Air Source Heat Pump Brochure - Evinox

Air Source Heat Pump Brochure - Evinox

Air Source Heat Pump Brochure - Evinox

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Heat</strong> <strong>Pump</strong> Solution with Back-Up BoilerWhere required, heat pumps can be effectivelyinstalled in central heating systems with a back-upboiler and control kit to reduce energy consumptionand heating costs. <strong>Evinox</strong> PHTJ, PHT and PHRT heatpumps have been designed to optimise the useof existing fossil fuel-fired installations.The heat pump will remain as the priority heatsource as long as its output remains optimal.Below a given outdoor temperature, the back-upboiler takes over the heating function, generallyincluding domestic hot water production.This considerably reduces energy consumption.Example AOil or gas-fired boiler and heat pump -zone 1 radiatorsOn/Off action on boiler and/or on valveK 60 D 066 Z regulation controls.Example BOil or gas-fired boiler and heat pump -zone 1 radiators or zone 2 underfloor heating-coolingProportional operation of mixing valveK 60 D 067 Z regulation controls.Example C1Oil or gas-fired boiler and heat pump - 2 mixed zones(zone 1 underfloor heating-cooling and zone 2 radiators)Proportional operation of underfloor mixing valveand radiator control valve.Proportional operation of underfloor mixing valveK 60 D 068 Z regulation controls.Example C2Oil or gas-fired boiler and heat pump- 2 underfloor heating-cooling zonesProportional operation of underfloor mixingvalve K 60 D 068 Z regulation controls.Control kitsK 60 D 066 Z - K 60 D 067 Z - K 60 D 068 ZThis electronic control system is used to control theentire installation (signal to run the boiler, with prioritygiven to the thermodynamic generator, ambienttemperature control).Simple to use for selecting different operating modes- Stop/<strong>Heat</strong>/Defrost - and to select a heating regime:Comfort or Economy (with hourly programmingoption in 2 zones).Typical installation with Back-Up BoilerExternal sensorValveControl unitBusBoilerPHRT, PHTor PHTJDecouplingbottleElectricalregualtion box


Technical DetailsModel PHTJ 14 PHTJ 14 PHTJ 19Code<strong>Heat</strong>ing230/1/50400/3N/50PHTJ 145 V--PHTJ 147 V-PHTJ 197 VFeaturesUnitsConditions: temperature water inlet/outlet 40/45°C and air intake 7/6°C (DB/WB); net values<strong>Heat</strong>ing capacity kW 14.3 14.1 20.7Input power kW 4.54 4.34 6.97COP (kW/kW) 3.15 3.25 2.97Conditions: temperature water inlet/outlet */45°C and air intake -7/-8°C (DB/WB); net values<strong>Heat</strong>ing capacity kW 8.6 8.4 12.8Input power kW 4.43 4.22 6.31COP (kW/kW) 1.94 1.99 2.03Conditions: temperature water inlet/outlet */55°C and air intake 7/6°C (DB/WB); net values<strong>Heat</strong>ing capacity kW 13.65 13.3 20.4Input power kW 5.33 5.04 7.55COP (kW/kW) 2.56 2.64 2.70Conditions: temperature water inlet/outlet 55/65°C and air intake 7/6°C (DB/WB); net values<strong>Heat</strong>ing capacity kW 13 12.5 20.1Input power kW 6.39 6.01 9.14COP (kW/kW) 2.03 2.08 2.2Conditions: temperature water inlet/outlet 30/35°C and air intake 7/6°C (DB/WB); net valuesCOP (kW/kW) 3.8 4.02 3.36Water flow with water outlet 45°C m³/h 2.55 2.43 3.45Available head pump Kpa 70 73 75Refrigerant type R 407 C R 407 C R 407 CNumber of refrigeration circuits n. 1 1 1Number of compressors n. 1 1 1Expansion tank volume l 2 2 2Ø of male water connector 1" 1" 1"Sound pressure level * dB(A) 39 39 45Net dimension (H./W./D.) mm 1235x1190x340 1235x1190x340 1235x1190x340Net weight Kg 141 141 145* Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 10m.Operating limitsHEATINGT. outdoor air: -16°C (DB) / +43°C (DB)T. water outlet maximum: +65°CT. water outlet minimum: +30°CAccessories PHTJ 14 PHTJ 19Set of two 1m flexible hoses 1" Dia. Remote control RS 485 Communication interface (MODBUS Protocol) Insulated buffer tank 35L 6 branch connection Insulated buffer tank 70L 6 branch connection Clearances150 700250 1000500Dimensions in mm7


