Preliminary Technical SpecificationsSampling, DilutionWith rotating disk diluter type <strong>Matter</strong> Engineering MD19-2EDilution ratio Adjustable Range 1:15 … 1:3000Hot dilutionHeating temperaturesMechanical set upAir supply part SpecificationAir Supply primary dilutionHeated dilution block and dilution air80/120/150° C adjustableDilution on separate exhaust probe for connection to sampling probeWith air supply <strong>Matter</strong> Engineering Type ASET-151.5 normative liter per minuteSecondary dilution factor 1 - 11Thermal Conditioner partHeating temperatureWith Evaporation tube <strong>Matter</strong> Engineering Type ASET-15Ambient – 400° C/752° FParticulate MeasurementNumber concentrationAccuracy, size range,response time ResolutionSystem controlFunctionalitySoftwareRemote PC-operationAdditional measuring signalsMechanical set upDimensionsWeightSupply voltageBy CPC, any model with RS 232 serial interfaceDepending on CPC modelWith digital control unit type <strong>Matter</strong> Engineering CU1-ETControl of dilution, thermal conditioning and sensor Measurement with real time datarecording of connected analog and serial signals.Logging speed adjustable up to 2 data sets per secondStandard software will be available for legal transient and constant load tests onvehicles and combustion enginesEthernet communication (TCP/IT)5 free analog inputs can be used to connect additional sensors and signalsAll 19”-modules mounted in mobile 19" cabinet or rackStandard type 55 (84 HP) x 30 (6U)x 60 cm (without pump & CPC)Standard type 60 kg90 – 260 V AC, 50/60 Hz, power consumption max. 300 VA (without pump & CPC)


Preliminary Technical SpecificationsNumber concentrationParticle size rangeCorrelationsCalibrationCommunicationData storageBattery life3·10³ … 1·10 6 #/cm³ (depends on particle size and sampling time constants)Measures 20 … 200 nmOperated in parallel to an SMPS system and sampled with 3 different aerosolsUsing SMPSrecommended every 1-2 yearsBluetoothUSBPCSD/MMC Memory cardApproximately 8 hoursDimensions (in cm) 34.2W x 26.3D x 9.8HWeightSample flowAccessoriesApprox 5.5 kgApprox 1.5 l/minUSB cable for data transferPower adapter, including car plug and charger for battery.Software for PC running Windows XPEssential spare partsDiSC is supplied in a portable carry bag with shoulder strap.The unit can be used with a removable SD/MMC Memory Card for full portability


• 2 s resolution time• measures number and sizesimultaneously• weighs 5.5 kg• battery life approx 8 hrs• measures 20 … 200 nm• suited for fi eld studies• no technical experience necessaryto operateMany aerosol instruments are large, heavy,fragile and expensive. DiSC was designedto avoid these characteristics with the aimto offer an instrument suitable for fieldmeasurements where accuracy and sizedistribution are not critical elements. It isthe fi rst of its kind on the market.DiSC is a modifi cation of the well knowndiffusion charger (DC). <strong>Aerosol</strong> is chargedand then passes through 3 measurementstages.In the diffusion stage, smaller particlesare deposited by diffusion while passingthrough a series of stainless steel grids.In the induction stage, aerosol passesthrough unobstructed.During a rapid concentration change, acurrent is induced in both this stage and inthe diffusion stage and is corrected for.Lastly, the filter stage consists of particlesbeing collected on a fi lter.Sensitive current amplifi ers measure the3 currents (induction, diffusion and filter)and their signals are digitalized.A data analysis software calculates numberand size and sends this via Bluetooth orUSB to a PC or can be saved directly ontoan SD/MMC memory card.DiSC is approximately as large as twolaptop computers placed on top of eachother.The portability of DiSC requires minimalset-up fuss and allows the ease of carryingDiSC in the field, for example, ambient airstudies of aerosol number concentrationsin urban areas.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!