10.07.2015 Views

Testo 350 XL Brochure - CleanAir - Express Equipment Sales

Testo 350 XL Brochure - CleanAir - Express Equipment Sales

Testo 350 XL Brochure - CleanAir - Express Equipment Sales

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The Analyzer Box - “S” or “<strong>XL</strong>” modelThe analyzer box is the “heart” of the measuring system and isavailable in two different versions:The basic <strong>350</strong>-S modelThe testo <strong>350</strong>-S comes standard with an O 2 cell and one other moduleof your choice. However, up to five additional modules (NO 2, SO 2, NO,NO LOW, C O, C O LOW, H2S, C XHY or C O 2) can also be retrofitted for amaximum of six cells. Temperature and differential pressure arestandard while efficiency and excess air are calculated. Upgrades tothe “S” model include a sample conditioning system, dilution systemand/or fresh air valve for long-term monitoring.The advanced <strong>350</strong>-<strong>XL</strong> modelAll of the “S” model upgrades are standard in the “<strong>XL</strong>” version.• Test up to six gases simultaneously or swap them for additionalparameters with convenient plug and play sensors(CXHY, NO LOW, C O LOW, SO 2, H2S, C O 2)• Advanced sample conditioning utilizes an integratedPeltier chiller for moisture drop-out, a peristaltic hosepump for controlled water removal, and quick-changeparticulate filters• Proven sample gas path with Teflon ® lined hoses• Continuous temperature compensation forassured accuracy• Innovative dilution systems for the widest testing rangesand greatest sensor protection. C O to 400,000 ppm!NO, NO 2, SO 2, H2S to 5 times the sensor range• User defined programs with onboard memory to250,000 values• Integrated pressure measurement for draft, ∆P,velocity and mass emission• Rechargeable battery with outboard DC connectionand AC operation• Flow rate and sensor temperature monitoring for USEPA CTM-030, -034 and ASTM D6522 requirements• Comprehensive calculations including O 2 corrections forNOX, C O, and SO 2, mass measurement with pitot andstack dimension input• Simple on-site sensor calibration capability includingdiagnostics and sensor output (0 – 100%)Compare Analyzer Box Models S and <strong>XL</strong>testo <strong>350</strong> S testo <strong>350</strong> <strong>XL</strong>Maximum no. of sensors 6 6O2 0 – 25 Vol. ■ ■CO (H2) 0 – 10,000 ppm O ■COLOW (H2) 0 – 500 ppm O ONO 0 – 3,000 ppm (0.1 ppm resolution) O ■NOLOW 0 – 300 ppm (0.1 ppm resolution) O ONO2 0 – 500 ppm (0.1 ppm resolution) O ■SO2 0 – 5,000 ppm O OHC 0 – 4 Vol. % (0.001 % resolution) O OH2S 0 – 300 ppm (0.1 ppm resolution) O OCO2 (NDIR) 0 – 50 Vol. % O OBuilt-in gas preparation unit (is recommended forcompliance testing, high humidity levels and long-termmeasurements >2 hrs measuring time)O ■Automatic fresh air rinse with valve (incl. measurementrange extension with dilution factor 5 for all sensors) O ■Measurement range extension for CO measuringmodule (with selectable dilution factors) O OCO measuring module switch-offvia adjustable switch-off threshold■ ■Trigger input – stops and starts measurement externally O ODifferential pressure measurement(-16” to +16” H2O/-80” to +80” H2O)■ ■Built-in rechargeable battery ■ ■2 temperature probe sockets (Type K NiCr-Ni) ■ ■Data logger (250,000 readings) ■ ■testo data bus connection ■ ■Bluetooth ® 2.0 O O = StandardO = Upgrade Option5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!