11.07.2015 Views

D2 Digital Positioner

D2 Digital Positioner

D2 Digital Positioner

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>D2</strong> <strong>Digital</strong> <strong>Positioner</strong>ProductInformation


<strong>D2</strong><strong>D2</strong> is a digital positioner that is very simple andquick to set and calibrate, set DIP switches and press“Quick cal” button. Optional plug modules offers limitswitches. Communication via HART is possible.• Modular• Flexible• Rotary and Linear• Add in switches• VDI/VDE 3847• VDI/VDE 3845• HART option, <strong>D2</strong>• 4–20 mA Feedback option1. Add in switch option2. Gain adjustment3. Quick calibration4. Dip switch configuration5. LEDs for status indication1 5423<strong>D2</strong> HARTIntrinsically safe:ATEX II 1 G EEx ia IIC T4–T6CSA, FM Class 1, Div 1, Group ABCD


Technical dataInput signal4–20 mACompliance Voltage6 VDC, 12 V DC <strong>D2</strong> HARTSupply Voltage (max)30 V DCMin. operating current3,6 mAAngle of rotation (rotary) 0–90° normal(linear) 0–40° minimumSupply air quality Free from moisture, oil, dust ISA –7.0.01Input pressure range1,5–6 bar (22–87 psi)Air consumption0,12 Nm 3 /h @ 6 bar(4,12 SCFM @ 87 psi)Output signal0–100% of air supply pressureAir delivery capacity7 Nm 3 /h @ 6 bar (4,12 SCFM @ 87 psi)Linearity


Flexible mountingFlowact VDI/VDE 3847 VDI/VDE 3845Modular<strong>D2</strong> with optional mounting brackets and gauge block.


p/n: FCD PMENBR0003-02Hazardous LocationsATEX II 1 G EEx ia IIC T4–T6CSA, FM Class 1, Div 1, Group ABCDPalmstierna International ABKorta Gatan 9SE-171 54 SolnaSWEDENTel: +46 (0) 8 555 106 00Fax: +46 (0) 8 555 106 01E-mail: infopmv@flowserve.comGermanyFlowserveSperberweg 16D-41468 NeussGERMANYTel: +49 (0) 2131 795 74 80Fax: +49 (0) 2131 795 74 99E-mail: pmvgermany@flowserve.comUKFlowserveAbex RoadNewbury, Berkshire, RG14 5EYUKTel: +44 (0) 1635 46 999Fax: +44 (0) 1635 36 034E-mail: pmvukinfo@flowserve.comItalyFlowserve SpaVia Prealpi, 3020032 Cormano (Milano)ITALYTel: +39 (0) 2 663 251Fax: +39 (0) 2 615 18 63E-mail: infoitaly@flowserve.comUSA, MexicoPMV-USA1440 Lake Front Circle, Unit 160The Woodlands, TX 77380USATel: +1 281 292 7500Fax: +1 281 292 7760E-mail: pmvusa@flowserve.comCanadaCancoppas Limited2595 Dunwin Drive, Unit 2Mississuga, Ont L5L 3N9CANADATel: +1 905 569 6246Fax: +1 905 569 6244E-mail: controls@cancoppas.comRätt Grafiska AB Ordernr: 23591Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safelyduring its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions.Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimateresponsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation and Maintenance (I & M)instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application.While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes onlyand should not be considered certified or as a guarantee ofsatisfactory results by reliance thereon. Nothing contained herein is to be construedas a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve iscontinually improving andupgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning theseprovisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices.©2007 Flowserve Corporation, Irving, Texas, USA. Flowserve and PMV are registered trademarks of Flowserve Corporation.Asia Pacific HeadquartersFlowserve Pte Ltd.No. 12 Tuas Avenue 20REPUBLIC OF SINGAPORE 638824Tel: +65 (0) 687 98900Fax: +65 (0) 686 24940South AfricaFlowserveUnit 1, 12 Director RoadSpartan Ext. 21613 Kempton Park, GautengSOUTH AFRICATel: +27 (0) 11 397 3150Fax: +27 (0) 11 397 5300The NetherlandsFabromatic BVRechtzaad 174703 RC RoosendaalTHE NETHERLANDSTel: +31 (0) 30 6771946Fax: +27 (0) 30 6772471E-mail: fcbinfo@flowserve.comChinaFlowserveHanwei BuildingNo. 7 Guanghua RoadChao Yang District100004 BeijingCHINATel: +86 (10) 6561 1900Fax: +86 (10) 6561 1899www.pmv.nu