11.07.2015 Views

Technical Databook - Belimo Actuators (Shanghai)

Technical Databook - Belimo Actuators (Shanghai)

Technical Databook - Belimo Actuators (Shanghai)

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Energy MeterDistributed by <strong>Belimo</strong>Data storageIn case of power failure, the Supercal 531 has two non-volatile EEPROMfor extensive data safety storage. In both EEPROM the data is updatedevery hour. The first non-volatile memory is located inside on the printedcircuit board of the relevant calibration and measurement part of theintegrator and stores the following data:- Parameters of the integrator and configuration parameter- Cumulated energy- Cumulated volume- Customer’s specific tariff- 15 monthly values- 32 maximum values- 32 average values- Two set day- Cumulated energy or volume on the set day- Operating hours- Date and time- MET serial number (integrator upper part, calibration and measurementpart)- Pulse value of the flow meterThe second non-volatile EEPROM is located on the printed circuit boardin the integrator base part and stores the following parameters:- MIO serial number (integrator base part, printed circuit board)- Identification number and customer number- Pulse value of additional meters 1 and 2- Cumulated values of additional meters 1 and 2- Unit of additional meters 1 and 2- M-bus address- Baud rate (M-bus)- Pulse value of the pulse output- Parameter setting of the analogue outputs- Alarm and threshold valueThis EEPROM ensures a smooth exchange of the calibration andmeasurement relevant part, without a new entering of the configurationof the communication.Cumulated energyBackupTest segmentFor energy unit displayed in kWh/MWh. The maximum energy that canbe displayed is 99,999,999; the number of decimals can be set at thefactory or by an authorised calibration laboratory.For examination and safety storage of the measurement results theSupercal stores all data in a non-volatile memory once per hour. Withpower supply failure all values are automatically updated and stored.Shown on the LCD display.V2.4. 08. 2011 . Subject to modificationCumulated volumeOperating hoursDisplayed in m 3 . The maximum displayable energy is 9,999,999.9, thenumber of decimals can be set at the factory or by an authorised calibrationlaboratory.Displayed in hours.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!