11.07.2015 Views

Vent-Axia Product Selector

Vent-Axia Product Selector

Vent-Axia Product Selector

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CI/SfB(57.7)7th Edition<strong>Vent</strong>-<strong>Axia</strong> <strong>Product</strong> <strong>Selector</strong>The UK’s Leading <strong>Vent</strong>ilation Company


Introduction<strong>Vent</strong>ilation SolutionsA warm welcome to the 7th Edition of the<strong>Vent</strong>-<strong>Axia</strong> <strong>Product</strong> <strong>Selector</strong>. In this brochure, you willfind everything you need for any ventilation job, as wellas a selection of other products such as heating, coolingand hand dryers.It would be easy to get depressed about a disappointing2012, where we had a Euro crisis in Europe as well asin football! There is good news however; the BuildingRegulations introduced in 2010 really have started to show some benefits with highersales of our Lo-Carbon products than ever before. The Building Regulations aremaking an increasingly significant impact on ventilation solutions in UK homes andwe are taking important steps on the road to delivering zero carbon housing in thiscountry. With the recent publications surrounding the Green Deal, and MVHR beingincluded for non-residential buildings, ventilation is playing an increasingly crucial rolein energy efficient refurbishment programmes.With the first round of ErP requirements being implemented from January 2013, it’simportant that you buy from a ventilation manufacturer that you can trust. As always,our sales force is there to offer advice and provide insight into the latest legislationchanges and with the new Building Regulations coming in April 2013, that will besooner than you think.As always, there are a number of new products included within this edition. Wewould like to focus your attention on two main areas; our Lo-Carbon range, and ourimproved Heating range. The newly upgraded Lo-carbon range of unitary residentialfans will be available from early 2013. We are rolling out a new range that featuresan hour run meter as standard on all Lo-carbon humidity controlled fans. No morequestions for landlords over fan operation if a tenant complains of mould growth.Also, our heating range has really been extended. From page 156 you can find theheating section which, as well as panel and storage heaters, now includes towel rails,aluminium radiators and radiant heating. We are confident that we can provide acredible alternative to your existing heating suppliers, with a brand that you can trust.Employing over 800 people across 4 manufacturing sites, we continue to invest inUK manufacturing.Being in control of manufacture of the component parts including motors andmouldings all within the UK, we reduce our lead times as well as our carbon footprint.<strong>Vent</strong>-<strong>Axia</strong> Group LtdCrawley - Unitary plastic fan manufacture Our largest total manufacturing and office space with over 230,000 sq. ft.housing the <strong>Vent</strong>-<strong>Axia</strong> Head Office as well as the Group Head Office. Manufacturing and warehouse space totals 108,000 sq. ft. Manufacture of plastic ventilation ranges Design and test facilities for rigorous product testing including safety, airflowand climate chambers – BEAB approved Head Office functions including Sales Office, Customer Services, TechnicalSupport and MarketingSwindon - Lo-Carbon DC Motor manufacture 80,000 sq ft factory Over 1 million motors supplied into the HVACmarket every year The key provider of ourLo-Carbon technologyReading - Plastic Moulding andextrusion manufacture 50,000 sq ft injection andextrusion factory running24 hours a day Over 30 injectionmoulding machines 5 extrusion lines for rigidand flexible ductDid you know that <strong>Vent</strong>-<strong>Axia</strong> has a range of tools available on our website that canhelp you select the heating and ventilation products that you need? You can alsosit online CPDs and book training courses; all helping to ensure the right productfor the right job is installed correctly and working first time. We also have an onlinetrade counter, frequently asked questions as well as up-to-date product availabilityand technical literature all at the click of a button. The <strong>Vent</strong>-<strong>Axia</strong> website really is aknowledge hub, provided to make your life easier. Visit the website today to find outmore; www.vent-axia.com. We feel this really strengthens our position as a supplierof ventilation and heating, whatever your application or need. This is all still backedby a nationwide 70 strong sales team and an unrivalled technical support groupbased in Crawley.Our commitment to quality and service runs right through the core of our business,through our supply chain to you; our customers. As always, we want you tell us if youthink there are areas we could be better in as we continue to be the best that we can.<strong>Vent</strong>-<strong>Axia</strong> - the First Name in <strong>Vent</strong>ilation.Lee Nurse, Marketing DirectorDudley - Systems and Industrialmanufacture Our largest site with120,000 sq footageof manufacturing andwarehousing space Manufacturing base for ourmetal products including SentinelDemand <strong>Vent</strong>ilation and Sentinel Totus Also the home of our heat recovery (MVHR) andMultivent (MEV) productsDudleyReadingCrawleySwindonT: 0844 856 0590


Introduction<strong>Vent</strong>-<strong>Axia</strong> FirstsAt <strong>Vent</strong>-<strong>Axia</strong> we have a history of innovation. Whenyou look at our heritage, it soon becomes clearwhy we have been the First name in <strong>Vent</strong>ilationsince our inception1936 – Marine engineer Joe Akester invented theunitary extractor fan ‘Silent 6’ made from Bakelitematerial. The original products featured DC motors.1945 – Following the Second World War, Sir WinstonChurchill bought two Silent 6 fans for his Chartwellhome. A copy of the cheque for £28.19s 8p is in <strong>Vent</strong>-<strong>Axia</strong>’s reception area at Crawley.1953 – The ‘X type’ fan was produced in 4 sizes andthe unique ‘R type’ controller enabled the fans to bereversed for the first time.1961 – <strong>Vent</strong>-<strong>Axia</strong> Standard Range was launchedand applications became more varied with the firstdedicated models for roof and wall mounting and evena model for commercial and military vehicles.1975 – The Universal fan range featured the first‘centrifugal’ shutter mechanism that allowed the shuttersto operate in both directions without pull cords.1985 – The T Series product range featured a patentedDC solenoid shutter and offered unique applicationslike In-Line and Dark Room models. Accessories likethe Direct Mount Spigot and wall terminations alsoenabled the fans to be used with ducting as a completeinstallation kit.1997 – Domestic energy efficient ventilation beganwith the launch of the Lo-Carbon range featuring aDC motor and patented shutter system that used noadditional power.2002 - Commercial fans became energy efficientwith Lo-Carbon T Series launched at Interbuild inBirmingham.2006 – The Sentinel range was developed as the first‘Demand’ ventilation system with energy efficient EC/DC motors.2007 – <strong>Vent</strong>-<strong>Axia</strong> launched the first complete Lo-Carbon ventilation range featuring Residential Fans,MEV, MVHR and Commercial Energy Efficientproducts.2008 – As part of the Sentinel family, Totus ‘Demand’Energy Recovery became the first low energycommercial ventilation system with a 90% efficientenergy recovery and EC/DC motor.2009 – Sentinel Kinetic becomes the first Lo-Carbonproduct with 90% heat recovery and cooker hoodfacility.2011 – Launch of the first 100mm Single Room HeatRecovery Unit ‘Lo-Carbon Tempra’.1985 – <strong>Vent</strong>-<strong>Axia</strong> was the first, (in fact the only) fancompany to be awarded the Royal Warrant bythe Queen for supplying unit ventilation to RoyalHouseholds.1992 – The 16th edition of IEE regulations ‘on siteguide’ was issued and <strong>Vent</strong>-<strong>Axia</strong> launched the firstSafety Extra Low Voltage fan to meet the requirementsfor electrical safety in bathrooms.1994 – The patented LuminAir became the first fan andlight combination and its IP57 protection made the unitelectrically safe for shower installation.W: www.vent-axia.com


IntroductionGeneral InformationTechnical AdviceFree technical, installation and sales advice is availablefrom the <strong>Vent</strong>-<strong>Axia</strong> Technical Support Centre.Distribution<strong>Vent</strong>-<strong>Axia</strong> products are available from all leadingindustrial fan stockists. For further information, or in caseof difficulty, please contact the <strong>Vent</strong>-<strong>Axia</strong> Sales Centrein Crawley.Sound Levels<strong>Vent</strong>-<strong>Axia</strong> has a state of the art sound testing facilityat Crawley (UK) providing sound power levels forcomparison purposes tested in accordance with ISO13347-1:2004 and ISO 13347-2:2004. This is aninternational standard that describes methods fordetermining sound power levels of fans in one-thirdoctave bandwidths to allow comparisons to be madebetween different products from different manufacturersin a fair and consistent manner.The data is not intended to equal the sound powerlevels experienced in any specific installation butenable the customer to compare different productsand make an informed decision on their requirements.Each installation will use different building materials thatcan have an effect on how sound is absorbed and/orreflected. It is therefore very difficult to predict the exactsound power levels exhibited in any given installation.PerformanceTested in <strong>Vent</strong>-<strong>Axia</strong> test laboratories, performancetesting is carried out in a balanced chamber test ductto BS 848: Part 1. This has a booster fan to overcomethe system resistance.The volume flow is measured by a pressure dropacross a calibrated orifice plate at the entry to thesystem.An adjustable damper provides a variable resistanceto the test fan enabling its performance characteristicsto be measured. The rated figures given are at free airperformance.BSEN ISO 9001<strong>Vent</strong>-<strong>Axia</strong> limited is certified by the British StandardsInstitution to BS EN ISO 9001 Cert. No. FM1792QAS No. 3284/37.Intellectual Property<strong>Product</strong>s shown in this catalogue include aspectswhich are protected under patent, copyright, designcopyright, registered design and trademark laws.<strong>Vent</strong>-<strong>Axia</strong> will take all necessary legal action in anypart of the world against any party found to bemanufacturing, distributing, selling or otherwise dealingwith any article which infringes the Company’s rightsin its products.GuaranteeApplicable to units installed and used in the UnitedKingdom.For details of guarantee outside he United Kingdom,contact your local supplier.Unless otherwise stated, <strong>Vent</strong>-<strong>Axia</strong> guarantees itsindustrial fans for the period indicated on individualpages from the date of purchase, against faultymaterial or workmanship in normal use.In the event of any part being found to be defective,the appliance will be repaired, or at the Company’soption, replaced, without charge, provided that:1. The product has been installed and used inaccordance with the instructions given witheach unit;2. The product has not been connected toan unsuitable electrical supply (the correctelectricity supply voltage is shown on theappliance rating label attached to the unit);3. The product has not been subjected to misuse,neglect or damage;4. The product has not been modified or repairedby any person not authorised by the Company;5. The application is within the specification ofthe unit;6. The product is connected to <strong>Vent</strong>-<strong>Axia</strong> switchgear;7. Thermal overload protection has been correctlyconnected;8. The product has been subject to regularmaintenance appropriate to the installation;9. When returning the product under guarantee,evidence of purchase is provided.Conditions of saleAll sales by <strong>Vent</strong>-<strong>Axia</strong> are made only upon the termsof the Company’s Conditions of Sale (www.vent-axia.com/help/conditions-sale), a copy of which may beobtained upon request.Online Heating & <strong>Vent</strong>ilation ToolsEach tool has been designed with you in mind,making it simple to use & effective to apply, visitwww.vent-axia.com/tools-services.Online <strong>Product</strong> <strong>Selector</strong>Our fully comprehensive online productselector tool. Choose from our completespecification range to best suit yourproject.Online CPD<strong>Vent</strong>-<strong>Axia</strong> offers a selection of CPDmaterial online. With the addition of aquestionnaire, you can independentlycomplete your chosen module at yourown convenience.Online Trade CounterDistributors with accounts can log in orregister to check our live stock system forprices & stock availability & also reviewyour previous trade orders.Online Heating CalculatorsBy using the <strong>Vent</strong>-<strong>Axia</strong> Online SizingGuides, you will be able to determinewhich product is suitable for you, helpingyou to achieve thermal comfort all yearround.Online <strong>Axia</strong>l Fan CalculatorAn interactive tool to help you calculatethe installed performance of an axialfan when its being tested with a vaneanemometer.W: www.vent-axia.com


Contents - <strong>Product</strong> <strong>Selector</strong>LO-CARBON RESIDENTIAL FANS 8-25Lo-Carbon VA100/SELV <strong>Axia</strong>l Bathroom/Toilet Fans 10-11Lo-Carbon Silhouette 100/SELV Bathroom/Toilet Fans 12-13Lo-Carbon Centra/SELV dMEV Unit 14-15Lo-Carbon Solo Plus/SELV Centrifugal Bathroom/Toilet Fans 16-17Lo-Carbon Minivent Ducted Bath/Shower Fan Kit 18Lo-Carbon <strong>Vent</strong>-A-light Ducted Bath/Shower Fan Kit 19Lo-Carbon Quadra/SELV Centrifugal Fans 20-21dMEV, MEV & PIV SYSTEMS 52-65Lo-Carbon Centra/SELV dMEV Unit 54-55Lo-Carbon Multivent MEV Unit 56Multivent MEV Unit 57Lo-Carbon Sentinel Multivent & Controllers 58-60Lo-Carbon Multivent MVDC-MS/MSH MEV Unit 61Lo-Carbon Pozidry Positive Pressure Unit 62-63Lo-Carbon Pozidry Compact Positive Pressure Unit 64-65Lo-Carbon Silhouette 125 Bathroom/Toilet Fans 22Lo-Carbon VA150 <strong>Axia</strong>l Kitchen & Utility Room Fans 23Lo-Carbon Silhouette 150 <strong>Axia</strong>l Kitchen Fans 24SINGLE ROOM dMVHR 66-73Lo-Carbon Tempra/SELV Single Rm Heat Recovery 68-69Lo-Carbon HR25 Solo Plus Single Rm Heat Recovery 70RESIDENTIAL FANS 26-51VA100/SELV 12 <strong>Axia</strong>l Bathroom/Toilet Fans 28-29Silhouette 100/SELV <strong>Axia</strong>l Bathroom/Toilet Fans 30-31Lo-Carbon HR25 Single Rm Heat Recovery 71HR200WK Single Rm Heat Recovery 72HR300 Single Rm Heat Recovery 73Silent Fan 100 <strong>Axia</strong>l Bathroom/Toilet Fans 32Silhouette 125 <strong>Axia</strong>l Bathroom/Toilet Fans 33LuminAir Fan & Light Combination Unit 34LuminAir Fan & Light <strong>Vent</strong>ilation Kit 35LuminAir Turbo Fan & Light <strong>Vent</strong>ilation Kit 36Solo Plus Centrifugal Bathroom/Toilet Fans 37Solo/SELV 12 Centrifugal Bathroom/Toilet Fans 38-39VA140/150 <strong>Axia</strong>l Kitchen Fans 40VA150 Window Mount <strong>Axia</strong>l Kitchen Fans 41Silhouette 150 <strong>Axia</strong>l Kitchen Fans 42Centrif Duo Centrifugal Kitchen & Utility Room Fans 43Centrif Duo Plus Centrifugal Kitchen & Utility Room Fans 44Duet Twin Bathroom/Toilet Run & Standby Fans 45Gemini Twin Kitchen/Utility Run & Standby Fans 46Freshvent Natural <strong>Vent</strong> 47Cooker Hoods 48Basics Range Basic, Simple, Solution 49Eclipse Bathroom & Kitchen <strong>Axia</strong>l Fan 50MVHR FOR COMMERCIAL & RESIDENTIAL 74-109Lo-Carbon Kinetic Range Overview 76-77Lo-Carbon Sentinel Kinetic Range Overview 78-79Lo-Carbon Sentinel Kinetic Plus MVHR Unit 80-83Lo-Carbon Sentinel Kinetic Cookerhood MVHR Unit 84-87Lo-Carbon Sentinel Kinetic MVHR Unit 88-91NEW Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit 92-95NEW Lo-Carbon Kinetic Plus E MVHR Unit 96-97Lo-Carbon Kinetic E MVHR Unit 98-99Integra Ducted MVHR Unit 100Integra Plus Ducted MVHR Unit 101HR100R/RS Ducted MVHR Unit 102HR200V Ducted MVHR Unit 103HR250 MVHR Unit 104HR400 MVHR Unit 105HR500 Single Rm Heat Recovery Unit 106HR500D Ducted MVHR Unit 107HR500EP/IP Passive MVHR Unit 108HR500DP Passive MVHR Unit 1096 T: 0844 856 0590


IntroductionDUCTING & FITTINGS 110-121ACCESSORIES & CONTROLLERS 172-193COMMERCIAL RANGE 122-143ACM 100-315 In-Line Mixed Flow Fans 124-125Powerflow In-Line Duct Fans 126-127Lo-Carbon T-series Window/Wall/Roof/Panel 128-131Traditional T-series Window/Wall/Roof/Panel/Darkroom/In-line132-137Super T-series Powerful Heavy Duty Wall Fans 138Traditional Standard Window/Roof/Wall/Panel 139-142HYGIENE 144-149Hand Dryers 146-148Insect Killers 149COOLING 150-155Jupiter De-Stratification Unit 152Hi-Line Plus Ceiling Sweep Fans 153Portable Air Conditioner 154Portable Cooling 155HEATING 156-171Bluethermal Underfloor Heating 158-161NEW Heated Towel Rails 162-163ROOF UNITS 194-229EuroSeries (ESP) Plate Mounted <strong>Axia</strong>l Fans 196-199EuroSeries (ESC) Short Case <strong>Axia</strong>l Fans 200-203EuroSeries (ESR) Roof Mounting <strong>Axia</strong>l Fans 204-207Fan Box (FB) In-Line Centrifugal Duct Fans 208-209Quiet Pack (QP) In-Line Centrifugal Duct Fans 210-211Quiet Pack (QPTW) In-Line Twin Fans 212-213Slimpack Fan (SLP) In-Line Centrifugal Duct Fans 214-215Slimpack Fan (SLPT) In-Line Twin Duct Fans 216-217EuroSeries (SDX) In-Line Centrifugal Duct Fans 218-219Speed Controllers Single & Three Phase 220-221Starter & Overloads 222Sonex Circular Sound Attenuators 223Pyrocheck (CVT) Intumescent Fire Dampers 224Pyrocheck (PA) Fusible Link Fire Dampers 225<strong>Vent</strong>ilex (VHD) Fire Protection Valves 226<strong>Vent</strong>ilex (VHE) Steel <strong>Vent</strong>ilation Valves 227Unitex Roof Cowl System 228Unitex Wall Terminal (SA & QSA) 229STOCK REFERENCE & PRICE LIST INDEX 230-243NEW Radiant Heaters 164-165NEW Opal Aluminium Radiators 166Optimax Plus Panel Heater 167Optimax Plus Combination Heater 168Optimax Plus Storage Heater 169Plinth Heaters 170Warm Air Curtains 170Downflow Heater 170Convector Heater 171Portable Fan Heater 171W: www.vent-axia.com 7


Lo-CarbonResidential FansContinuing our commitment to energy efficientproducts, we are proud to introduce ourLo-Carbon range. In this section you will find<strong>Vent</strong>-<strong>Axia</strong>’s Lo-Carbon solutions for anyintermittent and continuous fan application.In axial or centrifugal, wall, ceiling or windowapplications in bathrooms or kitchens we have aLo-Carbon fan offering up to 90% energy savingover the equivalent traditional fan.The newly upgraded Lo-carbon range of unitaryresidential fans will be available from early2013. We are rolling out a new range thatfeatures an hour run meter as standard on allLo-carbon humidity controlled fans. No morequestions for landlords over fan operation if atenant complains of mould growth.We are the first manufacturer in the UK toprovide such an inclusive offer at a price pointwhich makes these products a real alternative.Range8 T: 0844 856 0590


W: www.vent-axia.com 9


Lo-CarbonVA100®/SELV<strong>Axia</strong>l Bathroom/Toilet FansFeatures & Benefits Meets current Building RegulationsApproved Document F & L Suitable for wall, ceiling, panel andwindow mounting Fitted with a motorised shutter 5 Year Motor Guarantee Protected against low energy lightingcircuits Reduces your carbon footprint IPX4 rated - IPX7 rated (SELV) Efficient long life DC motor Uses up to 87% less energy Low sound levels 1 of 2 speeds selectable at installation Low specific fan power SELV Models - Supplied with a remotetransformer Datalogger as standard on all modelsLong Life <strong>Vent</strong>ilation VA100The improved <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon VA100 rangefeatures Lo-Carbon long life DC motors that aremore efficient than conventional motors whilstdelivering up to 87% energy savings.ShuttersThe <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon VA100 range is fitted witha motorised shutter mechanism that uses no extrapower in operation or off.InstallationFitted with integral protection against low energylighting circuits, the VA100 is a 100mm axial fansuitable for use in the bathroom or toilet. VA100is a quick and simple to fit product with easy-wireon one line terminals. Suitable for installation inwindow, walls or panels/ceilings at any angleusing kits available. The 100mm telescopic wall kitfit walls 225 to 360mm thick.The range meets the requirements of the currentBuilding Regulations for the ventilation of toilets6l/s and bathrooms 15l/s with a 15 minute overruntimer for internal rooms on the LT, XT and HTPmodels.ModelsLo-Carbon VA100/SELV LPDOM(Pullcord)Ultra long life DC motor. Pullcord On/Off overrideswitch with indication light. 2 speed options.Model Stock Ref £ TradeLP 443159 49.85SELV LP 441614 106.04Lo-Carbon VA100 XP/SELVDOM(Shutter/Pullcord)Ultra long life DC motor. Pullcord and On/Off override switch with indication light. 2speed options.Model Stock Ref £ TradeXP 443160 68.68SELV XP 459049 116.94Lo-Carbon VA100/SELV LTDOM(Timer)Electronic adjustable overrun timer (5-30 minutes).Indication light. 2 speed options.Model Stock Ref £ TradeLT 443161 61.59SELV LT 441615 113.43Lo-Carbon VA100/SELV XTDOM(Shutter/Timer)Integral electronic adjustable overrun timer (5-30minutes). Indication light. 2 speed options.Model Stock Ref £ TradeXT 443162 90.84SELV XT 459050 138.94Lo-Carbon VA100/SELV LHTPDOM(Integral Humidity Sensor/Pullcord)Complete with integral humidity control withpullcord override. Indication light which operateson the manual override only. 2 speed options.Model Stock Ref £ TradeLHTP 443163 158.19SELV LHTP 441616 182.47Lo-Carbon VA100/SELV XHTPDOM(Shutter/Integral Humidity Sensor/Pullcord)Complete with integral humidity control withpullcord override. Indication light which operateson the manual override only. IPX4 rated. 2speed options.Model Stock Ref £ TradeXHTP 443164 168.65SELV XHTP 436064 194.07Wall KitDOMFixing hole diameter 105mmØStock Ref£ Trade254102 (White) 17.42254100 (Brown) 17.42Window KitDOMFixing hole diameter 117mmØStock Ref£ Trade254101 17.4210 T: 0844 856 0590


Lo-Carbon Residential FansDimensions (mm)Panel Wall Window200A B C DØ E FBathroom/Toilet 155 44 68 98 32 89AADØSELV Transformer (W x H x D) 87 x 87 x 33Weight 1kgABC56 200 E FPerformanceExtract Performance - FID Sound dB(A) SFPArea Models m 3 /h l/s Watts @ 3m @ 0PaToilet Lo-Carbon VA100/SELV LP/XP/LHTP/XHTP/LT/XT 60 17 3.4 32 0.20Bathrooms Lo-Carbon VA100/SELV LP/XP/LHTP/XHTP/LT/XT 74 21 6.1 36 9W: www.vent-axia.com 11


Lo-Carbon Residential FansDimensions (mm)PanelWall KitA BØ C D E F160 99 115 132 200 32B ØSELV Transformer (WXHXD) 87X87X33Weight 0.6kgAØCDPerformanceExtract Performance - FID Sound dB(A) SFPArea Model m 3 /h l/s Watts @ 3m @ 0PaToilet Lo-Carbon Silhouette 100 B/T/H/SVB/SVT/SVH 60 17 3.4 34 0.21Bathrooms Lo-Carbon Silhouette 100 B/T/H/SVB/SVT/SVH 105 29 8.7 38 0.30* For window mounting shutter cannot be used and must be removedW: www.vent-axia.com 13


Lo-CarbonSolo Plus/SELVCentrifugal Bathroom/Toilet FanFeatures & Benefits Lo-Carbon Solo Plus SELV is suitable forinstallation over or within reach of ashower or bath Reduces the home’s carbon footprint Up to 70% energy saving Integral Lo-Carbon power supply Built-in washable filter feature Meets current Building Regulations ApprovedDocuments F & L IPX4 rated - IPX7 rated (SELV) Flush or surface mountable Adjustable rear or side exit spigot Extremely low sound levels 5 Year Motor Guarantee Suitable for wall, ceiling and panel mounting SELV Models - Supplied with a remotetransformerLong Life <strong>Vent</strong>ilationThe Lo-Carbon Solo Plus range from <strong>Vent</strong>-<strong>Axia</strong> hasbeen specially designed for through the wall andducted applications, suitable for internal bathrooms,toilets and other small rooms. Finished in white,the Lo-Carbon Solo Plus can be flush or surfacemounted, with a 2-position 100mm circular spigotfor rear entry or connecting to a vertical ductingsystem. The powerful centrifugal impeller allowsinstallations using 100mm ducting in straight runs upto 50m, whilst still achieving 15l/s as required byBuilding Regulations Approved Document F.Continuous running products, such as the Solo Plus,installed in all wet areas of a dwelling are classedas a wholehouse ventilation system and thereforeonly needs to move the amount of air as laid downin table 1.1b of Building Regulations ApprovedDocument F.The Lo-Carbon Solo Plus has an adjustable boostspeed which is set at installation variable between12-25l/s for boost/override operation to meetBuilding Regulations thus ensuring minimum energyusage and low sound levels. All models have anoptional speed for constant trickle ventilation(12l/s), selectable at installation. Depending on themodel, the fan will switch from trickle (if selected)to boost via the pullcord/light switch/humiditysensor/PIR.All models can be wall, panel or ceiling mountedand can be connected to either circular, rectangularor <strong>Vent</strong>-<strong>Axia</strong>’s flat ducting. Enclosure of the electricalcomponents is manufactured from flame retardantgrade material.Safety Extra Low Voltage Fan (SELV)Designed for areas where a fan has to be fittedover or within Zone 1 in a room containing a fixedbath or shower according to IEE wiring regulations(BS 7671), the Lo-Carbon Solo Plus SELV fan canbe safely installed within the spray area. The fanis rated IPX7. Control is by mains safety isolatingtransformer unit with 24V DC SELV output, whichis sited away from any source of spray and out ofreach of a person using a fixed bath or shower.Controller Supply voltage 220-240V/1/50Hz.Output to fan SELV 24V DC.ModelsLo-Carbon Solo Plus/SELV PDOM(Pullcord)Flush or surface mountable. Control by Pullcord. 2Speed. Constant trickle option. Adjustable boost.In-built Lo-Carbon controller.Model Stock Ref £ TradeP 427481 122.06SELV P 427485 129.46Lo-Carbon Solo Plus/SELV TDOM(Timer)Flush or surface mountable. Control by room light orswitch. 2 Speed. Constant trickle option. Adjustableboost. Adjustable timer overrun. Delay on timer.In-built Lo-Carbon controller.Model Stock Ref £ TradeT 427482 139.85SELV T 427486 147.95Lo-Carbon Solo Plus/SELV HTDOM(Humidistat-Timer)Flush or surface mountable. Humidity controlledfan with override pullcord. Constant trickle option.Adjustable boost. Adjustable timer overrun. Delayon timer. Adjustable humidity sensor. In-builtLo-Carbon controller. Available from early 2013:Hour Run Meter as standard on all Lo-carbonhumidity controlled Solo Plus fans.Model Stock Ref £ TradeHT 427483 197.26SELV HT 427487 203.44Lo-Carbon Solo Plus/SELV TMDOM(Timer/PIR)Flush or surface mountable. Control by integralPIR detector. 2 Speed. Constant trickle option.Adjustable boost. In-built Lo-Carbon controller.Model Stock Ref £ TradeTM 427484 277.41SELV TM 427488 283.57Lo-Carbon Solo Plus BezelDOMUsed when flush mounting - reduces the need tomake good.Stock Ref£ Trade437078 9.25Wall KitDOMStock Ref£ Trade254102 (White) 17.42254100 (Brown) 17.4216 T: 0844 856 0590


Lo-Carbon Residential FansDimensions (mm)BCDEØFGJKA B C D EØ261 221 107 54.5 98F G H I JA64 61 37 98 70SELV Transformer: (W x H x D) 147 x 88 x 50.Weight 2.2kg, SELV Weight 2.7kg.LPerformance Curve10080Pressure Pa604023123TrickleMin BoostMax Boost201Performance Guide0 10 20 30 40 50 60 70 80 90 100Volume Flow m³/hrExtract Performance m 3 /h (l/s) - FID Watts Sound dB(A) @ 3mModel Trickle Min Boost Max Boost Trickle Min Boost Max Boost Trickle Max Boost SFP @ 0PaLo-Carbon Solo Plus P/T/HT/TM 43 (12) 69 (19) 90 (25) 4 8.6 15 24.6 46.4 0.43Lo-Carbon Solo Plus SELV P/T/HT/TM 43 (12) 69 (19) 90 (25) 5 9.6 16 24.6 46.4 0.50Tested at 240VAC @ 50HzW: www.vent-axia.com 17


Lo-Carbon Residential FansLo-CarbonMiniventDucted Bath/Shower Fan KitFeatures & Benefits Complete kit supplied Meets Building Regulations ApprovedDocument F & L requirements for toiletsand bathrooms at max 1.5m of ductingand 1x 90˚ bend Adjustable timer version available 5 Year Motor Guarantee 1 of 2 speeds selectable at installationPowerful Lo-Carbon In-Line Fan KitThe <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon Minivent ducted bath/shower kit includes all the components necessaryto install a ducted 100mm system. This simplifiesfitting of an efficient ventilation system to smallrooms including bath, shower rooms and toilets. It isespecially suitable for en-suite bathrooms.Lo-Carbon MiniventShower Kit installedWhen installed, the fan kit has ample performanceto meet the Building Regulations requirements fortoilets and bathrooms. The timer version should beused for internal rooms.The kit consists of a Lo-Carbon Minivent In-Linefan, a white ceiling grille and spigot, 3 metres offlexible duct and an external louvre for soffit or wallmounting. The duct should be cut to the requiredlength and the bend radius kept to a maximum toprovide the best fan performance.Enclosed terminal compartment, Class 2 appliance.Supply voltage 220-240/1/50Hz.ModelsLo-Carbon Minivent Shower FanDOM(Basic)Comprises - high output tube fan, 3 metres offlexible duct, ceiling inlet grille and spigot, soffit/wall outlet grille.Stock Ref£ Trade441421 50.14Lo-Carbon Minivent Shower FanDOM(Timer)Comprises - high output tube fan, 3 metres offlexible duct, ceiling inlet grille and spigot, soffit/wall outlet grille.Stock Ref£ Trade441422 60.42Dimensions (mm)Transformer (W x H x D) 87 x 87 x 33A B C DØ E130 155 90 48 27ABRear ViewCDPerformanceExtract performance - FIDSound dB(A)Model m 3 /h l/s Watts @ 3m SFP @ 0PaLo-Carbon Minivent B/T 110 31 6.5 23 0.21ESide ViewInternal/External Grille Dimensions170x170mm18 T: 0844 856 0590


Lo-Carbon<strong>Vent</strong>-A-LightDucted Bath/Shower Fan KitLo-Carbon Residential FansFeatures & Benefits Suitable for shower enclosure andwet areas Provides simultaneous fanand light operation Meets current Building RegulationsApproved Document F & L 1 of 2 speeds selectable at installation Double insulated fan Light assembly Class III 5 Year Motor Guarantee Supplied with white and chrome bezels100mm Lo-Carbon axial in-line shower fan and lightkit. Provides simultaneous fan and light operation.Suitable for shower enclosures and wet areas.Available with both a white and chrome bezel onlight assembly. The light assembly can be held inplace using fixing clips or screws.Typical SpecificationCE marked in accordance with all the relevant EECHarmonised Directives.Fan double insulated and the motor is fitted withThermal Protection. Light assembly class III.ModelsLo-Carbon <strong>Vent</strong>-A-Light Fan and Light Kit DOM(Standard )100mm axial in-line shower fan and light kit. Includesfan, 3m flexible ducting, white grille, light transformerand light assembly with white and chrome bezels.Stock Ref£ Trade441423 104.80Lo-Carbon <strong>Vent</strong>-A-Light Fan Light Kit DOM(Timer)100mm axial in-line shower fan and light kit. Fanhas electronic overrun timer adjustable from 5 to 30minutes. The factory setting is 15 minutes. Includesfan, 3m flexible ducting, white grille, light transformerand light assembly with white and chrome bezels.Stock Ref£ Trade441424 117.14Dimensions (mm)AØ BØ C D155 100 65 14Hole Sizes: Ø115mm when using screws.Ø130mm with fixing clipsLight Transformer Dimensions(W x H x D) 101 X 20 X 39Front ViewSide ViewBØAØPerformanceExtract performance - FIDSound dB(A)Model m 3 /h l/s Fan Watts @ 3m SFP @ 0PaLo-Carbon <strong>Vent</strong>-A-Light B/T 110 31 6.5 23 0.21Tested at 240V 50HzDCInternal/External Grille Dimensions 170x170mmFan Transformer (W x H x D) 87 x 87 x 33W: www.vent-axia.com 19


Lo-CarbonQuadra®/SELV‘One Fan fits all’ Centrifugal FanFeatures & Benefits Single fan for use in toilets, bathrooms, utilityrooms and kitchens Meets current Building RegulationsApproved Document F & L for intermittent orcontinuous use Guaranteed installed performance SAP Appendix Q eligible - Low SFP on SAPQ 0.38 100mm circular spigot for easy installationand replacement of any existing fan Filterless technology and maintenance free Lo-Carbon motors offering 90% energysavings and long life Motor cassette cartridge for simplereplacement Suitable for flush or surface mounting 5 Year Motor Guarantee IPX4 rated - IPX7 rated (SELV) Suitable for wall, ceiling and panel mounting TP and HTP main and SELV version alsoincludes an optional dataloggerLo-Carbon Quadra SELVThe Lo-Carbon Quadra SELV has been designed tomeet building requirements where there is a need to fitin Zone 1 containing a fixed bath or shower accordingto IEE wiring regulations. The Lo-Carbon Quadra SELVcan be safely installed within the spray area with the24VDC Safety Isolating Power Supply situated awayfrom the spray zone and out of reach of the personusing the facility.<strong>Vent</strong>ilation for any roomThe Lo-Carbon Quadra offers a single fan suitablefor surface or flush mounting. Low speed selectablebetween 6, 9 and 12l/s and high between 15, 30 and60l/s all with through the wall or two ducted selectionsto ensure installed performance is met.DiscreteWith discrete aesthetics and low noise levels due to anaccurately balanced impeller, it is also one of the mostunobtrusive centrifugal kitchen fans available. The frontcover design also provides no area for dirt to build upso it stays looking better for longer.ModelsLo-Carbon Quadra TP/SVTPDOM(Timer/Pullcord)Dual speed: continuous running or intermittent to highspeed. High speed via pullcord (On/Off) or switch live(with overrun timer).Model Stock Ref £ TradeTP 439251 197.74SVTP 442865 227.39TP Datalogger 443811 228.76SVTP Datalogger 446269 258.41Lo-Carbon Quadra HTP/SVHTPDOM(Humidistat/Timer/Pullcord)Dual speed: continuous running or intermittent to highspeed. High speed via integral pullcord (On/Off),integral adjustable humidity sensor or switch live (withoverrun timer). Available from early 2013: Hour RunMeter as standard on all Lo-carbon humidity controlledQuadra fans.Model Stock Ref £ TradeHTP 439181 232.05SVHTP 442866 266.18HTP Datalogger 443812 263.06SVHTP Datalogger 446270 297.19SAP Appendix Q PerformanceSystems With Rigid Ductwork Installation OnlySystems With Flexible Or Mixed Ductwork Installation OnlyLo-Carbon Quadra TM/SVTMDOM(Timer/PIR)Dual speed: continuous running or intermittent to highspeed. High speed via integral PIR sensor or switch live(both with overrun timer).Model Stock Ref £ TradeTM 439253 273.34SVTM 442867 314.05Flush mounting KitDOMStock Ref£ Trade439256 11.57Filter (optional)DOMStock Ref£ Trade439927 5.79Decoration FrameGENStock Ref£ Trade442551 16.40Wall KitDOMStock Ref£ Trade254102 (White) 17.42254100 (Brown) 17.42Flow Rate- WindCondition (l/s)UnitConfiguration LocationFan SpeedSetting Flow Rate (L/s)Specific FanPower (W/l/s)In Room Kitchen 15 l/s 15.8 14.4 0.41 9In Room Wet Room 9 l/s 14.6 13.2 0.61 10Through Wall Kitchen 15 l/s 21.4 19.4 0.38 9Through Wall Wet Room 9 l/s 19.5 17.6 0.58 10Flow Rate- WindCondition (l/s)% ReductionOf Total FlowRate% ReductionOf Total FlowRateUnitConfiguration LocationFan SpeedSetting Flow Rate (L/s)Specific FanPower (W/l/s)In Room Kitchen 15 l/s 13.7 12.4 0.41 9In Room Wet Room 9 l/s 12.9 11.6 0.63 10Through Wall Kitchen 15 l/s 21.4 19.4 0.38 9Through Wall Wet Room 9 l/s 19.5 17.6 0.58 1020 T: 0844 856 0590


BELo-Carbon Residential FansWINNER2011Winners of the Energy Efficiency Initiative 2011 Awardwith our Lo-Carbon Continuous <strong>Vent</strong>ilation <strong>Product</strong> Range.ELIGIBLE FORSAP APPENDIX QDimensions (mm)Front ViewSide ViewDFHRear ViewGA B C D E F G H230 260 112 67 98 27 58 79ACPerformance Curve2030025015Pressure (Pa)1023Pressure (Pa)20015061100550500 5 10 1520Volume (l/s)123Quadra 6 l/sQuadra 9 l/sQuadra 12 l/s040 10 20 30 40 50 60 70Volume (l/s)456Quadra 15 l/sQuadra 30 l/sQuadra 60 l/sPerformance GuideExtract PerformancePowerHigh Low High Low Sound dB(A) @ 3mModel m 3 /h l/s m 3 /h l/s Watts Watts High LowLo-Carbon Quadra/SELV TP/ HTP/ TM 223 63 22 6 38 3.8 50 20*Tested in through the wall installationW: www.vent-axia.com 21


Lo-Carbon Residential FansLo-CarbonSilhouette 125Bathroom/Toilet FansFeatures & Benefits Models Basic/Timer/Humidity- Installation options Low power consumption- Lower running costs Quiet running Fully opening and closing shutters- Improved insulation 1 of 2 speeds selectable at installation Non transparent shutters- Enhanced privacy Ball bearing motors for vertical orhorizontal application Unique humidity sensor track- Improved response 5 Year Motor Guarantee IPX4 rated Suitable for wall, ceiling andpanel mountingSlimline Bathroom <strong>Vent</strong>ilationWith a slim profile of only 18mm, Silhouette blendsin with the wall surface to provide an unobtrusiveinstallation. Silhouette has a FID performance upto 160m 3 /h. Silhouette can be ceiling/panelmounted and connected to an appropriate duct runto the outside.ModelsLo-Carbon Silhouette 125BDOM125mm bathroom/toilet fan with indicator light andback draught shutter.Model Stock Ref £ Trade125B 446483 96.16Lo-Carbon Silhouette 125TDOM(Timer)125mm bathroom/toilet fan with integral adjustableelectronic overrun timer (5-30 minutes), indicatorlight which operates on manual override only, andback draught shutter.Model Stock Ref £ Trade125T 446484 108.50Lo-Carbon Silhouette 125HTDOM(Timer/Humidistat)125mm bathroom/toilet fan with integral adjustableauto humidity sensor from 60-90% RH and overruntimer, indicator light which operates on manualoverride only, and back draught shutter. Availablefrom early 2013: Hour Run Meter as standard on allLo-carbon humidity controlled Silhouette fans.Model Stock Ref £ Trade125HT 446485 182.01Wall KitGENStock Ref£ Trade455226 19.7418mm actual profileDimensionsPanelBack draught preventionvanes fitted on dischargeA B C D187 125 131 149AØB ØCDPerformanceExtract Performance Sound dB(A)Model m 3 /h l/s Watts @ 3mLo-Carbon Silhouette 125B/T/HT 160 45 7 3722 T: 0844 856 0590


Lo-Carbon Residential FansLo-CarbonVA150<strong>Axia</strong>l Kitchen & UtilityRoom FansFeatures & Benefits Reduces the home’s carbon footprint Long life Lo-Carbon motor lasts 5 timeslonger than conventional motors Up to 60% energy saving Meets current Building RegulationsApproved Document F & L when installed IP44 rated Low sound levels 5 Year Motor Guarantee Suitable for wall, ceiling, window andpanel mounting Fitted with a motorised shutter 1 of 2 speeds selectable at installationLong Life <strong>Vent</strong>ilation<strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon VA150 fans feature Lo-Carbonlong life DC energy saving motors that last 5 timeslonger than conventional motors, whilst deliveringup to 60% energy savings. The extended life ofLo-Carbon fans is due to the use of a new generationof high quality electronically controlled ball-bearingmotors especially developed for this range. Themotors are perfectly designed for the wet conditionsof utility rooms and kitchens, extracting stale,moisture-laden air quietly and efficiently.ShuttersThe <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon VA150 range is fitted witha motorised shutter mechanism that uses no extrapower in operation or off.PerformanceInstallationThe Lo-Carbon VA150 range is suitable forinstallation in panels, walls or windows using the kitsavailable. Lo-Carbon fans are quick and simple to fitusing reversible grommets and easy-wire terminals,and are suitable for wall or ceiling mounting atany angle.150mm telescopic wall kits are available with awhite or brown outside grille. The kit is supplied witha telescopic wall sleeve to fit walls 225–360mmthick. Hole diameter 152mm.Window fitting kits are available for use with allLo-Carbon 150mm models through single ordouble glazed windows up to 40mm thick. Holediameter 152mm.ModelsLo-Carbon VA150PDOM(Shutter/Pullcord)Ultra long life DC energy saving motor. Fittedwith a motorised shutter. Controlled via pullcordOn/Off switch.Stock Ref£ Trade459123 166.16Lo-Carbon VA150TDOM(Shutter/Timer)Ultra long life DC energy saving motor. Fitted witha motorised shutter. Controlled via integral powersupply with electronic adjustable overrun timer(5-30 minutes).Stock Ref£ Trade459124 204.93Extract PerformanceSounddB(A)SFP @Setting Model m 3 /h l/s @ 3m Watts 0PaUtility Setting Lo-Carbon VA150P/T/HP 160 46 33 7.5 0.16Kitchen Setting Lo-Carbon VA150P/T/HP 230 64 36 11.5 0.18Lo-Carbon VA150HPDOM(Shutter/Humidistat)Ultra long life DC energy saving motor. Fitted witha motorised shutter. Controlled via integral powersupply with pullcord override switch and adjustablehumidity sensor (60-95% RH).Stock Ref£ Trade459125 253.17Wall KitDOMStock Ref£ Trade140902 (White) 19.96140903 (Brown) 19.96Window KitDOMStock Ref£ Trade140901 19.96Dimensions (mm)A B C DØ E216 224 80 146 60Weight 1.2kgBAAECDØW: www.vent-axia.com 23


Lo-Carbon Residential FansLo-CarbonSilhouette® 150<strong>Axia</strong>l Kitchen FansFeatures & Benefits Stylish ultra low profile grille Downstream airflow guide vanes forimproved pressure development Ball bearing motors for vertical orhorizontal application Wall kit design meets Building RegulationsApproved Document F requirements 5 Year Motor Guarantee 1 of 2 speeds selectable at installation IPX4 rated Low Specific Fan Power Suitable for wall, ceiling and panelmountingSlimline Lo-Carbon Kitchen <strong>Vent</strong>ilationThe Lo-Carbon Silhouette range is designedfor modern living. With a profile of only 19mmon the kitchen models, Lo-Carbon Silhouetteblends in with the wall surface to provide anunobtrusive installation.Mounted in the centre of the fan, beneath the ultraslim profile grille, are the electronics, incorporatinga humidistat for detecting a change in internalhumidity or an overrun timer option that is adjustablebetween 5 and 30 minutes.FID performance of 67l/s, double insulated. Powerconsumption only 8.2 watts.ModelsLo-Carbon Silhouette 150BDOM150mm kitchen fan with indicator light and backdraught shutter.Stock Ref£ Trade441628 96.54Lo-Carbon Silhouette 150TDOM(Timer)150mm kitchen fan with integral adjustableelectronic overrun timer (5-30 minutes), indicatorlight which operates on manual override only andspring back draught shutter.Stock Ref£ Trade441629 108.50Lo-Carbon Silhouette 150HTDOM(Humidistat/Timer)150mm with integral adjustable auto humiditysensor from 60-90% RH and overrun timer, indicatorlight which operates on manual override only andback draught shutter. Available from early 2013:Hour Run Meter as standard on all Lo-carbonhumidity controlled Silhouette fans.Stock Ref£ Trade441630 191.85Wall KitDOMStock Ref£ Trade140902 (White) 19.96140903 (Brown) 19.96Dimensions (mm)A BØ C D G H223 147 130 19 220 37Weight 1.75kgABØCDAPerformanceExtract Performance Sound dB(A) SFP @Setting Model m 3 /h l/s Watts @ 3m 0PaUtility Setting Lo-Carbon Silhouette 150B/T/HT 165 46 5 35 0.15Kitchen Setting Lo-Carbon Silhouette 150B/T/HT 241 67 8.2 43 0.15Fixing hole diameter 152mmØ (when wall kit used)24 T: 0844 856 0590


W: www.vent-axia.com 25


Residential FansSilent FanThe <strong>Vent</strong>-<strong>Axia</strong> Silent Fan, the quietest bathroomextract fan on the market.The stylish design and silent performance meansit is the ultimate in discrete bathroom ventilation.This means your bathroom can now be therelaxing environment you always wanted.Meets current Building Regulations ApprovedDocuments F & L.RangeThe UK’s mostcomprehensive rangeof traditional fans fortoilets, bathrooms, utilityrooms and kitchens.26 T: 0844 856 0590


W: www.vent-axia.com 27


Residential FansVA100®<strong>Axia</strong>l Bathroom/Toilet FansFeatures & Benefits Indication light Panel, ceiling, window or wall mounting Available with electric shutter Sensors and auto mode controllers saveenergy by switching the ventilation unitson only when needed and when the roomis occupied Adjustable overrun time option available(5-30 minutes) Meets current Building Regulations ApprovedDocument F IPX4 ratedBathroom and Toilet <strong>Vent</strong>ilationThe VA100 range from <strong>Vent</strong>-<strong>Axia</strong> is designedfor domestic bathrooms and toilets. Available aswindow, wall or panel mounted models. A rangeof fans with options of shutter, timer or humiditycontrolled versions.Suitable for ambient temperatures up to +40°C,the unit is fitted with Standard Thermal OverloadProtection (S.T.O.P).ModelsVA100LPDOMBathroom extract fan pullcord and indication light.Stock Ref£Trade251110 32.03VA100LT(Timer)DOMBathroom and toilet fan with adjustable electronicoverrun timer and indication light which operateson the override only.Stock Ref£Trade251210 45.09VA100XPDOM(Shutter)Bathroom fan with thermo-electric shutter, pullcordand indication light.Stock Ref£Trade251310 53.39VA100XT(Timer/Shutter)DOMBathroom fan with adjustable electronic overruntimer, thermo-electric shutter and indication lightwhich operates on override only.Stock Ref£Trade251410 74.66VA100LHP(Humidity)DOMBathroom fan with pre-settable integral autohumidity control, pullcord, and indication light whichoperates on manual override only.Stock Ref£Trade251610 101.82VA100XHP(Shutter/Humidity)DOMBathroom fan with pre-settable integral auto humiditycontrol, thermo-electric shutter, pullcord, andindication light which operates on manual overrideonly.Stock Ref£Trade251710 130.74VA100XHT(Shutter/Humidity/Timer)DOMBathroom fan with pre-settable integral autohumidity control and adjustable electronic overruntimer, thermo-electric shutter and indication light.Stock Ref£Trade251510 134.35Performance - Panel ModelsExtractperformanceSounddB(A)Model m 3 /h l/s Watts @ 3m ShutterVA100LP 107 30 13 36VA100LT 107 30 15 36VA100XP 107 30 15 36 ThermoVA100XT 107 30 18 36 ThermoVA100LHP 107 30 16 36VA100XHP 107 30 18 36 ThermoVA100XHT 107 30 18 36 ThermoDimensions (mm)A B C D E F G155 44 48 98 32 89 200Weight 0.55kgPanelAFixing hole diameter 105mmØWindowAFixing hole diameter 105mmØAAAEBWindow KitDOMStock Ref£Trade254101 17.42WallFixing hole diameter 117mmØWall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42FCDØ28 T: 0844 856 0590


Residential FansVA100® SELV 12<strong>Axia</strong>l Bathroom/Toilet FansFeatures & Benefits Designed for safe use in the spray area ofa bathroom or shower and within reach ofa person using a bath or shower Available with electric shutter Fan IPX7 rated SELV Transformer to BS EN 60 742 Window, ceiling, wall or panel mounting Indication light Meets current Building RegulationsApproved Document FSafety Extra Low Voltage Fan (SELV)A range of fans with optional shutter, timer andhumidity controlled versions to match applicationrequirements precisely. Designed in a clean whitefinish and suitable for ambient temperatures upto +40°C the unit is fitted with Standard ThermalOverload Protection (S.T.O.P.).Designed for areas where a fan has to be fittedover or within Zone 1 in a room containing a fixedbath or shower according to IEE wiring regulations(BS 7671), the VA100 SELV fan can be safelyinstalled within the spray area. The fan is rated IPX7.Control is by mains safety isolating transformer unitwith SELV output, which is sited away from anysource of spray and out of reach of a person usinga fixed bath or shower.ModelsVA100SVL 12DOMIPX7 rated fan with indication light, complete withremote wall mounted transformer.Stock Ref£Trade258110 90.02VA100SVX 12(Shutter)DOMIPX7 rated fan with thermo-electric shutter andindication light, complete with remote wall mountedtransformer.Stock Ref£ Trade258310 101.04VA100SVXP 12(Shutter/Pullcord)DOMIPX7 rated fan with thermo-electric shutter andindication light, complete with remote wall mountedtransformer. Boost via pullcord.Stock Ref£Trade258310BD025 113.61VA100SVXT12(Shutter/Timer)DOMIPX7 rated fan with thermo-electric shutter andindication light which operates on override only.Complete with remote mounted transformer withintegral adjustable overrun timer.Stock Ref£Trade258410 124.92VA100SVLHP 12(Humidity/Pullcord)DOMIPX7 rated fan complete with remote wall mountedtransformer. Integral Humidity Sensor with pullcordoverride. Indication light which operates on manualoverride only.Stock Ref£Trade258112 165.36VA100SVXH 12(Humidistat/Pullcord)DOMIPX7 rated fan with thermo-electric shutter completewith remote wall mounted transformer. IntegralHumidity Sensor with pullcord override. Indicationlight which operates on manual override only.Stock Ref£Trade258312 176.35VA100SVXHT 12(Shutter/Humidistat)DOMIPX7 rated fan with integral humidistat/timer, andthermo-electric shutter. Remote wall-mountedtransformer with switch live override. Indication lightwhich operates on manual override only.Stock Ref£Trade258512 187.02Dimensions (mm)A B C D E F G155 44 48 98 32 89 200Weight 0.55kgTransformer (WxHxD) 147x86x65PanelAFixing hole diameter 105mmØWindowAAAAEBFixing hole diameter 105mmØWindow KitDOMStock Ref£Trade254101 17.42WallFixing hole diameter 117mmØWall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Performance Extract performance Sound dB(A)Model m 3 /h l/s Watts @ 3m ShutterVA100SVL 75 21 16 36VA100SVX 75 21 18 36 ThermoVA100SVXT/XHP/XHT/XP 75 21 20 36 ThermoVA100SVLHP 75 21 18 36FCDØW: www.vent-axia.com 29


Residential FansSilhouette® 100<strong>Axia</strong>l Bathroom/Toilet FansFeatures & Benefits 17mm stylish ultra low profile grille Downstream airflow guide vanes forimproved pressure development Designed for vertical or horizontalapplication Indication light Fan IPX4 rated Suitable for wall, ceiling, panel andwindow mounting Meets current Building Regulations ApprovedDocument FSlimline Bathroom <strong>Vent</strong>ilationWith a slim profile of only 17mm, Silhouette blendsin with the wall surface to provide an unobtrusiveinstallation. Silhouette has a FID performance of21 l/s. Silhouette can be ceiling/panel mountedand connected to an appropriate duct run tothe outside.17mm actual profileModelsSilhouette 100BDOMSingle speed 100mm bathroom/toilet fan withindication light and back draught shutter.Stock Ref£Trade454055 37.51Silhouette 100T(Timer)DOMSingle speed 100mm bathroom/toilet fan withintegral adjustable electronic overrun timer (5-30minutes), indication light and back draught shutter.Stock Ref£Trade454056 51.10Silhouette 100H(Humidity)DOMSingle speed 100mm bathroom/toilet fan withintegral adjustable auto humidity sensor from 60-90% RH, indication light and back draught shutter.Stock Ref£Trade454057 94.43Silhouette 100TM(PIR/Timer)DOMSingle speed 100mm bathroom/toilet fan. IntegralPIR operated model, (presence detector) withadjustable electronic overrun timer (5-30 minutes)indication light and back draught shutter.Stock Ref£Trade454058 82.67Dimensions (mm)A BØ C D E F160 100 80 97 200 32Weight 0.6kgPanelWallAØB ØFixing hole diameter 117mmØCDWall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Window kitStock ref£Trade442947 18.84Back draught prevention vanesfitted on dischargePerformance Extract Performance - FID Sound dB(A)Model m 3 /h l/s Watts @ 3mSilhouette 100B/T/H/TM 75 21 14 3830 T: 0844 856 0590


