on a square pattress box (the CESO can be mountedon a BESA box).SpecificationDetection zone: 360°Time lag range:10 seconds to 40 minutes in 9 stepsPhotocell range: 100 to 1000 lux, and inactiveLoading:Wiring diagram:Dimensions:(Each circuit) up to 6 amps (1500W) of resistive,transformer or fluorescent lighting loads,2 amps (500W) of low energy lighting loads (LEDlamps and compact fluorescent) or up to 1 amp(250W) of fans or most metal halide lamps.See diagrams 16a, 16b, 16c below88 x 88 x 47mmDetection diagramsPlan view of detection zonePerspective view of detection zoneSeveral PIR occupancy switchesUp to 5mUp to 7mStrong detection zone i.e. personmoving armSecondary detection zone i.e. personwalking (less sensitive when walkingstraight towards PIR switch)For optimum coveragerecommended mountingheight between 2.4 and 5m.PIR Quad detectorgives 124 detectionareas within the zone.CELOUp to 5mUp to 7mStrongdetectionzoneSecondarydetectionzoneIn open plan areasFor best coverage the CELO should be spaced every5m in either directionUp to 5mUp to5mDimensions in mmplanside88(CESO SQ)8847Wiring diagrams16a. Single CELO 16b. A few CELO wired in parallelLoptional manualwall switch foroverriding off230 VACCELOSLalternative positionfor optional wallswitch (see p.8“Start-up Mode”)loadL230 VACoptional manual wall switchfor overriding offCELOCELOCELOSL SL SLalternativeposition foroptionalwall switch(see p.8“Start-upMode”)16c. Ceiling mounted socket (CESO SQor CESO)L NPattressbox orBESAboxL N ACESO SQor CESOluminaireSLNNloadL N SL CELO Not to scale16


ANCILLARY PRODUCTSSockets for plug-in ceiling controlsCeiling socket: CESOFor use with DANLERS plug-in ceiling controls. Can be mounted on a BESA box.Wiring diagram: See diagram 17a belowDimensions: 74mm diameter x 13mmAlso available as a square socket.Order code: CESOCeiling socket: CESO SQCan be mounted on a square pattress box.Wiring diagram: See diagram 17a belowDimensions: 87 x 87 x 13mmSlave relays for plug-in ceiling controlsOrder code:CESO SQOrder code:CESL or CE2SLCeiling socket with slave relay: CESLCeiling socket with slave relay with isolated changeover contacts. Enables the switchingof an additional circuit with its own supply, e.g. the corridor lights outside an office or aseparate low voltage control circuit. A no socket version is available on request.Loading:Wiring diagram:Dimensions:(Each circuit) up to 6 amps (1500W) incandescent or mains halogen lamps.Up to 4 amps (1000W) electronic or wire wound transformers, fluorescentlamps (high frequency or soft start).Up to 2 amps (500W) compact fluorescent or LED lamps.Up to 1 amp (250W) most fans and metal halide discharge lamps.See diagram 17b below87 x 87 x 41mmCeiling socket with double slave relay: CE2SLCeiling socket with a double slave relay with isolated changeover contacts. Enables theswitching of two additional circuits, each with its own supply, e.g. the corridor lightsoutside an office, plus the extractor fans inside the office. Also ideal for controlling twoseparate low voltage control circuits. A no socket version is available on request.Loading:Wiring diagram:Dimensions:As CESL aboveSee diagram 17c below87 x 87 x 41mmDimensions in mmCeiling socket (CESO)Ceiling socket (CESO SQ)Ceiling slave relays (CESL / CE2SL)side13plansideplanside7487878787plan87138741Wiring diagrams17a. Ceiling mounted socket (CESO orCESO SQ) for plug-in ceiling controlsL NBESAbox orpattressboxL N AL N SLCESO orCESO SQplug-in ceilingcontrolluminaireSLNot to scale17b. Plug-in control plus slave relay with voltfree changeover contacts (CESL)controlling one extra circuitN1SL2N/Oseparate circuitC2SL2N/CL1optional manual CESL SL1wall switch for plusoverriding off plug-inswitch230 VAC load17c. Plug-in control plus double slave relaywith volt free changeover contacts(CE2SL) controlling two extra circuitsL1N1SL2N/O230 VACseparate circuitC2optional manualwall switch foroverriding offSL2N/CSL3N/Oseparate circuitCE2SLplusplug-inswitchC3SL1SL3N/Cload17


PIR OCCUPANCY SWITCHESThese directional PIR switches plug into a ceiling mounted socket. The socket can bemounted on a BESA box.Ceiling directional PIR occupancy switchStandard rangeOrder code:CEDR 6PRequires socket, order code:CESO(see page 17)Standard range versionDesigned to give a directional view of the activity to be monitored.Detection angle 120°.SpecificationTime lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 6 amps (1500W) of resistive,transformer or fluorescent lighting loads, 2amps (500W) of low energy lighting loads(LED lamps and compact fluorescent) or upto 1 amp (250W) of fans or most metal halidelampsSee diagrams 18a, 18b, 18c belowSee belowCEDR 6P can berotated and loweredto a 45º angleDetection diagramsPerspective viewPlan viewSide elevationCEDR 6P60°120°CEDR 6P60°120°StrongDetectionZoneSecondaryDetectionZoneStrongDetectionZoneSecondaryDetectionZoneCEDR 6PUp to 5mUp to 10mUp to 5mUp to 10mDimensions in mm(CESO)74side6460102Wiring diagrams18a. Single CEDR 6P 18b. A few CEDR 6P wired in parallel 18c. Ceiling mounted socket (CESO)Loptional manualwall switch foroverriding off230 VACCEDR 6PSLalternative positionfor optional wallswitch (see p.8“Start-up Mode”)loadL230 VACoptional manual wall switchfor overriding offSL SL SLA few CEDR 6Palternativeposition foroptionalwall switch(see p.8“Start-upMode”)BESAboxL N ACESOLNluminaireSLNNloadL N SLCEDR 6PNot to scale18


PIR OCCUPANCY SWITCHESThese directional PIR switches plug into a ceiling mounted socket. The socket can bemounted on a BESA box.Ceiling directional PIR occupancy switchLong rangeOrder code:CEDR 6PLRRequires socket, order code:CESO(see page 17)Long range versionWith a long range, narrow detection beam. Designed for corridors and storage aisles.SpecificationTime lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 6 amps (1500W) of resistive,transformer or fluorescent lighting loads, 2amps (500W) of low energy lighting loads(LED lamps and compact fluorescent) orup to 1 amp (250W) of fans or most metalhalide lampsSee diagrams 19a, 19b, 19c belowSee belowDANLERS also manufacture a Long range ceiling flushmounted PIR occupancy switch, order code CEFL PIR LRsee page 24 for details.CEDR 6PLR can berotated and loweredto a 45º angleDetection diagramsPerspective viewPlan viewCEDR 6PLR6°Up to 10mStrong Detection Zonei.e. person walking towards PIR15mUp to 25mSecondary Detection Zonei.e. person walking across the zoneSide elevationCEDR 6PLRCEDR 6PLRIdeal mounting height between 2.2 and 3mUp to 10m15mUp to 25mDimensions in mm(CESO)74side6460115Wiring diagrams19a. Single CEDR 6PLR 19b. A few CEDR 6PLR wired in parallel 19c. Ceiling mounted socket (CESO)Loptional manualwall switch foroverriding off230 VACCEDR 6PLRSLalternative positionfor optional wallswitch (see p.8“Start-up Mode”)loadL230 VACoptional manual wall switchfor overriding offSL SL SLA few CEDR 6PLRalternativeposition foroptionalwall switch(see p.8“Start-upMode”)BESAboxL N ACESOLNluminaireSLNNloadL N SL CEDR 6PLR Not to scale19


PIR OCCUPANCY SWITCHESThe WACE PIR is suitable for either wall or ceiling mounting. It fits either into a plasterdepth (16mm) wall box or onto a ceiling mounted square pattress box.It requires a neutral wire.Wall or ceiling mounted PIR occupancy switchApplicationsSuitable for stairwells, corridors, toilet lobbies, etc.Version incorporating override off button, enabling lights to be held off during videopresentations etc, available by request.Order code:WACE PIRSpecificationDetection angle: 120°Time lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 6 amps (1500W) of resistive, transformer or fluorescent lightingloads, 2 amps (500W) of low energy lighting loads (LED lamps andcompact fluorescent) or up to 1 amp (250W) of fans or most metalhalide lampsSee diagrams 20a and 20b below86 x 86 x 22mm. Wall box depth 16mmDetection diagramsPerspective viewPlan viewSide elevationWACE PIR120°60°StrongDetectionZoneSecondaryDetectionZoneWACE PIR45° 90°StrongDetectionZoneSecondaryDetectionZoneWall mounted PIR occupancy switchUp to 5mUp to 10mIdeal mounting height between 1 and 1.8mUp to 5mUp to 10mDimensions in mmWiring diagramsRequires 16mm deep box20a. Single WACE PIR 20b. A few WACE PIR wired in parallel,eg. in a stairwellplan86side22LWACE PIRSLLA few WACE PIR230 VAC86230 VACloadSL SL SLNNload20


PIR OCCUPANCY SWITCHESThe WAPIR model replaces an existing wall switch – no neutral wire is needed. It fits into aplaster depth (16mm) wall box. The WAPIR model also has a manual override off switch onthe front of the plate.Wall mounted PIR occupancy switchOrder code:WAPIRApplicationsThe WAPIR requires a permanent live supply and should only be used in applicationswhere the lights would not be on for more than 12 hours per day. This is to allow itsrechargeable battery enough time to recharge itself from the mains supply. The WAPIR issupplied with a load capacitor to augment small loads.The WAPIR is suitable for small offices, meeting rooms, tutoring rooms, etc.The override off button (out position) enables the lights to be held off during videopresentations, etc. A version without the manual override button is also available onrequest (order code WAPIRX).For wall mounting only.SpecificationDetection angle: 120°Time lag range:Photocell range:Maximum load:Minimum load:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 6 amps (1500W) of resistive, transformer or fluorescent lightingloads, 2 amps (500W) of low energy lighting loads (LED lamps andcompact fluorescent) or up to 1 amp (250W) of fans or most metalhalide lamps40W resistive or approximately 100W inductive per WAPIR in thecircuit.A load capacitor (CAPLOAD) is supplied to augment small loads.See diagram 21a and 21b below86 x 86 x 22mm. Wall box depth 16mmDetection diagramsPerspective viewPlan viewSide elevationWAPIR120°60°StrongDetectionZoneSecondaryDetectionZoneWAPIR45° 90°StrongDetectionZoneSecondaryDetectionZoneWall mounted PIR occupancy switchUp to 5mUp to 10mIdeal mounting height between 1 and 1.8mUp to 5mUp to 10mDimensions in mmWiring diagramsRequires 16mm deep wall box21a. Single WAPIR 21b. A few WAPIR wired in parallelplan86side22LWAPIRSLLWAPIR WAPIR WAPIR86230 VACload230 VACSLSLSLNNload21


PIR OCCUPANCY SWITCH MODULESThese modules are suitable for mounting onto Eurodata plates and fit into a 35mm deepwall box. They are also suitable for building into luminaires (see page 68 for fixing bezel).They require a neutral wire.5m detection - concealed adjustment spindlesOrder code:GREUW PIR5XAdjustment spindles hidden behind front surface lid for a neat finish (module must beremoved from wall plate or luminaire to adjust).Can be suited in with other Eurodata modules.SpecificationDetection zone: 360°Detection angle: 100°Time lag range:10 seconds to 40 minutes in 9 stepsPhotocell range: 15 to 1000 lux, and inactiveLoading:Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting loads,2 amps (500W) of low energy lighting loads (LED lamps and compactfluorescent) or up to 1 amp (250W) of fans or most metal halide lampsWiring diagram: See diagrams 22a and 22b belowDimensions:50 x 25 x 38mm, minimum wall box depth of 35mm5m detection - visible adjustment spindlesOrder code:GREUW PIR5EAdjustment spindles visible on front surface for quick and convenient adjustment.Can be suited in with other Eurodata modules.SpecificationDetection zone: 360°Detection angle: 100°Time lag range:10 seconds to 40 minutes in 9 stepsPhotocell range: 15 to 1000 lux, and inactiveLoading:Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting loads,2 amps (500W) of low energy lighting loads (LED lamps and compactfluorescent) or up to 1 amp (250W) of fans or most metal halide lampsWiring diagram: See diagrams 22a and 22b belowDimensions:50 x 25 x 38mm, minimum wall box depth of 35mmDetection diagramsPerspective view (ceiling mounted)Plan view (wall mounted)Side elevation (wall mounted)For optimumcoveragerecommendedmounting heightbetween 2.4and 5mGREUW PIR5X orGREUW PIR5EDetectionzoneGREUW PIR5X or GREUW PIR5E50° 100°DetectionZoneGREUW PIR5X or GREUW PIR5E40° 80°DetectionZoneUp to 7mUp to5mUp to 5mUp to 5mDimensions in mmDimensions in mmGREUW PIR5X, GREUW PIR5E.Requires wall box depth of 35mmfront2550side38Wiring diagrams22a. Single PIR occupancy switch module 22b. A few PIR occupancy switch moduleswired in parallel, eg. in a stairwellL230 VACPIR occupancyswitch moduleSLloadL230 VACSL SL SLA few PIR occupancyswitch modulesNNload22


