<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERT5T8TC-DELTC-SELTC-TELTC-LTC-DD<strong>EM</strong> <strong>BASIC</strong>, <strong>230</strong> – <strong>240</strong> V <strong>50</strong>/<strong>60</strong> Hz<strong>BASIC</strong> versionProduct description• <strong>Emergency</strong> <strong>lighting</strong> supply unit for manual testing• For linear and compact fluorescent lamps• Small dimensions (28 x 39 mm cross-section)Properties• 1or 3 h rated duration• Compatible with all electronic ballasts(dimmable and non-dimmable)• Can also be used in combination with conventional magneticballasts• 5-pole technology: 4-pole lamp changeover and delayed powerswitching for the ballast• Optimised AC output voltage for TC-DD and TC-L lamps• Optimised DC output voltage for T8 lamps• Cathode heating adapted for compact lamps• Switchover relay with high-current contacts• IDC (insulation displacement connection)• Green charge status display LED• Checking the emergency <strong>lighting</strong> function by interrupting theunswitched phase• Optional test switch• Deep discharge protection• Battery connection, short-circuit protected (not reversible)• Polarity reversal protection for battery (not reversible)Batteries• High-temperature cells• NiCd batteries• D or Cs cells• Blade terminals for simple connectionÈStandards, page 13Wiring diagrams and installation examples, page 14Technical dataRated supply voltage<strong>230</strong> – <strong>240</strong> VMains frequency<strong>50</strong> / <strong>60</strong> HzMains current0.04 ARated power7 WBattery charging time24 hDischarge current see page 11 / 12Charge current Cs cells120 mACharge current D cells210 mALeakage current (PE)0.5 mAAmbient temperature ta 0 ... +<strong>50</strong> °CMax. casing temperature tc 75 °CMains voltage changeover threshold according to EN <strong>60</strong>598-2-22Min. lamp starting temperature (emergency mode) 0 °CType of protectionIP20Ordering dataType1Article numberNumberof cellsPackaging,cartonPackaging,palletWeight perpc.Rated operating time 3 h<strong>EM</strong> 33A <strong>BASIC</strong> 89818556 3 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 33B <strong>BASIC</strong> 89818655 3 25 pc(s). 7<strong>50</strong> pc(s). 0.311 kg<strong>EM</strong> 33C <strong>BASIC</strong> 89800000 3 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 34A <strong>BASIC</strong> 89818557 4 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 34B <strong>BASIC</strong> 89818662 4 25 pc(s). 7<strong>50</strong> pc(s). 0.324 kg<strong>EM</strong> 34C <strong>BASIC</strong> 89800107 4 25 pc(s). 7<strong>50</strong> pc(s). 0.310 kg<strong>EM</strong> 34D <strong>BASIC</strong> 89800175 4 25 pc(s). 7<strong>50</strong> pc(s). 0.318 kg<strong>EM</strong> 35A <strong>BASIC</strong> 89818581 5 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 35B <strong>BASIC</strong> 89818667 5 25 pc(s). 7<strong>50</strong> pc(s). 0.311 kg<strong>EM</strong> 35C <strong>BASIC</strong> 89800001 5 25 pc(s). 7<strong>50</strong> pc(s). 0.315 kg<strong>EM</strong> 35D <strong>BASIC</strong> 89899621 5 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg1 <strong>EM</strong> 34B <strong>BASIC</strong> also available in 110 V AC version.Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 1


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTEROrdering dataType1Article numberNumberof cellsPackaging,cartonPackaging,palletWeight perpc.<strong>EM</strong> 36A <strong>BASIC</strong> 89818654 6 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 36C <strong>BASIC</strong> 89800108 6 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 36C HO <strong>BASIC</strong> 89800109 6 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kgRated operating time 1 h<strong>EM</strong> 13B <strong>BASIC</strong> 89895971 3 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 13E <strong>BASIC</strong> 89899864 3 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 14B <strong>BASIC</strong> 89899611 4 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 14C <strong>BASIC</strong> 89800118 4 25 pc(s). 7<strong>50</strong> pc(s). 0.318 kg<strong>EM</strong> 16C <strong>BASIC</strong> 89800119 6 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg<strong>EM</strong> 16C HO <strong>BASIC</strong> 89800120 6 25 pc(s). 7<strong>50</strong> pc(s). 0.337 kg1 <strong>EM</strong> 34B <strong>BASIC</strong> also available in 110 V AC version.Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 2