60˚CDomestic High Temperature <strong>Heat</strong> <strong>Pump</strong>sPHT 13-16kW• <strong>Heat</strong>ing• Works down to -16°C outdoor temperature• T water outlet maximum: 60°C• High pressure scroll compressor• Three phase onlyFeatures• Water flow switch• LP switch• HP switch• Hydraulic filter (connectable)• Hydraulic equipment• Refrigerant fluid R 407 C• High coefficient of performance up to 3.67 COP• Extremely quite in operation withsound levels from 39dBACompact Dimensions1190 x 340 x 1235 mmHigh quality Components• High pressure scroll compressorwith sound insulation• High performance heat exchangerwith fins for the R 407 C axial fan motor• <strong>Heat</strong> exchanger with AISI 316 stainlesssteel plates and heat insulationHydraulic Equipment• 3 speed circulating pump• <strong>Air</strong> vent• Water manometer• Hydraulic filterFunctions of the Control System• Ability to reduce the minimum volume of water• Automatic control of the circulating pump(anti-freeze and anti-seize function)• Defrosting adjusted accordingto the outdoor temperature• Alarm management by means of event logging• External communication by a serial interface(Protocol Modbus)Other Features• Improved access to components• Keypad/display fitted to the front panel• Dividing bulkhead between the fanand the machinery compartment• Option of removing the ‘control’ panelfor a wider opening• Stringent manufacturing inspections:Helium waterproof test, di-electricaland electrical test, hydraulic test• Anti-freeze device on the base trayby means of a refrigerating circuit


Technical DetailsModel PHT 13 PHT 16Code 400/3N/50 PHT 137 V PHT 167 VFeaturesUnitsConditions: temperature water inlet/outlet 40/45°C and air intake 7/6°C (DB/WB); net values<strong>Heat</strong>ing capacity kW 12.3 15.4Input power kW 4.09 5.13COP (kW/kW) 3.01 3.00Conditions: temperature water inlet/outlet */45°C and air intake -7/-8°C (DB/WB); net values<strong>Heat</strong>ing capacity kW 7.4 9.3Input power kW 4.16 5.22COP (kW/kW) 1.78 1.78Conditions: temperature water inlet/outlet */55°C and air intake 7/6°C (DB/WB); net values<strong>Heat</strong>ing capacity kW 11.4 14Input power kW 4.73 6.03COP (kW/kW) 2.41 2.32Conditions: temperature water inlet/outlet 30/35°C and air intake 7/6°C (DB/WB); net valuesCOP (kW/kW) 3.67 3.35Water flow with water outlet 45°C m³/h 2.09 2.7Available head pump Kpa 50 68Refrigerant type R 407 C R 407 CNumber of refrigeration circuits n. 1 1Number of compressors n. 1 1Expansion tank volume l 2 2Ø of male water connector 1" 1"Sound pressure level * dB(A) 39 40Net dimension (H./W./D.) mm 1235x1190x340 1235x1190x340Net weight Kg 135 147<strong>Heat</strong>ing* Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 10m.Operating limitsHEATINGT. outdoor air: -16°C (DB) / +43°C (DB)T. water outlet maximum: +60°CT. water outlet minimum: +30°CAccessories PHT 13 PHT 16Set of two 1m flexible hoses 1" Dia. Remote control RS 485 Communication interface (MODBUS Protocol) Insulated buffer tank 35L 6 branch connection Insulated buffer tank 70L 6 branch connection Clearances150 700250 1000500Dimensions in mm9


55˚CDomestic Medium Temperature <strong>Heat</strong> <strong>Pump</strong>sPHRT 7-17kW• <strong>Heat</strong>ing and cooling• Operating limits:T outdoor air: -16°C in heating mode(+43°C in cooling mode)T water outlet maximum: +55°C in<strong>Heat</strong>ing mode (+20°C in cooling)• Single or three phase optionsFeatures• Single phase current limiter start-up kit(PHRT 7/9/12 single -phase)• Water flow switch• Proportional head pressure control• LP switch• HP switch• Hydraulic filter (connectable)• Hydraulic equipment• Refrigerant fluid R 410 A• Exceptional coefficient of performance up to 3.94 COP• Extremely quite in operationwith sound levels from 37dBACompact Dimensions• 1190 x 340 x 735 mm• 1190 x 340 x 1235 mmHigh quality Components• Scroll compressor with sound insulation• High performance heat exchanger withfins for the R 410 A axial fan motor• <strong>Heat</strong> exchanger with AISI 316 stainlesssteel plates and heat insulationHydraulic Equipment• 3 speed circulating pump• Expansion tank• Safety valve• <strong>Air</strong> vent• Water manometer• Hydraulic filterFunctions of the Control System• Ability to reduce the minimum volume of water• Adjustment of the condensation pressure• Automatic control of the circulating pump(anti-freeze and anti-seize function)• Defrosting adjusted according tothe outdoor temperature• Alarm management by means of event logging• External communication by a serial interface(Protocol Modbus)Other Features• Improved access to components• Keypad/display fitted to the front panel• Dividing bulkhead between the fanand the machinery compartment• Option of removing the ‘control’ panelfor a wider opening• Stringent manufacturing inspections:Helium waterproof test, di-electricaland electrical test, hydraulic test


