10.07.2015 Views

Product Brochure - Videx Security

Product Brochure - Videx Security

Product Brochure - Videx Security

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

general catalogue09/10


Openers & Closers was founded in Barcelona in 1989, with the aim ofmanufacturing quality door locks and ensuring an efficient customer service.After 20 years of experience, O&C is one of the leading European manufacturersof electric strikes and electromagnetic locks, exporting approximately 90%of production in over 40 different countries.Such achievement is probably the result of the company’s policy of constantlyimproving product quality while maintaining an affordable price, in combinationwith the staff engagement to educate, update and advise clients on aregular basis.O&C currently owns over 30 patents for technical and production innovations,entirely designed and manufactured in Spain. All our products have been testedby APPLUS+ Norcontrol and LGAI Technological Center.Nevertheless, higher quality means lower energy consumption and less wastegeneration thanks to longer product life. As a matter of fact, our products areguaranteed from 3 to 5 years. Our commitment to the environment is also witnessedby our respect of the RoHS.OPENERS & CLOSERS: INNOVATION, QUALITY & SERVICE.


electric strikesnewnewasymmetrical electric strikessymmetrical electric strikessecurity electric strikessecurity electric strikes with electronic coilelectric strikes for panic devices16,5 mm symmetrical mini electric strikesIP54 waterproof electric strikessecurity electric strikes for armoured doorssteel electric strikes for RF-120 doorssymmetrical steel electric strikes


asymmetrical electric strikesReferences and featuresFixedlatchAdjustablelatchPreloadVoltageReferencesDIN rightadd faceplateReferencesDIN leftadd faceplateFail-secureThe electric strike is locked when unenergized.Fail-secure with mechanical unlatchingIt works just like the Fail-secure model but with mechanical release function.Hold-openThe electric strike has a device that allows its opening with a single electric impulse. Itremains in open position until the closing of the door.Hold-open with mechanical unlatchingIt works just like the Hold-open model but with mechanical release function.Internal Hold-openThe electric strike has an internal device that allows its opening with a single electricimpulse. It remains in open position until the closing of the door.Internal Hold-open with mechanical unlatchingIt works just like the Internal Hold-open but with mechanical release function.8-14 V ac/dc5-12 V ac/dc12 V dc24 V dc8-14 V ac/dc5-12 V ac/dc12 V dc24 V dc8-14 V ac/dc5-12 V ac/dc12 V dc24 V dc8-14 V ac/dc5-12 V ac/dc12 V dc24 V dc8-14 V ac/dc5-12 V ac/dc8-14 V ac/dc5-12 V ac/dc8-14 V ac/dc5-12 V ac/dc8-14 V ac/dc5-12 V ac/dc9-14 V ac/dc6-12 V ac/dc9-14 V ac/dc6-12 V ac/dc9-14 V ac/dc6-12 V ac/dc9-14 V ac/dc6-12 V ac/dc10.0.00.B10.0.00.J10.0.00.E10.0.00.F10.1.00.B10.1.00.J10.1.00.E10.1.00.F11.0.00.B11.0.00.J11.0.00.E11.0.00.F11.1.00.B11.1.00.J11.1.00.E11.1.00.F12.0.00.B12.0.00.J12.1.00.B12.1.00.J13.0.00.B13.0.00.J13.1.00.B13.1.00.J12A.0.00.B12A.0.00.J12A.1.00.B12A.1.00.J13A.0.00.B13A.0.00.J13A.1.00.B13A.1.00.J20.0.00.B20.0.00.J20.0.00.E20.0.00.F20.1.00.B20.1.00.J20.1.00.E20.1.00.F21.0.00.B21.0.00.J21.0.00.E21.0.00.F21.1.00.B21.1.00.J21.1.00.E21.1.00.F22.0.00.B22.0.00.J22.1.00.B22.1.00.J23.0.00.B23.0.00.J23.1.00.B23.1.00.J22A.0.00.B22A.0.00.J22A.1.00.B22A.1.00.J23A.0.00.B23A.0.00.J23A.1.00.B23A.1.00.JFixed latchDimensions28Adjustable latchsymmetrical reversibilitywith DIN Right and LeftOperationHold-openasymmetrical reversibilitywith DIN LeftInternalHold-open33,5 46,821909,752,311Fail-secure Hold-open Internal Hold-openwith mechanical with mechanical with mechanicalunlatchingunlatchingunlatchingopened closed opened closedCoil featuresWarning:B8/14 V ac/dc(12 Ω 0,7 A a 12 Vac)J5/12 V ac/dc(8 Ω 0,6 A a 9 Vac)E12 Vdc 100%(60 Ω 0,20 A)F24 Vdc 100%(220 Ω 0,12 A)When installing door releases with DC connections,the electric strike latch should notexert any pressure on the door-release latch.Incorrect installation could causedoor-release failure.105655377Temperature test:Measured on coil surface, tolerance ±10%Technical features°CMinutes 5(a 12 Vac)Electric strikes with «ac» coils work properly even with a pressureup to 16Kg300.000 guaranteed openings°CMinutes 5(a 9 Vac)Withstands impacts up to 300 KgSteel screwsLow power consumption°CHours 5°CHours 5Other coils and voltages on demandCorrosion resistant according to UNI ISO 9227 StandardsComplies with electromagnetic compatibility standard 2004/108/CE(EN55014).2