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERACCESSO-RIESTest switch <strong>EM</strong>2Product description• For connection to the emergency <strong>lighting</strong> unit• For checking the device functionOrdering dataTypeArticle numberPackaging,bagPackaging,cartonWeight per pc.Test switch <strong>EM</strong> 2 89805277 25 pc(s). <strong>60</strong>0 pc(s). 0.011 kgACCESSO-RIESStatus indication green LEDProduct description• A green LED indicates that charging current is flowing into thebatteryOrdering dataTypeArticle numberPackaging,bagPackaging,cartonWeight per pc.LED <strong>EM</strong> green 89899<strong>60</strong>5 25 pc(s). 200 pc(s). 0.011 kgLED <strong>EM</strong> green, ultra high brightness 89899756 25 pc(s). 800 pc(s). 0.012 kgData sheet 01/15-783-9Subject to change without notice.www.tridonic.com 3


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERBallast Lumen Factor (BLF) in %<strong>EM</strong> <strong>BASIC</strong> for linear lamps, 1 h1 h 3 cells 4 cells 6 cellsType<strong>EM</strong> 13B<strong>BASIC</strong><strong>EM</strong> 13E<strong>BASIC</strong><strong>EM</strong> 14B<strong>BASIC</strong><strong>EM</strong> 14C<strong>BASIC</strong><strong>EM</strong> 16C<strong>BASIC</strong><strong>EM</strong> 16C HO<strong>BASIC</strong>Article no. 89895971 89899864 89899611 89800118 89800119 89800120Lamp type Wattage BLF in emergency <strong>lighting</strong> mode in % for rated operating timeT8 18 W 22.5 2536 W 15.5 18.258 W 8.9 13.9T54 W6 W8 W13 W14 W 18.921 W 14.424 W 13.528 W 12.735 W 1239 W49 W 9.554 W 6.480 W 4.5Technologyand capacityDesignNumber ofcellsTypeArticle no.Sick 3 Accu-NiCd 3A 898959<strong>60</strong> • •side by side 3 Accu-NiCd 3B 89895976 • •Assignable batteriesNiCd 4 AhD cellsStick 4 Accu-NiCd 4A 55 89800089 •side by side 4 Accu-NiCd 4B 89895977 •Stick + Stick 2 + 2 Accu-NiCd 4C 89895978 •Stick + Stick 3 + 3 Accu-NiCd 6C 89895963Stick 4 Accu-NiCd C4A 89899692 •NiCd 1.6 AhCs cellsNote:Stick + Stick 2 + 2 Accu-NiCd C4C 89899694 •side by side 4 Accu-NiCd C4B 89899693 •Stick 6 Accu-NiCd C6A 89899698 • •Stick + Stick 3 + 3 Accu-NiCd C6C 89899699 • •Not for use with TC-D / TC-T compact amalgam lamps.<strong>50</strong>°C batteries also available (see seperate datasheet at www.tridonic.com)Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 4


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERTechnologyand capacityNiCd 4 AhD cellsDesignBallast Lumen Factor (BLF) in %<strong>EM</strong> <strong>BASIC</strong> for linear lamps, 3 h3 h 3 cells 4 cellsType<strong>EM</strong> 33A<strong>BASIC</strong><strong>EM</strong> 33B<strong>BASIC</strong><strong>EM</strong> 33C<strong>BASIC</strong><strong>EM</strong> 34A<strong>BASIC</strong><strong>EM</strong> 34B<strong>BASIC</strong><strong>EM</strong> 34C<strong>BASIC</strong>Article no. 89818556 89818655 89800000 89818557 89818662 89800107Lamp type Wattage BLF in emergency <strong>lighting</strong> mode in % for rated operating timeT5 4 W 25 306 W 26 328 W 27 3213 W 25 3014 W 16 21 18.921 W24 W 13.528 W35 W39 W49 W54 W80 WT8 18 W 10 1<strong>230</strong> W 8.2 11.536 W 7.4 8.558 W 7.270 WNumber Typeof cellsArticle no.Assignable batteriesStick 3 Accu-NiCd 3A 898959<strong>60</strong> • •side by side 3 Accu-NiCd 3B 89895976 • •Stick 4 Accu-NiCd 4A 55 89800089 • • •side by side 4 Accu-NiCd 4B 89895977 • • •Stick + Stick 2 + 2 Accu-NiCd 4C 89895978 • • •Stick 5 Accu-NiCd 5A 89895973Stick + Stick 3 + 2 Accu-NiCd 5C 55 89800090Stick + Stick 3 + 3 Accu-NiCd 6C 89895963Note:Not for use with TC-D / TC-T compact amalgam lamps.<strong>50</strong>°C batteries also available (see seperate datasheet at www.tridonic.com)Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 5


