INSTALLATION TIPS - Euro-Rite Cabinets
INSTALLATION TIPS - Euro-Rite Cabinets
INSTALLATION TIPS - Euro-Rite Cabinets
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />
SUPPORT<br />
<strong>INSTALLATION</strong> <strong>TIPS</strong><br />
Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />
Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />
Detailed cabinet assembly instructions come in Box A. If for some reason you are missing an assembly<br />
instruction, you can download a copy from our website www.eurorite.com. The following pages will have<br />
important information when installing some of our more unique type of cabinets.<br />
Installation screw kits are sold separately. One INS kit can install on average 7 cabinets. Be sure to order<br />
enough to complete your installation.<br />
BLIND CORNER WALL & BASE CABINETS<br />
Blind corner cabinets can be used when space is an issue and a traditional angle corner will not fi t.<br />
When installing these cabinets here are a few things to remember:<br />
www.eurorite.com<br />
1. You must “pull” the blind cabinet out from the wall<br />
far enough to clear the adjacent cabinet, door and<br />
hardware. On average that would be 2-4" for blind<br />
wall install and 7-9" for blind base install.<br />
2. A filler strip has to be installed between the blind<br />
panel and the adjacent cabinet. The filler strip must<br />
be greater than the projection of the handle on the<br />
adjacent cabinets.<br />
3. A 36" blind wall comes with 2 doors.<br />
VERSION 5 | 09142010<br />
7.9
VERSION 5 | 09142010<br />
7.10<br />
<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />
SUPPORT<br />
<strong>INSTALLATION</strong> <strong>TIPS</strong><br />
NON-STANDARD CORNER BASE CABINETS<br />
Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />
Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />
www.eurorite.com<br />
<strong>Euro</strong>-<strong>Rite</strong> offers a non-standard corner base option for versatility when designing a kitchen. You can increase<br />
or decrease one side of your corner base 3-6" to accommodate adjoining cabinetry when you just need that<br />
few extra inches.<br />
When installing non-standard corner cabinets here are a few things to remember:<br />
1. The cabinets are not directly mounted to the wall, there is a 5"<br />
space between the backboard and the wall<br />
2. You will receive a standard corner base cabinet along with an<br />
extension kit. The smaller, standard shelf extension is discarded.<br />
3. The assembly and adjustable shelves are a combination of 2<br />
pieces and are locked together with cam and dowel.<br />
4. The extended side can be either on the left or right side of the<br />
cabinet by flipping the shelves.<br />
5. The smaller of the 2 doors is always hinged to the cabinet.
<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />
SUPPORT<br />
<strong>INSTALLATION</strong> <strong>TIPS</strong><br />
DIAGONAL CORNER BASE CABINETS<br />
Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />
Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />
www.eurorite.com<br />
<strong>Euro</strong>-<strong>Rite</strong> offers 2 sizes of diagonal base cabinets. A 36" and a 42". These unique cabinets are popular for large<br />
kitchens. Both can fit a sink but the 42" is the only one large enough to fit a double basin sink. If you would like a<br />
sink in the 36", it has to be a single basin.<br />
When installing diagonal corner base cabinets here are a few things to remember:<br />
1. The cabinets are not directly mounted to<br />
the wall, there is a 5" space between the<br />
backboard and the wall.<br />
2. The CSB42 come with 2 doors<br />
3. The CDB36 comes with 1 door and an<br />
adjustable shelf that must be installed<br />
prior to the top shelf.<br />
4. Do not install a drawer bank or door/drawer<br />
unit on either side of these cabinets.<br />
5. Where a dishwasher is beside these<br />
cabinets, use a filler strip or DW gable to<br />
allow for space.<br />
VERSION 5 | 09142010<br />
7.11
VERSION 5 | 09142010<br />
7.12<br />
<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />
SUPPORT<br />
<strong>INSTALLATION</strong> <strong>TIPS</strong><br />
MICROWAVE CABINET<br />
An assembled<br />
AW2415<br />
An assembled<br />
MW2415<br />
Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />
Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />
www.eurorite.com<br />
We have developed a unique system for any microwave confi guration. The MW cabinet has an extended bottom<br />
shelf and no doors to house your microwave. This cabinet is available in either 24" or 30" width. It is to be<br />
assembled and attached to any 2 door wall cabinet. See page 2.37 for pricing.<br />
When using a microwave wall cabinet here are a few things to remember:<br />
15" GABLE DEPTH WALL CABINETS<br />
1. Verify height allowance when designing the space.<br />
2. Attach the MW cabinet to the wall cabinet carriage bolts.<br />
3. To cover the side seam, you can install a DC30.<br />
4. Usable depth is 16".<br />
<strong>Euro</strong>-<strong>Rite</strong> offers wall cabinets with 15" deep gables. The benefi t of using a cabinet with 15" deep gables (sides)<br />
is the ability to stagger different heights of cabinets to crown molding without an apple basket cut.<br />
1. **important** the INSIDE depth of the cabinet<br />
remains the same as our standard wall cabinets,<br />
11" deep.<br />
2. On a corner wall with 15" deep gables, you must<br />
increase the cabinet width by 3".<br />
3. Full 15" deep wall cabinets are available as a custom.<br />
See page 7.3 for available customs and pricing.<br />
4. Some framing/cleating is required to attach these<br />
cabinets to the wall.