236,52faceplatesfor asymmetrical electric strikes84GREY106,984CHROME255214584BRASSReversible25R 10R 104417216 1752BROWNBROWNReversible2ReversibleR 10R 10R 10R 10R 10R 10R 10R 10797935250250250355244445210210225025048,544121244525248,5R 10R 10323221212RightDINLeft322508 BROWN 0925RightDINLeftR 10R 10R 1012 BROWN 13R 101212RightDINLeft32DIN10 BROWN 11 Right Left14 BROWN 15252532R 10R 10R 10R 10Door HandednessDIN definition:The door is viewed from the side onwhich the hinges are visible.4DIN Left DIN Right DIN Left DIN Right


symmetrical electric strikesReferences and featuresReversibleAdjustablelatchPreloadElectronicprotectionVoltageReferenceslatch (1)add faceplateFail-secureThe electric strike is locked when unenergized.8-14 V ac/dc5-12 V ac/dc30.1.00.B30.1.00.J12 V dc30.1.00.E24 V dc30.1.00.FFail-Secure with mechanical unlatchingIt works just like the Fail-secure model but with mechanical release function.8-14 V ac/dc5-12 V ac/dc31.1.00.B31.1.00.J12 V dc31.1.00.E24 V dc31.1.00.FFail-safeThe electric strike is locked when energized.12 V dc24 V dc34.1.00.E34.1.00.FHold-openThe electric strike has a device that allows its opening with a single electric impulse.It remains in open position until the closing of the door.8-14 V ac/dc5-12 V ac/dc32.1.00.B32.1.00.JHold-open with mechanical unlatchingIt works just like the Hold-open model but with mechanical release function.8-14 V ac/dc5-12 V ac/dc33.1.00.B33.1.00.JInternal Hold-openThe electric strike has an internal device that allows its opening with a single electricimpulse. It remains in open position until the closing of the door.9-14 V ac/dc6-12 V ac/dc32A.1.00.B32A.1.00.JInternal Hold-open with mechanical unlatchingIt works just like the Internal Hold-open but with mechanical release function.9-14 V ac/dc6-12 V ac/dc33A.1.00.B33A.1.00.JOperationFail-secure Fail-secure Hold-openwith mechanicalunlatchingInternalhold-openHold-open Internal Hold-open Internal Hold-open Fail-safewith mechanicalwith mechanicalunlatchingunlatchingDimensions212912521110OpenedCoil featuresClosed1269Warning:B8/14 V ac/dc(14 Ω 0,7 A a 12 Vac)J5/12 V ac/dc(8 Ω 0,6 A a 9 Vac)E12 Vdc 100%(50 Ω 0,25 A)F24 Vdc 100%(185 Ω 0,12 A)When installing door releases with DC connections,the electric strike latch should notexert any pressure on the door-release latch.Incorrect installation could causedoor-release failure.105655377Temperature test:Measured on coil surface, tolerance ±10%°C°C°C°CTechnical featuresMinutes 5(a 12 Vac)Minutes 5(a 9 Vac)Hours 5 Hours 5Other coils and voltages on demandElectric strikes with «ac» coils work properly even with a pressureup to 16Kg.300.000 guaranteed openingsWithstands impacts up to 280 Kg.Steel screwsLow power consumptionCorrosion resistant according to UNI ISO 9227 StandardsComplies with electromagnetic compatibility standard 2004/108/CE(EN55014).5


2faceplatesfor security electric strikes25325344 65,549,55215961INOX 3mm644414270 44521225043INOX 3mmReversible253Reversible25344 65,55220066INOX 3mm9644521328067INOX 3mmReversibleReversibleR 10R 1017248,55216 1744BROWNBROWN3225R 10R 10ReversibleReversible2523232225R 10R 10R 10R 104425048,5127070139,754425048,561,7561,7512139,75525290,51407042R 10R 10R 10R 10RightDINLeftDIN44 BROWN 47 Right Left45 BROWN 4810


16,5 mm symmetrical mini electric strikescompact and high-strengthnewReferences and featuresRadialturninglatchReversibleAdjustablelatchPreloadElectronicprotectionVoltageReferenceslatch (1)add faceplateFail-secureThe electric strike is locked when unenergized.9-16 V ac/dc6-12 V ac/dc50.1.00.B50.1.00.J12 V dc50.1.00.E24 V dc50.1.00.FFail-secure with mechanical unlatchingIt works just like the Fail-secure model but with mechanical release function.9-16 V ac/dc6-12 V ac/dc51.1.00.B51.1.00.J12 V dc51.1.00.E24 V dc51.1.00.FFail-secure with microswitchIt works just like the Fail-secure model plus an electrical switching device that detectsthe status of the door.9-16 V ac/dc12 V dc24 V dc56.1.00.B56.1.00.E56.1.00.FFail-safeThe electric strike remains in closed position, while the coil is selected. When theelectric current is stopped, the electric strike stays in open position.12 V dc24 V dc54.1.00.E54.1.00.FFail-safe with microswitchLike the Fail-safe model plus an electrical switching device that detects the status of the door.12 V dc58.1.00.E24 V dc58.1.00.FHold-openThe electric strike has a device that allows its opening with a single electrical impulse. It remainsin open position until the closing of the door.9-16 V ac/dc6-12 V ac/dc52.1.00.B52.1.00.JHold-open with mechanical unlatchingIt works just like the Hold-open model but with mechanical release function.9-16 V ac/dc6-12 V ac/dc53.1.00.B53.1.00.JFail-secureFail-securewith mechanicalunlatchingFail-securewith microswitchHold-open Hold-open Fail-safewith mechanicalunlatchingDimensionsFail-safewith microswitch46,665,572,559,8139,89,8139,85,946,616,55,916Coil featuresWarning:When installing door releases with DC connections,the electric strike latch should notexert any pressure on the door-release latch.Incorrect installation could causedoor-release failure.Temperature test:Measured on coil surface, tolerance ±10%776046°CB 9/16 V ac/dcJ 6/12 V ac/dcE 12 Vdc 100%F 24 Vdc 100%(20 Ω 0,480 A a 12V ac) (8,5 Ω 0,820 A a 9V ac) (42 Ω 0,275 A) (192 Ω 0,120 A)16 VacMinutes 512 Vac9 Vac855839°CMinutes 512 Vac9 Vac6 Vac68°C28,1Hours 562°CHours 5Technical featuresElectric strikes with «ac» coils work properly even with a pressureup to 16Kg.300.000 guaranteed openingsReinforced anchor leversWithstands impacts up to 400 Kg.Steel screwsLow power consumptionOther coils and voltages on demandCorrosion resistant according to UNI ISO 9227 StandardsComplies with electromagnetic compatibility standard 2004/108/CE(EN55014).13