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERTechnologyand capacityNiCd 4 AhD cellsDesignBallast Lumen Factor (BLF) in %<strong>EM</strong> <strong>BASIC</strong> for linear lamps, 3 h3 h 5 cells 6 cellsType<strong>EM</strong> 35A<strong>BASIC</strong><strong>EM</strong> 35B<strong>BASIC</strong><strong>EM</strong> 36A<strong>BASIC</strong><strong>EM</strong> 36C<strong>BASIC</strong><strong>EM</strong> 36CHO <strong>BASIC</strong>Article no. 89818581 89818667 89818654 89800108 89800109Lamp type Wattage BLF in emergency <strong>lighting</strong> mode in % for rated operating timeT5 4 W 37 446 W 40 488 W 40 4813 W 37 4414 W 28.521 W 14.424 W 1928 W 12.735 W 1239 W49 W 9.554 W 6.480 W 4.5T8 18 W 18 13.<strong>230</strong> W 12.5 12.536 W 15.3 1058 W 7.370 W 7Number Typeof cellsArticle no.Assignable batteriesStick 3 Accu-NiCd 3A 898959<strong>60</strong>side by side 3 Accu-NiCd 3B 89895976Stick 4 Accu-NiCd 4A 55 89800089side by side 4 Accu-NiCd 4B 89895977Stick + Stick 2 + 2 Accu-NiCd 4C 89895978Stick 5 Accu-NiCd 5A 89895973 • •Stick + Stick 3 + 2 Accu-NiCd 5C 55 89800090 • •Stick + Stick 3 + 3 Accu-NiCd 6C 89895963 • •Note:Not for use with TC-D / TC-T compact amalgam lamps.<strong>50</strong>°C batteries also available (see seperate datasheet at www.tridonic.com)Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 6


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERBallast Lumen Factor (BLF) in %<strong>EM</strong> <strong>BASIC</strong> for compact lamps, 3 h3 h 3 cells 4 cellsType<strong>EM</strong> 33A<strong>BASIC</strong><strong>EM</strong> 33B<strong>BASIC</strong><strong>EM</strong> 33C<strong>BASIC</strong><strong>EM</strong> 34A<strong>BASIC</strong><strong>EM</strong> 34B<strong>BASIC</strong><strong>EM</strong> 34D<strong>BASIC</strong>Article no. 89818556 89818655 89800000 89818557 89818662 89800175Lamp type Wattage BLF in emergency <strong>lighting</strong> mode in % for rated operating timeTC-DD 10 W 27 3016 W 24 2421 W 2028 W 1938 W55 WTC-SEL 5 W 207 W 149 W 1111 W 16TC-DEL 10 W 1313 W 15,418 W26 W 6.7 8.5TC-TEL 13 W 12.318 W26 W 6.7 7.532 W42 WTC-L 18 W 18 1824 W 1734 W 9136 W 9140 W 7.355 W 6Technologyand capacityDesignNumberof cellsTypeArticle no.Assignable batteriesStick 3 Accu-NiCd 3A 898959<strong>60</strong> • • •side by side 3 Accu-NiCd 3B 89895976 • • •Stick 4 Accu-NiCd 4A 55 89800089 • •NiCd 4 AhD cellsside by side 4 Accu-NiCd 4B 89895977 • •Stick + Stick 2 + 2 Accu-NiCd 4C 89895978 • •Stick 5 Accu-NiCd 5A 89895973Stick + Stick 3 + 2 Accu-NiCd 5C 55 89800090Stick + Stick 3 + 3 Accu-NiCd 6C 89895963Note: Not for use with TC-D / TC-T compact amalgam lamps.<strong>50</strong>°C batteries also available (see seperate datasheet at www.tridonic.com)1Used only in maintained mode because mercury migration may occur during emergency operation.Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 7


