The world is changing butour power is constant...... <strong>Su</strong>-<strong>Kam</strong> Online UPS<strong>Su</strong>-<strong>Kam</strong> Power Systems Ltd.Corporate Office: Plot No. 54, Udyog Vihar Phase VI, Sector-37,Gurgaon-122001, Haryana, India.Tel.:+91-124-4030700,4170500,Fax:+91-124-4038700/1/2.E-mail: info@su-kam.com Website: www.su-kam.comw w w . s u - k a m . c o m


What is “Online”in an Online UPS?In the case of a regular inverter, the load (appliances andelectronic device like computers, air conditioners, etc.) isdirectly connected to the mains. The power backupcomes into play only when the mains go off.How can Online UPSact as a StabilizerAn Online UPS not only provides constant power backup, but italso works to improve your power supply. When the mains areon, it converts the AC (Alternate Current) into DC (DirectCurrent) and then reconverts it to AC. This removes thefluctuations and other disturbances present in the mainscurrent, and protects your load. You can say it acts as astabilizer for your load. This process is called ‘Double PowerConversion’.In the case of an Online UPS, the load is connected to themains through the UPS. Therefore the UPS is “Online”and the current always passes through the UPS itself.Security Check for your Current!Double Conversion is like a security X-ray machine installed atan airport. The luggage going in through the entry is like mainsAC. It is converted to DC and corrected for fluctuations anddisturbances, just like the X-ray machine scans for suspiciousitems in the luggage. The output belt is like the pure AC currentwhich is then transferred to the load.ONLINE UPS


How quick is an Online UPS?Your Online UPS takes next to no time in switching on! Because the UPShome, power disturbances may damageis already online, the switchover time from mains to UPS in case of ahigh-end electronic equipment like homeWhere’s my cash?Have you ever experienced the“cashless” problem at the ATMs.You may have put in your PIN anddesired amount, but the ATMtransaction is cancelled. Even amillisecond of delay in power backupcan cause such problems. With anOnline UPS installed at ATMs,this problem can be easily solved!power cut is zero.Zero Switchover Time makes the <strong>Su</strong>-<strong>Kam</strong> Online UPS the first choicewhen it comes to mission critical devices, where even a fraction of asecond matters. For example, in a hospital, where sensitive medicalequipment must always runs at specified voltages and power. Even attheatre systems LCD/Plasma TV etc. Anybreak in supply or fluctuation can causeproblems. Therefore, an Online UPS isabsolutely critical, which ensures no break inpower even in the case of a power cut.````ATM``


HOW CAN YOU KEEP AN EYE ONHow does an Online UPSprotect the load?your Online UPS?<strong>Su</strong>-<strong>Kam</strong> offers you what no other Online UPS can. With <strong>Su</strong>-<strong>Kam</strong> UPS systems, youcan actually control and monitor the UPS performance. This can be done through thePower Doc UPS monitoring system, which is a unique innovation by <strong>Su</strong>-<strong>Kam</strong>.Your Online UPS not only provides you power backup when you need it, but it alsoprotects the load from disturbances or fluctuations. It does this by a process calledGalvanic Isolation.This ensures maximum safety for high-risk applications like satellite systems, airtraffic control systems, internet nodes, bank transactions, etc. It also protects yoursystem from valuable data loss, interruption, errors, crashes or shutdowns.This means that there is a complete physical separation between the Input andOutput. This is important, because any disturbance in the mains supply is notallowed to pass through the separation and travel to the load. In an industrialenvironment, the level of power distortions can be very high. Also, even at home,sometimes heavy electrical work in neighbouring areas like welding work etc. candisturb the power supply. Galvanic Isolation ensures maximum security for the loadin such circumstances. In fact, with Galvanic Isolation, the Output can be grounded,in accordance with to international and local standards.Input CurrentQ. How does the Power Doc work?The Power Doc works with the help of a simple software installed in your PC called the Power Manager.This software acts as a transmitter that keeps you constantly updated about your UPS system.1. The Power Manager constantly updates information regarding the output voltages, batteryvoltages and other important parameters.2. The software keeps a log of important data like input and output voltage, input and outputGalvanic IsolationGalvanic Isolation -The Water Filter Effectfrequency, battery voltage, etc. so that the user can check the UPS performance at any time. Thiscan also help predict any future problems.3. The user can shut down the system automatically without individually switching off each PC. Infact the user can also prioritise the shutdown procedure allowing for a sequential shutdown ofvarious system components, thereby protecting critical data and also unsaved files.4. The software uses the standard TCP/IP communication protocol and supports all operatingsystems including Windows.Output Current


