Model SH-100Model SH-200Warning:Maximun space between parts = 3 mmElectrical features:Power supply:10-36 V dc, there is no need to set the voltageConsumption for 12 V dc 2A startup and 0,5 A operating current.Coil:Tropicalized.Autoprotection:If the closing manoeuvre is not executed correctly because there is a defect inalignment or there is an object preventing closure, the system tries to close severaltimes. If after five attempts the shearlock cannot be closed, it remains in theopen position and triggers an alarm. This prevents the product from overheating,which causes the deterioration of the product.Power supply connectionLEDT2 Release-delay adjustmentFOR PANIC DEVICEST1 Locking-delay adjustmentAuxiliary relay:Inversion circuit. Maximum current: 1 A at 24 V dc.When activated, the door is locked.When deactivated, the door is released.Time delays:When locking/ aligning: 4 sec. ( adjustable from 0 to 25 sec )When releasing/ in an emergency: 15 sec ( adjustable from 0 to 25 sec )The adjustments can be independent from each other. Values shown are factorydefault settings.Additional features:Locking prevention: this connection keeps the door released, even though thepower is connected.Opening delay: either through an instantaneous connection or a button withtimed opening.Alarms:Intermittent alarm:The electromagnet and door plate are not aligned.Attempted forced entry.Coil malfunction.Position sensors not aligned.Alarm indications are cancelled after 15 sec. or disconnecting the powersupply.Continuous alarm:Indicates the countdown to door release.Deactivates through the locking-prevention system or by disconnecting thepower supply.3 color LED indicator:Green: door released.Red: door closed.Amber: malfunction or transitory state.1 A at 24 VMagnetic alignmentsensorsPower supply (10 to 36 VDC)Emergency release delayAuxiliary ( - )Alarm ( - )RelayTransistor within the shearlock’s own electronic circuitImmediate release and reset auxiliary ( + )External alarm circuit:4 + Common with the shearlock8 - Auxiliary through the transistor in the shearlock circuitMaximum current: 350mAPulsador apertura instantánea y reset4 + Common with the shearlock3 Active29

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!