10.07.2015 Views

TECTUM fLaT roof sysTEM Easy aCCEss To frEE ... - Soltecture GmbH

TECTUM fLaT roof sysTEM Easy aCCEss To frEE ... - Soltecture GmbH

TECTUM fLaT roof sysTEM Easy aCCEss To frEE ... - Soltecture GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>TECTUM</strong>FLAT ROOF SYSTEM<strong>TECTUM</strong> – <strong>Easy</strong> accessto free energyIntelligent System – Well-engineered and lightweight<strong>Soltecture</strong> transforms plain, unused flat <strong>roof</strong>s into solar energy powerplants, even those covered with <strong>roof</strong>ing membranes*, bituminous sheeting,or gravel. Where other system solutions prove too heavy, <strong>Soltecture</strong>’s flat<strong>roof</strong> system, weighing


<strong>TECTUM</strong>FLAT ROOF SYSTEMFlat <strong>roof</strong> system <strong>TECTUM</strong> 90 <strong>TECTUM</strong> 95 <strong>TECTUM</strong> 100Electrical characteristics at 1000 W/m 2 ; 25 °C; AM1.5Rated power P max 90.0 W 95.0 W 100 W<strong>To</strong>lerance (P max) +5/­0 W +5/­0 W +5/­0 WModule efficiency 11.1% 11.7% 12.3%Rated voltage 1) U mpp 56.2 V 57.2 V 58.2 VRated current 1) I mpp 1.64 A 1.67 A 1.70 AOpen circuit voltage 1) U oc 72.2 V 73.1 V 74.0 VShort circuit current 1) I sc 1.80 A 1.82 A 1.83 AMaximum system voltageIEC 61730 1000 V 1000 V 1000 VUL 1703 600 V 600 V 600 VReverse current rating 3 A 3 A 3 AMax. no. of modules connected in series per string+10% tol., 1000 V, -10 °C [IEC] (600 V, 14 °F [UL])11 (UL: 6) 11 (UL: 6) 11 (UL: 6)Individual strings connected to a blockingMaximum no. of modules in parallel 2)diode in (+) and 3 A fuse in (­).Electrical characteristics at 800 W/m 2 ; NOCT; AM1.5Power 1) P max 65.2 W 67.8 W 70.5 WVoltage 1) U mpp 49.6 V 50.8 V 51.9 VCurrent 1) I mpp 1.31 A 1.34 A 1.36 AOpen circuit voltage 1) U oc 64.7 V 65.9 V 67.1 VShort circuit current 1) I sc 1.44 A 1.45 A 1.47 AElectrical characteristics at 200 W/m 2 ; 25 °C; AM1.5Maximum absolute reduction of efficiency 0.8% 0.8% 0.8%Thermal behaviorWorking temperature (NOCT) 49 °C (120 °F) 49 °C (120 °F) 49 °C (120 °F)Power temperature coefficient T C (P max) ­0.45%/K ­0.43%/K ­0.41%/KVoltage temperature coefficient T C (U oc) ­0.35%/K ­0.33%/K ­0.31%/KCurrent temperature coefficient T C (I sc) +0.01%/K +0.01%/K +0.01%/KOperating conditionsTemperature range­40 °C to +85 °C (­40 °F to 185 °F)Maximum mechanical IEC 61730 2400 Pa; 245 kg/m 2load 3) UL 1703 1600 Pa; 33 lbs/ft 2Maximum torsion 1.2°IP code (to IEC 60529)IP65Protection class (to IEC 61140)IIApplication class (to IEC 61730)AFire rating (to IEC 61730)Cnotes1) <strong>To</strong>lerance of the electrical parameters ± 10%2) Limited: See explanation in the Electrical Configuration sectionin the installation instructions for <strong>Soltecture</strong> PV modules.3) See <strong>Soltecture</strong> <strong>GmbH</strong>’s independent manufacturer warrantyfor Linion PV modules (last revised October 2011).The modules are not suitable for mobile or maritime applications. Please note that if the LinionPV modules are stored in dark spaces for long periods, they must then be exposed to sufficient solarradiation to attain their rated output. Please refer to our user information at www.soltecture.com/download-centre. as we continually optimize our solar modules, related data pertinent to thesechanges will be cited in the technical data sheet. All information applies exclusively to modulesproduced during the most recent product revision. The modules are certified for use in the followingcountries: EU countries, Switzerland, Norway, Turkey, Liechtenstein, Israel, Lebanon, Croatia,Bosnia and Herzegovina, Serbia. (09/2010)for technical questions, please contact us at: service@soltecture.deDimensions of the flat <strong>roof</strong> elementHeight / Width / Length222 / 1163 / 1260 mm (8.74 / 45.8 / 49.6 in)Weight15.5 kg (34.2 lbs)System’s mass per unit area12.3 kg/m² (2.52 lbs/ft²)Additional dataMaximum string fuse3 A (e.g. Socomec 60PV0003)Included bypass diode1 x Diotec BY550­1000Connection cable 2 x 1000 mm (39.4 in) / 4 mm² (AWG 11)Plug connector Y­SOL 4Cell typeCIGSe thin­filmFront glass3 mm (0.12 in) tempered safety glassRear glass3 mm (0.12 in) float glassEncapsulationEVACertificates and warrantiesTÜV certificates:IEC 61646, IEC 61730Manufactured in the EUCE-marking• Qualified, IEC EN 61646• Safety tested, IEC 61730• Periodic InspectionFurther information atwww.tuv.com ID: 000033202 andwww.soltecture.com/download-centreIndependent product warranty 10 years (for Linion L modules) 3)Independent output warranty 25 years (for Linion L modules) 3)2.0Example characteristic curves at various temperatures – Linion 90 module typeZ1000 (39.4˝)Current [A]1.51.00 °C(35 °F)25 °C(77 °F)50 °C(122 °F)0.575 °C(167 °F)00 10 20 30 40 50 60 70 80Voltage [V]Temp[°C (°F)]75 (167)50 (122)25 (77)0 (35)Umpp[V]43.049.756.262.7Impp[A]1.621.631.641.65Pmax[Wp]69.881.092.2103.517°10°Current [A]2.01.51.00.5Example characteristic curves at various irradiances – Linion 90 module type1000 W/m 2800 W/m 2600 W/m 2400 W/m 2200 W/m 2E[W/m 2 ]1000800600400200Umpp[V]56.255.655.054.453.8Impp[A]1.641.310.990.660.33Pmax[Wp]92.373.154.235.717.7222 (8.74˝)230 (9.06˝)50°9,510°Z (1:4)70°118(4.65˝)10°112(4.41˝)00 10 20 30 40 50 60 70 80Voltage [V]1163 (45.8˝)6(0.24˝)<strong>TECTUM</strong>­EN­REV 2.3<strong>Soltecture</strong> <strong>GmbH</strong>Groß­Berliner Damm 149D­12487 BerlinTel.: +49 (0)30 46 77 77 – 0Fax: +49 (0)30 46 77 77 – 400info@soltecture.dewww.soltecture.comYour <strong>Soltecture</strong> Partner:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!