11.07.2015 Views

Datasheet - Equipco

Datasheet - Equipco

Datasheet - Equipco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A SINGLEA SINGLESTROKEOF GENIUSPRECISION GAS DETECTION SYSTEM®


“Undoubtedly the most durable, userfriendly and versatile gas detection pumpon the market.” That’s something we hearall the time from customers and industryexperts alike: The Sensidyne system is thesimplest gas detection system to use. Andwe at Sensidyne are proud to be able tooffer the health and safety industry thisstreamlined, easy-to-use and vitallyaccurate product.Sensidyne’s products are used around theworld, which means that the health andsafety of millions of people are in manyways dependent on us. We take thisawesome responsibility seriously, andtherefore are committed to providing theindustry products and customer servicethat are unparalleled in quality andconsistency. That is our promise. That isour guarantee.– Carl Mazzuca,Sensidyne PresidentThe EssentialsSafety, precision, ease, speed, and durabilityare the gas detection systemessentials required by health andsafety professionals. The streamlinedSensidyne pump provides these essentialsand more. . .• Single-stroke operation brings timesavingease of use to gas detection.• A slender ergonomically designed,sure-grip shape; lightweight, and corrosion-resistant.• Piston-type volumetric pump assuresaccuracy every time.• Fail-safe handle lock in two positions(50 ml or 100 ml) which virtuallyeliminates incomplete samples thatcan occur with squeeze-type pumpswhen they are not fully collapsed.• Flow finish indicator.• High precision direct reading detectortubes for nearly 300 substances.• Clear indication of concentration levelof the substance being measured isshown by the length of the stain onthe glass tube. The measurement isprecisely recorded for direct readingon a single calibration scale.• No laboratory turnaround time, nopower requirement, and no user calibrationneeded.• Ease and simplicity of use saves trainingtime (training video available),sampling time, and provides a moreaccurate analysis.• A lifetime warranty, thus ensuringyears of dependable, trouble-free operation.No other system offers the Sensidynepump’s combination of superior featuresand benefits.Principles of OperationEach detector tube contains a reagentthat is specifically sensitive to a particularvapor or gas.These reagents are on fine-grain silicagel, activated alumina or other absorbingmedia (depending upon applicationrequirements), inside a constantinner diameter, hermetically sealedglass tube.Most Sensidyne detector tubes are the“direct-reading” type, with calibrationmarkings right on the tube, so measurementscan be made as simply andprecisely as reading a thermometer.The actual operation is simple and accurate.Just snap off both “breakaway” ends of a tube in the convenienttube-tip breaker, insert the tubeinto the hand held pump, and pull outthe pump handle. And that’s it.As the handle is pulled (just like asyringe), a precisely measured volumeof ambient air is drawn inside the tubewhere it contacts the reagent.Instantly, the reagent changes color.The reagent reacts quantitatively toprovide a length-of-stain indication.The farther the color stain travelsalong the tube, the higher the concentrationof gas. Note the scale mark onthe tube where the stain stops andthat’s the measurement.Model AP-1S Gas Detection Pump Kit PNº 7013585It’s safe, precise and fast. A SingleStroke of Genius.


Features & BenefitsSingle Stroke OperationThe Sensidyne pump is the easiestpump to use. There are no repetitiveoperations to obtain an accurate sampleevery time. One stroke is all it takes.Flow Finish IndicatorTiming the stroke is not necessary.The Flow Finish Indicator tells you automaticallywhen the stroke is complete.It operates from the pump’s internalvacuum for total reliability.High Quality Detector TubesSensidyne’s detector tubes are machinemade to the highest factory tolerances.This assures optimum repeatability fromone production lot to the next at a levelthat is unmatched by hand made tubes.Both the factory site and the U.S. distributionsite are ISO 9000 certified fortotal confidence in quality.AccuracyCalibration scales for the detectortubes are printed on the basis of individualproduction lots. This eliminatestroublesome variations in tube diameters,packing precision, and/or reagentquality or reactivity.Calibration scales are in ppm, mg/l, or%, depending on the substance to bemeasured and the desired measuringrange. Every tube box carries the qualitycontrol number and chemical symbol.The expiration date is prominentlystamped on each box.Expandable Measuring RangeThe calibration curve on most of theSensidyne detector tubes is a straightline, and points on the scale are atequal intervals. This means you canmeasure concentrations above or belowthe printed scale by simply increasingor decreasing the number ofpump strokes, as indicated on the instructionsheet.Precision Piston PumpTwo critical factors affecting the accuracyof detector tube measurementsare the flow rate and the volume of airdrawn through the tube by the pump.If the flow rate or volume varies, thesample will not be accurate.With a precision piston pump, air flowis initiated by the pump vacuum,which stays constant after continueduse.The vacuum is not spring-assisted aswith “squeeze-type” pumps. The suctionof squeeze-type pumps is determinedalmost exclusively by the forceof springs within the pump. Over timethe springs can lose tension, resultingin slow strokes, thus jeopardizing accuracyand repeatability.Deluxe Hazmat III Kit PNº 7013627Durable ConstructionOur unique pump design offers thebest of both worlds. It is simple to useand rugged enough for any industrialsetting. The light weight aluminum alloyconstruction provides years oftrouble free use.Standard Tube-Tip BreakerA tube-tip breaker, which catches theglass ends of the detector tube, is standardin each pump for added safety.Flying glass and misplaced brokentube tips are not a problem with theSensidyne pump.No Special ToolsNontechnical personnel can performnormal sampling and maintenancerapidly and accurately. You do nothave to purchase any special tools,and the spare items in the pump kitare normally all that are required foryears of trouble-free operation.Sensitive and Stable Absorbing MediaUsing our unique absorbing media, thetubes have extremely clear lines of demarcationof the color stain. No filterpaper or cumbersome reagents are required.This enhances reliability, reducesmeasurement time and increasesaccuracy. These are stable compounds,providing a long shelf life for mosttubes, thus reducing inventory costs.