Residential FansSilhouette®100 SELV<strong>Axia</strong>l Bathroom/Toilet FansFeatures & Benefits 17mm stylish ultra low profile grille Downstream airflow guide vanes forimproved pressure development Designed for vertical or horizontalapplication Fan IPX7 rated SELV transformer to BSEN 60742 Indication light Suitable for wall, ceiling, panel andwindow mounting Meets current Building Regulations ApprovedDocument FSlimline Bathroom <strong>Vent</strong>ilationWith a slim profile of only 17mm, Silhouette blendsin with the wall surface to provide an unobtrusiveinstallation. Silhouette has a FID performance of21 l/s. Silhouette can be ceiling/panel mountedand connected to an appropriate duct run tothe outside.ModelsSilhouette 100SVBDOMSingle speed 100mm bathroom/toilet fan withindication light and back draught shutter.Stock Ref£Trade439974 75.90Silhouette 100SVT(Timer)DOMSingle speed 100mm bathroom/toilet fan withintegral adjustable electronic overrun timer (5-30minutes), indication light and back draught shutter.Stock Ref£Trade439975 94.51Silhouette 100SVH(Humidity)DOMSingle speed 100mm bathroom/toilet fan withintegral adjustable auto humidity sensor from 60-90% RH, indication light and back draught shutter.Stock Ref£Trade439976 133.18Dimensions (mm)A BØ C D E F160 100 80 97 200 32Transformer (W X H X D) 147 X 86 X 65Weight 0.6kgPanelWallB ØCAØD17mm actual profileFixing hole diameter 117mmWall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Back draught prevention vanesfitted on dischargePerformance Extract Performance - FID Sound dB(A)Model m 3 /h l/s Watts @ 3mSilhouette 100SVB/SVT/SVH 75 21 18 38W: www.vent-axia.com 31


Residential FansSilent Fan 100<strong>Axia</strong>l Bathroom/Toilet FansFeatures & Benefits Silent intermittent bathroom fan with twospeeds selectable at installation Stylish discrete design Back draught shutters included High efficiency motor 2 year guarantee IP44 rated Standard thermal overload protection onmotor Suitable for wall, ceiling, window andpanel mounting Meets current Building Regulations ApprovedDocument F and LSilent 100 <strong>Axia</strong>l Bathroom/Toilet FansThe quietest bathroom fan on the market. TheVASF100 provides stylish and silent ventilationwithout compromising on performance.ModelsVASF100BDOM1 of 2 speeds selectable at installation. 100mmbathroom / toilet fan with back draught shutter.Stock Ref£Trade446658 48.21VASF100T(Timer)DOM1 of 2 speeds selectable at installation. 100mmbathroom / toilet fan with back draught shutterand overrun timer adjustable between 5 and30 minutes.Stock Ref£Trade446659 60.42Window KitDOMStock Ref£Trade442947 18.84Wall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Dimensions (mm)A B C D E FØ159 159 123 43 80 100Weight 0.7kgABCFDEBack draught prevention vanesfitted on dischargePerformanceModel l/s Watts Sound dB(A) @ 3mVASF100 - low speed 15 4.3 16VASF100- high speed 21 6.8 2832 T: 0844 856 0590


Residential FansSilhouette® 125<strong>Axia</strong>l Bathroom/Toilet FansFeatures & Benefits 18mm stylish ultra low profile grille Downstream airflow guide vanes forimproved pressure development Designed for vertical or horizontalapplication Modern aesthetic with indication light Fan IPX4 rated Suitable for wall, ceiling and panelmountingSlimline Bathroom <strong>Vent</strong>ilationWith a slim profile of only 18mm, Silhouette blendsin with the wall surface to provide an unobtrusiveinstallation. Silhouette has a FID performance of160m 3 /h. Silhouette can be wall, ceiling or panelmounted and connected to an appropriate duct runto the outside.ModelsSilhouette 125BDOMSingle speed 125mm, bathroom/toilet fan withindication light and back draught shutter.Stock Ref£ Trade445161 73.49Silhouette 125T(Timer)DOMSingle speed 125mm bathroom/toilet fan withintegral adjustable electronic overrun timer (5-30minutes), indication light and back draught shutter.Stock Ref£Trade445162 85.92Silhouette 125H(Humidistat)DOMSingle speed 125mm bathroom/toilet fan withintegral adjustable auto humidity sensor from 60-90% RH, indication light and back draught shutter.Stock Ref£Trade445163 139.26Dimensions (mm)A B C D187 125 131 149PanelB ØCAØDGENWall KitStock Ref£Trade455226 19.7418mm actual profilePerformanceExtract Performance - FIDSound dB(A)Model m 3 /h l/s Watts @ 3mSilhouette 125B/T/H 160 45 20 40Back draught prevention vanesfitted on dischargeW: www.vent-axia.com 33


Residential FansLuminAir®Fan & LightCombination UnitFeatures & Benefits The original fan and light combination IPX7 rated Suitable for shower enclosures and wetareas - can be used within reach of aperson using a bath or shower Safety extra low voltage (SELV) Easy installation White, Gold and Chrome bezels availableSafety Extra Low VoltageThe revolutionary <strong>Vent</strong>-<strong>Axia</strong> LuminAir Safety ExtraLow Voltage fan and light in a single ceilingmounted fitting.The IPX7 unit is installed directly over a showerin complete safety. <strong>Vent</strong>-<strong>Axia</strong> LuminAir extractsmoisture and humidity at source, preventingdamaging condensation from spreading. At thesame time it bathes the shower enclosure in a richsoft light - bringing any dark shower to life. Ideal forall types of bathroom and shower applications, andis particularly suitable for bedsit and en-suite showerinstallations.Designed for mounting in a wide variety of ceilingthicknesses. The safety isolating transformer toBS EN 60742 is mounted in a purpose madeenclosure that can be wall mounted or sited inthe loft, and is designed to accept mini trunking(LuminAir L transformer - IP20 - loft mounted).LuminAir has a 20 Watt 40˚ spread, preformedDichroic Multi-Mirror lamp, to give a pool of softwarm light. The lamp has a long life and is simpleto change.Seperate lighting transformer also supplied.ModelsLuminAir L(Switch Live)DOMProvides simultaneous fan and light operation fromthe bathroom light switch.Stock Ref£Trade188110 123.57LuminAir T(Timer)DOMSwitches the fan On with the light. When thelight is switched Off, the fan continues to run foran adjustable set period to meet the BuildingRegulations for internal bathrooms.Stock Ref£Trade188210 176.19LuminAir H(Humidistat)DOMCombines a light activated by the bathroom lightswitch and an Ecotronic Humidity Sensor whichwill switch the fan On whenever the humidity levelwarrants.Stock Ref£Trade188610 200.20Supply to the LuminAir transformer 220-240V/1/50Hz.Output to LuminAir 12V SELV/1/50Hz. Safetyisolating transformers conform to BS EN 60742.Optional BezelsDOMStock Ref£Trade452044 - Chrome 15.54452045 - Gold 32.82LuminAir <strong>Vent</strong> LightDOMSafety Extra Low Voltage Duct Air InletLuminAir <strong>Vent</strong> Light is for upgrading existing extractsystems or to provide multiple extract points to acentral fan. The <strong>Vent</strong> Light consists of a LuminAirSafety Extra Low Voltage (SELV) light with whiteceiling bezel and 90 o bend suitable for use withremote extract fan using 100mm duct. On/Offoperation is via the bathroom light switch. Gold andchrome bezels are available as accessories.Stock Ref£Trade453395 - White 65.88Dimensions (mm)A BØ C D E F GLuminAir 150 140 98 103 150 10 180Transformer (Fan) 147 86 65Transformer (Light) 110 35 25Humidity Sensor 87 33Fixing hole diameter 110mmAFan & LightHumidity Sensor<strong>Vent</strong> LightPerformanceExtract performance - FID Max Sound dB(A) AmpsModel m 3 /h l/s Watts @ 3m @ 240VLuminAir L 110 31 40 35 0.2LuminAir T 110 31 42 35 0.2LuminAir H 110 31 44 35 0.234 T: 0844 856 0590


Residential FansLuminAir®Fan & Light<strong>Vent</strong>ilation KitFeatures & Benefits Unique fan and light combination IPX7 rated inlet assembly Suitable for shower enclosures and wetareas - can be used within reach of aperson using a bath or shower Safety extra low voltage (SELV) fan andlamp Easy installation White, Gold and Chrome bezels availableSELV Fan & Light CombinationLuminAir is now additionally available in the formof a ventilation kit. The IPX7 unit is installed directlyover a shower in complete safety.<strong>Vent</strong>-<strong>Axia</strong> LuminAir extracts moisture and humidityat source, preventing damaging condensation fromspreading. At the same time it bathes the showerenclosure in a rich soft light - bringing any darkshower to life. Ideal for all types of bathroom andshower applications, and is particularly suitable forbedsit and en-suite shower installations.Separate lighting transformer also supplied.ModelsLuminAir L, T or H SELV fan and light, choice ofbezel, 90˚ bend, 3m of flex-duct, wall grille andcable ties.LuminAir Shower <strong>Vent</strong>ilation Kit LDOM(Switch Live)Provides simultaneous fan and light operation fromthe bathroom light switch.Stock Ref£Trade453410 - White 139.09LuminAir Shower <strong>Vent</strong>ilation Kit TDOM(Timer)Switches the fan On with the light. When the lightis switched Off, the fan continues to run for anadjustable set period.Stock Ref£Trade453413 - White 190.61LuminAir Shower <strong>Vent</strong>ilation Kit HDOM(Humidistat)Combines a light activated by the bathroom lightswitch and an Ecotronic Humidistat Sensor whichwill switch the fan On whenever the humiditylevel warrants.Stock Ref£Trade453416 - White 220.32Optional BezelsDOMStock Ref£Trade452044 - Chrome 15.54452045 - Gold 32.82Transformer Dimensions (mm)Length Height DepthTransformer (Fan) 147 86 65Transformer (Light) 110 35 25Humidity Sensor 87 87 33Fixing Hole diameter 110mmDimensions (mm)AØ B C DØ E F150 180 139 98 10 32Fixing hole diameter 110mmPerformanceExtract Performance - FID Sound dB(A) AmpsModel m 3 /h l/s Watts @ 3m @ 240VLuminAir <strong>Vent</strong>ilation Kit L/T/H 110 31 40 35 0.2W: www.vent-axia.com 35


Residential FansLuminAir®Turbo Fan & Light<strong>Vent</strong>ilation KitFeatures & BenefitsUnique fan and light combinationIPX7 rated inlet assemblySuitable for shower enclosures and wetareas - can be used within reach of aperson using a bath or showerSafety extra low voltage (SELV) lampEasy installationWhite, Gold and Chrome bezels availableModelsFor applications where a more powerful systemis required, the kit comprises a luminair turbo L orT mains fan and selv light, choice of bezel, 90˚bend, 6 metres of flexible duct, quick fix wall grilleand four cable ties. Meets Building Regulationsapproved Document F performance assumingductwork provided is fully extended and one 90˚bend.Dimensions (mm)AØ BØ C D E F<strong>Vent</strong> Light 150 180 10Turbo Fan 97 178 124 298 96 168Ceiling Fixing hole diameter 110mm<strong>Vent</strong> Light and BendHigh Performance Fan & LightCombinationLuminAir is now additionally available in the formof a ventilation kit. The IPX7 unit is installed directlyover a shower in complete safety.LuminAir Turbo SKL(Switch Live)DOMProvides simultaneous On and Off operation of thefan and light from the bathroom light switch.Stock Ref£Trade453419 - White 155.50<strong>Vent</strong>-<strong>Axia</strong> LuminAir extracts moisture and humidityat source, preventing damaging condensation fromspreading. At the same time it bathes the showerenclosure in a rich soft light - bringing any darkshower to life. Ideal for all types of bathroom andshower applications, and is particularly suitable forbedsit and en-suite shower installations.LuminAir Turbo SKT(Timer)DOMSwitches the fan On with the light. When thelight is switched Off, the fan continues to run foran adjustable fixed period to meet the BuildingRegulations for internal bathrooms.Stock Ref£Trade453422 - White 216.48Turbo FanAØPerformanceOptional BezelsDOMStock Ref£Trade452044 - Chrome 15.54452045 - Gold 32.82Extract Performance - FID Sound dB(A) AmpsModel m 3 /h l/s Watts @ 3m @ 240VLuminAir Tubo SKL/SKT 160 44 35 38 0.3DCEHFTransformer DimensionsBLength Width Lid BaseTransformer T&H 175 90 55 30Transformer (L) 83 76 70 61Humidity Sensor 87 87 33Fixing Hole diameter 110mm36 T: 0844 856 0590


Residential FansSolo® PlusCentrifugal Bathroom/Toilet FanFeatures & Benefits Built-in washable filter feature Meets current Building Regulations ApprovedDocuments F & L requirements for domesticbathrooms and toilets IPX4 rated Flush or surface mountable Adjustable rear or side exit spigot Extremely low sound levels Suitable for wall, ceiling and panel mountingBathroom and Toilet <strong>Vent</strong>ilationThe Solo Plus range from <strong>Vent</strong>-<strong>Axia</strong> has been speciallydesigned for through the wall and ducted applications,suitable for internal bathrooms, toilets and other smallrooms. Finished in white, the Solo Plus can be flush orsurface mounted, with a 100mm circular spigot for rearentry or connecting to a vertical ducting system. Thepowerful centrifugal impeller allows installations using100mm ducting in straight runs up to 50m, whilst stillachieving 15 l/s as required by Document F of thecurrent Building Regulations.All models can be wall, panel or ceiling mountedand can be connected to either circular, rectangularor <strong>Vent</strong>-<strong>Axia</strong>’s flat ducting. Enclosure of the electricalcomponents is manufactured from flame retardantgrade material.Supply voltage 220-240V/1/50Hz.ModelsSolo Plus P(Pullcord)DOMFlush or surface mountable. Control by pullcord singlespeed; 1 of the 3 speeds selectable at installation.Stock Ref£Trade427477 76.12Solo Plus T(Timer)DOMFlush or surface mountable. Constant trickle option. 2Speed. Adjustable timer overrun. Delay on timer option.Stock Ref£Trade427478 100.04Solo Plus TM(Timer/PIR)DOMFlush or surface mountable. Control by integral PIRdetector. Constant trickle option. 2 Speed.Stock Ref£Trade427480 154.12Solo Plus BezelDOMUsed when flush mounting, reduces need to makegood.Stock Ref£Trade437078 9.25Wall Kit Stock Ref:£Trade254102 (White) 17.42254100 (Brown) 17.42Dimensions (mm)BCDEØContinuous running products, such as the Solo Plusinstalled in all wet areas of a dwelling are classed asa wholehouse ventilation system and therefore, onlyneeds to move the amount of air as laid down in table1.1b of Document F.The Solo Plus has a choice of two boost/overridemotor speeds set at installation, medium (17 l/s) or high(25 l/s), with an optional constant trickle speed(10 l/s), also selectable at installation exceptin the P model. Depending on the model,the fan will switch from trickle (if selected)to boost (medium or high) via the pullcord/light switch/humidity sensor/PIR.PerformanceSolo Plus HT(Humidistat-timer)DOMFlush or surface mountable. Humidity controlled fan withoverride pullcord. Constant trickle option. Adjustabletimer overrun. Delay on timer option. Adjustablehumidity sensor.Stock Ref£Trade427479 176.88Extract Performance m 3 /h (l/s) - FID Watts Sound dB(A) @ 3mModel Max Boost Min Boost Trickle Max Boost Min Boost Trickle Max Boost TrickleSolo PlusP/T/HT/TM90 (25) 62 (17) 36 (10) 23 16.5 11.5 40.8 25.8Tested at 240VAC @ 50HzAGJKFLA B C D EØ261 221 107 54.5 98F G H I J64 61 37 98 70Weight 2.7kg.W: www.vent-axia.com 37


Residential FansSolo®Centrifugal Bathroom/Toilet FansFeatures & Benefits100mm high performance centrifugalextract fan for internal bathrooms, toiletsand other small roomsHigh performance 24l/sSingle speed, dual speed and overruntimer modelsSuitable for wall, ceiling, panel andwindow mountingBuilt-in washable filter featurePIR version also availableSuitable for use with flat ductingDouble insulatedIPX4 ratedHigh Performance <strong>Vent</strong>ilationThe Solo range of high performance centrifugalextract fans from <strong>Vent</strong>-<strong>Axia</strong> have been specificallydesigned for effective ducted ventilation of internalbathrooms, toilets and other small rooms. Finished inWhite. The Solo range can be used with 100mmdiameter smooth bore duct in straight runs equalto 50m, yet still meets the 15l/s required by thecurrent Building Regulations Document F forventilation of bathrooms. IP44 Rated.Models are available for surface or recessedmounting directly into standard 100mm diameterducting. Suitable for panel, wall and ceilinginstallations and windows up to 25mm thick. Forhigh rise or coastal applications, install through thewall with a <strong>Vent</strong> Cowl (Stock Ref 561403).ModelsSolo P(Pullcord)DOMSingle speed 24l/s. Control by pullcord or fromlight/remote switch or sensor.Stock Ref£Trade11101010 87.53Solo T(Timer)DOMSingle speed 24l/s. Control by light/remote switch.Overrun timer variable from 5 to 30 minutes.Stock Ref£Trade11101030 115.05Solo TM2(Timer/PIR)DOMControl by integral PIR detector. Fan is switchedON when PIR is triggered. Built-in overrun timer,variable from 5 to 30 minutes, switches fan Off.Stock Ref£Trade11101060 133.58Solo HTPDOM(Humidity and Timer)Humidity controlled single speed fan with pullcordoverride. 17 min overrun timer.Stock Ref£Trade11101080 177.31Wall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Dimensions (mm)AØ B C DØ E F G155 140 36 98 85 55 60Weight 1.35kgWallFront viewSide viewWindowDuct holediameter115mmØ.Window fixinghole Ø113mmPerformanceExtract Performance Max dB(A) AmpsModel m 3 /h l/s Watts @ 3m @ 240VSolo P/T/TM2/HTP 85 24 35 42 0.1538 T: 0844 856 0590


Residential FansSolo® SELV 12Centrifugal Bathroom/Toilet FansFeatures & Benefits Suitable for installation over or withinreach of a shower or bath Built-in washable filter feature Meets current Approved BuildingRegulations Document F IPX7 rated Transformer complies with BS EN 60742 Two speed model available Suitable for wall, ceiling, panel andwindow mountingSafety Extra Low VoltageThe Solo SELV 12 range has been developedspecifically for complete safety in the `splash zone’of a bathroom and shower room for those rooms,usually internal, that need to have the exhaust airducted some distance to an external dischargepoint. A single inlet impeller has been designedfor maximum performance and minimum noiselevels. The grille ensures efficient air managementand incorporates a filter that can be removed forcleaning without dismantling the fan.Suitable for wall, panel and ceiling installations andwindows up to 25mm thick. For high rise or coastalapplications, install through the wall with a <strong>Vent</strong>Cowl (Stock Ref No. 561403). With a powerfulSELV motor and proven high efficiency centrifugalimpeller, Solo SELV 12 can be used with 100mmdiameter smooth bore duct in straight runs equal to50m, yet still meets the 54m 3 /h (15l/s) requiredby the current Building Regulations ApprovedDocument F for ventilation of bathrooms. SoloSELV 12 can also be used with flat ducting forshorter concealed runs.The safety isolating transformer, to BS EN 60742,is mounted in a purpose made enclosure. Theenclosure can be wall mounted or sited in the loft.The enclosure will accept mini trunking.ElectricalGENRear 20mm conduit entry for recessed wiring andside entry grommet for surface wiring.Supply voltage to transformer/controller220-240V/1/50Hz. Output to fan 12V SELV/1/50Hz.To meet IEE Regulations, timer models should beisolated using a 3 pole isolator.3 pole insulatorStock Ref£Trade563518 14.59ModelsSolo SELV 12DOMSafety Extra Low Voltage fan with airflow shutterand washable filter. Mains transformer with 12VSELV output.Stock Ref£Trade11108000 126.06Solo SELV 12T(Timer)DOMSELV fan with airflow shutter and washable filter.Mains transformer with 12V SELV output withpresettable overrun timer (5-30 minutes).Stock Ref£Trade11108030 155.32Solo SELV 12HP(Humidity)DOMSafety Extra Low Voltage fan with airflow shutterand washable filter. Controller. Mains transformerwith 12V SELV output. Remote Ecotronic SELV 12Humidity sensor with pullcord override included.Stock Ref£Trade11108040 213.83Solo SELV 12DP(Two speed)DOMTwo speed Safety Extra Low Voltage (SELV) fanwith airflow shutter and washable filter. Mainstransformer with 12V SELV output.Stock Ref£Trade11108020 177.51Dimensions (mm)AØ B C DØ E F G155 140 36 98 85 55 60Transformer (W x H x D) 175 x 90 x 85Weight 1.35kgWallFront viewSide viewWindowPerformanceExtractPerformance Max dB(A) Amps @Model m 3 /h l/s Watts @ 3m 240VSolo SELV12/T/HP 85 24 39 42 0.26Solo SELV12 DP85452413Duct holediameter115mmØ.Window fixinghole Ø113mmHi 39Lo 204237Hi 0.26Lo 0.12W: www.vent-axia.com 39


RResidential FansVA140/150<strong>Axia</strong>l Kitchen FansFeatures & BenefitsVA140/150 Panel models2 Year GuaranteeThermo electric shutters to prevent backdraftsMeets current Building Regulations ApprovedDocument FIP44 ratedSuitable for wall, ceiling, panel andwindow mountingKitchen ventilationVA140/150 Panel models are designed toalleviate the everyday problems that condensationand household odours may cause. Effectively extractsodours and moisture laden air from kitchens giving ahealthy and fresh environment.Building RegulationsSpecifically sized to meet the current BuildingRegulation requirements for powered extractventilation in domestic kitchens. Control facility fittedas standard. The VA140/150 range is fitted withinternal louvres conforming to the latest internationalsafety standards.Please contact our Customer Service Departmentfor exposed site application.ModelsVA140/150KPDOMSingle speed kitchen extract fan with On/Offpullcord. Trickle ventilation facility.Stock Ref£Trade140120 76.38VA140/150KT(Timer)DOMSingle speed kitchen extract fan with adjustableoverrun timer 3-30 minutes. Trickle ventilation facility.Stock Ref£Trade140220 93.75VA140/150KHP(Humidistat)DOMSingle speed humidity-controlled kitchen extractfan with full speed pullcord override. Humidityadjustment 62-82%RH. Trickle ventilation facility.Stock Ref£Trade140320 151.96VA140/150KHT(Timer/Humidistat)DOMHumidity controlled kitchen extract fan withadjustable overrun timer (3-30 minutes). Humidityadjustment 62-82% RH. Trickle ventilation facility.Stock Ref£Trade140420 166.63VA140/150VSDOMVariable speed kitchen extract with a built inadjustable speed controller, which can reduce thespeed to 40% of its maximum performance.Stock Ref£Trade458915 103.65Dimensions (mm)A B C DØ E FØ G H216 224 80 146 60 152 220 37Weight 1.75kgPanelBPanel fixing hole Ø 152mmWallFØHGWall fixing hole Ø 152mmAAGECDØWall KitDOMStock Ref:£Trade140902 (White) 19.96140903 (Brown) 19.96WindowPerformanceShutter Extract Performance FID SoundModel Actuator m 3 /h l/s Watts dB(A) @ 3mVA140/150KP Pullcord 245 68 18.8 36VA140/150KT/KHP/KHT Instant 245 68 18.8 36VA140/150VS Pullcord 100 low 245 boost 28 low 68 boost 18.8 36Window fixing hole Ø 160mmWindow KitDOMStock Ref£Trade140901A 19.9640 T: 0844 856 0590


Residential FansVA150®Window Mount <strong>Axia</strong>lKitchen FansFeatures & Benefits Complete with window kit 2 Year Guarantee Meets current Building RegulationsApproved Document F IP44 ratedKitchen ventilationVA150 Window models are designed to alleviatethe everyday problems that condensation andhousehold odours may cause. Effectively extractsodours and moisture laden air from kitchens givinga healthy and fresh environment.ShutterThe louvre shutter on the VA150 is concealedbehind the interior grille. Operates automaticallywhen the fan is switched On. Natural trickle ventfacility (unpowered) available on all models.Building RegulationsThe VA150 Range is specifically sized to meetthe current Building Regulation requirements forpowered extract ventilation in domestic kitchens.The VA150 range is fitted with internal and externallouvres conforming to the latest internationalsafety standards.MotorMaintenance free, sealed for life ball bearings inthe purpose made electric motor, economical andquiet running. Double insulated appliance.Supply voltage 220-240V/1/50Hz.ModelsVA150PDOMSpecifically designed for domestic use in kitchensand utility rooms, the VA150P is a single speed150mm (6”) extract ventilation unit for windows.Fan and shutter operated by integral pullcord.(window kit supplied) Colour: white.Stock Ref£Trade152110 107.04VA150ADOMA single speed 150mm (6”) extract fan with instantopening/closing shutter operated by remote switch.Suitable for installation in bathroom or kitchen.(Window kit supplied) Colour: white.Stock Ref£Trade153110 170.78Dimensions (mm)A B C D216 224 130 55Weight 2.5kgABPerformanceShutter Extract Performance - FID Sound dB(A)Model Attenuator m 3 /h l/s Watts @ 3mVA150P/A Pullcord/Instant 220 60 19 37Window fixing hole Ø 184mmW: www.vent-axia.com 41


Residential FansSilhouette® 150<strong>Axia</strong>l Kitchen FansFeatures & BenefitsStylish ultra low profile grilleDownstream airflow guide vanes forimproved pressure developmentModern aestheticsElectric back draught shuttersIPX4 ratedSuitable for wall, ceiling and panelmountingMeets current Building Regulations ApprovedDocument FSlimline Kitchen <strong>Vent</strong>ilationThe <strong>Vent</strong>-<strong>Axia</strong> Silhouette range is designed formodern living. With a profile of only 19mm on thekitchen models, Silhouette blends in with the wallsurface to provide an unobtrusive installation.ModelsSlim profile only 19mm. FID performance of241m 3 /h, double insulated.Silhouette 150XDOMSingle speed 150mm kitchen fan with indicationlight and electric back draught shutter.Stock Ref£Trade454059 73.49Silhouette 150XTSingle speed 150mm kitchen fan with integraladjustable electronic overrun timer (5-30 minutes),indication light and electric back draught shutter.Stock Ref£Trade454060 90.21Dimensions (mm)A B C D G H223 147 111 19 220 37Weight 1.75kgPanelAMounted in the centre of the fan, beneath the ultraslim profile grille, are the electronics, incorporatinga humidistat for detecting a change in internalhumidity or an overrun timer option that is adjustablebetween 5 and 30 minutes.Silhouette 150XHDOMSingle speed 150mm with integral adjustable autohumidity sensor from 60-90% RH, indication lightand electric back draught shutter. Switch live foroverride by remote switch/light switch.Stock Ref£Trade454061 146.23B ØAWall KitDOMStock Ref£Trade140902 (White) 19.96140903 (Brown) 19.96WallCDPerformanceExtract Performance - FIDSound dB(A)Model m 3 /h l/s Watts @ 3mSilhouette 150X/XT/XH 241 67 20 43fixing hole diameter 152mmø (when wall kit used)42 T: 0844 856 0590


Residential FansCentrif® DuoCentrifugal Kitchen &Utility Room FansFeatures & Benefits 100mm circular spigot for speedyinstallation Humidity sensing model for automaticoperation Suitable for both kitchen and utility rooms Removable grille assembly for easycleaning Speed set at installation Meets current Building Regulations ApprovedDocument F Timer model for internal rooms Surface or recessed installation options Includes washable grease filterKitchen and Utility <strong>Vent</strong>ilationThe Centrif Duo range is a series of 100mmcentrifugal extract fans for the domestic environment.The range is designed to provide extractionlevels that comply with Building Regulationrequirements, with special humidity sensingvariants for local authority use.MotorThe motor features greased-for-life ball bearingswhich allow the fan to be installed at any angle.Insulation is Class E. Double insulated appliance.Supply voltage 220-240V/1/50Hz.Fast installationThe Centrif Duo has a 100mm circular spigot. TheFlush mounting kit enables the spigot to be convertedto a side outlet. The spigot also encloses a built-in,spring operated back draught shutter. The CentrifDuo Range can be wall mounted using a telescopicwall fitting kit available as an accessory (requiresa 115mm diameter hole). For ceiling applicationsthe range is ducted either through a soffit outlet orroof cowl assembly. There is convenient access forwiring which can be surface or recessed.Humidistat controlHumidistat is selectable for either kitchen or utilityspeed separate to any other control to reducenuisance noise. Boost operation by pullcord orswitch live.ModelsCentrif Duo P(Pullcord)DOMTwo speed kitchen extract fan with pullcord. Choiceof two speeds for boost, set at installation.Stock Ref£Trade256120 153.34Centrif Duo T(Timer)DOMTwo speed with adjustable timer between 5-30minutes. Choice of two speeds for boost, set atinstallation.Stock Ref£Trade256220 207.52Centrif Duo DP(Two Speed)DOMTwo speed and Off with pullcord or remote switch.Switches between Off, low and one of the 2 boostspeeds.Stock Ref£Trade256320 170.25Centrif Duo HTP(Humidity)DOMIntermittent on 1 of 2 speeds (Utility or Kitchenselectable at installation). Operation by integralhumidity sensor or pullcord. Separate speedsselectable for humidistat and pullcord. Optionalcontinuous trickle speed available at installation.Stock Ref£Trade256420 239.56Flush Mounting KitDOMBezel, clips and 90 o duct elbow, reduces the needto make good.Stock Ref£Trade439256 11.57Dimensions (mm)A B C D E FØ231 261 137 79 58 98Weight 1.75kgWall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Decoration Frame AssembleyDOMStock Ref£Trade442551 16.40Performance Performance @ 0 paHigh speed Med speed Low speed Power (W) Sound dB(A) @ 3mModel m 3 /h l/s m 3 /h l/s m 3 /h l/s Kitchen Utility Trickle Kitchen Utility TrickleCentrif Duo P/T 220 61 130 36 - - 60 41 N/A 51.8 38 N/ACentrif Duo DP/HTP 220 61 130 36 90 25 60 41 9 51.8 38 21.5W: www.vent-axia.com 43


Residential FansCentrif® Duo PlusCentrifugal Kitchen &Utility Room FansFeatures & BenefitsMeets current Building RegulationsApproved Document FOptional filter availableEasy installationFan can be wall or ceiling mountedSuitable for both kitchen and utility roomsConstant trickle boost speed available onDP & HTP modelsUltra Quick <strong>Vent</strong>ilationCentrif Duo Plus is designed to provide extractionlevels that comply with Building RegulationsApproved Document requirements, with specialhumidity sensing variants for local authority use.The Centrif Duo Plus is for kitchens and utility roomsand large bathrooms. Surface mounting directlyinto standard 100mm diameter ducting, through thewall or ceiling installation.Fast installationThe Centrif Duo Plus has a 100mm circular spigot.The Flush mounting kit enables the spigot to beconverted to a side outlet.The spigot also encloses a built-in, spring operatedback draught shutter. The Centrif Duo Plus Rangecan be wall mounted using a telescopic wall fittingkit available as an accessory (requires a 115mmdiameter hole). For ceiling applications the rangeis ducted either through a soffit outlet or roof cowlassembly. There is convenient access for wiringwhich can be surface or recessed.PerformanceImproved Humidistat control for 2011Humidistat is selectable for either kitchen or utilityspeed separate to any other control; to reducenuisance noise. Boost operation by pullcord orswitch live.ModelsCentrif Duo Plus P(Pullcord)DOMTwo speed kitchen extract fan with pullcord. Choiceof two speeds for boost, set at installation.Stock Ref£Trade431613 153.34Centrif Duo Plus T(Timer)DOMTwo speed with adjustable timer between 2-30minutes. Choice of two speeds for boost, set atinstallation.Stock Ref£Trade431614 207.53Centrif Duo Plus DP(Two speed)DOMTwo speed and Off with pullcord or remote switch.Switches between Off, low and one of the 2 boostspeeds.Stock Ref£Trade431615 170.27Centrif Duo Plus HTP(Humidity)DOMIntermittent on 1 of 2 speeds (Utility or Kitchenselectable at installation). Operation by integralhumidity sensor or pullcord. Separate speedsselectable for humidistat and pullcord. Optionalcontinuous trickle speed available at installation.Stock Ref£Trade431616 239.56Performance @ 0 paHigh speed Med speed Low speed Power (w) Sound (dBA@3mModel m 3 /h l/s m 3 /h l/s m 3 /h l/s Kitchen Utility Trickle Kitchen Utility TrickleCentrif Duo P/T 220 61 130 36 - - 60 41 N/A 51.8 38 N/ACentrif Duo DP/HTP 220 61 130 36 90 25 60 41 9 51.8 38 21.5Flush Mounting KitDOMBezel, clips and 90 o duct elbow reduces the needto make good.Stock Ref£Trade439256 11.57Centrif Duo Plus FilterDOMStock Ref£Trade439927 5.79Dimensions (mm)A B C D E FØ231 261 140 79 58 98Weight 1.75kgBEDAWall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Decoration Frame AssembleyGENStock Ref£Trade442551 16.40CF44 T: 0844 856 0590


Residential FansDuet® Twin FansBathroom/ToiletRun & Standby FansFeatures & Benefits Designed to meet Local Authority run andstandby specifications Quiet operation Meets current Building Regulations ApprovedDocument F Run and standby facility Self diagnostic check of controls Overrun timer as standard Remote PIR’s or humidistat can be installedBathroom ventilationDuet is a range of run and standby fans designed toprovide extraction levels that comply with BuildingRegulations Approved Document F for bathroomsand toilets and incorporates a run on timer. Allmodels offer automatic change over on fan failure.Ultra quiet and particularly suitable for areas whereunobtrusive sound levels are essential. Duet meetsthe requirement of Health Technical Memorandum2025, foul extract ventilation systems 2.8. Ideal fornew build and refurbishment installations.Duet features include LED indicators showing thestatus of the unit, self diagnostic check of controlsbefore the fan will start, run and standby facility,5-25 minute run on timer and 24 hour auto fanchange over. Suitable for ambient temperatures ofup to +40˚C, built-in dust filters.Double insulated appliance.Supply voltage 220-240V/1/50Hz.Duet is suitable for use with either 100mm diameterducting or flat ducting, for installations that needconcealed ducting, with a minimal ceiling void ofonly 90mm required.ModelsDuet SurfaceDOMRequires 100mm circular hole in wall. Fan 1/Fan 2running indicators, fault indicator.Stock Ref£Trade180510 284.76Duet RecessedDOMFlush-mounted model with 100mm dischargespigot. Two flush-mounted washable filter panels,Fan 1/Fan 2 running indicators, fault indicator.Stock Ref£Trade180610 338.25Duet DuctDOMSheet metal construction. Up to 2 inlets can beconnected. 100mm discharge spigots.Stock Ref£Trade180710 319.45Remote IndicatorDOMThe remote indicator unit provides fan statusinformation at a convenient position.Stock Ref£Trade180010 54.36Dual sized spigotDOMStock Ref£TradeGTFSP 12.68Wall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Dimensions (mm)A B C D EØ F GSurface 347 170 224 69 99 35Recessed 385 233 366 255 98 230 35Duct 366 233 230 36 98Duet SurfaceCDEØDuet RecessedDFEØDuet DuctAF BCGBAPerformanceExtract Performance - FID Sound dB(A) AmpsACEØDBModel m 3 /h l/s Watts @ 3m @ 240VSurface/ Recessed/ Duct 122 33 35 One fan running 34 0.2599Ø952549ØOptionalDual sized spigots togive either 50mm or100mm standard pipePart number GTFSPW: www.vent-axia.com 45


Residential FansGemini Twin FansKitchen/UtilityRun & Standby FansFeatures & BenefitsSuitable for kitchen and utility roomapplicationsComes complete with a plug in powerpackDuty sharing features supplied as standardMeets current Building Regulations ApprovedDocument FSurface, flush and duct mounting versionsare availableOverrun timer as standardRemote PIR’s or humidity sensors can beinstalledInstallationThe <strong>Vent</strong>-<strong>Axia</strong> Gemini range is designed forinstallation in kitchens and utility rooms. Surface,flush or duct mounting models are available. Theunits meet current Building Regulations ApprovedDocument F.ModelsGemini SurfaceDOMA surface mounted twin fan model with 100mmspigot.Model Stock Ref £TradeGTFS 457479 343.62Dimensions (mm)A B C D EØ F GSurface 347 170 224 69 99 35Recessed 385 233 366 255 98 230 35Duct 366 233 230 36 98Gemini SurfaceUltra quiet ventilationThe <strong>Vent</strong>-<strong>Axia</strong> Gemini range of run and standbyfans offers high performance double inlet forwardcurve fan motor impellers, typically suitable forhigh system resistance installation. In the event offailure the standby fan is operated, and visual fanfailure indication (via integrated or optional remoteindication light) is illuminated. The surface mountingmodel has a styled cover. For flush or duct mountingthe power pack and back plate assembly is locatedwithin a galvanised steel casing and fitted with eithera PVC cover for flush mounting or a galvanised steelcover for connection to ducts.The Gemini range has an integrated overruntimer function fitted as standard, enabling versatileoperation to comply with the Building RegulationsApproved Document F for internal rooms andLocal Authority specification. The overrun timercan be manually adjusted between 1 and 20minutes. (Units are factory set with the timer set toapproximately 20 minutes).All models incorporate a basic power pack whichincludes the motor housing, power on, fan run andfan fail indication light, which allows you to install theback plate at the first fix stage and plug in the powerpack when the unit is ready for use. The power packis pre-wired and incorporates a plug in arrangementfor fitting to the back plate.Gemini RecessedDOMA flush mounted twin fan model for recessedapplications.Model Stock Ref £TradeGTFF 457480 387.51Gemini DuctDOMA twin fan ducted model for in-line applications.Model Stock Ref £TradeGTFD 457481 372.38Remote IndicatorDOMThe remote indicator unit provides fan statusinformation at a convenient position.Stock Ref£Trade180010 54.36Dual sized spigotDOMStock Ref£TradeGTFSP 12.68Wall KitDOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42PerformanceCDDCAAGemini RecessedGemini DuctExtract Performance - FID Sound dB(A) Speed Max MaxModel m 3 /h @ 3m RPM Watts AmpsSurface 216 43 1370 57 0.19Recessed 205 44 1370 57 0.19Duct 195 46 1370 57 0.19AF99ØCEØEØEØGDF952549ØBBBOptionalDual sized spigots togive either 50mm or100mm standard pipePart number GTFSP46 T: 0844 856 0590


Residential FansCooker HoodsFeatures & BenefitsA choice of four styles for domesticapplicationsWall, ceiling or cabinet fixedCompatible with flat ducting or <strong>Vent</strong>-<strong>Axia</strong>aluminium flexible ductingAll models are provided with a charcoalfilter and washable grease filter asstandardAll models are fitted with mains lead,built-in lighting and choice of 3 speedsKitchen <strong>Vent</strong>ilation<strong>Vent</strong>-<strong>Axia</strong> offers a range of cooker hoods for theremoval of cooking odours and steam at sourcein the domestic kitchen. Each model is designed toprovide the extraction levels necessary to complywith Building Regulation requirements for kitchenswith ducted outlets plus models that provide higheroutputs for busier kitchens.A choice of styles is available to include wall,or cabinet fixed models to provide integratedventilation in any modular fitted kitchen from aterraced galley kitchen to the most extensivelayouts. Models are available that can re-circulateor extract with the use of ducting.The Building Regulations for the mechanicalventilation of kitchens with open-able windows indwellings require that extractor hoods should becapable of extracting at a rate of 30 l/s (108m 3 /h).When used with ducting, the resistance of the entiresystem should be considered so that the requiredperformance is achieved. Extractor hoods shouldnot be sited where ambient temperatures are likelyto exceed +50˚C.ModelsGenovaDOMAn cooker hood with ‘flip front’ glass visor designedto be wall-mounted or mounted beneath a topcabinet. Offering three speeds with extract rates of100/160/220m 3 /h.Stock Ref£Trade120801 96.16NapoliDOMAn integrated cooker hood designed to accept akitchen cupboard door-panel in matching height andfinish to existing units. Offering three speeds withextract rates of 120/170/220m 3 /h.Stock Ref£Trade120811 (White) 158.68436084 (Silver) 229.59Rimini/Milano/RomaDOMThe Rimini (500mm width), Milano (600mm width)and Roma (900mm width) are stainless steelchimney cooker hoods with an extending chimneyto fit varying ceiling heights. Offering three speedswith extract rates of 340/420/460m 3 /h.Stock Ref£Trade427166 - Rimini 272.47120841 - Milano 478.26120851 - Roma 517.55Dimensions (mm)Model W D HGenova 600 470 150Napoli 600 275 450Rimini 500 500 1115Milano 600 500 1115Roma 900 500 1115Extractor hoods are not suitable for use abovean eye level grill.Must be mounted between 760mm and 900mmabove the hob.48 T: 0844 856 0590


Residential FansBasic, Simple, SolutionBathroom/ToiletBAS100BBASUnshuttered axial fan for remote or light switchoperation.Stock Ref£Trade436519 30.78BAS100PBASUnshuttered axial fan with integral pullcord.Stock Ref£Trade436520 37.99BAS100TBASUnshuttered axial fan with adjustable overrun timer.Stock Ref£Trade436521 46.50KitchenBAS150BBASUnshuttered axial fan designed for remote or lightswitch operation.Stock Ref£Trade436525 58.95BAS150PBASUnshuttered axial fan with integral pullcord.Stock Ref£Trade436526 62.88BAS150TBASUnshuttered axial fan with adjustable overruntimer.Stock Ref£Trade436527 72.05Shower Fan & KitMinivent SKBASSingle speed 100mm in-line axial fan.Stock Ref£Trade248710 37.33Minivent SKTBASSingle speed 100mm in-line axial fan with integraladjustable overrun timer - 5-30 minutes.Stock Ref£Trade248810 45.78The kit consists of a IP44 In-Line fan, a white ceilinggrille and spigot, 3 meters of flexible duct and anexternal louvre for soffit or wall mounting.BAS100SLBBASSingle speed axial fan with integral back draughtshutter for remote or light switch operation.Stock Ref£Trade436530 32.11BAS100SLTBASSingle speed axial fan with electronic overrun timer(5-30 minutes) and integral back draught shutter.Stock Ref£Trade436532 47.81BAS150SLBBAS<strong>Axia</strong>l fan with integral back draught shutter forremote or light switch operation.Stock Ref£Trade436533 68.12BAS150SLTBASSingle speed axial fan with electronic overrun timer(5-30 minutes) and integral back draught shutter.Stock Ref£Trade436535 79.92Shower Fan & Light KitBASBasicStock Ref£Trade432504 91.70The kit consists of a 100mm axial in-line fan 3meters of flexible ducting, an exterior grille, lighttransformer and 12V 35W dichroic halogen lightassembly. IP44 rated.TimerStock Ref£Trade432505 104.80W: www.vent-axia.com 49


Residential FansEclipseBathroom& Kitchen <strong>Axia</strong>l FanFeatures & BenefitsWall or Ceiling mountableIntegral back draft shutter mechanismMeets current Building RegulationsApproved Document F100mm and 150mm size optionsFixing kits availableFan IP44 rated -100mmFan IPX4 rated -150mmBathroom ventilationThe Eclipse range of circular axial fans is designedto be installed in kitchens and bathrooms. Itssimple design provides an unobtrusive fitting thatis sympathetic with most interiors.ModelsECLIPSE 100XBASSingle speed 100mm bathroom/toilet fan withback draught shutter.Stock Ref£Trade427310 43.51ECLIPSE 150XPBASSingle speed150mm Kitchen fan with pullcordand aesthetical shutter.Stock Ref£Trade427313 58.46ECLIPSE Chrome BezelSPStock Ref£Trade436480 5.54Wall KitDOMWall fixing hole for 150mm Ø165mm.Stock Ref£Trade140902 (White) 19.96140903 (Brown) 19.96Wall fixing hole for 100mm Ø117mm. DOMStock Ref£Trade254102 (White) 17.42254100 (Brown) 17.42Dimensions (mm)Model A B C DEclipse 100 157 99 107 19Eclipse 150 201 144 123 19ABECLIPSE 100XPBASSingle speed 100mm bathroom/toilet fan withpullcord and back draught shutter.Stock Ref£Trade427281 46.21Performance50CDECLIPSE 100XTBASSingle speed 100mm bathroom toilet fan withintegral adjustable overrun timer (5-30 minutes)and back draught shutter.Stock Ref£Trade427282 53.01ECLIPSE 150XBASSingle speed 150mm kitchen fan with backdraught shutter.Stock Ref£Trade427283 55.74Pressure (Pa)403020101200 50 100 150 200 250 300Volume Flow m³/h1 Eclipse 100 2 Eclipse 15050 T: 0844 856 0590


W: www.vent-axia.com 51


dMEV, MEV &PIV SystemsWhat is MEV & dMEV?The current Building Regulations ApprovedDocument F gives examples of four mainmethods of ventilation. System 3, Continuousmechanical extract ventilation can be achievedusing a single centralised extract unit such asthe Sentinel Multivent ducted from ‘wet’ rooms(kitchen, bathroom, en-suite and WC) or bydecentralised individual fans (dMEV) in the ‘wet’rooms. The fans run continuously at near silentlevels providing a simple and effective formof ventilation.The Centra meets the latest requirements of thecurrent Building Regulations Approved DocumentF for wholehouse system ventilation.Positive Pressure <strong>Vent</strong>ilationFor controlling condensation particularly in therefurbishment sector, the <strong>Vent</strong>-<strong>Axia</strong> PoziDry offersa quick and simple solution. A loft mountedpositive input fan draws fresh air from atmosphere,filters it and pushes into the dwelling via a ceilingmounted diffuser. All stale air in the property isforced out through the natural forms of ventilation,such as window mounted trickle vents.Range52 T: 0844 856 0590


The most comprehensive range ofMEV & PIV solutions on the market today.W: www.vent-axia.com 53


Lo-CarbonCentra®/SELVdMEV UnitFeatures & Benefits Building Regulations Approved Document Fcompliant, System 3 Continuous mechanicalextract SAP Appendix Q eligible - Low SFP onSAP Q Quietest dMEV available Discreet, tasteful styling Single fan for use in all applications IPX4 rated - IPX7 rated (SELV) Pressure detection device Normal and Boost speeds Lo-Carbon motor offering 90% energysavings and long life 5 Year Motor Guarantee Suitable for wall, ceiling, paneland window mounting SELV Models - Supplied with a remotetransformer SELV Models Suitable for ‘Zone 1’installationWhat is de-centralised MEV (dMEV)The Building Regulations Approved Document Fgives examples of four main methods of ventilation.System 3, Continuous mechanical extract ventilationcan be achieved using a single centralised extractunit such as the Sentinel Multivent ducted to ‘wet’rooms (kitchen, bathroom, en-suite and WC) or bydecentralised individual fans in the ‘wet’ rooms. Thefans run continuously at near silent levels providing asimple and effective form of ventilation.SELV (Safety Extra Low Voltage) is designed forareas where a fan can be installed within Zone 1 ina room where there is a fixed bath or shower. IngressProtected (IP) to IPX7 Lo-Carbon Centra SELV canbe fitted safely within the spray area. The separatetransformer can be mounted away from the sprayzone and out of reach from the bath or shower.The Lo-Carbon Centra meets the latest requirementsof the Building Regulations Approved Document F forwholehouse system ventilation.Selection of the two normal flow rates (6l/s or 9l/s)is via a simple ‘jumper’ on the control board. Differentmethods are available for operating boost speedfrom a simple switched live to integral humidistat orCO 2sensor. See individual models for further details.The attractive and discreet styling of the <strong>Vent</strong>-<strong>Axia</strong>Lo-Carbon Centra will complement the décorof any new home while virtually silent operationensures optimum ventilation is achieved withoutintrusive noise.Lo-Carbon CentraThe SAP Appendix Q eligible Lo-Carbon Centra hasa specific fan power of only 0.18 W/l/s in throughthe-wallkitchen applications.ModelsLo-Carbon CentraCASAuto speed selection at installation. The integral airpressure sensor checks the airflow when first installedand also helps the fan to compensate for externalwind pressure.Stock Ref£ Trade441782 99.56Lo-Carbon Centra/SELV TDOM(Timer)Ideal for bathroom and toilet applications, this unitruns continuously on trickle setting and may beboosted by the switched live input which activatesthe adjustable timer (5-30 minutes).Model Stock Ref £ TradeT 442954 112.82SELV T 443175 138.42Lo-Carbon Centra/SELV TPDOM(Pullcord/Timer)For bathroom/toilet applications, the continuousrunning TP model is boosted by the pullcord whichactivates the adjustable timer (5-30 minutes).Model Stock Ref £ TradeTP 447127 126.62SELV TP 447128 151.66Lo-Carbon Centra/SELV HTDOM(Humidistat/Timer)For bathroom/toilet applications, the continuousrunning HT model is automatically boosted by thebuilt-in humidistat or by a switched live input whichactivates the adjustable timer (5-30 minutes).Model Stock Ref £ TradeHT 442955 147.49SELV HT 443176 173.30Lo-Carbon Centra/SELV HTPDOM(Humidistat/Pullcord)For bathroom/toilet applications, the continuousrunning HTP model is automatically boosted by thebuilt-in humidistat or by the pullcord which activatesthe adjustable timer (5-30 minutes).Model Stock Ref £ TradeHTP 443045 147.49SELV HTP 443177 173.30Lo-Carbon Centra CO 2and Humidity CASContinuous running, automatically boosted withintegral CO 2and humidistat sensor. This as ambientresponse feature - detects rapid change in %RHand boosts immediately, or will boost slowly andproportionally with %RH or CO 2.Stock Ref£ Trade444672 219.40150mm Conversion KitGENStock Ref£ Trade443334 23.16Wall KitDOMStock Ref£ Trade254102 (White) 17.42254100 (Brown) 17.42Window KitDOMStock Ref£ Trade442947 18.84Ceiling KitDOMStock Ref£ Trade443800 12.8054 T: 0844 856 0590


Lo-Carbon Residential FansWINNER2011Winners of the Energy Efficiency Initiative 2011 Awardwith our Lo-Carbon Continuous <strong>Vent</strong>ilation <strong>Product</strong> Range.ELIGIBLE FORSAP APPENDIX QDimensions (mm)160 35 11516099ØTransformer 87 x 87 x 33mm (W x H x D)Performance Guide Extract Performance (l/s) Power consumption (Watts) Sound dB(A)@ 3mTrickle Trickle Trickle Trickle Trickle TrickleModel low high Boost low high Boost low high BoostLo-Carbon Centra/SELV T/TP/HT/HTP/ CO 26 9 15 1.4 1.6 2.4 10.8 15.5 25.2SAP Appendix Q PerformanceSystems With Rigid Ductwork Installation OnlyUnit Configuration Location Fan Speed Setting Flow Rate (L/s)Flow Rate - WindCondition (l/s)Specific Fan Power(W/l/s)% Reduction Of TotalFlow RateIn Room (Ducted) Kitchen High 13.2 12.4 0.32 6In Room (Ducted) Wet Room 9 L/s 8.4 8.0 0.28 5Through Wall Kitchen High 13.5 13.0 0.18 4Through Wall Wet Room 9 L/s 8.6 8.0 0.20 8Systems With Flexible Or Mixed Ductwork Installation OnlyUnit Configuration Location Fan Speed Setting Flow Rate (l/s)Flow Rate - WindCondition (l/s)Specific Fan Power(W/l/s)% Reduction Of TotalFlow RateIn Room (Ducted) Kitchen High 13.2 12.5 0.32 5In Room (Ducted) Wet Room 9 L/s 8.6 7.9 0.28 8Through Wall Kitchen High 13.5 13.0 0.18 4Through Wall Wet Room 9 L/s 8.6 8.0 0.20 8W: www.vent-axia.com 55


dMEV, MEV & PIV SystemsLo-CarbonMultiventMEV UnitFeatures & Benefits Fitted with four extract 125 or100mm diameter spigots allowingquick connection to ducts Option of wall, ceiling and loft mounting Quiet operation suitable forcontinuous operation Can extract from a number of rooms,depending on the dwelling Wireless Controller availableThe Lo-Carbon Multivent continuous mechanicalextract ventilation range is designed for thesimultaneous ventilation of separate areas in thehome or as a multi-point extractor system for a widerange of commercial applications.In the home the system is usually located in the loft orairing cupboard with ducts taken to the bathroom,kitchen and utility room to remove water vapour atsource and from toilets to remove odours.Lo-Carbon Multivent is ideal for a range ofcommercial multipoint extract applications suchas toilets, fitting rooms, and kiosk’s. The units canbe installed at any angle and where the ambientair has a high humidity content condensate drainsare provided.The Lo-Carbon Multivent H version incorporates abuilt-in humidity sensor to switch between 2 of the3 speeds. A Wire-less Controller is available foruse with the Lo-Carbon Multivent H with 3 speedoptions offering total control of the systems.Lo-Carbon MVDCThe Lo-Carbon MVDC Multivent minimises runningcosts by incorporating the latest DC technology.DC efficiency means less wear and tear on themotor which guarantees longer life.Extended motor guarantee to 5 years offered.Acoustic Lining KitCASFor reducing noise in sensitive installationsStock Ref£ Trade438195 16.21ModelsCASModel Stock Ref £ TradeMVDC 181520 241.00MVDCH 183020 261.07Multivent Wire-less ControllerCAS(for use with MVDCH only)Stock Ref£ Trade426035 26.59Sound LevelSound dB(A) @ 3mFID Perf. Casing Duct Inlet Duct InletModel m 3 /h (l/s) Breakout 100mmØ 125mmØMVDClow 232 (64) 33.3 36.5 36.5medium 365 (100) 33.7 47.9 47high 434 (120) 38.8 51.7 51.5MVDCHlow 232 (64) 33.3 36.3 36.5medium 365 (100) 33.7 47.9 47high 434 (120) 38.8 51.7 51.5Performance CurveSTATIC PRESSURE (Pa)500400High300Medium200100Low00 100 200 300 400 500Output m 3 /hDimensions (mm)Weight: 5.50kg340249125ØTechnical DataLow Medium HighCurrent Power Current Power Current PowerModel Amps Watts Amps Watts Amps WattsMVDC 0.1 9 0.23 20 0.39 45MVDCH 0.1 9 0.23 20 0.39 44100Ø310100Øreduction piecesdiameter: 100/125mm56 T: 0844 856 0590


dMEV, MEV & PIV SystemsMultiventMEV UnitFeatures & Benefits Fitted with four extract 125 or100mm diameter spigots allowingquick connection to ducts. Option of wall, ceiling and loft mounting. Quiet running suitable forcontinuous operation. Can extract from a number of rooms,depending on the dwelling. Wire-less Controller available.The Multivent continuous mechanical extractventilation range is designed for the simultaneousventilation of separate areas in the home or as amulti-point extractor system for a wide range ofcommercial applications.In the home the system is usually located in the loft orairing cupboard with ducts taken to the bathroom,kitchen and utility room to remove water vapour atsource and from toilets to remove odours.Multivent is ideal for a range of commercialmultipoint extract applications such as toilets, fittingrooms, and kiosk’s. The units can be installed atany angle and where the ambient air has a highhumidity content condensate drains are provided.The Multivent H version incorporates a built-inhumidity sensor to switch between 2 of the 3speeds. A Wire-less Controller is available for usewith the Multivent H with 3 speed options offeringtotal control of the systems.Acoustic Lining KitCASFor reducing noise in sensitive installationsStock Ref£ Trade438195 16.21ModelsCASModel Stock Ref £ TradeMV250 181510 202.80MV250H 183010 232.14Multivent Wire-less ControllerCAS(for use with MV250H only)Stock Ref£ Trade426035 26.59Sound LevelSound dB(A) @ 3mFID Perf. Casing Duct Inlet Duct InletModel m 3 /h (l/s) Breakout 100mmØ 125mmØMV 250low 161 (45) 22.4 27.9 27.8medium 305 (85) 31.0 42.9 43.2high 443 (123) 35.4 48.6 48.0MV 250Hlow 175 (48) 22.4 27.9 27.6medium 344 (95) 31.0 42.9 43.2high 443 (123) 35.4 48.6 48.0Performance CurveSTATIC PRESSURE (Pa)400300High200Medium100Low00 100 200Output m 3 300 400 500/hDimensions (mm)Weight: 5.50kg249340125ØTechnical DataLow Medium HighCurrent Power Current Power Current PowerModel Amps Watts Amps Watts Amps WattsMV250 0.2 25 0.30 54 0.34 81MV250H 0.2 25 0.30 54 0.34 81100Ø310100Øreduction piecesdiameter: 100/125mmW: www.vent-axia.com 57