624,333,2227,544,548,3243,933,266,544,548,365,322INOX 3mm130,223INOX 3mm2,124RightDINLeftR 10212,166,524INOX 3mm25INOX 3mm32,5RightDINLeft18,824227,512,166,526INOX 3mm324,3Reversible14


IP54 waterproof electric strikesReferences and featuresFixedlatchPreloadElectronicprotectionVoltageReferencesDIN rightadd faceplateReferencesDIN leftadd faceplateFail-secureThe electric strike is locked when unenergized.8-14 V ac/dc12 V dc7R0.4.00.L7R0.4.00.M7L0.4.00.L7L0.4.00.M24 V dc7R0.4.00.N7L0.4.00.NFail-secure with 1 microswitchIt works just like the Fail-secure model plus an electrical switching device that detects the status of the door.8-14 V ac/dc12 V dc7R6.4.00.L7R6.4.00.M7L6.4.00.L7L6.4.00.M24 V dc7R6.4.00.N7L6.4.00.NFail-safeThe electric strike remains in closed position, while the coil is selected. When the electrical current isstopped, the strike stays in open position.Fail-safe with 1 microswitchIt works just like the Fail-safe model plus an electrical switching device that detects the status of the door.12 V dc24 V dc12 V dc24 V dc7R4.4.00.M7R4.4.00.N7R8.4.00.M7R8.4.00.N7L4.4.00.M7L4.4.00.N7L8.4.00.M7L8.4.00.NInternal Hold-openThe electric strike has an internal device that allows its opening with a single electrical impulse.It remains in open position until the closing of the door.9-14 V ac/dc7R2A.4.00.L7L2A.4.00.LFail-secure Fail-safe InternalHold-open1 microswitchFail-secure Fail-safeSchematic electricdiagram with microswitchDimensionsPower supply3621,2lightlightD I D I D I D I D IPushbuttonCOILNOCOMNCPushbuttonCOILNCCOMNO93,24,3®®®98,9<strong>Security</strong> coil support100% waterproof boxMagnet + 100% waterproof REEDCoil featuresWarning:When installing door releases with DC connections,the electric strike latch should notexert any pressure on the door-release latch.Incorrect installation could causedoor-release failure.62L8/14 V ac/dc(20 Ω 0,5 A a 12 Vac)6251M12 Vdc 100%(70 Ω 0,17A)FAIL-SAFEFAIL-SECURE6656N24 Vdc 100%(240 Ω 0,10A)FAIL-SAFEFAIL-SECURETemperature test:Measured on coil surface, tolerance ±10%Technical featuresElectric strikes with «ac» coils work properly even with a pressure up to15Kg.Waterproof mechanism boxWithstands impacts and pressures up to 300 Kg, getting destroyed at500kg.°CMinutes 5(a 12 Vac)300.000 guaranteed openings.Reinforced mechanism boxLow power consumption.Stainless steel screws.°CHours 5°CHours 5Other coils and voltages on demandProtected against water projected in all directions (IP54).Corrosion resistant according to UNI ISO 9227 StandardsComplies with electromagnetic compatibility standard 2004/108/CE(EN55014).25331325313145,573,5151340,58525045,573,527 27 2720131 45,5 73,51513140,52501340,585250Reversible Reversible Reversible12INOX 3mm 68 INOX 3mm 69 INOX 3mm 75Door HandednessDIN definition:The door is viewed from the side onwhich the hinges are visible.15


