11.07.2015 Views

Sun Fire E25K Server datasheet - Spectra

Sun Fire E25K Server datasheet - Spectra

Sun Fire E25K Server datasheet - Spectra

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DATASHEET<strong>Sun</strong> <strong>Fire</strong> <strong>E25K</strong><strong>Server</strong>Key Feature Highlights• Delivers up to 5 times theperformance of UltraSPARC IIIservers and nearly double theperformance of UltraSPARC IVservers in the same footprint.• Scales up to 72 processors with144 threads and up to 576GBmemory for heavily threadedcommercial applications.• Unique Solaris OS applicationcompatibility guarantee enablesseamless migration to newer processortechnologies.• Mix and match UltraSPARC IV+, IV, and IIIprocessors in the same system for in-chassisupgrades to faster processors, withoutforced hardware migrations.• Unique Uniboard technology commonacross <strong>Sun</strong> <strong>Fire</strong> E4900–<strong>E25K</strong> servers enablesprovisioning of extra resources whenrequired.• New RAS and security capabilities furtherenhance system uptime. Predictive Self-Healing predicts and prevents faultsautomatically.• Unique Dynamic Reconfiguration capabilitysaved customers nearly 1000 hours ofplanned downtime, for a conservative estimateof $47M savings in one 90-day period.• Dynamic System Domains technology—electrically fault-isolated hard partitions—and Solaris Containers can increaseutilization up to 80%, making this anideal platform for consolidation.• Respond flexibly to changing businessrequirements with Capacity onDemand for “pay as you grow”computing options.