1 Phase ONLINE UPSMonitoring softwareSoftware FunctionsGraphical Monitoring of the UPS status: An easy to use powerful tool that allowsmonitoring and controlling the UPS systems. Input Voltage, Input Frequency,Output Voltage, Output Frequency, Battery Status, Load Status and Overload Statuscan be automatically monitored by it. There are graphical versions for both Windowsand Linux.Detailed Display of all the UPS Data: Provides on screen, all the data required tomake an accurate and speedy diagnosis of the UPS operation.Alarm Notification via e-mail and SMS: Can be configured to automatically notify analarm via an e-mail or SMS message. In case of any critical error, it pops up themessage on screen.Can youmonitoryour OnlineUPS longdistance?3 Phase ONLINE UPSMonitoring softwareProgramming the UPS Commands: The commands normally carried out by theusers are programmed so that these are performed automatically e.g. shuttingdown and switching the server back on, UPS battery test, etc.Remote Monitor your UPS!You can also remote monitor your <strong>Su</strong>-<strong>Kam</strong>Online UPS! In fact you can monitor a largenumber of systems spread out over a largearea right from your office desktop. Toknow more, read on.If you have several UPS systems spreadout over a large geographical area, itbecomes difficult to monitor all of themsimultaneously. Therefore <strong>Su</strong>-<strong>Kam</strong> offersyou the unique Ethernet Based UPSMonitoring Software. Operating throughyour Local Area Network (LAN), you canmonitor all your systems through a singlewindow.The software generates an automatice-mail in case of any alert, providing youthe contact person and contact details atthe site of installation, so that problemscan be immediately rectified.


Ethernet Based UPSMonitoring SoftwareCan your UPS“bypass”the mains voltage?The <strong>Su</strong>-<strong>Kam</strong> Online UPS comes equipped with a Bypass feature, whichallows the load to run on main supply, when the UPS is undermaintenance or service upgradation. Thus it ensure uninterruptedpower supply for the load.How does my <strong>Su</strong>-<strong>Kam</strong>UPS have extrastamina?The <strong>Su</strong>-kam UPS is like a long distance runner. It has a HeavyDuty Charger that allows for faster charging. The faster thebattery can be charged, the bigger the battery you can use.Therefore, the UPS can deliver sustained power for longerperiods of time. It is like a long distance runner who utilizesminimum energy to deliver maximum performance.ROAD MAINTENANCE? USE THE FLYOVER!If you considerthe UPS to be acity road, thenthe BypassSwitch is like aflyover whichpasses the mainscurrent directlyto the loadthrough flyoverundermaintenance orserviceupgradation.How do I choosemy <strong>Su</strong>-<strong>Kam</strong> UPS?<strong>Su</strong>-<strong>Kam</strong> Online UPS systems comes in two ranges, namely the IntelliQ and the Sinclair-ISeries. The IntelliQ Series operates at lower frequencies and the Sinclair-I Series worksat higher frequencies. In fact, the IntelliQ Series comes in three different phaseoptions:1 phase in – 1 phase out3 phase in – 1 phase out3 phase in – 3 phase out