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERTechnologyand capacityNiCd 4 AhD cellsDesignBallast Lumen Factor (BLF) in %<strong>EM</strong> <strong>BASIC</strong> for compact lamps, 3 h3 h 5 cells 6 cellsType<strong>EM</strong> 35A<strong>BASIC</strong><strong>EM</strong> 35C<strong>BASIC</strong><strong>EM</strong> 35D<strong>BASIC</strong><strong>EM</strong> 36A<strong>BASIC</strong>Art. Nr. 89818581 89800001 89899621 89818654Lamp type Wattage BLF in emergency <strong>lighting</strong> mode in % for rated operating timeTC-DD 10 W 39 4616 W 31 3721 W 25 3028 W 21 2538 W 15 1855 W 14TC-SEL5 W7 W9 W11 WTC-DEL10 W13 W18 W 13.426 W 11.8TC-TEL 13 W 15.518 W 11.826 W 1132 W 6.742 W 5.4TC-L 18 W 19 2224 W 20 2434 W 19 2236 W 20 18.540 W55 WNumber Typeof cellsArticle no.Assignable batteriesStick 3 Accu-NiCd 3A 898959<strong>60</strong>side by side 3 Accu-NiCd 3B 89895976Stick 4 Accu-NiCd 4A 55 89800089side by side 4 Accu-NiCd 4B 89895977Stick + Stick 2 + 2 Accu-NiCd 4C 89895978Stick 5 Accu-NiCd 5A 89895973 • •Stick + Stick 3 + 2 Accu-NiCd 5C 55 89800090 • •Stick + Stick 3 + 3 Accu-NiCd 6C 89895963 •Note:Not for use with TC-D / TC-T compact amalgam lamps.<strong>50</strong>°C batteries also available (see seperate datasheet at www.tridonic.com)Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 8


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTER<strong>Emergency</strong> Ballast Lumen Factor (EBLF) in % 1<strong>EM</strong> <strong>BASIC</strong>, 3 hDuration3 hCells 3 cells 3 cells 3 cells 4 cells 4 cells 4 cells 4 cells 5 cells 5 cells 5 cells 5 cells 6 cells 6 cells 6 cellsType<strong>EM</strong> 33A<strong>BASIC</strong><strong>EM</strong> 33B<strong>BASIC</strong><strong>EM</strong> 33C<strong>BASIC</strong><strong>EM</strong> 34A<strong>BASIC</strong><strong>EM</strong> 34B<strong>BASIC</strong><strong>EM</strong> 34C<strong>BASIC</strong>Lamp type Wattage EBLF in emergency <strong>lighting</strong> mode in % for rated operating timeT5 6 W8 W13 WT5 FH 14 W 13.3 21 16.6 25.621 W 12.428 W 1135 W 10.3T5 FQ 24 W 12.239 W49 W 8.254 W 480 W 3.8T8 15 W18 W 9.4 10.9 16.8 11.930 W 7.6 10.3 16.7 11.236 W 6.9 7.838 W 6.1 6.758 W70 WTC-DD 10 W16 W21 W28 W38 W55 WTC-SEL 7 W9 W11 WTC-DEL 10 W13 W 12.718 W 11.926 W 5.8 6.6 10.4TC-TEL 13 W 10.2 13.918 W 10.426 W 6.2 6.9 9.932 W 6.342 W 4.857 WT5c 22 W40 W55 WTC-F 18 W24 W36 WTC-L 18 W24 W36 W 16.740 W 6.555 W 5.31According to EN 61347-2-7: 2006; outstanding measurements in preparation.<strong>EM</strong> 34D<strong>BASIC</strong><strong>EM</strong> 35A<strong>BASIC</strong><strong>EM</strong> 35B<strong>BASIC</strong><strong>EM</strong> 35C<strong>BASIC</strong><strong>EM</strong> 35D<strong>BASIC</strong><strong>EM</strong> 36A<strong>BASIC</strong><strong>EM</strong> 36C<strong>BASIC</strong><strong>EM</strong> 36CHO <strong>BASIC</strong>Article no. 89818556 89818655 89800000 89818557 89818662 89800107 89800175 89818581 89818667 89800001 89899621 89818654 89800108 89800109Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 9