PIR OCCUPANCY SWITCH MODULESThese modules are suitable for mounting onto Eurodata plates. They are also suitable forbuilding into luminaires (see page 68 for fixing bezel). They require a neutral wire.These versions are best suited for use in areas such as warehouses, sports halls andcirculation areas, where there is likely to be a significant level of movement.10m detection - concealed adjustment spindlesOrder code:GREUW PIR10XAdjustment spindles hidden behind front surface lid for a neat finish (module must beremoved from plate or luminaire to adjust). Can be suited in with other Eurodata modules.SpecificationDetection zone: 360°Time lag range:10 seconds to 40 minutes in 9 stepsPhotocell range: 15 to 1000 lux, and inactiveLoading:Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting loads,2 amps (500W) of low energy lighting loads (LED lamps and compactfluorescent) or up to 1 amp (250W) of fans or most metal halide lampsWiring diagram: See diagrams 23a and 23b belowDimensions:50 x 25 x 38mm, minimum back box depth of 35mmA photocell override version is available on request.10m detection - visible adjustment spindlesOrder code:GREUW PIR10EAdjustment spindles visible on front surface for quick and convenient adjustment. Suitablefor mounting onto a Eurodata plate. Can be suited in with other Eurodata modules.SpecificationDetection zone: 360°Time lag range:10 seconds to 40 minutes in 9 stepsPhotocell range: 15 to 1000 lux, and inactiveLoading:Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting loads,2 amps (500W) of low energy lighting loads (LED lamps and compactfluorescent) or up to 1 amp (250W) of fans or most metal halide lampsWiring diagram: See diagrams 23a and 23b belowDimensions:50 x 25 x 38mm, minimum back box depth of 35mmA photocell override version is available on request.Detection diagramsPerspective view (ceiling mounted)For optimumcoveragerecommendedmounting heightbetween 5and 10mGREUW PIR10X orGREUW PIR10EDetectionzoneUp to 15mUp to12mDimensions in mmDimensions in mmGREUW PIR10X, GREUW PIR10E.Requires back box depth of 35mmfront2550side38Wiring diagrams23a. Single PIR occupancy switch module 23b. A few PIR occupancy switch moduleswired in parallel, eg. in a stairwellLoptional manualwall switch foroverriding off230 VACPIR occupancyswitch moduleSLloadL230 VACSL SL SLA few PIR occupancyswitch modulesNNload23


PIR OCCUPANCY SWITCHESThis long range PIR occupancy switch is ideal for storage aisles and high bay applicationswhere a height of up to 20m is required.Ceiling mounted long range PIR occupancy switchWith a long range, narrow detection beam. Designed for warehouses and storage aisleswith a narrow point of access.CEFL PIR LR is also suitable for building into luminaires.Order code:CEFL PIR LRSpecificationTime lag range:Photocell range:Loading:Wiring diagram:Dimensions:10 seconds to 40 minutes in 9 steps100 to 1000 lux, and inactiveUp to 6 amps (1500W) of resistive, transformer or fluorescent lightingloads, 2 amps (500W) of low energy lighting loads (LED lamps andcompact fluorescent) or up to 1 amp (250W) of fans or most metalhalide lampsSee diagrams 24a and 24b belowSee belowA photocell override version of the above is available on request.DANLERS also manufacture a PIR occupancy switch module suitable for mounting ontoEurodata plates with a 12 metre range for storage aisles and warehouses (order codeGREUW PIR12E). Please call for further details.Detection diagramCEFL PIR LRStrongDetection Zonei.e. personmoving armUp to 10m15mUp to 20m6°SecondaryDetection Zonei.e. personwalking acrossthe zoneDimensions in mmWiring diagrams6617side2m cable6072553plan3872Requires 63 or 64mm (2.5")diameter hole in a falseor plasterboard ceiling24a. Single CEFL PIR LR 24b. A few CEFL PIR LR wired in parallelLNoptional manualwall switch foroverriding off230 VACCEFL PIR LRSLalternative positionfor optional wallswitch (see p.8“Start-up Mode”)loadL230 VACNoptional manual wall switchfor overriding offSL SL SLA few CEFL PIR LRalternativeposition foroptionalwall switch(see p.8“Start-upMode”)load24


PIR OCCUPANCY SWITCHESCost effective, quick and easy to fit PIR occupancy switch designed to fit onto the end oflighting battens.Batten mounted PIR occupancy switchDANLERS Batten mount PIR occupancy switch can be mounted onto the end of lightingbattens via the 20mm knock out. The switch includes the connection 20mm thread and1 metre of wire tails to connect to the lighting ballast.Order code:BMPIRBMPIR fitted on the end of alighting batten.Ideal for use in factories, warehouses, offices, schools etc but also wetrooms, damp areasand outdoor environments such as car parks due to its tough IP66 rated enclosure.Switches lights on when somebody is detected.Switches lights off when nobody has been detected for a chosen period.The photocell can be set so that lights do not switch on during the day.Tough, compact IP66 rated polycarbonate moulding.SpecificationWeatherproof:Detection range:Detection angle: 120°Time lag:Photocell range:Loading:Wiring diagram:Dimensions:IP66 ratingUp to 10m2 to 20 minutes (adjustable)10 lux to infinite lux (adjustable)Up to 6 amps (1500W) incandescent or mains halogen lamps.Up to 4 amps (1000W) electronic or wire wound transformers, fluorescentlamps (high frequency or soft start).Up to 2 amps (500W) compact fluorescent or LED lamps.Up to 1 amp (250W) most fans and metal halide discharge lamps.See diagram 25 below75 x 60 x 37mm plus 1 metre wire tailsDetection diagramSide elevationPlan viewBMPIRBMPIR45°90°60°120°Up to 5mStrongDetectionZoneSecondaryDetectionZoneStrongDetectionZoneSecondaryDetectionZoneUp to 10mDimensions in mmWiring diagramfront60side3725. Single PIR occupancy switch65Loptional manualswitch foroverriding offBMPIRSL20mmthreadedentry spout1024 24N230 VACload25


PIR OCCUPANCY SWITCHES WITH DIMMINGBrings lights on – only when area is occupied. Automatically dims lights accordingto ambient light level to maintain constant brightness of between 100 and 1000 lux(adjustable). Adjustable time lag before switching off. For suspended or plasterboardceilings. Complete with 2m cables for quick and easy installation.PIR occupancy switch with daylight linked dimmingCEFL PIRDD 10VDC is suitable for dimmable ballasts with 1-10VDC input.Order code:CEFL PIRDD 10VDCSpecificationDetection zone: 360°Time lag range: 10 seconds to 40 minutes in 9 stepsPhotocell range: 100 to 1000 lux, falling on the working planeLoading:Total load of ballast, lamps plus other load not more than 6 amps includingfluorescent.Can control up to 20mA, eg. 20 ballasts at 1mA.(Varies according to make and model of ballasts)Wiring diagram: See diagram 26 belowDimensions:72mm diameter x 68mmEnough daylight, Occupied– Lighting OFFReduced daylight, Occupied– Lighting DIMMEDNight, Occupied– Lighting ONEnough daylight, Unoccupied– Lighting OFFReduced daylight,Unoccupied – Lighting OFFNight, Unoccupied– Lighting OFFDetection diagramsPlan Plan view view of detection of detection zone zonePerspective view Perspective of detection viewzoneof detection zoneCovering large areasStrong detection zone i.e. personmoving armSecondary detection zone i.e. personwalking (less sensitive when walkingstraight towards PIR switch)For optimum coveragerecommended mountingheight between 2.4 and 5m.CEFL PIRDD 10VDCStrongdetectionzoneSecondarydetectionzoneTo cover large areas it is advisableto install one CEFL PHDD 10VDCto dim and a few CEFL PIR to switch.Up to 5mUp to 7mPIR Quad detectorgives 124 detectionareas within the zone.Up to 5mUp to 7mDimensions in mmWiring diagramsideplan26. CEFL PIRDD 10VDC controllingseveral 1-10VDC dimmable ballasts662m cables60725533872Requires 63 or 64mm (2.5")diameter hole in a falseor plasterboard ceilingoptional manualwall switch foroverriding offLCEFL PIRDD 10VDCN230 VACSLalternativeposition foroptionalwall switch(see p.8“Start-upMode”)control linesoptionalotherload*1ballast101ballast101ballast10* Total load of ballasts, lamps plus other load not more than 6 amps26


DAYLIGHT LINKED DIMMERSThese automatically dim lights according to ambient light level to maintain a constantbrightness of between 100 and 1000 lux (adjustable). For suspended or plasterboardceilings. Complete with 2m cables for quick and easy installation.Daylight linked dimmersOrder codes:CEFL PHDD 10VDCCEFL DD 10VDCCEFL PHDD 10VDCHas dimming and on/off switching and is suitable for dimmable ballasts with 1-10VDC input.SpecificationPhotocell range: 100 to 1000 lux, falling on the working planeLoading:Total load of ballast, lamps plus other load not more than 6 amps includingfluorescent.Can control up to 20mA, eg. 20 ballasts at 1mA.(Varies according to make and model of ballasts).Wiring diagram: See diagram 28a belowDimensions:72mm diameter x 68mmCEFL DD 10VDCHas dimming only and is suitable for dimmable ballasts with 1-10VDC input.SpecificationPhotocell range: 100 to 1000 lux falling on the working planeLoading:Total load of ballast, lamps plus other load not more than 6 amps includingfluorescent.Can control up to 20mA, eg. 20 ballasts at 1mA.(Varies according to make and model of ballasts).Wiring diagram: See diagram 28b belowDimensions:72mm diameter x 68mmCeiling surface mounted versions: CESF PHDD 10VDC and CESF DD 10VDC are alsoavailable on request.For Manual high frequency dimmers pleasesee pages 50 and 51.Manual wallswitch retained foroverriding OFFEnough daylight– Lighting OFFReduced daylight– Lighting DIMMEDNight– Lighting ONDimensions in mmCEFL PHDD 10VDC and CEFL DD 10VDC66side2m cables6072553plan2472Requires 63 or 64mm (2.5")diameter hole in a falseor plasterboard ceilingWiring diagrams28a. CEFL PHDD 10VDC controllingseveral 1-10VDC dimmable ballastsLNwall switch(optional)CEFL PHDD 10VDC230 VACSLoptionalotherload*control lines1ballast101ballast101ballast10* Total load of ballasts, lamps plus other load not more than 6 amps28b. CEFL DD 10VDC controllingseveral 1-10VDC dimmable ballastsLN230 VACwall switch(compulsary)CEFL DD10VDCcontrol linesSLN1ballast101ballast101ballast1028