IntelliQ1 phase in – 1 phase outSalient Features:- DSP based PWM technology using IGBT- Double Conversion VFI technology- True Galvanic Isolation- Overload handling capacity up to 300% for 1 sec.- LCD Panel for Input/Output Voltage, Input/Output Frequency, Power & CurrentBattery Voltage, Mains Fail, UPS on Battery, Inverter ON/OFF, Battery Low/High,Output Low/High Voltage, Overload/Short Circuit etc.- User settable Output Voltage (220/230/240V)- RS-232 Interface software for advanced Power Manager- Fixed settable heavy duty charger for long backup- Generator compatibleRange: 1KVA – 10KVAI/P VOLT: 201.5VI/P FREQ:48.0HztO/P PWR: 3775VAO/P FREQ:50.0HzO/P VOLT: 230.15VO/P CRNT: 23.4AtSELF TEST INPROGRESS ...LCD DISPLAY MESSAGES* ATTENTION *OVERLOAD >150%SYSTEM CAPACITY10KVA-192VD.C VOLT : 204.1VINVERTER ONt* PROTECTION *BATTERY LOWt1 Phase Input - 1 Phase OutputTECHNICAL SPECIFICATIONSType1 Phase Input - 1 Phase OutputSeriesIntelliQ Online UPSTechnologyDSP based Double Conversion Online UPS system with true galvanic isolationRatingsModelCapacity1 KVAIQ111K1 KVA2 KVAIQ112K2 KVA3 KVAIQ113K3 KVA5 KVAIQ115K5 KVA7.5 KVAIQ117.5K7.5 KVA10 KVAIQ1110K10 KVAINPUTNo. of Phases1Phase-3Wire P,N,EVoltage Range170 V - 280 Volts ACInput Frequency Range47 to 53Hz.OUTPUTPower 700 W 1600 W 2400 W 4000 W 6000 W 8000 WLoad PF Range0.8 laggingPhase1 Phase -2 Wire (P,N)Output WaveformPure Sine WaveVoltage 230 V +/-1%Frequency 50Hz +/-0.1%Load Crest Factor > 3:1Output Voltage THD 85%Operating Temperature0-45DegCOperating Humidity95% CondensingMonitoring SoftwareAdditional Software available for remote monitoringAccoustic Noise


IntelliQ3 phase in – 1 phase outSalient Features:- DSP based PWM technology using IGBT- Double Conversion VFI technology- True Galvanic Isolation- UPS Auto Self Test on L CD Panel- User settable Output Voltage (220/230/240V)- Static Bypass Switch (optional)- Hot Standby (optional)- RS-232 Interface software for advanced Power Manager- Works on any input phase sequence- Field settable heavy duty charger for long backupRange: 10KVA – 25KVADSP ONLINE UPSIntelliQ SeriesAUTO MODE* PROTECTION *BATTERY LOWSU-KAMWELCOMES YOUO/P VOLT: 230.15VO/P CRNT: 35A* PROTECTION *OUTPUT SHORT CKTLCD DISPLAY MESSAGESPROTECTION MESSAGESO/P PWR: 24775VAO/P FREQ:50.0HzSYSTEM CAPACITY10KVA-360V DC* PROTECTION *BATTERY HIGHSELF TEST: PASSDC VOLT:406.OVINVERTER ON* PROTECTION *OVERLOAD SHUTDOWN3 Phase Input - 1 Phase OutputTECHNICAL SPECIFICATIONSType3 Phase Input – 1 Phase OutputSeriesIntelliQ Online UPSTechnologyDSP based Double Conversion Online UPS with true Galvanic IsolationRatings 7.5 KVA10 KVA 15 KVA 20 KVA 25 KVAModel IQ317.5KIQ3110K IQ3115K IQ3120K IQ3125KCapacity 7.5 KVA10 KVA 15 KVA 20 KVA 25 KVAINPUTNo. of Phases3 Phase- 4 WireVoltage Range310 V – 480 Volt ACInput Frequency Range45 - 55 HzOUTPUTPower 6000 W8000 W 12000 W 16000W 20000 WLoad PF Range0.8 laggingPhase1 Phase -2 Wire (P,N)Output WaveformPure Sine WaveVoltage 230V ± 1%Frequency 50Hz +/-0.1%Load Crest Factor > 3 :1Output Voltage THD 90%Operating Temperature0-45DegCOperating Humidity95% CondensingMonitoring SoftwareAdditional Software available for remote monitoringAccoustic Noise 110%* ATTENTION *OVERLOAD >150%