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTER<strong>Emergency</strong> Ballast Lumen Factor (EBLF) in % 1<strong>EM</strong> <strong>BASIC</strong>, 1 hDuration1 hCells 3 cells 3 cells 4 cells 4 cells 6 cells 6 cellsType<strong>EM</strong> 13B<strong>BASIC</strong><strong>EM</strong> 13E<strong>BASIC</strong><strong>EM</strong> 14B<strong>BASIC</strong><strong>EM</strong> 14C<strong>BASIC</strong><strong>EM</strong> 16C<strong>BASIC</strong><strong>EM</strong>16C HO<strong>BASIC</strong>Article no. 89895971 89899864 89899611 89800118 89800119 89800120Lamp type Wattage EBLF in emergency <strong>lighting</strong> mode in % for rated operating timeT5 6 W8 W13 WT5 FH 14 W 16.621 W 12.428 W 1135 W 10.3T5 FQ 24 W 12.239 W49 W 8.254 W 480 W 3.8T8 15 W18 W 19.7 22.<strong>230</strong> W36 W38 W58 W 7.670 WTC-DD 10 W16 W21 W28 W38 W55 WTC-SEL 7 W9 W11 WTC-DEL 10 W13 W18 W26 WTC-TEL 13 W18 W26 W32 W42 W57 WT5c 22 W40 W55 WTC-F 18 W24 W36 WTC-L 18 W24 W36 W40 W55 W1According to EN 61347-2-7: 2006; outstanding measurements in preparation.Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 10


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTER<strong>EM</strong> <strong>BASIC</strong> discharge current in Ampere [A] 1<strong>EM</strong> <strong>BASIC</strong>, 3 hDuration3 hCells 3 cells 3 cells 3 cells 4 cells 4 cells 4 cells 4 cells 5 cells 5 cells 5 cells 5 cells 6 cells 6 cells 6 cellsType<strong>EM</strong> 33A<strong>BASIC</strong><strong>EM</strong> 33B<strong>BASIC</strong><strong>EM</strong> 33C<strong>BASIC</strong><strong>EM</strong> 34A<strong>BASIC</strong><strong>EM</strong> 34B<strong>BASIC</strong><strong>EM</strong> 34C<strong>BASIC</strong>Lamp type Wattage Discharge current in Ampere [A] for rated operating timeT5 6 W8 W13 WT5 FH 14 W 1.1 0.8 1.1 121 W 0.828 W 135 W 1.1T5 FQ 24 W 1.139 W49 W 154 W 1.180 W 1.1T8 15 W18 W 0.8 0.7 0.8 0.630 W 1.1 1 1.1 0.836 W 0.8 0.738 W58 W 1.1 1.170 WTC-DD 10 W16 W21 W28 W38 W55 WTC-SEL 7 W9 W11 WTC-DEL 10 W13 W 1.118 W 0.926 W 0.7 0.7 1.1TC-TEL 13 W 1.1 0.718 W 0.926 W 0.8 0.7 1.132 W 1.042 W 1.357 WT5c 22 W40 W55 WTC-F 18 W24 W36 WTC-L 18 W24 W36 W 1.140 W 1.155 W 1.11According to EN 61347-2-7: 2006; outstanding measurements in preparation.<strong>EM</strong> 34D<strong>BASIC</strong><strong>EM</strong> 35A<strong>BASIC</strong><strong>EM</strong> 35B<strong>BASIC</strong><strong>EM</strong> 35C<strong>BASIC</strong><strong>EM</strong> 35D<strong>BASIC</strong><strong>EM</strong> 36A<strong>BASIC</strong><strong>EM</strong> 36C<strong>BASIC</strong><strong>EM</strong> 36CHO <strong>BASIC</strong>Article no. 89818556 89818655 89800000 89818557 89818662 89800107 89800175 89818581 89818667 89800001 89899621 89818654 89800108 89800109Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 11


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTER<strong>EM</strong> <strong>BASIC</strong> discharge current in Ampere [A] 1<strong>EM</strong> <strong>BASIC</strong>, 1 hDuration1 hCells 3 cells 3 cells 4 cells 4 cells 6 cells 6 cellsType<strong>EM</strong> 13B<strong>BASIC</strong><strong>EM</strong> 13E<strong>BASIC</strong><strong>EM</strong> 14B<strong>BASIC</strong><strong>EM</strong> 14C<strong>BASIC</strong><strong>EM</strong> 16C<strong>BASIC</strong><strong>EM</strong>16C HO<strong>BASIC</strong>Article no. 89895971 89899864 89899611 89800118 89800119 89800120Lamp type Wattage Discharge current in Ampere [A] for rated operating timeT5 6 W8 W13 WT5 FH 14 W 1.121 W 0.828 W 135 W 1.1T5 FQ 24 W 1.139 W49 W 154 W 1.180 W 1.1T8 15 W18 W 1.6 1.330 W36 W38 W58 W 2.270 WTC-DD 10 W16 W21 W28 W38 W55 WTC-SEL 7 W9 W11 WTC-DEL 10 W13 W18 W26 WTC-TEL 13 W18 W26 W32 W42 W57 WT5c 22 W40 W55 WTC-F 18 W24 W36 WTC-L 18 W24 W36 W40 W55 W1According to EN 61347-2-7: 2006; outstanding measurements in preparation.Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 12


