Faults, Problems, WarningsFaults (Equipment Protection Shutdowns)There are no Unit protection shutdown alarms; all such alarms are handled through the compressorcontrollers.Problems (Limit Alarms)The following alarms limit operation of the chiller in some way as described in the Action Taken column.Table 7, Controller Limit AlarmsDescription Occurs When: Action Taken ResetEvaporator Pump #1FaultEvaporator Pump #2FaultCondenser Pump #1FaultCondenser Pump #2FaultEntering EvaporatorWater TemperatureSensor FaultNo flow indicated for (5 sec) with Evaporator Pump #1 ONAND [the other pump is available (per the Evap PumpSP) AND has not faulted]No flow indicated for (5 sec) with Evaporator Pump #2 ONAND [the other pump is available (per the Evap PumpSP) AND has not faulted]No flow indicated for (5 sec) with Condenser Pump #1 ONAND [the other pump is available (per the Evap PumpSP) AND has not faulted]No flow indicated for (5 sec) with Condenser Pump #2 ONAND [the other pump is available (per the Evap PumpSP) AND has not faulted]Sensor fault AND leaving water reset is based on enteringwaterStart pump #2Start pump #1Start pump #2Start pump #1Reset mode isset to No ResetManualManualManualManualManual.(Reset modegoes back toEnteringWater)WarningsThe following “alarms” only generate a warning message to the operator. Chiller operation is not affected.Table 8, Controller WarningsDescription Occurs When: Action Taken ResetEntering Evaporator TemperatureSensor FaultEntering Condenser TemperatureSensor FaultLeaving Condenser TemperatureSensor FaultLiquid Line RefrigerantTemperature Sensor FaultController FunctionsD - EOMWC00905-10EN - 22/88Sensor is open or shorted Annunciation AutomaticSensor is open or shorted Annunciation AutomaticSensor is open or shorted Annunciation AutomaticSensor is open or shorted Annunciation AutomaticLeaving Water Temperature (LWT) ResetThe Active Leaving Water variable shall be set to the current Leaving Water Temperature (LWT) setpointunless modified by one of the reset methods below. (The current LWT setpoint is Cool LWT as determinedby the chiller mode.) The type of reset in effect is determined by the LWT Reset Type setpoint.Reset Type – NONEThe Active Leaving Water variable is set equal to the current LWT setpoint.Reset Type – RETURNThe Active Leaving Water variable is adjusted by the return water temperature.When the chiller mode = COOL, the Active Leaving Water variable is reset using the following parameters:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!