<strong>Wind</strong> Farm Solution | Connection <strong>to</strong> the GridAchieving improved reliabilityand efficiency at once97%The amount ofavailability SchneiderElectric can guaranteefor your wind farminstallation.25%The reductionin operating andcapital expensesyou can realizethrough powerfac<strong>to</strong>r correction/harmonic mitigation.A solution <strong>to</strong> connect you <strong>to</strong> the gridand extend the life of your equipmentConnecting <strong>to</strong> the power grid brings withit a unique set of challenges: surges, dips,dis<strong>to</strong>rtions, and, of course, stringent grid coderequirements. Even small shifts of power flowscan trip circuit breakers, sending larger loadson<strong>to</strong> neighbouring lines and causing chainreaction failures.For those not from electrical backgrounds,solving these problems can be a dauntingproposition. And yet, bringing clean,reliable power <strong>to</strong> your installation isabsolutely necessary.Fortunately, being the global specialist inenergy management, we at Schneider Electrichave the solution — the solution <strong>to</strong> relievethat grid-induced anxiety, bring you theoptimized reliability you need, andguarantee 99.5 percent availability.The solution begins with SF6 insulatedmetal-enclosed switchgear, which isdesigned <strong>to</strong> ensure maximum safety ina reduced-space environment. Its designalso ensures that it is unaffected by theenvironment, enabling a superior continuityof service.In terms of grid code requirements, we designand provide everything you need <strong>to</strong> comply,from fixed LV and MV power fac<strong>to</strong>r solutions<strong>to</strong> real-time compensation systems. Thesesystems, which include harmonic mitigation,provide several benefits that can be translateddirectly in<strong>to</strong> financial savings for both theinves<strong>to</strong>r and the user:>> Up <strong>to</strong> 25 percent reduction is commonlyachievable in both capital andoperational expenses>> Significant reduction in downtime>> Extended equipment lifetime>> Minimized system lossesand demand power>> Reduced overloading on the electricalsystem, thereby releasing useable capacityAll this adds up <strong>to</strong> improved competitivenessof your business. And, since such measuresare now all but essential for operating a safeand successful installation, the time has neverbeen better <strong>to</strong> take these precautions againstan unreliable grid.<strong>Bringing</strong> clean, reliable power <strong>to</strong> yourinstallation is absolutely necessary.16 | Schneider Electric Solutions for <strong>Wind</strong> <strong>Power</strong>
ProductsPrimary SwitchgearsReactive Energy Compensation<strong>Power</strong>TransformersCGset• Single busbar/double busbar• 24kV-36kV• Up <strong>to</strong> 2500A• Up <strong>to</strong> 40kA 3s• 31,5kA / 1s -40kA / 0,5s IACAFL - AFLR.MCset• 24kV• Up <strong>to</strong>2500ALV CompensationVarset• Up <strong>to</strong> 800 V• 50 and 60 Hz• Indoor or outdoorMV CompensationCP200 series• UP <strong>to</strong> 36 kV• 50 and 60 Hz• Indoor or outdoorDynamicCompensationAccusine• Up <strong>to</strong> 10 MVar,with parallelconnections• LV and MVcompensation (MVachieved throughtransformer)• 50 and 60 Hz• Up <strong>to</strong> 123 kV - 60MVA• Vegetable ormineral oil• On-load or off-loadtap changers• Adaptable design forcapitalization of lossSchneider Electric Solutions for <strong>Wind</strong> <strong>Power</strong> | 17