Technical DetailsModel PHRT 7 PHRT 9 PHRT 12 PHRT 16Code230/1/50400/3N/50PHRT 075 F-PHRT 095 FPHRT 097 FPHRT 125 FPHRT 127 F-PHRT 167 F<strong>Heat</strong>ingCoolingFeatures Units Mono/Three Mono/ThreeConditions: temperature water inlet/outlet 40/45°C and air intake 7/6 °C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity kW 7.2 9.17 / 9.2 10.5 / 12.4 15Input power kW 2.65 3.19 / 3.19 3.62 / 4.06 4.92COP (kW/kW) 2.72 2.87 / 2.88 2.9 / 3.05 3.05Conditions: temperature water inlet/outlet */45°C and air intake -7/-8°C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity kW 4.6 5 / 5.05 5.88 / 6.8 8.51Input power kW 2.87 3.23 / 3.23 3.77 / 4.25 5.38COP (kW/kW) 1.6 1.55 / 1.56 1.56 / 1.6 1.58Conditions: temperature water inlet/outlet */55°C and air intake 7/6°C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity kW 6 8.25 / 8.3 9.38 / 11.7 13.6Input power kW 3.04 3.75 / 3.75 4.04 / 4.73 5.96COP (kW/kW) 1.97 2.17 / 2.21 2.32 / 2.47 2.28Conditions: temperature water inlet/outlet 40/45°C and air intake 7/6°C (DB/WB); gross values; Eurovent<strong>Heat</strong>ing capacity kW 7.25 9.24 / 9.27 10.65 / 12.5 15.2Input power kW 2.56 3.12 / 3.1 3.48 / 4.1 4.83COP (kW/kW) 2.83 2.96 / 2.99 3.06 / 3.05 3.15Conditions: temperature water inlet/outlet 30/35°C and air intake 7/6°C (DB/WB); net valuesCOP (kW/kW) 3.33 3.4 / 3.44 3.66 / 3.84 3.94Water flow m³/h 1.19 1.58 / 1.55 1.87 / 2.16 2.7Available head pump Kpa 57 47 / 47 66 / 53 68Conditions: temperature water inlet/outlet 12/7°C and air intake 35°C (DB); gross values; EuroventCooling capacity kW 5.95 7.16 / 7.16 8.67 / 9.03 11.60Input power kW 2.67 3.23 / 3.18 3.5 / 3.78 5.11EER (kW/kW) 2.23 2.22 / 2.25 2.48 / 2.39 2.27Water flow m³/h 1.01 1.22 / 1.22 1.48 / 1.51 1.98Available head pump Kpa 64 59 / 59 82 / 80 84Refrigerant type R410A R410A R410A R410ANumber of refrigeration circuits n. 1 1 1 1Number of compressors n. 1 1 1 1Expansion tank volume l 2 2 2 2Ø of male water connector 3/4" 3/4" 1" 1"Sound pressure level ** dB(A) 37 37 39 40Net dimension (H./W./D.) mm 735x1190x340 735x1190x340 1235x1190x340 1235x1190x340Net weight Kg 98 98 128 133* Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 10m.Operating limitsHEATINGT. outdoor air: -16°C (DB) / +43°C (DB)T. water outlet maximum: +55°CT. water outlet minimum: +25°CCOOLINGT. outdoor air: +10°C (DB) / +43°C (DB)T. water outlet maximum: +20°CT. water outlet minimum: +5°CAccessories PHRT 7 PHRT 9 PHRT 12 PHRT 16Set of two 1m flexible hoses ¾" Dia. - -Set of two 1m flexible hoses 1" Dia. - - Condensate tank heating cord kit Remote control RS 485 Communication interface (MODBUS Protocol) Insulated buffer tank 35L 6 branch connection For clearances please refer to PHT details on page 911


40˚CDomestic Low Temperature <strong>Heat</strong> <strong>Pump</strong>sPHR 6-17kW• <strong>Heat</strong>ing and cooling• Operating limits:T outdoor air: -16°C in heating (+43°C in cooling)T water outlet maximum: +40°C in heating mode• Single phase and three phase optionsFeatures• Single phase current limiter start-up kit(PHR 6/8/11 single-phase)• Water flow switch• Proportional head pressure control• LP switch• HP switch• Hydraulic filter (connectable)• Hydraulic equipment• Refrigerant fluid R 410 A• Exceptional coefficientof performance up to 4.38 COP• Extremely quite in operationwith sound levels from 37dBACompact Dimensions1190 x 340 x 735 mm1190 x 340 x 1235 mmHigh quality Components• Scroll compressor(except PHR6 with rotary compressor)with sound insulation• High performance heat exchangerwith fins for the R 410 A axial fan motor• <strong>Heat</strong> exchanger with AISI 316 stainlesssteel plates and heat insulationHydraulic Equipment• 3 speed circulating pump• Expansion tank• Safety valve• <strong>Air</strong> vent• Water manometer• Hydraulic filterFunctions of the Control System• Ability to reduce the minimum volume of water• Adjustment of the condensation pressure• Automatic control of the circulating pump(anti-freeze and anti-seize function)• Defrosting adjusted accordingto the outdoor temperature• Alarm management by means of event logging• External communication by a serial interface(Protocol Modbus)Other Features• Improved access to components• Keypad/display fitted to the front panel• Dividing bulkhead between the fanand the machinery compartment• Option of removing the ‘control’ panelfor a wider opening• Stringent manufacturing inspections:Helium waterproof test, di-electricaland electrical test, hydraulic test