security electric strikesfor armoured doorsReferences and featuresAdjustablelatchPreloadElectronicprotectionVoltageReferencesDIN rightadd faceplateReferencesDIN leftadd faceplateFail-secureThe electric strike is locked when unenergized.8-14 V ac/dc12 V dc9R0.1.00.L9R0.1.00.M9L0.1.00.L9L0.1.00.M24 V dc9R0.1.00.N9L0.1.00.NFail-safeThe electric strike is locked when energized.12 V dc24 V dc9R4.1.00.M9R4.1.00.N9L4.1.00.M9L4.1.00.NInternal Hold-open with mechanical unlatchingThe electric strike has a an internal device that allows its opening with a single electrical impulse. Itremains in open position until the closing of the door and has mechanical unlatching.9-14 V ac/dc9R3A.1.00.L9L3A.1.00.LFail-secureFail-safeInternalHold-openOperationinternalhold-openDimensions88,5328336,32377D I D I DICoil featuresopenedclosedWarning:When installing door releases with DC connections,the electric strike latch should notexert any pressure on the door-release latch.Incorrect installation could causedoor-release failure.62L8/14 V ac/dc(20 Ω 0,5 A a 12 Vac)6251M12 Vdc 100%(70 Ω 0,17A)FAIL-SAFEFAIL-SECURE6656N24 Vdc 100%(240 Ω 0,10A)FAIL-SAFEFAIL-SECURETemperature test:Technical featuresDesigned for bolts-locked armoured doors.4mm. distance between the latch and the first bolt of the electric strike.Withstands impacts and pressures up to 400 Kg, getting destroyed at 700kg.300.000 guaranteed openings. Reinforced mechanism boxLow power consumption.Steel screws.FaceplatesMeasured on coil surface, tolerance ±10%353°CMinutes 5(a 12 Vac)Electric strikes with 12V ac coils are released by applying a pressureup to 16 kgCorrosion resistant according to UNI ISO 9227 StandardsComplies with electromagnetic compatibility standard 2004/108/CE (EN55014).Latch adjustment regulator (is supplied on demand)Stainless steel lock cover°CHours 5353°CHours 5Other coils and voltages on demandAdjustable latch (3mm)Standard adjustable latchRef. 1373724724714,210,868,568,5O 2034,8 6141,5141,5O 20Deep adjustable latchRef. 3ReversibleINOX 3mm 60ReversibleINOX 3mm 70Door HandednessDIN definition:The door is viewed from the side onwhich the hinges are visible.34,814,29,310,816


steel electric strikesfor RF-120 doorsUNE EN 1634-1, RF120References and featuresFixedlatchPreloadElectronicprotectionVoltageReferencesDIN rightadd faceplateReferencesDIN leftadd faceplateFail-secureThe electric strike is locked when unenergized.8-14 V ac/dc12 V dc24R0.4.00.L24R0.4.00.M24L0.4.00.L24L0.4.00.M24 V dc24R0.4.00.N24L0.4.00.NFail-secure with 1 microswitchIt works just like the Fail-secure model plus an electrical switching device that detects the status of the door.8-14 V ac/dc12 V dc24R6.4.00.L24R6.4.00.M24L6.4.00.L24L6.4.00.M24 V dc24R6.4.00.N24L6.4.00.NFail-safeThe electric strike is locked when energized.Fail-safe with 1 microswitchIt works just like the Fail-safe model plus an electrical switching device that detects the status of the door.12 V dc24 V dc12 V dc24 V dc24R4.4.00.P24R4.4.00.N24R8.4.00.P24R8.4.00.N24L4.4.00.M24L4.4.00.N24L8.4.00.M24L8.4.00.NFail-secureFail-safe1 microswitchFail-secureFail-safeOperationFail-secureFail-safeSchematic electricdiagram con microswitchlightNONCCOMD I D I D I D IopenedclosedclosedopenedPrincipalmicroswitchS1Dimensions29,59,220,53,545106,45211107PushbuttonDoor openedDoor closedCoil featuresPower supplyWarning:When installing door releases with DC connections,the electric strike latch should notexert any pressure on the door-release latch.Incorrect installation could causedoor-release failure.62L8/14 V ac/dc(20 Ω 0,5 A a 12 Vac)6251M12 Vdc 100%(70 Ω 0,17A)FAIL-SAFEFAIL-SECURE6656N24 Vdc 100%(240 Ω 0,10A)FAIL-SAFEFAIL-SECURETemperature test:Measured on coil surface, tolerance ±10%°C°C°CTechnical featuresMinutes 5(a 12 Vac)Hours 5Hours 5Other coils and voltages on demandHeat resistance: 1150 ° C for 2 HoursApproval standard UNE EN 1634 - 1, RF 120Stainless steel lock coverWithstands impacts and pressures up to 1000 KgFaceplates253300.000 guaranteed openingsReinforced mechanism boxStainless steel screwsLow power consumptionElectric strikes with 12V ac coils are released by applying a pressure upto 16 kgCorrosion resistant according to UNI ISO 9227 StandardsComplies with electromagnetic compatibility standard 2004/108/CE(EN55014).25390,544 65,55215944 65,552200Reversible49,561INOX66INOX3mm3mmDoor HandednessDIN definition:The door is viewed from the side onwhich the hinges are visible.17


symmetrical steel electric strikesHigh-security (1000 Kg)newReferences and featuresRadialturninglatchReversibleAdjustablelatchPreloadElectronicprotectionVoltageReferenceslatch (1)add faceplateFail-secureThe electric strike is locked when unenergized.8-14 V ac/dc5-12 V ac/dc250.1.00.B250.1.00.J12 V dc250.1.00.E24 V dc250.1.00.FFail-secure with 1 microswitchIt works just like the Fail-secure model plus an electrical switching device that detects thestatus of the door.8-14 V ac/dc5-12 V ac/dc12 V dc256.1.00.B256.1.00.J256.1.00.EFail-safeThe electric strike is locked when energized.24 V dc12 V dc24 V dc256.1.00.F254.1.00.E254.1.00.FFail-safe with 1 microswitchIt works just like the Fail-safe model plus an electrical switching device that detects thestatus of the door.12 V dc24 V dc258.1.00.E258.1.00.FHold-openThe electric strike has a device that allows its opening with a single electric impulse. It remains inopen position until the closing of the door.8-14 V ac/dc5-12 V ac/dc252.1.00.B252.1.00.JFail-secureFail-securewith microswithFail-safeFail-safewith microswithHold-openDimensions43,811,656211,6515,311,6511,6515,370280,578,528,543,820,520,5Coil featuresWarning:B8/14 V ac/dc(14 Ω 0,7 A a 12 Vac)J5/12 V ac/dc(8 Ω 0,6 A a 9 Vac)E12 Vdc 100%(50 Ω 0,25 A)F24 Vdc 100%(185 Ω 0,12 A)When installing door releases with DC connections,the electric strike latch should notexert any pressure on the door-release latch.Incorrect installation could causedoor-release failure.105655377Temperature test:Measured on coil surface, tolerance ±10%°C°C°C°CMinutes 5(a 12 Vac)Minutes 5(a 9 Vac)Hours 5 Hours 5Other coils and voltages on demandTechnical featuresElectric strikes with «ac» coils work properly even with a pressureup to 16Kg.300.000 guaranteed openingsSteel leversWithstands impacts and pressures up to 1000 KgSteel screwsLow power consumptionCorrosion resistant according to UNI ISO 9227 StandardsComplies with electromagnetic compatibility standard 2004/108/CE(EN55014).18