Lo-CarbonSentinel® MultiventMEV UnitFeatures & Benefits Reduces your carbon footprint SAP Appendix Q Eligible Specific fan power 0.16 W/l/s (K+1) Suitable for use with external sensors andcontrollers Wireless control option Ultra quiet - acoustically lined for low noiselevels Complies with Building Regulations ADF(System 3) Manufactured in the UK fromre-cyclable materialsSentinel Multivent continuous mechanical extractventilation, C-MEV is designed for the simultaneousventilation of separate areas in the home or as amulti-point extraction system for a wide range ofcommercial applications. The units can be installedat any angle. Where the ambient air has a highhumidity content condensate drains are provided.In support of Sentinel Multivent,<strong>Vent</strong>-<strong>Axia</strong> offers: Practical advice on product selection andinstallation Guidance on solutions to meet legislationrequirements Project management and site deliveries After sales support and maintenanceinformationThe need to improve efficiencySentinel Multivent has been designed to meet theexacting demands of developers, installers andusers offering advanced control options and easierinstallation and commissioning. Demand Control - enables precise ventilationrate is set in 1% increments based onproperty size Integral LCD display allows installer to selectappropriate low, normal and boost speeds tomeet demand Manual and automatic control options Integral adjustable overrun timer and delayon timer Plug-n-Play automatic sensor detection Switched live and SELV connections Dry Out setting – Option set at installation,Sentinel Multivent will run on boost for 1week to assist in removing moisture Optional Wireless Control – up to 4controllers on any one system Energy efficient EC/DC motors - 1/3 lessenergy lost to heat than a conventional ACmotor Low Specific Fan Power (SFP) making it oneof the most efficient products on the marketLegislation Meets Building Regulations ApprovedDocument F (System 3) SAP Appendix Q listed up to kitchen + 6 wetrooms Meets carbon footprint reduction targets Lowest SFP figures of any demand controlMEV systemThe need for better healthRemoval of pollutants, such as moisture, carbondioxide and external fumes are all important factorsin maintaining indoor air quality, helping to create abetter living environment. The integral humidity sensor (SentinelMultivent H) increases fan speed inproportion to relative humidity levels, savingenergy and reducing noise The sensor also reacts to small but rapidincreases in humidity, even if the normaltrigger threshold is not reached. This uniquefeature ensures adequate ventilation, even forthe smallest wet-room Night time relative humidity incrementsetback feature suppresses nuisance trippingas humidity gradually increase with fallingtemperature Acoustically lined - low noise levels only 18.1dB(A) @3mDimensions (mm)15Model2534036072.5CASModel Stock Ref. £ TradeSentinel Multivent 437601 362.00Sentinel Multivent H 445655 388.08SAP Appendix Q214310Reduction PiecesDiameter: 100/125mmØ125In order to make the right choice, developers andcontractors should refer to Building RegulationsADL1a, SAP 2009 and Appendix Q.SAP Appendix Q was launched in June 2006 toreward innovative ventilation manufacturers bytesting and listing energy efficient products thatassist in helping developers meet their TargetEmission Rates (TER).SAP is the underpinning methodology behind theEnergy Performance Certificates and is used todemonstrate compliance with Building Regulationsfor Dwellings - Approved Document L (Englandand Wales), Section 6 (Scotland) and ApprovedDocument F (Northern Ireland). Appendix Qspecifically relates to wholehouse ventilationsystems and lists a number of <strong>Vent</strong>-<strong>Axia</strong> Mechanical<strong>Vent</strong>ilation solutions which offer an improvedSAP rating over and above the default for theseproduct types.8526015058 T: 0844 856 0590


dMEV, MEV & PIV SystemsELIGIBLE FORSAP APPENDIX QSAP Appendix Q Test ResultsExhaust Terminal Fan speed Total Specific FanConfiguration setting flow rate Power (W/l/s)Kitchen + 1 additionalwet room32% 21 0.16Kitchen + 2 additionalwet rooms39% 29 0.16Kitchen + 3 additionalwet rooms49% 37 0.17Kitchen + 4 additionalwet rooms59% 45 0.21Kitchen + 5 additionalwet rooms68% 53 0.24Kitchen + 6 additionalwet rooms77% 61 0.29To assist developers and contractors <strong>Vent</strong>-<strong>Axia</strong> canprovide detailed scheme designs together withinstallation guidance and training.Your Carbon FootprintThe Carbon Footprint is a measure of the amount ofcarbon dioxide (CO 2) emitted through the burningof fossil fuels. From a residential and commercialbuilding perspective, it is the amount of carbongenerated when you produce a kilowatt of electricity.Reducing a building’s carbon footprint will ultimatelyreduce electricity bills and save money for everyindividual household or business. It will also helpmeet the UK target for the reduction of emissions,as well as allowing you to help the environment.Performance CurveStatic Pressure Pa40035030025020015010050Performance Guide10%100%00 50 100 150 200 250 300 350 400 450 m 3 /h0 10 20 30 40 50 60 70 80 90 100 110 120VolumeInfinitely variable performanceMinCasing Breakout Inlet Duct Speed FID PowerStock Ref dB(A) @ 3m dB(A) (pwm) l/s Watts437601445655Fully AdjustableSpeed SettingsMin 18.1 17.0 10% 17 4Max 36.8 35 100% 125 45l/sSound DataSpeed Induct sound power levels dB dB(A)(PWM) 63 125 250 500 1K 2K 4K 8K @ 3m10% Breakout 43.6 37 36.9 30.6 26.2 22.8 23.6 30.4 18.110% Extract 43.8 39.9 36.1 30.4 24.6 21.8 22. 30.3 17.828% Breakout 44 44.4 43.3 39 31.1 26.1 24.3 30.1 2228% Extract 42.2 40.1 42.2 40.5 32 23.3 23.4 30.5 2246% Breakout 45 42.8 46.7 44.1 38.8 35.6 26.7 30.6 25.846% Extract 40.8 42.5 46.4 44.4 41 31.1 25.3 30.3 2682% Breakout 46.3 48.3 50 52.1 48.4 47.7 37.8 32.4 33.782% Extract 46.7 49.6 48.9 54.3 51.8 42.7 38.1 34.2 36.1W: www.vent-axia.com 59


Lo-Carbon Sentinel® MultiventdMEV, MEV & PIV SystemsControllers and SensorsSentinel Multivent can be used with a wide range of <strong>Vent</strong>-<strong>Axia</strong> controllers and sensors. Ranging from integral humidistats, through wireless controllers to wiredremote sensors.Integral HumidistatCAS Simple Plug-n-Play installation Eliminates the need for additional controllersor sensors Reacts to any rapid increases in relativehumidity or relative humidity above 60% Future proof – can be fitted after installation Self programmingStock Ref.£ Trade437598 36.81Ambient Response Humidity Sensor Pullcord override and indication light Changeover relay switch Operating range: 30% - 90%RH Ambient operating temp. 5°C to 40°C 220-240V ACGEN Will fit single gang box for surface mountingStock Ref.£ Trade563550 162.30Visonex PIR Sensor Fits any UK single gang mounting box Adjustable timer overrun (5-25 mins) Range of detection up to 10 metres Designed to meet IP43GEN Ambient operating temp. range 0°C to 50°CStock Ref.£ Trade459623 91.72Wireless Transmitter ControllerReceiver Kit Manual boost Adjustable overrun timer Easy wire-less installation Reduces installation time Future proof - add more controllers at anyCAStimeStock Ref.£ Trade439352 73.63Ecotronic Humidity Sensor Set Point adjustable Maximum switching load 1 amp inductive Pullcord override indicator Ambient operating temp. 0°C to 40°CGEN Supply voltage 220-240VStock Ref.£ Trade563532 88.44CO 2+ Temp Room SensorIND 240V DC 0 - 2000ppm CO 2working range. 0 - 50°C working range Auto-calibrating NDIR CO 2absorption sensor Thin film platinum temperature sensor for highaccuracyStock Ref.£ Trade433257 475.38Wireless Transmitter ControllerCAS Additional controller for 439352 A maximum of 4 controllers can be used persystem Can be connected to other accessories (egHumidistat) to send a boost signal wirelesslyStock Ref.£ Trade437827 42.96Air Quality Sensor Ambient operating temp. 0°C to 50° Min - Max mode or direct damper control Surface mounted 1 - 25 min O/R timerGEN Supply voltage 220-240VStock Ref.£ Trade563506 177.37<strong>Vent</strong>wiseCAS Automatically boosts fan when temperature ofthe supply pipe to a shower or bath increases Automatically boosts fan when electric hob isswitched on Can be used in conjunction with manualoverride input Adjustable overrun timer Two sensor options available.Stock Ref.£ Trade435960 316.0660 T: 0844 856 0590


Lo-CarbonMultiventELIGIBLE FORSAP APPENDIX QdMEV, MEV & PIV SystemsMVDC-MS/MSHMEV UnitFeatures & Benefits Reduces your carbon footprint SAP Appendix Q Listed Fitted with four extract 125 or100mm diameter spigots allowingquick connection to ducts Complies with Building ADF (System 3) Option of wall, ceiling and loft mounting Improved controllability Switched Live Boost connection Fully variable normal and boost speeds Ultra quiet - acoustically lined for low noiselevels Integral humidistat (H version)ModelsCASModel Stock Ref £ TradeMVDC-MS 437634 288.25MVDC-MSH 443298 311.40SAP Appendix Q Test ResultsExhaust Terminal Total Specific FanConfiguration flow rate Power (W/l/s)Kitchen + 1 additional wet room 21 0.16Kitchen + 2 additional wet rooms 29 0.15Kitchen + 3 additional wet rooms 37 0.17Kitchen + 4 additional wet rooms 45 0.20Kitchen + 5 additional wet rooms 53 0.24Kitchen + 6 additional wet rooms 61 0.28Dimensions (mm)Weight: 5.50kg249100Ø310100Ø340125Øreduction piecesdiameter: 100/125mmWith growing concerns about accurate ventilationof properties, the Lo-Carbon Multivent MVDC rangeoffers the option of ‘Close Control’ both in theresidential and the commercial sectors. With a DCmotor the multi speed Lo-Carbon Multivent is one ofthe most efficient central extract units in the UK.The units have 2 fully variable speeds for trickle andboost, with a switched live (LS) activation for theboost speed. An additional third speed (purge) isavailable using a second switched live connection.An acoustic lining is included as standard, ensuringminimum noise levels.The new potentiometer controlled speed selectorallows accurate setting of airflow, ensuring exactlythe right ventilation rate. This feature also reducesnoise, and energy consumption.Sound LevelsPublished dB(A) figures are free field sound levelsat 3m with spherical propagation at a referencelevel of 2 x 10 –5 Pa. The free field sound powerlevel spectra figures are dB with reference of10 –12 Watts.PerformanceMVDC-MSH features an integral humidistat which triggers the unit to boost when humidity levels in the ductsystem exceed 70%Pa 400Static Pressure350300250200150100500MINMAX0 50 100 150 200 250 300 350 400 450 m 3 /h0 10 20 30 40 50 60 70 80 90 100 110 120 l/sVolumeInfinitely variable performanceMinCasing Breakout Inlet Duct FID Power Casing Breakout Inlet Duct FID PowerModel dB(A) @ 3m dB(A) l/s Watts dB(A) @ 3m dB(A) l/s WattsMaxMVDC-MS 19 18 21 6 37 38 123 45MCDC-MSH 19 18 21 6 37 38 123 45W: www.vent-axia.com 61


Lo-CarbonPoziDryPositive Pressure UnitFeatures & Benefits Selectable air capacities to suit floor area upto 150m 2 Uses latest Lo-Carbon technology motor forlow running costs Ultra Low sound level Lo-Carbon PoziDry comes complete withceiling diffuser, flexible duct, worm drive clipsand anti-vibration mounts Standard 5 year guarantee Up to 5 year maintenance free EU4 filter IPX2 SFP of 022W/l/sPositive Pressure <strong>Vent</strong>ilationFor controlling condensation particularly in therefurbishment sector, the <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon PoziDryoffers a quick and simple solution. A loft mountedpositive input fan draws fresh air from atmosphere,filters it and pushes it into the dwelling via a ceilingmounted diffuser. Stale air in the property is forcedout through the natural forms of ventilation, such aswindow mounted trickle vents.Without heaterCASStock Ref£ Trade444075 335.72With integral heaterCASStock Ref£ Trade444766 358.87InstallationIt is simply installed, out of sight in the loft space. It canbe suspended from a roof beam or be floor mounted,with a purpose-designed diffuser normally locatedover the stairwell of a conventional two story dwellingor in the main hall of a bungalow. The Lo-CarbonPoziDry is set to the appropriate speed at installationbased on the size of the dwelling, providing positivepressure input ventilation. Background ventilationopenings provide the exhaust points.PerformanceThe robust construction of the Lo-Carbon PoziDryfeatures a specially developed Lo-Carbon DC fan/motor arrangement which runs quietly and deliversincredibly low running costs. The Lo-Carbon PoziDryuses a sensor to monitor the temperature in theloft, automatically adjusting the air volume whennecessary. ‘Trickle’ speed is automatically selectedwhen the ambient loft temperature is up to 18°C.‘Normal’ is automatically selected when the ambientloft temperature is between 18 and 27°C.If the ambient loft temperature exceeds 27°C, the Lo-Carbon PoziDry will automatically switch to standby(no airflow). The standby power consumption is 2W.In the case of the integral 500W heater version,the heater element is automatically activated whennecessary and tempers the supply air to 10°C. Canbe used for air replacement in conjunction with anextract fan.FilterThe unit includes a filter with up to 5 years maintenanceintervals to reduce the number of call outs neededthroughout its life span.Time Elapsed MeterThe unit includes a time elapsed meter to enableprecise running information.Speed ControlWith selection of 2 of 6 speeds available up to 50l/s,the unit is suitable for houses up to 360m 3 .HeaterAn optional comfort heater is available for operationwhen the incoming air temperature becomes low.Typical SpecificationThe unit should be mounted in the loft space with adiffuser in self-extinguishing ABS positioned at thetop of the stairwell. The unit meets the EMC and lowvoltage directives.The unit includes a filter with up to 5 year maintenanceintervals and an integral time elapse meter.MotorThe electronically controlled DC motor is manufacturedwith long life ball bearings and is fitted with StandardThermal Overload Protection (S.T.O.P.). Suitable forambient operating temperatures of -25˚C to +40˚C.For complete peace of mind, the <strong>Vent</strong>-<strong>Axia</strong> Lo-CarbonPoziDry is backed by a 5 year guarantee.Twin Spigot KitStock Ref£ Trade449071 GEN 49.99Includes:1 x 436592 (200mm Duct) BAS 68.122 x 561707 (Worm Clips) GEN 3.051 x 452085 (200mm equal Y Piece) GEN 40.461 x 10544200 (Diffuser) GEN 29.8862 T: 0844 856 0590


dMEV, MEV & PIV SystemsDimensions (mm)ABDCA B (depth) C Weight438 411 379 11.5kgPerformanceSpeed 1 2 3 4 5 6FID (l/s) 10 18 26 34 42 50Power (W)* 2.5 3 4 5 7 13Floor Area up to (m 2 ) 30 54 78 102 126 150dB(A) @ 3m 19 23*add 500W for heater versionSound DataOctave band, Hz, dB SWLSPLSetting Test mode 63 125 250 500 1k 2k 4k 8k dB(A) at 3mSupply 33.2 28.3 25.4 15.3 17.2 12.6 16.4 22.7 8.5Speed 1Breakout/Intake 36.7 25.3 26.9 16.1 28.6 30.4 18.4 23.8 13.5Supply 65.2 57.2 60.8 67.6 62.2 59.7 50.8 41.2 19.0Speed 6Breakout/Intake 39.7 37.0 43.9 41.1 37.6 32.5 27.1 26.1 22.0W: www.vent-axia.com 63


Lo-CarbonPoziDry CompactPositive Pressure UnitFeatures & Benefits Ultra low sound level Selectable air capacities to suit volumes ofup to 34 l/s or floor area up to 100m 2 Extremely low running costs - from less thanone pence per day Washable, high capacity filter Round to rectangular duct adaptorincluded 5 Year Guarantee Ideal for flatsPositive Pressure <strong>Vent</strong>ilationFor those properties that do not have a loft, Lo-CarbonPoziDry Compact provides an easy to install solution.A duct mounted unit that can be fitted in a number oflocations around a single floor flat or apartment.Air is drawn into the Lo-Carbon PoziDry Compact unitvia an external inlet and through a short length of duct.The specially developed fan/motor assembly (usingthe Lo-Carbon DC motor technology) draws the airthrough an integral, high capacity, washable filter.The backward curved impeller guarantees increasedefficiency, lower sound levels and better performance.The fresh, filtered airflow passes along the ducting andterminates on an internal wall with a discreet grille. Thisdirects the airflow upwards where the incoming airmixes with the warm air that gathers at ceiling height.Without heaterCASStock Ref£ Trade444076 410.96With integral heaterCASStock Ref£ Trade444767 434.11PerformanceThe Lo-Carbon PoziDry uses a sensor to monitor thetemperature in the loft, automatically adjusting the airvolume when necessary.‘Trickle’ speed is automatically selected when theambient loft temperature is up to 18°C.‘Normal’ is automatically selected when the ambienttemperature is between 18 and 27°C.If the ambient loft temperature exceeds 27’C, theLo-Carbon PoziDry will automatically switch to standby(no airflow). The standby power consumption is 2W.In the case of the integral 500W heater version,the heater element is automatically activated whennecessary and tempers the supply air to 10°C.Air Replacement Grille SetFor air replacement through doors. Consists of a twopiecetelescopic set, which fits unobtrusively on eitherside of the door panel. Minimum fixing thickness30mm. Plastic. Dimensions: 454 x 90mm.Duct Adaptor (included)Dimensions (mm)BCAA B Ø C180 105 55 x 110The system automatically provides fresh, temperedairflow into the home. Creating an environment wherethe damaging effects of condensation find it hard toexist, benefits both the occupants and the structure ofthe home.Can be used for air replacement in conjunction with anextract fan. EU4 filter as standard.Installation PacksCASStock Ref No. 453546 453547 453548£Trade 42.95 56.82 61.59Quick Fit Grille (White) 1 1 1Wall fitting kit (Brown) 1 1 1HR 70WH Rdn-Rect Ad 1 3 3HR 060WH Vert 90° bend 2 2 2Ind 040WH Elbow/Spgt 1 1 1HR 010WH 1m Flat Chnl 1 2 2HR 015WH 1.5m Flat Chnl 1 2 2HR 020WH Connector 1 4 4HR 050WH Horiz 90° Bend - - 2HR 122-H Chnl Clip 4 6 264 T: 0844 856 0590


dMEV, MEV & PIV SystemsDimensions (mm)ADBCA B C D E F G Weight435 365 490 100 160 58 160 7kgEGFRear duct entry optionPerformanceSpeed 1 2 3 4FID (l/s) 10 18 26 34Power (W)* 5.7 12.2 24.6 49.8Floor Area (m 2 ) 30 54 78 100*add 500W for heater versionSound DataOctave band, Hz, dB SWLSPL dB(A)Setting Test mode 63 125 250 500 1k 2k 4k 8k @ 3mSupply 37.6 32.7 33.4 35.0 29.8 27.5 18.2 22.6 18.0Speed 1 Extract 37.0 32.3 32.5 32.4 21.9 25.3 16.8 22.6 15.5Breakout 35.3 46.9 38.8 33.1 22.9 22.2 17.8 23.3 15.0Supply 65.2 57.2 60.8 67.6 62.2 59.7 50.8 41.2 50.0Speed 4 Extract 60.8 51.7 58.5 62.1 56.1 56.4 45.2 37.9 45.5Breakout 57.2 55.2 55.5 63.3 55.1 52.2 44.1 32.9 41.5W: www.vent-axia.com 65


Residential &CommercialSingle Room dMVHRImproving air quality on a room-by-room basis,the <strong>Vent</strong>-<strong>Axia</strong> through-the-wall mounted rangeof heat recovery ventilation units simultaneouslyextract stale air and introduce fresh air – warmingthe incoming air flow with heat recovered fromthe exhaust stream.Lo-Carbon TempraThe <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon Tempra through-the-wall heat recovery units are suitable for fittingthrough a 100mm (4”) circular hole, ideal forrefurbishment and are designed for use inbathrooms, toilets, utility rooms and kitchens.Meets current Building Regulations ApprovedDocuments F and L.Range66 T: 0844 856 0590


W: www.vent-axia.com 67


Lo-CarbonTempra/SELVSingle Room Heat Recovery UnitFeatures & Benefits Fits in 100mm diameter hole – ideal forrefurbishments 78% heat recovery Reduces the home’s carbon footprint Choice of control options Suitable for refurbishment Summer setting Helps prevent noise ingress Continuous running or intermittent extract Meets current Building RegulationsApproved Documents F and L Low SFP of 0.3W/l/s IPX4 ratedThrough-The-Wall Mounted HeatRecovery UnitThe <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon Tempra is designedto fit in 100mm diameter hole and is suitable forrefurbishment, kitchen, bathroom, toilet or utilityapplications. The unit meets the performancerequirements for continuous extract fans under thecurrent Building Regulations Approved Document F.The Tempra is available in three models, a P versionwith pullcord control, a T version with overrun timerand an HTP version with built-in pullcord, overrun timerand humidistat.Typical InstallationThe unique heat exchanger design allows the Temprato be fitted in a 100mm diameter hole, allowing it toreplace standard 100mm extract fans while giving allthe benefits of heat recovery. Maximum wall thicknessis 320mm.ModelsLo-Carbon Tempra P (Pullcord)CASConstant trickle speed with pullcord to boost orintermittent operation by pullcord.Model Stock Ref £ TradeP 443312 150.50SELV P 444368 186.88Lo-Carbon Tempra TCAS(Timer)Constant trickle speed with switch live to boost orintermittent operation by switch live.Model Stock Ref £ TradeT 443310 196.80SELV T 444369 222.16Heat Exchange (what is heat recovery?)Lo-Carbon Tempra HTP(Humidistat/Timer/Pullcord)CASConstant trickle speed with humidistat and linkedoverrun timer to boost or intermittent operation byswitch live.Model Stock Ref £ TradeHTP 443311 228.05SELV HTP 444370 253.41100mm High Rise Kit - 320mm white duct withblack sealDOMStock Ref£ Trade449011 26.32The manual summer setting allows the unit to be set toextract only, helping to prevent a dwelling becomingtoo warm in hot summer conditions.PerformanceTempra can be set to run continuously at 6 l/s or 9 l/s,boosting up to 15 l/s, recovering heat from extractedair and returning it to the dwelling. The unique,compact heat exchanger has a temperature efficiencyup to 80%, saving energy and reducing your carbonfootprint. For intermittent extract the Tempra is setto 15 l/s.StaleWarm airfrom dwellingFreshWarmed airreturned todwellingFreshCold air inStaleCoolair outThe Lo-Carbon ECDC motor with twin impellersconsumes as little as 3.2 Watts on trickle rate and runsalmost silently at only 20dB(A).68 T: 0844 856 0590


Single Room dMVHRWINNER2011Winners of the Energy Efficiency Initiative 2011 Awardwith our Lo-Carbon Continuous <strong>Vent</strong>ilation <strong>Product</strong> Range.Dimensions (mm)PerformanceExtract Performance l/s Power Consumption Watts Sound @dB(A)Model Stock ref Trickle Low Trickle High Boost Trickle Low Trickle High Boost Trickle Low Trickle High BoostLo-Carbon Tempra P/SELV P 443312/444368 6 9 15 3.2 5.7 26.6 20 22 36Lo-Carbon Tempra T/SELV T 443310/444369 6 9 15 3.2 5.7 26.6 20 22 36Lo-Carbon Tempra HTP/SELV HTP 443311/444370 6 9 15 3.2 5.7 26.6 20 22 36*Octave band frequency range of 250Hz to 4KHz at 3m. Unit mounted on a reflective surface.W: www.vent-axia.com 69


Single Room dMVHRLo-CarbonHR25 Solo® PlusSingle Room HeatRecovery UnitFeatures & Benefits Reduces the home’s carbon footprint 84% temperature based heat recovery Up to 90% energy saving IP24 rated Controls condensation and eliminatesmould Long life DC motors Installation can be carried out from withinthe buildingThrough-The-Wall Mounted HeatRecovery UnitThe <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon HR25 Solo Plus throughthe-wallheat recovery units are suitable forfitting through a 152mm (6”) circular hole andare designed for use in bathrooms, toilets andutility areas.The <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon HR25 Solo Plus isavailable with pullcord control.Long Life DC MotorThe units are fitted with a 24V DC motor and aresupplied with a state of the art Switch Mode PowerSupply (S.M.P.S.). This has the ability to operate atonly 2 Watts power consumption on normal setting,offering a 90% energy saving over conventional ACequivalents. A 5m cable is provided for fixed wiringof the unit to the S.M.P.S.PerformanceTypical InstallationThe Lo-Carbon HR25 Solo Plus P (Pullcord) unitis designed for installation in a 152mm (6”) coredrilled hole. All installation can be carried out frominside the building. The units are suitable for externalwalls up to 310mm thick.MaintenanceApart from removing odours, providing fresh air andrecovering heat, this appliance extracts airborneimpurities such as dust, dirt and grease. Thesegradually build up and detract from the efficiencyand appearance of the appliance. To ensure peakperformance, the appliance, including the filtersand heat exchanger should be cleaned regularly inaccordance with the instructions supplied.ModelLo-Carbon HR25 Solo Plus PDOMThe HR25 Solo Plus P is fitted with a pullcord switchwhich operates the twin speed control function.Stock Ref£ Trade434036 267.94Filters (pack of 2)SPStock Ref£ Trade435740 3.58Dimensions i (mm)A B C DØ E F G505 447 327 147 58 208 253Weight 3kgTop ProfileABECDØFSide ProfileGFixing hole Ø 152mmExtract Performance Intake Performance Soundm 3 /h (l/s) m 3 /h (l/s) Watts dB(A) @ 3m*Model Boost Trickle Boost Trickle Boost Trickle Boost TrickleLo-Carbon HR25Solo Plus P39.6 (11) 10.8 (3) 43.2 (12) 4.7 (1.3) 23 2 49.2 16.8*Octave band frequency range of 250Hz to 4KHz at 3m. Unit mounted on a reflective surface.70 T: 0844 856 0590


Single Room dMVHRLo-CarbonHR25Single Room HeatRecovery UnitFeatures & Benefits Reduces the home’s carbon footprint Designed for installations in bathrooms,toilets and utility areas 84% temperature based heat recovery Up to 90% energy saving Controls condensation and eliminatesmould Choice of control options Long life DC motors IP24 ratedLong Life <strong>Vent</strong>ilationThe <strong>Vent</strong>-<strong>Axia</strong> Lo-Carbon HR25 range of throughthe-wallheat recovery units are suitable for fittingthrough a 152mm (6”) circular hole and aredesigned for use in bathrooms. Available in 2 lengths,a standard version suitable for wall thicknesses ofup to 310mm and an extended version suitable forwall thicknesses of up to 425mm. The <strong>Vent</strong>-<strong>Axia</strong>Lo-Carbon HR25 is available in 2 models, astandard version with pullcord control and a Hversion with an integral humidity sensor.PerformanceThe units are fitted with a 24V DC motor and aresupplied with a state of the art Switch Mode PowerSupply (S.M.P.S.). This has the ability to operate atonly 2 Watts power consumption on normal setting.A 5m cable is provided for fixed wiring of the unitto the S.M.P.S.MaintenanceApart from removing odours, providing freshair and recovering heat, this appliance extractsairborne impurities such as dust, dirt and grease.Filters should be replaced every six months or asconditions necessitate.ModelsLo-Carbon HR25DOMThe HR25 is fitted with a pullcord switch whichoperates the twin speed control function.Stock Ref£ Trade372261 243.61Lo-Carbon HR25HDOMThe HR25H is fitted with an adjustable humiditysensor which automatically switches between itshigh and low settings depending on the relativehumidity in the room.Stock Ref£ Trade372262 268.87Lo-Carbon HR25LDOMAn extended version of the HR25 is available,designed for installations where the wall thicknessis between 311mm and 425mm.Stock Ref£ Trade372264 268.87Lo-Carbon HR25LHDOMAn extended version of the HR25H is available,designed for installations where the wall thicknessis between 311mm and 425mm.Stock Ref£ Trade372265 268.87Dimensions (mm)A B C D E FStandard 508 451 318 147 204 54Long 666 548 433 147 204 54Standard - Weight 3.4kgLong - Weight 3.5kgTop ProfileDØABCEFSide ProfileFixing hole Ø 152mmPerformanceExtract Performance Intake Performance Soundm 3 /h (l/s) m 3 /h (l/s) Watts dB(A) @ 3m*Model Boost Trickle Boost Trickle Boost Trickle Boost TrickleHR25 55 (15) 20 (5) 36 (10) 8 (2) 23 2 49.2 16.8HR25H 55 (15) 20 (5) 36 (10) 8 (2) 23 2 49.2 16.8HR25L 55 (15) 20 (5) 36 (10) 8 (2) 23 2 49.2 16.8HR25LH 55 (15) 20 (5) 36 (10) 8 (2) 23 2 49.2 16.8*Octave band frequency range of 250Hz to 4KHz at 3m. Unit mounted on a reflective surface.GW: www.vent-axia.com 71


Single Room dMVHRHR200WKSingle Room HeatRecovery UnitFeatures & Benefits Single room domestic heat recoveryventilation unit 3 speed motor Integral washable filter Up to 75% heat recovery Saves energy - controls condensation Low noiseHeat Recovery <strong>Vent</strong>ilationThe <strong>Vent</strong>-<strong>Axia</strong> HR200WK is a heat recoveryventilation unit specifically designed for use indomestic kitchens and utility rooms to meet theBuilding Regulations. The unit is also suitable for lightcommercial requirements up to 220m 3 /h (50l/s).The compact, self contained unit is designed forthrough wall mounting.The three speed, external rotor motor has twomatched impellers to ensure a controlled air flowthrough the unit, with exceptionally economical 25watt low speed power consumption.Easy InstallationThe HR200WK fits through walls up to 335mmthick requiring a fixing hole 250mm square. Theinternal grille has washable, polymeric foam supplyand extract filters. Only the neat internal twin grillevisible from the room. A wall extension sleeve isavailable for walls up to 550mm thick.Heat ExchangerThe highly efficient, polymeric heat exchangercube is washable. The compact cube interleavesoutgoing moist warm air with incoming fresh air andallows the heat from one to warm the other withoutthe two air streams mixing. Up to 75% of the heat,which would otherwise be lost, is transferred to theintake air, ensuring energy saving ventilation.ElectricalHR200WK 220-240V/1/50Hz Class 1 earthedappliance. The 3 speed motor, can be wired tooperate On/Off for any one of the three speeds.Alternatively, an Ambient Response HumiditySensor or simple changeover switch can be usedto provide switching between any two speeds,giving permanent trickle ventilation and automaticchangeover to a higher speed during periodsof high moisture generation. Also the 3 speedcontroller enables the unit to be switched frompermanent trickle to either medium or boost speed.Extension Wall SleeveGENStock Ref£ Trade370421 69.05Electronic ControllerGENStock Ref£ TradeW300310 80.49ModelsHR200WKDOMA heat recovery unit specifically designed for usein domestic kitchens and utility rooms to meet thelatest building regulations. 3 speed motor, trickleventilation mode, optional range of switchesavailable.Stock Ref£ Trade14120020 436.68HR200WK ControllerDOMA three position rotary control which enables the unitto be switched from permanent trickle ventilation toeither medium or boost speed.Stock Ref£ Trade563533 32.97Dimensions (mm)A B C D E F270 270 245 85 68min 335maxWeight 9.7kgWall fixing hole 250mm x 250mm sq.PerformancePerformance m 3 /h (l/s) % Sound dB(A)Extract Intake Watts Heat Recovery @ 3mSpeed 1 60 (16) 50 (13) 25 75 19Speed 2 110 (30) 100 (27) 60 70 33Speed 3 220 (61) 200 (55) 140 65 4672 T: 0844 856 0590


Single Room dMVHRHR300Single Room HeatRecovery UnitFeatures & Benefits Designed for continuous operation,providing up to 70% heat recovery Controls condensation and eliminatesmould Speed controllable Quiet operation Washable filtersHeat Recovery <strong>Vent</strong>ilationThe HR300 provides ventilation with heat recovery.It is ideal for light commercial applications includingfunction rooms, offices, classrooms etc. The HR300unit comes complete with an integral shutter.PerformanceThe HR300 unit is designed for continuous operationproviding up to 70% heat recovery. Effectivelylowering internal relative humidity the HR300 unitcontrols condensation and eliminates mould.Fresh, pre-warmed air from outside is continuallyprovided to the room with simultaneous extractionof stale moist air and smells. Heat is transferred viaa unique plastic heat exchanger from outgoing airto the fresh air supply with no cross contamination,maintaining internal temperatures and providing afresh environment.The unit is fully controllable for speed using a smalldedicated speed controller. Automatic ON/OFFcontrol or switching to boost is easily achievedusing sensors/timers e.g. humidistat. For summeroperation the heat exchanger can be removed andreplaced with a plastic divider board to providepositive cooling to rooms.InstallationThe HR300 unit requires a 380mm x 280mm hole.Units should be level and square in the wall. Theunit should be fitted so that it overhangs by minimumof 50mm on the inside, and a minimum of 70mmon the outside. An extension sleeve is available forwalls up to 650mm thick.MaintenanceFilters should be cleaned by washing every sixmonths or as conditions necessitate. Replacementfilters can be purchased in packs of twoFiltersSPStock Ref£ Trade370402 6.05Extension SleeveDOMStock Ref£ Trade370422 38.17Electronic ControllerGENStock Ref£ TradeW300310 80.49VCON6 ControllerGENStock Ref£ Trade370356 48.12The heat exchanger should be washed in warmsoapy water every twelve months, or as conditionsnecessitate. Access to the filter and heat exchangeris via two screws on the internal grille.ModelsHR300DOMStock Ref£ Trade370394 398.92Dimensions (mm)A B C370 270 400Weight 11kgBACPerformanceExtract Performance m 3 /h (l/s) Intake Performance m 3 /h (l/s) Max Sound dB(A) @ 3mModel Low Normal Boost Low Normal Boost Watts Low Normal BoostHR300 75 (20) 210 (58) 300 (83) 70 (19) 190 (52) 270 (75) 108 37 40 44W: www.vent-axia.com 73


MVHR units forresidential &commercial applicationsA complete range of MVHR units for a rangeof residential and commercial applications,including many that are SAP Q Eligible.New Sentinel Kinetic ®The first of our new generation of MVHRsystems incorporating a range of new features.Small enough to fit into a kitchen cupboard withintegrated digital controls for easy installationit is designed with installers in mind. With90% efficiency and low specific fan powersdesigners will also see a reduction in theirdwelling emission rate.Single Room Heat RecoveryHR500 heat recovery ventilation units forthrough wall installation, which exhaust staleair whilst introducing warmed fresh air from theoutside.Ideal for computer rooms, classrooms, officesand the health and leisure industries. The<strong>Vent</strong>-<strong>Axia</strong> HR500 unit is the perfect solutionto commercial areas that require a highperformance balanced intake/extract scheme.As a heat recovery ventilation unit it moves auseful 150l/s of air.Range74 T: 0844 856 0590


W: www.vent-axia.com 75


Lo-CarbonKinetic® RangeMechanical <strong>Vent</strong>ilation with Heat RecoveryModel RangeOveriewModel RangesLo-Carbon SentinelKinetic PlusLo-Carbon SentinelKinetic Cooker HoodLo-CarbonSentinel KineticLo-CarbonSentinel Kinetic HorizontalLo-CarbonKinetic Plus ELo-CarbonKinetic EModels Plus C CH V B BH 300Z 300ZH 200Z 200ZH Plus E EAuto Summer Bypass Easy Access Filters Very Low Noise Levels Integral Cooker Hood Built-In Humidistat Kitchen Cupboard Inst’n Max Airflow @ 100Pa 117 68 68 68 68 68 81 81 34 34 117 36Frost Protection Delay-On Wired Remote Control O O O O O O Wireless Boost O O O O O O O O O OClean Filter Indicator (Time) Fault Code Indicator Potentiometer control Sentinel Control Switched Live No Volt Contact 0V - 10V Proportional Control BMS Input/Output 1 1 1 1 1 1 1 1 1 1Light Weight External Condensate Horizontal Duct Option Horizontal (Slab) Installation Left/Right Orientation <strong>Vent</strong>-Wise Control PIN Number Lock Running time indicator Mounting OptionsWall Surface Wall Wall Surface Slab Wall Surface Wall Surface0 - Denote Optional, 1- Seek technical advice from <strong>Vent</strong>-<strong>Axia</strong>76 T: 0844 856 0590


MVHR UnitsELIGIBLE FORSAP APPENDIX QDemand ControlThe Lo-Carbon Kinetic Range can be used with a wide range of <strong>Vent</strong>-<strong>Axia</strong> controllers and sensors. Ranging from integral humidistats, through wireless controllersto wired remote sensors.Integral HumidistatCAS Simple Plug-n-Play installation Eliminates the need for additional controllers or sensors Reacts to any rapid increases in relative humidity orrelative humidity above 60% Future proof – can be fitted after installation Self programmingStock Ref.£ Trade437598 36.81Ambient Response Humidity SensorGEN Pullcord override and neon indicator Changeover relay switch Operating range: 30% - 90%RH Ambient operating temp. 5°C to 40°C 220-240V AC Will fit single gang box for surface mountingStock Ref.£ Trade563550 162.30Visonex PIR SensorGEN Fits any UK single gang mounting box Adjustable timer overrun (5-25 mins) Range of detection up to 10 metres Designed to meet IP43 Ambient operating temp. range 0°C to 50°CStock Ref.£ Trade459623 91.72Wireless Transmitter ControllerCASReceiver Kit Manual boost Adjustable overrun timer Easy wire-less installation Reduces installation time Future proof - add more controllers at any timeStock Ref.£ Trade439352 73.63Ecotronic Humidity SensorGEN Set Point adjustable Maximum switching load 1 amp inductive Pullcord override indicator Ambient operating temp. 0°C to 40°C Supply voltage 220-240VStock Ref.£ Trade563532 88.44CO 2+ Temp Room SensorIND 240V DC 0 - 2000ppm CO 2working range. 0 - 50°C working range Auto-calibrating NDIR CO 2absorption sensor Thin film platinum temperature sensor for high accuracyStock Ref.£ Trade433257 475.38Wireless Transmitter ControllerCAS Additional controller for 439352 A maximum of 4 controllers can be used per system Can be connected to other accessories (eg Humidistat)to send a boost signal wirelesslyStock Ref.£ Trade437827 42.96Air Quality SensorGEN Ambient operating temp. 0°C to 50° Min - Max mode or direct damper control Surface mounted 1 - 25 min O/R timer Supply voltage 220-240VStock Ref.£ Trade563506 177.37<strong>Vent</strong>wiseCAS Automatically boosts fan when temperature of thesupply pipe to a shower or bath increases Automatically boosts fan when electric hob is switchedon Can be used in conjunction with manual override input Adjustable overrun timer Two sensor options available.Stock Ref.£ Trade435960 316.06W: www.vent-axia.com 77


Lo-CarbonSentinel Kinetic® RangeMechanical <strong>Vent</strong>ilation with Heat RecoveryFeatures & Benefits Manufactured in the UK Building Regulations ADF compliant SAP Appendix Q Eligible Up to 94% heat recovery whilst controllingcondensation Programmable Summer bypass Horizontal and/or vertical duct outlets Integrated digital controller for simple andaccurate commissioning Light-weight for easy installation External condensate connection Plug and play controls; Humidistat,<strong>Vent</strong>-Wise, Wireless remote BMS connectivity LS inputs/(Light Switch) Volt-free inputs Self diagnosis for simplified fault finding Adjustable delay on/delay off timerThe Sentinel Kinetic Rangeincorporates:A wholehouse heat recovery system with up to94% energy efficiency. An easily accessible heatrecovery cube protected by two removable EU3filters. Two Lo-Carbon Energy Saving EC DC fansensure long life (typically over double the life ofAC motors) and lowest possible energy use. Fullyinsulated construction with built in condensationdrain. Specifically designed for new buildconstructions with a high level of insulation.Lo-Carbon Sentinel Kinetic meets the latestrequirements of the Building Regulations ApprovedDocument F for wholehouse system ventilation:System 4. Continuous mechanical supply andextract with heat recovery. The Lo-Carbon SentinelKinetic models have 3 fully adjustable speeds anda purge setting - maximum. Provided with the unitis a digital controller that can be used to presetthe speeds to any required air-flow within theperformance range.Integral Humidity sensorThe integral humidity (models with H suffix) sensorincreases speed in proportion to relative humiditylevels, saving energy and reducing noise. Thesensor also reacts to small but rapid increases inhumidity, even if the normal trigger threshold is notreached. This unique feature ensures adequateventilation, even for the smallest wet-room. Nighttime relative humidity setback feature suppressesnuisance tripping as humidity gradually increaseswith falling temperature.78 T: 0844 856 0590


MVHR UnitsELIGIBLE FORSAP APPENDIX QOptional F5 supply filtersKinetic V FilterStock Ref£Trade444199 18.33Kinetic B, BH & Cooker Hoods FilterStock Ref£Trade444200 18.33Kinetic Plus range FilterStock Ref£Trade444201 27.76For sensors see Accessories & Controllers section.Sentinel ControlThe Sentinel controller is the most advanced systemavailable, providing Demand Control <strong>Vent</strong>ilation(DCV), minimising energy consumption and noiselevels, and optimising ventilation performance.Sentinel controlled units may be set to operatefully automatically or with varying levels of manualintervention.BMS (Building Management System) OptionsThere are two levels of BMS available: BasicOutput and full Electronic BMS.Basic Output provides a 5 volt output from theLED terminals on the controller. This output occurswhenever a message appears in the digital display,for example; ‘Check Filters’ or a fault code. Theoutput can also be converted to volt-free with theaddition of an optional Opto-Coupler.Electronic BMS: A full range of two-way digitalsignals are available through the RJ11 connectoron the control board. The BMS system providerwill translate this signal to extract the desireddata. Contact <strong>Vent</strong>-<strong>Axia</strong> to discuss your specificrequirements.LED AlarmMVHR units are often installed in lofts or otherlocations where they are difficult to monitor. Theoptional remote LED alarm illuminates when anymessage is visible in the MVHR unit display panel.The LED alarm can be installed in a convenientlocation within the dwelling allowing end users tosee that the unit requires attention.SPControl InputsFive Volt-free pairs of switch terminals for sensorinputs allow boosting from a full range of <strong>Vent</strong>-<strong>Axia</strong>controllers – humidistats, PIR, timers.Two terminals with 0-24V outputs allow 0V to 10Vproportional control by sophisticated controllerssuch as CO 2sensors and proportional humidistats.The optional <strong>Vent</strong>-Wise controller sensestemperature rise in a bath/shower hot water supplyand/or current in a cooker/hob electrical circuit toactivate boost, ensuring additional ventilation whenneeded.Switched-live for boosting via light switches (220-240 V AC) or manual Normal/Boost switches. Thisconnection has the advantage of Delay-On andDelay-Off facility. Delay-On enables you to preventthe Boost airflow between 0 and 10 minutes, aftera light switch has been activated. Delay-Off allowsthe Boost airflow to continue after a light switch isturned off to ensure effective clearance of humidity.This timer is adjustable between 0 and 25 minutes.Optional ControlsCASLED Alarm with 15 metre cableStock Ref£Trade448356 25.00Wired Remote Controller with 15 metre cableStock Ref£Trade443283 46.31Wireless enable Kit (includes one switch)Stock Ref£Trade441865 69.46Additional wireless boost switch(max 3 switches)Stock Ref£Trade437827 42.96<strong>Vent</strong>-Wise Controller (also requires sensors, seeAccessories & Controllers section)Stock Ref£Trade441780 156.28Purge settingThe unit can be set to maximum flow (100%) bypressing and holding the Boost button on the unititself or optional wired controller for 5 seconds.Purge will continue for two hours unless cancelledby pressing the Boost button again.Summer BypassAn internal damper is activated when the outsidetemperature is less than the room temperature.The damper opens allowing cooler fresh air tobypass the Heat Recovery Cell and reduce theinternal temperature towards the preset ‘ComfortTemperature’. When the inside air temperaturereaches the pre set ‘Comfort Temperature’ thebypass damper closes. Anti-frost protection: In coldclimates there is a possibility of frost building up onthe intake side of the heat exchanger. In order toprevent damage, the Kinetic reduces supply flowwhile maintaining extract flow at temperaturesbelow 0˚C.System Cooker Hood RangeSystem canopy hoods are a motorless hood withextract being provided by the MVHR unit. When theboost button on the canopy is activated, the MVHRunit goes to boost setting and the summer bypassopens preventing cooking by-products entering theheat exchanger cell.Wired Remote ControllerStandard with horizontal units,optional extra with verticalunits. Supplied with 15 metresof cable (max length), theWired Remote Controllerduplicates all the features of theon-board control panel,allowing commissioning, diagnosis and user control.Flush mounting, suitable for a single gang patrassbox 16mm deep.W: www.vent-axia.com 79


Lo-CarbonSentinel Kinetic® PlusMVHR UnitFeatures & Benefits SAP Appendix Q eligible Ultra quiet Horizontal duct option for space-savinginstallations High airflow and ideal for studentaccommodation clusters Unique folding filter for removal when accessis restricted Integrated digital controller for simple andaccurate commissioning Light-weight for easy installation Plug and play controls; Humidistat, <strong>Vent</strong>-Wise,Wireless remote BMS connectivity LS inputs/(Light Switch) Volt-free inputs Self diagnosis for simplified fault finding Adjustable delay on/delay off timerIncreased PerformanceThe Kinetic Plus benefits from the latest high efficiency,backward curved impeller design, ensuring the lowestpossible energy consumption, ultra quiet operation andan exceptional performance range covering small onebed apartments to the largest of houses.Care Homes & Student AccommodationThe Kinetic Plus is ideal for larger homes and multipleoccupancy units such as nursing homes and studentaccommodation. Capable of 400m 3 /hr at 150Pa,the unit can extract from up to ten bathrooms and acommunal kitchen while still achieving almost 90% heatrecovery. The fully automatic capability of the Kineticrange means that adequate ventilation is alwaysachieved.The Kinetic’s BMS capability is also ideal for thesecommercial applications where landlords or propertymanagers want to monitor and optimise buildingperformance and maintenance. The Kinetic BMS canprovide status information and it’s self diagnostics canreport if any fault is found.Spigot OptionsIn addition to horizontal and vertical spigot positions,the Kinetic Plus has 150mm spigot connections asstandard with the option of 180mm or 200mm spigotconnections. In installations where very high airflowsare expected, the larger spigots can reduce resistance,lowering noise and energy consumption.180mm/200mm spigots can simplify connection incommercial installations where larger diameter ductwork has been used.Quick Change filterAs many systems are placed within cupboards theunique filter design folds as you remove it to ensureeasy access in restricted spaces.Integral Humidity sensorThe integral humidity sensor increases speed inproportion to relative humidity levels, saving energyand reducing noise. The sensor also reacts to small butrapid increases in humidity, even if the normal triggerthreshold is not reached. This unique feature ensuresadequate ventilation, even for the smallest wet-room.Night time relative humidity setback feature suppressesnuisance tripping as humidity gradually increases withfalling temperature.ModelsCASModel Stock Ref £ TradeKinetic Plus B 443028 1360.21AccessoriesCASModel Stock Ref £ TradeWired remote controller 443283 46.31Wireless enable kit 441865 69.46<strong>Vent</strong>-Wise Controller 441780 156.28LED alarm with 15m Cable 448356 25.00Opto-Coupler 447340 30.00For volt-free BMS connectionSPModel Stock Ref £ TradeKinetic Spare Filters 2 pk. 443351 29.14F 5 pollen filter 444201 27.76Dimensions (mm)A B C D EØ F G785 632 722 526 150 520 275AFDGEØSAP Appendix Q PerformanceSpecific Fan ThermalPower (W/l/s) EfficiencyK+1 0.56 92%K+2 0.49 92%K+3 0.52 91%K+4 0.57 90%K+5 0.62 90%K+6 0.70 89%K+7 0.80 89%BC80 T: 0844 856 0590


MVHR UnitsELIGIBLE FORSAP APPENDIX QPerformanceFan speeds are fully adjustable within the performance range700600x wattage (both motors)Example system curvesStatic Pressure (Pa)500400300140 1731472008386100423321 190Volume (l/s) 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140Volume (m3/hr) 0 50 100 150 200 250 300 350 400 450 500Sound DataOctave band, Hz, dB SWLSPL dB(A)Flow, l/s Unit setting Test mode 63 125 250 500 1k 2k 4k 8k at 3mSupply 46.5 54.3 46.4 44.8 36.2 28.5 24.5 31.2 28.550 20% Extract 46 52.2 42.3 38.7 27.6 24.2 24 31.7 25Breakout 48.5 42.6 43.3 38.9 35.8 29.3 23.8 30.7 22.8Supply 50.3 59.1 54.5 56.5 47 39.9 26.3 31.7 3878 40% Extract 46.8 51.6 47.8 44.4 32.7 27.4 24.4 31.7 28Breakout 48.4 51.2 53.4 46 41 34.6 25 30.3 28.5Supply 52.4 57.2 60.4 60.9 55.8 50.3 33.1 33.9 43.6104 60% Extract 50 49.8 56.8 52.4 40.2 35.9 33.4 39.8 35.2Breakout 55 49.6 59.7 54.5 46.9 39.9 33.6 39.2 34.9Supply 54.9 60.7 67.4 66.6 61.8 56 39.6 37.7 49.5127 80% Extract 50.4 52 61.2 56.6 45.1 39.6 34.2 40.2 39.1Breakout 53.5 53.4 60.8 59.1 53 45.3 36 40.1 38.7Supply 54.7 61.7 70.5 69.9 62.7 57.5 42.1 38.3 52137 100% Extract 54.4 55.1 65.8 57.5 46.9 40.6 33.7 40 41.8Breakout 56.6 54.6 60.5 60.7 54.7 45.9 36.5 39.6 40Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemisphericalW: www.vent-axia.com 81


Lo-Carbon Sentinel® Kinetic PlusConsultants SpecificationOperationThe supply and extract ventilation unit shall be asSentinel Kinetic Plus as manufactured by <strong>Vent</strong>-<strong>Axia</strong>and shall be sized as indicated on the drawingsand shall be in accordance with the particularspecification.Supply air to the room shall be pre-heated by theextract air via the integrated composite plasticcounterflow heat recovery cell. The Sentinel KineticPlus shall automatically vary the ventilation rate viaEC/DC motors, as it receives signals from one ofthe optional interconnected sensors.When a signal is received, the fans shall eithervary their speed proportionally or on a trickle andboost principle.The unit shall have the facility to commission thesupply and extract fans individually via in-builtminimum and maximum speed adjustment, oralternative wired remote control unit. The fansthemselves shall have independent, infinitelyvariable speed control.Unit specificationThe unit shall be manufactured with an ABS Outercase construction, and incorporate a reversiblecore to allow for left or right hand mounting.The unit shall have a high efficiency compositeplastic counterflow heat exchanger, supply andextract filters, automatic summer bypass, integralminimum and maximum infinitely variable speedcontrols with facia mounted failure indication.Standard controlsAll Sentinel Kinetic units shall incorporate thefollowing functions integrally mounted, pre-wiredand factory fitted by the manufacturer: - Integral infinitely variable fan speed controlon supply and extract. Integral min/max ventilation control/set point. Integral BMS input/output interfaces – controland status indication Heating interlocks 0-10V proportional speed adjustment. Volt free contacts 24v sensor supply Integral on/off or trickle boost function fromremote switch, e.g. PIR occupancy detector. Fully automatic summer bypass Switched Live input with adjustable‘delay-on’ feature Fan failure or component failure indicated viaindividual fault code display.Airflow Direction & Condensate Connection (RH Supplied)Supply to dwellingExtract from dwelling Running time counter Control panel PIN number lock Automatic frost protection effective to -20C The unit shall incorporate an integral humiditysensor with the following features: Ambient Response; Raises the humiditytrigger point as dwelling temperaturereduces. Rapid Response: Monitors the rate ofchange in humidity and triggers increasedairflow even if the humidity triggerthreshold is not reached. Proportional Response; Incrementallyincreases the fan speed to reduce noiseand reduce energy consumption. The unit shall be controlled by the ‘Sentinel’control devices (enablers and sensors) asdetailed in the schedule or on the drawings. Tool free filter accessFromatmosphereTo atmosphereThe unit shall have low energy, high efficiencyEC/DC fan/motor assemblies with sealed for lifebearings. The impellers shall be high efficiencybackward curved centrifugal type.The unit shall have a heat exchanger cell with athermal efficiency of up to 92% when tested to EN308. This shall be protected by G3 grade syntheticfilters on supply and extract. Complete with acondensate drip tray and drain connection.The unit shall be constructed with a removable Coreallowing full maintenance access. The removableCore shall provide access to the following: Supply or extract fan Supply and extract filter Heat exchanger Access to the electrical connectionsFilterAccessPanelsControl UnitSpigotBlankingCapsNormalCondensateConnectionAlternativeCondensateConnectionsAccess shall be provided for wiring terminationand setup/ commissioning. The backlit LCD userinterface therein may be duplicated for remotemounting if required. Units shall be as manufacturedby <strong>Vent</strong>-<strong>Axia</strong> Ltd.82 T: 0844 856 0590