Technical DetailsModel PHR 6 PHR 8 PHR 11 PHR 15 PHR 17Code230/1/50400/3N/50PHR 065 F-PHR 085 FPHR 087 FPHR 115 FPHR 117 F-PHR 157 F-PHR 177 F<strong>Heat</strong>ingCoolingFeatures Units Mono/Three Mono/ThreeConditions: temperature water inlet/outlet 30/35°C and air intake 7/6°C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity kW 6.5 8.4 / 8.55 11.2 / 11.1 14.3 16.8Input power kW 1.86 2.2 / 2.18 2.85 / 2.7 3.64 4.57COP (kW/kW) 3.63 3.82 / 3.92 3.93 / 4.11 3.93 3.68Conditions: temperature water inlet/outlet */35°C and air intake -7/-8°C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity kW 4.2 4.71 / 4.8 6.65 / 6.5 7.63 9.07Input power kW 1.91 2.19 / 2.19 3.17 / 2.9 3.71 4.51COP (kW/kW) 2.2 2.15 / 2.19 2.1 / 2.24 2.06 2.01Conditions: temperature water inlet/outlet 30/35°C and air intake 7/6°C (DB/WB); gross values; Eurovent<strong>Heat</strong>ing capacity kW 6.8 8.45 / 8.6 11.25 / 11.2 14.5 17Input power kW 1.76 2.13 / 2.1 2.7 / 2.56 3.51 4.47COP (kW/kW) 3.86 3.97 / 4.1 4.17 / 4.38 4.13 3.80Water flow m³/h 1.19 1.44 1.91 2.48 2.81Available head pump Kpa 50 42 55 65 76Conditions: temperature water inlet/outlet 23/18°C and air intake 35°C (DB); gross values; EuroventCooling capacity kW 6.7 8.7 / 8.5 9.45 / 9.5 14.6 16.5Input power kW 2.08 2.94 / 2.77 3.33 / 3.12 4.37 6EER (kW/kW) 3.22 2.96 / 3.07 2.84 / 3.04 3.34 2.75Water flow m³/h 1.15 1.48 1.62 2.48 2.74Available head pump Kpa 50 41 72 65 79Refrigerant type R410A R410A R410A R410A R410ANumber of refrigeration circuits n. 1 1 1 1 1Number of compressors n. 1 1 1 1 1Expansion tank volume l 2 2 2 2 2Ø of male water connector 3/4" 3/4" 1" 1" 1"Sound pressure level * dB(A) 37 37 39 40 40Net dimension (H./W./D.) mm 735x1190x340 735x1190x340 1235x1190x340 1235x1190x340 1235x1190x340Net weight Kg 82 90 113 127 131* Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 10m.Operating limits (pure water)HEATINGT. outdoor air: -16°C (DB) / +20°C (DB)T. water outlet maximum: +40°CT. water outlet minimum: +25°CCOOLINGT. outdoor air PHR 6/8/11: 0°C (DB) / +43°C (DB)T. outdoor air PHR 15: -3°C (DB) / +43°C (DB)T. outdoor air PHR 17: -7°C (DB) / +43°C (DB)T. water outlet maximum: +25°CT. water outlet minimum: +5°C (except PHR 6: +10°C)Accessories PHR 6 PHR 8 PHR 11 PHR 15 PHR 17 PHR 20Set of two 1m flexible hoses ¾" Dia. - - - -Set of two 1m flexible hoses 1" Dia. - - Condensate tank heating cord kit Remote control RS 485 Communication interface (MODBUS Protocol) Clearances150 700250 100050013Dimensions in mm


50˚CInverter Medium Temperature <strong>Heat</strong> <strong>Pump</strong>sPHRIA and PHRIB 10-14kW• <strong>Heat</strong>ing and cooling• Full DC Inverter• Operating limits:T outdoor air: -16°C in heating mode(+43°C in cooling mode)T water outlet maximum: +50°C in <strong>Heat</strong>ing mode(+20°C in cooling)• Currently two single phase models available,with 22 single or three phase models beinglaunched shortly• PHRIA features an in-built immersion heaterfor supplementary heating• PHRIB does not feature an in-built immersionheater and is for use with a back-up boilerFeatures• Water flow switch• Proportional head pressure control• LP switch• HP switch• Hydraulic filter (connectable)• Hydraulic equipment• Outside temperature sensor• Room controller• Choice of 4kW or 6kW 2 stage electricimmersion heater (PHIA models only)• Refrigerant fluid R 410 A• Exceptional coefficient of performanceup to 4.02 COP• Extremely quite in operation withsound levels from 42dBACompact Dimensions1390 x 340 x 1380mm1390 x 420 x 1380mmHigh quality Components• Twin rotary compressor• High performance heat exchangerwith fins for the R 410 A axial fan motor• <strong>Heat</strong> exchanger with AISI 316 stainlesssteel plates and heat insulationHydraulic Equipment• 3 speed circulating pump• Expansion tank• Safety valve• <strong>Air</strong> vent• Water manometer• Hydraulic filterFunctions of the Control System• Ability to reduce the minimum volume of water• Adjustment of the condensation pressure• Automatic control of the circulating pump(anti-freeze and anti-seize function)• Defrosting adjusted accordingto the outdoor temperature• Alarm management by means of event loggingOther Features• Improved access to components• Keypad/display fitted to the front panel• Dividing bulkhead between the fanand the machinery compartment• Option of removing the ‘control’ panelfor a wider opening• Stringent manufacturing inspections:Helium waterproof test, di-electricaland electrical test, hydraulic test


