7.3 BASE METAL EXTENSION WIRES AND COMPENSATINGCABLES TYPES AND TOLERANCESThermocouple. Wire Types and CodesThermocouple Conductors ± CableTypeCodeE Nickel Chromium / Constantan (Nickel EXChromium / Copper-Nickel, Chrome /Constantan, T1 / Advance, Ni Cr /Constantan)J Iron* / Constantan Iron / Copper-Nickel, Fe / JXKonst, Iron /Advance, Fe /Constantan, I/C)K Nickel Chromium / Nickel Aluminium* KX(NC/NA, Chromel / Alumel, C/A, T1/T2 NiCr / Ni, Ni Cr / Ni Al)N Nicrosil / Nisil NXNCT Copper / Constantan (Copper / Copper-Nickel, TXCu / Con, Copper / Advance)Vx Copper / Constantan (Low Nickel) Cu / KCBConstantan) Compensating for “K”(Cu / Constantan)U Copper /Copper Nickel, Compensating For RCAPlatinum 10% or 13% Rhodium / Platinum SCA(Codes S and R respectively) Copper /Cupronic, Cu / Cu Ni, Copper / No. 11 Alloy)• Magnetic () Alternative & Trade NamesIdentification as to whether a thermocouple cable type is extension orcompensating is indicated in the example which follows; however, please notethat a letter A or B after the C for Compensating refers to the CableTemperature Range in accordance with the table of Tolerance Values set out inthis standard.K X 1 = K EXTENSION CLASS 1K CA 2 = K COMPENSATION CLASS 2 0 to 150° 7.4 THERMOCOUPLE WIRE TOLERANCESThe figure shown in the tables are those appropriate to the measuring junction<strong>temperature</strong> in the final column. In most cases the error expressed in degreesTEMPSENSINSTRUMENTS57


celcius will be larger at lower thermocouple junction <strong>temperature</strong>s.Cable Tolerance Class Cable Temp. Measuring JunctionRange<strong>temperature</strong>JX ±85µV (±1.5°C) ±140µV (±2.5°C) -25°C to 200°C 500°CTX ±30µV (±0.5°C) ±60µV (±1.0°C) -25°C to +100°C 300°CEX ±120µV (±1.5°C) ±200µV (±2.5°C) -25°C to +200°C 500°CKX ±60µV (±1.5°C) ±100µV (±2.5°C) -25°C to +200°C 900NX ±60µV (±1.5°C) ±100µV (±2.5°C) -25°C to +200°C 900KCA -- ±100µV (±2.5°C) 0°C to +150°C 900KCB -- ±100µV (±2.5°C) 0°C to +100°C 900NC -- ±100µV (±2.5°C) 0°C to +150°C 900RCA -- ±30µV (±2.5°C) 0°C to +100°C 1000RCB -- ±60µV (±5.0°C) 0°C to +200°C 1000SCA -- ±30µV (±2.5°C) 0°C to +100°C 1000SCB -- ±60µV (±5.0°C) 0°C to +200°C 1000NOTE:1. Cable <strong>temperature</strong> range may be restricted to figure lower then thoseshown in the table because of <strong>temperature</strong> limitation imposed by theinsulant.2. A cable comprising two copper conductors may be used with type Bthermocouple. The expected maximum additional deviation within thecable <strong>temperature</strong> range 0°C to 100°C is 40 µV. the equivalent in<strong>temperature</strong> is 3.5°C when the measuring junction of the thermocouple isat 1400°C.TEMPSENSINSTRUMENTS58

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!