<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />
SUPPORT<br />
<strong>INSTALLATION</strong> <strong>TIPS</strong><br />
HINGE <strong>INSTALLATION</strong> & ADJUSTMENT<br />
Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />
Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />
On a clean surface, install hinges into the door(s) by gently hammering the hinge until fully seated. Install<br />
the doors by attaching the hinges to the mounting plates on the cabinet and click into place.<br />
Adjust the hinges and move doors to fi ll any gaps.<br />
www.eurorite.com<br />
VERSION 5 | 09142010<br />
7.13
VERSION 5 | 09142010<br />
7.14<br />
<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />
SUPPORT<br />
<strong>INSTALLATION</strong> <strong>TIPS</strong><br />
MOLDING & VALANCE <strong>INSTALLATION</strong><br />
Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />
Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />
It is important to know how to properly install moldings. <strong>Euro</strong>-<strong>Rite</strong> offers 4 different types of crown:<br />
CM = standard<br />
CMS = shaker crown<br />
CMC = colonial crown<br />
CMB = bull-nose crown and 2 different valance options<br />
This chart shows what crown options you have with our door styles. See page 4.3 for crown prices.<br />
DOOR STYLE TYPE OF CROWN<br />
San Juan (R) CM, CMC<br />
Saltspring (FO) CM, CMC<br />
Bowen (RO) CM, CMC<br />
Cortes (M) CM, CMS, CMC<br />
Rainier (RM) CM, CMS, CMC<br />
Cascade (RA) CM, CMS, CMC<br />
Monterrey (AB, OW, BW, CP, FM) CMB, CM*, CMS* (*chocolate pear only)<br />
Santos (VW, VAW) CM, CMS, CMC<br />
Solaire (FPW, FPCP, FPWC) CM, CMS, CMC<br />
Seymour (FAW) CM, CMS, CMC<br />
Capilano (RAW) CM, CMS, CMC<br />
Cyprus (SCPS, SWCS, SSS, SHNS) CM, CMS, CMC<br />
Langdale (RCPS, RWCS, RSS, RHNS) CM, CMS, CMC<br />
When installing molding there are a few options. This diagram shows all the applicable applications.<br />
Tips to Remember:<br />
1. Ceilings are not always square.<br />
www.eurorite.com<br />
2. With an 8" ceiling and 42"H upper wall cabinets, crown should not be used. 36"H are ok to use.<br />
See the following chart for molding installation diagrams.
<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />
SUPPORT<br />
<strong>INSTALLATION</strong> <strong>TIPS</strong><br />
OPTIONS FOR INSTALLING CROWN & VALANCE DIAGRAMS<br />
CROWN TO CEILING-FLUSH TO CABINET CROWN TO CEILING-FLUSH TO DOOR<br />
CABINET<br />
CABINET<br />
CABINET<br />
CEILING<br />
D<br />
O<br />
O<br />
R<br />
D<br />
O<br />
O<br />
R<br />
1<br />
CROWN MOULDING - SHAKER<br />
CABINET<br />
CEILING<br />
2 1/2” 2 1/2” 2 1/2”<br />
1 7/8”<br />
1 3/8”<br />
CROWN MOULDING<br />
2 1/4”<br />
D<br />
O<br />
O R<br />
CABINET<br />
D<br />
O<br />
O R<br />
SCRIBE TO CEILING-FLUSH TO CABINET<br />
CEILING CEILING<br />
D<br />
O<br />
O<br />
R<br />
2<br />
MONTERREY BULLNOSE CROWN<br />
Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />
Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />
CABINET<br />
D<br />
O<br />
O R<br />
D<br />
O<br />
O<br />
R<br />
CABINET<br />
www.eurorite.com<br />
CROWN TO CEILING-FLUSH TO DOOR WITH<br />
INSET RISER<br />
SCRIBE TO CEILING-FLUSH TO DOOR<br />
4 5 6<br />
7<br />
PROFILE VALANCE-SET BACK<br />
D<br />
O<br />
O R<br />
1/2”<br />
Set<br />
Back<br />
CABINET<br />
CABINET<br />
10<br />
D<br />
O<br />
O R<br />
CEILING<br />
CABINET<br />
PROFILE VALANCE-FLUSH WITH DOOR<br />
2 1/4”<br />
8 9<br />
D<br />
O<br />
O<br />
R<br />
REVERSE PROFILE VALANCE-SET BACK<br />
1 9/16”<br />
D<br />
O<br />
O<br />
R<br />
1/2”<br />
Set<br />
Back<br />
CABINET<br />
11<br />
3<br />
VERSION 5 | 09142010<br />
7.15
VERSION 5 | 09142010<br />
7.16<br />
<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />
SUPPORT<br />
<strong>INSTALLATION</strong> <strong>TIPS</strong><br />
MEASURING FOR COUNTERTOP & <strong>INSTALLATION</strong><br />
Countertop build up is required for all <strong>Euro</strong>-<strong>Rite</strong> base cabinets.<br />
Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />
Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />
BDE (Base Diagonal End) MEASUREMENTS FOR COUNTERTOP CUTTING<br />
Then measuring for countertops on this unique cabinet required, requires the specifi c sizes<br />
indicated on this diagram.<br />
11-3/4”<br />
300mm<br />
18”<br />
456mm<br />
23-5/8”<br />
600mm<br />
6-1/8”<br />
156mm<br />
8”<br />
203mm<br />
45 Degree Angle Cut<br />
www.eurorite.com