Technical DetailsModel PHRIA 10 PHRIA 14 PHRIB 10 PHRIB 14Code 230/1/50 PHRIA 105 F PHRIA 145 F PHRIB 105 F PHRIB 145 F<strong>Heat</strong>ingCoolingFeaturesUnitsConditions: T water inlet/outlet 30/35°C and T air intake 7/6°C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity nominal min/max kW 10.2 (4.2 - 13.2) 13.5 (4.2 - 15.0) 10.25 (4.2 - 13.2) 13.56 (4.2 - 15.0)Input power nominal kW 2.53 3.37 2.51 3.38COP 4.02 4.00 4.08 4.01Conditions: T water inlet/outlet */35°C and air intake -7/-8°C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity nominal kW 5.8 7.85 5.85 7.88Input power nominal kW 2.42 3.20 2.39 3.25COP 2.4 2.45 2.45 2.46Conditions: T water inlet/outlet 30/35°C and air intake 7/6°C (DB/WB); net values; Eurovent<strong>Heat</strong>ing capacity (kW / COP) kW / COP 10.3 / 4.2 13.6 / 4.08 10.3 / 4.2 13.6 / 4.08Input power kW 2.45 3.33 2.45 3.33Water flow m³/h 1.8 2.3 1.8 2.3Available head pump Kpa 45 42 20 19Conditions: T water inlet/outlet 40/45°C and air intake 7/6°C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity nominal kW 9.5 12.9 9.55 12.95Input power kW 3.07 4.12 3.06 4.12COP 3.09 3.13 3.12 3.14Conditions: T water inlet/outlet */45°C and air intake -7/-8°C (DB/WB); net values; NF PAC<strong>Heat</strong>ing capacity kW 4.80 7.35 4.85 7.39Input power kW 2.68 3.70 2.65 3.69COP 1.79 1.99 1.83 2.0Conditions: T water inlet/outlet 40/45°C and air intake 7/6°C (DB/WB); net values; Eurovent<strong>Heat</strong>ing capacity (kW / COP) kW / COP 9.6 / 3.2 13.0 / 3.18 9.6 / 3.2 13.0 / 3.18Input power kW 3.00 4.09 3.00 4.09Water flow m³/h 1.65 2.20 1.65 2.20Available head pump Kpa 47 43 22 18Conditions: T water inlet/outlet 23/18°C and air intake 35°C (DB/WB); net values; Eurovent<strong>Heat</strong>ing capacity nominal (kW / EER) kW / EER 10.4 / 4.09 12.9 / 3.55 10.4 / 4.09 12.9 / 3.55Input power nominal kW 2.54 3.63 2.54 3.63Water flow m³/h 1.87 2.25 1.87 2.25Available head pump Kpa 43 42 15 18Conditions: T water inlet/outlet 12/7°C and air intake 35°C (DB/WB); net values; Eurovent<strong>Heat</strong>ing capacity nominal (kW / EER) kW / EER 6.8 / 2.7 9.0 / 2.5 6.8 / 2.7 9.0 / 2.5Input power nominal kW 2.52 3.56 2.52 3.56Water flow m³/h 1.20 1.55 1.20 1.55Available head pump Kpa 50 47 35 27Refrigerant type R410A R410A R410A R410ANumber of refrigeration circuits 1 1 1 1Number of compressors 1 1 1 1Expansion tank volume L 6 6 6 6Ø of male water connector 1" 1" 1" 1"Sound pressure level ** dB(A) 42 44 42 44Dimensions (H./W./D.) mm 1380x1390x340/420 1380x1390x340/420 1380x1390x340/420 1380x1390x340/420Weight Kg 135 152 129 146** Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 10mOperating limits (pure water)HEATINGT. outdoor air: -20°C (DB) / +35°C (DB)T. water outlet maximum: +50°CT. water outlet minimum: +25°CCOOLINGT. outdoor air: +10°C (DB) / +43°C (DB)T. water outlet maximum: +20°CT. water outlet minimum: +5°CAccessories PHRIA 10 PHRIA 14Set of two 1m flexible hoses 1" Dia. Insulated buffer tank 35L 6 branch connection Insulated buffer tank 70L 6 branch connection For clearances please refer to PHR details on page 1315


50˚CCommercial <strong>Heat</strong> <strong>Pump</strong>s <strong>Heat</strong>ing and CoolingPHRV 24-76kW• <strong>Heat</strong>ing and cooling• High efficiency performance• Manufactured from robust, high quality materials• Compact unitsHigh quality Components• Scroll compressor with sound insulation• <strong>Air</strong> heat exchanger: copper tubeswith aluminium fins• Axial fan motor with variable speed control• <strong>Heat</strong> exchanger with AISI 316 stainlesssteel plates and heat insulationFunctions of the control system• Buffer vessel not mandatory• Adjustment of the condensation pressure• Automatic control of the circulating pump(anti-freeze and anti-seize function)• Defrosting adjusted accordingto the outdoor temperature• Hydraulic equipment (circulating pumpwith control valve, expansion tank, safety valve,air vent, water manometer)• Hydraulic filter (connectable)• Condenser coil protection grille• Frost protection (for the compressor)• Alarm management by means of event logging• External communication by a serial interface(Protocol Modbus)• Output for controlling an additional deviceSimplified operation and maintenance• Keypad/display fitted to the front panel• Access panel to the electrical cabinet• Access panels at the side and at the front• Provision for HP and LP gauge connections• Holes to accommodate slingsFeatures• ON/OFF main switch• Proportional head pressure control• HP and LP switches• Water flow switch• Phase sequence tester


