11.07.2015 Views

HUBBELL Surge Protective Devices (SPD) - Hubbell Wiring Device ...

HUBBELL Surge Protective Devices (SPD) - Hubbell Wiring Device ...

HUBBELL Surge Protective Devices (SPD) - Hubbell Wiring Device ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SpikeShield Power Quality <strong>Surge</strong> <strong>Protective</strong> <strong><strong>Device</strong>s</strong> (<strong>SPD</strong>)Wired-In Branch Panel Protection, <strong>Surge</strong> Arrestorsand <strong>Surge</strong> <strong>Protective</strong> <strong><strong>Device</strong>s</strong>Wired-In Branch Panel Protection• 100,000 Peak Amperage Capacity• Ideal for areas where space is a major consideration• Can be mounted directly to the panel through a chasenipple connection to reduce lead length and impedance• NEMA 4X housing• 200kA SCCR rating• UL 1449-3rd editionWired-In <strong>Surge</strong> Arrestors and <strong>Surge</strong> <strong>Protective</strong> <strong><strong>Device</strong>s</strong>• 36,000, 40,000, 50,000 and 120,000Peak Amperage Capacity• <strong>Surge</strong> arrestors are a low cost solution that may beinstalled on the line side or load side of the serviceentrance• Excellent for OEM applications where size is animportant variable• Single phase wired-in surge protective devices featurea compact design• NEMA 4X Rated• UL 1449-3rd editionWired-In Branch Panel Protection 100,000 Peak Amp Capacity (Type 2 <strong>SPD</strong>)Service Voltage V AC Configuration Catalog Number120/240 Single Phase120/208 Wye*240 Delta240/120 Delta split phase277/480 Wye**480 Delta347/600 Wye600 Delta1Ph. 3-wire +G3Ph. Wye 4-wire +G3Ph. Delta 3-wire Corner Gnd3Ph. Delta 4-wire +G ‘High Leg’3Ph. Wye 4-wire +G3Ph. Delta 3-wire Corner Gnd3Ph. Wye 4-wire +G3Ph. Delta 3-wire Corner GndNote: *120/208 Wye also applies to 127/220 Wye.**277/480 Wye also applies to 220/380 Wye, 230/400 Wye and 240/415 Wye.HBL3W100CHBL4W100CHBL5W100CHBL6W100CHBL8W100CHBL9W100CHBL10W100CHBL11W100CHBL9W100CHBLSDSA40Wired-In <strong>Surge</strong> Arrestors, Single Phase 36,000 and Three Phase 40,000(Type 1 / Type 2 <strong>SPD</strong>)Service Voltage V AC Configuration Peak Amp Capacity Mounting Means Catalog Number120/240 Single Phase600V Max Three Phase1Ph. 3-wire3Ph. 3-wire36kA40kABack Nipple MountBack Nipple MountHBLSDSA36HBLSDSA40HBLSDSA36Wired-In <strong>Surge</strong> <strong>Protective</strong> <strong><strong>Device</strong>s</strong> 50,000 and 120,000 Peak Amp Capacity(Type 1/Type 2 <strong>SPD</strong>)Service Voltage V AC Configuration Peak Amp Capacity Mounting Means Catalog Number120/240 Single Phase120/240 Single Phase1Ph. 3-wire + G1Ph. 3-wire + G50kA120kASide Nipple MountSide Nipple MountHBL3W50HBL3W120HBL3W50<strong>Wiring</strong> <strong>Device</strong>-Kellems5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!