faceplatesfor symmetrical steel electric strikesnew25325332544 65,55215948,530,7549,5445211044 65,552200Reversible30,7590,5Reversible61INOX 3mm62INOX 3mmReversible66INOX 3mm333252525139,7548,579 35 442505261,7512139,7548,544102 12,525061,7512139,755248,54410212,52505261,7517ReversibleReversible63 D63 C63INOX 3mm 65 D65 C6564 D64 C6423425R 10R 101284890 122405248,5441725244641432R 10R 10ReversibleReversibleRightDINLeft73 INOX 3mm 7416BROWN17BROWN2322R 10R 10R 10R 1010210225025048,54412124452521212RightDINLeft322508 BROWN 0925RightDINLeftR 10R 10R 1012 BROWN 13R 1019


electromagnetic locksnewnewmicro electromagnetic locksmagnetic door holdersmini electromagnetic locksuniversal electromagnetic locksIP65 waterproof mini electromagnetic locks20shearlocks


4,539,5micro electromagnetic locksfor lockers, drawers, cabins, etcnewDimensions32,590MEX7024769,2BracketZ32,9For doors that open inwards753838Electrical connection38Power supply 12Vdc - 340mAMBAX70Power supply 24Vdc - 165mABracketUFor glass doors2816Holding force: 700 N4170MHAX7021


46,246,2magnetic door holdersnewReferencesDimensionsTechnical featuresDHI Industrial door holder24,77O 55O 50DHS Basic door holder6028O 50O 551560Diameter:50mm.Holding force: 600 NPower supply: 24 VdcElectric connexion: 2 wiresside or rear exit24Vdc consumption: 0,085 APower:2 W6060DHB Dual tension door holder83659046,2O 50555165Diameter:50mm.Holding force: 600 NPower supply: 12/24 Vdc12Vdc consumption: 0,170 A24Vdc consumption: 0,085 AVoltage change: with jumperPower:2 WPush button to unlock the door42 5,DHT Timed door holder836590O 50555165Diameter:50mm.Holding force: 600 NPower supply: 24 VdcTimer:3 seg.24Vdc consumption: 0,085 APower:2 WPush button to unlock the door42 5,DHD Door holder with power-regulation836590O 50555165Diameter:50mm.Max. Holding force: 600 NMin. Holding force: 300 NPower supply: 24 Vdc600N consumption: 0,085 APower:2 WPush button to unlock the door42 5,DFS Door holder support8339908339All models are equippedwith ejector pins to overcomeresidual magnetism192808022


mini electromagnetic locksReferences and featuresInstallationMortise RimFitting systemround squaredLedReedElectronicprotectionHoldingforceVoltage12/24 VdcReferences2800 NME-2002800 NME-2012800 NME-2102800 NME-2112800 NME-4002800 NME-4102800 NME-4202800 N x 2ME-6002800 N x 2ME-6102800 N x 2ME-620ReferencesPackaging dimensionsTotal weightElectric consumption12 Vdc 24 Vdc PowerME-200/2102492022630401051,8 Kg500 mA250 mA6 W305ME-201/2112623920230401051,8 Kg500 mA250 mA6 W305ME-400/410/4202653540202401051,8 Kg500 mA250 mA6 W305ME-600/610/6203152535401054 Kg500 mA250 mA6 W55023


ackets for mini electromagnetic locksReferences and featuresBrackets BracketsBracketsL Z Ufor outwardopening doorsfor inwardopening doorsfor glass doorsBrackets for mini electromagnetic locksMBE-806MBA-801MHA-804190263950265MBA-80250270505050Brackets for double mini electromagnetic locks Base for RF door Finish selection chartMBE-807 MRF-810 FSC-8211235505052518550265Wiring and voltage switchingVOLTAGE CHANGECorrect position of voltage selection jumpersJUMP CONNECTOR SET VOLTAGEJUMP CONNECTOR SET VOLTAGEDC POWER INPUTJUMP CONNECTOR SET VOLTAGEDC POWER INPUTDC POWER INPUTJUMPERSJUMPERVoltage selection pinsREED SWITCH FEATURES REED SWITCH CONTACTSLEDREED SWITCH CONTACTSDoor properly lockedMAXIMUM SWITCHING VOLTAGE 100 VDC (VOLTS DC)MAXIMUM SWITCHING CURRENT 0.3 A (AMPS DC)Door improperly locked(electric strike plate incorrectly positioned)MAXIMUM CONTACT RATING 3 W (WATTS DC)Electromagnetic lock out of order(failure on the electric power supply)Installation and features of the electric strike faceplateDOORWASHERDOORWASHERDOORWASHERARMATUREARMATUREARMATUREHEX BOLTSCREWSCREWHEX BOLTSCREWJOINTJOINTJOINTHex boltFixing the armature to a steel, PVC or aluminium profile.Armature fastening holesFixing the armature on armoured steel doors.The steel needs to be thick enough to fastenthe screw on the steel door.If the steel is not thick enough, the plate mustbe fastened with the hex bolt.Fixing the armature on a wooden door.D2Ø 5,5Ø 5,5Stringer3HWashersJointArmatureScrew2 JointsHex boltD1L1Screw2 WashersStringerBDoorThe parts shown above are delivered with each magnet.LThe armature must be fastened exactly as shown above.HOLDING FORCEMEASURESL B H L1 D1 D2Warning: Do not fasten the center screw too tightly. The plate must be loose.2800 N 185 35 12 165 17 924