Technical DetailsModel PHRV 22 PHRV 25 PHRV 32 PHRV 36 PHRV 44 PHRV 50 PHRV 64 PHRV 72Code 400/3N/50 PHR 227 V PHR 257 V PHR 327 V PHR 367 V PHR 447 V PHR 507 V PHR 647 V PHR 727 V<strong>Heat</strong>ingCoolingFeaturesUnits<strong>Heat</strong>ing capacity kW 24 27.3 35.50 38.40 49 54 69.3 76Input power * kW 9 10.40 13.65 14.75 17.80 19 27 30.50COP * (kW/kW) 2.67 2.63 2.62 2.60 2.75 2.84 2.57 2.49Water flow m³/h 4.21 4.68 5.94 7.20 8.42 9.29 11.92 12.89Available head pump Kpa 185 145 140 95 215 180 150 120Cooling capacity kW 20.8 25.8 30.3 33.5 40.6 52.6 60.60 65Input power * kW 8.85 9.70 13.55 14.55 17.7 21.20 27.10 29EER * (kW/kW) 2.35 2.66 2.24 2.30 2.29 2.48 2.24 2.24Water flow m³/h 3.49 4.50 5.22 6.05 6.98 9.04 10.44 11.02Available head pump Kpa 215 160 200 165 250 200 210 200Refrigerant type R407C R407C R407C R407C R407C R407C R407C R407CNumber of refrigeration circuits n. 1 1 1 1 2 2 2 2Number of compressors n. 1 1 1 1 2 2 2 2Expansion tank volume l 8 8 8 8 18 18 18 18Ø of male water connector 1" 1/4 1" 1/4 1" 1/4 1" 1/4 1" 1/2 1" 1/2 1" 1/2 1" 1/2Sound pressure level ** dB(A) 51 50 52 54 50 48 52 57Net dimension (H./W./D.)mm1175x975x10501175x975x10501175x975x10501425x975x10501175x1955x10501175x1955x10501175x1955x10501425x1955x1050Net weight Kg 303 305 327 363 516 520 554 626* Gross value (without hydraulic pump)** Sound pressure: This level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 10m.Nominal conditionsHEATINGT. outdoor air: +7°C (DB)T. outdoor air: +6°C (WB)T. water inlet: +40°CT. water inlet: +40°CCOOLINGT. outdoor air: +35°CT. water inlet: +12°CT. water outlet: +7°COperating limits (pure water)HEATINGT. water outlet maximum: +50°CT. water outlet minimum: +30°CCOOLING T. water outlet maximum: +15°C except PHRV 36 e 72 : 20°CT. water outlet minimum: +4°COperating limits: please see technical instructionsClearancesAccessories PHRV 22 PHRV 25 PHRV 32 PHRV 36Set of four 25mm anti-vibration plates Set of two 1.5m flexible hoses 1 ½ " Dia. HP and LP pressure gauges – 1 set Remote control RS 485 Communication interface(MODBUS Protocol) Insulated buffer tank 150L 3000Accessories PHRV 44 PHRV 50 PHRV 64 PHRV 72Set of four 25mm anti-vibration plates Set of two 1.5m flexible hoses 1 ½ " Dia. HP and LP pressure gauges – 2 sets Remote control RS 485 Communication interface(MODBUS Protocol) Insulated buffer tank 300L 300(600 if usinga buffer tank)3001000600Dimensions in mm17


Domestic Water ChillersCHG 8-17kW• Refrigerant fluid: R 410 A• Excellent EER (Energy Efficiency Ratio)• Extremely quite in operationwith sound levels from 37dBA• Single and three phase optionsFeatures• Water flow switch• Proportional head pressure control• LP switch• HP switch• Hydraulic filter (connectable)• Hydraulic equipmentCompact units• 1190 x 340 x 735 mm• 1190 x 340 x 1235 mmHigh quality Components• Scroll compressor with sound insulation• High performance heat exchangerfor R 410 A axial fan motor• <strong>Heat</strong> exchanger with AISI 316 stainlesssteel plates and heat insulationFunctions of the control system• Reducing of the minimum water volume• Adjustment of the condensation pressure• Automatic control of the circulating pump(anti-freeze and anti-seize function)• Alarm management by means of event logging• External communication by a serialinterface (Protocol Modbus)Other features• Improved access to components• Keypad/display fitted to the front panel• Dividing bulkhead between the fanand the machinery compartment• Option of removing the ‘control’ panelfor a wider opening• Stringent manufacturing inspections:Helium waterproof test, di-electricaland electrical test, hydraulic test


