11.07.2015 Views

AC SIMDIS Solutions - ROFA Praha sro

AC SIMDIS Solutions - ROFA Praha sro

AC SIMDIS Solutions - ROFA Praha sro

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

www.simdis.com2Complete Range of Applications<strong>AC</strong> Analytical Controls (<strong>AC</strong>), the global <strong>SIMDIS</strong> market leader,provides solutions that accurately determine true boiling pointdata – from naphtha up to crude oil samples.• Full range of <strong>SIMDIS</strong> applicationsdetermine boiling points up to C120• Product range includes several uniquesolutions:- <strong>AC</strong> 8634 analyzer for acceleratedD 86 data of jet fuel and diesel- Crude Oil analyzer Merges DHA FrontEnd with High Temp <strong>SIMDIS</strong> Technique- Sulfur and Nitrogen <strong>SIMDIS</strong> solutionsto determine Hydrocarbon, Sulfur andNitrogen BP distributions in a singlerun- Wax ASTM D 5442 application• Dedicated correlations and calculationsare available for:- Correlation to Physical DistillationD 86 & D 1160 (ASTM D 2887; IP 406;ISO 3924)- NO<strong>AC</strong>K - DIN 51.581-2- MOV - ASTM D 6417- Conversion to volume % for crude oil- Cutpoints & fractions- Flashpoint (ASTM D 7215)• Excellent LIMS connectivity: upload theresults directly to your LIMS or manuallyafter approval• <strong>Solutions</strong> comply with ASTM, CEN, DIN,IP and ISO <strong>SIMDIS</strong> methods• A broad set of calibration, reference andquality control samples completes each<strong>SIMDIS</strong> application• User group meetings allows users toimprove analyzer performance• <strong>SIMDIS</strong> software is compatible withmajor chromatographic data systems• <strong>AC</strong> software puts the instrument instandby mode after analysis, to savegas and keep the instrument in optimalcondition• Several features contribute to theanalysis precision:- Use of pre-programmed sample types- Automatic blank subtraction,calibration and system validation- Customer selective start and endalgorithmVersion 6,1,0,0simdi s IP PM-CF-98 2Sample name : REFAcquired on : 3/9/01 4:05:16 PM Vial : 103Processed on : 6/11/01 7:52:35 AM Injection : 1Data File : HT750A\103F0401.DGeneral VariablesUsed BlankHT750A\101F0201.DUsed BP calibrant HT750A\102F0301.DUsed ReferenceUsed Start elution (min) 5.005Used End elution (min) 30.452Total area 173938New Response factor 5.7492e-006SignalReference CheckRecovered Target Values Determined Valuesmass % BP °C dBP °C BP °C dBP °C10.0 421.0 3.5 420.8 0.020.0 437.0 3.5 436.6 0.530.0 448.0 3.5 447.0 1.040.0 457.0 3.5 456.0 1.050.0 464.0 3.5 464.5 -0.560.0 473.0 3.5 472.5 0.570.0 481.0 3.5 480.7 0.580.0 489.0 3.5 489.6 -0.590.0 501.0 3.5 501.4 -0.5Maximum Squared Deviation = 43FoundMaximumSquaredSquaredDeviationDeviation= 434Squared Found Squared test passed Deviation = 4Squared test passedRetention Time (min)<strong>AC</strong> High Temp <strong>SIMDIS</strong> analysis of a reference sample

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!