universal electromagnetic locksReferences and featuresInstallationMortiseRim<strong>Security</strong>deviceLedReedTimer from2 to 8 sec.ElectronicprotectionHoldingforceVoltage12 VdcDual voltage12/24 VdcchangingautomaticallyReferences1800 NMEX-1003000 NMEX-2013000 NMEX-4003000 NMEX-4303000 N x 2MEX-6003000 N x 2MEX-6306500 NMEX-7006500 NMEX-7306500 NMEX-900Dimensions Packaging dimensions Total weightElectric consumption12 Vdc 24 VdcPowerMEX-1002240371201,2 Kg 250 mA 3 W166295MEX-2012282346371202,15 Kg 270 mA 3,3 W295248MEX-4002852371202,25 Kg 270 mA 180 mA 3,3 W295241MEX-4302852371202,25 Kg 270 mA 180 mA 3,3 W29524128MEX-60052374,4 Kg 270 mA 180 mA 3,3 W12052041728MEX-63052374,4 Kg 270 mA 180 mA 3,3 W120520417MEX-7003570504,1 Kg 270 mA 180 mA 3,3 W160308265MEX-7303570504,1 Kg 270 mA 180 mA 3,3 W160308265MEX-9002654065504,5 Kg 270 mA 180 mA 3,3 W16030831525


ackets and accessoriesReferences and featuresBrackets BracketsL ZBracketsUfor outwardopening doorsfor inwardopening doorsfor glass doorsBrackets for 180 Kg electromagnetic locksMBEX-18035166MBAX-180(3 units)4013545 45MHAX-1801352040404016626Brackets for 300 Kg electromagnetic locksMBEX-300MBAX-300(3 units)50160MHAX-3001602050 504035452405224033Brackets for 600 Kg electromagnetic locksMBEX-600MBAX-600(3 units)4018040265 7570756526543Installation and features of the electric strike faceplateDOORWASHERDOORWASHERDOORWASHERARMATUREARMATUREARMATUREHEX BOLTSCREWSCREWHEX BOLTSCREWJOINTJOINTJOINTHex boltFixing the armature to a steel, PVC or aluminium profile.Armature fastening holesFixing the armature on armoured steel doors.The steel needs to be thick enough to fastenthe screw on the steel door.If the steel is not thick enough, the plate mustbe fastened with the hex bolt.Fixing the armature on a wooden door.D2Ø 5,5Ø 5,5Stringer3HWashersJointArmatureScrew2 JointsHex boltD1L1Screw2 WashersStringerBDoorThe parts shown above are delivered with each magnet.LThe armature must be fastened exactly as shown above.HOLDING FORCEMEASURESL B H L1 D1 D2Warning: Do not fasten the center screw too tightly. The plate must be loose.1800 N 135,531,5 8,6 120 Ø10 Ø5,63000 N6000 N160 45,3 12,6 140175 62 13,6 150Ø16 Ø 9Ø16 Ø 926


IP65 waterproofmini electromagnetic locksReferences and featuresInstallation:RimChromefinishFitting systemsquaredReedElectronicprotectionHoldingforceIP65Voltage12/24 VdcReferences2500 NME-5002500 NME-510<strong>Product</strong> especially designed for outdoor installations. IP65 approval and total protection againstweathering.ReferencesPackaging dimensionsTotal weightCablelengthElectric consumption12 Vdc 24VdcPowerME-500401051,9 kg1100 mm.500 mA250 mA6 W305ME-510401051,9 kg1100 mm.500 mA250 mA6 W305Dimensions4 or 7 wires depending on the model4 drills D=5,2 for plain faced screws(DIN 965 or similar)ConnectionsME-500greyME-500grey12 V dcwithoutpolarityredblueyellow24 V dcwithoutpolarityredblueyellowME-51012 V dcwithoutpolaritywhiteredgreenyellowME-51024 V dcwithoutpolaritywhiteredgreenyellowblueblueNOblackNOblackcontactsrelay «REED»CNCbrowncontactsrelay «REED»CNCbrownBrackets for mini electromagnetic locksØ 5,5D2Ø 5,5MBE-80650265MBE-801D13H50L1BMBE-80834265MBE-802505027050HOLDING FORCEMEASURESLL B H L1 D1 D2342500 N 185 35 12 165 17 927