Technical DetailsModel CH 8 CHG 11 CHG 15 CHG 17Code230/1/50400/3N/50CHG 085 FCHG 087 F-CHG 117 F-CHG 157 F-CHG 177 FFeatures Units Mono/ThreeCooling capacity kW 8.10 11.00 13.70 16.30Input power* kW 3.63 / 3.56 4.42 5.26 6.27EER* (kW/kW) 2.23 / 2.28 2.49 2.60 2.60Water flow m³/h 1.40 1.91 2.34 2.81Available head pump Kpa 42 55 68 75Refrigerant type R410A R410A R410A R410ANumber of refrigeration circuits n. 1 1 1 1Number of compressors n. 1 1 1 1Expansion tank volume l 2 2 2 2Ø of male water connector 3/4" 1" 1" 1"Sound pressure level** dB(A) 37 39 39 39Net dimension (H./W./D.) mm 735x1190x340 1235x1190x340 1235x1190x340 1235x1190x340Net weight Kg 87 120 123 130* Gross value (without hydraulic pump)** Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 10m.Nominal conditionsT. outdoor air: +35°CTT. water inlet: +12°CT. water outlet: +7°COperating limits (pure water)T. outdoor air CHG 8 and 15 : -10°C D.B./ +43°C D.B.T. outdoor air CHG 11: -7°C D.B./ +43°C D.B.T. outdoor air CHG 17: -4°C D.B./ +43°C D.B.T. water outlet maximum: +18°C (except CHG 17: +20°C)T. water outlet maximum: +5°CAccessories CHG 8 CHG 11 CHG 15 CHG 17Set of two 1m flexible hoses ¾" Dia. - - -Set of two 1m flexible hoses 1" Dia. - Insulated tank 50L Single start-up kit (For single phase model) - - -Remote control RS 485 Communication interface (MODBUS Protocol) Clearances150 700250 1000500Dimensions in mm19


Commercial Water ChillersCHGV 21-78kW• Refrigerant fluid: R 407 C• Manufactured from robust, high quality materials• Compact units• Excellent EER (Energy Efficiency Ratio)Features• ON/OFF main switch• Proportional head pressure control• HP and LP switches• Water flow switch• Phase sequence tester• Hydraulic equipment (circulating pumpwith control valve, expansion tank, safetyvalve, air vent, water manometer)• Hydraulic filter (connectable)• Condenser coil protection grilleHigh quality Components• Scroll compressor with sound insulation• <strong>Air</strong> heat exchanger: copper tubeswith aluminium fins• Axial fan motor with variable speed control• <strong>Heat</strong> exchanger with AISI 316 stainlesssteel plates and heat insulationFunctions of the control system• Reducing the minimum water volume• Adjustment of the condensation pressure• Automatic control of the circulating pump(anti-freeze and anti-seize function)• Alarm management by means of event logging• External communication by a serialinterface (Protocol Modbus)Simplified operation and maintenance• Keypad/display fitted to the front panel• Access panel to the electrical cabinet• Access panels at the side and at the front• Provision for HP and LP gauge connections• Holes to accommodate slings


Technical DetailsModel CHGV 22 CHGV 25 CHGV 32 CHGV 40 CHGV 50 CHGV 64 CHGV 72 CHGV 80Code 400/3N/50 CHG 227 V CHG 257 V CHG 327 V CHG 407 V CHG 507 V CHG 647 V CHG 727 V CHG 807 VFeaturesUnitsCooling capacity kW 20.7 23.8 31 39 47.6 62 67 78Input power* kW 8.3 10.40 13.40 14.80 20.60 26.40 28.80 29.40EER* (kW/kW) 2.49 2.29 2.31 2.64 2.31 2.35 2.33 2.65Water flow m³/h 3.56 4.18 5.33 6.73 8.21 10.66 11.52 13.43Available head pump Kpa 210 170 200 135 220 160 180 90Refrigerant type R407C R407C R407C R407C R407C R407C R407C R407CNumber of refrigeration circuits n. 1 1 1 1 2 2 2 2Number of compressors n. 1 1 1 1 2 2 2 2Expansion tank volume l 8 8 8 8 18 18 18 18Ø of male water connector 1" 1/4 1" 1/4 1" 1/4 1" 1/4 1" 1/2 1" 1/2 1" 1/2 1" 1/2Sound pressure level ** dB(A) 51 50 52 54 50 54 59 59Net dimension (H./W./D.)mm1175x975x10501175x975x10501175x975x10501425x975x10501175x1955x10501175x1955x10501175x1955x1050Net weight Kg 292 295 317 353 500 534 556 6061425x1955x1050* Gross value (without hydraulic pump)** Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 10 mNominal conditionsT. outdoor air: +35°CTT. water inlet: +12°CT. water outlet: +7°COperating limitsT. inlet air to condense: Standard with head pressure control: -10°C/ +45°CT. pure water outlet: +4°C/ +20°CConsult Technical for any special climatic conditions which differ significantly from the nominal conditionsClearancesAccessories CHGV 22 CHGV 25 CHGV 32 CHGV 40Set of four 25mm anti-vibration plates Set of two 1.5m flexible hoses 1 ½ " Dia. HP and LP pressure gauges – 1 set Remote control RS 485 Communication interface(MODBUS Protocol) Insulated buffer tank 150L 3000Accessories CHGV 50 CHGV 64 CHGV 72 CHGV 80Set of four 25mm anti-vibration plates Set of two 1.5m flexible hoses 1 ½ " Dia. HP and LP pressure gauges – 2 sets Remote control RS 485 Communication interface(MODBUS Protocol) Insulated buffer tank 300L 300(600 if usinga buffer tank)3001000600Dimensions in mm21


