26.11.2012 Views

INSTALLATION TIPS - Euro-Rite Cabinets

INSTALLATION TIPS - Euro-Rite Cabinets

INSTALLATION TIPS - Euro-Rite Cabinets

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />

SUPPORT<br />

<strong>INSTALLATION</strong> <strong>TIPS</strong><br />

Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />

Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />

Detailed cabinet assembly instructions come in Box A. If for some reason you are missing an assembly<br />

instruction, you can download a copy from our website www.eurorite.com. The following pages will have<br />

important information when installing some of our more unique type of cabinets.<br />

Installation screw kits are sold separately. One INS kit can install on average 7 cabinets. Be sure to order<br />

enough to complete your installation.<br />

BLIND CORNER WALL & BASE CABINETS<br />

Blind corner cabinets can be used when space is an issue and a traditional angle corner will not fi t.<br />

When installing these cabinets here are a few things to remember:<br />

www.eurorite.com<br />

1. You must “pull” the blind cabinet out from the wall<br />

far enough to clear the adjacent cabinet, door and<br />

hardware. On average that would be 2-4" for blind<br />

wall install and 7-9" for blind base install.<br />

2. A filler strip has to be installed between the blind<br />

panel and the adjacent cabinet. The filler strip must<br />

be greater than the projection of the handle on the<br />

adjacent cabinets.<br />

3. A 36" blind wall comes with 2 doors.<br />

VERSION 5 | 09142010<br />

7.9


VERSION 5 | 09142010<br />

7.10<br />

<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />

SUPPORT<br />

<strong>INSTALLATION</strong> <strong>TIPS</strong><br />

NON-STANDARD CORNER BASE CABINETS<br />

Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />

Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />

www.eurorite.com<br />

<strong>Euro</strong>-<strong>Rite</strong> offers a non-standard corner base option for versatility when designing a kitchen. You can increase<br />

or decrease one side of your corner base 3-6" to accommodate adjoining cabinetry when you just need that<br />

few extra inches.<br />

When installing non-standard corner cabinets here are a few things to remember:<br />

1. The cabinets are not directly mounted to the wall, there is a 5"<br />

space between the backboard and the wall<br />

2. You will receive a standard corner base cabinet along with an<br />

extension kit. The smaller, standard shelf extension is discarded.<br />

3. The assembly and adjustable shelves are a combination of 2<br />

pieces and are locked together with cam and dowel.<br />

4. The extended side can be either on the left or right side of the<br />

cabinet by flipping the shelves.<br />

5. The smaller of the 2 doors is always hinged to the cabinet.


<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />

SUPPORT<br />

<strong>INSTALLATION</strong> <strong>TIPS</strong><br />

DIAGONAL CORNER BASE CABINETS<br />

Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />

Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />

www.eurorite.com<br />

<strong>Euro</strong>-<strong>Rite</strong> offers 2 sizes of diagonal base cabinets. A 36" and a 42". These unique cabinets are popular for large<br />

kitchens. Both can fit a sink but the 42" is the only one large enough to fit a double basin sink. If you would like a<br />

sink in the 36", it has to be a single basin.<br />

When installing diagonal corner base cabinets here are a few things to remember:<br />

1. The cabinets are not directly mounted to<br />

the wall, there is a 5" space between the<br />

backboard and the wall.<br />

2. The CSB42 come with 2 doors<br />

3. The CDB36 comes with 1 door and an<br />

adjustable shelf that must be installed<br />

prior to the top shelf.<br />

4. Do not install a drawer bank or door/drawer<br />

unit on either side of these cabinets.<br />

5. Where a dishwasher is beside these<br />

cabinets, use a filler strip or DW gable to<br />

allow for space.<br />

VERSION 5 | 09142010<br />

7.11


VERSION 5 | 09142010<br />

7.12<br />

<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />

SUPPORT<br />

<strong>INSTALLATION</strong> <strong>TIPS</strong><br />

MICROWAVE CABINET<br />

An assembled<br />

AW2415<br />

An assembled<br />

MW2415<br />

Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />

Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />

www.eurorite.com<br />

We have developed a unique system for any microwave confi guration. The MW cabinet has an extended bottom<br />

shelf and no doors to house your microwave. This cabinet is available in either 24" or 30" width. It is to be<br />

assembled and attached to any 2 door wall cabinet. See page 2.37 for pricing.<br />

When using a microwave wall cabinet here are a few things to remember:<br />

15" GABLE DEPTH WALL CABINETS<br />

1. Verify height allowance when designing the space.<br />

2. Attach the MW cabinet to the wall cabinet carriage bolts.<br />

3. To cover the side seam, you can install a DC30.<br />

4. Usable depth is 16".<br />

<strong>Euro</strong>-<strong>Rite</strong> offers wall cabinets with 15" deep gables. The benefi t of using a cabinet with 15" deep gables (sides)<br />

is the ability to stagger different heights of cabinets to crown molding without an apple basket cut.<br />

1. **important** the INSIDE depth of the cabinet<br />

remains the same as our standard wall cabinets,<br />

11" deep.<br />

2. On a corner wall with 15" deep gables, you must<br />

increase the cabinet width by 3".<br />

3. Full 15" deep wall cabinets are available as a custom.<br />

See page 7.3 for available customs and pricing.<br />

4. Some framing/cleating is required to attach these<br />

cabinets to the wall.