MVHR UnitsElectrical ConnectionPlease note: Electrical connection should be carriedout by an appropriately qualified person and inaccordance with current wiring regulations.SETBMS NET J4 3241+ - + - + - + - + - + S - + S - + -S/W1S/W2 S/W3 SW4 S/W5 P1 0-10V P2 0-10V LED L N LS<strong>Vent</strong>-WiseconnectorSwitches 1-5Proportional LEDInputs 1&22m mainscable fittedto unitSwitchedfused spurBrown3ABlackBlueGreen/YellowL N LS E220-240V 50HzTrickle to Boost by two lighting circuits or Trickle/Boost switchW: www.vent-axia.com 83


Lo-CarbonSentinel Kinetic® Cooker HoodMVHR UnitFeatures & Benefits SAP Appendix Q eligible Ultra quiet Horizontal duct option for space-savinginstallations Fits within a 600mm wide aperture (300mmdeep) Integrated digital controller for simple andaccurate commissioning Plug and play controls; Humidistat, <strong>Vent</strong>-Wise, Wireless remote BMS connectivity LS inputs/(Light Switch) Volt-free inputs Self diagnosis for simplified fault finding Adjustable delay on/delay off timerEasy InstallationDucting can be attached to the unit horizontally,vertically or both. Minimum internal depth of kitchencupboard: 300mm.Horizontal and vertical spigots: The combinationof spigot options allows installation in confinedlocations. If vertical and horizontal connection isrequired on the same outlet/inlet, additional spigotscan be supplied.Condensate connection can be taken through therear of the unit or through the side of the unit intoan adjacent cupboard prior to connection into preinstalleddomestic waste water system.Cooker Hood UnitThe Sentinel Kinetic Cooker Hood is designed to fitin a 600mm aperture above a hob. The telescopichood incorporates two flat removable metal greasefilters, low energy light bulbs and is available withWhite or Brushed Aluminium front trim.The hood contains an integral fire damper inaccordance with BRE Digest 398 and is connectedto the heat recovery unit by a galvanised steel ductwith access for cleaning. When the hood is opened,the heat recovery unit goes to boost speed andthe summer bypass automatically opens to preventcooking by-products entering the heat recoverycell. As an additional safety feature, the duct alsocontains a thermal cut-out fuse which turns off theMVHR unit in the event of excessive temperature inthe airway. Cooker Hood units cannot be handedon-site and must be purchased as left hand (L) orright hand (R) models.ModelsCASLo-Carbon Sentinel Kinetic with summer bypass andhumidity sensor.Model Stock Ref £ TradeKinetic CWH L 446756 1453.10(with white Cooker Hood)Kinetic CSH L 446757 1453.10(with Brushed Aluminium Cooker Hood)Kinetic CWH R 446758 1453.10(with white Cooker Hood)Kinetic CSH R 446759 1453.10(with Brushed Aluminium Cooker Hood)Lo-Carbon Sentinel Kinetic with summer bypass.Model Stock Ref £ TradeKinetic CW L 441483 1419.25(with white Cooker Hood)Kinetic CS L 441484 1419.25(with Brushed Aluminium Cooker Hood)Kinetic CW R 441485 1419.25(with white Cooker Hood)Kinetic CS R 441486 1419.25(with Brushed Aluminium Cooker Hood)Integral Humidity sensorThe integral humidity (models with H suffix) sensorincreases speed in proportion to relative humiditylevels, saving energy and reducing noise. Thesensor also reacts to small but rapid increases inhumidity, even if the normal trigger threshold is notreached. This unique feature ensures adequateventilation, even for the smallest wet-room. Nighttime relative humidity setback feature suppressesnuisance tripping as humidity gradually increaseswith falling temperature.AccessoriesCASModel Stock Ref £ TradeWired remote controller 443283 46.31Wireless enable kit 441865 69.46<strong>Vent</strong>-Wise Controller 441780 156.28LED alarm with 15m Cable 448356 25.00Opto-Coupler 447340 30.00For volt-free BMS connectionSPModel Stock Ref £ TradeKinetic Spare Filters 2 pk. 441774 18.33F 5 pollen filter 444200 18.33Dimensions (mm)Weight : 27kgMinimum clearencefrom the bottom ofthis unit to the top ofthe hob must be:Gas: 750mmElectric: 650mmA B C D E F590 710 295 316 598 90G H J K L140 360 125 550 550SAP Appendix Q PerformanceSpecific Fan ThermalPower (W/l/s) EfficiencyK+1 0.72 92%K+2 0.74 91%K+3 0.81 90%K+4 0.93 88%K+5 1.07 87%84 T: 0844 856 0590


MVHR UnitsELIGIBLE FORSAP APPENDIX QPerformanceFan speeds are fully adjustable within the performance range400100%35080%30025020060%1289615040%5310010782275850 20%443013 200Volume (l/s) 0 10 20 30 40 50 60 70 80Static Pressure (Pa)Volume (m 3 /h) 0 50 100 150 200 250 3000x wattage (both motors)Example system curves -vertical spigotsStatic Pressure (Pa)Volume (l/s)Volume (m 3 /h)450400350300250200150100500100%80%60%40%20%122618 2549380 10 20 30 40 50 600 50 100 150 200 25054897511897x wattage (both motors)Example system curves -horizontal spigotsSound DataOctave band, Hz, dB SWLFlow, l/s Test mode 63 125 250 500 1K 4K 8K SPL dBA@ 3mSupply 47.8 40.2 38 31.1 28.2 23.6 30.9 21.410Extract 47 38.7 36 29.9 25 23.3 30.8 20.6Breakout 43.6 36.2 37.4 30.9 27.4 24.2 31.4 18.6Supply 54 46.6 50.2 44.5 44.4 28.8 31.9 31.220Extract 46.8 40.5 34.6 34.2 34.6 23.7 30.3 22.9Breakout 45.9 39.9 40.6 35.7 33.5 25.3 31.2 21.3Supply 58.1 54.5 57.6 52.2 51.7 38.6 35.8 38.530Extract 47.6 46.2 38.7 41.3 42.8 26.4 30.5 28.4Breakout 45.2 42.4 48.2 40.8 37.7 30 31.1 25.2Supply 65.2 58.4 62.3 58 56.5 44.1 41.4 43.640Extract 53.5 53 44 47.7 48.1 31.5 31.5 33.5Breakout 50.9 47.6 47.4 48.1 42.5 36.3 34.4 29.3Supply 66.4 63.2 66.3 62.5 61.7 50 47.8 48.350Extract 64.2 55.2 48 50.9 52.1 35.9 35 37.2Breakout 55 51 51.3 51.6 46.9 42 38.3 33.2Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemisphericalW: www.vent-axia.com 85


Lo-Carbon Sentinel® Kinetic Cooker HoodConsultants SpecificationOperationThe supply and extract ventilation unit shall beas Sentinel Kinetic as manufactured by <strong>Vent</strong>-<strong>Axia</strong>and shall be sized as indicated on the drawingsand shall be in accordance with the particularspecification.Supply air to the room shall be pre-heated by theextract air via the integrated composite plasticcounterflow heat recovery cell. The Sentinel Kineticshall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of theoptional interconnected sensors. When a signalis received, the fans shall either vary their speedproportionally or on a trickle and boost principle.The unit shall have the facility to commission thesupply and extract fans individually via in-builtminimum and maximum speed adjustment, oralternative wired remote control unit. The fansthemselves shall have independent, infinitelyvariable speed control.Unit specificationThe unit shall be manufactured with an ABS Outercase construction, and incorporate a reversiblecore to allow for left or right hand mounting.The unit shall have a high efficiency compositeplastic counterflow heat exchanger, supply andextract filters, automatic summer bypass, integralminimum and maximum infinitely variable speedcontrols with facia mounted failure indication. Theunit shall have low energy, high efficiency EC/DCfan/motor assemblies with sealed for life bearings.The impellers shall be high efficiency forwardcurved centrifugal type.The unit shall have a heat exchanger cell with athermal efficiency of up to 92% when tested to EN308. This shall be protected by G3 grade syntheticfilters on supply and extract. Complete with acondensate drip tray and drain connection.Standard controlsAll Sentinel Kinetic units shall incorporate thefollowing functions integrally mounted, pre-wiredand factory fitted by the manufacturer: - Integral infinitely variable fan speed control onsupply and extract. Integral min/max ventilation control/set point. Integral BMS interfaces – control and statusindication Heating interlocks 0-10V proportional speed adjustment. Volt free contacts 24V sensor supply Integral on/off or trickle boost function fromremote switch e.g. PIR occupancy detector. The unit shall be controlled by the ‘Sentinel’control devices (enablers and sensors) asdetailed in the schedule or on the drawings. Fully automatic summer bypass Switched Live input with adjustable ‘delay-on’feature Fan failure or component failure indicated viaindividual fault code display. Running time counter Control panel PIN number lock Automatic frost protection effective to -20C The unit shall incorporate (‘H’ models) anintegral humidity sensor with the followingfeatures:Ambient Response; Raises the humiditytrigger point as dwelling temperaturereduces. Rapid Response: Monitors the rate ofchange in humidity and triggers increasedairflow even if the humidity triggerthreshold is not reached.Airflow Direction & Condensate ConnectionToatmosphereFromatmosphereSupplyto dwellingExtractfrom dwelling Proportional Response; Incrementallyincreases the fan speed to reducenoiseand reduce energy consumption. The unit shall be controlled by the ‘Sentinel’control devices (enablers and sensors) asdetailed in the schedule or on the drawings. Tool free filter accessIntegral Cooker Hood SpecificationThe Sentinel Kinetic Cooker Hood shall consistof a telescopic Hood and galvanised steel ductconnection to the MVHR Unit.The Hood construction shall be of grey powdercoated steel with brushed aluminium or whitepainted fascia.The Hood shall trigger the MVHR unit to a predefinedboost speed and open the Summer Bypasswhen opened, and shall have two low-energylamps illuminating the hob top.Filter shall be a flat metal grease filter, removablefor cleaning.The galvanised steel ductwork shall provide acontinuous fire barrier between the Hood andthe MVHR unit. It shall contain an Intumescent firedamper, thermal cut-out and volume balancingdamper. The thermal cut-out shall switch off theMVHR unit at a pre-defined safety temperature.The duct shall have an access panel for cleaningby the end-user.Extractfrom dwellingSupplyto dwellingFromatmosphereToatmosphereThe unit shall be constructed with a removable Coreallowing full maintenance access. The removableCore shall provide access to the following: Supply or extract fan Supply and extract filter Heat exchanger Access to the electrical connectionsAccess shall be provided for wiring terminationand setup/ commissioning. The backlit LCD userinterface therein shall be removable for remotemounting if required.Units shall be as manufactured by <strong>Vent</strong>-<strong>Axia</strong> Ltd.LHRH86 T: 0844 856 0590


MVHR UnitsElectrical ConnectionPlease note: Electrical connection should be carriedout by an appropriately qualified person and inaccordance with current wiring regulations.SETBMS NET J4 3241+ - + - + - + - + - + S - + S - + -S/W1S/W2 S/W3 SW4 S/W5 P1 0-10V P2 0-10V LED L N LS<strong>Vent</strong>-WiseconnectorSwitches 1-5Proportional LEDInputs 1&22m mainscable fittedto unitSwitchedfused spurBrown3ABlackBlueGreen/YellowTrickle to Boost by a light circuit or Ambient Response HumidistatL N LS E220-240V 50HzW: www.vent-axia.com 87


Lo-CarbonSentinel Kinetic®MVHR UnitFeatures & Benefits SAP Appendix Q eligible Ultra quiet Light-weight for easier installation (15kg) Horizontal duct option for space-savinginstallations Fit within a 290mm deep kitchen cupboard Integrated digital controller for simple andaccurate commissioning Plug and play controls; Humidistat, <strong>Vent</strong>-Wise, Wireless remote BMS connectivity LS inputs/(Light Switch) Volt-free inputs Self diagnosis for simplified fault finding Adjustable delay on/delay off timerEasy InstallationThe Sentinel Kinetic models can be mountedvertically in a roof space, and are suitable for wallmounting or within a kitchen cupboard. Whenmounted in an unheated area ducting shouldbe insulated. Ducting can be attached to the unithorizontally, vertically or both. Minimum internaldepth of kitchen cupboard: V&B/BH models290mm.V&B/BH ModelsLeft (L) or right (R) hand installation. The unitis supplied with duct spigots to outside on theright hand side. These can be reversed on site bysimply removing the control panel, rotating the unit180 degrees and re-attaching the control panel.Horizontal and vertical spigots: The combinationof spigot options allows installation in confinedlocations. If vertical and horizontal connection isrequired on the same outlet/inlet, additional spigotscan be suppliedCondensate drain can be taken out through theback, side or bottom of the unit. Using the fittingssupplied, the final condensate connection is madeoutside the unit and can be completed afterinstallation.Integral Humidity SensorThe integral humidity sensor increases speed inproportion to relative humidity levels, saving energyand reducing noise. The sensor also reacts to smallbut rapid increases in humidity, even if the normaltrigger threshold is not reached. This unique featureensures adequate ventilation, even for the smallestwet-room. Night time relative humidity setbackfeature suppresses nuisance tripping as humiditygradually increases with falling temperatureModelsCASModel Stock Ref £ TradeKinetic V 438342 1082.38(non-summer bypass)Kinetic B 438222 1151.84(with summer bypass)Kinetic BH 443319 1221.30(with summer bypass& humidity sensor)AccessoriesCASModel Stock Ref £ TradeWired remote controller 443283 46.31Wireless enable kit 441865 69.46<strong>Vent</strong>-Wise Controller 441780 156.28LED Alarm with 15m cable 448356 25.00For more options, refer to accessories andcontrollers section.SPModel: B & BH Stock Ref £ TradeKinetic Spare Filters 2 pk 441774 18.33F 5 pollen filter 444200 18.33Model: V Stock Ref £ TradeKinetic Spare Filter 2 pk 442356 18.33F5 Pollen 444199 18.33SPDimensions (mm)Weight 15kgA B C D E F G550 550 285 140 125 360 90SAP Appendix Q PerformanceSpecific Fan ThermalPower (W/l/s) EfficiencyK+1 0.72 92%K+2 0.74 91%K+3 0.81 90%K+4 0.93 88%K+5 1.07 87%88 T: 0844 856 0590


MVHR UnitsELIGIBLE FORSAP APPENDIX QPerformanceFan speeds are fully adjustable within the performance range400100%35080%30025020060%1289615040%5310010782275850 20%443013 200Volume (l/s) 0 10 20 30 40 50 60 70 80Static Pressure (Pa)Volume (m 3 /h) 0 50 100 150 200 250 3000x wattage (both motors)Example system curves -vertical spigotsStatic Pressure (Pa)Volume (l/s)Volume (m 3 /h)450400350300250200150100500100%80%60%40%20%122618 2549380 10 20 30 40 50 600 50 100 150 200 25054897511897x wattage (both motors)Example system curves -horizontal spigotsSound DataOctave band, Hz, dB SWLFlow, l/s Test mode 63 125 250 500 1K 4K 8K SPL dBA@ 3mSupply 47.8 40.2 38 31.1 28.2 23.6 30.9 21.410Extract 47 38.7 36 29.9 25 23.3 30.8 20.6Breakout 43.6 36.2 37.4 30.9 27.4 24.2 31.4 18.6Supply 54 46.6 50.2 44.5 44.4 28.8 31.9 31.220Extract 46.8 40.5 34.6 34.2 34.6 23.7 30.3 22.9Breakout 45.9 39.9 40.6 35.7 33.5 25.3 31.2 21.3Supply 58.1 54.5 57.6 52.2 51.7 38.6 35.8 38.530Extract 47.6 46.2 38.7 41.3 42.8 26.4 30.5 28.4Breakout 45.2 42.4 48.2 40.8 37.7 30 31.1 25.2Supply 65.2 58.4 62.3 58 56.5 44.1 41.4 43.640Extract 53.5 53 44 47.7 48.1 31.5 31.5 33.5Breakout 50.9 47.6 47.4 48.1 42.5 36.3 34.4 29.3Supply 66.4 63.2 66.3 62.5 61.7 50 47.8 48.350Extract 64.2 55.2 48 50.9 52.1 35.9 35 37.2Breakout 55 51 51.3 51.6 46.9 42 38.3 33.2Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemisphericalW: www.vent-axia.com 89


Lo-Carbon Sentinel® KineticConsultants SpecificationOperationThe supply and extract ventilation unit shall beas Sentinel Kinetic as manufactured by <strong>Vent</strong>-<strong>Axia</strong>and shall be sized as indicated on the drawingsand shall be in accordance with the particularspecification.Supply air to the room shall be pre-heated by theextract air via the integrated composite plasticcounterflow heat recovery cell. The Sentinel Kineticshall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of theoptional interconnected sensors. When a signalis received, the fans shall either vary their speedproportionally or on a trickle and boost principle.The unit shall have the facility to commission thesupply and extract fans individually via in-builtminimum and maximum speed adjustment, oralternative wired remote control unit. The fansthemselves shall have independent, infinitelyvariable speed control.Unit specificationThe unit shall be manufactured with an ABS Outercase construction, and incorporate a reversiblecore to allow for left or right hand mounting.Standard controlsAll Sentinel Kinetic units shall incorporate thefollowing functions integrally mounted, pre-wiredand factory fitted by the manufacturer: Integral infinitely variable fan speed control onsupply and extract. Integral min/max ventilation control/set point. Integral BMS interfaces – control and statusindication Heating interlocks 0-10V proportional speed adjustment. Volt free contacts 24V sensor supply Integral on/off or trickle boost function fromremote switch e.g. PIR occupancy detector. The unit shall be controlled by the ‘Sentinel’control devices (enablers and sensors) asdetailed in the schedule or on the drawings. Fully automatic summer bypass Switched Live input with adjustable ‘delay-on’feature Fan failure or component failure indicated viaindividual fault code display. Running time counter Control panel PIN number lock Automatic frost protection effective to -20C The unit shall incorporate (‘H’ models) anintegral humidity sensor with the followingfeatures: Ambient Response; Raises the humiditytrigger point as dwelling temperaturereduces. Rapid Response: Monitors the rate ofchange in humidity and triggers increasedairflow even if the humidity triggerthreshold is not reached.Proportional Response; Incrementallyincreases the fan speed to reduce noiseand reduce energy consumption. The unit shall be controlled by the ‘Sentinel’control devices (enablers and sensors) asdetailed in the schedule or on the drawings. Tool free filter accessThe unit shall have a high efficiency compositeplastic counterflow heat exchanger, supply andextract filters, automatic summer bypass, (B/BH)integral minimum and maximum infinitely variablespeed controls with facia mounted failure indication.The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for lifebearings. The impellers shall be high efficiencyforward curved centrifugal type.The unit shall have a heat exchanger cell with athermal efficiency of up to 92% when tested to EN308. This shall be protected by G3 grade syntheticfilters on supply and extract. Complete with acondensate drip tray and drain connection.Airflow Direction & Condensate Connection (RH Supplied)ToatmosphereFromatmosphereSupplyto dwellingExtractfrom dwellingExtractfrom dwellingSupplyto dwellingFromatmosphereToatmosphereThe unit shall be constructed with a removable Coreallowing full maintenance access. The removableCore shall provide access to the following: Supply or extract fan Supply and extract filter Heat exchanger Access to the electrical connectionsAccess shall be provided for wiring terminationand setup/ commissioning. The backlit LCD userinterface therein shall be removable for remotemounting if required.Units shall be as manufactured by <strong>Vent</strong>-<strong>Axia</strong> Ltd.LHRH (supplied)90 T: 0844 856 0590


MVHR UnitsElectrical ConnectionPlease note: Electrical connection should be carriedout by an appropriately qualified person and inaccordance with current wiring regulations.SETBMS NET J4 3241+ - + - + - + - + - + S - + S - + -S/W1S/W2 S/W3 SW4 S/W5 P1 0-10V P2 0-10V LED L N LS<strong>Vent</strong>-WiseconnectorSwitches 1-5Proportional LEDInputs 1&22m mainscable fittedto unitSwitchedfused spurBrown3ABlackBlueGreen/YellowL N LS E220-240V 50HzTrickle to Boost by Trickle/Boost switchW: www.vent-axia.com 91


Lo-CarbonSentinel Kinetic® HorizontalMVHR UnitFeatures & Benefits Manufactured in the UK Building Regulations ADF compliant SAP Appendix Q Eligible Energy Savings Trust best practice compliant Up to 85% heat recovery whilst controllingcondensation Programmable Summer bypass Digital controller for simple and accuratecommissioning External condensate connection Plug and play controls; Humidistat,<strong>Vent</strong>-Wise, Wireless remote LS inputs/(Light Switch) Volt-free inputs Self diagnosis for simplified fault finding Adjustable delay on/delay off timerThe Sentinel Kinetic Horizontal RangeA wholehouse heat recovery system with up to 85%heat exchange efficiency. An easily accessible heatrecovery cube protected by two removable EU3filters. Two Lo-Carbon Energy Saving EC DC fansensure long life (typically over double the life ofAC motors) and lowest possible energy use. Fullyinsulated construction with built in condensation drain.Specifically designed for new build constructions witha high level of insulation.Lo-Carbon Sentinel Kinetic meets the latest requirementsof the Building Regulations ADF for wholehouse systemventilation: System 4. Continuous mechanical supplyand extract with heat recovery. The Lo-Carbon SentinelKinetic models have 3 fully adjustable speeds and apurge setting - maximum. Supplied with the unit is adigital controller that can be used to pre-set the speedsto any required air-flow within the performance range.Integral Humidity SensorThe integral humidity sensor (‘H’ models) increasesspeed in proportion to relative humidity levels, savingenergy and reducing noise. The sensor also reacts tosmall but rapid increases in humidity, even if the normaltrigger threshold is not reached. This unique featureensures adequate ventilation, even for the smallestwet-room. Night time relative humidity setback featuresuppresses nuisance tripping as humidity graduallyincreases with falling temperature. Acoustically lined -low noise levels from only 20dB(A) @3m.ModelsCASModel Stock Ref £TradeKinetic 200Z 448733 1151.84Kinetic 200ZH 449540 1221.30(humidity sensor)Kinetic 300Z 447801 1365.00Kinetic 300ZH 449536 1434.46(humidity sensor)Optional ControlsCASModel Stock Ref £TradeWireless enable kit 441865 69.46(includes one switch)Wireless boost switch 437827 42.96(max 3 switches)<strong>Vent</strong>-Wise Controller 441780 156.28(also requires sensors, see Accessories & Controllerssection)Multiple control options:Five Volt-free pairs of switch terminals for sensor inputsallow boosting from a full range of <strong>Vent</strong>-<strong>Axia</strong> controllers– humidistats, PIR, timers.Two terminals with 0-24V outputs allow 0V to 10Vproportional control by sophisticated controllers suchas CO 2sensors and proportional humidistats.The optional <strong>Vent</strong>-Wise controller senses temperaturerise in a bath/shower hot water supply and/or currentin a cooker/hob electrical circuit to activate boost,ensuring additional ventilation when needed. Switchlivefor boosting via light switches (220-240 V AC) ormanual Normal/Boost switches. This connection hasthe advantage of Delay-On and Delay-Off facility.Delay-On enables you to prevent the Boost airflowbetween 0 and 10 minutes, after a light switch hasbeen activated. Delay-Off allows the Boost airflowto continue after a light switch is turned off to ensureeffective clearance of humidity. This timer is adjustablebetween 0 and 25 minutes.Summer BypassAn internal damper is activated when the outsidetemperature is less than the room temperature. Thedamper opens allowing cooler fresh air to bypassthe Heat Recovery Cell and reduce the internaltemperature towards the pre-set ‘Comfort Temperature’.When the inside air temperature reaches the pre set‘Comfort Temperature’ the bypass damper closes. Antifrostprotection: In cold climates there is a possibilityof frost building up on the intake side of the heatexchanger. In order to prevent damage, the Kineticreduces supply flow while maintaining extract flow attemperatures below 0˚C.Specific Fan Power200 Hz 300 HzW/l/s %* W/l/s %*K+1 0.62 80 0.59 81K+2 0.71 79 0.51 80K+3 0.83 78 0.57 79K+4 0.66 78K+5 0.76 77K+6 0.88 76* EstimatedDimensions (mm)SideFrontECDFGABHBackModel A B C D E Dia Ø200Z 895 849 200 570 155 125300Z 985 940 301 720 184 150F G H I J K200Z 144 122 76 167 131 122300Z 179 187 102 279 174 108IJK92 T: 0844 856 0590


MVHR UnitsPerformanceFan speeds are fully adjustable within the performance range300200Z500300Z450250400Static Pressure (Pa)200150100100%Static Pressure (Pa)35030025020015060%100%5010040%5020%0Volume (l/s)0 5 10 15 20 25 30 35 400Volume (l/s) 0 10 20 30 40 50 60 70 80 90 100Volume (m3/hr)0 25 50 75 100 125 150Volume (m3/hr)0 50 100 150 200 250 300 350Sound Data - 300Z ModelFlow, l/s Flow % Test mode 63 125 250 500 1k 2k 4k 8k dB(A) at 3mSupply 42.5 42.8 38.3 32.9 28 24.6 25.5 30.3 26.326 10% Extract 46.9 45 40.3 34.4 27.4 23 24.3 30.1 22.5Breakout 48.7 52.1 47.7 40.5 32.9 27.3 25.1 31.6 24.4Supply 45.6 47 41.7 35.7 31.7 26.7 24.8 30 29.944 20% Extract 46.9 48.6 47 38.2 29.5 25.3 23.8 29.9 25.3Breakout 50.2 56.4 53.9 46.3 37.5 32.5 25.2 31.4 28.8Supply 44.4 46 52.9 39.4 35.1 31.9 25.5 30.5 33.955 30% Extract 47 48 55.5 42.5 32.2 29.9 25.7 30.6 30.6Breakout 52.2 59.6 62 51.4 41.9 37.4 28.1 31.4 34.7Supply 43.1 44.4 54.3 43.5 39.2 35.7 27.7 29.9 35.066 40% Extract 48.9 49 58.4 45.9 35.7 33.4 25.3 29.9 33.4Breakout 54.6 58.3 66.1 52.6 39.3 36.5 31.1 35.3 37.7Supply 44.7 49.8 58 50.4 45 41.9 30.6 30.3 39.185 60% Extract 51 53.6 61.2 50.1 41.6 40.1 30.7 31.1 36.7Breakout 57.5 62.6 68.7 57.5 45.9 41 36.3 34 40.7Supply 46 52.2 57.1 56.5 47.2 44.2 32.3 30.5 40.596 80% Extract 55.5 55 63.1 53.4 44.3 41 33.5 31.4 38.8Breakout 62.2 65.7 68.8 63 50.8 43.8 38.8 35.4 42.9Supply 46.6 52.3 57 55.4 47.1 43.7 32.1 30.3 40.198 100% Extract 53.7 55.2 63.3 53.3 44.1 41.2 33.2 31.5 38.9Breakout 62.2 73.8 77.4 74.1 67.4 61 53.6 45.4 53.9Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemisphericalW: www.vent-axia.com 93


Lo-Carbon Sentinel® Kinetic HorizontalConsultants SpecificationOperationThe supply and extract ventilation unit shall be asSentinel Kinetic Z as manufactured by <strong>Vent</strong>-<strong>Axia</strong> andshall be sized as indicated on the drawings and shallbe in accordance with the particular specification;200Z – 200mm deep, 300Z – 300mm deep.Supply air to the room shall be pre-heated by theextract air via the integrated aluminium counterflowheat recovery cell. The Sentinel Kinetic Z shallautomatically vary the ventilation rate via EC/DCmotors, as it receives signals from one of the optionalinterconnected sensors. When a signal is received, thefans shall either vary their speed proportionally or on atrickle and boost principle.The unit shall have the facility to commission thesupply and extract fans individually via the wiredremote control unit. The fans themselves shall haveindependent, infinitely variable speed control.Unit specificationThe unit shall be manufactured with a galvanizedsteel outer case construction and shall be suitable forhorizontal ceiling void/slab mounting.The unit shall have a high efficiency aluminiumcounterflow heat exchanger, supply and extract filters,automatic summer bypass, integral minimum andmaximum infinitely variable speed controls with failureindication via the wired remote controller.The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for life bearings.The impellers shall be high efficiency backward curvedcentrifugal type.The unit shall have a heat exchanger cell with a thermalefficiency of up to 85% when tested to EN 308. Thisshall be protected by G3 grade synthetic filters onsupply and extract. Complete with a condensate driptray and drain connection.The unit shall be constructed with a removable accesspanel allowing full maintenance access from below.The removable panel shall provide access to thefollowing: Supply or extract fan Supply and extract filter Heat exchanger Access to the electrical connectionsAccess shall be provided for wiring termination andsetup/ commissioning. Units shall be as manufacturedby <strong>Vent</strong>-<strong>Axia</strong> Ltd.Standard controlsAll Sentinel Kinetic Z units shall incorporate thefollowing functions integrally mounted, pre-wired andfactory fitted by the manufacturer: - Integral infinitely variable fan speed control onsupply and extract. Integral min/max ventilation control/set point. Heating interlocks 0-10V proportional speed adjustment. Volt free contacts 24V sensor supply Integral on/off or trickle boost function fromremote switch, e.g. PIR occupancy detector. The unit shall be controlled by the ‘Sentinel’control devices (enablers and sensors) asdetailed in the schedule or on the drawings. Fully automatic summer bypass Switched Live input with adjustable ‘delay-on’feature Fan failure or component failure indicated viaindividual fault code display. Running time counter Control panel PIN number lock Automatic frost protection effective to -5˚C The unit shall incorporate (‘H’ models) anintegral humidity sensor with the followingfeatures: Ambient Response; Raises the humiditytrigger point as dwelling temperaturereduces. Rapid Response: Monitors the rate ofchange in humidity and triggers increasedairflow even if the humidity trigger thresholdis not reached. Proportional Response; Incrementallyincreases the fan speed to reduce noise andreduce energy consumption.The unit shall be controlled by the ‘Sentinel’ controldevices (enablers and sensors) as detailed in theschedule or on the drawings.Airflow Direction & Condensate Connection (RH Supplied)Extract fromDwellingSupply toDwellingYellowRedGreenBrownFromAtmosphereToAtmosphereNote: Postion of powersupply in relation to ducting94 T: 0844 856 0590


MVHR UnitsElectrical ConnectionPlease note: Electrical connection should be carried out by an appropriately qualified person and in accordance with current wiring regulations.Wired Remote Controller4NET J4 321+ - + - + - + - + - + S - + S - + -S/W1 S/W2 S/W3 SW4 S/W5 P1 0-10V P2 0-10V LED L N LS<strong>Vent</strong>-WiseconnectorSwitches 1-5ProportionalInputs 1&2LED2m mainscable fittedto unitSwitchedfused spurBrown3ABlackBlueGreen/YellowL N LS E220-240V 50HzTrickle to Boost by two lighting circuits or Trickle/Boost switchW: www.vent-axia.com 95


Lo-CarbonKinetic® Plus EMVHR UnitFeatures & Benefits Light weight for easy installation Easy access filters External condensate connection Compatible with a range of controls: PIR,Humidistat Horizontal spigot option Up to 94% heat recovery Quiet operation Manufactured in the UK Switched live inputs (Light switch control)A wholehouse heat recovery system with 94%energy efficiency. An easily accessible heatrecovery cube protected by two removable EU3filters. Two Lo-Carbon Energy Saving EC DC fansensure long life (typically over double the life ofAC motors) and lowest possible energy use. Fullyinsulated construction with built in condensationdrain.Lo-Carbon Kinetic Plus E meets the latestrequirements of the Building Regulations ApprovedDocument F for wholehouse system ventilation.The Lo-Carbon Kinetic Plus E model has 2 adjustablespeeds, normal and boost. On the front of the unit isthe controller that can be used to pre-set the speedsto any required performance, up to 400m 3 /hr(111l/s) 150pa. Offering ‘Close Control’ to preventover ventilating. Acoustically lined - low noise levelsfrom only 20dB(A) @3m.Left or right hand installationUnits are supplied as RH version with duct spigotsto outside on the right hand side. These can bereversed onsite by simply removing the controlpanel, rotating the unit 180 degrees and reattachingthe control panel.Horizontal and vertical spigotsThe combination of spigot options allows installationin confined locations. If vertical and horizontalconnection is required on the same outlet/inlet,additional spigots can be supplied.Frost ProtectionThe Kinetic E range benefits from an automaticfrost protection system which manages the air-flowsto prevent the heat recovery cell freezing in verycold weather, while at the same time maintainingventilation.Control optionsThere are two LS (Switched Live) inputs allowing theunit to be connected to a number of sensors andcontrollers such as <strong>Vent</strong>-Wise, Timespan, AmbientResponse Humidistat.One of the LS connectionsalso benefits from a ‘delay on’ feature whichprevents the unit boosting unnecessarily.ModelCASModel Stock Ref £TradeKinetic Plus E 449059 1360.21AccessoriesSPModel Stock Ref £TradeKinetic Spare 443351 29.14Filters 2 packOptional F5 444201 27.76Pollen FilterSAP Appendix Q Test ResultsExhaust TerminalSpecific FanPower ThermalConfiguration (W/l/s) EfficiencyKitchen + 1additional wet room0.41 94Kitchen + 2additional wet rooms0.40 94Kitchen + 3additional wet rooms0.43 94Kitchen + 4additional wet room0.45 94Kitchen + 5additional wet rooms0.52 93Kitchen + 6additional wet rooms0.61 93Kitchen + 7additional wet rooms0.73 93Dimensions (mm)A B C D EØ F G785 632 722 526 150 520 275AFCBDGEØ96 T: 0844 856 0590


MVHR UnitsELIGIBLE FORSAP APPENDIX QPerformanceFan speeds are fully adjustable within the performance range600500400Static Pressure (Pa)300200100%10060%80%0020%40%20 40 60 80 100 120 140 160l/s0 50 100 150 200 250 300 350 400 450 500 550Volumem 3 /hAirflow Direction & Condensate Connection (RH Supplied)Extract from dwellingSupply to dwellingFromatmosphereTo atmosphereFilterAccessPanelsControl UnitSpigotBlankingCapsNormalCondensateConnectionAlternativeCondensateConnectionsW: www.vent-axia.com 97


Lo-CarbonKinetic® EMVHR UnitFeatures & Benefits Compact and quiet. Light weight for easy installation. Easy access filters. External condensate connection. Compatible with a range of controls: PIR,Humidistat Horizontal spigot option. Energy saving ECDC motors Quiet operation. Manufactured in the UK. Switched live inputs (Light switch control)A wholehouse heat recovery system with 91%energy efficiency. An easily accessible heatrecovery cube protected by two removable EU3filters. Two Lo-Carbon Energy Saving EC DC fansensure long life (typically over double the life ofAC motors) and lowest possible energy use. Fullyinsulated construction with built in condensationdrain.Lo-Carbon Kinetic E meets the latest requirements ofthe Building Regulations Approved Document F forwholehouse system ventilation.The Lo-Carbon Kinetic E model has 2 adjustablespeeds, normal and boost. On the front of the unit isthe controller that can be used to pre-set the speedsto any required performance, up to 135m 3 /hr(38l/s) 100pa. Offering ‘Close Control’ to preventover ventilating. Acoustically lined - low noise levelsfrom only 20dB(A) @3m.Left or right hand installationUnits are supplied as RH version with duct spigotsto outside on the right hand side. These can bereversed onsite by simply removing the controlpanel, rotating the unit 180 degrees and reattachingthe control panel.connection is required on the same outlet/inlet,additional spigots can be supplied.Frost ProtectionThe Kinetic E range benefits from an automaticfrost protection system which manages the air-flowsto prevent the heat recovery cell freezing in verycold weather, while at the same time maintainingventilation.Control optionsThere are two LS (Switched Live) inputs allowing theunit to be connected to a number of sensors andcontrollers such as <strong>Vent</strong>-Wise, Timespan, AmbientResponse Humidistat.One of the LS connectionsalso benefits from a ‘delay on’ feature whichprevents the unit boosting unnecessarily.ModelCASModel Stock Ref £ TradeKinetic E 443303 937.13AccessoriesSPModel Stock Ref £ TradeKinetic Spare 442356 18.33Filters 2 packOptional F5 444199 18.33Pollen FilterSAP Appendix Q Test ResultsExhaust TerminalSpecificFanPower ThermalConfiguration (W/l/s) EfficiencyKitchen + 1 additional wet room 0.51 91%Kitchen + 2 additional wet rooms 0.58 90%Kitchen + 3 additional wet rooms 0.71 89%Dimensions (mm)Airflow Direction & Condensate Connection (RH Supplied)ToatmosphereSupplyto dwellingFromatmosphereExtractfrom dwellingA B C D E F G550 550 285 140 125 360 90Extractfrom dwellingSupplyto dwellingFromatmosphereToatmosphereHorizontal and vertical spigotsThe combination of spigot options allows installationin confined locations. If vertical and horizontalLHRH (supplied)98 T: 0844 856 0590


MVHR UnitsELIGIBLE FORSAP APPENDIX QPerformanceFan speeds are fully adjustable within the performance range250200Prrssure Pa1501001411121314K+1K+2K+3Max50121311Sound DataFlow, l/s15212731MAX00 10 20 30 40 50 l/s0 20 40 60 80 100 120 140 160 180 m3 /hVolumeOctave band, Hz, dB SWLSPLTest mode 63 125 250 500 1k 2k 4k 8k dB(A) at 3mSupply 43.5 44.7 40.4 38.9 35.7 27.1 24.8 29.5 28.3Extract 45.0 42.1 34.5 32.4 32.7 24.1 24.5 30.7 22.2Breakout 53.6 52.6 47.7 47.2 43.1 35.3 24.1 30.0 28.3Supply 43.4 49.2 45.9 42.8 42.1 35.2 27.7 30.6 32.2Extract 45.4 42.6 37.1 33.8 35.5 28.2 23.8 30.3 23.5Breakout 48.9 42.9 49.4 47.9 44.2 39.8 26.4 30.6 29.2Supply 47.0 52.1 49.3 46.3 46.1 39.6 31.3 31.2 35.4Extract 45.7 43.9 37.6 37.8 40.3 31.5 25.6 31.0 26.3Breakout 48.0 45.6 48.0 48.2 47.4 39.1 28.8 29.8 30.3Supply 46.8 57.7 53.8 51.2 50.0 44.2 37.5 33.2 40.1Extract 47.1 45.2 40.6 40.8 44.2 35.1 28.7 31.3 29.3Breakout 50.2 46.9 48.2 50.0 47.7 41.7 31.4 30.3 31.3Supply 48.0 58.9 57.8 54.4 53.2 49.0 42.1 36.0 42.6Extract 46.1 45.4 41.2 42.1 43.4 35.8 29.6 31.0 29.1Breakout 51.9 48.0 51.1 52.0 47.0 44.5 34.1 31.7 32.5Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemisphericalW: www.vent-axia.com 99


MVHR UnitsIntegra®Ducted MVHR UnitFeatures & Benefits Powered heat recovery unit for smallerresidential or commercial applications upto 180m 2 Up to 70% heat recovery Low power consumption Effective condensation controlThe Integra heat recovery unit has been speciallydesigned to provide ventilation for flats or internalrooms in residential, commercial, educationalor leisure applications. Balanced ventilation isachieved by using nominal 100mm diameterinsulated flexible ducting.Using a high performance, polymeric heatexchange cube, together with two powerfulfans, the <strong>Vent</strong>-<strong>Axia</strong> Integra boasts a temperatureefficiency of up to 70%.The compact cube interleaves outgoing moist airwith incoming fresh air, allowing the heat from oneto warm the other without the two air streams mixing.Energy is saved on room heating, with no powerbeing used by the cube itself.Performance of Integra: Up to 49l/s FID. Ideal forinstallation in the ceilings voids or cupboards.The 150VA Transformer enables the selection oftrickle settings to match dwelling volume.ModelsIntegraCASStock Ref£ Trade456864 551.76Controller 150VAGENStock Ref£ Trade563538 84.87Dimensions (mm)Weight: 6.5kg21065Supply todwelling400135Extract from dwelling8523085400504 - 98 ØSpigotsFrom atmospherePerformanceFan Static Pr essur e (Pa)30025020015010050160v120v 140v100v80v240v00 10 20 30 40 50Volume l/sIntegra to be used with a 150VATransformer for maximumcontrollabilityMotorSpeed 1 2 3 4 5 6Volume l/s(FID)15.3 21.3 27.3 32.4 37.1 48.7Power ConsumptionSpeed 1 80V 32WSpeed 2 100V 47WSpeed 3 120V 64WSpeed 4 140V 81WSpeed 5 160V 99WSpeed 6 240V 182WTo atmosphere100 T: 0844 856 0590


MVHR UnitsIntegra® PlusDucted MVHR UnitFeatures & Benefits Powered heat recovery unit for largerresidential or commercial applications Up to 70% heat recovery Low power consumption Effective condensation control 3 speed controlEasy InstallationThe <strong>Vent</strong>-<strong>Axia</strong> Integra Plus is designed for mountingin ceiling voids, lofts, above a suspended ceilingor vertical wall mounting. Four 150mm spigots areprovided for simple connection to insulated flexibleor rigid ventilation ducting. The unit comes completewith a 22mm condensate outlet.ModelCASStock Ref£ Trade437666 852.83PerformancePressure (Pa)1 2600500940083007620051004300 20 40 60 80 100 120 140 160Volume l/sUnits supplied complete with transformerMotor Speed 1 2 3 4 5 6 7 8 9Volume l/s (FID) 22 30 38 48 55 78 102 128 154Transformer Voltage V 50 62 74 86 98 130 160 190 230Controllers & SensorsDimensions (mm)Weight : 15.5kg fan box, 5kg controller603580305 1001653551252151251253504 - 150 ØSpigotsTrickle BoostSwitchSupply todwellingAmbient ResponseHumidistatVisionexPIRTIM27 DayTimeSwitch3 PositionSwitch455213 563550A 459623A 370346 563515 5108454Extract from dwellingFromatmosphereTo atmospherePower Consumption andnoise leveldB(A) @ 3mSpeed 1 30W 50V 19.2Speed 2 45W 62V 19.5Speed 3 66W 74V 20.9Speed 4 85W 86V 21.9Speed 5 115W 98V 24.5Speed 6 188W 130V 30.8Speed 7 262W 160V 34.3Speed 8 330W 190V 36.9W: www.vent-axia.com 101


MVHR UnitsHR100R/RSDucted MVHR UnitFeatures & Benefits Controls condensation and odours - savesenergy Eliminates mould growth Up to 70% Heat Recovery Extremely quiet operation Two speed settingsThe HR100R and HR100RS are ideal for singlebedroom/bathroom applications such as hotelrooms, nursing homes and residential care homes.The HR100R features top access and is ideal forloft installations.ModelsHR100RCASTop access - ideal in loft installations.Stock Ref£ Trade370377 167.93HR100RSCASBottom access - ideal for suspended ceilings.Stock Ref£ Trade435004 209.31Performance120100Dimensions (mm)16070240FanEnd605012060305504 - 98 ØSpigotsThe HR100RS features bottom access and isideal for installation on the ceiling slab above asuspended ceiling.The HR100R/RS is a self-contained heat recoveryunit for mounting in lofts and suspended ceilings.The unit is supplied without controls to allow for theunit to be tailored to suit the individual requirements.Pressure Pa80604020010 2 4 6 8 10 12 14 16 18Volume l/s2HR100RS versionCompatible with standard 100mm ducting forconnection to internal grilles and external cowl.1 Trickle 2BoostThe unit comes fitted with a single 2-speed motor,and provides continuous low volume ventilationwith a boost option. A variety of control devices areavailable for manual or automatic speed control.An integral heat exchanger transfers heat from theoutgoing stale air to the fresh air supply, raisingthe supply air temperature whilst at the same timereducing its relative humidity.Up to 18l/s FID capacity. The unit provides superiorcontrol of condensation and odours, ideal forbathrooms or small internal rooms.PerformanceWeight Extract Perf. l/s Watts dB(A) @ 3m*Model Kg Boost Trickle Boost Trickle Boost TrickleHR100R 5.6 18.3 13.6 29 19 30 20HR100RS 5.6 18.3 13.6 29 19 30 20Mains electrical supply: 230V/50Hz102 T: 0844 856 0590


MVHR UnitsHR200VDucted MVHR UnitFeatures & Benefits Powered heat recovery module forsmaller commercial applications. Up to 70% heat recovery. With 150mm duct connection. Extremely quiet on low speeds. Low power consumption. Washable heat exchanger. Pre-wired to a flexible cable.A ducted heat recovery unit for internal rooms.Self-contained and includes two mixed flow speedcontrollable fans. Using a high performance,polymeric heat exchange cube together with twopower fans, the HR200V can boast a temperatureefficiency of up to 70%. Low speed for trickleventilation mode.Specially designed to provide ventilation for smallinternal rooms in commercial, educational andleisure applications. <strong>Vent</strong>ilation is achieved by usingnominal 150mm diameter ducting. The unit includestwo mixed flow speed controllable fans plus a highefficiency polymeric heat exchanger.ModelsHR200VCASStock Ref£ Trade14120010 456.48Transformer 150VAGENStock Ref£ Trade563538 84.87PerformanceStatic Pressure (Pa)1401201008060402000 20 40 60 80 100 120Volume (l/s)240V Supply160V Supply140V Supply240V Extract160V Extract140V ExtractMotor Speed 1 2 3Voltage 140 160 240Watts 51.5 60 110Volume l/s (FID) Supply 48.3 55.8 70.3Extract 241 286 371HR200V to be used with a 150VA Transformer formaximum controllability.Dimensions (mm)Weight : 15.5kg fan box, 5kg controller275Extr act fromdwelling3734 - 148 ØSpigotsSupply todwellingCL951833095435Fan End30To atmosphereFrom atmosphereW: www.vent-axia.com 103


MVHR UnitsHR250MVHR UnitFeatures & Benefits Wholehouse ventilation unit with heatrecovery Up to 70% heat recovery whilst controllingcondensation Easy installation using 100mm diameterduct spigots Pre-moulded plug and 2 metrelong flying leadCupboard/loft-mounted intake/extract wholehouseventilation unit with built-in heat recovery facility. Ithas twin centrifugal motor/impellers which providebalanced supply and extract ventilation with up to70% heat recovery. In conjunction with the 150VATransformer the unit has the facility for matching theperformance of the unit to the size of dwelling.ModelHR250CASStock Ref£ Trade14125010 725.16Contoller 150VAGENStock Ref£ Trade563538 84.87Power ConsumptionSpeed 1 80V 20WSpeed 2 100V 36WSpeed 3 120V 51WSpeed 4 140V 60WSpeed 5 160V 80WSpeed 6 240V 185WDimenisons (mm)Weight: 11.5kg6 - 100mm ØSpigots13856057120Supply to dwelling20012060290120490PerformancePerformance of HR250: Up to 61l/s FID capacity(balanced airflow). Unit extracts the moist andpolluted air from kitchens, utility rooms, bathroomsand toilets and replenishes other areas of thedwelling with fresh tempered air.The 150VA Transformer enables the selection oftrickle settings to match dwelling volume.Motor Speed 1 2 3 4 5 6Volume l/s (FID) 15.8 25 31.1 37.5 43.1 61.1HR250 to be used with a 150VA Transformer formaximum controllability.Extract from dwellingFrom atmosphereTo atmosphere300250200Static Pressur e (Pa)150100240v50160v140v120v100v80v00 10 20 30 40 50 60 70Volume (l/s)104 T: 0844 856 0590


MVHR UnitsHR400MVHR UnitPr essure (Pa)Features & Benefits Controls condensation and odours Up to 70% heat recovery Balanced supply and extract air flows Eliminates mould growth Reduced redecorating cost Added security benefits Benefits to asthma and hay fever sufferers Pre-moulded plug & 2 metre long flyingleadThe HR400 is a wholehouse ventilation systemcomprising a fan assisted heat recovery unit. TheHR400 is usually installed as a single unit, butmultiple systems can be used for zoning or increasedcapacity. The unit offers an optional pollen filter forthe fresh air supply, this option benefits asthma andhay fever sufferers.Performance35030025020015010050100V80V00 10 20 30 40 50 60 70 80 90Volume (l/s)140V120V160V240VSelectable performance levels: Up to 86l/s, basedon typical ducted systems. The HR400 can be usedinstalled in many types of building - houses, flats,bungalow’s, offices and nursing homes, etc.The VCON77 Transformer offers maximumcontrollability with six voltage selections for tricklesettings to match dwelling volume.ModelsHR400CASStock Ref£ Trade370552 770.74Contoller VCON77CASStock Ref£ Trade370357 65.00HR400 to be used with a VCON77Transformer for maximumcontrollabilityMotor Speed 1 2 3 4 5 6Volumel/s (FID)38.9 50.0 61.1 68.1 75 86.1Sound LevelsLeveldB(A) @ 3mMin 26Max 56Dimenisons (mm)Weight: 19kg4 - 100mm ØSpigots1 - 100/150mmØ Spigots40300595Supply to dw ellingExtr act from d wellingFrom atmosphereTo atmosphere1852251852805050510W: www.vent-axia.com 105


MVHR UnitsHR500Single Room HeatRecovery UnitFeatures & Benefits Efficient 550m 3 /h heat recovery ventilationunit or high performance 900m 3 /h extractfan Lightweight, compact and easy to install Integral shutters on X type model Easy to clean 70% heat recovery Controller with sensor mode, allows arange of sensors to be used in conjunctionwith the HR500 and HR500X units Rated to IPX5 suitableHeat Recovery <strong>Vent</strong>ilationHR500 heat recovery ventilation units for throughwall installation, which exhaust stale air whilstintroducing warmed fresh air from the outside.PerformanceIdeal for computer rooms, classrooms, offices andthe health and leisure industries. The <strong>Vent</strong>-<strong>Axia</strong>HR500 unit is the perfect solution to commercialareas that require a high performance balancedintake/extract scheme. As a heat recoveryventilation unit it moves a useful 153l/s of air.The compact heat recovery cube interleavesoutgoing warm air with incoming fresh air andallows the heat from one to warm the other withoutthe two streams mixing. Energy is saved on roomheating with no power being used by the cube itself.The HR500 and HR500X consist of a toughtelescopic wall sleeve into which the main body ofthe unit is housed. Walls of up to 670mm thick can beeasily accommodated. Behind the neat deflectingfascia grilles are the filters, the heat exchange cubeand fan units. All wall sleeve components, the heatexchange cube and the fascia grilles are made oftough polymeric materials.Airflow performance (l/s)SoundHeat recovery Extract mode Watts dB(A) @ 3mModel mode (max) (max) (max)HR500 153l/s 250l/s 200 53HR500X 153l/s 250l/s 220 53ElectricalMaximum ambient temperature +40˚C.Supply Voltage 220-240V/1/50Hz.ModelsHR500 CommercialDOMWall-mounted intake/extract ventilation unit withbuilt-in heat recovery facility. For commercial andleisure areas. Lightweight, compact and easy toinstall.Stock Ref£ Trade14101010 833.05HR500XDOMAs HR500 with shutters.Stock Ref£ Trade14101070 1035.04HR500 ControllerDOMSurface mounting. On/Off remote sensor mode.Heat exchange, single fan extract or twin fan extractmodes. Infinitely variable speed. Minimum speedsetting. Suitable for controlling up to 2x HR500Stock Ref£ TradeW14301010 126.97HR500 & HR500X106 T: 0844 856 0590


002503 100MVHR UnitsHR500DDucted MVHR UnitFeatures & Benefits Self-contained unit with integral fans Up to 70% heat recovery Compatible with 315, 250 and 200mm Ø,ducting and accessories External wall mounting Speed Controller W14301010The HR500D is a self-contained unit with integralextract and supply fans to provide balancedventilation and heat recovery via supply diffusersand extraction grilles. The unit is fully speedcontrollable.The compact heat recovery cube interleavesoutgoing warm air with incoming fresh air andallows the heat from one to warm the other withoutthe two streams mixing.PerformanceHeat Exchanger EfficiencyEnergy is saved on room heating with no powerbeing used by the cube itself.Performance of HR500D: Supply and extract up to174l/s FID capacity on heat recovery mode. Idealfor offices, computer rooms, pubs and clubs, etc.ModelSurface mounting. On/Off remote sensor mode.Heat exchange, single fan extract or twin fan extractmodes. Infinitely variable speed. Minimum speedsetting. Suitable for controlling up to 2x HR500.HR500DDOMStock Ref£ Trade370450 761.97Speed ControllerDOMStock Ref£ TradeW14301010 126.97Spigot Sets200mm Spigot setGENStock Ref£ Trade+ 434806 45.24+ 434805 45.24250mm Spigot setGENStock Ref£ Trade+ 434806 45.24+ 434805 45.24315mm SpigotGENStock Ref£ Trade+ 434806 45.24Dimensions (mm)Hole opening: 610 x 381mmFrom atmosphere480 - 750Extract fromdwellingPlan120 22070 15530 90To atmosphereAdditionalSpigots434806 (Setof 2)Supply todwellingAdditionalSpigots434805(Set of 2)2 ØØ3 Ø5 Ø340600Airflow performance l/s Watts dB(A) @ 3m(max) (max) (max) Weight kg174 l/s 210 53 19End ElevationW: www.vent-axia.com 107


