11.07.2015 Views

Product Catalogue - Su-Kam

Product Catalogue - Su-Kam

Product Catalogue - Su-Kam

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Static BypassSwitchThe Static Bypass Switch takes two sources of power at the input andmonitors them continuously to provide the best of the two availablepower source to the electrical load connected at the output. One sourceis used as the master and other as the slave. The load runs normally onthe master and in case of any deviation of voltage and frequency fromdefined thresholds the load is instantly transferred to the slave source toprovide uninterrupted supply to the load. It is based on solid-stateswitch's Silicon Controlled Rectifier (SCR) devices so it has no mechanicalmoving parts and thus requires minimal maintenance. It provides fast transfer time to protect the outputMonitoring Softwareload. The input sources can be a combination of UPS supply, mains supply or generator supply providingsinusoidal output. The Static Bypass Switch has high overload handling capability for safety. Typical applicationsinclude Servers, Data Centres, Call Centres, Operation Theatre or any other place which requires redundantpower supply with fast transfer time so that load connected at the output does not experience anypower break. <strong>Su</strong>-<strong>Kam</strong>'s Single phase and Three phase static bypass switch ensures high reliability and redundancyof power supply to the critical load.Single Phase Static Bypass Switch (SBS)• Micro-controller based design• 230 VAC, 50Hz input / output• Power: 1KVA - 5KVA, 6KVA - 10 KVA• Provides redundant power to load by two independent powersources• Operates with two UPS or non-UPS power sources (Grid or Generator)providing a sinusoidal output• Fast transfer time• High surge current capability• Compact and robust design• Hot swap function of input sources: Servicing of one of thesources can be done without interrupting the power flow to load• User friendly LED display• RS-232 Communication for monitoringThree Phase Static Bypass Switch (SBS)• Digital Signal Controller based design• 400 VAC, 50Hz input / output• Power: 5KVA - 10KVA, 11KVA - 25 KVA• Provides redundant power source for load• Operates with any UPS or power source that has a sine waveoutput• Fast transfer time• High surge current capability• Compact and robust design• Hot swap function of input sources: Servicing of one of thesources can be done without interrupting the power flow to load• User friendly LCD display• RS-232 Communication for monitoringDesignTECHNICAL SPECIFICATIONSMicrocontroller based designInput Voltage 230V (+15% -25%)Frequency 47 Hz to 53 HzOutput RatingEfficiency >98%Transfer/Retransfer TimeOverloadProtectionEnvironmental5KVA, 10KVAOperating Temperature 0 - 45°CRelative HumidityAudible NoiseIndicationsCommunicationHot swap function of input sourcesDesignSpecifications of Single Phase (1 phase with neutral) Static By-pass Switch (SBS)2 to 15 ms (depending on the input condition of sourcecondition - synchronized or unsynchronized)125% for 10 min, 150% for 1 min and 300% for 10 msec.Input under and over voltage, Output Short Circuit0 - 95% non-condensing< 45dB (A) at 1.5 metersAvailability of Source 1 & 2 by Graphical LED DisplayPower flow to load either by Source 1 or 2Output ON / OFFOverload / Short CircuitRS-232 Communication with PC for display and monitoringServicing of one of the sources can be done without interrupting thepower flow to load.Specifications of Three Phase (3 phase with neutral) Static By-pass Switch (SBS)Digital Signal Controller Based DesignInput Voltage 400V (+15% - 20%)Frequency 50 Hz ± 10%Output Rating10 KVA, 25 KVAEfficiency > 98%Transfer/Retransfer Time5 to 18 ms (depending on the input condition of source condition- synchronized or unsynchronized)OverloadProtectionEnvironmentalOperating Temperature 0 - 45°CRelative Humidity95% non-condensingAudible NoiseIndicationsCommunicationHot swap function of input sourcesTECHNICAL SPECIFICATIONS125% for 10 min, 150% for 1 min, 200% for 10 sec and 300% for 10 msecInput under and over voltage Output overload, Output Short Circuit< 45dB (A) at 1.5 metersLCDAvailability of Source PrioritySource 1 & Source 2 - Voltage & FrequancyOutput ON / OFFOverload / Short CircuitRS-232 Communication with PC for display and monitoringServicing of one of the sources can be done without interrupting the power flow toload

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!