11.07.2015 Views

Fuji Professional Dataguide - Silverprint

Fuji Professional Dataguide - Silverprint

Fuji Professional Dataguide - Silverprint

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FUJIFILMPROFESSIONAL DATA GUIDEFUJICHROME Sensia 400 [RH]ISO 400/27°, Daylight TypeFUJICOLOR PORTRAIT FILM NPS 160 PROFESSIONAL [NPS]ISO 160/23°, Daylight Type● SPECTRAL SENSITIVITY CURVESSensitivity* (log)2.01.00.0-1.0BlueSensitiveLayerGreenSensitiveLayerRedSensitiveLayer400 500 600 700Wavelength (nm)● SPECTRAL DYE DENSITY CURVESSpectral Diffuse Density1.51.00.50.0Yellow Magenta Cyan400 500 600 700Wavelength (nm)● SPECTRAL SENSITIVITY CURVESRelative Sensitivity* (log)1.0BlueSensitiveLayerGreenSensitiveLayerRedSensitiveLayerCyanSensitiveLayer400 500 600 700Wavelength (nm)● SPECTRAL DYE DENSITY CURVESSpectral Diffuse Density3.02.01.00.0Mid-scale DensityMinimum Density400 500 600 700Wavelength (nm)Process : CR-56/E-6Densitometry : Status ADensity : 1.0 above minimum density*Sensitivity equals the reciprocal of the exposure(J/cm 2 ) required to produce a specified densityExposure:Process :Separated LightCR-56/E-6Process : CN-16Densitometry : Status MDensity : 1.0 above minimum density*Sensitivity equals the reciprocal of the exposure(J/cm 2 ) required to produce a specified densityTypical densities for a mid-scale neutral subjectand for minimum density.● CHARACTERISTIC CURVES● CHARACTERISTIC CURVES4.03.53.0RedGreenBlue4.03.53.0Density2.52.01.51.00.50.0-4.0 -3.0 -2.0 -1.0 -0.0Exposure [log H (lux-seconds)]Exposure : Daylight,1/50 sec.Process : CR-56/E-6Densitometry : Status ADensity2.52.01.51.00.50.0BlueGreenRed-4.0 -3.0 -2.0 -1.0 0.0 1.0Exposure [log H (lux-seconds)]Exposure : Daylight,1/125 sec.Process : CN-16Densitometry : Status M● MTF CURVE● MTF CURVEResponse (%)1501007050302010751 5 10 20 50 100 200Spatial Frequency (cycles/mm)● DIFFUSE RMS GRANULARITYVALUE ........ 13Micro-densitometer Measurement Aperture:48µm in diameterSample Density:1.0● RESOLVING POWERChart Contrast 1.6:1 - 55 lines/mmChart Contrast 1000:1 - 135 lines/mmResponse (%)1501007050302010751 5 10 20 50 100 200Spatial Frequency (cycles/mm)● DIFFUSE RMS GRANULARITYVALUE ........ 4Micro-densitometer Measurement Aperture:48µm in diameterMagnification: 12 ×Sample Density:1.0 above minimum density● RESOLVING POWERChart Contrast 1.6:1 - 63 lines/mmChart Contrast 1000:1 - 125 lines/mmExposure: DaylightProcess : CR-56/E-6Exposure: DaylightProcess : CN-165 4 5 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!