2Datasheet <strong>Sun</strong> <strong>Fire</strong> <strong>E25K</strong> <strong>Server</strong>sun.com/servers/highend/sunfire_e25k<strong>Sun</strong> <strong>Fire</strong> <strong>E25K</strong> <strong>Server</strong> SpecificationsProcessorNumber Up to 72Architecture1.5GHz UltraSPARC IV+ and/or1.05GHz/1.2GHz/1.35GHz UltraSPARCIV and/or 1.2GHz UltraSPARC IIIprocessors; Superscalar SPARC V9,ECC protectedCache per processor Level 1: 64 KB data and 64 KBinstruction per pipelineLevel 2: 2 MB on-chipLevel 3: 32 MB externalSystem interconnect 150 MHz <strong>Sun</strong> <strong>Fire</strong>plane redundant18x18 data, address, and responsecrossbar interconnectSystemProcessor/memory boards Up to 18 Uniboard CPU/memoryboards with four processors each,and up to 32 GB per board; maximum576 GB per domainI/OUp to 72 hot-swappable PCI+ I/O slots;54 slots are 66 MHz; 18 slots are 33MHz; supports 10/100 BaseT Ethernet,Gigabit Ethernet, UltraSCSI (LVD andHVD), ATM, FC-AL, and HiPPIStorageStandardPerformance250+ TB direct connect storage—Fibre Channel (1 GB and 2 GB) andUltraSCSI. For boot: <strong>Sun</strong> StorEdge3120, <strong>Sun</strong> StorEdge S1, <strong>Sun</strong> StorEdgeD240, <strong>Sun</strong> StorEdge 3510, <strong>Sun</strong>StorEdge 3310, , and <strong>Sun</strong> StorEdge9990. Direct attach to <strong>Sun</strong> StorEdgetape libraries and disk arrays, including:<strong>Sun</strong> StorEdge 3000, 6000, and9000 families, providing excellentlinear scalability.Overall system bandwidth Up to 172.8-GB/sec. aggregate, up to115.2-GB/sec. peak, up to 43.2-GB/sec.sustainedOverall I/O bandwidth Up to 25.2-GB/sec. sustainedAvailabilityStandardSecurityDomain managementHot-swap CPU, memory, I/O, power,fans, online upgrades, journaling filesystem, redundant network connections,redundant storage connections,hardened operating system kernel,hardened I/O driversDedicated network connections(SC to 18 domains) inside <strong>Sun</strong><strong>Fire</strong>plane interconnectResource ManagementStandardSoftware<strong>Sun</strong>’s fifth-generation Dynamic SystemDomains, Solaris Resource Manager,and Bandwidth ManagerOperating system The minimum OS version for 1.5GHz(minimum version) UltraSPARC IV+ processors is Solaris 99/05 and Solaris 10 3/05 HW1The minimum OS version forUltraSPARC IV processors is Solaris 82/04, Solaris 9 4/04, and Solaris 103/05LanguagesC, C++, Pascal, FORTRAN, JavaNetworkingONC/NFS, TCP/IP, <strong>Sun</strong>Net OSI,X.25 Start, DCE, NetwareSystem management <strong>Sun</strong> MC 3.5 Version 4; SMS 1.4.1(or later)Network/file system <strong>Sun</strong> QFS, <strong>Sun</strong> ZFS (future Solaris 10release), VERITAS Volume Manager,VERITAS File SystemEnvironmentalAC power200–240 single-phase VAC, 47–63 Hz.Two N+1 power grids, each usingsix 30-Amp circuits. Second powergrid provided for redundancyOptimum22° C (72° F) at 45% noncondensinghumidityRange 10° C to 35° C (50° F to 90° F) at 20%to 80% noncondensing humidityAltitudeUp to 3048 m (10000 ft.)Regulations (meets or exceeds the following requirements)SafetyAdditional PowerSupply SafetyEmissionsImmunityRegulatory markingsUL 60950, USACAN/CSA-C22.2 No 60950, CanadaEN 60950, EuropeGOST-R, RussiaCB Scheme with national differencesS Mark, ArgentinaCCC, ChinaEN55022, EuropeEN61000-3-2 & 3-3, EuropeFCC Class A, USAICES-003 Class A, CanadaVCCI Class A, JapanCNS-13438 (BSMI), TaiwanAS/NZ 3548 (C-tick), AustraliaGost-R, RussiaMIC, KoreaAll European requirementsEN55024EN61000-4-2, -4-3, -4-5, -4-5, -4-6, -4-8,-4-11, EN300-386FCC, ICES-003, CE, C-tick, VCCI, GOST-R,BSMI, UL/cUL, TUV-GS, MICKey RAS FeaturesFull hardware redundancy, fault-isolated Dynamic SystemDomains, Dynamic Reconfiguration (DR), auto diagnosis andrecovery, proactive self diagnostics, online upgrades, concurrentmaintenance, end-to-end data integrity including ECC, redundantnetwork connections, redundant storage connections,kernel hot patching, hardened operating system kernel, liveoperating system upgrades, journaling file system, hardenedI/O drivers, CPU off-lining, memory page retirement, after-kernelhot patching, and cluster support.UpgradesThe <strong>Sun</strong> Upgrade Advantage Program (UAP) offers trade-in valuefor qualified <strong>Sun</strong> and competitive servers toward the purchaseof replacement <strong>Sun</strong> <strong>Fire</strong> <strong>E25K</strong> server(s). Whether upgrading onesystem or consolidating many systems to one, <strong>Sun</strong> UAP offersthe flexibility to trade in and receive credit toward the new <strong>Sun</strong>system purchased. Upgrades are also available for <strong>Sun</strong> <strong>Fire</strong> serversystem components, including processor/memory boards and I/O.Dimensions and WeightHeightWidthDepthWeightRemote ServicesSRS Net ConnectServices191 cm (74.75 in.)85 cm (33.25 in.)166 cm (65.0 in.)1122 kg (2468 lb.) fully configured<strong>Sun</strong> provides a worldwide services portfolio that helps enablecustomers to develop a <strong>Sun</strong> <strong>Fire</strong> <strong>E25K</strong> solution designed forreliability, availability, serviceability, and growth. <strong>Sun</strong> canassist you to build an architecture plan, assess your current ITinfrastructure, improve staff skills and efficiencies, and properlyinstall your <strong>Sun</strong> <strong>Fire</strong> <strong>E25K</strong> system in your environment. Serviceshighlights include: <strong>Sun</strong> Preventive Services, EnterpriseInstallation Services, Learning Services, Architecture Services,Migration/Consolidation Services, <strong>Sun</strong> Managed Services, andthe Accredited Installation Provider program. For more informationon <strong>Sun</strong> Services, please visit www.sun.com/service.Get the details on how the <strong>Sun</strong> <strong>Fire</strong> <strong>E25K</strong>combines high-volume, mission-criticalcomputing with leading investmentprotection and headroom to grow.Contact your <strong>Sun</strong> Representative at1-800-555-9SUN, or visit sun.com/servers/highend/sunfire_e25k.<strong>Sun</strong> Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-650-960-1300 or 1-800-555-9SUN Web sun.com©2005 <strong>Sun</strong> Microsystems, Inc. All right reserved. <strong>Sun</strong>, <strong>Sun</strong> Microsystems, the <strong>Sun</strong> logo, <strong>Sun</strong> <strong>Fire</strong>, Java, ONC, OpenBoot, Solaris, Solstice, Solstice DiskSuite, and <strong>Sun</strong>Screen are trademarks, registered trademarks, or servicemarks of <strong>Sun</strong> Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc., in the United States andother countries. Other brand and product names are trademarks of their respective companies. Information subject to change without notice. 10/05

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!