DAYLIGHT LINKED DIMMERSAutomatically dims lights according to ambient light level to maintain a constant brightnessof between 100 and 1000 lux (adjustable). For suspended or plasterboard ceilings.Complete with 2m cables for quick and easy installation.Daylight linked dimmersCEFL PHDD DSI has dimming and on/off switching and is suitable for DSI dimmable ballasts.Order code:CEFL PHDD DSISpecificationPhotocell range: 100 to 1000 lux falling on the working planeLoading:Total load of ballast, lamps plus other load not more than 6 amps includingfluorescent.Can control up to 20 DSI ballastsWiring diagram: See diagram 29 belowDimensions:72mm diameter x 68mmFor Manual high frequency dimmers please see pages 50 and 51.Manual wallswitch retained foroverriding OFFEnough daylight– Lighting OFFReduced daylight– Lighting DIMMEDNight– Lighting ONDimensions in mmWiring diagramsideplan29. CEFL PHDD DSI controlling several DSIdimmable ballasts652m cables61725732472Requires 63 or 64mm (2.5")diameter hole in a falseor plasterboard ceilingLCEFL PHDD DSI230 VAC (50Hz)NSLwallswitchoptionalotherload*control linesD1ballastD2D1ballastD2D1ballastD2* Total loadof ballasts,lamps plusother loadnot morethan 6amps29


CEILING PHOTOCELL SWITCHESFor saving lighting energy in offices, factories, sports halls and so on.For flush mounting through suspended or plasterboard ceilings.Complete with 2m cable for quick and easy installation.Ceiling flush-mounted photocell switchesCEFL PHSwitches the lights on when there is not sufficient ambient light available and off whenthere is sufficient ambient light available.Order codes:CEFL PHCEFL PHRECEFL PHREThis ‘Re-set’ version switches the lights off when there is sufficient ambient light butrequires the wall switch to be operated in order to switch on. In this way the lights onlyswitch on when demanded.Built-in differential ensures the artificial lights do not affect the photocell.Built-in time delay of 1 minute avoids unnecessary switching.SpecificationPhotocell range:Loading:Wiring diagram:Dimensions:Switches on at between 100 and 1000 lux falling on theworking planeUp to 6 amps (1500W) of resistive, fluorescentor transformer lighting loadsSee diagram 30 belowCEFL PH and CEFL PHRE: 72mm diameter x 68mmEnough daylight– Lighting OFFNight– Lighting ONManual wallswitch retained foroverriding OFF(and for re-settingCEFL PHRE)Dimensions in mmWiring diagramCEFL PH, CEFL PHRE2m cable66552430. Ceiling photocell switchLmanual wallswitch foroverriding offphotocell switchSL60372230 VACload72Requires 63 or 64mm (2.5")diameter hole in a falseor plasterboard ceilingN30


CEILING PHOTOCELL SWITCHESFor saving lighting energy in offices, factories, sports halls and so on.For surface mounting onto solid ceiling.Ceiling surface-mounted photocell switchesCEPH NOSwitches the lights on when there is not sufficient ambient light available and off whenthere is sufficient ambient light available.Order codes:CEPH NOCEPH RERequires socket, order code:CESO SQ or CESO(see page 17)CEPH REThis ‘Re-set’ version switches the lights off when there is sufficient ambient light butrequires the wall switch to be operated in order to switch on. In this way the lights onlyswitch on when they are demanded.Built-in differential ensures the artificial lights do not affect the photocell.Built-in time delay of 1 minute avoids unnecessary switching.SpecificationCEPH NO and CEPH RE:Photocell range:Loading:Wiring diagram:Dimensions:Plug into CESO SQ Ceiling socket (or CESO Ceiling socket).CESO SQ can be mounted on a square pattress box(or CESO can be mounted on a BESA box).Switches on at between 100 and 1000 lux falling on theworking planeUp to 6 amps (1500W) of resistive, fluorescentor transformer lighting loadsSee diagrams 31a and 31b belowCEPH NO and CEPH RE: 88 x 88 x 47mmCeiling surface mounted versions: CESF NO and CESF PHRE are also availableon request.Enough daylight– Lighting OFFNight– Lighting ONManual wallswitch retained foroverriding OFF(and for re-settingCEPH RE)Dimensions in mmWiring diagramsCEPH NO, CEPH REplan8888side(CESO SQ)4731a. Ceiling photocell switch 31b. Ceiling mounted socket (CESO SQ orCESO) for CEPH NO or CEPH REmanual wallswitch forL Noverriding offphotocell switchLN230 VACSLloadPattressbox orBESAboxL N SLCESO SQor CESOCEPH NO orCEPH REluminaireSLNot to scale31


TIME LAG SWITCHESSelecting the appropriate time lag switch2 wire versionsNo neutral wireneeded3 wire versionsLive, neutral andswitched lineSlaveswitches(normally openpush buttons)Adjustabletime lags:1-10minutes1-120minutes2-20minutes1-120minutes12-120minutes*Exterior:versionsEXTLSWEXTLSW 16ASinglepushbuttonThese electronic time lagswitches are designedto switch lights, or otherloads ON, and thento switch them OFFautomatically after the settime lag has elapsed.Their energy savingbenefits make theseswitches ideal for use instairwells, store roomsand in manyother applications.FunctionsActivated by pressing thepush button or touch pad.The time lag settings canbe adjusted by a spindleon the bottom edge of theproduct. The adjustmentspindle is inside thewaterproof housingsfor the exterior time lagswitches.The interior time lagswitches can be used formulti-way switching usingthe slave push buttons.SingleilluminatedpushbuttonDoublepushbuttonModule forMK GridPlusModule forMK GridPlus,illuminatedpush buttonModule forCrabtreegridModule forCrabtreegrid,illuminatedpush buttonModule forEurodataplatesTLSW 10 TLSW A20 TLSW A120 SS 1SLTLSW 10 ILM TLSW A20 ILM TLSW A120 ILMSS 2SLGRTL MK GRTLA MK SSGS MKGRTL MK ILMGRTLA MK ILMGRTL CB GRTLA CB SSGS CBGRTL CB ILMGRTLA CB ILMGRTL EU GRTLA EU SSGS EUModule forEurodataplates,illuminatedpush buttonModule forDETA andGET gridsGRTL EU ILMGRTLA EU ILMGRTL DT GRTLA DT SSGS DT*TLSW MS is selectablein 4 steps, 1/4 hour, 1/2hour, 1 hour, 2 hours.Multiselectabletime lagswitch*TLSW MS32


TIME LAG SWITCHESExterior time lag switchesOrder code:EXTLSWEXTLSWIdeal for energy saving control of exteriorheaters and exterior lighting. Also suitable fordamp areas indoors.Pressing the button brings the connected load on.The load is then switched off automatically afterthe time lag has elapsed.Illuminated push button for easy location inthe dark.Tough, hard wearing, IP66 rated polycarbonatemoulding.SpecificationThe time lag is adjustable from 2 to 20 minutes.Supply voltage:Weatherproof:230VACIP66 ratingMaximum load: 6 amps (1500W) of resistive load.2 amp (500W) of low energylamps. 1 amp (250W) of fans.Wiring diagram: See diagrams 33a and 33b belowDimensions:90 x 90 x 60mmDimensions in mmCableglandfront9090517side6024 24EXTLSW 16AIdeal for energy saving control of exterior heatersand exterior lighting. Also suitable for damp areasindoors.Pressing the touch sensitive area brings theconnected load on. The load is then switched offautomatically after the time lag has elapsed.Illuminated touch area for easy location inthe dark. Tough, hard wearing, IP66 ratedpolycarbonate moulding.Dimensions in mmfront12024 2490Cable5gland 17side6024Order code:EXTLSW 16ASpecificationThe time lag is adjustable from 2 to 20 minutes.Supply voltage:Weatherproof:Maximum load:230VACIP66 rating16 amps (4000W) of quartzheaters. 12 amps (3000W) offluorescent. 2 amps (500W) ofmost metal halide lampsWiring diagram: See diagrams 33a and 33b belowDimensions:120 x 90 x 60mmWiring diagrams33a. Exterior time lag switchLoptional manualwall switch foroverriding off230 VACExterior timelag switchSLload33b. Several exterior time lag switches wiredin parallelL230 VACexteriortime lagswitchexteriortime lagswitchexteriortime lagswitchSL SL SLNNload33


TIME LAG SWITCHESPlated time lag switches - 2 wire versionsTLSW 10, TLSW 10 ILMNo neutral wire neededDirect replacements for existing wall switches.No neutral wire is needed. Hence they are very quick and inexpensive to install.The TLSW 10 ILM has an illuminated push button for easy location in the dark.Order code:TLSW 10SpecificationThe time lag is adjustable from 1 to 10 minutes.Maximum load:Minimum load:Wiring diagrams:Dimensions:6 amps (1500W) of resistive, fluorescent or transformer lighting loads,or up to 1 amp (250W) of fans40W of resistive, or for wiring in parallel 40W per time lag switch inthe circuit.Load capacitors are now supplied to augment small ornon-resistive loadsSee page 35, diagrams 35a - 35f86 x 86 x 12mmWall box depth 16mmOrder code:TLSW 10 ILMSlave push buttonsThese are normally open (push to make) push buttons. They can be used as slaveswitches to operate a DANLERS time lag switch, as shown in the appropriate wiringdiagrams.SS 1SL is a 1 gang version on a square plate.SS 2SL is a 2 gang version, with 2 push buttons on a square plate.These square plated versions both fit into plaster depth (16mm) wall boxes.Dimensions as below.Also available as grid modules (for dimensions see below):SSGS MK for MK Grid Plus. Minimum wall box depth 35mm.SSGS CB for Crabtree grid. Minimum wall box depth 40mm.SSGS EU for Eurodata plates. Minimum wall box depth 35mm.SSGS DT for DETA and GET grids. Minimum wall box depth 40mm.Dimensions in mmTLSW 10, TLSW 10 ILM,SS 1SL, SS 2SLSSGS MKSSGS CBSSGS EUSSGS DTfront86side12front24side34front24side38front25side38front25side3786593051 3450573234


TIME LAG SWITCHESWiring diagrams - Plated time lag switches - 2 wire versions35a. Single time lag switch with noneutral wire (e.g. TLSW 10)35b. Several TLSW 10 wired in parallele.g. in a stairwell35c. TLSW 10 with slave push buttonsLtime lag switchSLLtime lagswitchtime lagswitchtime lagswitchLtime lag switchSL230 VAC230 VACSL SL SL230VACNloadNloadNslave switches (normallyopen push buttons)loadCircuit diagrams - Plated time lag switches - 2 wire versions into 2-way circuitThe circuit diagrams oppositeillustrate a 2-way wiringconfiguration typical of those foundon location. They also demonstratehow DANLERS Plated time lagswitches (2-wire versions) andDANLERS Slave switches can beincorporated.35d. Existing 2-way circuitSLloadL230 VACNThese circuit diagrams use the BS7671:2001 harmonised colour codingwith the triple-and-earth colours ofbrown, black and grey for the lines.For clarity all earth wires are omitted.They show the physical connectionswith • or •• as appropriate.They use brown and blue for the lineand neutral feeds to the circuit.They use twin-brown and earth forthe feed to the first 2-way switch.Any unused wires are terminatedwith the x symbol.NOTE:These circuits are onlyrecommendations and thecontractor remains responsiblefor their own work.35e. Time lag switches with no neutral wire, wired in parallel (minimum load restrictions apply).To achieve minimum load restriction, supplement one load capacitor (CAPLOAD) per TLSW 10 (ILM) asshown below.LSLload230 VACNLSLTime lag switchLoad capacitor(s)if required35f. Time lag switch with no neutral wire, with slave push buttons (minimum loadrestrictions apply).To achieve minimum load restriction, supplement one load capacitor (CAPLOAD) as shown below.LTime lagswitchSLSLTime lagswitchAs an alternative wiring method to avoid minimumload restrictions use “3 wire” Time lag switches(eg. TLSW A20), by using the spare strapper as aneutral (see circuit diagram 37e, page 37).LLSLPBPBPBSLPBTime lag switchPBSlaveswitchPBSlaveswitchloadL N230 VACLoad capacitorPB = Slave push button connectionsAs an alternative wiring method to avoid minimumload restrictions use a “3 wire” Time lag switch(e.g. TLSW A20), by linking a neutral to the Time lagswitch (see circuit diagram 37f, page 37).35