Kits & AccessoriesHazardous Material Detection KitThe Sensidyne Hazmat III Kit is a portablehazardous material detection kitthat is lightweight, rugged, and capableof on-the-spot detection of numerousairborne contaminants. The kit utilizesa unique two-step approach for rapididentification of airborne contaminants.The short test uses two unique multistagequalitative tubes and a specialcolor chart to determine no fewer than70 compounds in as little as 2–3 minutes.The kit requires no electrical poweror user calibration and comes with ahard-shell, corrosion-resistant polyethylenecase.PNº 7013627Deluxe Hazmat Kit IIISoil Sampling KitField screening for contaminated soil isfast and easy using the Sensidyne SoilSampling Kit. A hand operated boringtool is used to make a three foot deephole in the soil just large enough to accepta special sampling probe with adetector tube inserted. A direct readingvapor zone sample is then made usingthe hand pump and any one of numerousdetector tubes.PNº 7013373Proudly distributed by:Soil Sampling KitIon TubesSensidyne Ion Detector Tubes providefast, inexpensive, quantitative field determinationof contaminants in wastewater.The tubes operate on the principleof capillary action or by drawingwater into the tube using a rubber bulb.Simply break off the tube ends and immersethe tube vertically into a beakerof sample water. A color stain forms fora quantitative measurement. Ion tubesare direct-reading with a printed scaleon each tube.One-Hand AdapterThe new one-hand adapter for theSensidyne Model AP-1S Pump is idealfor one hand sampling from a ladder orinto hard-to-reach places. With theadapter installed and a tube inserted, thepump handle can be drawn and lockedwithout actually taking a sample. Thepump can then be extended into thesampling area and activated with onehand.PNº 7013600One-Hand AdapterLong Duration (TWA) TubesDirect reading TWA tubes are used inconjunction with Gilian pumps to providea Time-Weighted Average readingover an eight hour work shift.Extension HoseAn extension hose of either 5 meters or10 meters in length is available for usein confined space entry, as well as a rigidtelescoping extension probe with up to10 working feet of length. The designof the tube holder at the free end of thehose permits a gas-tight fitting. Since thedetector tube is located at the samplingend of the hose, there is no need to allowfor the volume of air in the hoseline.PNº 7013596PNº 7013597PNº 70135985 m Hose10 m Hose10’ Telescoping ProbeHot ProbeThe Hot Probe allows sampling of gasesat elevated temperatures for applicationssuch as auto exhaust or stack emissionstesting. The Hot Probe rapidly cools thegas before it enters the detector tube.PNº 7013602Hot ProbeCompressed Breathing Air Analysis KitThe Sensidyne Compressed BreathingAir (CBA) Analysis Kit allows anyone tosimply, quickly, and quantitatively measurethe quality of their compressedbreathing air. Easy to use, the CBA Kit isan accurate and precise method for detectingcarbon monoxide, carbon dioxide,oil mist, oxygen, and water vapor(specific tubes not included). The CBAKit measures all four of the common contaminantsin breathing air, plus oxygendeficiency. With the CBA Kit, the measurementis quick and simple and doesn’trequire user calibration.PNº 7015406CBA Analysis KitTube Tip Breaker/CutterThe Tube Tip Breaker/Cutter (PNº7013601) is a convenient container forcutting and breaking detector tubes.“The Standard for Professionals” Sensidyne manufacturers, supplies, and services gas detection and air sampling pumpsthat are characterized by their ease of use, durability, accuracy, and economical cost.16333 Bay Vista Drive • Clearwater, Florida 33760 USA800-451-9444 • 727-530-3602• 727-539-0550 [fax] • www.sensidyne.com© 2000 Sensidyne, Inc. All rights reserved. H&S 3390 Rev B 0006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!