IntelliQ3 phase in – 3 phase outSalient Features:- DSP based PWM technology using IGBT- Double Conversion VFI technology- True Galvanic Isolation- Works on any phase sequence without coming in Battery Mode- LCD Panel for Input/Output Voltage, Input/Output Frequency and Output Powerfor all 3 phases simultaneously (very useful for monitoring)- User settable Output Voltage (380/400/415V)- RS-232 Interface software- Remote monitoring analysis & control using Powerdoc Software- Auto Self test on LCD Panel- 3-Phase Static Bypass Switch (optional)Range: 5KVA – 50KVA*<strong>Su</strong>-<strong>Kam</strong> Online UPS*R-O/P Freq: 49.99 HzY-O/P Freq: 50.04 HzB-O/P Freq: 50.04 Hz*<strong>Su</strong>-<strong>Kam</strong> Online UPS*R-O/P Volt:230.2 VY-O/P Freq:50.02 HzB-O/P Crnt:00.90 A*<strong>Su</strong>-<strong>Kam</strong> Online UPS*Y-O/P Volt:230.6 VY-O/P Freq:49.99 HzY-O/P Crnt:20.90 ALCD DISPLAY MESSAGES*<strong>Su</strong>-<strong>Kam</strong> Online UPS*R-O/P Volt:230.3 VY-O/P Volt:230.4 VB-O/P Volt:230.5 V*<strong>Su</strong>-<strong>Kam</strong> Online UPS*B-O/P Volt: 230.8 VB-O/P Freq: 50.04 HzB-O/P Crnt: 20.90 A*<strong>Su</strong>-<strong>Kam</strong> Online UPS*R-O/P Power:04180 VAR-O/P Power:04280 VAR-O/P Power:04090 VA3 Phase Input - 3 Phase OutputTECHNICAL SPECIFICATIONSType3 phase input - 3 phase outputSeriesIntelliQ Online UPSTechnologyDSP based Double Conversion Online UPS system with True Galvanic IsolationRatingsModelCapacity5 KVAIQ335K5 KVA7.5 KVAIQ337.5K7.55 KVA10 KVAIQ3310K10 KVA15 KVAIQ3315K15 KVA20 KVAIQ3320K20 KVA25 KVAIQ3325K25 KVA30 KVAIQ3330K30 KVA40 KVAIQ3340K40 KVA50 KVAIQ3350K50 KVAINPUTNo. of Phases3 Phase – 4 WireVoltage Range310 V – 480 Volt ACInput Frequency Range45 – 55 HzOUTPUTPower4000 W 6000 W 8000 W 12000 W 16000 W 20000 W 24000 W 32000 W 40000 WLoad PF Range0.8 laggingPhase3 Phase- 4 WireOutput WaveformPure Sine WaveVoltage400V ± 2% (P-P), 380V & 415V user selection also availableFrequency50Hz +/-0.1HzLoad Crest Factor > 3:1Output Voltage THD 90%Operating Temperature0-45DegCOperating Humidity95% CondensingMonitoring SoftwareAdditional Software available for remote monitoringAccoustic Noise