TIME LAG SWITCHESPlated time lag switches - 3 wire versionsThese 3 wire versions are economical switches which need neutral wires.The TLSW A20 ILM and TLSW A120 ILM have illuminated push buttons for easy locationin the dark.Order codes:TLSW A20TLSW A120SpecificationThe time lags are adjustable:TLSW A20:TLSW A20 ILM:TLSW A120:TLSW A120 ILM:Loading:Wiring diagrams:Dimensions:2 to 20 minutes2 to 20 minutes12 to 120 minutes12 to 120 minutesUp to 6 amps (1500W) of resistive, fluorescent or transformer lightingloads, or up to 1 amp (250W) of fans. No minimum loadSee page 37, diagrams 37a - 37f86 x 86 x 12mm. Wall box depth 16mmOrder codes:TLSW A20 ILMTLSW A120 ILMSlave push buttonsThese are normally open (push to make) push buttons. They can be used as slaveswitches to operate a DANLERS time lag switch, as shown in the appropriate wiringdiagrams.SS 1SL is a 1 gang version on a square plate.SS 2SL is a 2 gang version, with 2 push buttons on a square plate.These square plated versions both fit into plaster depth (16mm) wall boxes.Dimensions as below.Also available as grid modules (for dimensions see below):SSGS MK for MK Grid Plus. Minimum wall box depth 35mm.SSGS CB for Crabtree grid. Minimum wall box depth 40mm.SSGS EU for Eurodata plates. Minimum wall box depth 35mm.SSGS DT for DETA and GET grids. Minimum wall box depth 40mm.Dimensions in mmTLSW A20, TLSW A120,TLSW A20 ILM, TLSW A120 ILM,SS 1SL, SS 2SLfrontsideSSGS MKfront24side34SSGS CBfront24side38SSGS EUfront25side38SSGS DTfront25side37861286593051 3450573236


TIME LAG SWITCHESWiring diagrams - Plated time lag switches - 3 wire versions37a. Single time lag switch withneutral wire (e.g. TLSW A20)37b. Several time lag switches withneutral wires, wired in parallel37c. Time lag switch with neutral wire,with slave push buttonsLtime lag switchSLLtime lagswitchtime lagswitchtime lagswitchLtime lag switchSL230 VAC230 VACSL SL SL230 VACNloadNloadNslave switches (normallyopen push buttons)loadCircuit diagrams - Plated time lag switches - 3 wire versions into 2-way circuitThe circuit diagrams oppositeillustrate a 2-way wiringconfiguration typical of those foundon location. They also demonstratehow DANLERS Plated time lagswitches (3-wire versions) andDANLERS Slave switches can beincorporated.NOTE: Circuit diagrams 37d and 37eare also applicable to Grid time lagswitches (3 wire versions), see pages40 and 41.37d. Existing 2-way circuitSLloadL N230 VACThese circuit diagrams use the BS7671:2001 harmonised colour codingwith the triple-and-earth colours ofbrown, black and grey for the lines.For clarity all earth wires are omitted.They show the physical connectionswith • or •• as appropriate.They use brown and blue for the lineand neutral feeds to the circuit.They use twin-brown and earth forthe feed to the first 2-way switch.Any unused wires are terminatedwith the x symbol.NOTE:These circuits are onlyrecommendations and thecontractor remains responsiblefor their own work.37e. Time lag switches with neutral wire, wired in parallel (no minimum load)LloadSL230 VACNLTime lagswitchSLN37f. Time lag switch with neutral wire, with slave push buttons (no minimum load)LTime lagswitchSLNSLNTime lagswitchLLSLPBPBPBSLNTime lagswitchPBSlaveswitchPBPBSlaveswitchloadPB = Slave push button connectionsL230 VACN37


TIME LAG SWITCHESThese time lag switches are in grid module formats.Grid time lag switches - 2 wire versionsFor MK Grid PlusOrder codes:GRTL MK, GRTL MK ILMFor Crabtree gridOrder codes:GRTL CB, GRTL CB ILMDANLERS manufacture four versions, to suit each of the following formats, MK Grid Plus,Crabtree grid, Eurodata plates, Deta and GET grids. They may be placed in any positionon the appropriate grid or plate.These Grid time lag switches can be operated by slave push buttons, as listed on page36 (see wiring diagrams 39b and 39e opposite).The GRTL MK ILM, GRTL CB ILM and GRTL EU ILM have illuminated push buttons foreasy location in the dark.SpecificationTime lag:1 to 120 minutes (adjustable)Maximum load: 6 amps (1500W) of resistive, fluorescent or transformer lighting loads, orup to 1 amp (250W) of fansMinimum load:2W of resistive.A load capacitor (order code CAPLOAD) can be supplied to augmentsmall or non-resistive loadsWiring diagrams: See page 39, diagrams 39a-39eDimensions:Dimensions:Dimensions:Dimensions:Module for MK Grid Plus: 59 x 24 x 34mm.Minimum wall box depth 35mmModule for Crabtree grid: 51 x 24 x 38mm.Minimum wall box depth 40mmModule for Eurodata plates: 50 x 25 x 38mm.Minimum wall box depth 35mmModule for Deta and GET grids: 57 x 25 x 37mm.Minimum wall box depth 40mmFor Eurodata platesOrder codes:GRTL EU, GRTL EU ILMMK Grid Plus Crabtree Grid Eurodata plateDeta gridFor Deta andGET gridsOrder codes:GRTL DTDimensions in mmGRTL MK, GRTL MK ILM,SSGS MKRequires wall box depthof 35mmfront24GRTL CB, GRTL CB ILM,SSGS CBRequires wall box depthof 40mmGRTL EU, GRTL EU ILM,SSGS EURequires wall box depthof 35mmsidefrontsidefrontside34 24382538GRTL DT, SSGS DTRequires wall box depthof 40mmfront25side37593051 3450573238


TIME LAG SWITCHESThese time lag switches are in grid module formats.Grid time lag switches - 3 wire versionsFor MK Grid PlusOrder codes:GRTLA MK, GRTLA MK ILMFor Crabtree gridOrder codes:GRTLA CB, GRTLA CB ILMDANLERS manufacture four versions, to suit each of the following formats, MK Grid Plus,Crabtree grid, Eurodata plates, Deta and GET grids. They may be placed in any positionon the appropriate grid or plate.These Grid time lag switches can be operated by slave push buttons, as listed on page36 (see wiring diagrams 41b opposite and 37d and 37e on page 37).The GRTLA MK ILM, GRTLA CB ILM and GRTLA EU ILM have illuminated push buttonsfor easy location in the dark.SpecificationTime lag:1 to 120 minutes (adjustable)Maximum load: 6 amps (1500W) of resistive, fluorescent or transformer lighting loads, orup to 1 amp (250W) of fans.Minimum load:2W of resistive.A load capacitor (CAPLOAD) can be supplied to augment small loadssuch as contactors, low energy lamps, LEDs and emergency light fittingsWiring diagrams: See page 41, diagrams 41a and 41b, also see page 37, diagrams 37dand 37eDimensions:Dimensions:Dimensions:Dimensions:Module for MK Grid Plus: 59 x 24 x 34mm.Minimum wall box depth 35mmModule for Crabtree grid: 51 x 24 x 38mm.Minimum wall box depth 40mmModule for Eurodata plates: 50 x 25 x 38mm.Minimum wall box depth 35mmModule for Deta and GET grids: 57 x 25 x 37mm.Minimum wall box depth 40mmFor Eurodata platesOrder codes:GRTLA EU, GRTLA EU ILMMK Grid Plus Crabtree Grid Eurodata plateDeta gridFor Deta andGET gridsOrder codes:GRTLA DTDimensions in mmGRTLA MK,GRTLA MK ILMRequires wall box depthof 35mmfront24side34GRTLA CB,GRTLA CB ILMRequires wall box depthof 40mmfront24side38GRTLA EU,GRTLA EU ILMRequires wall box depth of35mmfront25side38GRTLA DTRequires wall box depthof 40mmfront25side37593051 3450573240


TIME LAG SWITCHESWiring diagrams - Grid time lag switches - 3 wire versions41a. Single grid time lag switch withneutral wire (e.g. GRTLA MK)Lgrid time lagswitchSL41b. Several grid time lag switcheswith neutral wires, wired in parallelLgridtime lagswitchgridtime lagswitchgridtime lagswitchSee page 37 for circuit diagrams 37dand 37e of Grid time lag switches(3 wire versions) into a 2-way circuit.230 VAC230 VACSL SL SLloadNNloadMulti-selectable time lag switchFor multi-selectable control of electric loads (including heating loads).Switches load on for a limited time only. Pressing the button selects each time lag choicein turn.The load then remains on for the chosen time lag before switching off automatically.The button can also be used at any time for selecting a different time lag or forswitching off.Bespoke versions are available on request.Order code:TLSW MSSpecificationSelectable time lag:Loading:Wiring diagram:Dimensions:1/4 hour, 1/2 hour, 1 hour, 2 hoursUp to 13 amps (3000W) of resistive load,or 6 amps (1500W) of transformer loadSee diagram 41c below86 x 86 x 12mm.Wall box depth: 25mmA Heater boost switch (order code: TLSW HB) is also available, see page 53 for details.Dimensions in mmTLSW MSWiring diagram41c. Multi-selectable time lag switchfront86side12LTLSW MS86230 VACloadNN41


OUTDOOR SECURITY SWITCHESAn outdoor PIR switch which turns on lights at night when somebody approaches.Welcomes friends and deters intruders. Ideal for security and convenience. A compactdesign for controlling new or existing outdoor lights.Compact person detectorFunctions and featuresSwitches lights on when somebody is detected.Switches lights off when nobody has been detected for a chosen period.The photocell can be set so that lights do not switch on during the day.Compact polycarbonate moulding.Order code:COPDSpecificationWeatherproof:Detection range:Detection angle: 120°Time lag:Photocell range:Loading:Wiring diagram:Dimensions:IP54 ratingUp to 10m2 to 20 minutes (adjustable)10 lux to infinite lux (adjustable)Up to 6 amps (1500W) incandescent or mains halogen lamps.Up to 4 amps (1000W) electronic or wire wound transformers, fluorescentlamps (high frequency or soft start).Up to 2 amps (500W) compact fluorescent or LED lamps.Up to 1 amp (250W) most fans and metal halide discharge lamps.See diagram 42 below75 x 60 x 37mmA version without a photocell is also available on request (order code: COPD XPH).Dimensions in mmWiring diagramDetection diagram42. COPD outdoor PIR switchExterior wall mounted PIR switchRecommended mounting height between 1 and 2.2mfrontside603720mmthreadedentry spout651024 24LNoptional manualswitch foroverriding off230 VACCOPDSLloadStrongdetection zone(5m)Secondarydetection zone(10m)42


OUTDOOR SECURITY SWITCHESTwilight and Dusk switchesTwilight switch: TWSWSwitches outdoor lights on at dusk and off at dawn. Ideal for all night security.FeaturesAdjustable photocell.Compact polycarbonate moulding.Vandal resistant.Order code:TWSWSpecificationWeatherproof:Photocell range:Loading:Wiring diagram:Dimensions:IP54 rating10 lux to 300 lux (adjustable)Up to 6 amps (1500W) incandescent or mains halogen lamps.Up to 4 amps (1000W) electronic or wire wound transformers, fluorescentlamps (high frequency or soft start).Up to 2 amps (500W) compact fluorescent or LED lamps.Up to 1 amp (250W) most fans and metal halide discharge lamps.See diagram 43 below75 x 60 x 37mmDusk switch: DUSWSwitches lights on at dusk and off after a chosen period.Ideal for outdoor lighting during the evening, for security and convenience.FeaturesAdjustable photocell.Adjustable time lag before switching off.Compact polycarbonate moulding.Vandal resistant.Order code:DUSWSpecificationWeatherproof:Photocell range:Time lag:Loading:Wiring diagram:Dimensions:IP54 rating10 lux to 300 lux (adjustable)2 to 16 hours (adjustable)Up to 6 amps (1500W) incandescent or mains halogen lamps.Up to 4 amps (1000W) electronic or wire wound transformers, fluorescentlamps (high frequency or soft start).Up to 2 amps (500W) compact fluorescent or LED lamps.Up to 1 amp (250W) most fans and metal halide discharge lamps.See diagram 43 below75 x 60 x 37mmDimensions in mmWiring diagramTWSW Twilight switchfront6065side37DUSW Dusk switch17510frontside24 24Cablegland43. Outdoor photocell switches TWSWor DUSWLoptional manualswitch foroverriding offDANLERS controlSL20mmthreadedentry spout1024 24656037N230 VACload43


