Appendix A<br />

Focus Parameters<br />

Table A.1 gives all <strong>the</strong> individual values that were measured for <strong>the</strong> focus parameters<br />

shown in <strong>the</strong> equations on page 6.<br />

Table A.1: Focus parameters for different receivers (from Sept. 2007).<br />

RX F1 F2 F3 F4 F5 F6<br />

[mm] [mm] [mm] [mm] [mm] [arcmin]<br />

secondary focus<br />

110 105.8 −13.6 2.6 −9.0 30.3 27.0<br />

60 105.8 2.4 2.6 −9.0 27.1 27.0<br />

36 105.8 −2.6 2.6 −9.0 50.0 27.0<br />

28 103.3 −0.3 2.6 −9.0 54.9 27.0<br />

20 98.5 2.1 2.6 −9.0 52.0 27.0<br />

13 95.7 4.4 2.6 −9.0 54.5 27.0<br />

09 88.4 8.4 2.6 −9.0 51.3 27.0<br />

07 86.7 12.9 2.6 −9.0 52.4 27.0<br />

primary focus<br />

all 138.4 −15.9 −0.3 −15.0 150.7 0<br />