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERStandards• according to EN <strong>50</strong>172• according to EN <strong>60</strong>598-2-22• EN 61347-2-7• EN <strong>60</strong>925• EN 5<strong>50</strong>15• EN 61000-3-2• EN 61000-3-3• EN 61547• EN <strong>60</strong>068-2-64• EN <strong>60</strong>068-2-29• EN <strong>60</strong>068-2-30Isolation and electric strength testing of luminairesElectronic devices can be damaged by high voltage. This has to be consideredduring the routine testing of the luminaires in production.According to IEC <strong>60</strong>598-1 Annex Q (informative only!) or ENEC 303-Annex A, eachluminaire should be submitted to an isolation test with <strong>50</strong>0 VDC for 1 second. Thistest voltage should be connected between the interconnected phase and neutralterminals and the earth terminal. The isolation resistance must be at least 2 MΩ.As an alternative, IEC <strong>60</strong>598-1 Annex Q describes a test of the electrical strengthwith 1,<strong>50</strong>0 VAC (or 1,414 x 1,<strong>50</strong>0 VDC). To avoid damage to the electronic devicesthis test must not be conducted.Batteries NiCdCase temperature range 0 °C to +55 °Cto ensure 4 years design lifeBattery voltage/cell1.2 VCapacity4.2 / 4.5 AhMax. short term temperature (reduced life-time) 70 °CPacking quantity5 pcs. per cartonConnection method: 4.8 x 0.5 mm spade welded to end of cellFor the stick batteries this connection is accessible after the battery end capshave been fitted.To inhibit inverter operation, only disconnect the batteries by removing the connectorfrom the battery spade tags.Electrical connectionsAn earthed starting aid is recommended.The module should be earthed by the fixings used to attach it to the luminaire.Terminal block type:Push wire and insulation displacementTerminal block capacity• Push wire: 0.5 to 1.5 mm 2 solid conductor• Insulation displacement: 0.5 mm 2 solid conductorWire strip length: 7.5 to 8.5 mmLamp lead length: 2,<strong>50</strong>0 mm max.The longer pair of leads should always be connected to terminals 3 and 8.CE markingThe modules are CE marked for compliance with the low voltage directive.Certificates of compliance are available to allow luminaires to be CE marked forcompliance with the <strong>EM</strong>C directive.Mechanical detailsChannel manufactured from 0.4 mm Galvatite galvanised steel.Cover manufactured from 0.4 mm white precoated steel.LED status indicator• Green• Mounting hole 6.5 mm diametre• Lead length 7<strong>50</strong> mm (Bezel supplied fitted to LED)• Insulation rating: 90 °CTest switch• Mounting hole 7 mm diametre• Length of test switch lead 5<strong>50</strong> mmBattery leads• Quantity: 1 red and 1 black• Length: 1000 mm (Accu NiCd 3B, 4B, 4C), 1300 mm (all others)• Wire type: 0.5 mm 2 solid conductor• Insulation temperature rating: 90 °CTermination 1Push on 4.8 mm receptacle to suit battery spade fitted with insulating coverTermination 29 mm stripped insulationTwo-piece batteries are supplied with a 200 mm lead with 4.8 mm receptacle ateach end and insulting covers to connect the separate sticks together.Wiring guidelinesTo ensure that a luminaire containing high frequency emergency <strong>units</strong> complieswith EN 5<strong>50</strong>15 for radio frequency conducted interference in both normal andemergency mode it is essential to follow good practice in the wiring layout.Within the luminaire the switched and unswitched <strong>50</strong> Hz supply wiring must berouted as short as possible and be kept as far away as possible from the lampleads.This means, for example, in a linear T8 or T5 luminaire the mains wiring shouldbe routed along one side of the luminaire body, while the wires to the emergencylamp from the emergency module are routed along the other side.The high frequency emergency lamp wiring contains “hot” leads at pins 1 and 6,which have high voltage to earth. These should be kept as short as possible andseparated from other wiring to minimize coupling. They also have a restrictionon capacitance to other wiring and earth of 100 pF, which must be observed toensure good lamp starting.With an earth connection of the metal case of the emergency module the noisesuppression can be further improved. The wiring of the earth should be kept asshort as possible.Through wiring may affect the emc performance of the luminaire.With the use of the fifth pole possible compatibility problems between the productscan be prevented. Depending on the luminaire wiring the radio suppressionin the emergency mode of operation can be further improved.Capacitive loading limits of lamp leads must not be exceeded. Note the capacitanceof the emergency lamp leads adds to the capacitance of the leads fromthe ballast to the <strong>EM</strong> <strong>BASIC</strong> module when considering ballast loading.Life-timeAverage life-time <strong>50</strong>,000 hours under rated conditions with a failure rate lessthan 10 %. Average failure rate of 0.2 % per 1,000 operating hoursData sheet 01/15-783-9Subject to change without notice.www.tridonic.com 13


