Powercom <strong>SMART</strong> <strong>KING</strong> UPS provides the most reliableprotection for mini-computers, business critical networkingfile servers, networking switches, hubs and telecommunicationequipments from transient surges, voltage fluctuations andpower blackouts. Rack mount styles are also available forcustomer's choice for rack optimized servers and othernetworking applications.SXL-3000A-RM (4U)<strong>SMART</strong> <strong>KING</strong>Powercom Smart King UPS comes in LED or LCD front panelfor easy status displaying. Smart King AL and XL Seriesprovide continuous rated capacity for continuous backup.The main unit of SMK AL series UPS excludes the internalbatteries and is capable of connecting external batteries tosupport longer backup time while XL series unit includesinternal batteries to provide the longer backup time.With UPSMON software included in the package for serversand workstations, IT administrators can provide safe systemshutdown and advanced UPS management(all major operating systems supported).SMK Series also supports SNMP card expansion toprovide more powerful web management featureson the UPS. Other than that, the Advanced BatteryManagement (ABM) ensures a highly reliable andavailable power solution with PowercomSmart King Series.Powercom Smart king Series isalways the best choice for yourpower solution.Ordering Information :TypeSMKSALSXLCapacity - (VA)600A - 600VA800A - 800VA1000A - 1000VA1250A - 1250VA1500A - 1500VA2000A - 2000VA2500A - 2500VA3000A - 3000VA5100A - 5100VASXL-1000APackage ModelTower Model - (Blank)19" rack-mount model 2U - RM (2U)19" rack-mount model 3U - RM (3U)19" rack-mount model 4U - RM (4U)19" rack-mount model 5U - RM (5U)SXL-1500A/2000A_ _ _ _SMK 2000A RM (3U) LED 220SXL-1000/1500/2000A-RM (3U)SXL-1000~3000A-RM (3U)System DisplayLED Indicatirs - LEDLCD Indicatirs - LCDSXL-3000AInput Voltage100V,110V,120V,127,208V,220V,230V,240V


XL Series :USBSITE WIRING FAULT LEDCOMMUNICATIONINTERFACE PORTEXT.BATTERY CONNECTORTEL/MODEM SPIKEPROTECTION PORTFUSE OR BREAKERSNMP (option)OUTLETSAC INPUTUSBSITE WIRING FAULT LEDCOMMUNICATIONINTERFACE PORTTEL/MODEM SPIKEPROTECTION PORTSNMP (option)EXT.BATTERYCONNECTORFUSE OR BREAKEROUTLETSAC INPUTSITE WIRING FAULT LEDCOMMUNICATIONINTERFACE PORTTEL/MODEM SPIKEPROTECTION PORTSNMP (option)EXT.BATTERYCONNECTOROUTPUT CIRCUIT BREAKERUSBOUTLETSINPUT CIRCUIT BREAKERSXL-1000AEXT. BATTERYCONNECTOR(optional)USB AC INPUTUPS OUTLETSSNMP(option)SPECIFICATIONTower ModelTEL/MODEM SPIKEPROTECTION PORTSXL-1000A19" Rack-mont Model SXL-1000A-RM(3U) SXL-1500A-RM(3U) SXL-2000A-RM(3U) SXL-3000A-RM(4U) SXL-5100A-RM(5U)INPUTOUTPUTCOOLINGFANCapacityVoltageFrequencyFUSEREMOTEPORTVoltage (on battery)Frequency (on battery)Voltage Regulation(AVR)SXL-1500A/2000A / SXL-3000A (220V)1000VASXL-1500A1500VASXL-2000A2000VA+/-25% at line input, single phase50 or 60Hz +/-5Hz (auto sensing)Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning50 or 60Hz +/-0.5%SXL-3000A (110V)SXL-3000A3000VAAC INPUTTERMINAL BLOCKSXL-5100A5100VAAVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal.AVR decrease output voltage 15% below input voltage if +9% to +25% of nominalPROTECTIONand FILTERINGBATTERYNET WEIGHTkg (lbs)DIMENSIONW x D x H (mm)Spike ProtectionUnit InputEMI/RFI filterOverload ProtectionTransfer TimeShort CircuitTowerProtectionBack up timeBuilt in fast chargerTower19" Rack-mont ModelTower12V / 7.2AH28 (61.6 lb)170 x 450 x 215(6.7" x 17.7" x 8.8")320 Joules, 2msFuse for 110V models Except 3000A, breaker for 220V models Except 1000A10dB at 0.15MHz, 50 dB at 30MHzUPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.31.5 (69.3 lb)6~8 milliseconds (typical), including detection timeUPS output cut off immediately or input fuse(or breaker) protection12V / 17AHAutomatic self-test & discharge protection, Replace battery indicatorIt depends on connecting loads and external battery packs46 (101.2 lb)27.6 (60.7 lb)12V / 17AHNominal : 5.5A, 3.5A~8A adjustable50 (110 lb)31.5 (69.3 lb)170 x 480 x 430(6.7" x 18.9" x 16.9")12V / 17AH57 (125.4 lb)51.5 (113.3 lb)170 x 550 x 430(6.7"x21.6"x16.9")12V / 17AH19" Rack-mont Model 12V / 7.2AH 12V / 34W 12V / 34W 12V / 51W 12V / 17AH81.8 (179.9 lb)81.8 (179.9 lb)214 x 710 x 500(8.4"x27.9" x19.7")19" Rack-mont Model483 x 560 x 130(19.0" x 22.0" x 5.1")483 x 560 x 178(19.0"x22.0"x7.0")483 x 710 x 214(19.0"x27.9"x8.4")SYSTEM DISPLAYALARMINTERFACEENVIRONMENTLED IndicatorsLCD IndicatorsBattery Back-upBattery LowOverloadDry contactRS232OptionAmbient operationAudible noiseStorage conditionSlow beeping sound (about 0.25Hz)Rapid beeping sound (about 1.00Hz)Continue beeping soundSends AC fail and battery low signals, and receives shutdown signal from computer.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!