Sinclair-I1 phase in – 1 phase outSalient Features:- Microcontroller based High Frequency design using IGBT- Active Power Factor Correction with input power factor > 0.98 for 10% to 100% load- Reduced hardware for increased reliability- High efficiency in both Mains and Battery Modes- Extra wide Input Voltage window range minimizing battery usage and enhancing batteryutilization and life- Noiseless operation- SMPS Based Pure DC Charger with extended power, extended battery life and lowermaintenance cost- Inbuilt static bypass- High crest factor, handles all high-inrush current loads without need for power rating upgrade- Multiple protection features to ensure load safety- DC-start function- User friendly LCD display- Heavy duty charger for long backup- Parallel redundancy is available in 6 and 10KVA- SNMP monitoring (optional)Choice of Power:Sinclair-I UPS is available in two variants –a) With External Battery (1-10KVA) for more backupb) With Internal Battery (1-10KVA) for less backupTypeSeriesTechnologyMODELCapacityINPUT PARAMETERSNo. of PhasesVoltage RangeInput Power FactorInput Frequency RangeOUTPUT PARAMETERSPowerLoad PF RangePhaseOutput WaveformVoltageFrequencyLoad Crest FactorOutput Voltage THDLoading CapacityBY-PASSMaintenance By-PassBATTERIESNo of 12V BatteriesVoltageCharging CurrentGENERALIndicationAlarmProtectionCoolingUPS EfficiencyOperating TemperatureOperating HumidityMonitoring SoftwareAccoustic NoiseUPS Weight (With Batteries)Dimension (W x D x H)1 Phase Input - 1 Phase OutputTECHNICAL SPECIFICATIONS1 Phase Input - 1 Phase OutputSinclair-iHigh Frequency Online UPSSinclair-i1kVA IB 1kVA EB 2kVA IB 2kVA EB 3kVA IB 3kVA EB 6kVA IB 6kVA EB 10kVA IB 10kVA EB1Phase-3Wire (P,N,E)110- 300Volts ± 5Volt(Load dependant) 176 -276Volts ± 5Volt>0.97 at Full Load >0.98 at Full Load46 to 54Hz.700 W 1400 W 2100 W 4200 W 7000 W0.65 lagging to 1.01 Phase -3 Wire (P,N,E)Pure Sine Wave220/230/240VAC ± 2% ( selectable )Synchronization Range 46-54Hz, Slew Rate 1Hz/Sec, Battery Mode (50±0.2) Hz> 3:1150%: fault after 300ms, >130%: Transfer to bypass after 1s, shutdown afterauto recovery1 min.(Line mode)Static By-Pass3 8 8 20 2036VDC 96VDC 96VDC 240VDC 240VDC1A (8±1)A 1A (8±1)A 1A (8±1)A 2A (4.2±0.2)A 2A (4.2±0.2)ALCD panelMains Failure, Battery Low, Over Load & Short CircuitShort Circuit, Over Voltage & Under Voltage ProtectionForced Air Cooling85% 85% 85% 88% 88%0-45DegC95% CondensingAdditional Software available for remote monitoring


