InstructionRe<strong>com</strong>mendedCorrective ActionDateInitials7. Perform standard (hard) paddles check in Manual mode.*(If hard paddles are not used with the defibrillator, go to Step 8.)a.Disconnect and examine cable for Replace paddles.cracking, damage, broken, or bentparts or pins.b.Connect paddles to defibrillator.c.Examine for paddle surface pittingand presence of dried or wet gel.d.Press LEAD. Select Paddles.e.On paddles, turn ENERGY SELECTdial to 10 JOULES.f. With paddles in paddle wells,press CHARGE button on paddle.g.Press only one (shock) button andrelease. Confirm that energy was notdischarged.h.Press the other (shock) button andrelease. Confirm that energy was notdischarged.i. Press both (shock) buttons andconfirm ABNORMAL ENERGY DELIVEREDmessage appears.j. Remove paddles from wells, andconfirm artifact on screen.k.Place paddle surfaces together, andconfirm flat line on screen.l. Return paddles securely to paddlewells.Replace paddles, or clean paddles.If selected energy does not change orcharging does not occur, obtain sparepaddles and repeat check. If problemcontinues, remove the defibrillator fromuse and contact a qualified servicetechnician.If energy discharges with one buttonpress, obtain spare paddles and repeatcheck.If message does not appear, obtain sparepaddles and repeat check. Ifproblem continues, remove thedefibrillator from use and contact aqualified service technician.If task fails, obtain spare paddles andrepeat check. If problem continues,remove the defibrillator from use andcontact a qualified service technician.8. Perform User Test if 3:00 am auto test results not available:a.Press OPTIONS.If User Test fails, remove the defibrillatorb.Select USER TEST in menu.from use and contact a qualified servicec.Confirm test results printed. technician.9. Check ECG printer for:Adequate paper supplyAbility to printAdd new paper, if necessary.If not working, contact a qualifiedservice technician.10.If using wireless data transmission, test transmission method:a.Establish a Bluetooth connection. If not working, contact a qualifiedb.Send a test transmission.service technician.11.Turn off defibrillator.(Press and hold ON for up to 2 seconds.)12.Confirm that the device is stowed,mounted, or positioned securely.* The defibrillator delivers up to 360 joules of electrical energy. Unless discharged properly, this electrical energy may cause serious personalinjury or death. Do not attempt to perform this test unless you are qualified by training and experience.© 2008 Physio-Control, Inc., Redmond, WA July 2008 MIN 3208012-000 / CAT 26500-002817

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!