TRAILING EDGE DIMMERSQuiet grid dimmer modulesThese dimmers can be used to dim lights from several locations. They aresuitable for dimming mains and/or dimmable transformer low voltage lamps.Functions and Special featuresSlim buttons give an easy press action. Pressing the button dimsor brightens the light to any level. A quick press switches off. Anotherpress returns the lamp to its previous brightness.All versions are suitable for dimming most mains dimmableLED lamps and fittings and mains halogen (e.g. GU10) lamps.Quiet operation.The soft start feature prolongs the lamp life.Some LED lamps may require a small resistive load(order code RESLOAD) to enable smooth dimming.For an up to date list of LED lamps and fittings tested with DANLERSdimmers, please visit the DANLERS website www.danlers.co.ukMulti-way switching and dimming can be achieved from any positiononly by using the complementary DANLERS slave switches.These grid dimmer modules fit any position on the appropriate grid orplate system.D I M MMULTIL E DD I M MI N GPOINTQUIETI N GO P E R AT I O NDimensions in mmDimmer module for MK GridPlus.front24side34Dimmer module forCrabtree grid.front24side38Dimmer module for Eurodataplates.front25side38Dimmer module for Deta andGET grids.front25side37593051 3450573244


TRAILING EDGE DIMMERSQuiet grid dimmer modulesOrder codeMin. and Max. wattageResistive, mains halogenor dimmable electronictransformer loadsMin. and Max. wattageDimmable wire-woundor toroidal transformerinductive loadsMin. andMax. wattageLED lampsand fittings*Wallboxdepth(mm)DQDGD MK400W 10 – 400W Not suitable 10 – 200W* 35DQDGD CB400W 10 – 400W Not suitable 10 – 200W* 40DQDGD EU400W 10 – 400W Not suitable 10 – 200W* 35DQDGD DT400W 10 – 400W Not suitable 10 – 200W* 40For MK Grid PlusOrder code:DQDGD MK400W* Can vary depending LED lamp characteristics.For loading of Grid dimmers on multi-gang plates the following limits also apply:2 gang plates: Maximum for total plate – 630W3 or 4 gang plates: Maximum for total plate – 1000W6, 8, 9 or 12 gang plates: Maximum per row – 1000W18 or 24 gang plates: Maximum per row – 1200WDimensionsModule for MK Grid Plus:Module for Crabtree grid:Module for Eurodata plates:Module for Deta and GET grids:59 x 24 x 34mm, minimum wall box depth of 35mm51 x 24 x 38mm, minimum wall box depth of 40mm50 x 25 x 38mm, minimum wall box depth of 35mm57 x 25 x 37mm, minimum wall box depth of 40mmFor Crabtree gridOrder code:DQDGD CB400W2-wire and intermediate wiring can be used with DANLERS Quiet grid dimmers(see page 47) however all 2-way and intermediate switches must be changed toDANLERS Slave switches SSGS_ _ or SS_SL.Wiring diagrams45a. Example of an existing 2-way circuit45b. Replace the 2-way switches with aDimmer and a Slave, as shownLLS VdimmerFor Eurodata platesOrder code:DQDGD EU400W230 VACload230 VAC DANLERSslaveswitchloadNN45c. Multi-way switching and dimming(lights can be switched and dimmedfrom any position)LS Vdimmer230 VACDANLERSslaveswitchDANLERSslaveswitchloadFor Deta and GET gridsOrder code:DQDGD DT400WN45


LEADING EDGE DIMMERSSoft start dimmersOrder codes:DSS1D 250W, DSS1D 400WThese dimmers can be used to dim lights from several locations.They are suitable for dimming resistive lamps, dimmable transformerlow voltage lamps.FunctionsSlim buttons give an easy press action. Pressing the button dims orbrightens the light to any level. A quick press switches off. Anotherpress returns the lamp softly to its previous brightness. These dimmerscan also be used to control the speed of fans and motors.Special FeaturesAll versions are suitable for mains halogen* (e.g. GU10) lamps without the needfor derating. *Mains halogen lamps must have an integral thermal safety fuse.The soft start feature prolongs the lamp life.Multi-way switching and dimming can be achieved from any position only by using thecomplementary DANLERS slave switches (see page 47).The grid module versions fit any position on the appropriate grid or plate system.These dimmers automatically switch off in the event of transformer malfunction, helping toprotect the dimmer and the transformer.DimensionsSquare plates:Module for MK Grid Plus:Module for Crabtree grid:Module for Eurodata plates:Module for Deta and GET grids:MULTID I M MPOINT86 x 86 x 12mm, see table below for wall box depths59 x 24 x 34mm, minimum wall box depth of 35mm51 x 24 x 38mm, minimum wall box depth of 40mm50 x 25 x 38mm, minimum wall box depth of 35mm57 x 25 x 37mm, minimum wall box depth of 40mmI N GOrder codes:DSS2D 250WOrder codeMin. and Max. wattageResistive, mains halogenor dimmable electronictransformer loadsMin. and Max. wattageDimmable wire-woundor toroidal transformerinductive loadsMax. No.of transformersWallboxdepth(mm)DSS1D 250W 40 – 250W 40 – 160W 4 16DSS1D 400W 60 – 400W 60 – 250W 6 16DSS2D 250W 40 – 250W /gang 40 – 160W /gang 4/gang 16DSSGD MK400W 40 – 400W 40 – 250W 6 35DSSGD CB400W 40 – 400W 40 – 250W 6 40DSSGD EU400W 40 – 400W 40 – 250W 6 35For MK Grid Plus (above left)DSSGD MK400WFor Crabtree grid (above right)DSSGD CB400WDSSGD DT400W 40 – 400W 40 – 250W 6 35For loading of Grid dimmers on multi-gang plates the following limits also apply:2 gang plates: Maximum for total plate – 630W3 or 4 gang plates: Maximum for total plate – 1000W6, 8, 9 or 12 gang plates: Maximum per row – 1000W18 or 24 gang plates: Maximum per row – 1200WWiring diagrams: See diagrams 47a - 47d on page 47Dimensions in mmSquare plated dimmer switches(1 gang switch illustrated)Lights can be switched AND dimmed fromseveral locations.frontsideFor Eurodata plates (above left)DSSGD EU400W,8612For Deta and GET grids (above right)DSSGD DT400W8646


DIMMERSWiring diagrams - Quiet dimmers and Soft start dimmers (plated and grid)2-WAY CIRCUITINTERMEDIATE CIRCUIT47a. Existing 2-way circuit47e. Existing intermediate circuitLSLLSL230 VAC230 VACNloadNload47b. Dimming circuits with 2-way switching and dimming47f. Dimming circuits with multi-way switching and dimmingL230 VACslaveLSLSVdimmerL230 VACslaveLSslaveLSLVS dimmerNloadNloadALTERNATIVE 2-WAY CIRCUIT47c. Existing alternative 2-way circuitLALTERNATIVE INTERMEDIATE CIRCUIT47g. Existing alternative intermediate circuitL230 VAC230 VACNloadSLNSLload47d. Alternative dimming circuits with 2-way switchingand dimming47h. Alternative dimming circuits with multi-way switchingand dimmingLN230 VACLVSdimmerSDANLERSslaveswitchLNdimmer L230 VACSVLSDANLERSslaveswitchLSDANLERSslaveswitchloadloadSlave push buttonsThese are normally open (push to make) push buttons. They can be used as slaveswitches to operate a DANLERS Soft start dimmer, as shown in the appropriate wiringdiagrams.SS 1SL is a 1 gang version on a square plate.SS 2SL is a 2 gang version, with 2 push buttons on a square plate.These square plated versions both fit into plaster depth (16mm) wall boxes.Dimensions as below.Also available as grid modules (for dimensions see below):SSGS MK for MK Grid Plus. Minimum wall box depth 35mm.SSGS CB for Crabtree grid. Minimum wall box depth 40mm.SSGS EU for Eurodata plates. Minimum wall box depth 35mm.SSGS DT for DETA and GET grids. Minimum wall box depth 40mm.47


LEADING EDGE DIMMERSRotary and push dimmersA range of dimmers with elegant styling. Dim lights to any brightness.Versions are available for tungsten loads and dimmable low voltage transformer loads.All versions are suitable for mains halogen* (e.g. GU10) lamps without theneed for derating.*Mains halogen lamps must have an integral thermal safety fuse.SpecificationMaterial:Rotary dimmers:Push dimmers:Dimensions:White polycarbonateRotary on/off switching, rotary dimming control. 1 way onlyPush on, push off, with rotary dimming control. 1 or 2 way switchingSquare plates: 86 x 86 x 12mm, see belowSee tables on page 49 for wall box depthsRectangular plates: 146 x 86 x 12mm, see belowSee tables on page 49 for wall box depthsDimensions in mmSquare plated dimmer switches(1 gang switch illustrated)Rectangular plated dimmer switches(4 gang switch illustrated)frontsidefrontside861214612868648


LEADING EDGE DIMMERSRotary and push dimmersTungsten rotary dimmers, 1 waySuitable for resistive loads.Suitable for mains halogen lamps* without the need for derating.*Mains halogen lamps must have an integral thermal safety fuse.Number ofgangsOrder codeMin. and Max. wattageMax. No. oftransformers1 DR1D 250W 40 – 250W - 161 DR1D 400W 60 – 400W - 162 DR2D 250W 40 – 250W/gang - 16Wall boxdepth (mm)Tungsten push dimmers, 2 waySuitable for resistive loads.Suitable for mains halogen lamps* without the need for derating.*Mains halogen lamps must have an integral thermal safety fuse.1 DP1D 250W 40 – 250W - 161 DP1D 400W 60 – 400W - 161 DP1D 630W 60 – 630W - 401 DP1D 1000W 100 – 1000W - 252 DP2D 250W 40 – 250W/gang - 163 DP3D 250W 40 – 250W/gang - 164 DP4D 250W 40 – 250W/gang - 16Low voltage push dimmers, 2 wayFor dimmable wire-wound transformer inductive loads.1 DP1D 250WI 60 – 250W 6 161 DP1D 400WI 60 – 400W 8 401 DP1D 630WI 60 – 630W 12 252 DP2D 160WI 40 – 160W/gang 4/gang 16Low voltage push dimmers, 2 wayFor dimmable electronic transformer loads.1 DP1D 250WIET 40 – 250W 4 161 DP1D 400WIET 60 – 400W 6 161 DP1D 630WIET 60 – 630W 8 401 DP1D 1000WIET 60 – 1000W 12 252 DP2D 250WIET 40 – 250W/gang 4/gang 163 DP3D 250WIET 40 – 250W/gang 4/gang 164 DP4D 250WIET 40 – 250W/gang 4/gang 16Push switch, 2 wayOn/off switch to match Rotary and push dimmer range. 1 or 2 way switching.1 DP1S 1500W 0 - 1500W N/A 1649


MANUAL HIGH FREQUENCY DIMMERSHigh frequency controllers (plated)Push on, push-off, with rotary dimming control.SpecificationDP1D 10VDC SB: For one or two dimmable ballasts with 1-10VDC inputWiring diagram:Loading:Dimensions:See diagram 50a belowTotal load of ballast, lamps plus other load not more than 6 amps includingfluorescent.86 x 86 x 12mm. Wall box depth 16mmOrder codes:DP1D 10VDC SBDP1D 10VDC MBDP1D DSIDP1D 10VDC MB: For multiple dimmable ballasts with 1-10VDC inputWiring diagram:Loading:Dimensions:See diagram 50b belowTotal load of ballast, lamps plus other load not more than 6 amps includingfluorescent.Can control up to 20mA, eg. 20 ballasts at 1mA.(Control current of ballast is usually specified at 1-10V terminals.)86 x 86 x 12mm. Wall box depth 16mmDP1D DSI:Wiring diagram:Loading:Dimensions:For multiple DSI dimmable ballastsSee diagram 50c belowTotal load of ballast, lamps plus other load not more than 6 amps includingfluorescent.Can control up to 20 DSI ballasts86 x 86 x 12mm. Wall box depth 35mm.Dimensions (in mm) and wiring diagramsDP1D 10VDC SB, DP1D 10VDC MB,DP1D DSIfront86side1250a. DP1D 10VDC SB dimming a single 1-10VDC ballast(optional multi-way switching illustrated)LOptional2-wayswitchOptionalintermediateswitch(es)L1L2SLDP1D 10VDC SBcontrol lines1ballast1086N230 VACoptionalotherload** Total load of ballast(s), lamps plus other load not more than 6 amps50b. DP1D 10VDC MB dimming several 1-10VDC ballasts(optional multi-way switching illustrated)LNOptional2-wayswitch230 VAC50c. DP1D DSI dimming several DSI ballasts (optional multi-wayswitching illustrated)Optionalintermediatecontrol linesOptionalswitch(es)2-way switchL1L1SLLL2L21ballastOptionalDP1D 10VDC MB10DP1D DSIintermediate1switch(es)ballast230 VAC10optionalother1load*ballastN10* Total load of ballasts, lamps plus other load not more than 6 ampsSLoptionalotherload*control linesD1ballastD2D1ballastD2D1ballastD2* Total load of ballasts, lamps plus other load not more than 6 amps50