<strong>Emergency</strong> <strong>lighting</strong> <strong>units</strong><strong>EM</strong> INVERTERCircuit diagramsBatt +veNeutralUn-Switched LineBatteryOrange (+)LED Pink (–)Batt -veOptional Test SwitchLinLout+NLOP-SwSw<strong>EM</strong> <strong>BASIC</strong><strong>Emergency</strong> module87654321* hot leads Switched LineLinLout8Batt +ve+7NeutralN6Un-Switched LineBatteryL <strong>EM</strong> <strong>BASIC</strong> 5<strong>Emergency</strong> lampOrange (+)O <strong>Emergency</strong> module 4LED Pink (–)P3Batt -ve-2PFCSw1Optional Test SwitchSwS<strong>Emergency</strong> lamp*hot leads<strong>series</strong> capacitor circuitChokeorChokeNeutralNon maintainedSingle lamp switch start circuit with conventional control gearSwitched LineLinLoutBatt +ve+NeutralNUn-Switched LineBatteryLOrange (+)OLED Pink (–)PBatt -ve-PFCSwOptional Test SwitchSw<strong>EM</strong> <strong>BASIC</strong><strong>Emergency</strong> module87654321S<strong>Emergency</strong> lampS*hot leadsSwitched LineLoutBatt +veNeutralUn-Switched LineBatteryOrange (+)LED Pink (–)Batt -veOptional Test SwitchLinLout+NLOP-SwSw<strong>EM</strong> <strong>BASIC</strong><strong>Emergency</strong> module87654321<strong>Emergency</strong> lampNeutral<strong>series</strong> capacitor circuitChokeorChokeLampNeutralELECTRONICBALLAST* Hot leadsTwin <strong>series</strong> switch start circuit with conventional control gearSingle lamp high frequency electronic ballastSwitched LineLoutBatt +veNeutralUn-Switched LineBatteryOrange (+)LED Pink (–)Batt -veOptional Test SwitchNeutralLinLout+NLOP-SwSw<strong>EM</strong> <strong>BASIC</strong><strong>Emergency</strong> moduleELECTRONICBALLAST87654321<strong>Emergency</strong> LampLamp* Hot leadsSwitched LineLoutBatt +veNeutralUn-Switched LineBatteryOrange (+)LED Pink (–)Batt -veOptional Test SwitchNeutralLinLout+NLOP-SwSw<strong>EM</strong> <strong>BASIC</strong><strong>Emergency</strong> moduleELECTRONICBALLAST87654321* Hot leads<strong>Emergency</strong> LampLampTwin <strong>series</strong> switch start circuit with high frequency electronic ballastTwin lamp high frequency electronic ballast (7 lamp lead connections)Switched LineLoutBatt +veNeutralUn-Switched LineBatteryOrange (+)LED Pink (–)Batt -veOptional Test SwitchLinLout+NLOP-SwSw<strong>EM</strong> <strong>BASIC</strong><strong>Emergency</strong> module87654321<strong>Emergency</strong> LampNeutralELECTRONICBALLASTLamp* Hot leadsTwin lamp high frequency electronic ballast (8 lamp lead connections)Data sheet 01/15-783-9Subject to change without notice.www.tridonic.com 14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!