002503 100MVHR UnitsHR500EP/IPPassive MVHR UnitFeatures & Benefits Passive - no fans Lightweight - easy installation Compatible with 315, 250 and 200mm Øducting and accessories Saves Heat - 70% heat recovery Internal wall mounting HR500IP External wall mounting HR500EPPerformancePressure Drop over Heat Exchange UnitThe unit is a semi-remote heat exchange unitwith 70% heat recovery, designed for mountingin internal walls (HR500IP) and external walls(HR500EP) for installations using ducted extractionand fresh air supply. The HR500 units provides airmovement via two independent in-line duct fans tosuit length and configuration of ducting systems.The unit is ideal for use with in-line centrifugal typefans and compatible accessories. Performanceof HR500EP and HR500IP: Up to 244 l/s FIDcapacity (balanced airflow Ideal for computerrooms, classrooms, offices and the health & leisureindustries.EP UnitHole opening: 610 x 381mmFrom atmosphereTo atmosphereModelGENModel Stock Ref £ TradeHR500IP 370447 489.14HR500EP 370451 454.78Spigot Sets200mm Spigot setGENStock Ref£ Trade+ 434806 45.24+ 434805 45.24250mm Spigot setGENStock Ref£ Trade+ 434806 45.24+ 434805 45.24315mm SpigotGENStock Ref£ Trade+ 434806 45.24480 - 750Dimensions (mm)EP & IP UnitWeight: 9kgHole opening: 610 x 381mmThermal Efficiency GraphExtract fromdwellingPlanSupply todwelling120 22070 15530 90IP UnitSupply todwellingExtr act fromdwelling2 ØØ3 Ø5 Ø480 - 750AdditionalSpigots434806 (Setof 2)AdditionalSpigots434805(Set of 2)340ToatmospherePlanFromatmosphere600End Elevation108 T: 0844 856 0590


ØØ250300315ØMVHR UnitsHR500DPPassive MVHR UnitFeatures & Benefits Passive - no fans Lightweight, compact and easy to install Up to 70% heat recovery Easy to cleanA ‘stand alone’ heat exchange module which willtransfer up to 70% of the outgoing heat to incomingair. Polymeric construction with spigots to suit 200,250 and 315mm Ø flexible ductwork.Module accessible for routine cleaning.Condensate outlet provided. Ideal for use in airconditioned environments.PerformanceHeat Exchange Resistance GraphThe heat exchanger works at the same highefficiency, automatically keeping a cool room cool.Performance of the Heat Exchange Unit: At 180l/sachieves 70% temperature efficiency (balancedairflow). Ideal for schools, pubs, offices and leisureindustries.Dimensions (mm)Weight: 10kg700Additionalspigots105 78 315(Set of 4)Additionalspigots105 77 315(Set of 4)Heat ExchangeUnit105 38 290ModelHR500DPINDStock Ref£ Trade10538290 518.61200mm Spigot setsINDStock Ref£ Trade+10577315 86.50+10578315 86.50250mm Spigot setsINDStock Ref£ Trade+10577315 86.50+10578315 86.50315mm Spigot setsINDStock Ref£ Trade+10577315 86.50Plan120703022015590Thermal Efficiency Graph200Ø105 77 315(Set of 4)105 78 315(Set of 4)340600W: www.vent-axia.com 109


Ducting & FittingsSince 1936, <strong>Vent</strong>-<strong>Axia</strong> have been known forproviding a complete ventilation solution. Thishas not changed, and now we offer one of thewidest ranges of ancillaries available today.Range110 T: 0844 856 0590


W: www.vent-axia.com 111


Ducting & AccessoriesSystem 60 204 x 60 System 54 110 x 54 System 25 225 x 25CBABCABCACCABADBCCBACBADBACDBACDBACBACCBA(mm) Pressure loss Pa (mm) Pressure loss Pa (mm) Pressure loss PaDescription Dimension 15 1/s 30 1/s 60 1/s Dimension 15 1/s 30 1/s 60 1/s Dimension 15 1/s 30 1/s 60 1/sFlat ChannelConnectorFHorizontal 90ºBendF to FHorizontal 45ºBendM to FHorizontal TPieceFFFVertical 90ºBend F TO FVertical 45ºBendF to FElbow bendwith 100mmSpigotF to M spigotElbow bendwith 125mmSpigotF to M spigotElbow bendwith 150mmSpigotF to MElbow bendwith 100mmSocketF to FFlat Channelconnectorwith DamperA 206 0.8 2.3 7.8 111 2.7 9.8 32.0 236 7.2 25.0 86.0B 63 56 29C 1500 Stock Ref 1500 Stock Ref 1500 Stock Ref436617 436599 436632A 212 0.11 0.4 1.5 115 0.31 1.4 6.4 240B 65 58 34C 100 Stock Ref 75 Stock Ref 80 Stock RefBAS 436623 436605 436639A 212 1.9 8.4 34.0 117 9.9 40.0 162.0 240 10.2 37.0 139.0B 65 60 34C 262 Stock Ref 152 Stock Ref 289 Stock Ref436620 436602 436635A 212 0.7 2.2 13.0 240 7.6 26.0 94.0B 65 34C 92 Stock Ref 119 Stock RefBAS 249944 462195A 212 vary on installation 117 vary on installation 240 vary on installationB 65 60 34C 310 184D 259 Stock Ref 149 Stock Ref436551 436614A 115 2.6 10.0 45.0 116 15.7 63.0 251.0 5.4 20.0 73.0B 115 96C 60 Stock Ref 60 Stock Ref Stock RefBAS 436621 436603 436636A 209 0.5 2.6 13.2 116 2.6 12.7 63 240 4.6 8.6 30.0B 65 82 34C 95 Stock Ref 100 Stock Ref 69 Stock Ref445196 441655 441656A 212 7.3 29.0 117.0 117 8.2 33.0 137.0 240 8.0 32.0 126.0B 65 60 54C 212 140 158D 85 91 55DØ 102 (M) Stock Ref 100 (M) Stock Ref 100 (M) Stock RefBAS 436624 436607 436640A 212 6.2 26 109B 65C 212D 85DØ 125 (M) Stock Ref436625A 212 5.2 22 67B 65C 212D 85DØ 150 (M) Stock RefBAS 436626A 117 8.2 33.0 137.0B 60C 140D 72Ø 102 (F) Stock Ref- 436608A 115 20 21.4 49B 58C 75 Stock RefGEN - 400735112 T: 0844 856 0590


Ducting & fittingsBBCCCBCBCDACAAAAABAACCACAACB*System 60 AirGrille Adaptor issupplied with theSingle Air BricksCCBBBBDBABSystem 60 204 x 60 System 54 110 x 54 System 25 225 x 25(mm) Pressure loss Pa (mm) Pressure loss Pa (mm) Pressure loss PaDescription Dimension 15 1/s 30 1/s 60 1/s Dimension 15 1/s 30 1/s 60 1/s Dimension 15 1/s 30 1/s 60 1/sClip 225 x 25onlyClipDrop downsectionF to FA 30.4B 40.5C 10.8 Stock RefA 60.5 117B 20.5 10C 210 Stock Ref 60 Stock RefBAS 436622 400745A 231B 207C 120D 54 Stock Ref442273436638*Single Air A 221 7.3 28.0 108.0 221 7.3 28.0 108.0 221 7.3 28.0 108.0Brick B 65 65 65Horizontal C 55.5 Stock Ref 55.5 Stock Ref 55.5 Stock RefWhite BAS 370336 436610 436610Terracotta 5107197 436612 436612Brown 372210 436611 436611Beige 372101 436613 436613A 221 5.3 21.0 80.0 221 5.3 21.0 80.0Single Air GrilleSoldierB 65 65C 15 Stock Ref 15 Stock RefWhite 438594 438594Terracotta 468728 468728Brown 468730 468730Beige 468729 468729A 235 14.8 62 103DoubleAir BrickB 141C 75 Stock RefWhite BAS 438604Terracotta 438607Brown 438605Beige 438606Double AirBrickAdaptorAir GrilleAdaptorFlexible ductingFlat ChannelEnd CapLouvred Grillewith FlyscreenfittingFlat ChannelWall PlateA 228 44B 132C 86 Stock Ref438608A 212 1.2 4.8 17.9 240 8.0 9.0 24.0B 65 65C 60 Stock Ref 100 Stock RefBAS 436609 436642A 3000B 204C 60 Stock Ref5109662A 50.6B 10.4C 111 Stock RefGEN 400733A 140 20 76 288B 50C 140 Stock Ref400743A 150B 3C 150 Stock RefBAS 436606W: www.vent-axia.com 113


Ducting & AccessoriesDucting & fittingsC DBA EC DBA EC DBA EøCBøAB ACA BCABCACBAC BBCASystem 100 100 Ø System 125 125 Ø System 150 150 Ø(mm) Pressure loss Pa (mm) Pressure loss Pa (mm) Pressure loss PaDescription Dimension 15 1/s 30 1/s 60 1/s Dimension 15 1/s 30 1/s 60 1/s Dimension 15 1/s 30 1/s 60 1/sRound toRectangularAdaptor100mmsocketF TO MRound toRectangularAdaptor125mmF TO MShort Round toRectangularAdaptor100mmsocketF TO MReducer Cone100mm to125mmRound 2mDucting lengthInsulated/uninsulatedEqual TeeInsulated/uninsulatedMMM90º BendInsulated/uninsulatedMM45º BendInsulated/uninsulatedMMConnectorUninsulatedMMReducer150 to 125A 204 1.9 4.9 14.5 117 4.8 20.5 86.3 240 3.8 14.9 57.4B 60 60 34C 290 182 305DØ 125 104 104E 45 Stock Ref 45 Stock Ref 35 Stock RefGEN 441654 400740 425497A 212 0.71 2.95 11.5B 65C 220DØ 127E 45 Stock Ref370127A 117 4.8 20.4 86B 60C 65DØ 100E 30 Stock RefGEN 455035A 125BC 100 Stock Ref466783A(ID)Ø 103 1.01 2.82 6.2 125 0.41 1.4 3.8 150 0.21 0.8 2.42B(OD)Ø 106 129 154C 2000 Stock Ref 2000 Stock Ref 2000 Stock RefGEN 5108249 428630 51082515108250 434715 5108248A(ID)Ø 97 vary on installation 121.11 vary on installation 147.55 vary on installationB(OD)Ø 100 125.09 151.58C 189 Stock Ref 212.37 Stock Ref 238.96 Stock Ref372012 428636 372075372007A(ID)Ø 97 5.61 21.15 80.21 121.18 2.01 8.42 34.9 143.74 1.04 4.21 18.22B(OD)Ø 100 125.36 149.27C 123 Stock Ref 271.49 Stock Ref 327.86 Stock RefGEN 372010 428635 372076372004 427360 370295A(ID)Ø 94 2.11 8.24 31.41 120.94 0.72 2.91 12.18B(OD)Ø 99 123.3C 171 Stock Ref 189.34 Stock Ref372011 431590372005 441657A(ID)Ø 96 0.92 4.2 20.44 119.98 0.21 0.92 4.31 146.57 0.1 0.2 1.1B(OD)Ø 99 124.92 151.77C 59 Stock Ref 58.57 Stock Ref 61.37 Stock RefGEN 372006 428633 370299A 60 0.6 2.2 8.8 60 0.6 2.2 8.8BØ 125 150 150CØ 100 Stock Ref 125 Stock Ref 125 Stock RefVA54119 428632 428632114 T: 0844 856 0590


Ducting & AccessoriesDucting & fittingsPVC Flexible DuctingBASPVC with wire helix. Used with Single Spigots, andin multi-duct schemes.6 metre lengthDuct Dia Stock Ref100mm 436580125mm 436584150mm 436588200mm 436592T-Series Flexible DuctingGENPVC with wire helix. For use with T-Series. 6m length.Size Duct Dia Stock RefSize 6 175mm 566607Size 7 225mm 566609Size 9 300mm 566612Size 12 400mm 566616Insulated Flexible DuctingInsulated ducting should be used when duct passesthrough an unheated area. Minimized heat losswhen used with heat recovery fans. Available in6 diameters. An additional benefit is that thermallyinsulated duct offers some measure of acousticattenuation.Fire Rating: When assessed against the integritycriterion of BS476: Part 20; 1987, the ductingis capable of providing in excess of 25 minutesintegrity from inside to outside.GEN10 metre lengthsDuct Dia Stock Ref100mm 561654125mm 561655150mm 561656200mm 561658250mm 561660315mm 561662Acoustic Insulated DuctingMultiple layer aluminium/polyester laminate withmicro perforated flexible core to enhance acousticperformance. Core surrounded by 25mm fibreglassinsulation with outer vapour barrier.10 metre lengths GENDuct Size Stock Ref100mm 370172125mm 370173150mm 370174200mm 370175250mm 370176315mm 370178Aluminium Flexible DuctingLightweight, easy to install ducting made of 5 layeraluminium foil/ polyester on a steel wire helix. Thestrength of the helix resists distortion and damagedue to rough handling.Fire Rating: When assessed against the integritycriterion of BS476: Part 20; 1987, the ductingis capable of providing in excess of 39 minutesintegrity from inside to outside. Available in 100,125, 150m 200, 250, 315 and 400mm diametersizes to fit spigot sizes on all modular componentsin the Airtrak range, (except ACP300).10 metre lengths INDDuct Dia Stock Ref100mm 10539100125mm 10539125150mm 10539150200mm 10539200250mm 10539250315mm 10539315400mm 10539400Duct Y PiecesGENFor dividing a ventilation system, providing ductingto multiple supply or extract grilles using only asingle fan source.Stock Ref 2x Into 1x452081 100mm 100mm452082 100mm 150mm455211 125mm 125mm455212 125mm 150mm452083 150mm 150mm452084 150mm 200mm452085 200mm 200mm452078 200mm 250mm452080 200mm 350mm452076 250mm 250mm452079 250mm 300mm452077 300mm 300mm3-Way SplittersINDManufactured from high impact polymeric materialwhich is flame retardant with a maximum operatingtemperature of +50˚C.Stock Ref.10551250Stock Ref.10553400W: www.vent-axia.com 115


Galvanised Spiral Wound DuctingDucting & fittingsSpiral Ductwork - 3 m lengthGENSubject to carriage charge of £20 on orders below£200Duct Size Stock Ref100 Ø 400900125 Ø 400901150 Ø 400902200 Ø 410922250 Ø 410923315 Ø 410924Equal TeeDuct Size Stock Ref100 Ø 400749125 Ø 400750150 Ø 400751200 Ø 370238250 Ø 370239315 Ø 410925GENFemale CouplerDuct Size Stock Ref100 Ø 400755125 Ø 400756150 Ø 400757200 Ø 410927250 Ø 410928315 Ø 410929GENJoining PieceGENIn sheet metal. For joining lengths of flexible ductingto give long lasting airtight connection.Duct Size Stock Ref100 Ø 561804125 Ø 561805150 Ø 561806200 Ø 561808250 Ø 561810315 Ø 561813Flanged SpigotDuct Size Stock Ref100 Ø 400761ReducerDuct Size Stock RefR125/100 370302R150/100 370303R150/125 370304R200/150 370307R250/200 370309R300/100 370310R300/200 370312GENGEN90˚ BendDuct Size Stock Ref100 Ø 400752125 Ø 400753150 Ø 400754200 Ø 370202250 Ø 370203315 Ø 410926GENBalancing DamperDuct Size Stock Ref100 Ø 400758125 Ø 400759150 Ø 400760200 Ø 410930250 Ø 410931315 Ø 410932GEN116 T: 0844 856 0590


Grilles & DiffusersDucting & fittingsCircular Exhaust DiffusersGENManufactured from polypropylene plastic. Suitablefor exhausting air and can be fitted directly to theduct or in the ceiling.Duct Size Stock Ref100 Ø 10544100125 Ø 10544125150 Ø 10544150200 Ø 10544200Circular Supply DiffusersGENManufactured from polypropylene plastic. Suitablefor supplying air and can be fitted directly to theduct or in the ceiling.Duct Size Stock Ref100 Ø 10543100125 Ø 10543125150 Ø 10543150200 Ø 10544200Aircheck H40/70 - Bathroom GENAn auto humidity operated extract grille. Constantairflow of 40m 3 /h, opening to 70m 3 /h whenoperated.Stock Ref455204Aircheck H65/120- Kitchen/Utility GENAn auto humidity operated extract grille. Constantairflow of 65m 3 /h, opening to 120m 3 /h whenoperated.Stock Ref455206Aircheck Ceiling adaptor(CA125)GENA ceiling adaptor for connection between Aircheckgrilles and ducting.Stock RefCA125 455219Unitex Wall TerminalsGENExternal weather louvre, wall sleeve and ductconnection spigot in one unit. Satin anodised louvregives full weather protection Brown epoxy powdercoated finish, weather louvre available as optionalextra (finish to BS08B29). 280mm or 80mm wallsleeve section.80mm wall sleeve150mm200mm250mm315mmStock RefSA150/80SA200/80SA250/80SA315/80280mm wall sleeve Stock Ref150mm SA150/280200mm SA200/280250mm SA250/280315mm SA315/280Aircheck A15/40 - WCGENElectrically operated extract grille. Constant airflowof 15m 3 /h, opening to 40m 3 /h when electricallyoperated.Stock Ref455207Aircheck A65/120 - KitchenGENElectrically operated extract grille. Constant airflowof 65m 3 /h, opening to 120m 3 /h when electricallyoperated.Stock Ref455208External Terminationslouvre Grilles with SpigotGENPlastic louvre grilles with either 100mm or 150mmdiameter spigots.100mm Ø Stock RefRD104TC 370328RD104BR 370329RD104WH 370330150mm Ø Stock RefRD604BR 370337RD604TC 370338RD604WH 400742Collar for Exhaust &Supply DiffusersStock Ref371301SPW: www.vent-axia.com 117


AccessoriesDucting & fittingsDiffuser with integralFire Damper (Supply)Duct Size Stock Ref100 Ø 370249GENIntumescent FirewrapRectangular PVC ductingDuct Size Stock Ref110 x 54 435137204 x 60 435138225 x 25 467790GENFlexible SilencerGENFlexible silencer unit for use as part of a ductedsystem for noise reduction. 100mm diameterconnections.Stock RefFS100 370426Diffuser with IntegralFire Damper (Extract)Duct Size Stock Ref100 Ø VHD100125 Ø VHD125150 Ø VHD150GENIntumescent Fire CollarGENIntumescent fire collar with stainless steel casingsuitable for PVC ducting in timber framed building.Rectangular DuctingDuct Size Stock Ref110 x 54 435131204 x 60 435132225 x 55 435133Circular Ducting Fire CollarDuct Size Stock Ref100mm Ø 435134125mm Ø 435135150mm Ø 435136GENResettable Fire DampersDuct Size Stock Ref100 Ø 400788125 Ø 400789150 Ø 400790Flame Retardant FilterDuct Size Stock Ref100 Ø 400776Attenuated DuctStock Ref1000mm 449369(Requires adaptor kit for 204 x 60)500mm 449368(Requires adaptor kit for 204 x 60)Aadaptor kit for 204 x 60Stock Ref403032GENGENGENAcoustic MatGEN25mm thick foam mat for use as a resilient mountingfor wholehouse units.Stock RefACM/House 370179220 x 90 High flowrectangular ductStock RefElbow bend 403027with rotating offset spigot to 100mm roundElbow bend 449361with rotating offset spigot to 125mm roundElbow bend 449362with rotating offset spigot to 150mm roundHorizontal T 449365Flat Channel Connector 403026Channel Fixing Clip 403030Flat Channel Duct 1m 403024Flat Channel Duct 1.5m 403025Round Adaptor 403031220 X 90 to 150MMHorizontal 90 degree bend 403028Horizontal 45 degree bend 449363Vertical 90 degree bend 403029Vertical 45 degree bend 4493643M Flexible rectangular duct 449366BAS<strong>Vent</strong>-<strong>Axia</strong> does not guarantee compliance with Building Regulations Part B, Fire Spread or other regulations that relate to fire planning. Suitabilityto comply with these regulations should be determined prior to installation and in conjunction with Building Control Officers. Compliance with theRegulations is specifically excluded from quotations and designs.118 T: 0844 856 0590


100mm & 150mm AccessoriesDucting & fittingsWall Fitting KitDOMA range of VA100mm and VA150mm wall kits. Forinstalling into most walls using the telescopic linerssupplied.WhiteModelStock RefVA100 254102VA140/150 140902Silhouette 150 140902BrownDuct Size Stock RefVA100 254100VA140/150 140903Silhouette 150 140903Termination SetGENUsed as a decorative inlet grille or soffit terminationset in conjunction with 100mm or 125mm diameterducting. Two fixing screws supplied to secure grilleto the spigot through material up to 25mm thick.Dimension 155mm x155mm.Colour:Material:Stock Ref563513White.ABS plastic.Terminal Connector & GrilleGENUsed for the termination of 100mm flexible ductingto the ceiling or wall of small areas, such as internaltoilets.Connector: manufactured in flame-retardant highimpact thermoplastic.Colour: Grey.Grille: ABS plastic eggcrate, white finish.Description Stock RefGrille 560846Connector 560856Window Fitting KitDOMFor use in single or sealed double glazing and mostmaterials up to 40mm thick.Decoration FrameGENA decoration frame that converts old Centrif to newCentrif Duo without the need to redecorate. Theframe can be used with Quadra and Centrif DuoPlus.The frame is simply installed using two wall fixingscrews, allowing the fan to be mounted via itsstandard mountings. Finished in a high mouldedmaterial plastic colour matched to the fan.100mm Wind CowlGENWind baffle for high rise, coasted or exposedareas.WhiteColorWhiteColourStock RefModelStock RefVA100 (105Ø) 254101VA100 (110Ø) 443234SizeStock Ref442551386mm x 296 x 32 mm deepWhite 457845Centra/Sil 100 442947VA140/150 140901Solo 11461685W: www.vent-axia.com 119


100mm & 150mm AccessoriesAir GrilleGENLouvre grille for external termination of 100mmdiameter rigid ducting. Consists of wall mountingpiece and grille with 2 fixing screws.Colour: White or Brown.Dimensions: 155 x 155 x 32mm.Material: ABS plastic.Colour Stock RefWhite 563511Brown 563500Tamper Proof Window KitDOMTamper proof window kit for use with theVA140/150 fan range.Stock Ref459664Ducting PackDOMConsists if 1 x 3 metre length aluminium foil flexibleducting of 100mm diameter, 2 x cable ties and 1x 100 diameter spigoted fixed grille with built-inscreen.Stock Ref563517Quick Fit 100mm Airflow Shutter DOMShutter with gravity flaps to protect againstbackdraught. The spigot connects to 100mm rigidducting using quick fix grips provided.Dimensions: 155 x 155 x 20mm.Material plasticColour Stock RefWhite 563522Brown 563542Quick Fit 100mm GrilleDOMTerminates a rigid duct on an outside wall usingthe ‘quick fix’ side grips without the need of furtherfixings.Colour Stock RefWhite 563521Brown 563541Quick Fix TerminationGENThe quick fix termination is designed to be installedfrom inside the building to a nominal 117mm or165mm diameter core-cut hole, saving time andcost. Four sealing rings asures a weather tight fit tothe wall external leaf. Effective length 370mm. Foruse with centrifugal fans only.Duct Size Stock Ref100mm 563535150mm 434656120 T: 0844 856 0590


Ducting & fittings<strong>Vent</strong> CowlGENExternal termination for 100mm diameter rigidducting through roofs and walls in exposedsituations. Overall diameter 200mm. Not suitablefor use with flexible ducting.Material: Stock RefGrey PVCu. 561403Wind BafflesGENA range of 100mm and 150mm weather baffles.Cowled wall outlet with damper protected gravitygrille.Available in white and brown they are ideal forexposed coastal applications, helping to preventunwanted backdraughts.100mmColourStock RefWhite 452094Brown 452095150mmColourStock RefWhite 452096Brown 452097Condensation TrapGENCondensation trap, for fitting in vertical rigid PVCupipe ducting. Must be used where pipe ducts passthrough unheated roof voids. Fitted with 20mm pipeconnection for running off condensate. Not suitablefor use with flexible ducting.LengthMaterial:85mmGrey PVCu.SizeStock Ref100mm 563516125mm 455191150mm 455190Air replacement SetGENBathroom and toilet ventilation is only effectivewhen there is adequate air replacement into theroom. This is often most effectively achieved byfitting a pair of air replacement grilles at low level ina door. Consists of a two piece telescopic set whichfits unobtrusively on either side of the door panel.VA1405/150 Window wind cowl GENWind baffle for exposed areasStock Ref455262Minimum fixing thickness:30mm.Dimensions:454 x 90mm.Hole size:435 x 76mm.Material:High impact thermoplastic.Free area. 115cm 2ColourStock RefIvory 561401Brown 561400W: www.vent-axia.com 121


CommercialRangeLo-CarbonT-Series ®The UK’s No. 1 Commercial Fan is availablewith a low energy DC motor providing up to65% energy saving. The motor is designedto provide longer life, improved performance,lower running costs and maintain the T-Seriesrugged reliability.Range122 T: 0844 856 0590


The UK’s number one provider ofcommercial ventilation solutionsW: www.vent-axia.com 123


Commercial RangeACM® 100-200In-Line Mixed FlowFans ModelsFeatures & Benefits Quietest on the market Designed and manufactured in UK Two speed selectable motor Timer versions available Removable motor core assembly Rotating motor chassis assembly Supplied complete for installation IP44 rated Aesthetically pleasing with wipe cleanpolymerDucted <strong>Vent</strong>ilation<strong>Vent</strong> <strong>Axia</strong> has designed a complete range ofenergy efficient Mixed Flow In-Line fans that arenow quieter, offer two and half times the pressureof conventional axial fans and are dimensionallymore compact making them ideal for many ductedapplications.The ACM Mixed Flow In-Line fan can operate inboth horizontal and vertical positions.MotorAll motors are fitted with Standard Thermal OverloadProtection (S.T.O.P.). Designed for ambienttemperatures up to +50°C. All sizes with capacitorrun motors. All sizes are Class II appliances. Supplyvoltage 220-240V/1/50Hz.These units have a separate footplate for simplelocation mounting and detachable spigots for simpleconnection to ducting. The motor body chassis nowrotates to provide connection in acute spaces.Cleaning the product has also become simple as allparts can be removed without removing the ducting.GENControllerFor optimum performance use a <strong>Vent</strong>-<strong>Axia</strong> 1.5 ampelectronic controller. Surface mounted providingvariable speed control with an On/Off/sensorslider with indication light. There is an adjustableminimum speed setting. The controller has electricalconnections for use with suitable external sensors.Cannot be used with timer models.1.5 Amp Controller (Suitable for 100mm –200mm models) Dimensions: 86 x 156 x 53mm(H x W x D).Stock Ref£ TradeW300310 80.49For flush fitting a metal wall box accessory isavailable.Stock Ref£ Trade400144 9.72Hole for wall box: 80 x 150 x 150mm (H x W x D).ModelsGENModel Stock Ref £ TradeACM100 17104010 117.60ACM100T 17104020 145.85ACM125 17105010 146.57ACM125T 17105020 146.57ACM150 17106010 178.81ACM150T 17106020 218.00ACM200 17108010 263.03ACM200T 17108020 320.67Dimensions (mm)Size 100 125 150 200AØ 97 122 147 199.5BØ 178 178 200 223C 124 124 138 146D 298 259 350 300E 96 96 118 130F 168 168 192 195G 120 120 162 100H 153.5 153.5 178 180GDAHFBCEPerformanceStatic Pressure PaStatic Pressure Pa17515012510075502502502001501005001ACM100 - 1253 2 40 25 50 75 100Air Volume l/s5ACM150 - 200760 50 100 150 200 250Air Volume l/sNominaldB(A)Size Curve r.p.m l/s @ Pa Watts Amps at 3m1 L 1670 52 18 0.09 2010012 H 2200 71 23 0.1 2313 L 1800 65 25 0.12 2012514 H 2400 91 30 0.13 2415 L 1870 123 42 0.19 3115016 H 2350 145 48 0.21 3517 L 1650 170 114 0.51 3220018 H 2250 240 107 0.48 388124 T: 0844 856 0590


Commercial RangeACM® 250-315In-Line Mixed FlowFans ModelsFeatures & Benefits Available in two sizes Simple Installation Supplied complete for installation Optimise fan performance by using anapproved <strong>Vent</strong> <strong>Axia</strong> controller Diagonal impeller with stator Galvanized metal housing Integrated thermal switch Includes a mounting bracket Designed to meet IP54Ducted <strong>Vent</strong>ilation<strong>Vent</strong> <strong>Axia</strong> has designed a complete range ofenergy efficient Mixed Flow In-Line fans that arenow quieter than any other product on the market.ACM is now in a range of six products in the rangewhich have been designed for use with rigid andflexible ducting.In Line Mixed Flow fans offer two and half timesthe pressure of conventional axial fans and aredimensionally more compact making them ideal formany ducted applications.The ACM Mixed Flow In-Line fan can operate inboth horizontal and vertical positions and can bemounted to meet its optimum performance.MotorAll motors are fitted with Standard ThermalOverload Protection (S.T.O.P.). Designed forambient temperatures up to +50°C. All sizes withcapacitor run motors. ACM 250 and 315 are ClassI appliances. Supply voltage 220-240V/1/50Hz.ModelsGENModel Stock Ref £ TradeACM250 17110010 387.37ACM315 17112010 443.39ControllerFor optimum performance use a <strong>Vent</strong>-<strong>Axia</strong> electroniccontroller. Surface mounted providing variablespeed control with an On/Off/sensor slider withindication light. There is an adjustable minimumspeed setting. The controller is radio suppressed toBS EN 55014 and electrical connections for usewith suitable external sensors are provided.1.5 Amp Controller – Suitable for 250mm modelDimensions: 86 x 156 x 53mm (H x W x D).GENStock Ref£ TradeW300310 80.49Used in conjunction with speed controllable fansto provide 5 stepped speed without electronicmotor ‘hum’. Several fans can be connected to onetransformer provided their combined load does notexceed the controller rating.Single phase: 3.0amp. Rotary switch giving On/Off and five speeds.Output voltages at 240V/1PH/50Hz 0, 90, 115,140, 175, 240 volts.Neon indicator. Enclosures are protected to IP54.Dimensions: 135 x 170 x 117mm (H x W x D).INDStock Ref£ Trade10314103 177.66Dimensions (mm)296 + - 2278 + - 1258.8 + - 2Ø250 + - 1ACM250335.5 + - 2307.6 + - 2318.5 + - 2Ø315ACM315PerformanceACM200 - 3157006002500Static Pressure Pa400130020010000 100 200 300 400Air Volume l/sNominaldB(A)Size Curve r.p.m l/s @ Pa Watts Amps at 3m250 1 H 2720 450 145 0.8 52315 12 H 2840 653 270 1.2 56W: www.vent-axia.com 125


PowerflowIn-Line Duct Fans ModelsFeatures & Benefits Tough plastic in-line range in eight models 50-80mm long ribbed spigots Flame retardant casing All models speed controllable Fitted with Standard Thermal OverloadProtection (S.T.O.P.) For the best performance from yourfan, use a <strong>Vent</strong>-<strong>Axia</strong> controller IP44 RatedDucted <strong>Vent</strong>ilationPowerflow models provide a compact yet versatilerange designed with the installer in mind, combiningthe acoustic benefits of a tough plastic casing withthe pressure characteristics of a centrifugal fan.A range of eight models from 100 to 315mmdia. duct sizes. The 315mm dia. model has beenspecifically developed for use with rigid ductwork.Air volumes from 59l/s to 420l/s in free air andcapable of pressure development up to 550 Pa.Powerflow has 50-80mm long inlet and dischargespigots allowing easy installation and fixing. Theadjustable mounting foot allows the terminal box tobe rotated to any angle and allows plenty of spaceand adjustment for screw fixing. The robust fireretardantpolymeric casing combined with internalguide vanes ensures optimum airflow managementthrough the unit.ElectricalMotors are 220-240V single phase 50Hz.Capacitor start and run. The terminal box is integralwith the case moulding. All motors are fitted withStandard Thermal Overload Protection (S.T.O.P.).Motor/ImpellerAll models are fitted with an external rotor motorand backward curved impeller assembly for longlife and reliability.All sizes are IP44 according to BS EN 60529. Ballbearings are greased for life and designed to runat any angle. Insulation is Class ‘B’ (from -30˚C to+40˚C). Manufacture is controlled to BS EN ISO9001.ModelsGEN2 Pole In-Line Duct Fan - Single PhaseStock Ref£ TradeACP10012 192.56ACP12512 207.69ACP15012 215.63ACP16012 215.63ACP20012 294.22ACP25012 380.88ACP31512 443.46ACP31512HP 459.65IND2.5A Electronic ControllerOn/Off indication light. Infinitely variable speedcontrol. Adjustable minimum speed setting andoptional sensor mode. The controller is radiosuppressedto BS800 and rated at 2.5 amps.Stock Ref£ TradeW10303102M 80.87Dimensions (mm)Dia Øa b c d e Øf g h Weight100 100 146 287 52 52 254 110 270* 2.2125 125 146 287 60 60 254 110 270* 2.2150 149 175 287 52 52 301 110 270* 3.1160 160 175 287 52 52 301 110 270* 3.1200 200 193 290 47 47 344 92 130 4.3250 250 218 312 65 65 367 92 130 4.6315 315 250 366 76 76 405 92 130 5.9315HP 315 250 366 76 76 405 92 130 6.1*Sizes 100, 125, 150 & 160 have a flat mounting foot126 T: 0844 856 0590


Commercial RangePerformance CurveSTATIC PRESSURE PaPerformance Data5004504003503002502001501004501 2 35 6 7 800 50 100 150 200 250 300 350 400 500 l/sVOLUME0 200 400 600 800 1000 1200 1400 1600 m3/hCurve Nominal l/s @ Pa S.C. F.L.C. dB(A)Dia. Ref. r.p.m 0 25 50 100 150 200 250 300 350 400 Watts Amps Amps at 3m100 1 2740 59 56 52 46 39 31 21 83 0.85 0.34 35125 2 2410 78 73 69 60 50 39 27 86 0.85 0.34 35150 3 2520 137 130 122 106 89 73 57 39 100 1.10 0.43 45160 4 2520 137 130 122 106 89 73 57 39 100 1.10 0.43 45200 5 2620 234 224 214 194 177 159 138 119 100 82 150 1.52 0.68 47250 6 2720 290 283 270 250 234 216 197 177 156 124 185 1.60 0.77 48315 7 2720 339 329 313 274 244 218 191 161 131 98 182 1.57 0.75 51315HP 8 2667 420 410 400 380 350 330 300 270 247 222 300 4.00 1.30 52Acoustic Sound Power LevelStock Ref. 63 125 250 500 1K 2K 4K 8K @3mACP10012 INLET 81 84 75 68 61 52 46 40 51ACP10012 OUTLET 82 84 77 68 61 52 49 43 52ACP10012 BREAKOUT 52 48 57 53 53 48 40 38 35ACP12512 INLET 80 79 76 70 61 57 51 45 51ACP12512 OUTLET 82 80 76 71 61 54 51 43 52ACP12512 BREAKOUT 52 48 57 53 53 48 40 38 35ACP15012 INLET 79 84 84 76 69 65 61 52 59ACP15012 OUTLET 78 84 83 74 69 65 60 50 58ACP15012 BREAKOUT 59 62 66 62 62 58 51 43 45ACP16012 INLET 81 81 79 76 66 61 58 49 55ACP16012 OUTLET 80 82 81 73 67 62 57 49 54ACP16012 BREAKOUT 59 62 66 62 62 58 51 43 45dBAdBAStock Ref. 63 125 250 500 1K 2K 4K 8K @3mACP20012 INLET 80 79 74 76 67 65 66 60 57ACP20012 OUTLET 79 79 74 71 69 69 65 59 55ACP20012 BREAKOUT 54 70 67 66 62 59 53 43 47ACP25012 INLET 84 80 74 74 69 69 67 63 57ACP25012 OUTLET 75 79 73 72 72 73 68 64 59ACP25012 BREAKOUT 60 71 70 66 65 62 55 44 48ACP31512 INLET 84 80 74 74 69 69 67 63 56ACP31512 OUTLET 75 79 73 72 72 73 68 64 59ACP31512 BREAKOUT 72 71 73 71 66 63 55 45 51ACP31512/HP INLET 63 72 75 77 79 75 74 67 63ACP31512/HP OUTLET 65 73 76 79 76 80 74 68 64ACP31512/HP BREAKOUT 61 68 69 71 68 67 58 51 52W: www.vent-axia.com 127


Commercial RangeLo-CarbonT-Series®Window ModelsFeatures & Benefits Reduces your carbon footprint Extract/intake model in 2 sizes:9” and 12” Long life Lo-Carbon motor lasts twice aslong as conventional motors Up to 70% energy saving Wired or Wire-less fan models available Easy fit connector Top Socket, standard onall modelsUK’s No. 1 Commercial FanThe Lo-Carbon T-Series range is fitted with alow energy DC motor, developed to improveperformance, lower running costs and maintainT-Series’ rugged reliability.Designed for installation through single or doubleglazing and material up to 32mm thick. Greaterthicknesses can be accommodated using extendedfixing rod sets. Alternatively, the Lo-Carbon T-Seriesrange can be used in conjunction with <strong>Vent</strong>-<strong>Axia</strong>ventilation accessories in flexible and rigid ductingsystems to suit individual requirements. The fancan also be mounted in a fixing plate on walls orabove ceilings.Instantaneous ShutterWith energy saving in mind, units are suppliedcomplete with an integral instantaneous automaticlouvre shutter concealed behind the interior grille.It operates on both extract and intake and at anyangle of mounting.ModelsGENWired ModelSize Stock Ref £ Trade9” Window 456165 411.6112” Window 456173 574.42GENWire-less ModelSize Stock Ref £ Trade9” Window 456169 465.5912” Window 456177 649.75Designed for use in single or double glazing, mosttypes of glass and materials up to 32mm thick.Greater thicknesses can be accommodated usingExtended Fixing Rod Sets. Can also be mounted ina fixing plate or wall, in ducts or above ceilings.Extended Fitting Rod setGENSize Stock Ref £ Trade9” 568104 9.1412” 568106 13.31Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ControllersGENModels Stock Ref £ TradeWire-less 455874 99.54Wired 455873 82.98Dimensions (mm)Size Dim. 9 in 12 inA 39 41B 150 177C 304 381D 302 378E 19 19F 54 54Fixing hole Ø 260 337Weight kg 5.35 7.7Controller (W x H x D) 97 x 99 x 32A E F minDCBPerformance Graph10080Static Pressure Pa6040 1220The shutter is electronically controlled by an actuatorwith a damped action giving quiet operation duringinstant opening and closing. The interlockingedges of the shutter blades provide maximum backdraught protection. When the ventilating unit is usedwith the Lo-Carbon T-Series controller, the shuttercan be set open with the fan motor switched Off toprovide natural ventilation without the security risk ofan open window.Performance00 500 1000 1500Air Volume m 3 /hExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel Curve low medium high (high) (med) @ 3m @ 240VLo-Carbon TX9WW - Wire-less/Wired 1 332 (90) 571 (160) 761 (210) 30.8 40 0.35Lo-Carbon TX12WW - Wire-less/Wired 12 660 (185) 1295 (360) 1550 (430) 68.6 46 0.73128 T: 0844 856 0590


Commercial RangeLo-CarbonT-Series®Wall ModelsFeatures & Benefits Long life Lo-Carbon motor lasts twice aslong as conventional motors Reduces your carbon footprint Extract/intake model in 2 sizes: 9” and 12” Up to 70% energy saving Wired or Wire-less fan models available Easy fit connector Top Socket, standard onall modelsUK’s No. 1 Commercial FanBehind the grille of the Lo-Carbon T-Series Wallmodel is a high performance extract/intakeventilating unit designed to fit through most wallthicknesses using the telescopic liner supplied.For walls of exceptional thickness additionalliners can be used. Conduit entry is provided forconcealed wiring.ElectricalMotor purpose-designed. Suitable for running atany angle. Quiet running. Suitable for operation inambient temperatures from -40°C to +50°C.Fitted with self resetting Standard Thermal OverloadProtection (S.T.O.P.).Supply voltage 220-240V/1/50Hz.Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ModelsWired ModelGENSize Stock Ref £ Trade9” Wall 456166 521.2312” Wall 456174 689.83Dimensions (mm)Size Dim. 9 in 12 inA 391 470B 388 467C 365 442D 375 450E 143 182Weight kg 7.77 10.86Controller (W x H x D) 97 x 99 x 32Centreline of 20mm dia.conduit entry240 min - 315 maxbefore linings part25Centreline of 20mm dia.conduit entryAEBDExternal Brick WallsLo-Carbon T-Series wall models are designed tofit directly into double brick, solid and cavity walls.The two part telescopic liner accommodates wallthicknesses from 240 to 315mm. For thicker wallsadditional liner sections are available. Lo-CarbonT-Series wall models are provided with internal andexternal wall frames which fit flush with both facesof the wall.Instantaneous ShutterLo-Carbon T-Series models are supplied completewith an integral instantaneous automatic louvreshutter which will operate on both intake and extractand at any angle of mounting.When the ventilating unit is used with aLo-Carbon T-Series controller, the shutter can be setopen with the fan motor switched Off to providenatural ventilation without the security risk of anopen window.GENWire-less ModelSize Stock Ref £ Trade9” Wall 456170 589.5612” Wall 456178 780.28Wall Liner SectionSize Stock Ref £ Trade6” 460094 30.027” 460095 34.809” 460096 40.8412” 460086 44.32ControllersPerformanceSPGENModels Stock Ref £ TradeWire-less 455874 99.54Wired 455873 82.98Performance GraphStatic Pressure Pa7060504030201012CHOLE IN WALL C x D00 500 1000 1500Air Volume m 3 /hExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel Curve low medium high (high) (med) @ 3m @ 240VLo-Carbon TX9WL - Wire-less/Wired 1 326 (90) 562 (160) 732 (210) 27 39 0.31Lo-Carbon TX12WL - Wire-less/Wired 12 660 (185) 1355 (360) 1650 (430) 68 48 0.70W: www.vent-axia.com 129


Commercial RangeLo-CarbonT-Series®Roof ModelsFeatures & Benefits Reduces your carbon footprint Extract / intake model in 2 sizes:9” and 12” Long life Lo-Carbon motor lasts twice aslong as other conventional motors Up to 70% energy saving Wired or wireless fan models available New easy fit connector Top Socket,standard on all modelsUK’s No. 1 Commercial FanDesigning ventilation systems with the fan mountedin a skylight or a flat roof is easy. With a low profilecowl, the Lo-Carbon T-Series Roof model is suitablefor installation in horizontal, angled and verticalglass and for fixing plates in roofs. For verticalwindows or walls in exposed areas and singleand double glazing including most types of glassup to 32mm thick. Greater thicknesses can beaccommodated using extended fixing rod sets.Both sizes of <strong>Vent</strong>-<strong>Axia</strong> roof plate assemblies canbe fitted easily into flat roofs.Instantaneous ShutterWith energy saving in mind, Lo-Carbon T-Seriesmodels are supplied complete with an integral,instantaneous, automatic louvre shutter concealedbehind the interior grille.It will operate on both intake and extract and atany angle of mounting. The shutter is electronicallycontrolled by an actuator with a damped actiongiving quiet operation during instant openingand closing.When the ventilating unit is used with aLo-Carbon T-Series controller, the shutter can beset open with the fan motor switched off to providenatural ventilation without the security risk of anopen window.Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ElectricalMotor purpose-designed. Suitable for running atany angle. Quiet running, enclosed. Suitable foroperation in ambient temperatures from -40°C to+50°C.Fitted with self resetting Standard Thermal OverloadProtection (S.T.O.P.).Supply voltage 220-240V/1/50Hz.ModelsGENWired Model Stock Ref £ Trade9” Roof 456168 465.3212” Roof 456176 645.77GENWire-less Model Stock Ref £ Trade9” Roof 456172 526.3412” Roof 456180 730.47GENControllers Stock Ref £ TradeWire-less 455874 99.54Wired 455873 82.98Dimensions (mm)Size Dim. 9 in 12 inA 136 171B 150 177C 304 381D 302 378E 54 54FØ 400 500Fixing Hole 260 337Weight kg 6.22 9.28Controller (W x H x D) 97 x 99 x 32CABEDFØPerformance Graph120100PerformanceExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel Curve low medium high (high) (med) @ 3m @ 240VLo-Carbon TX9RF - Wire-less/Wired 1 313 (85) 562 (155) 693 (190) 27 40 0.34Lo-Carbon TX12RF - Wire-less/Wired 12 518 (143) 1017 (282) 1194 (330) 67 48 0.69Static Pressure Pa806040201 200 250 500 750 1000 1500Air Volume m 3 /h130 T: 0844 856 0590


Commercial RangeLo-CarbonT-Series®Panel ModelsFeatures & Benefits Reduces your carbon footprint Extract / intake model in 2 sizes:9” and 12” Long life Lo-Carbon motor last twice as longas other conventional motors Up to 70% energy saving Wired or wireless fan models available New easy fit connector Top Socket,standard on all modelsUK’s No. 1 Commercial FanLo-Carbon T-Series panel/ceiling models aresuitable for mounting at any angle in internalpartitions, ceilings, ducts and, with louvre grilles,through external walls. When installed only thelouvre grille is visible.Instantaneous ShutterWith energy saving in mind, Lo-Carbon T-Seriesmodels are supplied complete with an integralinstantaneous automatic louvre shutter concealedbehind the interior grille. With a Lo-Carbon T-SeriesController the fan will operate on both extract andintake, suitable for any angle of mounting. Whenthe ventilating unit is used with a Lo-Carbon T-Seriescontroller, the shutter can be set open with the fanmotor switched off to provide natural ventilationwithout the security risk of an open window.Wire-less ControlEvery Lo-Carbon T-Series Wire-less FM Controlleruses unique digital signals to ensure trouble freeoperation. The controller will transmit through wallsand floors allowing complete flexibility of design tocontrol fans up to 30m away.Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ElectricalSuitable for operation in ambient temperatures from-40°C to +50°C.Fitted with self resetting Standard Thermal OverloadProtection (S.T.O.P).Supply voltage: 220-240V/1/50Hz.Easy CleaningIntegrated component design allows all partsto be dismantled for cleaning without the use ofspecialist tools.ModelsGENWired Stock Ref £ Trade9” Panel 456167 434.8712” Panel 456175 599.10Wireless Stock Ref £ Trade9” Panel 456171 491.8712” Panel 456179 677.63GENControllers Stock Ref £ TradeWire-less 455874 99.54Wired 455873 82.98Dimensions (mm)Size 9 in 12 in Size 9 in 12 inA 391 470 GØ 255 334B 388 467 HØ 247 325C 129 152 J 345 422D 39 41 K 309 386E 302 378 L 326 402F 304 381 M 126 164Weight kg: 9mm - 5.13, 12mm - 7.44Controller (W x H x D) 97 x 99 x 32E x F wide19GØHØ22CD180Performance Graph10080JABPerformanceExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel Curve low medium high (high) (med) @ 3m @ 240VLo-Carbon TX9PL - Wire-less/Wired 1 357 (100) 601 (166) 799 (221) 30 41 0.33Lo-Carbon TX12PL - Wire-less/Wired 12 737 (205) 1487 (413) 1761 (490) 67 48 0.70Static Pressure Pa6040201 200 500 1000 1500Air Volume m 3 /hW: www.vent-axia.com 131


Commercial RangeTraditionalT-Series®Window ModelsFeatures & Benefits Extract/intake fans in 4 sizes:6”, 7”, 9” and 12” Patented electronic shutter system ensuresquiet trouble free operation To obtain the best from your fan, use theEcotronic controller Shutter open/fan off mode Low sound levels Easy fit connector Top Socket, standard onall models Designed for single or double glazing up to32mm thickUK’s No. 1 Commercial FanT-Series range is fitted with a <strong>Vent</strong>-<strong>Axia</strong> M-Techmotor, developed to improve performance, lowerrunning costs and maintain the T-Series’ ruggedreliability. A patented speed control pack issimply plugged in one of 3 positions to providelow, medium or boost speed matching the fanperformance to the requirements of the installation.Instantaneous ShutterWith energy saving in mind TX models are suppliedcomplete with an integral instantaneous automaticlouvre shutter concealed behind the interior grille.It operates on both extract and intake and at anyangle of mounting.When the ventilating unit is used with a T-Seriescontroller, the shutter can be set open with the fanmotor switched off to provide natural ventilationwithout the security risk of an open window.Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.Easy CleaningIntegrated component design allows all partsto be dismantled for cleaning without the use ofspecialist tools.ElectricalMotor purpose-designed. Suitable for running atany angle. Quiet running. Suitable for operation inambient temperatures from -40°C to +50°C.Fitted with Standard Thermal Overload Protection(S.T.O.P.).Supply voltage 220-240V/1/50Hz.ModelsWindow ModelsDesigned for use in single or double glazing, mosttypes of glass and materials up to 32mm thick.Greater thicknesses can be accommodated usingExtended Fixing Rod Sets. Can also be mounted ina fixing plate or wall, in ducts or above ceilings.GENModel Stock Ref £ TradeTX6WW W161110 240.69TX7WW W162110 316.54TX9WW W163110 411.61TX12WW W164110 574.42Extended Fitting Rod setGENSize Stock Ref £ Trade6/7/9” 568104 9.1412” 568106 13.31Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 31 31 39 41B 130 130 150 177C 226 265 304 381D 220 258 302 378E 19 19 19 19F 54 54 54 54Fixing hole Ø 184 222 260 337Weight kg 3.57 3.93 5.35 7.7PerformanceExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel low medium high (high) (med) @ 3m @ 240VTX6WW 245 (68) 315 (88) 360 (100) 30 41 0.24TX7WW 305 (85) 395 (110) 485 (135) 40 37 0.24TX9WW 465 (130) 685 (190) 795 (220) 85 43 0.42TX12WW 1095 (305) 1415 (393) 1615 (449) 105 48 0.51A E F minBDC132 T: 0844 856 0590


Commercial RangeTraditionalT-Series®Wall ModelsFeatures & Benefits Extract/intake model in 4 sizes:6”, 7”, 9” and 12” Patented electronic shutter system ensuresquiet, trouble free operation For the very best from your fan use theEcotronic controller Easy fit connector Top Socket, standard onall modelsUK’s No. 1 Commercial FanBehind the grille of the <strong>Vent</strong>-<strong>Axia</strong> T-Series Wallmodel is a range of high performance extract/intake ventilating units designed to fit through mostwall thicknesses using telescopic liners supplied.T-Series also features a unique speed control packwhich enables high, medium or low speed to bepreset to suit room size or required duty.T-Series controllers may be used with this modelto obtain a choice of speeds, reversible airflowdirection and automatic sensor operation. The<strong>Vent</strong>-<strong>Axia</strong> Ecotronic controller gives even greaterrunning economy with its minimum speed settingand ‘E’ mode.Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ShutterTX models are supplied complete with an integralinstantaneous automatic louvre shutter which willoperate on both intake and extract and at anyangle of mounting.When the ventilating unit is used with a T-Seriescontroller, the shutter can be set open with the fanmotor switched off to provide natural ventilationwithout the security risk of an open window.ElectricalMotor purpose-designed. Suitable for running atany angle. Quiet running, enclosed. Suitable foroperation in ambient temperatures from -40°Cto +50°C.Fitted with Standard Thermal Overload Protection(S.T.O.P.).Supply voltage 220-240V/1/50Hz.ModelsWall ModelsDesigned to fit into most double brick walls usingthe telescopic liners, supplied. Additional linersare available to accommodate exceptionallybrick walls.GENModel Stock Ref £ TradeTX6WL W161510 304.38TX7WL W162510 431.23TX9WL W163510 521.23TX12WL W164510 689.83Wall Liner SectionSize Stock Ref £ Trade6” 460094 30.027” 460095 34.809” 460096 40.8412” 460086 44.32Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 310 352 391 470B 303 345 388 467C 290 330 365 442D 290 330 375 450E 104 124 143 182Weight kg 5.54 6.13 7.77 10.86SPPerformanceExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel low medium high (high) (med) @ 3m @ 240VTX6WL 270 (75) 350 (97) 395 (110) 40 43 0.24TX7WL 335 (93) 435 (120) 530 (147) 40 39 0.24TX9WL 515 (143) 755 (210) 870 (241) 85 43 0.42TX12WL 1185 (329) 1530 (425) 1745 (485) 105 49 0.51Centreline of 20mm dia.conduit entry240 min - 315 maxbefore linings part25Centreline of 20mm dia.conduit entryAEBDCHOLE IN WALL C x DW: www.vent-axia.com 133