MANUAL HIGH FREQUENCY DIMMERSHigh frequency controllers (grid modules)Suitable for dimmable ballasts with 1-10VDC input. Push on, push off, hold to dim.Versions to suit the MK Grid Plus, Crabtree grid, Eurodata plates, Deta and GET grids.They may be placed in any position on the appropriate grid or plate.They can also be operated by additional mains rated, normally open retractive switches.Please call for details.For MK Grid PlusOrder code:DSSGD MK 10VDCSpecificationWiring diagram:Loading:Dimensions:See diagram 51 belowTotal load of ballast, lamps plus other load not more than 6 amps includingfluorescent.Can control up to 20mA, eg. 20 ballasts at 1mA.When controlling LED drivers a load capacitor (order code CAPLOAD) maybe required to augment the loadModule for MK Grid Plus: 59 x 24 x 34mm.Minimum wall box depth 35mmModule for Crabtree grid: 51 x 24 x 38mm.Minimum wall box depth 40mmModule for Eurodata plates: 50 x 25 x 38mm.Minimum wall box depth 35mmModule for Deta and GET grids: 57 x 25 x 37mm.Minimum wall box depth 40mmFor Crabtree gridOrder code:DSSGD CB 10VDCDimensions (in mm) and wiring diagramDSSGD MK 10VDCRequires wall box depth of 35mmfront24side34DSSGD CB 10VDCRequires wall box depth of 40mmfront24side38593051 34For Eurodata platesOrder code:DSSGD EU 10VDCDSSGD EU 10VDCRequires wall box depth of 35mmfront2550side38DSSGD DT 10VDCRequires wall box depth of 40mmfront255732side37For Deta and GET gridsOrder code:DSSGD DT 10VDC51. DSSGD MK 10VDC, DSSGD CB 10VDC, DSSGD EU 10VDC, DSSGD DT 10VDC dimmingseveral 1-10VDC ballastsLNOptionalmains rated,normally openpush button(s)230 VACLNHigh frequency griddimmer moduleRSLoptionalother load*control lines1ballast101ballast101ballast10* Total load of ballasts,lamps plus other loadnot more than 6 amps51


HVAC CONTROLS (for Heating, Ventilation and Air Conditioning)PIR thermostat controlsOrder code: WAPIR THPIR thermostat control for heating: WAPIR TH (user adjustable)PIR thermostat control for heating: WAPIR THX (hidden adjustment)For the automatic control of electric heating loads. The passive infra-red person detectordetects whether somebody is present in the vicinity. If somebody is present the heating iscontrolled by the thermostat. If nobody is present the room temperature is allowed to dropto a lower base level. This base level or ‘set-back temperature’ is also adjustable.WAPIR TH has an adjustable front thermostat dial.WAPIR THX does not have an adjustable front dial. The thermostat setting is adjusted to thepreferred setting by use of a spindle on the back of the product.For wall mounting only.SpecificationDetection angle: 120°, see page 21 (as WAPIR)Thermostat range: 15 to 25ºCSet-back temperature: 5 to 14ºCLoading:Up to 13 amps (3000W) of any type of resistive heating loadWiring diagram: See diagram 52 belowDimensions:86 x 86 x 22mm. Wall box depth: 25mmOrder code: WAPIR THXOrder code: WAPIR TCPIR thermostat control for cooling: WAPIR TC (user adjustable)PIR thermostat control for cooling: WAPIR TCX (hidden adjustment)For the automatic control of electric cooling loads. The passive infra-red person detectordetects whether somebody is present in the vicinity. If somebody is present the coolingis controlled by the thermostat. There is a ‘deadzone’ adjustment and a run-on timeadjustment to avoid excessive switching of the cooling load. If nobody is present the coolingthermostat remains off until the room temperature reaches its upper threshold. This upperthreshold is set using the ‘offset’ temperature adjustment.WAPIR TC has an adjustable front thermostat dial.WAPIR TCX does not have an adjustable front dial. The thermostat setting is adjusted to thepreferred setting by use of a spindle on the back of the product.For wall mounting only.SpecificationDetection angle:Thermostat range: 15 to 25ºCOffset temperature:120°, see page 21 (as WAPIR)Deadzone adjustment: 1, 2, 3, 4 or 5ºCRun-on time:Loading:Wiring diagram:Dimensions:Differential of 2 to 10ºC above main thermostat setting or disabled0 minutes or 5 minutesUp to 13 amps (3000W) of any type of resistive cooling loadSee diagram 52 below86 x 86 x 22mm. Wall box depth: 25mmOrder code: WAPIR TCXDimensions in mmWAPIR TH, WAPIR THX, WAPIR TC,WAPIR TCXfrontside8622Wiring diagram52. PIR Thermostat controlling a heating orcooling loadLDANLERS controlSL86230 VACloadNN52


HVAC CONTROLS (for Heating, Ventilation and Air Conditioning)Heater boost switchOrder code: TLSW HBFor control of electric heating loads (or other electric loads). Switches heating load on for alimited time only. Pressing the button selects each time lag choice in turn. The heating thenremains on for the chosen time lag before switching off automatically. The button can alsobe used at any time for selecting a different time lag or for switching off.Bespoke versions are available on request.SpecificationSelectable time lag:Loading:Wiring diagram:Dimensions:1/4 hour, 1/2 hour, 1 hour, 2 hoursUp to 13 amps (3000W) of resistive load,or 6 amps (1500W) of transformer loadSee diagram 53a below86 x 86 x 12mm. Wall box depth: 25mmA Multi-selectable time lag switch (TLSW MS) is also available, see page 41 for details.Fan speed controlControls the speed of fans and small motors. Push-on, push-off with rotary speed control.Can be used in one or two way switching circuits. Not suitable for control of fans or motorswhich are synchronous (designed to be constant speed).Order code: FASPSpecificationMinimum load:Maximum load:Wiring diagram:Dimensions:40W250WSee diagrams 53b and 53c below86 x 86 x 12mm. Wall box depth: 16mmDimensions in mmTLSW HBFASPfrontsidefrontside861286128686Wiring diagrams53a. Heater boost switch controlling aheating load53b. Fan speed control in 1-wayswitching circuit53c. Fan speed control in 2-wayswitching circuitLTLSW HBSLLFASPVLFASPV230 VAC230 VAC230 VACloadloadloadNNNN53


RADIO REMOTE CONTROLSThese products are used for the remote control switching or dimming of lighting or other loads. The wire-free senders are availableas hand held or wall mounted versions.A receiver switch or receiver dimmer is wired into the existing circuit to control the connected load. The sender signals canpass through walls or ceilings so the receivers can be mounted out of sight. Inside a typical building the receivers can work atan approximate range of 30-50 metres. In free air the range is approximately 100-150 metres. The carrier frequency of the radiosignals is 868MHz, which is CE Approved and Licence Free.AN EXAMPLE BUILDINGRadio receiversExterior receiver switchfor outside lights.Radio remote control senders and receiversDisplay cabinet lamps orstandard desk lamps canbe controlled via a plug-indimmer receiver.Receiver switches andreceiver dimmers for thelighting circuits canbe concealed behind afalse ceiling.Wire-free radio senders12 channel hand sender to controlceiling lights, spot lights and screen.For security reasons a caretaker canuse another 12 channel hand sender tocontrol all the lights inside the buildingand the outside security lights.All lights can also becontrolled by wire-freewall mounted senders.54


RADIO REMOTE CONTROLSRadio remote control functionsEach button on each sender sends a unique coded signal (one of 4 billion codes).A simple set-up procedure enables any chosen receiver to respond to the signal from anychosen sender button. The sender button then controls the receiver (and its connectedload). This simple procedure is repeated, creating links between various sender buttonsand various receivers.As shown, almost any control set-up is possible; from a single room to an entire building.For the simplestset-up, onereceiver can becontrolled by onesender.ReceiverSenderAny receiver canbe programmed torespond to the uniquecoded signal fromany sender button.Hence, a senderbutton can control anynumber of receiverssimultaneously.Also a single receiver can be controlled by up to 15sender buttons.These control combinations can be mixed and matched, makingit possible to have almost any control set-up desired; from thesimplest single room to an entire building.In the above control set-up, one button on the left hand sendercontrols the first receiver. A different button on the left handsender controls the first and second receivers simultaneously,and so on.Typical penetration of radio signalsThe radio signals cannot pass throughthe entire length of walls.The radio signals achieve a range ofapproximately 30-50m inside a building;100-150m in free air.Brick walls:approx. 60-90%penetrationTimberframeworkwith sandwichplasterboards:approx. 80-95%penetrationReinforcedconcrete:approx. 20-60%penetrationMetal walls:approx. 0-10%penetrationConventionalglass: approx.70-90%Insulating glass(with vaporisedmetal coat):approx. 30-60%penetrationPlastics:approx. 80-95%penetration55


RADIO REMOTE CONTROLSRadio remote control wire-free hand sendersOrder code: HASE 12RF12 channel hand held senderSends on 12 unique channels.Complete with two AAA batteries.SpecificationSignal range:Carrier frequency:Dimensions:Up to 150m in free air868MHz (CE Approved,Licence Free)120 x 57 x 24mmDimensions in mmfront57120side241 channel hand held senderSends on 1 unique channel.Complete with CR2430 battery.SpecificationSignal range:Carrier frequency:Dimensions:Up to 100m in free air868MHz (CE Approved,Licence Free)100 x 61 x 21mmDimensions in mmfront61100side21Order code: HASE 1RF2 channel key fob senderSends on 2 unique channels.Complete with CR2430 battery.With optional wall mounting fixing.SpecificationSignal range:Carrier frequency:Dimensions:Up to 100m in free air868MHz (CE Approved,Licence Free)86 x 46 x 16mmDimensions in mmfront4686side16Order code: HASE 2RFRadio remote control wire-free card operated wall senderOrder code: WACC RFSCard operated wall senderIdeal for use in hotels, hospitals, restricted workareas etc. Sends on 1 unique channel.Complete with CR2477N battery.SpecificationSignal range:Carrier frequency:Finishes:Dimensions:Up to 50m in free air868MHz (CE Approved,Licence Free)Please call for details96 x 88 x 17mm, complete withdry line wall box, depth 35mmDimensions in mmfront9688side17Also available: Slave senders See page 63 for details.56


RADIO REMOTE CONTROLSRadio remote control wire-free wall sendersWire-free. No wall box needed.Complete with CR2430 battery(ies).Wall senders can be mounted using the pre-fixed adhesive strips to any fixed surface.SpecificationDimensions in mmSignal range:Up to 100m in free airfrontsideOrder code: WASE 1RF WHICarrier frequency:868MHz (CE Approved,Licence Free)9613WASE 1RF WHIDimensions:Sends on 1 unique channel.96 x 88 x 13mm88Dimensions in mmfrontsideWASE 2RF WHISends on 2 unique channels.9613Dimensions:96 x 88 x 13mm88Order code: WASE 2RF WHIWASE 4RF WHIDimensions:Sends on 4 unique channels.169 x 88 x 13mmDimensions in mmfrontside1691388Order code: WASE 4RF WHIRadio remote control wire-free external wall sender1 channel external wall mounted senderSends on 1 unique channel.No wall box needed.Complete with CR2430 battery.Dimensions in mmfront90side60Specification90Signal range:Up to 100m in free airCarrier frequency:868MHz (CE Approved,Licence Free)Order code: EXWASE 1RFDCWeatherproof:Dimensions:IP66 rating90 x 90 x 60mmHard wired, mains powered, external wall mountedsender available on request.Order code: EXWASE 1RFAC57


