3. MAINTENANCE<br />

Fig 17. Put one <strong>of</strong> the pin screws into the hole <strong>of</strong><br />

the spacer sleeve (19) and turn it gently. Knock<br />

also carefully with a plastic hammer to easier<br />

force down the spacer sleeve.<br />

3.6.4 Main unit assembly<br />

Fig 20. Make sure all pin screws (14) have one<br />

nut (37) and one washer (38) each. Nut should<br />

only be put on one or two threads. Put the pin<br />

screws through the housing and the stainless<br />

steel side plate and mount carefully the center<br />

block assembly.<br />

Instruction manual TF PE & PTFE series pumps 17<br />

Fig 18. Make sure the seat and sleeve assembly<br />

is flat inside the housing.<br />

Fig 21. Put the small o-ring (pos 18) in the seat <strong>of</strong><br />

the housing. On pumps with PTFE diaphragms<br />

the PTFE u-ring with its o-ring shall be mounted<br />

with o-ring facing upwards (see Fig. 21).