Administrative OfficePO Box 730, 100 West MainSackets Harbor, NY 13685Phone: (315) 646-2234Fax: (315) 646-2297E-mail: staff@amscert.com<strong>Desiccant</strong> <strong>Quantity</strong> <strong>Review</strong> <strong>of</strong> <strong>Changes</strong> (<strong>ACPF</strong>)(CN IG 0112)Overview:A number <strong>of</strong> concerns had been raised regarding IGCC®/IGMA® desiccant guidelines. This prompted acomprehensive review resulting in approval <strong>of</strong> new guidelines at the January 31 st , 2012 meeting. This wasfurther reviewed at the October 31, 2012 meeting as below:10.31.12.4 A) <strong>Desiccant</strong> <strong>Quantity</strong> – IGCC/IGMA adopted the Adsorption Capacity per Perimeter Foot(<strong>ACPF</strong>) rating and related guidelines at the January 2012 meeting to address desiccant quantityand changes in desiccant. An implementation date <strong>of</strong> 1/1/13 was established. It was noted thatsome suppliers have been slow to provide the specification values needed to determine <strong>ACPF</strong>,while others have questions the parameters (temperature and humidity) used to establish thedesiccant suppliers specification values. After discussion it was agreed to continue with thecurrent requirements and enforcement <strong>of</strong> the <strong>ACPF</strong> rating 1/1/13. IGCC/IGMA shall maintain alist <strong>of</strong> desiccants and suppliers who have provided a specification, but IGCC/IGMA will notpresent the actual specification values.IGCC/IGMA <strong>Desiccant</strong> Guideline <strong>Changes</strong>G.26 For all Certified Products and prototypes for Certification testing, the fabricator shall have on file acopy <strong>of</strong> the <strong>Desiccant</strong> supplier’s specification showing the minimum equilibrium water adsorption capacity(weight %) as measured at 25 o C (77 o F) and 50 % Relative Humidity (+/- 5%). Additionally the fabricatorshall document the weight <strong>of</strong> desiccant or desiccant system (grams) in the certified product or prototype.From this data, the fabricator shall document the adsorption capacity per perimeter foot (<strong>ACPF</strong>) using thefollowing formula: (Modified 1/31/12)ALWAYS<strong>ACPF</strong> (grams/ ft.) = Weight <strong>of</strong> <strong>Desiccant</strong> Product (g) x Adsorption Capacity (wt %)Perimeter (Feet) x 100Note: For all 14 x 20 inch test specimens the perimeter is 5.66 feetA.DE.1 A manufacturer may use the same IGCC®/IGMA® number on production units having air spacethicknesses equal to, or greater than the model tested provided the desiccant Adsorption Capacity perPerimeter Foot (<strong>ACPF</strong>) remains the same (- 10%) or is greater. A manufacturer may use the sameIGCC®/IGMA® number on production units having an air space thickness smaller than the model testedprovided the manufacturer maintains the same or more sides filled with desiccant. (Modified 1/31/12)Certification Notes (CN IG0112)Page 1 <strong>of</strong> 2Initial Publish Date: 01/31/12Approval Date: 10/31/12Revision Date: 12/10/12
A.DE.2 A change in supplier <strong>of</strong> the same generic type <strong>of</strong> desiccant from that tested will not require adifferent IGCC®/IGMA® number. However, Guideline A.SS.2 shall apply where applicable. (Modified1/31/12)A.DE.3 The use <strong>of</strong> the same loose fill desiccant manufactured in different particle size ranges will not requirea different IGCC®/IGMA® number. (Modified 1/31/12)NEVERN.DE.1 A change in generic type <strong>of</strong> desiccant will require a different IGCC®/IGMA® number. For purpose<strong>of</strong> desiccant guidelines, the generic types <strong>of</strong> desiccant are 1) LF = Loose Fill desiccant, 2) IB = Imbeddeddesiccant system, 3) MX = <strong>Desiccant</strong> Matrix. (Modified 1/31/12)Example <strong>of</strong> <strong>ACPF</strong> CalculationProduct TypeWeight <strong>of</strong><strong>Desiccant</strong>Product (grams)XAdsorptionCapacity (Wt%)÷ Spacer Perimeter(feet) X 100(5.66X100) = 566= <strong>ACPF</strong>Stainless Steel Box Spacer(LF <strong>Desiccant</strong>)39(<strong>Desiccant</strong> Only)X 14.0(Supplierminimumspecification)÷ 566 (based onstandard 14 X 20unit)= 0.96Certification Notes (CN IG0112)Page 2 <strong>of</strong> 2Initial Publish Date: 01/31/12Approval Date: 10/31/12Revision Date: 12/10/12