RADIO REMOTE CONTROLSRadio receiver switchesOrder code: WACE RFSOrder code:CEFL RFSOrder code:CEVO RFSWall or ceiling mounted switch: WACE RFSHard wired. Can be mounted on a 16mm box.Can be mounted out of sight.SpecificationLoading:Wiring diagram:Dimensions:Up to 6 amps (1500W) ofresistive load or up to 1 amp(250W) of transformer orfluorescent loadSee diagram 58 below86 x 86 x 22mmCeiling flush mounted switch: CEFL RFSDimensions in mmComplete with 2m cable for quick and easy installation. Loading and wiring as for WACE RFS.Dimensions:Hard wired switch: CEVO RFS72mm diameter x 68mm (requires 63mm diameter hole)Complete with 2m cable for quick and easy installation. Ideal for ceiling voids.Will fit through a 63mm diameter aperture. Loading and wiring as for WACE RFS.Dimensions:32 x 50 x 90mmplan8686side22Order code: CERF S6ARequires socket, order code:CESO or CESO SQ (see page 62)Plug-in switch: CERF S6APlugs into a Ceiling socket (shown on p.62).Can be mounted out of sight.SpecificationLoading:Wiring diagram:Dimensions:Up to 6 amps (1500W) of any type ofload, including fluorescent lights orup to 1 amp (250W) of fansSee diagram 58 below130 x 72 x 57mmDimensions in mmAlso available: Hard wired switch: CEVO RFS6AComplete with 2m cable for quick and easy installation. Loading and wiring as CERF S6A.Dimensions:130 x 72 x 57mmplan72130side57Order code: DIN RFSDIN rail receiver switch: DIN RFSFor fixing on to either 35 x 7.5mm top-hat DIN railor 32 x 15mm G-type DIN rail.SpecificationLoading:Wiring diagram:Dimensions:Up to 6 amps (1500W) of resistiveload or up to 1 amp (250W) oftransformer or fluorescent loadSee diagram 58 below35 x 75 x 100mmDIN rail receiver dimmer also available on request.Dimensions in mmplan75100side35Wiring diagram58. Remote control switchingL230 VACreceiver switchSLNwire-freesenderload58


RADIO REMOTE CONTROLSRadio receiver switchesPlug-in adaptor switch: PORF S8APlugs into a UK 3-pin mains socket and has itsown 3-pin socket for a mains powered plug-indevice. Ideal for table lamps or displays.Dimensions in mmfront60side48SpecificationOrder code:PORF S8ALoading:Wiring:Dimensions:Up to 8 amps (2000W) ofresistive load or up to 1 amp(250W) of transformer orfluorescent loadPlugs into 13 amp mains socket138 x 60 x 48mm138Exterior switch: EXRFSHard wired. Outdoor mounted. Weatherproof toIP65 rating.Dimensions in mmfrontsideSpecification9835Loading:Up to 6 amps (1500W) ofresistive load or up to 1 amp(250W) of transformer orfluorescent load64Wiring diagram: See diagram 59a belowDimensions:98 x 64 x 35mmOrder code:EXRFSOrder code:WACE RF2SDual momentary switch: WACE RF2SHard wired. Wall or ceiling mounted.Twin actuator switch. Enables blinds to beopened, closed or adjusted to any positionrequired. Can be mounted on a 16mm box.Can be mounted out of sight.WACE RF2S can also be used as a slave tocontrol up to two DANLERS grid time lag orsoft start dimmer switches. This can allow RFcontrol of higher wattage loads including toroidaltransformers.SpecificationLoading:Wiring diagram:Dimensions:Dimensions in mmUp to 6 amps (1500W) of resistive load or up to 1 amp (250W) oftransformer or fluorescent loadSee diagrams 59b and 59c below86 x 86 x 22mmplan8686side22Wiring diagrams59a. Remote control switchingreceiver switchLSL230 VAC59b. Blind/motor control switchL (high current)WACE RF2SL230 VACSL1LSL2NContactor59c. Soft start dimmer with remotecontrolL230 VACWACERF2SSLSLNwire-freesenderloadNwire-freesenderContactorNDownMotorUpMotorNwire-freesendersoft startdimmerloadV59


RADIO REMOTE CONTROLSRadio receiver dimmers (trailing edge)Order code: WACE RFD250WWall or ceiling mounted dimmer:WACE RFD250WHard wired. Can be mounted on a 16mm box.Can be mounted out of sight.SpecificationLoading:Dimming technology: Trailing edgeUp to 250W of resistive,mains halogen* or dimmableelectronic transformer loadsWiring diagram: See diagram 61a on page 61Dimensions:86 x 86 x 22mmDimensions in mmplan8686side22Order code:CEFL RFD250WAlso available: Ceiling flush mounted dimmer: CEFL RFD250WComplete with 2m cable for quick and easy installation.Loading and wiring as for WACE RFD250W.Dimensions:72mm diameter x 68mm (requires 63mm diameter hole)Order code:CEVO RFD250WAlso available: Hard wired dimmer: CEVO RFD250WComplete with 2m cable for quick and easy installation.Ideal for ceiling voids.Will fit through a 63mm diameter aperture.Loading and wiring as for WACE RFD250W.Dimensions:32 x 50 x 90mmPlug-in adaptor dimmer: PORF D250WPlugs into a UK 3-pin mains socket and has its own3-pin socket for a mains powered plug-in device.Ideal for table lamps or displays.SpecificationLoading:Dimming technology: Trailing edgeWiring:Dimensions:Up to 250W of resistive, mainshalogen* or dimmable electronictransformer loadsPlugs into 13 amp mains socket138 x 60 x 48mmDimensions in mmfront60138side48Order code:PORF D250WOrder code: EXRF D250WExterior dimmer: EXRF D250WHard wired. Outdoor mounted.Weatherproof to IP65 rating.SpecificationLoading:Dimming technology: Trailing edgeUp to 250W of resistive,mains halogen* or dimmableelectronic transformer loadsWiring diagram: See diagram 61a on page 61Dimensions:98 x 64 x 35mmDimensions in mmfront9864side35*Mains halogen lamps must have an integral thermal safety fuse.60


RADIO REMOTE CONTROLSRadio receiver dimmers (trailing edge)Plug-in dimmer: CERF D500WDimensions in mmPlugs into a Ceiling socket (shown on p.62).Can be mounted out of sight.planDimensions in mm72side57SpecificationOrder code: CERF D500WLoading:Dimming technology: Trailing edgeUp to 500W of resistive,mains halogen* or dimmableelectronic transformer loads130Wiring diagram:See diagram 61a belowDimensions:130 x 72 x 57mmBuild-in dimmer: CERF D500W GTIdeal for building into a luminaire or gear tray.Hard wired build-in dimmer.SpecificationLoading:Dimming technology: Trailing edgeWiring diagram:Up to 500W resistive, mainshalogen* or dimmable electronictransformer loadsSee diagram 61a belowDimensions in mm151plan151side3428Order code:CERF D500W GTDimensions:151 x 34 x 28mmBuild-in dimmer: CERF D10VDC MBIdeal for building into a luminaire or gear tray.For controlling dimmable ballasts with a 1-10VDCanalogue input.SpecificationDimensions in mm151plan34Order code:CERF D10VDC MBLoading:Up to 6 amps (1500W) ofresistive load or up to 4 amps(1000W) of fluorescent load.Total load of ballasts, lamps plusother loads not more than 2 amps.Can control up to 20mA, eg. 20ballasts at 1mA.Dimming technology: 1 to 10V with relay offside15128Wiring diagram:See diagram 61b belowDimensions:151 x 34 x 28mmWiring diagrams61a. Remote control dimming61b. CERF D10VDC MB controlling several1-10VDC dimmable ballasts*Mains halogen lamps must have an integralthermal safety fuse.LN230 VACwire-freesenderreceiver dimmerVloadLNCERF D10VDC MB230 VACwire-freesenderSLcontrol lines1ballast101ballast101ballast1061


RADIO REMOTE CONTROLSSlave radio sendersFor use with DANLERS plug-in switches, such as PIR occupancy switches or Photocellswitches. For controlling other remote circuits via Radio receiver switches or dimmers(shown on pages 58 to 61).The SLSE 1RFSO is hard wired.Requires mains power supply.Sends on 1 unique channel.For programming, requires Test plug (order code TEPL).SpecificationDimensions in mmplan87side41Signal range:Up to 100m in free air87Order code: SLSE 1RFSOWiring diagram:See diagram 63 belowDimensions:87 x 87 x 41mmWiring diagram63. Radio slavesender andradio receiverLDANLERSplug-inswitchSLSE 1RFSOL1Radio receiverload230 VAC230 VACNN1Also available on request:Outdoor 2 channel slave radio sender (Order code: EXSLSE 2RF).Customised functions and scene-settingBy special order DANLERS can supply packages of Senders and Receivers which arefactory pre-programmed to perform specified special switching and/or dimming functions.The table lists some of the special functions that are available, plus examples of howthese functions may be used.Even packages which perform several different functions can be supplied.Please note there is an additional charge to customise for special requirements and acharge for programming on site.Please call to discuss your particular requirements.Special switching functionTime delay ONTime delay OFFTime delay OFF with warningMomentary ONFlashingMotor controlExample applicationFor a special stage effectA courtesy light for leaving a buildingDemand for lighting for few minutes in astock cupboard, with flashing prompt tore-press the sender before the lights go outTo sound a doorbellTo give an alert signal (e.g. testing inprogress)To open and close blinds, screens or shuttersSpecial dimming functionGradual dimming or brighteningSelect a pre-set lamp brightnessGradual dim to pre-set levelSoft start switch onExample applicationTheatre house lights or presentation roomsTo set a mood for restaurant lightingTo give comfortable background lighting in aconferenceTo give a subtle switch on effect for ahotel room63


ACTIVE INFRA-RED REMOTE CONTROLSFor simple remote control set-ups with on/off switching, using Active infra-red hand heldsenders and wall or ceiling mounted receiver switches. The hand senders have a range ofapproximately 10 metres line of sight.Infra-red remote control switchingOrder code:CEFL AIROrder code:WACE AIRA mains supply interrupt for a few seconds canbe used to reset the switches to off.The CEFL AIR can be flush mounted through afalse or plasterboard ceiling. It has a 2m cablefor quick and easy installation.The WACE AIR can be wall mounted or ceilingsurface mounted on a 16mm (plaster depth) box.Multi-channel switchingIt is possible to have a multi-channelarrangement to control several different circuitsof lights or other loads.Each receiver would switch its own circuit. Eachreceiver can be set to receive on one of fourchannels (A, B, C or D).The hand senders work on different combinationsof channels (as indicated in the order codes).SpecificationLoading:Wiring diagram:Dimensions:Up to 6 amps (1500W) ofresistive, fluorescent ortransformer lighting loads,or up to 1 amp (250W) offans.See diagram 64 belowCEFL AIR:72mm diameter x 68mmWACE AIR:86 x 86 x 22mmDimensions in mm (CEFL AIR)65side2m cable6172Dimensions in mm (WACE AIR)front / plan86573plan72Requires 63mm or 64mm(2.5") diameter hole in a falseor plasterboard ceiling8624side22Hand sendersRange of approximately 10 metres line of sight.Hand senders send coded signals to switch theremote control switches on and off.Available as 1, 2 and 4 channel versions withcombinations of channels (A, B, C, D), as inorder codes.Each hand sender requires two AA batteries.Dimensions in mmfront61100side21Dimensions:100 x 61 x 21mmOrder codes:HASE AHASE BCHASE ABCDWiring diagram64. Remote control switchingLreceiver switch230 VACNwire-freesenderload64


ADDITIONAL PRODUCTSCeiling boxBox suitable for ceiling socket.Ideal for ceiling mounting.Has a 20mm entry spout.sideplanSpecificationDimensions:65mm diameter24.5 29 24.565 65Order code:CEBOCeiling pattress boxBox suitable for square ceiling products.Ideal for ceiling mounting.Has a 20mm knockout.plan87side28SpecificationDimensions:87mm x 87mm87internal depth 25mmOrder code:PABOTest plugTests a ceiling socket by linking the live andswitched line terminals.sideplanSpecificationDimensions:57 x 35.5 x 33mm2633575735.5Order code:TEPLLoad resistorRESLOAD can be used to try to eliminate lampinstability and flicker when dimming non-resistiveloads such as mains directly dimmable LEDlamps or dimmable transformers.Plan viewEnd view155835SpecificationOrder code:RESLOADDimensions:80 x 58 x 50mm.Can be passed through a63mm diameter cutout.803665


