AutosamplersPart no.Description181.0037 Autosampler AS 100, cool, micro, 6-PV181.0038 Autosampler AS 100, cool, micro, 10-PVSpecifications Autosampler AS 100General specifications Power 115 or 230 VAC ± 10%, 50/60 Hz, 250 VA maxOperating conditionsSample capacityVial dimensionsDispenserWetted partsLoop volumeInjection10 - 35°C, 20 - 80% RH, non-condensing160, 96, 72 or 32 vials (20, 12, 9 or 4 per segment)7, 12, 15, or 22 mm vial diameter min/max height: 32/46 mm(including cap) micro vial inserts for micro dialysisSyringe: 100, 250 (st<strong>and</strong>ard), 500, 1000 μL, or 10 mLSS316, PTFE, TEFZEL, VESPEL, glass, PEEK, silica5 μL - 1 mL (1, 2, 5 steps), 100 μL st<strong>and</strong>ardPre-puncturing septa/caps with air needle, dual needle design,vial & height detection by vial sensorAnalytical performance Fool loop RSD < 0.3% (all specs for capped <strong>and</strong> sealed vials)Partial loop fillRSD < 0.5%, injection volumes > 5 μL, with headspacepressure on the vial <strong>and</strong> 30 μL pre-flush with air segmentµL Pick-up RSD < 1.0%, injection volumes > 5 μL, with headspacepressure on the vialCarry-over< 0.01% with programmable needle washProven <strong>analyzers</strong> to guarantee your performance®Injection programming Methods Full loop, partial loop <strong>and</strong> μL pick-up, user defined programmingVolumes1 μL - 1 mL (method dependent)InjectionsVial, volume, repetitions: freely programmable in dataacquisition softwareWashProgrammable needle washConnections Outputs Marker TTL <strong>and</strong> contact closures: inject, vial, labelled vial,stop I/O; programmable: 4 TTL, 4 relays contacts no/nc,2 relays contacts no/nc, 4 TTL time based; alarmInputsNext injection, next vial, freeze, stop, 4 TTLPC controlRS232C, full control with data acquistion softwareOptions Sample cooling 4 - 40°C; accuracy: ± 2°C capacity: ambient - 20°C(measured on cooling tray)Micro optionOptimized for small injection volumes > 1 μL; with 5.3 μLneedle, 20 μL loop <strong>and</strong> 100 μL syringe volume, μ-bore valvePhysical specifications Dimensions 54 (D) x 28 (W) x 44 (H) cm21.3” (D) x 11.0” (W) x 17.3” (H)Weight22 kg (48 lbs), 30 kg (66 lbs) incl. cooling option18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!