Commercial RangeTraditionalT-Series®Roof ModelsFeatures & Benefits Extract/intake model in 4 sizes:6”, 7”, 9” and 12” Patented electronic shutter system ensuresquiet, trouble free operation For the very best from your fan use theEcotronic controller T-Series controllers and sensors saveenergy by only switching on the unitswhen you want them to, either manually orautomatically Easy fit connector Top Socket, standard onall modelsUK’s No. 1 Commercial FanWith a low profile cowl, the T-Series Roof modelis suitable for installation in horizontal, angled andvertical glass and for fixing plates in roofs. Forvertical windows or walls in exposed areas andsingle or double glazing including most types ofglass up to 32mm thick. Greater thicknesses can beaccommodated using extended fixing rod sets. Allfour sizes of <strong>Vent</strong>-<strong>Axia</strong> roof plate assemblies can befitted easily into flat roofs.T-Series features a unique speed control pack whichenables high, medium or low speed to be preset tosuit room size or required duty. When used with aT-Series TSC controller, the speed control pack isremoved from the T-Series ventilating unit and fittedinto the 3-pin socket in the back of the controller. The<strong>Vent</strong>-<strong>Axia</strong> Ecotronic controller gives even greaterrunning economy with its minimum speed settingand ‘E’ mode. When using the Ecotronic controllerthe speed control pack remains in the fan.ShutterWith energy saving in mind, TX models are suppliedcomplete with an integral instantaneous automaticlouvre shutter concealed behind the interior grille. Itwill operate on both intake and extract and at anyangle of mounting.When the ventilating unit is used with a T-Seriescontroller, the shutter can be set open with the fanmotor switched off to provide natural ventilationwithout the security risk of an open window.ElectricalMotor purpose-designed. Suitable for running atany angle. Quiet running, enclosed. Suitable foroperation in ambient temperatures from -40°C to+50°C.Fitted with Standard Thermal Overload Protection(S.T.O.P.).Supply voltage 220-240V/1/50 Hz .Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ModelsGENModel Stock Ref £ TradeTX6RF W161210 265.68TX7RF W162210 369.58TX9RF W163210 465.32TX12RF W164210 645.77Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 100 136 136 171B 130 130 150 177C 226 265 304 381D 220 258 302 378E 54 54 54 54F Ø 285 400 400 500Fixing Hole Ø 184 222 260 337Weight kg 3.96 4.89 6.22 9.28ABDECFØPerformanceExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel low medium high (high) (med) @ 3m @ 240VTX6RF 195 (55) 250 (70) 290 (80) 30 41 0.24TX7RF 305 (85) 395 (110) 485 (135) 40 37 0.24TX9RF 465 (130) 685 (190) 795 (220) 85 43 0.42TX12RF 1010 (280) 1305 (362) 1485 (412) 105 48 0.51134 T: 0844 856 0590


Commercial RangeTraditionalT-Series®Panel/Ceiling ModelsFeatures & Benefits Extract/intake model in 4 sizes:6”, 7”, 9” and 12” Colour: soft tone grey Patented electronic shutter system ensuresquiet trouble-free operation For the very best from your fan use theEcotronic controller East fit connector Top Socket, standard onall modelsUK’s No. 1 Commercial Fan<strong>Vent</strong>-<strong>Axia</strong> T-Series Panel/Ceiling models aresuitable for mounting at any angle in internalpartitions, ceilings, ducts and, with louvre grilles,through external walls. When installed only thelouvre grille is visible. The range features a uniquespeed control pack which enables high, medium orlow speed to be preset to suit a specific room sizeor required duty.T-Series controllers may be used with this modelto obtain a choice of speeds, reversible airflowdirection and automatic sensor operation. Whenused with a controller, the speed control pack isremoved from the T-Series ventilating unit and fittedinto the 3-pin socket in the back of the controller.The <strong>Vent</strong>-<strong>Axia</strong> Ecotronic controller gives evengreater running economy with its minimum speedsetting on ‘E’ mode and infinitely variable speedcontrol. For this controller the speed control packremains in the fan.ElectricalSuitable for operation in ambient temperatures from-40°C to +50°C.Fitted with Standard Thermal Overload Protection(S.T.O.P).Supply voltage: 220-240V/1/50Hz.Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ShutterWith energy saving in mind, TX models are suppliedcomplete with an integral instantaneous automaticlouvre shutter concealed behind the interior grille. Itwill operate on both intake and extract and at anyangle of mounting.When the ventilating unit is used with a T-Seriescontroller, the shutter can be set open with the fanmotor switched off to provide natural ventilationwithout the security risk of an open window.ModelsGENModel Stock Ref £ TradeTX6PL W161610 263.70TX7PL W162610 338.94TX9PL W163610 434.87TX12PL W164610 599.10Dimensions (mm)E x F wideSize Dim. 6 in 7 in 9 in 12 inA 310 352 391 470B 303 345 388 467C 117 117 129 152D 32 32 39 41E 220 258 302 378F 226 265 304 381GØ 180 218 255 334HØ 171 210 247 325J 267 306 345 422K 231 270 309 386L 244 282 326 402M 85 104 126 164Weight kg 3.50 3.82 5.13 7.4419GØHØ180B22CDJAPerformanceExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel low medium high (high) (med) @ 3m @ 240VTX6PL 295 (81) 380 (105) 435 (120) 30 41 0.24TX7PL 365 (101) 480 (133) 585 (162) 40 37 0.24TX9PL 565 (157) 830 (230) 960 (267) 85 43 0.42TX12PL 1270 (353) 1640 (456) 1885 (524) 105 44 0.51W: www.vent-axia.com 135


Commercial RangeTraditionalT-Series®Darkroom ModelsFeatures & Benefits Extract/intake models in 4 sizes:6”, 7”, 9” and 12” Specially designed to provide extract/intake ventilation in darkrooms, X-rayareas, etc Patented electronic shutter system ensuresquiet, trouble free operation For the very best from your fan use theEcotronic controller Integrated component design allows allparts to be dismantled for cleaning withoutthe use of specialist tools Easy fit connector Top Socket, standard onall modelsUK’s No. 1 Commercial FanA range designed for photographic, medical,dental and veterinarian applications - used also foropticians and other specialist applications. Mostdarkrooms need a minimum of ten air changes perhour for comfort and efficiency. For rooms containingheat producing equipment (eg: print glazers) ahigher rate of air change may be desirable.The Darkroom model has two cowls, the interiorcowl being designed to give light protection. It canbe installed in windows, partitions, external wallsor roofs. Extended fixing rods for fixing thicknessesup to 370mm are supplied with the unit. Provisionshould be made for adequate air replacementthrough <strong>Vent</strong>-<strong>Axia</strong> non-vision grilles.ShutterWith energy savings in mind TX models are suppliedcomplete with an integral instantaneous automaticlouvre shutter concealed behind the interior cowl.Operates on intake and extract at any angleof mounting.When used with a T-Series controller, the shuttercan be set open with the fan motor switched Off toprovide natural ventilation without the security risk ofan open window.Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ElectricalSuitable for running at any angle. Quiet running,enclosed. Fitted with Standard Thermal OverloadProtection (S.T.O.P.).Supply voltage: 220-240V/1/50Hz.Suitable for operation in ambient temperatures from-40°C to +50°C.ModelsModel Stock RefGEN£ TradeTX6DR W161240 298.01TX7DR W162240 424.51TX9DR W163240 497.46TX12DR W164240 681.52Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 100 136 136 171B 196 206 229 308C 285 400 400 500D 220 258 302 378E 226 265 304 381F 19 19 19 19Fixing Hole Ø 184 222 260 337Weight kg 4.13 5.33 6.60 10.05PerformanceExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel low medium high (high) (med) @ 3m @ 240VTX6DR 200 (55) 240 (67) 265 (74) 30 43 0.24TX7DR 330 (92) 415 (115) 530 (147) 40 42 0.24TX9DR 455 (126) 630 (175) 725 (201) 85 45 0.42TX12DR 870 (242) 1040 (289) 1130 (314) 100 42 0.51136 T: 0844 856 0590


Commercial RangeTraditionalT-Series®In-Line ModelsFeatures & Benefits Extract/intake model in 3 sizes:6”, 9” and 12” Patented instantaneous electronic shuttersystem ensures quiet, trouble free operation For the best from your fan use the Ecotroniccontroller T-Series controllers and sensor saveenergy by only switching on the unitswhen you want them to, either manually orautomatically Easy fit connector Top Socket, standard onall modelsUK’s No. 1 Commercial FanNo other range of high performance in-line ductfan offers a combination of 3 impeller diameters,reversibility, low sound level, speed control andbuilt-in electric shutter. T-Series features a uniquespeed control pack which enables high, medium orlow speed to be preset to suit room size or requiredduty. Designed for use with rigid or flexible ducting,T-Series In-Line models can be plate mounted orfixed through partitions and in ceiling voids.T-Series controllers may be used with this model toobtain a choice of speeds, extract/intake airflowdirection and automatic sensor operation. The<strong>Vent</strong>-<strong>Axia</strong> Ecotronic controller gives even greaterrunning economy with its minimum speed settingand ‘E’ mode.Top SocketA connector Top Socket is now standard onall T-Series fans. Allowing fast and trouble-freemains connection.ShutterThe shutter is electronically controlled by an actuatorwith a damped action giving quiet operation duringinstant opening and closing. The interlockingedges of the shutter blades provide maximum backdraught protection.When the ventilating unit is used with a T-Seriescontroller, the shutter can be set open with the fanmotor switched off to provide natural ventilationwithout the security risk of an open window.ArrangementsWhere ducts pass through an unheated roof void,the duct should be insulated. Horizontal ductsshould fall away from the fan unit. In circumstanceswhere an excessive amount of moisture is present,a condensation trap should be installed in theexhaust duct. The fan unit should be accessible forregular maintenance.ElectricalSuitable for operation in ambient temperatures from-40°C to +50°C.Fitted with Standard Thermal Overload Protection(S.T.O.P.).Supply voltage 220-240V/1/50 Hz.ModelsGENModel Stock Ref £ TradeTX6IL W161710 273.13TX9IL W163710 498.35TX12IL W164710 663.08For use with rigid and flexible ducting. Can be platemountedor fixed to partitions and in ceiling voids.Dimensions (mm)Size Dim. 6 in 9 in 12 inA 75 71 200B 175 183 337C 45 41 45D 175 300 400E 220 302 378F 226 304 381Fixing Hole Ø 184 260 337Sizes 6 & 9Sizes 12PerformanceExtract performance m 3 /h (l/s) Watts Sound dB(A) AmpsModel low medium high (high) (med) @ 3m @ 240VTX6IL 318 (88) 398 (110) 444 (123) 30 45 0.24TX9IL 703 (195) 966 (268) 1050 (292) 85 47 0.42TX12IL 1674 (465) 2000 (556) 2230 (620) 100 51 0.51W: www.vent-axia.com 137


Commercial RangeSuper T-Series®Powerful Heavy DutyWall FansFeatures & Benefits 4 impeller diameters 355, 400, 450,500mm Complete with telescopic wall sleeve andshutter, ready for installation IP54 motor and terminal box Smart internal grille and external shutterwith flange trim Super quiet operation For the very best performance from yourfan, use the <strong>Vent</strong>-<strong>Axia</strong> 25 Amp electroniccontrollerPowerful <strong>Vent</strong>ilation<strong>Vent</strong>-<strong>Axia</strong>’s Super T-Series 355, 400, 450 and500mm fans provide efficient, quiet powerfulventilation with performances up to 4940m 3 /h.Tough heavy duty internal grilles and externalweather shutters ensure longevity, performance andpeace of mind.ConstructionThe axial fan at the heart of the Super T range isbased on an integrated impeller and internal rotormotor design which produces a very compact unit.A specially designed bellmouth inlet and mountingplate ensures an excellent performance to soundlevel ratio.ElectricalSingle phase 220-240V 50Hz. Capacitor start andrun. An IP54 terminal box is supplied with all modelswith conduit entry from the side of the wall liner. Allmotors are fitted with Standard Thermal OverloadProtection (S.T.O.P.), which should be wired viathe controller.ModelsSuper T - Gravity shutterGENWhen installed, only the room side aluminium fasciagrille is visible. The outside is finished with an externalgravity shutter and frame.Model Stock Ref £ TradeST355-16-WL 165510 759.64ST400-16-WL 166510 832.79ST450-16-WL 167510 974.37ST500-16-WL 168510 1093.16Super T TX - Electric shutterGENSuper T TX extract or intake models withpowerful, quiet, smooth-operation electric shutters.Model Stock Ref £ TradeSTX355 165710 978.63STX400 166710 1051.55STX450 167710 1193.68STX500 168710 1312.13Super T Filtered Air InputSuper T ARX and AR filtered air replacement inputunit. Consisting of a wall liner with high capacity highdisposable EU4 pleated filter which fits inside thewall liner.ARX ModelsGENWith electronically controlled integral shutter ARModels - external louvre fixed blade.Model Stock Ref £ TradeUnits with integral shutterSTARX355 165810 790.08STARX450 167810 905.75Units with louvre fixed bladesSTAR355 165910 349.09STAR450 167910 420.85Filtered Kitchen Extract - Super T GF GENSuper T GF extract unit without internal grille, butwith matching stainless steel filter housing and tray kitready for assembly on site and 50mm stainless steelframed mesh grease filter with handles.Model Stock Ref £ TradeSTGF355 165620 1042.41STGF400 166620 1143.56Replacement Grease FiltersGENSuper T replacement grease filters 50mm stainlesssteel mesh filter with handles. Supplied in packsof two.Model Stock Ref £ Trade355 452550 211.36400 452551 279.61Replacement Air FiltersSPHigh capacity EU4 pleated filter which fits inside wallliner. Supplied in packs of five.Model Stock Ref £ Trade355 452814 120.90450 452815 142.60Electronic 2.5A ControllerINDProvides variable motor speed control. On/Off withindication light. Infinitely variable speed slider control.Presettable minimum speed and sensor mode option:can be connected to a range of <strong>Vent</strong>-<strong>Axia</strong> sensors.Radio suppressed to BS 800. Includes electricshutter output.Stock Ref£ TradeW10303102M 80.87PerformanceModelExtractPerformancem 3 /h (l/s) F.I.D. WattsS.C.AmpsF.L.C.AmpsSounddB(A)@ 3m355-16 1735 (482) 94 1.25 0.5 40400-16 2165 (601) 110 1.4 0.56 45450-16 3550 (986) 225 2.58 1.15 48500-16 4940 (1372) 295 4.0 1.6 51355-14 2150 (597) 203 2.40 0.96 56400-14 3500 (972) 340 4.10 1.64 59Dimensions (mm)Impeller dia. 355 400 450 500A 550 597 657 727B 550 597 657 727C 470 520 580 650D 470 520 580 650Weight kg 17 22 28 33138 T: 0844 856 0590


Commercial RangeTraditionalStandard Range®Window ModelsFeatures & Benefits Extract / intake model in 4 sizes:6", 7", 9" and 12" IPX4 Rated Colour: White Manufactured in weather-resistantpolymeric materials For the best performance from your fan,use an Ecotronic controller Suitable for glass or panels up to 10mmthickClassic Retro-Style <strong>Vent</strong>ilationThis ever popular range of extract/intake ventilatingunits continues to satisfy the most demandingrequirements for efficient ventilation. The <strong>Vent</strong>-<strong>Axia</strong>Standard Range unit is supplied without a shutter.The shutter is available as an accessory, which canbe easily fitted within the unit.Standard Range Window fans are suitable for mostforms of single glazing or can be wall mounted ina <strong>Vent</strong>-<strong>Axia</strong> fixing plate. <strong>Vent</strong>-<strong>Axia</strong>’s patented spigotand ring method of fixing ensures easy installationand weather proof joint. The simple integratedcomponent design makes installation andservicing easy.PerformanceModelExtractPerformancem 3 /h (l/s) F.I.D.WattsMAX.SounddB(A) @3mAmps @240VS6WW 285 (79) 32 35 0.16S7WW 425 (118) 34 31 0.16S9WW 710 (197) 53 39 0.24S12WW 1560 (433) 84 42 0.36MotorPurpose designed enclosed motor. Suitable forrunning at any angle. Quiet running, enclosed.Supply voltage 220-240V/1/50 Hz. Suitable foroperation in ambient temperatures from -40° to+50°C. Fitted with Standard Thermal OverloadProtection (S.T.O.P.).Shutter Type SD/RThis extract/intake shutter fits inside the <strong>Vent</strong>-<strong>Axia</strong>unit and closes against unwanted back draughts.It can be fitted at the same time as the unit or at alater date if required.Airflow operated for extract use, cord operated lockfor intake use. For all models mounted in verticalsurfaces only.ControllerThe Ecotronic controller is recommended for usewith this model to provide full function control of thefan plus the option of sensor mode using a selectionof electro-mechanical switches to provide automaticswitching of the fan.Alternatively, single speed extract is achieved usinga normal On/Off switch.Easy CleaningIntegrated component design allows all partsto be dismantled for cleaning without the use ofspecialist tools.Protective GrillesWhere Standard Range units are installed in lowpositions, finger guards provide extra protection toVDE, DIN 31001.ModelsGENSize Stock Ref £TradeS6WW 131310 233.36S7WW 132310 304.37S9WW 133310 399.05S12WW 134310 560.96ShuttersSize Stock Ref £TradeS6SD/R 231710 57.69S7SD/R 232710 71.67S9SD/R 233710 92.51S12SD/R 234710 123.90Dimensions (mm)Size 6 in 7 in 9 in 12 inA 140 147 166 201B Ø 216 254 295 381C 21 21 21 21D 83 83 92 105E (max) 10 10 10 13Fixing hole Ø 184 222 260 337Weight kg 2.9 3.2 4.6 7.0W: www.vent-axia.com 139


Commercial RangeTraditionalStandard Range®Roof ModelsFeatures & Benefits Extract model in 4 sizes:6", 7", 9" and 12" IPX4 Rated Colour: White Wide range of sensors available Manufactured in weather-resistantpolymeric materials For the best performance from your fan,use an Ecotronic controllerClassic Retro-Styled <strong>Vent</strong>ilationA versatile and robust range of roof extractventilating units designed to satisfy the requirementsof efficient ventilation in commercial and industrialapplications. The simple, proven design of StandardRange makes installation and routine cleaning easy.Featuring a low profile cowl, the unit is ready forfitting into horizontal, angled and vertical glass,fixing plates on roofs and in vertical windows orwalls in exposed areas. With <strong>Vent</strong>-<strong>Axia</strong> roof plateassemblies, all four sizes can be fitted easily intoflat roofs. Suitable for roof installation plus windowand wall installation in exposed areas (eg: coastalpositions). <strong>Vent</strong>-<strong>Axia</strong>’s spigot and ring method offixing ensures easy installation and weather proofjoint. We recommend the use of sealing compoundunder the upper part of the unit when fitted in roofs.MotorPurpose designed enclosed motor. Suitable forrunning at any angle. Quiet running, continuousrated motor with sealed for life ball bearings.Suitable for operation in ambient temperatures from-40°C to +50°C. Fitted with Standard ThermalOverload Protection (S.T.O.P.).Supply voltage 220-240V/1/50Hz.All Standard Range roof models are designed tofit directly into horizontal and sloping windowsincluding wired cast, up to 10mm thick.In solid roofs, install using a roof plate assemblyand, if required, and eggcrate grille in the ceilingbelow. A suitable sealing compound shouldbe used between the glass/roof plate and theexterior seal.ModelsGENSize Stock Ref £ TradeS6RF 131410 264.84S7RF 132410 369.81S9RF 133410 463.95S12RF 134410 645.34Dimensions (mm)Size 6 in 7 in 9 in 12 inA 140 147 166 201B Ø 216 254 295 381C 21 21 21 21D 95 108 121 146E Ø 267 330 394 508Fixing hole Ø 184 222 260 337Weight kg 3.2 3.9 5.5 8.5PerformanceModelExtract Performancem 3 /h (l/s) F.I.D. Watts MAX. Sound dB(A) @ 3m Amps @ 240VS6RF 240 (67) 32 36 0.16S7RF 350 (97) 34 31 0.16S9RF 625 (174) 53 39 0.24S12RF 1130 (314) 84 42 0.36140 T: 0844 856 0590


Commercial RangeTraditionalStandard Range®Wall ModelsFeatures & Benefits Extract/intake models in 4 sizes:6", 7", 9" and 12" IPX4 Rated White fascia, wall sleeve and blackexternal weather louvre Optional shutter available Manufactured in weather-resistantpolymeric materials For the best performance from your fan,use an Ecotronic controllerClassic Retro-Styled <strong>Vent</strong>ilationThe proven Standard Range Wall models aredesigned to fit flush into most double brick wallsusing the rigid wall liner supplied with the unit.Provision is made within the liner for conduit entry.When installed, only the ivory fascia is visible onthe internal wall face. The external weather louvrefits flush to the outside. A shutter is available as anaccessory which can be easily fitted within the unit.On new building work the installation and wiringof the wall liner can be completed prior to the finalinstallation of the unit and controller. Fully shroudedconnectors on the fascia automatically connect thewiring to the motor when fitted to the wall liner.PerformanceMotorThe motor is purpose-designed. Suitable for runningat any angle. Quiet running, enclosed, sealed forlife ball bearings.Supply voltage: 220-240V/1/50Hz.Suitable for operation in ambient temperatures from-40°C to +50°C.Fitted with Standard Thermal Overload Protection(S.T.O.P.).ShutterType SD/RThis extract/intake shutter fits inside the <strong>Vent</strong>-<strong>Axia</strong>unit and closes against unwanted back draughts.It can be fitted at the same time as the unit or at alater date if required. Airflow operated for extractuse, cord operated lock for intake use.ControllerThe Ecotronic controller is recommended for usewith this model to give full function control of the fanincluding auto mode using an electro-mechanicalsensor from <strong>Vent</strong>-<strong>Axia</strong>’s sensor range. Alternatively,single speed extract is achieved using a normalOn/Off switch.ModelsGENSize Stock Ref £ TradeS6WL 131510 311.93S7WL 132510 423.04S9WL 133510 534.26S12WL 134510 700.99ShuttersSize Stock Ref £ TradeS6SD/R 231710 57.69S7SD/R 232710 71.67S9SD/R 233710 92.51S12SD/R 234710 123.90Dimensions (mm)Size 6 in 7 in 9 in 12 inA 279 279 279 279B 203 279 279 356C 279 362 362 448Fixing hole Ø 235 311 311 400Weight kg 4.1 5.7 6.7 10.1ModelExtract Performancem 3 /h (l/s) F.I.D. Watts MAX. Sound dB(A) @ 3m Amps @ 240VS6/WL 340 (94) 32 39 0.16S7/WL 544 (151) 34 35 0.16S9/WL 856 (238) 53 43 0.24S12/WL 1767 (491) 84 46 0.36W: www.vent-axia.com 141


Commercial RangeTraditionalStandard Range®Panel ModelsFeatures & Benefits Extract / intake model in 4 sizes:6", 7", 9" and 12" IPX4 Rated Built-in shutter available Colour: White Fascia Pre-wired lead for easy installation Manufactured in weather-resistantpolymeric materials For the best performance from your fan,use a Ecotronic controllerClassic Retro-Styled <strong>Vent</strong>ilationA versatile range of extract/intake ventilatingunits designed to satisfy the most demandingrequirements of efficient ventilation. Available in foursizes, the Standard Range units can be suppliedwithout a shutter for vertical installations. The shutteris available as an accessory which can be easilyfitted within the unit.Suitable for mounting at any angle, this range maybe installed in internal partitions, ceilings, ducts, and(with external louvres) through external walls.The outer spigot may be connected directly toflexible ducting and other <strong>Vent</strong>-<strong>Axia</strong> ventilationaccessories to suit individual applications. Wheninstalled, only the white fascia is visible.PerformanceShutterType SD/RThis vertical extract/intake shutter fits inside the<strong>Vent</strong>-<strong>Axia</strong> unit and closes against unwanted backdraughts. It can be fitted at the same time as the unitor at a later date if required.Airflow operated for extract use, cord operated forintake use.For all models mounted in vertical surfaces.MotorPurpose-designed enclosed ball bearing motor.Suitable for running at any angle. Quiet running.Supply voltage 220-240V/1/50 Hz.Suitable for operation in ambient temperatures from-40°C to +50°C.Fitted with Standard Thermal Overload Protection.(S.T.O.P.).ControllerThe Ecotronic Controller is recommended for usewith this model to provide full function control of thefan plus the option of sensor mode using a selectionof electro-mechanical switches to provide automaticswitching of the fan. Alternatively, single speedextract is achieved using a normal On/Off switch.ModelExtract Performancem 3 /h (l/s) F.I.D. Watts MAX. Sound dB(A) @ 3m Amps @ 240VS6/PL 354 (98) 32 41 0.16S7/PL 561 (156) 34 37 0.16S9/PL 927 (258) 53 45 0.24S12/PL 1910 (531) 84 48 0.36ModelGENSize Stock Ref £ TradeS6PL 131610 262.56S7PL 132610 332.26S9PL 133610 427.49S12PL 134610 587.35ShuttersGENSize Stock Ref £ TradeS6SD/R 231710 57.69S7SD/R 232710 71.67S9SD/R 233710 92.51S12SD/R 234710 123.90Dimensions (mm)Size 6 in 7 in 9 in 12 inA 127 137 156 197B 171 210 248 324C 219 250 302 387D 226 311 311 397E 254 337 337 419Fixing Hole Ø 254 337 337 419Weight kg 2.5 3.0 3.5 5.8142 T: 0844 856 0590


W: www.vent-axia.com 143


HygieneJet Dry ®The Jet Dry is one of the quickest hand dryerson the market. Using the latest twin jet styledrying technology giving just 10 secondsdry time.RangeDesigned to provide a cost effective alternativeto conventional hand dryers and paper towels.The fast dry range of hand dryers have beendeveloped with speed in mind. They providea rapid drying time from 10 seconds, thusreducing washroom time. They offer up to 70%energy saving when compared toconventional dryers.144 T: 0844 856 0590


W: www.vent-axia.com 145


Handryers10 Second Dry10 Second DryJet Dry®Automatic double sided high speed jet hand dryer. 10 second dry time Lo-Carbon DC Motor, 750W Air speed 95m/s Unique blue dry zone indicator Antibacterial coating Heater Element 900-1300W, adjustable Antibacterial dust filter 300 x 685 x 220mm (W x H x D) Weight 11kg IPX4 ratedGENStock Ref£ Trade447425 729.75Tempest®Automatic hand dryer for heavy duty applications. 10 second drying time Unique blue dry zone indicator Cover: Steel. Finish: porcelain enamel coating Insulation Earthed Class 1 201 x 277 x 175mm (W x H x D) Weight 6.6kg (packaged) Air flow 116m 3 /h Heater Element 450-900W, adjustable Infrared automatic operation 60 second auto shut off IPX1 ratedGENModels Stock Ref £ TradeSatin Stainless 439464 694.00Polished Stainless 439463 694.00SPModels Stock Ref £ TradeFilter Assembly Pack 444959 46.64Filter Replacement 444960 17.772 pack10 Second Dry 10 Second DryTempest®Automatic hand dryer for heavy duty applications. 10 second drying time. Unique blue dry zone indicator Cover: Steel. Finish: porcelain enamel coating Insulation Earthed Class 1 201 x 277 x 175mm (W x H x D) Weight 6.6kg (packaged) Air flow 116m3/h Heater Element 450-900W, adjustable Infrared automatic operation 60 second auto shut off IPX1 ratedGENStock Ref£ Trade437231 673.54Lo-Carbon eTempestAutomatic hand dryer for fast drying applications. 10 second drying time. Insulation Earthed Class 1 Cover: Steel 1.2 mm thick, epoxy coated Dimensions: 250 x 180 x 138.5mm (W x H x D) Weight: 3.8Kg Heater element 500 Watts Infrared Automatic Rated at 1K -1.2 kW at 230V Airflow 113m 3 /h 60 seconds auto shut off IPX1 ratedGENStock Ref£ Trade444956 550.15146 T: 0844 856 0590


HygieneUltradry® SXAutomatic ‘no-touch’, vandal resistant hand andface dryer for offices, shops, restaurants, pubs,clubs and hospitals. Fast drying feature. Cover: LM24 pressure die cast aluminium.Finish: epoxy/polyester powder coating. Motor: 5,500rpm, suppressed brushedmotor Insulation Earthed Class 1 264 x 275 x 177mm (H x W x D) Weight: 6.0kg (6.6kg packed) Sound level: 79 dB(A) at 1m Rated at: 2.4kW at 230V IP24 Rated BEAB ApprovedGENStock Ref£ Trade20101800SX 510.32Powerdry® SXPush button operated hand and face dryer forheavy duty applications in public lavatories,factories, railway stations and schools, etc. Fastdrying feature. Cover: LM24 pressure die cast aluminium.Finish: epoxy/polyester powder coating. Motor: 5,500rpm, suppressedbrushed motor. Insulation: Earthed, Class I 264 x 275 x 177mm (H x W x D) Weight: 6.0kg (6.6kg packed) Sound level: 79 dB(A) at 1m Rated at: 2.4kW at 230V IP24 Rated BEAB Approved Supply voltage:220-240V/1/50-60HzGENStock Ref£ Trade20101600SX 443.51Dryline +Automatic ‘no-touch’ operation compact handdryer. Suitable for smaller office washrooms,kitchens and clinics. Cover: ABS. Motor: 2450rpm shadedpole induction Double insulated appliance BEAB approved 280 x 275 x 143mm (H x W x D) Weight: 2.97kg (3.3kg packed) Sound level: 46 dB(A) at 3m Rated at: 1.7kW at 230V Supply voltage: 220-240V/1/50Hz IP21 RatedGENStock Ref£ Trade453915 164.66Ultradry® SX Stainless SteelAutomatic ‘no-touch’ hand dryer speciallydesigned for high performance hand drying infood preparation areas and hospital applicationsand eminently suitable for prestige installations.Fast drying feature. BEAB Approved. Cover: Satin polished stainless steel 264 x 275 x 177mm (H x W x D) Weight: 6.0kg (6.6kg packed) Sound level: 79 dB(A) at 1m Rated at: 2.4kW at 230V IP24 RatedGENStock Ref£Trade20101840SX 595.07Prepdry-Stainless SteelDesigned for food preparation areas andhospital applications where the highest levelsof hygiene have to be observed. Automatic‘no-touch’ hand dryer. BEAB Approved. Cover: Satin polished stainless steel Motor: External Rotor Brushless Motor2700 rpm Insulation Earthed Class 1 280 x 270 x 148mm (H x W x D) Weight: 4.0kg (4.5kg packed) Sound level: 65 dB(A) at 1m Rated at: 2.0 kW at 240V Supply voltage: 220-240V/1/50Hz. IP24 RatedGENStock Ref£Trade20101440 368.85Professional E®Automatic ‘no-touch’ hand dryer for smalleroffice washrooms, kitchens and clinics. Cover and base: high gloss, fire retardantABS/polycarbonate alloy Motor: 2700rpm external rotor, brushlessmotor Double insulated appliance 262 x 261 x 141mm (H x W x D) Weight: 3.09kg (3.52kg packed) Sound level: 65 dB(A) at 1m Rated at: 2.0 kW at 240V IP24 Rated BEAB Approved Supply voltage: 220-240V/1/50HzGENStock Ref£Trade20101402 241.65W: www.vent-axia.com 147


HandryersHygieneTurbodry® White AutoAutomatic hand & face dryer for heavy duty applications where arobust secure design is required. Cover: Steel. Finish porcelain enamel coating Insulation Earthed Class 1 248 x 284 x 202mm (H x W x D) Weight 7.5kg Sound level 70 dB(A) @1m Rated at 2.4kW @ 230 V IP23 RatedGENStock Ref£ Trade435427 541.93Turbodry® White ManualPush button hand & face dryer for heavy duty applications where arobust secure design is required. Cover: Steel. Finish: porcelain enamel coating Insulation Earthed Class 1 248 x 284 x 202mm (H x W x D) Weight 7.5kg Sound level 70 dB(A) @1m Rated at 2.4kW @ 230 V IP23 RatedGENStock Ref£ Trade435424 467.92Turbodry® Chrome AutoAutomatic hand & face dryer for heavy duty applications where arobust secure design is required. Cover: Steel. Chrome Insulation Earthed Class 1 248 x 284 x 202mm (H x W x D) Weight 7.5kg Sound level 70 dB(A) @1m Rated at 2.4kW @ 230 V IP23 RatedGENStock Ref£Trade435430 621.39Easy Dry RangeAn economical ABS or Metal covered automatic dryer, designedfor use in applications where good performance linked with pricesensitivity is of paramount importance. S/GS Approved. 2500 rpm induction motor Insulation Earthed Class 1 225 x 275 x 160mm (H x W x D) Weight: 3.3kg (3.65kg packed), 4.7kg (5.5kg packed) Sound levels: 54 dB(A) at 1m Rated: 1.0kW, 1.5kW or 2kW at 240V IP22 Rated Supply voltage: 220-240V/1/50HzModels Stock Ref £Trade1.0kW ABS 427935 GEN 90.301.5kW ABS 436297 BAS 103.771.5kW+Metal 431515 GEN 277.292.0kW+Metal 427936 BAS 293.26148 T: 0844 856 0590


Insect KillersHygienePortable Insect Killer High efficiency long life (50,000 hrs) LEDbulbs for attracting insects Power: 5.5W Coverage: 50m² ABS fire proof plastic as material or high safety Micro switch for high safety Extract fan for high efficiency Includes brush for cleaning and maintenance Approved to EN60335-2-59 CE/GS/ROHSGENStock Ref£Trade446877 25.20IK50 Power: 2x8W Coverage: 50m² Durable ABS fire proof plastic on side panels Large removable collection tray for easy cleaning High quality aluminium, easy to clean. Crack, fade, scratch andoil resistant Full protected outer mesh Energy efficient UV-A lamp Wall mountable, suspending or free standing Approved to EN60335-2-59 CE/GS/ROHS/REACH/PAH(TUV)GENStock Ref£Trade446878 26.25IK80 Power: 2x10W Coverage: 80m² Durable ABS fire proof plastic on side panels Large removable collection tray for easy cleaning High quality aluminium, crack, fade, scratch and oil resistant Full protected outer mesh Energy efficient UV-A lamp Wall mountable, suspending or free standing Approved to EN60335-2 59 CE/GS/ROHS/REACH/PAH(TUV)GENStock Ref£Trade446879 33.60IK150 Power: 2x20W Coverage: 150m² Durable ABS fire proof plastic on side panels Large removable collection tray for easy cleaning High quality aluminium, easy to clean. Crack, fade,scratch and oil resistant Full protected outer mesh Energy efficient UV-A lamp Wall mountable, suspending or free standing Approved to EN60335-2 59 CE/GS/ROHS/REACH/PAH(TUV)GENStock Ref£Trade446880 48.30Spare BulbsModel Stock Ref Size Weight Coverage Watts Stock Ref £TradePortable Insect Killer 446877 200 x 75 x 210mm 0.7kg 50m² 5.5 - -IK50 446878 340 x 100 x 260mm 1.83kg 50m² 2 x 8 446937 4.86IK80 446879 388 x 100 x 310mm 2.6kg 80m² 2 x 10 446938 5.39IK150 446880 646 x 100 x 360mm 3.60kg 150m² 2 x 20 446939 6.13SPW: www.vent-axia.com 149


CoolingMeteorCooling FanThe Meteor cooling fan from <strong>Vent</strong>-<strong>Axia</strong> islightweight for floor and wall mounting. Withthree speeds, five tilt positions and a timer itsperfect for any application.Range<strong>Vent</strong>-<strong>Axia</strong> CoolingThe right product atthe right time150 T: 0844 856 0590


W: www.vent-axia.com 151


CoolingJupiterDe-Stratification UnitFeatures & Benefits Available in two sizes Speed controllable High velocity fans Supplied with a grey coated finish - othercolours available to special order Available with built-in thermostatAir Movement FansThe <strong>Vent</strong>-<strong>Axia</strong> Jupiter range of de-stratification unitsis based on direct drive axial fans, housed in aneat and sturdy casing complete with eyeboltsfor suspension from chains or steel wires. Idealfor applications where the proposed mountingheight requires higher velocity fans or where openbladed ceiling fans are considered unsuitable.Jupiter fans can be used in stores, warehouses,factories, workshops, as well as many otherindustrial applications. The unit provides effectiveand positive air movement to improve the workingenvironment, particularly during summer months. Inaddition Jupiter fans can be used during the winterto re-circulate hot air from under ceilings and roofsdown to living and working areas.ElectricalSupply voltage 220-240V/1/50Hz. Direct driveaxials with speed controllable motors. The motorhub and impeller are statically and dynamicallybalanced for smooth operation and optimumperformance. Class F insulation, suitable foroperating in atmospheres of up to 95% RH andambient temperature of up to +60˚C.General InstallationFor cooling effect circulation of air is required inany given area. As a guide, mount Jupiter fans4.5-6m apart, in tropical climates 3m apart. Fansshould be mounted so that they do not interferewith lighting installations in any way. Mount fansaway from walls or pillars where possible to avoidobstruction of airflow.Heat SavingHeat savings are largely dependent on thedifference between the roof level and the workinglevel temperatures, the ventilation rate and thegeographical position.ModelsGENModel Stock Ref £ TradeNJUP315 457485 401.25NJUP315CTS 457486 581.81NJUP400 457487 484.09NJUP400CTS 457488 526.26AccessoriesSpeed ControllerGENStock Ref£ TradeRTRE20 164.12ThermoSwitchGENStock Ref£ Trade563502 30.08Suspension PackGENStock Ref£ Trade457490 55.94PerformanceDimensions (mm)Size A B C D Weight315 500 380 200 84 11 kg400 620 490 200 93 16 kgDCABAIRFLOWDuty Speed dBA 220/240V/50Hz/1PhMax MountingHeightModels CFM m 3 /s RPM @3m kW FLC SC Feet metresNJUP315/CTS 1290 0.610 1380 45 0.15 0.70 2.50 44 13.4NJUP400/CTS 3000 1.415 1320 51 0.35 1.60 5.50 72 22.0152 T: 0844 856 0590


Cooling<strong>Vent</strong>-<strong>Axia</strong>Hi-Line Plus®Ceiling Sweep FansFeatures & Benefits Suitable for winter De-stratificationapplications or summer cooling Three sweep diameters: 900mm, 1200mm,and 1400mm Two down rod lengths included Easy to install Quiet running Can be installed for either upward ordownward airflow Reversible electronic controller availableDe-stratification FansHi-Line Plus ceiling fans can be used in offices,stores, shops, foyers, schools, hospitals, kitchens,restaurants and many industrial applications such aswarehouses, factories, tanneries, and workshops.Hi-Line Plus fans will provide effective and positiveair movement to improve the working environmentparticularly during Summer months. In addition,Hi-Line Plus fans can be used during the Winter tore-circulate hot air from under ceilings and roofsdown to living and working areas thus helping toconserve energy.An infinitely variable speed controller is availablefor use with one or a combination of models up to5 units. Alternatively, Hi-Line Plus fans may be wireddirectly to a normal On/Off switch. For maximumbenefit, good ventilation is vital, we advise thatHi-Line Plus fans are used in conjunction with <strong>Vent</strong>-<strong>Axia</strong> T-Series or Standard Range ventilation units.Hi-Line Plus blades are produced from sheet steeland individually weighed to produce matched sets.PerformanceMotorThe motor is totally enclosed, capacitor start andrun. Suitable for temperatures up to +40°C.Supply Voltage 220-240V/1/50Hz.Fan SelectionFor energy conservation fan selection is dependentupon area and mounting height. Estimate theheight at which the fan can be mounted andthen calculate the relevant fan size from the tablebelow. Move to meet the diagonal line and thenread down to find out how much floor area per fanis suitable.Down RodsThe Hi-Line Plus fans include both a long and shortdown rod packaged as standard. The total droplength of the short down rod including motor is360mm. The total drop length of the long down rodincluding motor is 610mm.MOUNTING HEIGHT m131211109876543FLOOR AREA PER FAN ft 2500 1000 1500 2000 25001500 mmDIA.1400 mmDIA.1200 mmDIA.50 100 150 200FLOOR AREA PER FAN m 2ModelsGENModel Stock Ref £ TradeHL 90 428049 84.35HL 120 428050 84.35HL 140 428051 84.35Ceiling Fan ControllerSAC5 Reversible ControllerThe <strong>Vent</strong>-<strong>Axia</strong> ceiling fan controller adds extraflexibility to all Hi-Line Plus installations. Fan speedscan be selected to suit varying conditions. This is ofparticular benefit where mounting height is low. Thecontroller is designed to be used with a single fanor up to 5 Hi-Line fans.The controller is infinitely variable, has solid statecomponents, an insulated spindle, white coverplate and can be flush or surface mounted -please state when ordering. Suitable forcommercial environments.Hi-Line Plus fans should be used only with a<strong>Vent</strong>-<strong>Axia</strong> ceiling fan controller or anOn/Off switch.Supply Voltage 220-240V/1/50Hz. GENStock Ref£ Trade428238 56.34GENFor completely silent running we recommend theuse of a 5 step transformer. Suitable for up to 9ceiling sweep fans.Stock Ref£ Trade10314103 177.66Air displacement Max. AmpsModel Sweep dia. Colour m 3 /h watts @240VHL 90 900 mm White 8100 60 0.27HL 120 1200 mm White 12600 60 0.27HL 140 1400 mm White 15000 60 0.27Weight approximately 7kg.609DIA.569DIA.489DIA.444240383634323028262422201816141210250MOUNTING HEIGHT ftW: www.vent-axia.com 153


CoolingPortable AirConditionerFeatures & Benefits Environmentally friendly, R410A refrigerant Does not require specialist installation Built in 24 hour timer Effective cooling for homes and offices Double insulated cable with mouldedUK plugCompact CoolingPortable Air Conditioning units from <strong>Vent</strong>-<strong>Axia</strong>provide mobile comfort air-conditioning,de-humidifying or heating anywhere, anytime.Simply plug in and switch On. Perfect for domesticand light commercial use such as offices, shopsand reception areas where permanently installedair conditioning systems may be too inflexibleand expensive.ModelPOA3 in 1 Portable Air ConditionerThe 3 in 1 unit is a floor standing portableair conditioner, which is self contained.Does not require a separate outdoor unit orspecialist installation.3 in 1 - choose from cooling, dehumidifyingand fan only options16˚C-30˚C temperature setting24 hour timerMicro-processor controlR410A CFC free refrigerant12,000 btu/h coolingDouble insulated cable with mouldedUK plugStock Ref£ Trade448919 843.99SpecificationsModel 3 in 1Cooling capacity kW (btu/hr) 3.46 (12,000)Dehumidification - litres/hr 0.95Condensate disposalTank or HosePower Input - Watts 1340Power supply - via 13 Amp plug & socket230V, 1ph, 50HzDimensions - (HxWxD) mm 765 x 345 x 300Flexible hose length - mm/diameter - mm 1500/150RefrigerantR410A154 T: 0844 856 0590


<strong>Vent</strong>-<strong>Axia</strong> CoolingCoolingDesk FansPOAQuiet motor operation, 3 sizes 9” (230mm),12” (300mm) or 16” (406mm), 3 speed options(230mm has 2). Thermally fused motor, fixeddirection airflow or 87˚ arc of oscillation. Upwardor downward tilt, double insulated cable withmoulded UK plug. 9” and 12” models are wallmountable. Colour: white with dark grey blade.Size Stock Ref £ Trade9” 433546 22.3812” 433547 36.2916” 433548 39.88Tower FanPOAQuiet motor operation, 3 speed control switch.Space saving design, fixed position or 70˚ arcof oscillation. Adjustable On/Off 2 hour timer,double insulated cable with moulded UK plug.Stock Ref£ Trade435421 42.82MeteorPOALightweight, suitable for floor or wall mounting. 3speed, five tilt positions with fixed or 360° grillerotation and 2 hour timer. BEAB Approved. Colour:light grey. Moulded UK plug.Stock Ref£ Trade13101100 144.3816” Pedestal POAAdjustable height, quiet motor operation, 3 speedcontrol switch. Thermally fused motor, fixed positionor 87˚ arc of oscillation. Upward or downwardtilt, double insulated cable with moulded UK plug.Finish: white with dark grey blade.Stock Ref£ Trade433549 47.1912” Wall Fan POAQuiet motor operation, 3 speeds with oscillationand free neck. Ideal for wall fixing, 8 hour On/Off timer. Infra-red remote control sensor, doubleinsulated cable with moulded UK plug.Stock Ref£ Trade427583 57.86Box FanPOAQuiet motor operation, floor standing model, 3speed options. 360˚ louvre rotating air circulation,upward or downward tilt adjustment. Doubleinsulated cable with moulded UK plug.Stock Ref£ Trade427584 54.45W: www.vent-axia.com 155


HeatingThe simplicity of installing electric heating, particularly inhigh rise apartments means it is the natural choice whenrenovating properties.Traditional products with modern controls such as chargeand zone control provide energy savings for the occupierwithout compromising comfort in the home. Coupled withlow capital outlay for landlords, the <strong>Vent</strong>-<strong>Axia</strong> Heatingrange provides cost effective solutions for both parties.New from <strong>Vent</strong>-<strong>Axia</strong>With a slim, stylish design our new Opal Aluminium Radiatorrange offers households attractive, energy efficient comfort.Featuring an advanced digitally controlled thermostat, theOpal range gives you one of the most cost effective andenergy efficient electric heating systems available.RangeFeatures and BenefitsDigitally controlled thermostatDynamic fluid with high thermal inertiaThree user defined temperature settings forcomfort, economy and frost protectionSeven pre-set lifestyle heating schedules andone programmable optionSafety thermal regulatorSafe, clean and easy to operateAll radiators are powder coated externally inwhite (RAL 9016)No maintenance required156 T: 0844 856 0590


<strong>Vent</strong>-<strong>Axia</strong> heating is idealfor residential or commercialapplications. So whether it’sa bedroom or hallway, officeor shop, we can provide thesolution.W: www.vent-axia.com 157


Underfloor HeatingBLUETHERMAL TM MATThin Twin conductor heating matRenovating with heating matsMinimum floor thickness can be important inrenovation processes in order to avoid extra workon doors and thresholds. For these projects ourBluethermal TM Mat range is the ideal product. Theheating mat consists of a thin twin conductor heatingcable attached to an adhesive flexible glass fibre net.The thin heating cable has a total thickness of only4 mm, is delivered with a 2.5m cold lead and has awidth of 50 cm.The 100W/m² mat can be installed on any type oflevelled and stable sub floor, and can also be usedunder parquet or other wooden floor coverings. The150W/m² must be installed on a non-combustiblelevelled and stable sub floor. With all our productswe recommend the use of a thermostat with atemperature limiting function such as our Bluethermal TMThermostatic Controller.Construction: Solid resistance wires FEP insulation Solid copper earth wire Fibre-glass net PVC outer jacket Aluminium sheath Total thickness is 4mm Width 50cm (19.7”)Technical data:Area load 100 or 150 W/m² (9.3 or14.0 W/sq.ft.)Loads from 100 W to 1800 WMax. continuously operating temperature outerjacket: 65˚CTolerance on conductor resistance:-5 / + 10 %Rated voltage: 230VInstallation DetailPerformance Guide211234Tiles/floor coveringTile adhesiveThin screed/slabBluethermal TM Mat35456InsulationNon combustible sub floor6ElementStock Mat Area Output Mat Length Nom. UFHRef Model (m 2 ) (W) x Width (m) Resistance £Trade446175 VAUFHM 100 1.0 150 2 x 0.5 529.0 71.62446176 VAUFHM 100 1.5 150 3 x 0.5 352.7 83.86446177 VAUFHM 100 2.0 200 4 x 0.5 264.5 96.10446178 VAUFHM 100 2.5 250 5 x 0.5 211.6 108.35446179 VAUFHM 100 3.0 300 6 x 0.5 176.3 120.59446180 VAUFHM 100/HS 3.5 350 7 x 0.5 151.1 132.83446181 VAUFHM 100/HS 4.0 400 8 x 0.5 132.3 145.08446182 VAUFHM 100/HS 5.0 500 10 x 0.5 105.8 169.56446183 VAUFHM 100/HS 6.0 600 12 x 0.5 88.2 194.06446184 VAUFHM 100/HS 7.0 700 14 x 0.5 75.6 218.55446185 VAUFHM 100/HS 8.0 800 16 x 0.5 66.1 243.04446186 VAUFHM 100/HS 10.0 1500 20 x 0.5 52.9 292.01446187 VAUFHM 100/HS 12.0 1200 24 x 0.5 44.1 340.99446188 VAUFHM 150 1.0 150 2 x 0.5 352.7 79.57446189 VAUFHM 150 1.5 225 3 x 0.5 235.1 93.18446190 VAUFHM 150 2.0 300 4 x 0.5 176.3 106.78446191 VAUFHM 150/HS 2.5 375 5 x 0.5 141.1 120.39446192 VAUFHM 150/HS 3.0 450 6 x 0.5 117.6 133.99446193 VAUFHM 150/HS 3.5 525 7 x 0.5 100.8 147.60446194 VAUFHM 150/HS 4.0 600 8 x 0.5 88,2 161.20446195 VAUFHM 150/HS 5.0 750 10 x 0.5 70.5 188.41446196 VAUFHM 150/HS 6.0 900 12 x 0.5 58.8 215.62446197 VAUFHM 150/HS 7.0 1050 14 x 0.5 50.4 242.83446198 VAUFHM 150/HS 8.0 1200 16 x 0.5 44.1 270.04446199 VAUFHM 150/HS 10.0 1500 20 x 0.5 35.3 324.46446200 VAUFHM 150/HS 12.0 1800 24 x 0.5 29.4 378.88*HS = hidden splice.The products are delivered with a 2.5m cold lead158 T: 0844 856 0590


Heating RangeBLUETHERMAL TM CABLETwin conductor cablefor direct heatingInstallation Detail12Ceramic tilesTile adhesiveRenovation with heating cablesWhen renovating with our Bluethermal TM Cablerange, apply the cable to a non-combustible subfloor(minimum thickness 5mm) and take into considerationthe placement of permanent installations such asshowers, baths, toilets, cupboards etc. Place theend seal away from potentially wet areas of thefloor. See picture illustrating the placement of afree laid heating cable. Note that the cable is notcrossing or touching itself, this is to provide the bestpossible heat conductivity to the surroundings ofthe cable.The heating cable is embedded in a screed/concrete with low overall construction height.After drying and hardening, the moisturebarrier/membrane can be put on top of the screed/concrete before the floor covering is installed.Construction: Performance Guide654231345640-60mm screedBluethermal TM CableMin 10mm solid subfloor. Waterresistant if room is a wetroomLower floor over well insulatedwooden beamsStockLoad @230V Element lengthNomelementresistanceOuterdiameter UFHRef Model (W) (m) (ft) (Ω) (mm) £Trade446201 VAUFHC 300 17.6 58 176.30 7.0 82.97446202 VAUFHC 400 23.5 77 132.30 7.0 90.51446203 VAUFHC 500 29.3 96 105.80 7.0 95.26446204 VAUFHC 600 35.2 115 88.20 7.0 105.54446205 VAUFHC 700 41.0 135 75.60 7.0 110.32446206 VAUFHC 840 49.7 162 63.00 7.0 123.80446207 VAUFHC 1000 58.3 191 52.90 7.0 144.88446208 VAUFHC 1250 72.4 237 42.30 7.0 161.68446209 VAUFHC 1370 80.8 265 38.60 7.0 179.97446210 VAUFHC 1700 150.0 328 31.10 7.0 196.56446211 VAUFHC 2100 123.7 405 25.20 7.0 234.12446212 VAUFHC 2600 154.5 507 20.30 7.0 260.76446213 VAUFHC 3300 194.0 615 16.00 7.0 341.44Technical data:3300Wjacket: 65°C (149°F)- 5 / + 10 %Installation Example156412233 45Cable laid behind the toilet to dry upcondensationEnd seal preferably placed in a dry zone ofthe floorPut some distance between drain and cableto avoid excessive dryness of gully andodour problemsDrain/gullyFloor sensor6Transition between heating cable and coldend attachmentW: www.vent-axia.com 159


AccessoriesBluethermal tm Thermostatic ControllerApplicationsPrecise and accurate temperature control isimportant to fully achieve the advantages of underfloor heating without using more electric energythan necessary. Heating cables in combination withan accurate thermostat are one of the most energyefficient heating systems one can have in a modernbuilding.The design of the thermostat is unique. Every detailhas been carefully designed, paying specialattention to aesthetic appearance, user-friendlinessand quality, as required and demanded by bothconsumers and professional installers.Features Large screen with blue backlighting 4-event programme or constant temperaturecontrol Clock: 12 hours (am/pm) / 24 hours Day display: Monday - Sunday Celsius or Fahrenheit display selection Frost protection 5 to 40˚C working range (default)SpecificationsAccuracy: +0.5˚C / 1˚FMaximum load: 16APower supply: 230VDimensions: 86 x 86 13mm (WxHxD)IP21 RatedUFHModel Stock Ref £TradeVAUFHTC 446174 74.90Recommended Application Guide<strong>Product</strong>Application Output Max Normal VAUFHM 100 VAUFHM 150 VAUFHCEntrance/Hall 150 80-150 Entrance/Porch 150 120-150 Hall/Corridor 150 80-100 Living Room 100 70-100 Kitchen 100 70-100 W/C 150 120-150 Utility Room 150 120-150 Bedroom 100 70-100 Bathroom 150 120-150 Office 100 80-100 Storage Room 100 80-100 Shop 100 80-100 Workshop 100 80-100 Splicing KitIn the unlikely event that you need to repair ourheating cables, this kit provides you with thenecessary joints to get your systems back running.UFHModel Stock Ref £TradeVAUFHS 446214 30.57160 T: 0844 856 0590