Static BypassSwitchThe Static Bypass Switch takes two sources of power at the input andmonitors them continuously to provide the best of the two availablepower source to the electrical load connected at the output. One sourceis used as the master and other as the slave. The load runs normally onthe master and in case of any deviation of voltage and frequency fromdefined thresholds the load is instantly transferred to the slave source toprovide uninterrupted supply to the load. It is based on solid-stateswitch's Silicon Controlled Rectifier (SCR) devices so it has no mechanicalmoving parts and thus requires minimal maintenance. It provides fast transfer time to protect the outputMonitoring Softwareload. The input sources can be a combination of UPS supply, mains supply or generator supply providingsinusoidal output. The Static Bypass Switch has high overload handling capability for safety. Typical applicationsinclude Servers, Data Centres, Call Centres, Operation Theatre or any other place which requires redundantpower supply with fast transfer time so that load connected at the output does not experience anypower break. <strong>Su</strong>-<strong>Kam</strong>'s Single phase and Three phase static bypass switch ensures high reliability and redundancyof power supply to the critical load.Single Phase Static Bypass Switch (SBS)• Micro-controller based design• 230 VAC, 50Hz input / output• Power: 1KVA - 5KVA, 6KVA - 10 KVA• Provides redundant power to load by two independent powersources• Operates with two UPS or non-UPS power sources (Grid or Generator)providing a sinusoidal output• Fast transfer time• High surge current capability• Compact and robust design• Hot swap function of input sources: Servicing of one of thesources can be done without interrupting the power flow to load• User friendly LED display• RS-232 Communication for monitoringThree Phase Static Bypass Switch (SBS)• Digital Signal Controller based design• 400 VAC, 50Hz input / output• Power: 5KVA - 10KVA, 11KVA - 25 KVA• Provides redundant power source for load• Operates with any UPS or power source that has a sine waveoutput• Fast transfer time• High surge current capability• Compact and robust design• Hot swap function of input sources: Servicing of one of thesources can be done without interrupting the power flow to load• User friendly LCD display• RS-232 Communication for monitoringDesignTECHNICAL SPECIFICATIONSMicrocontroller based designInput Voltage 230V (+15% -25%)Frequency 47 Hz to 53 HzOutput RatingEfficiency >98%Transfer/Retransfer TimeOverloadProtectionEnvironmental5KVA, 10KVAOperating Temperature 0 - 45°CRelative HumidityAudible NoiseIndicationsCommunicationHot swap function of input sourcesDesignSpecifications of Single Phase (1 phase with neutral) Static By-pass Switch (SBS)2 to 15 ms (depending on the input condition of sourcecondition - synchronized or unsynchronized)125% for 10 min, 150% for 1 min and 300% for 10 msec.Input under and over voltage, Output Short Circuit0 - 95% non-condensing< 45dB (A) at 1.5 metersAvailability of Source 1 & 2 by Graphical LED DisplayPower flow to load either by Source 1 or 2Output ON / OFFOverload / Short CircuitRS-232 Communication with PC for display and monitoringServicing of one of the sources can be done without interrupting thepower flow to load.Specifications of Three Phase (3 phase with neutral) Static By-pass Switch (SBS)Digital Signal Controller Based DesignInput Voltage 400V (+15% - 20%)Frequency 50 Hz ± 10%Output Rating10 KVA, 25 KVAEfficiency > 98%Transfer/Retransfer Time5 to 18 ms (depending on the input condition of source condition- synchronized or unsynchronized)OverloadProtectionEnvironmentalOperating Temperature 0 - 45°CRelative Humidity95% non-condensingAudible NoiseIndicationsCommunicationHot swap function of input sourcesTECHNICAL SPECIFICATIONS125% for 10 min, 150% for 1 min, 200% for 10 sec and 300% for 10 msecInput under and over voltage Output overload, Output Short Circuit< 45dB (A) at 1.5 metersLCDAvailability of Source PrioritySource 1 & Source 2 - Voltage & FrequancyOutput ON / OFFOverload / Short CircuitRS-232 Communication with PC for display and monitoringServicing of one of the sources can be done without interrupting the power flow toload


Where all can I use<strong>Su</strong>-<strong>Kam</strong> Online UPS?The <strong>Su</strong>-<strong>Kam</strong> Online UPS can be used for a variety of applications, where reliable powerbackup plays an important role. These include:Colour LabsEmbroidery MachinesOfficesSecurity Systems / Control RoomOffices, Workstation and Lan ServersMedical EquipmentPlottersPoint of Sale (POS) SystemsTelecommunication SystemATM MachinesAir Traffic Control SystemSatellite SystemPCs, Workstations, Computer Labs, IT Networks, Internet Nodes/Servers, Plotters, Monitors &Modems, Security Equipment, EPABX Systems, Fax Machines, Networking <strong>Product</strong>s, Point ofSale (POS) Systems, Cash Registers, ATM Machines, SOHO (Small Office Home Office), DataCentres/Offices, Industrial Equipment, Security Systems, Overhead Projector, Local AreaNetworks (LAN), Telecommunication Systems, Electrical Medical Equipment, BiomedicalEquipment, Satellite Systems, Industial Computer-based Machines, Studio Equipment, VideoEquipment, Sound Equipment, Printing & Media Equipment, Small Automation Control Equipment,Sensitive electronic or any other computerized systems, Access Control System, andmany more.