Typical System schematics<strong>Heat</strong> pump with EBS tank and heating (1 heating and 1 hot water circuit)HEATINGCIRCUITNRVIVMIXINGVALVEPUMPIVIVBUFFERVESSELDRVIVIVDHW CIRCULATION PUMPNRVBALANCING VALVEWALL OFBUILDINGHEATING AND COOLING ASHP(3 PHASE OR 230V DEPENDANTON MODEL. CHECK MANUAL)IVIVIVIVSTRAINER DIRTSEPERATORFLOW AND RETURNMODEL DEPENDANTDRVDHWSEC.PUMPSAFETY ZONEVALVE4IMMERSIONSPUR3 1IMMERSION2COMBINEDPRESSUREREDUCING &RELIEF VALVE KITMCWSINLETFLEXIBLE CONNECTIONSMUST BE USED TO AVOIDNOISE CONDUCTIONHOT WATERDRAW OFFDHWSTORAGETANKBALANCED COLD WATER SUPPLY<strong>Heat</strong> pump with back-up boiler and EBS tank (1 hot water and 1 heating circuit)HEATINGCIRCUITBOILERNRVMIXINGVALVEIVPUMPGASIVNRVVSIVBUFFERVESSELNOTEBALANCING & IV VALVESINCLUDED IN DECOUPLINGBOTTLE KITIVIVDRVDECOUPLINGBOTTLENRVIVBVIVIVIVDHW CIRCULATION PUMPNRVBALANCING VALVESAFETY ZONEVALVEWALL OFBUILDINGHEATING AND COOLING ASHP(3 PHASE OR 230V DEPENDANTON MODEL. CHECK MANUAL)DRVIVIV IV IVSTRAINER DIRTFLOW AND RETURNSEPERATORMODEL DEPENDANTFLEXIBLE CONNECTIONSMUST BE USED TO AVOIDNOISE CONDUCTIONDHWSEC.PUMPHOT WATERDRAW OFF3 1COMBINED4 2 PRESSUREREDUCING &IMMERSIONRELIEF VALVE KITSPUR IMMERSIONDHWSTORAGETANKBALANCED COLD WATER SUPPLYMCWSINLET


<strong>Heat</strong> <strong>Pump</strong> with Thermal Store (Hot water and heating)HEATINGCIRCUITNRVIVPUMPSECONDARY HOT WATERMIXINGVALVESECONDARYRETURN PUMPIVTHERMOSTATICBLENDING VALVEOUTLET HOT WATERIVIVNRVIVNRVPRVNRVNRVDRVZONEVALVETOPSENSORIVWALL OFBUILDINGMIDDLESENSORHEATING AND COOLING ASHP(3 PHASE OR 230V DEPENDANTON MODEL. CHECK MANUAL)IVBOTTOMSENSORIVIV IV IVZONEVALVETHERMAL STOREFLOW AND RETURNMODEL DEPENDANTSTRAINERDIRTSEPERATORP.REGULATING VALVEMCWS SUPPLYFLEXIBLE CONNECTIONSMUST BE USED TO AVOIDNOISE CONDUCTIONBALANCEDCOLD WATER SUPPLYRAW WATER QUICK FILL VALVEFILLING LOOP TO BE REMOVEDONCE INSTALLATION IS COMPLETE<strong>Heat</strong> pump with Thermal store and boiler for heating and coolingHEATINGCIRCUITCOOLING CIRCUITTO FCU’S OR CENTRALVENTILATION PLANTBOILERNRVSECONDARY HOT WATERMIXINGTHERMOSTATICVALVESECONDARYIV BLENDING VALVERETURN PUMPOUTLET HOT WATERIVPUMPIVIVGASIVNRVIVBUFFERVESSELPUMPZONEVALVENRVPRVNRVDRVDECOUPLING BOTTLETOPSENSORWALL OFBUILDINGNRVIVIVBVMIDDLESENSORHEATING AND COOLING ASHP(3 PHASE OR 230V DEPENDANTON MODEL. CHECK MANUAL)NOTEBALANCING & IV VALVESINCLUDED IN DECOUPLINGBOTTLE KITBOTTOMSENSORIVIV IV IVDRVCHANGE OVER VALVESBALANCINGVALVEZONEVALVETHERMAL STOREFLOW AND RETURNMODEL DEPENDANTFLEXIBLE CONNECTIONSMUST BE USED TO AVOIDNOISE CONDUCTIONSTRAINER DIRTSEPERATORNRVDRVBUFFERVESSELFORCOOLINGCIRCUITP.REGULATINGVALVEMCWS SUPPLYNOTEBUFFER VESSELSIZED TO SUIT WATERCONTENT OFCOOLING CIRCUITBALANCEDCOLD WATER SUPPLYRAW WATER QUICK FILL VALVEFILLING LOOP TO BE REMOVEDONCE INSTALLATION IS COMPLETE23


Integrated heating intelligence<strong>Evinox</strong> Limited. Blenheim House.1 Blenheim Road. Epsom. Surrey. KT19 9AP.T: +44 (0) 1372 722277 E: info@evinox.co.uk technical@evinox.co.ukwww.evinox.co.uk<strong>Evinox</strong> reserves the right to make changes and improvements which may necessitate alteration to the specification without prior notice. This is not a contractual document.2551046A