Heating RangeInsulation BoardsApplicationsOur insulation boards limit the downward heat losswithin the system directing the heat to where youneed it.<strong>Vent</strong>-<strong>Axia</strong> underfloor heating insulation boards arerecommended for use with our products to increasethe efficiency and warm up time of the system, savingboth energy and money. They are available from6mm to 70mm thick sold, in packs as detailed in thetable.The 6, 10 and 20mm products are held in stock withthe other products available on request.Fixing to Wooden FloorsBy Adhesive - The boards can be laid onto a levelfloor, with a suitable flexible rapid set cementitious tileadhesive – solvent based or ready mixed adhesivesMUST NOT be used.By Mechanical Fixing - The boards (other than 6mmboards) can be installed with mechanical fixings onlyto flat and level timber floors using approximately12 fixings per 1200mm x 600mm board, withsuitable screws and a 35mm fixing washer underthe head. Fixing kits are available as detailed in thetable below.Fixing to Concrete FloorsA suitable flexible rapid set cementitious tile adhesiveshould be used – solvent based adhesives or readymixed adhesives MUST NOT be used.<strong>Vent</strong>-<strong>Axia</strong> underfloor heating insulation boardsStock Ref ModelThicknessmmNumber ofboards perboxPackcoverage m 2U-Valuew/m 2 /kUFH£Trade447267 VAUFHIB6 6 8 5.76 4.5 134.37447268 VAUFHIB10 10 6 4.32 2.7 100.77447269 VAUFHIB12 12.5 6 4.32 2.16 118.67447270 VAUFHIB20 20 6 4.32 1.35 128.99447271 VAUFHIB30 30 4 2.88 0.9 100.77447272 VAUFHIB40 40 3 2.16 0.67 89.00447273 VAUFHIB50 50 2 1.44 0.54 66.47447274 VAUFHIB60 60 2 1.44 0.45 74.90447275 VAUFHIB70 70 2 1.44 0.39 91.43<strong>Vent</strong>-<strong>Axia</strong> underfloor heating insulation boards accessoriesStockRef Model TypeTo be used withInsulation boardSizeUFH£Trade447277 VAUFHIB10S Screws (50 per pack) VAUFHIB6 -12 25mm (L) 12.86447278 VAUFHIB20S Screws (50 per pack) VAUFHIB20 35mm (L) 13.69447279 VAUFHIB30S Screws (50 per pack) VAUFHIB30 45mm (L) 15.14447280 VAUFHIB40S Screws (50 per pack) VAUFHIB40 60mm (L) 16.25447281 VAUFHIB50S Screws (50 per pack) VAUFHIB50 65mm (L) 16.25447282 VAUFHIB60S Screws (50 per pack) VAUFHIB60 75mm (L) 20.24447283 VAUFHIBW Washers (50 per pack) All 35mmØ 17.72447276 VAUFHIBT Tape All 100mm (W) x 50m roll (L) 16.09W: www.vent-axia.com 161


NEW RANGEHeated Towel RailsFeatures & Benefits IP55 rated Wall fixings included Plug and vent included Five year leakage warranty One Year Manufacturer’s Guarantee Heating element included Stylish designs One year surface and element warranty Steel construction with high quality whiteand chrome finishes <strong>Product</strong>ion is carried out using latesttechnology Absolute consistency in quality Complete fitting set supplied Pressure tested to 13 bar Comprehensive step by step fittinginstructions<strong>Vent</strong>-<strong>Axia</strong> Heated Towel Rails quickly warm and drytowels. Their presence on the wall also adds to theoverall style, temperature and comfort of the room.This comprehensive range of white and chrometowel rails offers ten different models across the flat,curved and designer ranges. The range offers sizesfrom 500 x 600mm to 500 x 1500mm availablein four heat outputs of 100, 150, 250 and 400Wmatched to the size of the rail.The range is complemented by an advancedcontroller available in white and chrome giving youcontrol of five heat outputs. The controller also offersan eco mode ideal for use when drying your towelsto ensure minimal energy use. This feature turns onthe rail on full power for 30 minutes then reducesthe output to the user setting for a further 90 minutesbefore turning the towel rail off.Controller IPX4 rated White or chrome finish Five power settings Eco timed function Two year warrantyStock Ref. Model Description FinishDimensions(W x H) / mm Output / WGEN£TradeTowel Rails447854 VATRS100C ‘S’ Shape Chrome 600 x 500 100 102.03447855 VATRF150CChrome 400 x 700 150 136.15447856 VATRF250W White 500 x 1100 250 127.92Flat447857 VATRF250C Chrome 500 x 1100 250 176.17447858 VATRF400C Chrome 500 x 1500 400 250.31447859 VATRC250CChrome 500 x 1100 250 183.55Curved447860 VATRC400C Chrome 500 x 1500 400 260.40447861 Atacama LSChrome 400 x 700 150 208.46447862 Atacama OS DesignerChrome 300 x 650 150 214.38447863 Atacama SS Chrome 500 x 1000 250 215.25Accessories447864 VATRCWWhite single gang n/a 53.77Controller447865 VATRCC Chrome single gang n/a 72.80447866 VATRDFK150 Replacementn/a n/a 150 50.14447867 VATRDFK250 element / dual n/a n/a 250 52.15447868 VATRDFK400 fuel kitn/a n/a 400 54.11162 T: 0844 856 0590


Heating RangeHeated Towel Rail RangeS-shaped chrome towel railVATRS100CStock Ref447854Flat chrome towel railVATRF150CStock Ref447855Flat white towel railVATRF250WStock Ref447856Flat chrome towel railVATRF250CStock Ref447857Flat chrome towel railVATRF400CStock Ref447858Curved chrome towel railVATRC250CStock Ref447859Curved chrome towel railVATRC400CStock Ref447860Flat designer towel railAtacama LSStock Ref447861Oval ldesigner towel railAtacama OSStock Ref447862Flat designer towel railAtacama SSStock Ref447863W: www.vent-axia.com 163


NEW RANGERadiant HeatersFeatures and Benefits Economical and easy to install Silent in operation No yearly maintenance cost Shortwave IR halogen lamp One second heat up time Precision heating directed where youneed it Up to 5000 hours element life span IP65 rated (VARO model)ProfileOur radiant heating product range gives theflexibility to deal with large and small unheatedspaces which would be uneconomical to heat usingtraditional space heating.Area such as bars, restaurants, terraces, deliveryareas, warehouses and churches, are someexamples where our new radiant heating productswill provide an economical heating solution.Radiant heat and its advantagesThe heat we feel from the sun is called Radiant heatand is part of the electromagnetic spectrum calledinfrared. Ultra violet and visible light also belong tothe same family.Visible light is the easiest part of this spectrum tounderstand, light travels in a straight line from thesource is unaffected by air and is invisible until ithits a surface. Shadows are a good example of thisand are the absence of light.Infrared rays behave in the same way, we cannotsee them but we can feel them as warmth. A goodexample of this is the effect created when you movefrom the shade into the sun, although the temperatureis the same the perceived temperature when indirect sunlight is much higher, This phenomenonmakes sunbathing possible during winter holidays.There are three categories of Infrared, short wave(IR A), medium wave (IR B) and long wave (IR C),the shorter the wave length the easier it travelsthrough the air.The advantage when using short wave Infraredheating are that the rays cut through the air andare not effected by air movement and only transmitsits energy when it collides with a solid object.The rays also travel in a straight line so can bedirected where you need it, ideal in locations whichfeature high ceilings, have high air change rates orare outside.Convection Heating and Radiant Heating Comparison21ºCAirTemperature18ºCPerceivedTemperature15ºCSurfaceTemperatureWave spectrumHigh energy photonsLow energy photonsFrequency, v (Hz)1024 1022 1020 1018 1018 1014 1012 1010 108 106 104 102 10Gamma rays X-rays UV IR Microwaves Radio WavesFM & AMLong radio waves10-16 10-14 10-12 10-10 10-8 10-6 10-4 10-2 10 102 104 106 108Wavelength, (m)UV: Ultraviolett Radiation VIS:Visible Radiation; Light IR: Infrared RadiationUV-C100-280nmUV-B280-315nmUV-A315-400nmWave Infrared comparisonHeatingwithConvection15ºCAirTemperature18ºCPerceivedTemperature21ºCSurfaceTemperatureVioletBlueBlue/GreenGreenYellow/GreenYellowOrangeRedUV-A800-1400nmUV-B1400nm- 3,0μmHeating withthe RaditantEffectUV-C3,0μm - 1mmShort Wave Infrared Medium Wave Infrared Long Wave InfraredTypical Source IR Halogen Lamp Quartz Heat Source ResistanceMaterialsTungsten Filament weldedin a quartz tubeFilament in compound ofFe-Cr-Al in a quartz tubeFilament in compound ofFe-Cr-Al in a steel tubeRadiant efficiency 92% 60% 40%Switch on/off times 1 second 30 second 5 minutes164 T: 0844 856 0590


Heating RangeDimensions (mm)313486235Front Side Top313496376Front Side Top313496515Front Side Top836112FrontSide83Technical DetailsStock Ref Model Weight Voltage rating BulbLuminousspectrum Accessories Power AmpsHeatingrangeReplacementElementsGEN£Trade447602 VARI 2000 2.2kg 220-240V - 50-60Hz gold x1 IR-A wall bracket 2000W 9 9-12m 2 VARI 447605 193.39447603 VARI 4000 3.0kg 220-240V - 50-60Hz gold x1 IR-A wall bracket 4000W 18 12-16m 2 VARI 447605 282.24447604 VARI 6000 3.8 kg 380-415V - 50-60Hz gold x1 IR-A wall bracket 6000W 27 16-20m 2 VARI 447605 369.14447600 VAR0 1800 1.0 kg 230V ~ 50-60Hz gold x1 IR-A wall bracket 1800W 8 8-10 m 2 VARO 447606 120.70TopW: www.vent-axia.com 165


Heating RangeNEW RANGEOpalAluminium RadiatorsFeatures & Benefits Aluminium block with innovative curvedelements Digitally controlled thermostat Dynamic fluid with high thermal inertia Temperature setting: Comfort, Economy,Anti-Freeze Seven pre-set lifestyle heating schedulesand one programmable option Outputs from 500W - 1500W Safety thermal regulator Ease of installation Safe, clean and easy to operate All radiators are powder coated externallyin white (RAL 9016) No maintenance required These slim line radiators are 96mm deep All radiators are supplied with wall fixingbrackets Each radiator is supplied with 1.6m lengthcable UK power cableThe <strong>Vent</strong>-<strong>Axia</strong> Opal range of Aluminium Radiatorsoffers a slim stylish design with advanced digitalthermostatic control giving you one of the mostcost effective and energy efficient electric heatingsystem you can have.Popular with specifiers, contractors and homeowners, the Opal range is ideal for new buildand refurbishment.Available in five sizes, our range provides asolution for any size room with outputs from500W - 1500W.All of the Opal Aluminium Radiators controllers arefully programmable offering closer management ofenergy control with resultant costs savings. This canbe measured with the on board energy monitorallowing you to see how much energy you areusing to heat your room.All units come as standard with all the features and Seven pre-set lifestyle l heating schedulescontrols you would expect to see on an advanced The heater is programmed with 7 plans duringheating system.its manufacture which can be adapted to mostheating situations. The 7 plans are described in thetable below.Energy saving electronic controlAccurate, fast acting control is essential forreducing temperature overrun and minimisingenergy consumption.The silent operating electronic thermostat isaccurate to +/- 0.3˚ and acts quickly to maintainconsistent temperature levels.RoomTemperature ºC232119SpecificationMechanical thermostatElectronic thermostatEnergy savedComfortTimeThe nF Plan is programmed for when you are awayfrom your home for a long period of time andwould like to protect it against freezing. The greeneconomy LED will flash.The UE PLan is a heating schedule designed forweekends. With this plan the heater will work fromMonday to Thursday in the antifreeze position. Inthe period from Friday to Sunday you can configurea programme according to your needs.PLO1PLO2PLO3PLO4PLnFPLUEPLCFWorking Days/hrsWeekend/hrs0 6 12 18 24 0 6 12 18 24Comfort Economy AntifreezeWeight Dimensions (mm) Output GENStock Ref Model kg H W D W Amps £ Trade448469 VAAR500 500W 11 584 460 96 500 2.3 274.14448470 VAAR750 750W 15 584 620 96 750 3.4 315.34448471 VAAR1000 1000W 19 584 780 96 1000 4.5 366.63448472 VAAR1250 1250W 23 584 940 96 1250 5.7 418.82448473 VAAR1500 1500W 27 584 1100 96 1500 6.8 474.24166 T: 0844 856 0590


Heating RangeOptimax Plus®Panel HeaterFeatures & Benefits Integral adjustable thermostat Optional integral timer Frost protection setting of 5˚C BEAB approved Unique quick fix wall bracket Colour RAL 9001 Ideal compliment to Storage heaters Brackets for panel includedComfort Heating<strong>Vent</strong>-<strong>Axia</strong>’s Standard Panel Heaters are perfectfor smaller rooms such as bedrooms, studies,conservatories and loft conversions.ModelsThermostat ModelAll <strong>Vent</strong>-<strong>Axia</strong> Panel Heaters have a built-inadjustable thermostat offering a full temperaturerange, including a frost protection setting of 5˚C.For maximum safety there is a thermal cut-out on allmodels to prevent overheating, should the outletgrille be accidentally covered.Dimensions (mm)Panel HeatersManual and Timer versions available.GENModel Stock Ref £ TradeVAPH 075 439034 84.66VAPH 075T 439038 109.20VAPH 125 439035 94.83VAPH 125T 439039 119.35VAPH 150 439036 103.27VAPH 150T 439040 128.68VAPH 200 439037 107.51VAPH 200T 439041 134.58<strong>Vent</strong>-<strong>Axia</strong>’s Panel Heaters offer a wide rangeof heat outputs from 750W to 2000W andevery model is available with or without a timer.<strong>Vent</strong>-<strong>Axia</strong> Panel Heaters look as good as theyperform. Stylish and slim, they occupy minimal wallspace and are finished in an attractive white finish.<strong>Vent</strong>-<strong>Axia</strong> Panel Heaters are wall mounted andconnected to the permanent electrical supply via afused connection switched outlet. <strong>Vent</strong>-<strong>Axia</strong> PanelHeaters are supplied with mounting brackets andone metre of cable connected to the bottom righthand side of the unit.SpecificationOutput A Width B Depth X Bracket WeightStock Ref Model kW mm mm mm kg439034 / 439038 VAPH 075/T 0.75 620 108 288 6.2439035 / 439039 VAPH 125/T 1.25 690 108 358 6.6439036 / 439040 VAPH 150/T 1.5 690 108 358 6.6439037 / 439041 VAPH 200/T 2 860 108 528 8.0220-240V-50Hz. BEAB Approved.W: www.vent-axia.com 167


Heating RangeOptimax Plus®CombinationStorage HeaterFeatures & Benefits Optimised charge period offers 15%energy saving Reduced installation times Conveniently mounted controls Range of 3 heat outputs Colour RAL 9001 IP20 ratedComfort Heating<strong>Vent</strong>-<strong>Axia</strong> Combination Storage Heaters takeadvantage of low tariff night-time electricity in thesame way as our domestic storage heaters.Features such as snap-on feet, simple wall fixingsand quick assembly mean that new installations orreplacement of existing units are completed withminimum disruption. The cable entry is at the backof the unit on the bottom right hand side.Automatic models incorporate an ambientthermostat which optimises the charge to suit roomconditions, typically saving an additional 15% inenergy costs.<strong>Vent</strong>-<strong>Axia</strong> Combination Heaters are slim, compactand aesthetically pleasing. Their attractive neutralfinish blends in with a variety of decors.Dimensions (mm)150min.Width150min.730 Height<strong>Vent</strong>-<strong>Axia</strong> Combination Heaters combine thebenefit of a domestic storage heater and aconvector heater in one casing. The storage heateroffers comfortable heat around the clock takingadvantage of low tariff electricity.The controls are conveniently positioned on topof the heater for ease of use. Once the optimumsettings are selected, no further adjustment isnecessary. A separate convector heater On/Offswitch is situated on the side of the casing togetherwith a thermostat for temperature control.The convector heater can be switched on atany time to offer additional heat when required,or used outside the normal heating season forinstant heating.Combination Heaters require a permanent powersupply for immediate convection heating whenrequired. The storage heater section has a separateoff-peak supply.ModelsCombination HeatersGENModel Stock Ref £ TradeVACSH 12A 438919 445.40VACSH 18A 438920 522.46VACSH 24A 438921 628.53(A = Automatic)250min.300min.SpecificationInput Width Height Depth Weight NumberStock Ref Model kW mm mm mm kg of Bricks438919 VACSH 12A 1.70 540 730 185 79 8438920 VACSH 18A 2.55 765 730 185 116 12438921 VACSH 24A 3.40 990 730 185 152 16220-240V-50Hz. BEAB Approved.168 T: 0844 856 0590


Heating RangeOptimax Plus®Storage HeaterFeatures & Benefits Perfect for offices and homes Optimised charge period offers 15%energy saving Reduced installation times Conveniently mounted controls Range of 4 heat outputs Colour RAL 9001 IP20 ratedComfort Heating<strong>Vent</strong>-<strong>Axia</strong> Storage Heaters are often an economicalternative for new build or in existing properties,particularly where no other fuel source is available.<strong>Vent</strong>-<strong>Axia</strong> Storage Heaters are simple to install,economical to run and virtually maintenance free.Ideal for use in living rooms, hallways and landings.The range can be installed in bathrooms outsideZone 2, provided that the installation complies withIEE regulations.<strong>Vent</strong>-<strong>Axia</strong> Storage Heaters offer comfortablewarmth around the clock taking advantage oflow-tariff electricity.Ease of InstallationSimple to install wall fixings and quick assemblymean that new installations or replacementof existing units are completed with minimumdisruption. The cable entry is at the back of the uniton the bottom right hand side.Manual models charge throughout the low-tariffperiod. Automatic models incorporate an ambientthermostat which optimises the charge to suit roomconditions, typically saving an additional 15% inenergy costs.<strong>Vent</strong>-<strong>Axia</strong> Storage Heaters are slim, compact andaesthetically pleasing. Their attractive neutral finishblends in with furnishings.The controls are conveniently positioned on topof the storage heater for ease of use. Once theoptimum settings are selected, no further adjustmentis necessary.Then just sit back and enjoy comforting warmth dayafter day.ModelsStorage HeatersManual and Automatic versions available.GENModel Stock Ref £ TradeVASH 6 439355 199.90VASH 12 439356 306.02VASH 12A 439359 338.27VASH 18 439357 391.30VASH 18A 439360 426.37VASH 24 439358 476.57VASH 24A 439361 519.24A=AutomaticDimensions (mm)SpecificationInput Width Height Depth Weight NumberStock Ref Model kW mm mm mm kg of Bricks439355 VASH 6 0.85 332 700 170 41 4439356 / 439359 VASH 12/12A 1.70 560 700 170 77 8439357 / 439360 VASH18/18A 2.55 788 700 170 110 12439358 / 439361 VASH 24/24A 3.40 1016 700 170 145 16220-240V-50Hz. BEAB Approved.W: www.vent-axia.com 169


Heating RangeHeating RangePlinth HeatersFeatures & Benefits Ideal for where wall space is at apremium Fits neatly into plinths Finishes: W-White, B-Brown &S - Stainless Steel Optional thermostatic control 5-30˚C Can be used with remote switchVARSU 436494 Two heat settings 1kW & 2kW<strong>Vent</strong>-<strong>Axia</strong> Plinth Heaters are designed for use inkitchens and bedrooms. They fit neatly into mosttypes of fitted furniture, fascias, display units andfalse walls.When installed in a corner with an adjacentcupboard to the right, a distance of at least150mm must be maintained between the righthand end of the heater and the front of the adjacentcupboard door.<strong>Vent</strong>-<strong>Axia</strong> Plinth Heaters are supplied with 1.5mof 1.5mm2 3 core cable, terminating on the righthand side of the unit.ModelsStandard ModelsGENModel Stock Ref £ TradeVAPL2-S 459112 93.08VAPL2-W 459113 93.08VAPL2-B 459114 93.08Thermostatic ModelsGENModel Stock Ref £ TradeVAPL2TC-S 459115 99.12VAPL2TC-W 459116 99.12VAPL2TC-B 459117 99.12Dimensions (mm)380 420260Cutout dimensions (mm) (W x H) 390 x 105Weight 3kg110Warm Air CurtainsFeatures & Benefits Integral Switching for faster installation Three heat settings and fan only mode Models to suit single and doubledoorways Suitable for use as a high level fan heater<strong>Vent</strong>-<strong>Axia</strong> Warmair Curtains provide a heateddownflow of warm air in doorways of commercialpremises such as shops, offices and schools.The robust outer case is made from painted steelwith an off white epoxy finish. Accommodatingvarying door widths is easily achieved by installingWarmair units ‘Side by Side’.<strong>Vent</strong>-<strong>Axia</strong> Warmair Curtains are supplied with0.75m of 3 core cable, and mounting brackets.Three Warmair models are available offering heatoutputs & fan only :Warmair 3 - 3 kW, 2 kW, 1 kWWarmair 4.5 - 4.5 kW, 3 kW, 1.5 kWWarmair 6 - 6kW,4 kW, 2 kWModelsWarmair Curtain HeatersManual and Automatic versions available. GENModel Stock Ref £ TradeWarmair 3 456343 189.93Warmair 4.5 456344 217.10Warmair 6 456345 345.39Remote SwitchGENRemote Switch unit to control warm air units. Switchallows for fan only & 3 heat settings.Model Stock Ref £ TradeVARSU 436494 46.87SpecificationRating Width Height DepthModel kW mm mm mmWarmair 3 3.0 650 103 210Warmair 4.5 4.5 650 103 210Warmair 6 6.0 900 103 210220-240V-50Hz. BEAB Approved.Downflow HeaterFeatures & Benefits Stylish compact design 2kW Output Pull Cord operation Indication Light Double Insulated Class II IPX2 ratedThe <strong>Vent</strong>-<strong>Axia</strong> Downflow Heater will deliver awelcoming warmth when its most needed inall room applications including bathrooms andliving spaces. pull cord and is suitable for use within zone 2 ofthe bathroom. The Downflow Heater has a 2kWpower loading and is designed to be permanentlywall mounted for use with an AC electrical supply.The Downflow Heater is fitted with a pre-setstep down thermostat which regulates the roomtemperature and offers an energy saving. Formaximum safety the heater includes a thermalcut-out feature to prevent overheating. With aindication light the Downflow Heater is simpleto install.ModelDownflow HeaterGENModel Stock Ref £ TradeVADH2 455834 53.08SpecificationRating W H D WeightModel kW mm mm mm kgVADH 2 2 229 242 109 1220-240V-50Hz.170 T: 0844 856 0590


Portable HeatingHeating RangeConvector HeaterFeatures & Benefits Silent operation Ideal for use where occasionalheating is required 3 heat outputs Thermostatic control Safety thermal cutout BEAB ApprovalThe <strong>Vent</strong>-<strong>Axia</strong> Convector Heater is ideal for usein any domestic or commercial room where extraor occasional heating is required. The heater issuitable for use in the home, offices, shops andworkshops, but is not recommended for use inbathrooms.The unit offers three heat outputs; 0.75kW, 1.25kWand 2kW, and is supplied with a thermostaticcontrol.Portable Fan HeaterFeatures & Benefits Thermostat control Fan only mode for summer cooling 2 heat settings Safety cutoutThe <strong>Vent</strong>-<strong>Axia</strong> Portable Fan Heater is a floorstanding heater with 3 settings, fan only, 1kW and2kW outputs. Variable thermostat. The unit comescomplete with a 13amp plug.Dimensions (W x H x D) 220 x 110 x 220.ModelPortable Fan HeaterGENModel Stock Ref £ TradeVAFH2TC 426715 30.61The <strong>Vent</strong>-<strong>Axia</strong> Convector Heater is lightweight,portable and is supplied with a cable and plug.Stylish and versatile, the heater may be wallmounted or installed as a floor standing unit usingthe feet included. This gives the benefit of movingthe heater to an area where you want, when youwant.For maximum safety the heater includes a thermalcut-out feature to prevent overheating.ModelConvector HeaterGENModel Stock Ref £ TradeVACH2-TC 426250 42.63SpecificationRating W H D WeightModel kW mm mm mm kgVACH2TC 2 530 370 110 2.3220-240V-50Hz. BEAB ApprovedW: www.vent-axia.com 171


Accessories & Controllers -Residential &Light CommercialFor ventilation systems to be truly efficient itis important for them to operate only whenneeded. Our range of Sentinel demandventilation systems along with our controls andsensors help respond to the exact ventilationrequirements of a room at any one time.Providing airflow only when it is required and atthe level that it is required ensures that only theenergy that is needed is used; no more no less.Approved Document L now recognises thevalue that controls can offer and you will find<strong>Vent</strong>-<strong>Axia</strong> offer a range of solutions to ensurethat you can maximise the benefit of automationwhere ever you chose to use it.Range172 T: 0844 856 0590


W: www.vent-axia.com 173


Controllers & Sensors Selection GuideController/Sensor Lo-Carbon Kinetic E & Plus E Sentinel Kinetic Range HR400 Integra Electronic speed controller Wireless remote controllerWireless enable kit* Not for use with 315 models (ACM/P/H)** For trickle/boost operation, a relay is required (442030)*** Excluding MV250H and MVDCHThe solution to the growing issues of poor indoor air quality, caused by increasing air tightness and insulation, is controlled mechanical ventilation using intermittentextract, heat recovery or central extract, wholehouse systems. Controls improve the efficiency and effectiveness of the ventilation systems through close control ofthe environment in which they are installed.<strong>Vent</strong>-<strong>Axia</strong> has the most comprehensive range of humidity sensors available on the UK market covering conventional AC, SELV and Lo-Carbon fans.174 T: 0844 856 0590


Accessories & ControlsIntegra Plus HR250 HR200V HR100R/RS Multivent Range*** Optional W: www.vent-axia.com 175


Controllers & SensorsEcotronic ControllerSurface mountingGENAn electronic controller for use with allT-Series and Standard Range models, to giveextract/intake and speed variation. Where acontroller is used with T-Series, 5-core flexible cordis required. ‘E’ running position for optimum efficiency. Finger-tip sliders. Infinitely variable speed control. Double pole On/Off switching. Extract/intake airflow direction. Neon indicator. Sensor mode for use with suitable electromechanicalswitches, eg. ThermoSwitch,HumidiSwitch to give automatic fanoperation. Adjustable minimum speed setting. Knockouts for recessed wiring. Ambient operating temperature range 0°Cto +40°C. Dimensions: 86 x 156 x 53mm(H x W x D). Supply voltage 220-240V/1/50Hz Maximum load: Ecotronic - 400 Watts Designed to meet IP20. BEAB Approved.Stock Ref£ TradeW362320 117.69T-Series® ControllerSurface mountingGENA single unit controller for use with allT-Series ventilating units. With knockouts forrecessed wiring. Where a controller is used withT-Series, 5-core flexible cord is required. 3-speed operation. High, medium or low. Finger-tip sliders. Double pole On/Off switching. Extract/intake airflow direction. Sensor mode for use with suitable electromechanicalswitches, eg. ThermoSwitch,HumidiSwitch to give automatic fan operation. Unique shutter open, fan Off setting. Neon indicator on controller. Knockouts for recessed wiring. Ambient operating temperature range 0°C to+40°C. Dimensions: 86 x 156 x 53mm(H x W x D). Supply voltage 220-240V/1/50Hz Designed to meet IP20. BEAB approved.Stock Ref£ TradeW361119 85.86TimeSwitch Controller SurfacemountingGENAdjustable automatic timer for timed ventilationof internal rooms in a variety of domestic andcommercial applications.For use with any <strong>Vent</strong>-<strong>Axia</strong> fan, within maximumrating below. The controller can be wired to thelighting circuit. Alternatively it can be connected toa door switch or any other commercially availableswitch. The ventilating unit is switched On withthe light and keeps running for a preset period ofbetween 1 and 35 minutes after the light is switchedOff. Finger-tip slider. Secret adjustable time delay feature on frontfascia. Off/auto/manual override switch. Knockouts for recessed wiring. Dimensions: 86 x 156 x 53mm (H x W x D). Ambient operating temperature range 0°Cto +40°C. Maximum load 2 amp resistive (1 ampinductive). Supply voltage 220-240V/1/50Hz Designed to meet IP20.Stock Ref£ TradeW361310 93.27Flush fittingAll Controllers on this page have the option to beflush mounted using a metal recessed box.Stock Ref£ Trade400144 9.72Registered design numbers: 1 030 207 Surface Mounting controller, 1 030 208 Flush fitting controller. Patented Remote Speed Control Circuit. European Patentnumber EP 0180311.Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operation of thesecircuits we recommend therefore that a tungsten filament light is used.176 T: 0844 856 0590


Accessories & ControlsTimeSpan ®ControllerGENAdjustable timer with overrun facility for fansventilating W.C’s and other small rooms.For use with any <strong>Vent</strong>-<strong>Axia</strong> fan within maximumrating below. The fan is switched on with the lightand keeps running for a pre-set period after the lightis switched off. Fits to any single gang box. Adjustable time delay 5-25 minutes from theback. Ambient operating temperature range 0˚Cto + 40˚C. Maximum load 250W inductive. BEAB Approved. Dimensions Controller only:87 x 87 x 33mm (H x W x D). Supply voltage 220-240V/1/50Hz.Stock Ref£ Trade563519 58.70A surface mounting back box is available.Stock Ref£ Trade410020 7.10Air Quality SensorGENAutomatically reacts to the depletion of air quality,sensing tobacco smoke, smells and toilet odoursto regulate mechanically ventilated areas such ascinemas, pubs, clubs, restaurants, kitchens, toiletsand conference rooms. This is not a CO 2sensor.The sensor switches the fan On when the air qualitydeclines below an adjustable preset level. This isregistered by the ceramic sensing head which isself-cleaning, a process which occurs every timethe unit is triggered. When the atmosphere hasreturned to normal, the fan will continue to run fora pre-set period (adjustable between 1-25 minutes)and then switch Off.The air quality sensor should not be used for thedetection of combustible gases and is not designedfor use as a smoke detector in an alarm system.For use with various <strong>Vent</strong>-<strong>Axia</strong> fans within maximumrating below.The AQS is also able to switch between trickle andboost speed on the appropriate ventilation units. Ambient operating temperature range 0°C to+50°C.. Dimensions:87 x 157 x 47mm (H x W x D). Maximum switched load: 2A inductive at 240V. Sensor consumption: 25mA at 240V. DEMKO Approved. Supply voltage 240V/1/50HzStock Ref£ Trade563506 177.37Electronic 1.5A ControllerGENSurface mounting. It will provide infinitely variablespeed control and features an On/Off/sensor sliderwith neon indicator. There is an adjustable minimumspeed setting. The controller is radio suppressed toBS EN 55014 and electrical connections for usewith suitable external sensors are provided.86 x 156 x 53mm (H x W x D). For flush fitting ametal wall box accessory is available.Hole for wall box:80x150x150mm (HxWxD)Stock Ref£ TradeW300310 80.49Hole for wall box:80x150x50mm (HxWxD)Flush fitting boxStock RefTrade400144 9.72W: www.vent-axia.com 177


Controllers & SensorsAmbient ResponseHumidity SensorGENThe latest self programming electronic On/Off wallmounted humidity sensor which reacts to any rapidincrease in humidity and temperature by switchinga <strong>Vent</strong>-<strong>Axia</strong> fan ‘On’ for rapid removal of moistureladen air, in domestic bathrooms and kitchens. Canbe wired into controller “Auto” mode connections.Night time RH increment setback feature suppressesnuisance tripping when the humidity level graduallyrises as the temperature falls. Pullcord override and neon indicator. Changeover relay switch Operating range: 30%-90%RH operatingrange. Ambient operating temperature +5˚C to+40˚C. Dimensions Controller only:87 x 87 x 33mm (H x W x D). Will fit single gang box for surface mountingStock Ref£ Trade563550 240VAC 50Hz 162.30European Patent No: 2298057Ambient Response SELV 12Humidity SensorGEN12V Safety Extra Low Voltage version for use withVA100 SELV, Solo SELV, LuminAir SELV and HR100SELV range.The latest self programming electronic On/Off wallmounted humidity sensor which reacts to any rapidincrease in humidity and temperature by switchinga <strong>Vent</strong>-<strong>Axia</strong> fan ‘On’ for rapid removal of moistureladen air, in domestic bathrooms and kitchens. Canbe wired into controller “Auto” mode connections.Night time RH increment setback feature suppressesnuisance tripping when the humidity level graduallyrises as the temperature falls. Pullcord override and neon indicator. Changeover relay switch Operating range: 30%-90%RH operatingrange. Ambient operating temperature +5˚C to+40˚C. Dimensions Controller only:87 x 87 x 33mm (H x W x D). Will fit single gang box for surface mounting.Stock Ref£ Trade563551 12VAC 50Hz 162.30Lo-Carbon AmbientResponse Humidity SensorGENDesigned specifically for the Lo-Carbon productrange. The latest self programming electronic On/Off wall mounted humidity sensor which reacts toany rapid increase in humidity and temperature byswitching a <strong>Vent</strong>-<strong>Axia</strong> fan ‘On’ for rapid removalof moisture laden air, in domestic bathrooms andkitchens. Night time RH increment setback featuresuppresses nuisance tripping when the humiditylevel gradually rises as the temperature falls. Pullcord override and neon indicator. Changeover relay switch Operating range: 30%-90%RH operatingrange. Ambient operating temperature +5˚C to+40˚C. Dimensions Controller only:87 x 87 x 33mm (H x W x D). Will fit single gang box for surface mounting.Stock Ref£ Trade563552 12VDC 162.30All of these Sensors can be wired for either On/Off or Trickle/Boost operation.Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operationof these circuits we recommend therefore that a tungsten filament light is used.178 T: 0844 856 0590


Accessories & ControlsEcotronic Humidity SensorSurface MountingGENAn adjustable set point, solid state On/Off sensor.A pullcord provides manual override, indicatedby lamp. Adjustable from 65 to 90%RH. Can bewired into controller “Auto” mode connections.Incorporates changeover switch to select low/highspeed. Setting range 65% - 90%RH. Maximum switching load 1 amp inductive. Pullcord override indicated by lamp. Ambient operating temperature 0°C to+40°C. Dimensions: 87 x 87 x 33mm.(H x W x D) Supply voltage 220-240V/1/50Hz.Stock Ref£ Trade563532 88.44Ecotronic® SELV 12 HumiditySensorGEN12V Safety Extra Low Voltage version for use withVA100 SELV, Solo SELV, and LuminAir SELV range.Incorporates changeover switch to select low/highspeed. Setting range 65% - 90%RH. Maximum switching load 5.6A @ 12V AC. Pullcord override indicated by lamp. Ambient operating temperature 0°C to+40°C. Dimensions: 87 x 87 x 33mm.(H x W x D). Supply voltage 12V AC.Stock Ref£ Trade563531 88.44Although suitable for siting within reach of ashower or bath we recommend this model islocated out of the spray zone of a bath or shower.<strong>Vent</strong>-<strong>Axia</strong> HumidiSwitchGENOperates <strong>Vent</strong>-<strong>Axia</strong> ventilating units on either a riseor a fall in humidity to control the damaging effectsof condensation. Concealed adjustment. Setting range 20% to 80% RH. Ambient 0°C to +50°C. 82 x 132 x 40mm (H x W x D). Rating 2A (1A inductive). Switching range 120-240V. Designed for use with controllers with ‘Auto’mode facility. Single pole changeover contacts.Stock Ref£ Trade563501 76.60The Ecotronic and Ecotronic SELV 12 Sensor can be wired for either On/Off or Trickle/Boost operation.W: www.vent-axia.com 179


Controllers & Sensors7 Day TimeSwitch GENFor applications where regular switching is requiredat fixed periods or at different times on differentdays of the week, eg: offices, shops, pubs andrestaurants.The 7-day TimeSwitch gives twelve On or Offpositions per day and can be set for 7 days. Thecycle will repeat until changed. Analogue clock display and integral timeswitches for ease of setting. Manual override. Removable clear plastic cover protectstimeswitch face. Volt free changeover contacts. Time base: 7 days. Shortest switching time: 2 hours. Maximum load: 16amp resistive (8ampinductive). Ambient operating temperature range -20°Cto +85°C. Dimensions:104 x 74 x 52mm (H x W x D). Supply voltage 220-240V/1/50HzStock Ref£ Trade563515 66.82<strong>Vent</strong>-<strong>Axia</strong> ThermoSwitchGENAutomatically switches On fans on either a riseor fall in air temperature. The ThermoSwitch canbe used with all <strong>Vent</strong>-<strong>Axia</strong> fans (via switchgearif appropriate) for the removal of warm air frombuildings. It can also be used to switch On Hi-Lineceiling fans for Summer cooling and to move highlevel warm air down to the working level duringWinter. Setting range: +6°C to +30°C. Two internal range limit/locking rings areincluded to allow setting within a limitedtemperature range or locking at a fixed setpoint. IP20 rated. Sealed sensing mechanism. Snap-action, single pole, changeovercontacts. Mounting direct on surface only. Electrical connection to screw type terminalswith rear or side cable entry. Dimensions:80 x 104 x 36mm (H x W x D). Contact rating: 1.5 Amp (inductive). 16 Amps (resistive) Maximum voltage 250VStock Ref£ Trade563502 30.08Guardian Personnel Detector(PIR Sensor)GENSuitable for controlling a range of <strong>Vent</strong>-<strong>Axia</strong> fans.Continuously monitors an area and activates whena moving body is detected. Supplied complete with wall mountingbracket. Adjustable timer overrun (5 seconds to 20minutes). Supplied with lens to provide 15m (max)range, 200˚ detection area. Designed to meet IP55. Ambient operating temperature range -20°Cto +50°C. Maximum load: 10 amp resistive (5 ampinductive). Suitable for use with fluorescentlighting up to 500W. Internal/External use Supply voltage 220-240V/1/50HzStock Ref£ Trade563548 102.52180 T: 0844 856 0590


Accessories & Controls<strong>Vent</strong>-<strong>Axia</strong> Visionex PIRGENA wall or ceiling mounted movement detector foruse with any domestic <strong>Vent</strong>-<strong>Axia</strong> mains voltageproduct. Also suitable for use with <strong>Vent</strong>-<strong>Axia</strong> T-Seriescontrollers on ‘Auto’ setting and ITC controllers onsensor mode. Fits any UK single gang mounting box. Adjustable timer overrun (5-25 minutes). Range of detection up to 10 metres. Designed to meet IP43. Ambient operating temperature range0°C to +50°C. Maximum load: 2.5 Amps/600W inductive.Not suitable for use with lighting. Internal use only. No switched live required for internal roomsand toilets. Double insulated. Volt-free contacts. Supply voltage 220-240V/1/50HzStock Ref£ Trade459623 91.72Surface fitting wall mounting boxStock Ref£ Trade410020 7.10<strong>Vent</strong>-<strong>Axia</strong> VisionexSELV 12 PIRGENA wall or ceiling mounted movement detector foruse with any domestic <strong>Vent</strong>-<strong>Axia</strong> SELV 12 product. Fits any UK single gang mounting box. Adjustable timer overrun (5-25 minutes). Range of detection up to 10 metres. Designed to meet IP43. Ambient operating temperature range 0°C to+50°C. Maximum load:5.6 Amps inductive @ 12V. Internal use only. No switched live required for internal roomsand toilets. Class III product. Volt-free contacts. Supply voltage 12V/1/50HzStock Ref£ Trade459624 86.54Surface fitting wall mounting boxStock Ref£ Trade410020 7.103 Pole Isolator GENIsolates Live, Neutral and Switched Live for integraltimer fans. 6 amp, 3 pole isolator complying to the3mm contact separation requirement for routinemaintenance repair.Stock Ref£ Trade563518 14.59Remote Delay TimerGENA remote delay timer for use with all domesticproducts gives the option of offering a 2 minutedelay before the fan starts. Once the fan hasstarted the overrun timer is adjustable between 5-25minutes.Stock Ref£ Trade457986 55.17W: www.vent-axia.com 181


Controllers & SensorsFan Speed AdjusterGEN5 step speed adjuster for domestic kitchen extractfans, that can reduce the speed to 40% of itsmaximum performance.Stock Ref£ Trade458153 62.58Push Button TimerGENThe <strong>Vent</strong>-<strong>Axia</strong> Push Button Timer is ideal forapplications that require an accurate timing period.Pushing the button activates the circuit, and startsthe timing period. The timer has been designed forgeneral purpose loads, a neutral feed is requiredat the switch position. This will allow the timer tobe used in various applications from incandescent,fluorescent and compact fluorescent lighting toheating and ventilation loads. Adjustable timingrange between 1 second and 2 hours.Three different modes of operation can be seton the timer to provide a variety of options to suitparticular applications.On/Off Mode: Operating the unit will start thetiming sequence. Operating the unit again duringoperation will stop the sequence immediately. If theunit is not pressed again after initial operation, thetimer will switch off after the adjustable preset timeperiod has elapsed.Resetting Mode: Operating the unit will start thetiming sequence. Operating the unit again duringoperation will restart the timing sequence.Non-Resetting Mode: Operating the unit will startthe timing sequence. Operating the unit againduring operation will have no effect.5 Step Auto Controller INDUsed in conjunction with speed controllable fansto provide 5 stepped speed without electronicmotor ‘hum’. Several fans can be connected to onetransformer provided their combined load does notexceed the controller rating.Single phase: 3.0, 5.0 and 7.5amp. Rotary switchgiving On/Off and five speeds.Output voltages at 240V/1PH/50Hz 0, 90, 115,140, 175, 240 volts.Neon indicator. Enclosures are protected to IP54.91mm x 176mm x 85mm (WxHxD).Dimensions Stock Ref £ Trade135x170x117 10314103 177.66167x219x108 10314105 218.92200x253x170 10314107 278.22Stock Ref£ Trade426416 48.78182 T: 0844 856 0590


Accessories & ControlsPIR Timer SwitchGENThe <strong>Vent</strong>-<strong>Axia</strong> PIR Timer has been designed tocontrol heating and ventilation. When body heatis no longer detected. Adjustable timing rangebetween 10 seconds and 1 hours. As these timershave been designed for general purpose loads,a neutral feed is required at the switch position.Incandescent, fluorescent and compact fluorescentlighting, heating and ventilation loads. Electricheating can be controlled, either directly or via theheater control circuit. Several timers can be wired inparallel to control the same load if required.Stock Ref£ Trade426418 101.45<strong>Vent</strong> Wise ControllerCASThe award wining <strong>Vent</strong> Wise controller has beendesigned to fully automate a ventilation system.The unit can be used on intermittent or continuoussystems, switching a fan between off and on orfrom trickle to boost speed. The controller savesenergy by only switching when cooking is takingplace or condensation is being generated. Thecurrent sensor detects when the power supply toan oven or hob is switched on. The temperaturesensor detects the rise in temperature in the hot feedto a bath or shower. A combination of up to threesensors may be used with one controller. Suitablefor 240V single phase, the <strong>Vent</strong> Wise is capableof switching 2 amps or 500 watts. Ideal for studentaccommodation, social and sheltered housing, the<strong>Vent</strong> Wise maintains indoor air quality without theneed for manual switching.160mm x 85mm x 45mm (WxHxD).Stock Ref£ Trade435960 316.06Current Sensors4m cableStock Ref£ Trade435994 72.936m cableStock Ref£ Trade435956 72.9312m cableStock Ref£ Trade435957 72.93Temperature Sensors4m cableStock Ref£ Trade435995 72.936m cableStock Ref£ Trade435958 72.9312m cableStock Ref£ Trade435959 72.93Weatherproof TouchGActivated TimerGENThe <strong>Vent</strong>-<strong>Axia</strong> Weatherproof Touch Activated Timeris designed for outdoor applications, with a 103x 103 x 65mm smooth wall enclosure. This timercan accommodate general purpose loads, and willrequire a Neutral feed at the switch position. Thiswill allow the unit to be used on various applicationsfrom incandescent, fluorescent or compactfluorescent lighting to heating and ventilation loads.The unit has two functions; it can either be used as aTimer, or as a conventional switch.Two different modes of operation can be set onthe unit:- Timing Mode: Pressing the touch plate willstart the timing sequence. Pressing the touch plateagain during operation will stop the sequenceimmediately.Switch Mode: Pressing the touch plate will switchthe unit on. Pressing the touch plate again willswitch the unit off. The timer function is disabled inthis mode.Output is via a Single Pole Change Over RelayContact, giving the option of a normally open ornormally closed contact for switching purposes. The‘temporary’ neon indicator is only illuminated whenthe unit is timing out. IP65 rated enclosure.Stock Ref£ Trade434720 149.09W: www.vent-axia.com 183


Controllers & SensorsNormal Boost SwitchGENA single gang switch to boost from high to lowspeeds on all heat recovery systems.85 x 85 x 10mm (H x W x D)Stock Ref£ Trade455213 30.39VCON6GENA double gang switch to boost from high to lowspeeds.85 x 145 x 10mm (H x W x D)Stock Ref£ Trade370356 48.12Normal Boost Purge SwitchGENA single gang switch to operate between normal,boost and purge speeds.85 x 85 x 10mm (H x W x D)Stock Ref£ Trade5108454 30.00Momentary Push SwitchCASCompatible with Sentinel Kinetic range, themomentary switch boosts the unit for 30 minutes.85 x 85 x 10mm (H x W x D)Stock Ref£ Trade437320 37.04LED IndicatorCASCompatible with the Sentinel Kinetic range, the LEDindicator illuminates when the MVHR unit requires afilter check or if the unit has a fault.Supplied with 15 metres of cable.85 x 85 x 10mm (H x W x D)Stock Ref£ Trade448356 25.00Normal Boost Switch- Stainless SteelCASA single gang switch to operate normal/boostfunctions on MVHR systems. Brushed stainless steelfinish.90 x 90 x 18 (H x W x D)Stock Ref£ Trade437320 37.04Normal Boost Switchwith Light IndicatorGENSingle gang switch with LED illumination when in theBoost condition.85 x 85 x 10mm (H x W x D)Stock Ref£ Trade449060 30.39184 T: 0844 856 0590


Accessories & Controls2-Way Switch and NeonsGENA double gang switch to boost from high to lowspeeds on all heat recovery systems, incorporatingneon lights to indicate speed settings. Suitablechangeover relay required.85 x 145 x 10mm (H x W x D).Stock Ref£ Trade459746 76.563 Speed Controller DOMA three position rotary control which enables theunit to be manually switched from permanent trickleventilation to either medium or boost speed.85 x 85 x 25mm ( H x W x D )85 x 85 x 37mm ( H x W x D ): with rotary switchStock Ref£ Trade563533 32.97VCON77 TransformerCASSurface mounted Transformer with multiple voltagesettings for optimum speed control of the HR400heat recovery unit. Provides five trickle settings tomatch various dwelling sizes when interfaced witheither a manual switch or automatic sensors. Boostspeed available at full speed only (240V).95 x 218 x 75mm (H x W x D)Stock Ref£ Trade370357 65.00HR500 ControllerDOMSurface mounting. On/Off remote sensor mode.Heat exchange, single fan extract or twin fanextract modes. Infinitely variable speed. Minimumspeed setting.Stock Ref£ TradeW14301010 126.97150VA TransformerGENSurface Mounting Transformer with six voltageselections for trickle settings to match dwellingvolume. Provides Boost/Trickle ventilation whenused with humidity sensors or a manual switch.95 x 225 x 75mm (H x W x D)Stock Ref£ Trade563538 84.87TIM2 Overrun TimerGENThe TIM2 is a remote mounting electronic overruntimer with a relay output. 2 Amp indication loadmaximum. Adjustable overrun 2-30 mins. Ideal forwhere fans are to be controlled in conjunction witha lighting circuit or activated by remote sensors.Adjustable overrun 2-30 mins.76 x 76 x 41mm. (H x W x D)Stock Ref£ Trade370346 70.12Isolator Relay ControllerCASAllows fan unit to be isolated from other mainscircuit when used with TIM2, Trickle/boost switchor light switch controlStock Ref£ Trade442030 52.09W: www.vent-axia.com 185


<strong>Vent</strong>ilation AccessoriesFixing PlatesGENA single plate available in 300mm and 450mmsquare modular sizes for permanent fixing on wallsor for use with other modular components.Manufactured in high impact recyclablethermoplastic.Unit Size Stock Ref £ Trade6 561136 34.817 561137 34.819 561139 52.7912 561142 52.79T-Series Adaptor KitsGENUsed for T-Series Window models in secondarydouble glazing, Roof models in secondary doubleglazing in exposed areas, Roof models throughroofs and Darkroom models installed through eitherroof or walls. Adaptor kits allow units to be installedon two surfaces.T-Series Adaptor kits consist of two Mounting plateswith weather-tight seals and a set of fixing screws.Unit Size Stock Ref £ Trade6 W561031 39.037 W561032 48.829 W561033 63.0912 W561034 76.60T-Series Extended FixingRod SetsGENFor use with T-Series Window and Roof modelsfitted through walls. Consists of a set of rods whichare cut to suit the wall thickness.Maximum thickness of wall 370mm.Rod thread 3.5mm.Unit Size Stock Ref £ Trade6, 7 & 9 568104 9.1412 568106 13.31‘A’ Ø<strong>Vent</strong>-<strong>Axia</strong> fixing plateUnit size ‘A’ Ø Module sizeSize 6 184mm 300 mmSize 7 222mm 300 mmSize 9 260mm 450 mmSize 12 337mm 450 mmT-Series extended fixing rod setUnit size Ref of Rods6 47 49 412 6186 T: 0844 856 0590


Accessories & ControlsWall Liner SectionDesigned for T-Series units installed in walls thickerthan 315mm, each liner section provides a maximumextension of 150mm.Wall liner section can alsoform a frame for Panel models in walls.T-Series Wall Liner’sUnit Size Stock Ref £ Tradesize 6 460094 30.02size 7 460095 34.80size 9 460096 40.84size 12 460086 44.32SPMounting BoxesGENA flanged sleeve in 300mm and 450mm squaremodular sizes used as an interconnecting sleevebetween other modular accessories.Mounting boxes will accept the depth of a unit andcan be mounted in conjunction with a Fixing plateand Eggcrate grille for ventilation through ceilings.Manufactured in flame retardant high impactrecyclable thermoplastic.Duct length 200mm.Unit Size Stock Ref £ Trade6/7 560236 81.429/12 560239 89.94<strong>Vent</strong>-<strong>Axia</strong> mounting boxUnit size Modular size6/7 300 mm9/12 450 mmJoining Bolt SetSet of 8 nuts, bolts and washersGENStock Ref£ Trade563000 5.62Single SpigotsGENSingle spigots in 300mm and 450mm squaremodular sizes. Used to connect Flexible ducting toMounting boxes and other modular accessories orcan be fixed directly to walls.Manufactured in flame retardant high impactthermoplastic.Unit Size Nom Dia Stock Ref £ Trade6 175mm(B) 560637 57.456/7 225mm(B) 560639 57.457 250mm(A) 560640 57.459 300mm(A) 560642 57.459 300mm(B) 566142 81.2712 400mm(B) 566146 81.27<strong>Vent</strong>-<strong>Axia</strong> single spigotUnit size Spigot Ø Module size6 B 175 mm 300 mm6 B 225 mm 300 mm7 B 225 mm 300 mm7 A 250 mm 300 mm9 A 300 mm 300 mm9 B 300 mm 450 mm12 B 400 mm 450 mmW: www.vent-axia.com 187


<strong>Vent</strong>ilation AccessoriesMulti-Spigot PlatesGENAvailable with 2, 3, 4 or 5 circular spigots of100mm diameter. Multi-spigot plates are used inconjunction with 100mm Flexible ducting and othermodular accessories to ventilate several small areasespecially internal lavatories. For use with Size 6units only. Manufactured in flame retardant highimpact recyclable thermoplastic.Available in 300mm square modular size.Description Stock Ref £ Trade2-3-4 Spigots 560734 59.825 Spigots 560735 67.71T-Series Direct Mount SpigotsGENUsed to connect Flexible ducting directly to the inletside of all T-Series models and the outlet side ofT-Series Window models.Manufactured in flame-retardant high impactrecyclable thermoplastic.Unit Size Stock Ref £ Trade6 All models 560501 46.707 All models 560502 50.919 WW/RF 560503 56.309 WL/PL 560504 86.4312 All models 560505 101.11T-Series Darkroom CowlAssemblyGENFor use with all T-Series fans for Darkroomapplications. Designed to give light protection.Can also be used in other light sensitive areas suchas medical, dental and veterinarian applications.Unit Size Stock Ref £ Trade6 460585 59.597 460586 67.079 460587 67.0712 460588 95.06Cone ConnectorsGENUsed in conjunction with a Size 6 *Standard Panelmodel to reduce the outlet spigot (175mm Ø) to100mm Ø flexible or rigid ducting.The Cone connector is 280mm long andincorporates a splitter for improved performance.Manufactured in flame retardant, high impactthermoplastic. Colour: Grey.Unit Size Stock Ref £ Trade6 560936 44.60*Not for use withT-Series Range.Standard Range ProtectiveGrillesGENWhere Standard Range units are installed in lowpositions, finger guards provide extra protection toVDE, DIN 31001.Standard Range internal grille (all models)Unit size Stock Ref £ Trade6 563106 12.197 563107 12.199 563109 15.8612 563112 17.79Standard Range external grille(window models)Unit size Stock Ref £ Trade6 563406 11.977 563407 11.979 563409 17.7912 563412 17.79188 T: 0844 856 0590


Accessories & ControlsPlenum BoxesGENSingle Deflection GrillesGENDouble Deflection GrillesGENThe Plenum box allows square grilles and diffusersto connect to circular duct. Each box size has atwo diameter circular spigot for maximum versatility.The box is deep enough to accommodate botha double deflection grille and opposed bladedamper.Manufactured in flame retardant high impactrecyclable thermoplastic.SIize Stock Ref Nom. Ø £ Trade200 560601 125/150 27.13250 560602 150/175 29.50300 560603 200/225 35.19300 560604 250/300 44.98450 560605 315/400 54.24Dimensions (mm)Single deflection grilles are suitable for either sidewall or exposed duct applications.The Single deflection grille has a single row ofblades which permit up to 45˚ deflection of the airin one plane.Satin silver finish.Size 6/7 fits 300mm square modular size and size9/12 fits 450mm square modular size.Module size Stock Ref £ Trade200mm sq 561370 25.76250mm sq 561371 33.03300mm sq 561372 42.11450mm sq 561373 74.66Double deflection grilles are suitable for supply airfor either side wall or exposed duct applications.The Double deflection grille has two rows of bladesset at 90˚ apart which permit up to 45˚ deflectionof the air in two planes.Satin silver finish.Size 6/7 fits 300mm square modular size and size9/12 fits 450mm square modular size.Module size Stock Ref £ Trade200mm sq 561380 41.22250mm sq 561381 53.58300mm sq 561382 67.31450mm sq 561383 123.67Stock Ref. A B CØ DØ E F560601 200 130 125 150 25 25560602 250 130 150 175 25 25560603 300 130 200 225 25 25560604 300 130 250 300 25 25560605 450 130 315 400 25 25W: www.vent-axia.com 189


