PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENTCertificated Products020-772 4-way monitored sounder kitLPCB Ref.No.Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B8.9 Output to fault warning routing equipment10 Test conditionZircon 4 Zone 002-509-249 Bardic Zircon, 4 zone, region 2, black grey 154g/07Incorporating the following units:020-747 8-way relay kit020-772 4-way monitored sounder kitCertified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B8.9 Output to fault warning routing equipment10 Test conditionZircon 8 Zone 002-509-289 Bardic Zircon, 8 zone, region 2, black grey 154g/08Incorporating the following units:020-747 8-way relay kit020-772 4-way monitored sounder kitCertified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B8.9 Output to fault warning routing equipment10 Test conditionBiamp Systems Corporation9300 S.W. Gemini Drive, Beaverton, Oregon 97008, USATel: +1 503 718 9212 • Fax: +1 503 626 0281Website: www.biamp.comCertificate No: 977a to EN 54-16: 2008Certificated ProductsVocia VACIEVoice Alarm Control and Indicating EquipmentIncorporating:LSI-16 / LSI-16e Life Safety Interface:700-P630-9 LSI-16 / LSI-16e Main Board700-P632-9 LSI-16 / LSI-16e Display Board700-P675-9 IM-16 Input Module700-P644-9 LSI-16 / LSI-16e Power Supply BoardLPCB Ref.No.977a/0132 18 Jan 2014

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!