SMACNA Master Index of Technical Publications - Sheet Metal and ...
SMACNA Master Index of Technical Publications - Sheet Metal and ...
SMACNA Master Index of Technical Publications - Sheet Metal and ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
grille <strong>and</strong> register selection, RCSI 6.5<br />
hangers, RCSI 7.3<br />
induction, APP 8.7<br />
materials, RCSI 7.2<br />
metal guages, RCSI 7.1<br />
procedures, RCSI 6.1<br />
return air, RCSI 6.5<br />
rules <strong>of</strong> design, RCSI 6.3<br />
tables, APP 14.1; DD 14.1<br />
dimension, FSDG 5.4<br />
drains, PVC 21, 54<br />
ductulator, RCSI 6.1<br />
ductwork size, RCSI 6.1<br />
connections, DCS 2.21; PVC 18, 38, 54<br />
elbows, PVC 17<br />
end caps, PVC 21<br />
end reflection loss, DD 11.42<br />
end taps, DD 5.29<br />
fibrous glass, FGDC 1.1; RCSI 7.1<br />
fitting loss coefficients, DD 5.12<br />
flanges, PVC 18<br />
flat oval, DCS 3.11<br />
flexible, DCS 3.15; FGDC A.6<br />
formula derivation, RCDC 9.1<br />
friction loss, DD 5.12<br />
fume hoods, PVC 20, 55<br />
rectangular, PVC 17; RCSI 7.1<br />
round, PVC 17; RCSI 7.1<br />
segmented, PVC 17, 29<br />
sound, DD 11.36<br />
tables <strong>and</strong> charts, DD 14.6<br />
fitting loss coefficients, TAB 2.23<br />
fittings, PVC 5<br />
fixed corner, RCDC 7.37, 8.8<br />
flexible, FGDC A.6; PVC 18, 38, 54<br />
functional st<strong>and</strong>ards, DCS 7.1<br />
gaskets, PVC 18<br />
hangers <strong>and</strong> support, DCS 4.1; FRP 7.3;<br />
PVC 20; RCSI 7.5<br />
heat gain, DD 4.4, 5.27<br />
heat loss, DD 4.4, 5.27<br />
hinged corner, RCDC 7.46, 8.11<br />
hot gas/filler rod welding, PVC 16, 25, 28<br />
installation st<strong>and</strong>ards, DCS 1.7; LTM 1.2<br />
insulation, RCSI 2.13, 7.4<br />
APP HVAC Systems – Applications<br />
ASMM Architectural <strong>Sheet</strong> <strong>Metal</strong> Manual<br />
BSAR Building Systems Analysis &<br />
Retr<strong>of</strong>it Manual<br />
COM HVAC Systems Commissioning<br />
Manual<br />
DCS HVAC Duct Construction St<strong>and</strong>ards<br />
<strong>Metal</strong> <strong>and</strong> Flexible<br />
DD HVAC Systems Duct Design<br />
DEHG Ducted Electric Heat Guide for Air<br />
H<strong>and</strong>ling Systems<br />
ESAM Energy Systems Analysis <strong>and</strong><br />
Management<br />
FGDC Fibrous Glass Duct Construction<br />
St<strong>and</strong>ards<br />
<strong>SMACNA</strong> <strong>Master</strong> <strong>Index</strong><br />
FRP Thermoset FRP Duct<br />
Construction Manual<br />
FSDG Fire Smoke <strong>and</strong> Radiation Damper<br />
Guide for HVAC Systems<br />
FSE Food Service Equipment Guidelines<br />
GSSC Guide for Steel Stack Construction<br />
IAQ Indoor Air Quality – A Systems<br />
Approach<br />
IDC Accepted Industry Practice for<br />
Industrial Duct Construction<br />
KVS Kitchen Ventilation Systems<br />
Guidelines<br />
LAG Accepted Industry Practices for<br />
<strong>Sheet</strong> <strong>Metal</strong> Lagging<br />
LTM HVAC Air Duct Leakage Test<br />
Manual<br />
MGW The Manager’s Guide for Welding<br />
intermediate supports, RCDC 6.5<br />
internal supports, RCDC 6.2, 6.4<br />
joints, RNDC 8.4, 9.4, 10.4, 12.59, 15.3,<br />
15.4<br />
lagging, external, DD 11.29<br />
leakage, BSAR 7.1; DD 2.4, 4.7; DD LTM<br />
1.1; DD RCSI 7.6<br />
leakage classifications, DD 5.23; LTM 4.3<br />
leakage tests, DCS 1.9; LTM 1.4, 3.1, 5.1,<br />
A.8<br />
lining, DCS 2.25; RCSI 7.4<br />
load capacity tables, RCDC 7.59<br />
loads, RCDC 4.1<br />
longitudinal seams, DCS 1.66, 3.8; PVC 17<br />
louvers, DCS 5.3; PVC 21, 45<br />
material thickness, RCDC 4.5, 7.1<br />
materials, DCS 1.8, 3.3; PVC 53<br />
modifications, RCDC 6.1<br />
narrowscope tables, DCS A.13<br />
needs, IAQ 10.4<br />
noise, DCS 7.12<br />
obstructions, DCS 2.10<br />
<strong>of</strong>fsets, DCS 2.9; PVC 17, 33<br />
outlet, DD 6.4, 6.5<br />
outlet elbows, DD 6.4, 6.5<br />
overpressure, DCS 1.7, 6.20, 7.6<br />
panel load, RCDC 4.4<br />
penetration, FSDG 11.2<br />
performance requirements, DCS 1.3<br />
pressure changes, TAB 2.21<br />
pressure changes during flow, DD 5.11<br />
pressure classification, DCS 1.6<br />
pressure comparison by gauge, DCS A.23<br />
pressure-velocity classification, DCS 1.4,<br />
1.6<br />
rectangular, PVC 5<br />
rectangular (sound), DD 11.24<br />
reinforcing data, RCDC 7.55<br />
research, DD 5.28<br />
roughness factors, DD 14.8<br />
round, PVC 5<br />
saddles, RNDC 13.8, 13.24, 13.25<br />
seal class, DCS 1.9<br />
sealing, BSAR 7.6; RCS 7.6<br />
sealing materials, DCS 1.11; LTM 1.5<br />
OBUC IAQ Guidelines for Occupied<br />
Buildings Under Construction<br />
PVC Thermoplastic Duct (PVC)<br />
Construction Manual<br />
RCDC Rectangular Industrial Duct<br />
Construction St<strong>and</strong>ards<br />
RCSI Residential Comfort Systems<br />
Installation St<strong>and</strong>ards<br />
RNDC Round Industrial Duct Construction<br />
St<strong>and</strong>ards<br />
RSMG Residential <strong>Sheet</strong> <strong>Metal</strong> Guidelines<br />
SEIS Seismic Restraint Manual –<br />
Guidelines for Mechanical Systems<br />
TAB HVAC Systems Testing Adjusting<br />
<strong>and</strong> Balancing<br />
17