BESPOKE PRODUCTSSpecial versions of various DANLERS products can be supplied to Original Equipment Manufacturers or other customers. Pleasecall us to discuss your requirements. Here are some examples:Low voltage PIR occupancy switchesWe manufacture various 24V (a.c. or d.c.) versions of our PIR occupancy switches andphotocell switches, ideal for low voltage control systems. 12V versions can also besupplied, depending on the quantity required. Many of these items are often held in stock.Please see page 14 for some of the Ceiling flush mounted variants.To special order we can also supply PIR occupancy switches with volt-free outputs(including versions with gold contact relays) available for use with mains, 24V or 12Vsupplies.The circuit diagrams on page 67 show how these products can be used.Pre-wired controlsWe can manufacture various bespoke pre-wired controls for use with marshalling boxcontrol systems as well as different cable lengths on standard products.Low voltage high frequency dimmersWe can manufacture bespoke 1-10 volt PIR occupancy switches with daylight linkeddimming with 24V (a.c. or d.c.) supply.Bespoke time lag switchesTime lag switches with bespoke specifications can be supplied, depending on thequantity required.The special features which can be supplied are:• Different time lag ranges• Fixed time lags• Warning signal before load is switched off (e.g. lighting load flashing off and back onagain 1 minute before switch off)• Ability to manually switch off while part way through a time lag• Different coloured illuminated push buttons• Variants on the Heater boost switch (page 53) with different time lag options and/ordifferent printing on the front plate• Designed to operate from different supply voltages• With switched outputs or volt-free outputs.Adaptor box with plugWe can also supply our squareplated hard wired controlsmounted on a special adaptorbox with a plug, suitable forour Ceiling sockets (CESO andCESO SQ) and our Ceiling slaverelays (CESL and CE2SL).DANLERScontrol mountedon Adaptor boxwith plugManufacturing servicesDANLERS offer manufacturing services, including surface mount and through holeelectronic assembly, for other manufacturers.Please contact us todiscuss your requirementsor visit DANLERS ContractElectronics Manufacturingwebsite:www.danlerscem.co.uk66


BESPOKE PRODUCTSSwitched output67a. Standard products (230VAC supply)67b. 24 Volt (AC or DC) supply67c. 12 Volt (AC or DC) supplyLoptional manualwall switch foroverriding offDANLERS control+24Voptional manualwall switch foroverriding offDANLERS control+12Voptional manualwall switch foroverriding offDANLERS control230 VAC24V (AC or DC)12V (AC or DC)loadloadloadN0V0VVolt-free output (including gold relay contacts for integrating into building management systems)67d. 230VAC supply67e. 24 Volt (AC or DC) supply67f. 12 Volt (AC or DC) supplyLoptional manualwall switch foroverriding offDANLERS controlvolt-freecontacts+24Voptional manualwall switch foroverriding offDANLERS controlvolt-freecontacts+12Voptional manualwall switch foroverriding offDANLERS controlvolt-freecontacts230 VAC24V (AC or DC)12V (AC or DC)N0V0VOpen collectorOpen collector output can be implemented with DANLERS Logic Gold, Volt Free product variants.Relay contact material optionsSTANDARD:GOLD:LOGIC GOLD:High voltage, high currentHigh voltage, low currentLow voltage, low current.67


O.E.M. PRODUCTSBuild-in PIR occupancy switchesDANLERS manufacture bespoke passive infra-red occupancy switches for manufacturersto build into luminaires.These are ideal for energy saving as they ensure that unnecessary lighting is switched offautomatically.Please contact us to discuss your requirements.Each product contains a passive infra-red quad person detector, adjustable time lag (beforeswitch off), adjustable photocell and a relay suitable for switching lighting loads.The products require a neutral connection.Please also refer to pages 22 - 23 for PIR occupancy switch Eurodata grid modules.Please also refer to pages 19, 24 - 25 for some of DANLERS solutions for warehouses andstorage aisles.Typical specificationPerson detector:Time lag range:Photocell range:Loading:Typical mounting heights:Passive infra-red quad detectorAdjustable time lag settingsAdjustable photocell settingsUp to 6 amps (1500W) of resistive, transformer or fluorescentlighting loads, 2 amps (500W) of low energy lighting loads(LED lamps and compact fluorescent) or up to 1 amp (250W)of fans or most metal halide lamps5m, 10m, 12m, 20mA mounting bezel (order code GREUW BEZEL)is available for mounting Eurodata grid modules.Example detection patternsThe examples below could be used in warehouses, storage facilities and other applicationsMountingheightup to5m120°Mountingheightup to12mMountingheightup to20mUp to 7m6°Mountingheightup to10mUp to20mup to 3mUp to 12m2mUp to 15m2m68


O.E.M. PRODUCTSSoft start dimmer modulesDescriptionSoft start dimmer moduleSame functions and features as theplated Soft start dimmers, shown onpage 46. For wiring diagrams see page45 (diagrams 45a-45c).Flush soft start dimmer moduleSame functions and features as theplated Soft start dimmers, shown onpage 46. For wiring diagrams see page45 (diagrams 45a-45c).Quiet dimmer moduleSame functions and features as thequiet grid dimmer modules, shown onpage 45. For wiring diagrams see page45 (diagrams 45a-45c).Order codeMin. and Max. wattage:resistive, mains halogenor dimmable electronictransformer loadsMin. and Max. wattage:dimmable wire-woundor toroidal transformerinductive loadsMax. no. oftransformersDimensions(mm)DSS 250W 40 - 250W 40 – 160W 4 66x28x29DSS 400W 60 – 400W 60 – 250W 6 66x28x29DSS FL 250W 40 - 250W 40 – 160W 4 65x26x25DSS FL 400W 60 – 400W 60 – 250W 6 45x24x38DQD FL 400W 40 – 400W Not suitable 6 45x24x38Slave switch moduleSS SLSuitable for use with DANLERS Soft start dimmers66x28x29and Quiet dimmers and modules, and DANLERSFlush slave switch module SS FL SLTime lag switches.45x24x38High frequency dimmer modulesDescription Order code Load / Number of ballasts Dimensions (mm)Push on, push off, with rotarydimming controlFor dimmable high frequency ballaststaking a 1-10VDC input.Based on 1-10VDC High frequencyplated dimmers shown on page 50.For wiring diagrams see page 50(diagrams 50a-50b).DPD 10VDC SBDPD 10VDC MB1 or 2 ballasts. Total load of ballasts, lamps plusother load not more than 6 amps.Total load of ballasts, lamps plus other load notmore than 6 amps.Can control up to 20mA, eg. 20 ballasts at 1mA.Multiple ballasts (varies according to make andmodel of ballast).64x25x21+ terminal block64x26x28Flush high frequency dimmermoduleFor dimmable high frequency ballaststaking a 1-10VDC input.Based on 1-10VDC High frequencygrid dimmers shown on page 51.For wiring diagrams see page 51(diagram 51).DSS FL 10VDCTotal load of ballasts, lamps plus other load notmore than 6 amps.Can control up to 20mA, eg. 20 ballasts at 1mA.(Varies according to make and model of ballast)45x24x38Dimensions in mmDSS 250W, DSS 400W, SS SLfrontsideDSS FL 400W, DQD FL 400W,SS FL SL, DSS FL 10VDCDPD 10VDC SBfrontsideDPD 10VDC MBfrontside2824front24side382 way terminalblock onflying leads2521262466456464SpindleØ = 6mm29SpindleØ = 6mmSpindleØ = 6mm28DSS DPD FL 10VDC 250WMBfront26side256569


O.E.M. PRODUCTSDimmer modules and time lag modules are available for other Original Equipment Manufacturers to mount on their own wall plates.Rotary and push dimmer modulesOur range includes dimmer modules with rotary or push mechanical switches, and to suit resistive loads. Also suitable fordimmable electronic transformer loads or inductive transformer loads. No need to derate for mains halogen lamps (follow theresistive wattages in the tables below).Rotary switch dimmer modules for resistive loadsOrder code Min. and Max. wattage - resistive loads Min. and Max. wattage - transformer loads Dimensions (mm)DRD 250W 40 – 250W Not suitable 64x25x21DRD 400W 60 – 400W Not suitable 64x25x21Push switch dimmer modules for resistive loadsFor wiring diagrams see page 47 (diagrams 47a -47h).Order code Min. and Max. wattage - resistive loads Min. and Max. wattage - transformer loads Dimensions (mm)DPD 250W 40 – 250W Not suitable 64x25x21DPD 400W 60 – 400W Not suitable 64x25x21DPD 630W 60 – 630W Not suitable 64x44x42DPD 1000W 100 – 1000W Not suitable 104x50x24Push switch dimmer modules for dimmable wire-wound transformer low voltage loadsFor wiring diagrams see page 47 (diagrams 47a -47h).Order codeMin. and Max. wattage -resistive loadsMin. and Max. wattage -transformer loadsMax. no. oftransformersDimensions (mm)DPD 250WI 60 – 400W 60 – 250W 6 64x25x21DPD 400WI 60 – 630W 60 – 400W 8 64x44x42DPD 630WI 60 – 1000W 60 – 630W 12 104x50x24Push switch dimmer modules for dimmable electronic transformer low voltage loadsFor wiring diagrams see page 47 (diagrams 47a -47h).Order codeMin. and Max. wattage -resistive loadsMin. and Max. wattage -transformer loadsMax. no. oftransformersDimensions (mm)DPD 250WIET 40 – 250W 40 – 250W 4 64x25x21DPD 400WIET 60 – 400W 60 – 400W 6 64x25x21DPD 630WIET 60 – 630W 60 – 630W 8 64x44x42DPD 1000WIET 60 – 1000W 60 – 1000W 12 104x50x2470


O.E.M. PRODUCTSRotary and push dimmer modulesPush switch module, 1 or 2 way switching. Any type of load. (No dimming.)For wiring diagrams see page 47 (diagrams 47a -47h).Order code Maximum resistive load Maximum transformer load Dimensions (mm)DPS 1500W 6 amps 6 amps 64x25x21Rotary intermediate switch module. Any type of load. (No dimming.)For wiring diagrams see pages 47 (diagrams 47e -47h).Order code Maximum resistive load Maximum transformer load Dimensions (mm)DRS 1000WINT 4 amps 4 amps 64x25x29Time lag switch modulesThese modules have adjustable time lags.They require 3 wire connections: live, neutral and switched line.Based on 3-wire plated time lag switches shown on page 36 (TLSW A20 and TLSW A120).For wiring diagrams see page 37 (diagrams 37a - 37b, 37d - 37e). (Can be wired in parallel,however cannot be operated by slave switches.)Loading:Up to 6 amps (1500W) of resistive, fluorescentor inductive lighting loads, or up to 1 amp (250W) of fans.Order code Time lag range Dimensions (mm)TL A20 2 – 20 minutes 64x25x31TL A120 12 – 120 minutes 64x25x31Dimensions in mmProducts opposite and abovemeasuring 64x25x21mm(various push and rotary dimmermodules and push switch module)front25side21Products opposite measuring64x44x42mm(various push dimmer modules)front44side42Products opposite measuring104x50x24mm(various push dimmer modules)front50side246464104SpindleØ = 6mmSpindleØ = 6mmSpindleØ = 6mmDRS 1000WINT64x25x29mm(rotary intermediate switch module)TL A20, TL A1202529frontsidefrontside25216464SpindleØ = 6mmSpindleØ = 6mm3171


DANLERS LimitedDANLERS Business CentreVincients Road, CHIPPENHAMWiltshire, SN14 6NQ United KingdomTel:+44 (0)1249 443377Fax:+44 (0)1249 443388E-mail: sales@danlers.co.ukwww.danlers.co.ukISO 9001: 2008Registration No. 879ISO 14001: 2004Registration No. 879Company Registered Number 2570169 VAT Registration Number 543 5491 38January 2012