<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />

SUPPORT<br />

<strong>INSTALLATION</strong> <strong>TIPS</strong><br />

HINGE <strong>INSTALLATION</strong> & ADJUSTMENT<br />

Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />

Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />

On a clean surface, install hinges into the door(s) by gently hammering the hinge until fully seated. Install<br />

the doors by attaching the hinges to the mounting plates on the cabinet and click into place.<br />

Adjust the hinges and move doors to fi ll any gaps.<br />

www.eurorite.com<br />

VERSION 5 | 09142010<br />

7.13


VERSION 5 | 09142010<br />

7.14<br />

<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />

SUPPORT<br />

<strong>INSTALLATION</strong> <strong>TIPS</strong><br />

MOLDING & VALANCE <strong>INSTALLATION</strong><br />

Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />

Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />

It is important to know how to properly install moldings. <strong>Euro</strong>-<strong>Rite</strong> offers 4 different types of crown:<br />

CM = standard<br />

CMS = shaker crown<br />

CMC = colonial crown<br />

CMB = bull-nose crown and 2 different valance options<br />

This chart shows what crown options you have with our door styles. See page 4.3 for crown prices.<br />

DOOR STYLE TYPE OF CROWN<br />

San Juan (R) CM, CMC<br />

Saltspring (FO) CM, CMC<br />

Bowen (RO) CM, CMC<br />

Cortes (M) CM, CMS, CMC<br />

Rainier (RM) CM, CMS, CMC<br />

Cascade (RA) CM, CMS, CMC<br />

Monterrey (AB, OW, BW, CP, FM) CMB, CM*, CMS* (*chocolate pear only)<br />

Santos (VW, VAW) CM, CMS, CMC<br />

Solaire (FPW, FPCP, FPWC) CM, CMS, CMC<br />

Seymour (FAW) CM, CMS, CMC<br />

Capilano (RAW) CM, CMS, CMC<br />

Cyprus (SCPS, SWCS, SSS, SHNS) CM, CMS, CMC<br />

Langdale (RCPS, RWCS, RSS, RHNS) CM, CMS, CMC<br />

When installing molding there are a few options. This diagram shows all the applicable applications.<br />

Tips to Remember:<br />

1. Ceilings are not always square.<br />

www.eurorite.com<br />

2. With an 8" ceiling and 42"H upper wall cabinets, crown should not be used. 36"H are ok to use.<br />

See the following chart for molding installation diagrams.


<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />

SUPPORT<br />

<strong>INSTALLATION</strong> <strong>TIPS</strong><br />

OPTIONS FOR INSTALLING CROWN & VALANCE DIAGRAMS<br />

CROWN TO CEILING-FLUSH TO CABINET CROWN TO CEILING-FLUSH TO DOOR<br />

CABINET<br />

CABINET<br />

CABINET<br />

CEILING<br />

D<br />

O<br />

O<br />

R<br />

D<br />

O<br />

O<br />

R<br />

1<br />

CROWN MOULDING - SHAKER<br />

CABINET<br />

CEILING<br />

2 1/2” 2 1/2” 2 1/2”<br />

1 7/8”<br />

1 3/8”<br />

CROWN MOULDING<br />

2 1/4”<br />

D<br />

O<br />

O R<br />

CABINET<br />

D<br />

O<br />

O R<br />

SCRIBE TO CEILING-FLUSH TO CABINET<br />

CEILING CEILING<br />

D<br />

O<br />

O<br />

R<br />

2<br />

MONTERREY BULLNOSE CROWN<br />

Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />

Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />

CABINET<br />

D<br />

O<br />

O R<br />

D<br />

O<br />

O<br />

R<br />

CABINET<br />

www.eurorite.com<br />

CROWN TO CEILING-FLUSH TO DOOR WITH<br />

INSET RISER<br />

SCRIBE TO CEILING-FLUSH TO DOOR<br />

4 5 6<br />

7<br />

PROFILE VALANCE-SET BACK<br />

D<br />

O<br />

O R<br />

1/2”<br />

Set<br />

Back<br />

CABINET<br />

CABINET<br />

10<br />

D<br />

O<br />

O R<br />

CEILING<br />

CABINET<br />

PROFILE VALANCE-FLUSH WITH DOOR<br />

2 1/4”<br />

8 9<br />

D<br />

O<br />

O<br />

R<br />

REVERSE PROFILE VALANCE-SET BACK<br />

1 9/16”<br />

D<br />

O<br />

O<br />

R<br />

1/2”<br />

Set<br />

Back<br />

CABINET<br />

11<br />

3<br />

VERSION 5 | 09142010<br />

7.15


VERSION 5 | 09142010<br />

7.16<br />

<strong>Euro</strong>-<strong>Rite</strong> (RTA) Product Catalog<br />

SUPPORT<br />

<strong>INSTALLATION</strong> <strong>TIPS</strong><br />

MEASURING FOR COUNTERTOP & <strong>INSTALLATION</strong><br />

Countertop build up is required for all <strong>Euro</strong>-<strong>Rite</strong> base cabinets.<br />

Phone: 1 (888) 464-5063 OR 1 (604) 464-5060<br />

Fax: 1 (866) 881-4325 OR 1 (604) 464-7210<br />

BDE (Base Diagonal End) MEASUREMENTS FOR COUNTERTOP CUTTING<br />

Then measuring for countertops on this unique cabinet required, requires the specifi c sizes<br />

indicated on this diagram.<br />

11-3/4”<br />

300mm<br />

18”<br />

456mm<br />

23-5/8”<br />

600mm<br />

6-1/8”<br />

156mm<br />

8”<br />

203mm<br />

45 Degree Angle Cut<br />

www.eurorite.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!