shearlocksfor swing and sliding doorsWhat is a shearlock and how it worksA shearlock is an electromagnetic lock that combines magnetic and mechanical force, generating a holding power of up to 15.000N.It can be installed on all kinds of left and right handed doors (metal, wooden and glass), either horizontally or vertically. It is the ideal lockfor swing doors and emergency doors equipped with panic devices.A magnetic sensor detects when the door and doorframe are aligned and makes the shearlock lock the door in place. When a sherlock isdeactivated via an access control system or a button, the door is released. If, however, the door is no physically open within the T1 programmedtime (closing delay), the shearlock will automatically lock the door again. Otherwise, the door can be kept unlocked for a specifictime simply by interrupting the power supply.Shearlocks operate on 10-36V dc, so the installer does not have to set the voltage. They have two power connections and an adjustabledelay system, which means a delay between 1 and 25 seconds for realease and locking can be set.Shearlocks are designed to be connected for instant-release buttons, traffic lights, access control systems, radio alarms and even heat andsmoke detectors, in order to release the door immediately in case of fire.Example of useThere is an attempted robbery in a department store and the thief tries to escape through an emergency door with a panic device and ashearlock.When the thief pushes the panic bar, the door will still be locked by the shearlock for the programmed time, and a warning signal can besent to the store’s emergency control center. If the system is equipped with an acoustic alarm, it will be ringing for the time the shearlock isprogrammed to. When the thief discovers the door is locked, he will be forced to drop the goods.Once the door is released, the store’s security personnel will have to reset the shearlock to stop the alarm and reset the system.Different installation possibilitiesA) RimDimensionsRimModel: SH100SilverDoor only opensone waySwing doorB) MortiseMortiseDoor only opensone waySwing doorModel: SH200GreyC) Glass and swing doorsGlass doorABABMixed installationMixed installation28Shearlock for glass doorModel: SH300A) Shearlock surface mountedB) Shearlock glass doorModel: SH400A) Shearlock built-inB) Shearlock glass doorModel: SH500


Model SH-100Model SH-200Warning:Maximun space between parts = 3 mmElectrical features:Power supply:10-36 V dc, there is no need to set the voltageConsumption for 12 V dc 2A startup and 0,5 A operating current.Coil:Tropicalized.Autoprotection:If the closing manoeuvre is not executed correctly because there is a defect inalignment or there is an object preventing closure, the system tries to close severaltimes. If after five attempts the shearlock cannot be closed, it remains in theopen position and triggers an alarm. This prevents the product from overheating,which causes the deterioration of the product.Power supply connectionLEDT2 Release-delay adjustmentFOR PANIC DEVICEST1 Locking-delay adjustmentAuxiliary relay:Inversion circuit. Maximum current: 1 A at 24 V dc.When activated, the door is locked.When deactivated, the door is released.Time delays:When locking/ aligning: 4 sec. ( adjustable from 0 to 25 sec )When releasing/ in an emergency: 15 sec ( adjustable from 0 to 25 sec )The adjustments can be independent from each other. Values shown are factorydefault settings.Additional features:Locking prevention: this connection keeps the door released, even though thepower is connected.Opening delay: either through an instantaneous connection or a button withtimed opening.Alarms:Intermittent alarm:The electromagnet and door plate are not aligned.Attempted forced entry.Coil malfunction.Position sensors not aligned.Alarm indications are cancelled after 15 sec. or disconnecting the powersupply.Continuous alarm:Indicates the countdown to door release.Deactivates through the locking-prevention system or by disconnecting thepower supply.3 color LED indicator:Green: door released.Red: door closed.Amber: malfunction or transitory state.1 A at 24 VMagnetic alignmentsensorsPower supply (10 to 36 VDC)Emergency release delayAuxiliary ( - )Alarm ( - )RelayTransistor within the shearlock’s own electronic circuitImmediate release and reset auxiliary ( + )External alarm circuit:4 + Common with the shearlock8 - Auxiliary through the transistor in the shearlock circuitMaximum current: 350mAPulsador apertura instantánea y reset4 + Common with the shearlock3 Active29


shearlocksfor glass doorsModel: SH-300Warning:Maximum space between parts = 3 mmInstallation instructions1) Ensure the separation between the two glass plates (fixed part and moving part) is 6,5 mm or more.2) Install the two parts of the shearlock so they are perfectly aligned and parallel.3) For the sensor to detect when the door is closed, the separation between the two parts of the shearlock should not exceed 3 mm.LOCKINGM6 allen key (2 units)3 mm spannerSET SCREW FOR BERING STRIPFOR THE GLASS (2 units)M6 allen key3 mm spannerBERING STRIPFOR THE GLASSINSTRUCTIONSAdhesive strip withprotective backing1. Remove the protective backing.2. Put the bracket in place.3. Remove the two locking screws.4. Use the set screw to push the bearing strip forward until it exerts pressure on the glass.5. Insert and tighten the locking screws until they lock into the set screws.Installation examplePower supplyHydraulicspringTraffic lightCoded access controlAC-100Traffic lightPower supply from 10 to 36 VdcMaximum current: 2,5 A at 10 VOperating current: 0,5 A at 10 VStabilized direct currentObserve connection polarity30


other products and accessoriesnewnewnewtraffic lights for access control systemsflex tube and jointsprovisional latchpower suppliesmotorized RIMTOPLOCK31


traffic lights for access control systemsnew10-24 V ac/dc(flashing or steady light mode)10-24 V ac/dc(flashing or steady light mode plus audiblewarning device)2 LEDS(Red and green)2 LEDS(Red and green)+ push button2 LEDS(Red and green)+ audible warning device2 LEDS(Red and green)+ push button+ audible warning deviceTLX001 TLP002 TLB001 TLB002Jumper operationElectrical connectionNon polarized power supplyGreen LED contact10-24 Vac / dc COMRed LED contactwithout jumperThe audible warning deviceand the LED light remains inflashing mode.with Jumperthe audible warning device andthe LED light remains in steadymode.Traffic lights dimensionsBox dimensions404,5110129,5801140 408018,626142232


3939flex tubes and jointsnewReferences and featuresModelDiameter Finish color Flex tube lenght Total lenghtEFX15014,5 mmSteel150 mm250 mmSFX25014,5 mmSteel150 mm250 mmSFX42014,5 mmSteel320 mm420 mmSFX60014,5 mmSteel500 mm600 mm47BFX300G14,5 mmGrey boxSteel Flex tube200 mm300 mm22BFX500G14,5 mmGrey boxSteel Flex tube400 mm500 mm47BFX300B14,5 mmBrass boxSteel Flex tube200 mm300 mm22BFX500B14,5 mmBrass boxSteel Flex tube400 mm500 mmDual electrical jointsElectrical featuresDDC002Maximum voltage: 24 V ac/dcMaximum intensity: 1,5 A. ac/dc58670116111333


provisional latchesnewFor faceplates located on building sitesDuring construction work, it is possible to install a provisional latch CSR 001 that will leave the faceplate ready for the installation at thecorresponding electric strike.The latch replacement CSR 001 allows to keep the doors closed during the construction process, and is supplied with the 3 mm adjustablelatch.The CSR001 provisional latch can be installed in allOPENERS & CLOSERS faceplatesProvisional latch CSR001(3mm adjustable)Dimensionsfaceplate 03faceplate 03 + CSR00112,612,644,752,35,434


power suppliesReferences and featuresPower supplies at DC currentInput Output Output Stability Protection Degree Power Battery Battery Capacity ReferencesVoltage Voltage Current Charge230 V 50/60Hz 12 V dc 6 A dc 3% IP20 80 W yes PS 901*230 V 50/60Hz 24 V dc 3 A dc 3% IP20 80 W yes PS 902*230 V 50/60Hz 12 V dc 6 A dc 3% IP20 80 W yes 12 V dc 7 Ah PS 905**230 V 50/60Hz 24 V dc 3 A dc 3% IP20 80 W yes 24 V dc 4 Ah PS 906**230 V 50/60Hz 12 V dc 3 A dc 3% IP20 30 W PS 907*230 V 50/60Hz 24 V dc 1,5 A dc 3% IP20 30 W PS 908*High efficiency (77-87%) switching power supplies.Temperature operation between 0° - 40°CSingle output, over voltage, over heating and short circuit protection.Double function: power supply and batteries charging “on line” system, with complete discharge protectionPower supply at AC current230 V 50/60Hz 12 V ac 1,5 A ac IP20 18 VA PS 903** Finish DIN rail 35 x 7.5 ( DIN 500 22 )** 4 terminals for 2 electromagnetic locks each, with switches and operation warning light controls.PS 901PS 907 PS 905PS 902PS 908PS 906PS 90335


motorized RIMTOPLOCKGeneral operation:When the door is aligned with the frame, the magnetic detector located at the (front) lock box, blocks thedoor.Once the lock is released, and during the scheduled opening time, the lock makes an intermittent warningsound. After a scheduled time, the lock blocks automatically.An acoustic alarm warns when the door is not properly closed.CE-104Features and functional description• Mechanical opening handle• Push button for electrical opening• External cylinder for key opening• Reversible, 60 mm cylinder• 12 V dc power supply• 500mA energy consumption• 350.000 guaranteed openingsENTRY:EXIT:1) Access control opening2) Key opening1) Electrical opening using the red push button2) Electrical opening using access control3) Mechanical opening using lock handleIN CASE OF ELECTRICAL POWER CUT OFF:1) Entry with keys2) Exit using lock handleCE-105Features and functional descriptionThe lock remains in permanent unblock position pressing the green button. The lock becomes operative againwith a second press, which cancels the permanent unblock.CE-106CE-109VCX-100• Mechanical opening handle• Push button to lock / unlock permanently• External cylinder for key opening• Reversible, 60 mm cylinder• 12 V dc power supply• 500mA energy consumption• 350.000 guaranteed openingsFeatures and functional description• Mechanical opening handle• External cylinder for key opening• Reversible, 60 mm cylinder• 12 V dc power supply• 500mA energy consumption• 350.000 guaranteed openingsFeatures and functional description• Internal and external cylinder for key opening• Reversible, 60 mm cylinder• 12 V dc power supply• 500mA energy consumption• 350.000 guaranteed openingsRain-protection steel visorENTRY:EXIT:ENTRY:EXIT:1) Access control opening2) Key opening1) Electrical opening using access controlor pressing the button2) Mechanical opening using lock handleIN CASE OF ELECTRICAL POWER CUT OFF:1) Entry with keys2) Exit using lock handleENTRY:EXIT:1) Access control opening2) Key opening1) Electrical opening using access controlor pressing the button2) Mechanical opening using lock handleIN CASE OF ELECTRICAL POWER CUT OFF:1) Entry with keys2) Exit using lock handle1) Access control opening2) Key opening1) Electrical opening using access controlor pressing the button2) Mechanical opening using keysIN CASE OF ELECTRICAL POWER CUT OFF:1) Entry with keys2) Exit with keys9442Dimensions and electric diagramLock MotorLock Motor100968040GreenExteriorpushbuttonGreenPushbuttonRedRed129,558Door sensorLock switchpush buttonDoor sensor5541aBlue (-)Red (+)12V dc36Warning:a126The distance between the electric strike and the front box should be 5 mm.Distance plastic controller included.


In the interest of improving the quality of our products,Openers & Closers reserves the right to modify or updatethe information provided in this catalogue.37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!