<strong>Vent</strong>ilation AccessoriesEggcrate GrillesGENEggcrate grilles can be used for air replacement orair extract purposes.Used underneath Roof plate assemblies with Roofmodels, underneath Single spigots in ceilings,underneath Mounting boxes and on the inside facesof walls that have units in Fixed and Removable wallplates on the outside of the wall.Comprising a 13mm square by 13mm deep mesheggcrate core housed in a frame which has a satinsilver or white finish.Opposed Blade DampersGENOpposed blade dampers are used to regulate airflow through all <strong>Vent</strong>-<strong>Axia</strong> grilles and diffusers. Keyoperated.This action ensures that the downstream airflow isnon-directional when the damper is in the partiallyclosed position. Opposed blade dampers havealuminium blades and the frame is left in natural millfinish.Can be used in conjunction with Eggcrate, Singledeflection and Double deflection grilles.4-Way DiffusersManufactured in polypropylene plastic. Fourdiffuser cassettes can be set for downward or 45°discharge in any of sixteen directional combinations.Colour: IvoryNeck Size Stock Ref£ Trade225mm 10546230 IND 26.89300mm 10546300 IND 34.34350mm 10546350 IND 42.38400mm 10546400 GEN 51.36450mm 10546450 GEN 59.91500mm 10546500 IND 66.52Size 6/7 fits 300mm square modular size and size9/12 fits 450mm square modular size.Size 6/7 fits 300mm square modular size and size9/12 fits 450mm square modular size.500mm fits ceiling grid size 600mmoverall diffuser size, 595mmSize 6/7 - 785cm 2 free areaSize 9/12 - 1810cm 2 free area200mm Sq - 340 cm 2250mm Sq - 530 cm 2Module size Stock Ref £ Trade200mm sq 561341 26.83250mm sq 561342 34.45300mm sq 561343 42.11450mm sq 561344 70.83Satin finish.Module size Stock Ref £ Trade200mm sq 561303 33.71250mm sq 561305 47.88300mm sq 561301 49.87450mm sq 561302 74.28White finish.Module size Stock Ref £ Trade125mm sq 560846 22.71200mm sq 560847 33.71250mm sq 560848 41.50300mm sq 560849 47.63450mm sq 560850 74.28Filtered Inlet GrilleGENFor ceiling, panel or glass mounting. Consists ofa size 6 grille, washable filter, adaptor kit and astepped spigot to suit 100, 125 or 150mm diameterducting.Grille size:Spigot depth:Fixing hole diameter226mm x 220mm100mm184mmStock Ref£ TradeW563536 73.14Neck AdaptorUsed to connect Flexible ducting directly to 4-waydiffusers. Integral volume control damper for ductsizes up to 300mm.Diffuser 4-WayDuct Size Neck Size Stock Ref £ Trade150mm Ø 225mm 10547150 GEN 21.18200mm Ø 225mm 10547200 IND 24.48250mm Ø 300mm 10547250 IND 31.10300mm Ø 350mm 10547300 IND 39.93400mm Ø 400mm 10547400 GEN 46.67400mm Ø 450mm 10548400 GEN 55.55400mm Ø 500mm 10548000 IND 63.81190 T: 0844 856 0590


Accessories & ControlsWindow/Wall/CeilingTermination SetsGENUsed to terminate Flexible ducting at windows. Canbe used with the Extended fixing rod set or Fixingplates for termination at walls. Used with Flexibleducting and Worm drive clips.Consists of: Direct mount spigot, Adaptor kit,Window grille and all screws.Unit Size Spigot DiaØ Stock Ref £ Trade6 175mm W560151 91.837 225mm W560152 107.739 300mm W560153 133.6212 400mm W560154 193.66Other sizesSpigot DiaØ Stock Re £ Trade125 W10554150 94.47200 W10554200 105.93250 W10554250 117.40315 W10554315 133.99PRESSURE DROP (Pa)605040302010Wall termination sets.0 1 2 3 4 5 6 7 8MEAN DUCT VELOCITY m/sAir Replacement Non-VisionGrillesGENSatin finishNon-vision grilles consist of a single row ofoverlapping chevron vanes. Used as transfer grillesfor doors or partitions, the overlapping vanesprevent through-vision.Satin finishModule size Stock Ref £ Trade300mm sq 561311 64.27450mm sq 561312 108.67Black finishIn addition to preventing through-vision the blackfinish also limits light transference. Use two grillesback to back for darkroom applications.Module size Stock Ref £ Trade300mm sq 561321 64.27450mm sq 561322 108.67Fire DampersGENAvailable in 300mm and 450mm square modularsizes. For use with other modular accessories whena duct passes through a ceiling or wall requiring adamper to be fitted. 107mm deep.Concertina type with 71°C fusible link 2 hour rated.Manufactured in stainless steel.Size Stock Ref £ Trade6/7 561901 158.719/12 561902 197.87Roof Termination SetsGENUsed to terminate Flexible ducting at roofs.Consists of: Direct mount spigot, Adaptor kit, Roofcowl, Deflector and all screws.T-series unitsSize Spigot Ø Stock Ref £ Trade6 175 560161 114.627 225 560162 152.989 300 560163 170.7412 400 560164 270.43<strong>Vent</strong>-<strong>Axia</strong> roof terminationDiameter Stock Ref £ Trade100/125/150mm 10555150 69.94200mm 10555200 99.78250mm 10555250 141.62315mm 10555315 158.23PRESSURE DROP (Pa)605040302010Roof termination sets0 1 2 3 4 5 6 7 8MEAN DUCT VELOCITY m/sW: www.vent-axia.com 191


<strong>Vent</strong>ilation AccessoriesAir Replacement Non-VisionDoor Grilles with Matching FlangesGENNon-vision grilles consist of a single row ofoverlapping chevron vanes to prevent throughvision,supplied with matching flanges. The grilleis fitted to one side of the door with the matchingflange on the other side.Suitable for door thicknesses of 19-49mm.Available in Silver or Brown finish, in two sizes, 600x 150 and 600 x 300mm.Satin finishSize Stock Ref £ Trade600 x 150mm 561390 99.49600 x 300mm 561391 145.22Brown finishSize Stock Ref £ Trade600 x 150mm 560900 99.49600 x 300mm 560901 145.22Heavy Duty T-SeriesWall GrillesGENTough aluminum construction for accesible publicareas. Fits T-Series wall models in place of existingexternal grille. Finish T-Series grey.Size Stock Ref £ Trade6 452725 67.487 452726 78.509 452727 85.0312 452728 95.08External Louvres Mill andBrown FinishGENWeather resistant external louvres are suitable forair intake or discharge and for use with ducting onexternal walls.The narrow blade construction has a 38mm pitchset at 45° with a depth of 41mm and an integralrain lip.Standard 32mm wide undrilled outer flangesin aluminium have fully welded mitre corners asstandard.Size 6/7 fits 300mm square modular size and size9/12 fits 450mm square modular size.Size 6/7 - 345cm 2 free areaSize 9/12 - 824cm v free areaSatin finishSize Stock Ref £ Trade225mm sq 561350 70.83300mm sq 561351 72.75400mm sq 561355 103.83450mm sq 561352 120.77Brown finishSize Stock Ref £ Trade225mm sq 560910 66.75300mm sq 560911 74.76400mm sq 560912 113.00450mm sq 560913 134.03Louvre GrillesGENLouvre grilles can be used for air replacement,for extract purposes and as an external louvre.Available in four sizes, the assembly fits over ratherthan into the aperture making it especially usefulwhere there are space restrictions within the duct.Manufactured in thermoplastic. Choice of threecolours: White, Brown and Grey.Size 6 - 190cm 2 free areaSize 7 - 335cm 2 free areaSize 9 - 415cm 2 free areaSize 12 - 705cm 2 free areaGrille Dimensions (mm)Sizew x hSize 6 = 310 x 303Size 7 = 352 x 345Size 9 = 391 x 388Size 12 = 470 x 467The grilles and surrounds are moulded in ABSplastic to tone with building materials, therefore anequivalent BS or RAL colour reference cannot begiven.Unit Size Colour Stock Ref £ Trade6 Grey W561431 33.876 Brown 561411 33.876 White 561421 33.877 Grey W561432 40.667 Brown 561412 40.667 White 561422 40.669 Grey W561433 50.219 Brown 561413 50.209 White 561423 50.2012 Grey W561434 63.9812 Brown 561414 63.9812 White 561424 63.98192 T: 0844 856 0590


Accessories & ControlsRoof Plate AssembliesGEN<strong>Vent</strong>-<strong>Axia</strong> roof plate assemblies are manufactured inhigh impact recyclable thermoplastic. They consistof a strong one piece moulded plate with extendedsides to assist flashing and weather protection. Aseparate sub-frame is provided for permanentfixing to the roof kerb. The <strong>Vent</strong>-<strong>Axia</strong> Roof modelis then fitted to the plate using a suitable sealingcompound between the Cowl and plate, ensuringa weather-tight seal.Size Stock Ref £ Trade6 560136 116.267 560137 116.269 560139 133.5912 560142 133.595-Core Flexible CordGENMulti-core flexible cord specially manufactured foruse with all <strong>Vent</strong>-<strong>Axia</strong> Standard and T-Series units.White sheath with colour coded cores. Availableby the metre (minimum 5m) or by the 50 metre coil.Cable size: 0.75mm 2 .Stock Ref£ TradePer 50 metre 562031 93.66Cut length 562030 3.10(per metre min 5m)Standard Range Adaptor KitsGENUsed for Standard Range Window modelsin secondary double glazing, Roof models insecondary double glazing in exposed areas andRoof models through roofs.Adaptor kits allow units to be installed on twosurfaces.Adaptor kits consist of an additional shroud andgasket, locking ring and seal. The shroud andgasket fit to the outside part of the unit, the lockingring and seal going to the inside part.Fitting through holes in both Fixing Plates or glass,<strong>Vent</strong>-<strong>Axia</strong>’s spigot and ring method of fixing allowssimple installation separately to both parts.Colour: Ivory.Unit size Stock Ref £ Trade6 561011 39.037 561012 48.819 561013 63.0912 561014 76.60Size A B C6 300mm 335mm 65mm7 300mm 335mm 65mm9 450mm 490mm 15mm12 450mm 490mm 15mmIn addition to the size 6, 7, 9 & 12 Roof TerminationSets, the Roof Plate Assemblies can also be usedwith the following Roof Terminations part numbers.10555150 use size 6 Roof Plate Assembly10555200 use size 7 Roof Plate Assembly10555250 use size 9 Roof Plate Assembly10555315 use size 12 Roof Plate AssemblyJoining PiecesGENUsed to join lengths of flexible ducting to give along-lasting airtight connection.Duct Size Stock Ref £ Trade100mm Ø 561804 8.09125mm Ø 561805 9.77150mm Ø 561806 11.42175mm Ø 561807 11.81200mm Ø 561808 11.99225mm Ø 561809 13.64250mm Ø 561810 16.25300mm Ø 561812 19.24315mm Ø 561813 19.53400mm Ø 561816 20.26Worm Drive ClipsGENStainless steel tightening band with quick-fixscrewed ends for securing flexible ducting.Max. Ø Stock Ref £ Trade110mm 561704 2.26215mm 561707 3.05270mm 561710 4.03380mm 561715 4.58525mm 561720 4.99660mm 561726 5.13W: www.vent-axia.com 193


Industrialfrom <strong>Vent</strong>-<strong>Axia</strong>The Roof Units TM name has long been associated with highquality ventilation products at affordable prices. With ERP2013 compliance assured for January 2013 you can becertain of high quality ventilation products meeting the exactdemands of today.The extensive Roof Units TM product range includes theEuroseries TM <strong>Axia</strong>l plate, short cased & roof fans, as well asinline centrifugal extract fans and twin fans. When matchedwith the Roof Units TM and <strong>Vent</strong>-<strong>Axia</strong> ranges of controllers,flexible ducting and other accessories you can be certain offulfilling the complete installation from one supplier.Characterised by design excellence, Roof Units TM fansare purpose designed to deliver controllable outputs ofup to 15m 3 /s, plus the right balance of airflow, pressuredevelopment, quietness and energy efficiency for every typeof project.The Euroseries TM range of <strong>Axia</strong>l bladed fans cover plate,short cased & roof variants, all fully speed controllable,incorporating modern high efficiency external rotor motorswith single piece die-cast aluminium rotor/impellors offeringsmoother running & giving longer reliable service life.Its all in this fully illustrated catalogue, which includes fullperformance data and specifications – facilitating yourselection for the right ventilation solution.Range194 T: 0844 856 0591


W: www.vent-axia.com 195


EuroSeries® (ESP)Plate Mounted <strong>Axia</strong>l Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits Die cast aluminium impellors Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 315 to 1000 dia protected to IP54 Operating Temperatures from -40°C up to +70°C Motor Insulation Class F Thermal overload for motor protection All units reversible - Supply or Extract Tough epoxy paint finish Quality Assurance to BS EN ISO 9001:1994 Performance tested to ISO 5801Dimensions (mm)Dia a b Øc Ød e f g h Øj Kg250 370 320 256.5 264.5 84 80 6 80 9 3.4315 430 380 320 328 84 84 19 70 9 6.3355 485 435 367 372 86 97 21 75 9 7.3400 540 490 412 420 93 100 12 88 9 10.2450 575 535 463 480 86 139 14 96 11 15.8500 655 615 517 528 84 141 16 104 11 17.3560 725 675 568 589 81 142.5 16 119 11 24630 805 750 643 664 82 142.5 20 130 11 45710 850 810 720 763 37 176.5 20 150 14.5 31800 970 910 804 869 34 244 17 193 14.5 381000 1170 1110 1009 1067 40 284 20 200 14.5 84196 T: 0844 856 0590


Roof UnitsPerformance GuideFan IP m3 /s Motor S.C. F.L.C. dBASize Phase Pole Stock Ref RPM Rating 0 25 50 70 100 125 150 200 225 250 300 kW Amps Amps @ 3m250 1 2 ESP25012 2440 IP44 0.46 0.42 0.4 0.37 0.31 0.21 0.14 0.14 1.15 0.6 59250 3 2 ESP25032 2700 IP44 0.59 0.57 0.55 0.53 0.5 0.45 0.35 2.5 0.63 61315 1 2 ESP31512 2690 IP54 1.02 0.98 0.96 0.92 0.88 0.84 0.8 0.68 0.48 6 2.1 64315 3 2 ESP31532 2800 IP54 1.06 1.03 1.01 0.98 0.95 0.92 0.89 0.81 0.69 0.48 5 0.9 60250 1 4 ESP25014 1340 IP44 0.21 0.17 0.12 0.07 0.04 0.3 0.16 44315 1 4 ESP31514 1300 IP54 0.57 0.5 0.42 0.34 0.15 1.38 0.7 50315 3 4 ESP31534 1390 IP54 0.58 0.52 0.44 0.35 0.11 2.1 0.27 46355 1 4 ESP35514 1330 IP54 0.96 0.87 0.76 0.63 0.19 1.45 0.84 53355 3 4 ESP35534 1370 IP54 1 0.92 0.83 0.71 0.17 1.35 0.37 49400 1 4 ESP40014 1350 IP54 1.4 1.28 1.16 0.97 0.29 2.4 1.45 56400 3 4 ESP40034 1350 IP54 1.48 1.38 1.28 1.08 0.26 2.1 0.56 51450 1 4 ESP45014 1370 IP54 1.72 1.6 1.46 1.34 1.11 0.36 3.6 1.6 61450 3 4 ESP45034 1380 IP54 1.8 1.7 1.59 1.43 1.24 0.36 2.6 0.8 56500 1 4 ESP50014 1290 IP54 2.1 1.97 1.82 1.64 1.41 0.51 4.3 2.3 55500 3 4 ESP50034 1380 IP54 2.27 2.15 2.05 1.9 1.75 1.54 0.55 3.7 1.05 58560 1 4 ESP56014 1320 IP54 3.72 3.58 3.44 3.32 3.11 2.94 2.71 1.4 9.3 6 63560 3 4 ESP56034 1220 IP54 3.43 3.24 3.08 2.92 2.67 2.38 2.05 1 7 1.8 70630 1 4 ESP63014 1320 IP54 5.09 4.92 4.77 4.62 4.41 4.26 4.02 3.47 3.14 2.72 2.2 28 9.9 70630 3 4 ESP63034 1360 IP54 5.19 5.01 4.86 4.71 4.47 4.23 4.02 3.41 1.9 14 3.2 64710 3 4 ESP71034 1290 IP54 6.81 6.65 6.49 6.34 6.16 5.94 5.72 5.22 4.82 4.42 2.9 19 5.3 72800 3 4 ESP80034 1270 IP54 10.39 10.1 9.81 9.57 9.18 8.79 8.45 7.73 7.2 6.72 5.51 4.7 29 8.3 78355 1 6 ESP35516 950 IP54 0.69 0.53 0.09 1.2 0.46 44355 3 6 ESP35536 910 IP54 0.62 0.35 0.09 0.5 0.25 45400 1 6 ESP40016 940 IP54 0.98 0.81 0.13 1.4 0.6 45400 3 6 ESP40036 920 IP54 0.96 0.79 0.11 0.9 0.28 50450 1 6 ESP45016 915 IP54 1.15 0.99 0.17 2.7 0.77 50450 3 6 ESP45036 890 IP54 1.16 1 0.75 0.12 1 0.28 51500 1 6 ESP50016 910 IP54 1.45 1.27 0.96 0.25 4.74 1.35 54500 3 6 ESP50036 900 IP54 1.52 1.35 1.16 0.23 1.5 0.56 56560 1 6 ESP56016 880 IP54 2.46 2.25 1.95 1.65 0.43 4.6 1.95 56560 3 6 ESP56036 860 IP54 2.39 2.15 1.83 1.42 0.39 1.75 0.81 56630 1 6 ESP63016 880 IP54 3.33 3.06 2.75 2.46 0.6 5.3 2.7 57630 3 6 ESP63036 890 IP54 3.37 3.1 2.8 2.48 0.59 3.6 1.3 59710 1 6 ESP71016 850 IP54 4.56 4.24 3.9 3.53 0.89 8 4.1 60710 3 6 ESP71036 860 IP54 4.71 4.41 4.11 3.8 3.29 1.1 7.7 2.2 62800 3 6 ESP80036 900 IP54 6.3 5.94 5.58 5.22 4.67 3.95 1.4 9.8 2.7 641000 3 6 ESP100036 935 IP54 13.89 13.35 13.04 12.73 12.35 11.92 11.46 10.88 10.26 9.72 5.5 67 10.5 77630 3 8 ESP63038 630 IP54 1.79 1.29 0.31 1.5 0.65 55710 3 8 ESP71038 630 IP54 3.4 2.98 2.37 0.43 3.3 1.1 55800 3 8 ESP80038 670 IP54 4.82 4.35 3.84 0.69 5 1.75 581000 3 8 ESP100038 670 IP54 9.78 9.35 8.91 8.42 7.66 6.63 2.2 13 4.2 65For fans wired to reverse run, duty reduced by 30%W: www.vent-axia.com 197


EuroSeries® (ESP)Models & AccessoriesSpeed ControllersFan Elect 1ph Auto Starter OverloadStock Ref Stock Ref Transfor. Stock Ref Stock Ref1 Phase - 2 PoleESP25012 SP5001 SPM5020 444744 444699ESP31512 SP5025 SPM5035 444744 4447011 Phase - 4 PoleESP25014 SP5001 SPM5020 444744 444696ESP31514 SP5001 SPM5020 444744 444699ESP35514 SP5001 SPM5020 444744 444699ESP40014 SP5025 SPM5020 444744 444701ESP45014 SP5025 SPM5020 444744 444701ESP50014 SP5025 SPM5035 444744 444702ESP56014 SP5010 SPM5075 444744 444704ESP63014 - SPM5140 444744 4447061 Phase - 6 PoleESP35516 SP5001 SPM5020 444744 444698ESP40016 SP5001 SPM5020 444744 444699ESP45016 SP5001 SPM5020 444744 444699ESP50016 SP5025 SPM5020 444744 444700ESP56016 SP5025 SPM5035 444744 444701ESP63016 SP5050 SPM5035 444744 444702ESP71016 SP5050 SPM5060 444744 444703All red highlighted text GENAll blue highlighted text INDLouvre Shutter Impeller Discharge Side Guard Imp. Disch. Guard when used with a LS shutterSize Stock Ref Stock Ref Stock Ref250 LS250 10502325 10502375315 LS315 10502325 10502375355 LS350 10502375 10502450400 LS400 10502450 10502525450 LS450 10502525 10502630500 LS500 10502525 10502630560 LS560 10502630 10502630630 LS630 10502630 10502800710 LS710 10502800 10502800800 LS800 10502800 1050210001000 LS1000 105021000 -Note:- The Standard roof cowl colour is BS 00A 05 (Goose Wing Grey), for all special B.S. or RAL colours (contact <strong>Vent</strong>-<strong>Axia</strong>).- When speed control is required a 5 step auto transformer speed controller is recommended, to ensure low noise levels.- All 3 phase models are suitable for frequency inverter speed control.198 T: 0844 856 0590


Roof UnitsSpeed ControllerFan Auto Transfor. Starter OverloadStock Ref Stock Ref Stock Ref Stock Ref3 Phase - 2 PoleESP25032 RDTK10 444747 444699ESP31532 RDTK20 444747 444700ESP35532 RDTK40 444747 4447023 Phase - 4 PoleESP31534 RDTK10 444747 444697ESP35534 RDTK10 444747 444698ESP40034 RDTK10 444747 444699ESP45034 RDTK10 444747 444699ESP50034 RDTK20 444747 444700ESP56034 RDTK40 444747 444701ESP63034 RDTK40 444747 444702ESP71034 RDTK70 444747 444703ESP80034 RD14 444747 4447053 Phase - 6 PoleESP35536 RDTK10 444747 444697ESP40036 RDTK10 444747 444697ESP45036 RDTK10 444747 444697ESP50036 RDTK10 444747 444699ESP56036 RDTK10 444747 444699ESP63036 RDTK20 444747 444700ESP71036 RDTK40 444747 444702ESP80036 RDTK40 444747 444702ESP100036 RD14 444748 4447063 Phase - 8 PoleESP63038 RDTK10 444747 444699ESP71038 RDTK20 444747 444700ESP80038 RDTK20 444747 444701ESP100038 RDTK70 444747 444703W: www.vent-axia.com 199


fEuroSeries® (ESC)Short Case <strong>Axia</strong>l Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits External rotor motors Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 protected to IP54 Operating Temperatures from -40°C up to+70°C Motor Insulation Class F HOT SPOT Protection All units reversible for supply or extract Tough epoxy paint finish Quality Assurance to BS EN ISO9001:1994 Performance tested to BS848 Part 1 1980Dimensions (mm)EØCØBpcdAØDia ØA ØB ØC D ØE n kg250 254 286 306 110 7 8 5315 316.5 356 382 135 9.5 8 6.1355 356 395 421 135 9.5 8 7.1400 400 438 466 155 9.5 12 8.1450 451 487 515 160 9.5 12 13.4500 503 541 567 166 9.5 12 15.7560 559 605 635 210 11.5 16 20.1630 634 674 707 220 11.5 16 44710 711 751 785 260 11.5 16 31800 797 837 871 280 11.5 24 391000 1001 1043 1080 330 11.5 24 7365DTo complement the Euroseries fans, we offer acomprehensive range of purpose made ancillaryitems. These can be purchased individually, or formore convenience and economy, they are alsoavailable as an ancillary pack containing: 4 - Anti vibration mountings 2 - Feet per ancillary pack 2 - Matching flanges2 - Sound barrier flexible connectors(with clips)Mounting Feetdf Øe ØebhStock Ref. a b c d Øe f g h iMFZ315 315 40 265 200 10 20 71 178 166MFZ355 350 40 300 225 10 20 81.5 198 186MFZ400 250 40 220 250 10 20 78 219 205MFZ450 275 40 240 275 10 20 82 244 230MFZ500 315 50 280 315 1 25 100 271 255MFZ560 355 50 320 355 12 25 97 303 285MFZ630 400 50 360 400 12 25 109 337 320MFZ710 465 50 415 450 12 25 119 376 362MFZ800 458 50 420 518 12 25 176 419 405Anti Vibration Mountingsag Øe ØStock ref a b c d e f g68MP033G 27 37 54 67 7 3 M8caic ctsdgbCoupling FlangesQ150FlexibleConnectionHKa ØØaMatchingFlangeMNumber of holesnØc ØdbJMØeConnectionStock Ref. Øa b Øc Ød Øe n FlexibleCFZ315 313 40 356 382 10 8 FCZ315CFZ355 353 40 395 421 10 8 FCZ355CFZ400 398 45 438 466 10 12 FCZ400CFZ450 448 45 487 515 10 12 FCZ450CFZ500 498 45 541 567 10 12 FCZ500CFZ560 558 45 605 635 12 16 FCZ560CFZ630 628 45 674 707 12 16 FCZ630CFZ710 708 50 751 785 12 16 FCZ710CFZ800 798 50 837 871 12 24 FCZ800FlangeDrillings toMatch FanAnti VibrationMountingsP Hole ØUnit size H J K† M P Q315 200 265 27 54 7 40355 225 300 27 54 7 40400 250 220 27 54 7 45450 275 240 27 54 7 45500 315 280 27 54 7 45560 355 320 27 54 7 45630 400 360 27 54 7 45710 450 415 27 54 7 50800 518 420 27 54 7 50200 T: 0844 856 0590


Roof UnitsPerformance GuideFan IP m 3 /s Motor S.C. F.L.C. dBASize Phase Stock Ref RPM Rating 0 25 50 70 100 125 150 200 225 250 300 kW Amps Amps @ 3m2 Pole250 1 ESC25012 2440 IP44 0.46 0.42 0.4 0.37 0.31 0.21 0.14 0.14 1.15 0.6 59250 3 ESC25032 2700 IP44 0.59 0.57 0.55 0.53 0.5 0.45 0.35 2.5 0.63 61315 1 ESC31512 2690 IP54 1.02 0.98 0.96 0.92 0.88 0.84 0.8 0.68 0.48 6 2.1 64315 3 ESC31532 2800 IP54 1.06 1.03 1.01 0.98 0.95 0.92 0.89 0.81 0.69 0.48 5 0.9 60355 1 ESC35512 2800 IP54 1.4 1.37 1.33 1.3 1.26 1.21 1.18 1.05 1 0.93 1.05 19 4.45 71355 3 ESC35532 2700 IP54 1.42 1.37 1.33 1.3 1.27 1.22 1.18 1.07 1.01 0.89 1.05 8 2.2 734 Pole250 1 ESC25014 1340 IP44 0.21 0.17 0.12 0.07 0.04 0.3 0.16 44315 1 ESC31514 1300 IP54 0.57 0.5 0.42 0.34 0.15 1.38 0.7 50315 3 ESC31534 1390 IP54 0.58 0.52 0.44 0.35 0.11 2.1 0.27 46355 1 ESC35514 1330 IP54 0.96 0.87 0.76 0.63 0.19 1.45 0.84 53355 3 ESC35534 1370 IP54 1 0.92 0.83 0.71 0.17 1.35 0.37 49400 1 ESC40014 1350 IP54 1.4 1.28 1.16 0.97 0.29 2.4 1.45 56400 3 ESC40034 1350 IP54 1.48 1.38 1.28 1.08 0.26 2.1 0.56 51450 1 ESC45014 1370 IP54 1.72 1.6 1.46 1.34 1.11 0.36 3.6 1.6 61450 3 ESC45034 1380 IP54 1.8 1.7 1.59 1.43 1.24 0.36 2.6 0.8 56500 1 ESC50014 1290 IP54 2.1 1.97 1.82 1.64 1.41 0.51 4.3 2.3 55500 3 ESC50034 1380 IP54 2.27 2.15 2.05 1.9 1.75 1.54 0.55 3.7 1.05 58560 1 ESC56014 1320 IP54 3.72 3.58 3.44 3.32 3.11 2.94 2.71 1.4 9.3 6 63560 3 ESC56034 1220 IP54 3.43 3.24 3.08 2.92 2.67 2.38 2.05 1 7 1.8 70630 1 ESC63014 1320 IP54 5.09 4.92 4.77 4.62 4.41 4.26 4.02 3.47 3.14 2.72 2.2 28 9.9 70630 3 ESC63034 1360 IP54 5.19 5.01 4.86 4.71 4.47 4.23 4.02 3.41 1.9 14 3.2 64710 3 ESC71034 1290 IP54 6.81 6.65 6.49 6.34 6.16 5.94 5.72 5.22 4.82 4.42 2.9 19 5.3 72800 3 ESC80034 1270 IP54 10.39 10.1 9.81 9.57 9.18 8.79 8.45 7.73 7.2 6.72 5.51 4.7 29 8.3 786 Pole355 1 ESC35516 950 IP54 0.69 0.53 0.09 1.2 0.46 44355 3 ESC35536 910 IP54 0.62 0.35 0.09 0.5 0.25 45400 1 ESC40016 940 IP54 0.98 0.81 0.13 1.4 0.6 45400 3 ESC40036 920 IP54 0.96 0.79 0.11 0.9 0.28 50450 1 ESC45016 915 IP54 1.15 0.99 0.17 2.7 0.77 50450 3 ESC45036 890 IP54 1.16 1 0.75 0.12 1 0.28 51500 1 ESC50016 910 IP54 1.45 1.27 0.96 0.25 4.74 1.35 54500 3 ESC50036 900 IP54 1.52 1.35 1.16 0.23 1.5 0.56 56560 1 ESC56016 880 IP54 2.46 2.25 1.95 1.65 0.43 4.6 1.95 56560 3 ESC56036 860 IP54 2.39 2.15 1.83 1.42 0.39 1.75 0.81 56630 1 ESC63016 880 IP54 3.33 3.06 2.75 2.46 0.6 5.3 2.7 57630 3 ESC63036 890 IP54 3.37 3.1 2.8 2.48 0.59 3.6 1.3 59710 1 ESC71016 850 IP54 4.56 4.24 3.9 3.53 0.89 8 4.1 60710 3 ESC71036 860 IP54 4.71 4.41 4.11 3.8 3.29 1.1 7.7 2.2 62800 3 ESC80036 900 IP54 6.3 5.94 5.58 5.22 4.67 3.95 1.4 9.8 2.7 641000 3 ESC100036 935 IP54 13.89 13.35 13.04 12.73 12.35 11.92 11.46 10.88 10.26 9.72 5.5 67 10.5 77For Fans wired to reverse run, duty reduced by 30%W: www.vent-axia.com 201


EuroSeries® (ESC)Models & AccessoriesSpeed ControllerSpeed ControllerFan Electronic Starter Overload Fan Auto Transfor.Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref1 Phase 2 Pole 3 Phase 2 PoleESC25012 SP5001 SPM5020 444744 444699 ESC25032 RDTK10ESC31512 SP5025 SPM5035 444744 444701 ESC31532 RDTK10ESC35512 SP5050 SPM5060 444744 444703 ESC35532 RDTK401 Phase 4 Pole 3 Phase 4 PoleESC25014 SP5001 SPM5020 444744 444696ESC31514 SP5001 SPM5020 444744 444699 ESC31534 RDTK10ESC35514 SP5001 SPM5020 444744 444699 ESC35534 RDTK10ESC40014 SP5025 SPM5020 444744 444701 ESC40034 RDTK10ESC45014 SP5025 SPM5020 444744 444701 ESC45034 RDTK10ESC50014 SP5025 SPM5035 444744 444702 ESC50034 RDTK20ESC56014 SP5010 SPM5075 444744 444704 ESC56034 RDTK40ESC63014 SPM5140 444744 444706 ESC63034 RDTK40ESC71034ESC80034RDTK70RD141 Phase 6 Pole 3 Phase 6 PoleESC35516 SP5001 SPM5020 444744 444698 ESC35536 RDTK10ESC40016 SP5001 SPM5020 444744 444699 ESC40036 RDTK10ESC45016 SP5001 SPM5020 444744 444699 ESC45036 RDTK10ESC50016 SP5025 SPM5020 444744 444700 ESC50036 RDTK10ESC56016 SP5025 SPM5035 444744 444701 ESC56036 RDTK10ESC63016 SP5050 SPM5035 444744 444702 ESC63036 RDTK20ESC71016 SP5050 SPM5060 444744 444703 ESC71036 RDTK40ESC80036ESC100036RDTK40RD14All red highlighted text GEN All blue highlighted text IND1D Long - No Pod 1D Long - With Pod 2D Long - No Pod 2D Long - With PodSize Stock Ref £Trade Stock Ref £Trade Stock Ref £Trade Stock Ref £Trade250 ACZ2501D -- ACZ2502D -315 ACZ3151D ACZ3151DP ACZ3152D ACZ3152DP355 ACZ3551D ACZ3551DP ACZ3552D ACZ3552DP400 ACZ4001D ACZ4001DP ACZ4002D ACZ4002DP450 ACZ4501D ACZ4501DP ACZ4502D ACZ4502DP500 ACZ5001D ACZ5001DP ACZ5002D ACZ5002DP560 ACZ5601D ACZ5601DP ACZ5602D ACZ5602DP630 ACZ6301D ACZ6301DP ACZ6302D ACZ6302DP710 ACZ7101D ACZ7101DP ACZ7102D ACZ7102DP800 ACZ8001D ACZ8001DP ACZ8002D ACZ8002DP202 T: 0844 856 0590


Roof UnitsStarter Overload Ancillary Packs Mounting Feet (pair) Matching Flanges (each) Wire Guards (each) Anti.Vib. Mnts (set of 4)Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref444747 444699 APZ250 MFZ250 CFZ250 WGZ250 68MP033G444747 444700 APZ315 MFZ315 CFZ315 WGZ315 68MP033G444747 444702 APZ355 MFZ355 CFZ355 WGZ355 68MP033GAPZ250 MFZ250 CFZ250 WGZ250 68MP033G444747 444697 APZ315 MFZ315 CFZ315 WGZ315 68MP033G444747 444698 APZ355 MFZ355 CFZ355 WGZ355 68MP033G444747 444699 APZ400 MFZ400 CFZ400 WGZ400 68MP033G444747 444699 APZ450 MFZ450 CFZ450 WGZ450 68MP033G444747 444700 APZ500 MFZ500 CFZ500 WGZ500 68MP033G444747 444701 APZ560 MFZ560 CFZ560 WGZ560 68MP033G444747 444702 APZ630 MFZ630 CFZ630 WGZ630 68MP033G444747 444703 APZ710 MFZ710 CFZ710 WGZ710 68MP033G444747 444705 APZ800 MFZ800 CFZ800 WGZ800 68MP033G444747 444697 APZ355 MFZ355 CFZ355 WGZ355 68MP033G444747 444697 APZ400 MFZ400 CFZ400 WGZ400 68MP033G444747 444697 APZ450 MFZ450 CFZ450 WGZ450 68MP033G444747 444699 APZ500 MFZ500 CFZ500 WGZ500 68MP033G444747 444699 APZ560 MFZ560 CFZ560 WGZ560 68MP033G444747 444700 APZ630 MFZ630 CFZ630 WGZ630 68MP033G444747 444702 APZ710 MFZ710 CFZ710 WGZ710 68MP033G444747 444702 APZ800 MFZ800 CFZ800 WGZ800 68MP033GNote:- The Standard roof cowl colour is BS 00A 05 (Goose Wing Grey) for all special B.S. or RAL colours (contact <strong>Vent</strong>-<strong>Axia</strong>).- When speed control is required a 5 step auto transformer speed controller is recommended, to ensure low noise levels.- All 3 phase models are suitable for frequency inverter speed control.W: www.vent-axia.com 203


EuroSeries® (ESR)Roof Mounting <strong>Axia</strong>l Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 315 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm) All models speed controllable Motor Insulation Class F, -40°C to +70°C operating temperature Reversible for supply or extract units Thermal overload for motor protection Performance tested to BS848 part 1 1980Fan Dimensions (mm)dea50100Purlin Box (mm)bcfeCRS.dCRS.b a bcfKerb detailSize a b c d e f g250 625 90 240 765 400 590 460315 625 90 240 765 400 590 460355 625 90 240 765 400 590 460400 725 90 240 865 500 705 565450 725 90 240 865 500 705 565500 890 70 250 990 650 850 640560 890 70 250 990 650 870 700630 1030 75 250 1140 760 985 775710 1030 75 250 1140 760 985 840800 980 37 267 1016 406 980 8801000 1180 76 279 1294 508 1180 1080Size a b c d e f kg Max250 700 475 737 411 97 675 13.25315 700 475 737 411 97 675 16.3355 700 475 737 411 97 675 16.3400 800 575 830 466 97 775 18.4450 800 575 830 466 97 775 20.3500 950 715 1000 579 100 915 35.5560 950 715 1000 579 100 915 35.5630 1230 840 1100 731 105 1040 62710 1230 840 1100 731 105 1040 62800 1420 870 1190 731 105 1070 781000 1680 1070 1455 795 131 1270 134204 T: 0844 856 0590


Roof UnitsPerformance GuideFan m 3 /s Motor S.C. F.L.C. dBASize Phase Stock Ref RPM IP Rating 0 25 50 70 100 125 150 200 225 250 300 kW Amps Amps @ 3m2 Pole250 1 ESR25012 2440 IP44 0.28 0.24 0.22 0.19 0.136 0.09 0.14 1.15 0.6 59250 3 ESR25032 2700 IP44 0.41 0.39 0.37 0.35 0.32 0.27 0.35 2.5 0.63 61315 1 ESR31512 2690 IP54 0.84 0.8 0.78 0.74 0.7 0.66 0.62 0.5 0.48 6 2.1 64315 3 ESR31532 2800 IP54 0.88 0.85 0.83 0.8 0.77 0.74 0.71 0.63 0.51 0.48 5 0.9 604 Pole250 1 ESR25014 1340 IP44 0.3 0.04 0.3 0.16 44315 1 ESR31514 1300 IP54 0.38 0.32 0.24 0.16 0.15 1.38 0.7 50315 3 ESR31534 1390 IP54 0.4 0.34 0.26 0.17 0.11 2.1 0.27 46355 1 ESR35514 1330 IP54 0.78 0.69 0.58 0.45 0.19 1.45 0.84 53355 3 ESR35534 1370 IP54 0.82 0.74 0.65 0.53 0.17 1.35 0.37 49400 1 ESR40014 1350 IP54 1.14 1.02 0.89 0.7 0.29 2.4 1.45 56400 3 ESR40034 1350 IP54 1.21 1.11 1.01 0.81 0.26 2.1 0.56 51450 1 ESR45014 1370 IP54 1.45 1.33 1.19 1.07 0.85 0.36 3.6 1.6 61450 3 ESR45034 1380 IP54 1.54 1.43 1.32 1.17 0.98 0.36 2.6 0.8 56500 1 ESR50014 1290 IP54 1.43 1.31 1.15 0.98 0.75 0.51 4.3 2.3 55500 3 ESR50034 1380 IP54 1.61 1.49 1.38 1.23 1.09 0.87 0.55 3.7 1.05 58560 1 ESR56014 1320 IP54 3.05 2.91 2.77 2.65 2.44 2.28 2.04 1.4 9.3 6 63560 3 ESR56034 1220 IP54 2.76 2.58 2.41 2.25 2 1.72 1.39 1 7 1.8 70630 1 ESR63014 1320 IP54 4.38 4.21 4.06 3.91 3.7 3.55 3.31 2.76 2.43 2.01 2.2 28 9.9 70630 3 ESR63034 1360 IP54 4.49 4.3 4.15 4 3.76 3.52 3.31 2.7 1.9 14 3.2 64710 3 ESR71034 1290 IP54 6.1 5.96 5.78 5.63 5.45 5.23 5.02 4.51 4.11 3.71 2.9 19 5.3 72800 3 ESR80034 1270 IP54 8.89 8.6 8.31 8.07 7.68 7.29 6.96 6.23 5.7 5.22 4.01 4.7 29 8.3 786 Pole355 1 ESR35516 950 IP54 0.51 0.35 0.09 1.2 0.46 44355 3 ESR35536 910 IP54 0.44 0.17 0.09 0.5 0.25 45400 1 ESR40016 940 IP54 0.72 0.55 0.13 1.4 0.6 45400 3 ESR40036 920 IP54 0.7 0.53 0.11 0.9 0.28 50450 1 ESR45016 915 IP54 0.89 0.73 0.17 2.7 0.77 50450 3 ESR45036 890 IP54 0.89 0.74 0.48 0.12 1 0.28 51500 1 ESR50016 910 IP54 0.79 0.6 0.29 0.25 4.74 1.35 54500 3 ESR50036 900 IP54 0.85 0.69 0.49 0.23 1.5 0.56 56560 1 ESR56016 880 IP54 1.8 1.58 1.3 0.99 0.43 4.6 1.95 56560 3 ESR56036 860 IP54 1.72 1.48 1.16 0.75 0.39 1.75 0.81 56630 1 ESR63016 880 IP54 2.63 2.35 2.05 1.76 0.6 5.3 2.7 57630 3 ESR63036 890 IP54 2.66 2.39 2.07 1.78 0.59 3.6 1.3 59710 1 ESR71016 850 IP54 3.85 3.53 3.19 2.83 0.89 8 4.1 60710 3 ESR71036 860 IP54 4 3.7 3.4 3.1 2.58 1.1 7.7 2.2 62800 3 ESR80036 900 IP54 4.81 4.44 4.08 3.72 3.18 2.45 1.4 9.8 2.7 641000 3 ESR100036 935 IP54 10.88 10.34 10.04 9.73 9.34 8.92 8.45 7.87 7.26 6.72 5.5 67 10.5 778 Pole630 3 ESR63038 630 IP54 1.08 0.58 0.31 1.5 0.65 55710 3 ESR71038 630 IP54 2.69 2.27 1.66 0.43 3.3 1.1 55800 3 ESR80038 670 IP54 3.32 2.85 2.34 0.69 5 1.75 581000 3 ESR100038 670 IP54 6.78 6.34 5.91 5.42 4.66 3.63 2.2 13 4.2 65FLC = Full Load CurrentSC = Starting CurrentW: www.vent-axia.com 205


EuroSeries® (ESR)Models & AccessoriesSpeed ControllersElectronic Auto Starter OverloadFan 1ph Transfor 1ph 1 phase Stock FanStock Ref Stock Ref Stock Ref Ref Ref Stock Ref1 Phase - 2 Pole 3 Phase - 2 PoleESR25012 SP5001 SPM5020 444744 444699 ESR25032ESR31512 SP5025 SPM5035 444744 444701 ESR315321 Phase - 4 Pole 3 Phase - 4 PoleESR25014 SP5001 SPM5020 444744 444696ESR31514 SP5001 SPM5020 444744 444699 ESR31534ESR35514 SP5001 SPM5020 444744 444699 ESR35534ESR40014 SP5025 SPM5020 444744 444701 ESR40034ESR45014 SP5025 SPM5020 444744 444701 ESR45034ESR50014 SP5025 SPM5035 444744 444702 ESR50034ESR56014 SP5010 SPM5075 444744 444704 ESR56034ESR63014 SPM5140 444744 444706 ESR63034ESR71034ESR800341 Phase - 6 Pole 3 Phase - 6 PoleESR35516 SP5001 SPM5020 444744 444698 ESR35536ESR40016 SP5001 SPM5020 444744 444699 ESR40036ESR45016 SP5001 SPM5020 444744 444699 ESR45036ESR50016 SP5025 SPM5020 444744 444700 ESR50036ESR56016 SP5025 SPM5035 444744 444701 ESR56036ESR63016 SP5050 SPM5035 444744 444702 ESR63036ESR71016 SP5050 SPM5060 444744 444703 ESR71036ESR80036ESR1000363 Phase - 6 PoleESR63038ESR71038ESR80038ESR100038All red highlighted text GEN All blue highlighted text INDRoof Cowl AssemblyDrop in Curb AttenuatorONLY (No Fan) (600mm) (900mm) (1200mm)Model Ref Stock Ref Stock Ref Stock Ref Stock RefESR250 - RAZ300600 RAZ300900 -ESR315 & 355 RCZ300 RAZ300600 RAZ300900 RAZ3001200ESR400 & 450 RCZ400 RAZ400600 RAZ400900 RAZ4001200ESR500 & 560 RCZ500 RAZ500600 RAZ500900 RAZ5001200ESR630 RCZ630 RAZ600600 RAZ600900 RAZ6001200ESR710 RCZ630 RAZ600600 RAZ600900 RAZ6001200ESR800RCZ800ESR1000RCZ1000206 T: 0844 856 0590


Roof UnitsSpeed ControllersAuto Starter Adaptor UnitsTransfor 3ph 3 phase Overload Shutters Birdguard (Purlin Box)Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock RefRDTK10 444747 444699 RSZ300 BGZ300 PBZ300RDTK10 444747 444700 RSZ300 BGZ300 PBZ300RSZ300 BGZ300 PBZ300RDTK10 444747 444697 RSZ300 BGZ300 PBZ300RDTK10 444747 444698 RSZ300 BGZ300 PBZ300RDTK10 444747 444699 RSZ400 BGZ400 PBZ400RDTK10 444747 444699 RSZ400 BGZ400 PBZ400RDTK20 444747 444700 RSZ500 BGZ500 PBZ500RDTK40 444747 444701 RSZ500 BGZ500 PBZ560RDTK40 444747 444702 RSZ630 BGZ630 PBZ630RDTK70 444747 444703 RSZ630 BGZ630 PBZ710RD14 444747 444705 - INCL PBZ800RDTK10 444747 444697 RSZ300 BGZ300 PBZ300RDTK10 444747 444697 RSZ400 BGZ400 PBZ400RDTK10 444747 444697 RSZ400 BGZ400 PBZ400RDTK10 444747 444699 RSZ500 BGZ500 PBZ500RDTK10 444747 444699 RSZ500 BGZ500 PBZ560RDTK20 444747 444700 RSZ630 BGZ630 PBZ630RDTK40 444747 444702 RSZ630 BGZ630 PBZ710RDTK40 444747 444702 - INCL PBZ800RD14 444748 444706 - INCL PBZ1000RDTK10 444747 444699 RSZ630 BGZ630 PBZ630RDTK20 444747 444700 RSZ630 BGZ630 PBZ710RDTK20 444747 444701 - INCL PBZ800RDTK70 444747 444703 - INCL PBZ1000Note:- The Standard roof cowl colour is BS 00A 05 (Goose Wing Grey) for all special B.S. or RAL colours (contact <strong>Vent</strong>-<strong>Axia</strong>).- When speed control is required a 5 step auto transformer speed controller is recommended, to ensure low noise levels.- All 3 phase models are suitable for frequency inverter speed control.W: www.vent-axia.com 207


fFan BoxIn-Line Centrifugal Duct Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits Air volumes up to 1.08m 3 /s Suitable for external pressures up to 400Pa Designed to suit duct diameters from 100 to 500mm Operating Temperatures up to +40˚C Speed Controllable Quality Assurance to BS EN ISO 9001:1994 Performance tested to BS848 Part 1 1980Dimensions (mm)AIRFLOW38.3 typDAIRFLOW= =B3.0 typCAAIRFLOWØ EAnti Vibration MountingsStock ref a b c d e f g68MP033G 27 37 54 67 7 3 M8Performance Guideag ØFan Duty m 3 /s @ Pa Motor AmpsStock Ref RPM Phase 0 50 100 150 200 250 300 350 400 kW FLC SCFB100 2500 1 0.06 0.06 0.05 0.03 0.08 0.64 0.8FB125 2500 1 0.07 0.06 0.05 0.04 0.08 0.64 0.8FB150 1800 1 0.18 0.18 0.16 0.15 0.13 0.11 0.08 0.18 0.79 3.2FB160 1800 1 0.19 0.18 0.17 0.15 0.13 0.11 0.08 0.18 0.79 3.2FB200 1450 1 0.25 0.23 0.21 0.19 0.17 0.14 0.11 0.22 0.95 4.0FB250 1350 1 0.53 0.49 0.44 0.39 0.33 0.26 0.18 0.08 0.60 3.00 12.0FB315 1400 1 0.90 0.84 0.78 0.70 0.62 0.48 0.35 0.21 1.32 6.20 13.0FB400 1400 1 0.99 0.94 0.87 0.81 0.72 0.60 0.46 0.29 0.11 1.32 6.20 13.0FB500 1400 1 1.08 1.02 0.96 0.90 0.83 0.73 0.61 0.34 0.13 1.32 6.20 13.0FLC = Full Load Current SC = Starting Currente Øc ctsdbFan Stock Ref A B C D ØE KgFB100 268 363 171 272 97 13FB125 268 363 171 272 122 13FB150 322 400 203 336 147 13FB160 322 400 203 336 157 13FB200 322 400 203 336 197 18FB250 472 614 320 499 247 23FB315 530 630 300 560 312 33FB400 530 630 300 560 397 48FB500 530 630 300 560 497 72Sound Power Level Spectra dB (ref 10 -12 Watts)Fan Mid Octave Bands dBAStock Ref 63 125 250 500 1k 2k 4k 8k @3mInlet 54 62 46 46 48 47 45 39 33FB100Outlet 50 57 55 57 51 50 46 41 37Inlet 52 56 53 44 50 46 42 38 33FB125Outlet 50 56 55 54 56 47 45 41 38Inlet 59 64 54 48 42 39 38 35 32FB150Outlet 59 68 62 64 63 64 63 62 50Inlet 59 64 54 48 42 39 38 35 32FB160Outlet 59 68 62 64 63 64 63 62 50Inlet 63 68 55 59 59 57 58 54 44FB200Outlet 59 68 67 63 66 64 63 61 50Inlet 66 66 62 60 56 55 56 56 43FB250Outlet 61 68 62 62 62 60 61 61 48Inlet 71 72 66 64 65 65 62 55 50FB315Outlet 66 73 68 67 70 69 67 59 54Inlet 71 74 69 67 67 68 67 61 53FB400Outlet 66 77 71 71 74 71 71 66 58Inlet 71 73 65 67 68 68 65 58 53FB500Outlet 59 72 68 70 70 69 67 60 55208 T: 0844 856 0590


Roof UnitsModels & AccessoriesSpeed ControllerFan Electronic Auto Transfor. Starter OverloadAnti VibrationMountsStock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ TradeFB100 SP5001 SPM5020 444744 444699 68MP033GFB125 SP5001 SPM5020 444744 444699 68MP033GFB150 SP5001 SPM5020 444744 444699 68MP033GFB160 SP5001 SPM5020 444744 444699 68MP033GFB200 SP5001 SPM5020 444744 444700 68MP033GFB250 SP5050 SPM5035 444744 444702 68MP033GFB315 SP5010 SPM5075 444744 444704 68MP033GFB400 SP5010 SPM5075 444744 444704 68MP033GFB500 SP5010 SPM5075 444744 444704 68MP033GSpareFan Electric Heaters Panel Filters Panel Filters Bag Filters Spare Bag FiltersStock Ref Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ TradeFB100 - QPF100 FILTERS100 QPFB100 FILTERQPFB100FB125 QAH125 QPF125 FILTERS125160 QPFB125 FILTERQPFB125FB150 QAH150 QPF150 FILTERS125160 QPFB150 -FB160 QAH160 QPF160 FILTERS125160 QPFB160 FILTERQPFB160FB200 QAH200 QPF200 FILTERS200 QPFB200 FILTERQPFB200FB250 QAH250 QPF250 FILTERS250 QPFB250 FILTERQPFB250FB315 QAH315 QPF315 FILTERS315 QPFB315 FILTERQPFB315FB400 QAH400 QPF400 FILTERS400 QPFB400 FILTERQPFB400FB500 - QPF500 63PF665 QPFB500 63BF665In-line AttenuatorsFan 300mm 600mm 900mm 1200mm Wall TerminalStock Ref Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ TradeFB100 83010030 83010060 83010090 - - SA100/280FB125 83012030 83012060 83012090 - - SA125/280FB150 83015030 83015060 83015090 - - SA150/280FB160 83016030 83016060 83016090 - SA150/280FB200 - 83020060 83020090 83020120 SA200/280FB250 - 83025060 83025090 83025120 SA250/280FB315 - 83031060 83031090 83031120 SA315/280FB400 - - 83040090 83040120 QSA400/280FB500 - - 83050090 83050120 -All red highlighted text GEN All blue highlighted text INDW: www.vent-axia.com 209


fQuiet PackIn-Line Centrifugal Duct Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits 20mm ‘O’ Class rated acoustically treated casing, ensuring minimumduct and breakout noise levels Air volumes up to 1.08m 3 /s Suitable for external pressures up to 430Pa Designed to suit duct diameters from 100 to 500mm Operating Temperatures from 15˚C up to +40˚C Speed Controllable Quality Assurance to BS EN ISO 9001:1994 Performance tested to BS848 Part 1 1980Sound Power Level Spectra dB (ref 10 -12 Watts)Fan Mid Octave Bands dBA@Stock Ref 63 125 250 500 1k 2k 4k 8k 3mQP100BQP125BQP150BQP160BQP200BQP250BQP315BQP400BQP500BInlet 55 63 47 45 45 43 42 31 31Outlet 49 63 53 55 50 47 45 40 36Breakout 50 58 45 39 34 20 20 20 24Inlet 51 58 49 42 39 37 33 20 27Outlet 50 55 54 53 55 47 45 41 37Breakout 47 51 45 35 31 20 20 20 20Inlet 62 66 50 54 49 49 49 45 37Outlet 56 66 62 61 62 64 62 62 49Breakout 57 58 54 46 42 38 37 30 29Inlet 62 66 50 54 49 49 49 45 37Outlet 56 66 62 61 62 64 62 62 49Breakout 57 58 54 46 42 38 37 30 29Inlet 61 66 53 55 51 46 48 45 36Outlet 57 67 63 63 66 64 63 62 50Breakout 57 61 53 47 43 37 36 33 30Inlet 68 63 59 56 50 46 45 41 37Outlet 64 67 61 63 61 58 59 59 46Breakout 64 65 59 53 48 43 40 34 35Inlet 73 72 66 61 59 59 56 47 45Outlet 72 74 71 69 70 69 67 61 55Breakout 70 72 68 61 57 58 55 48 45Inlet 74 74 68 62 61 61 58 51 47Outlet 72 76 71 71 73 70 70 66 57Breakout 77 75 69 64 59 59 56 47 47Inlet 70 73 67 62 61 63 60 54 48Outlet 60 70 69 70 71 70 67 61 55Breakout 77 75 69 64 59 59 56 47 47Dimensions (mm)AIRFLOWD38.3 typ3.0 typAIRFLOW=AIRFLOWSize A B C D ØE KgQP100 268 363 171 272 97 14QP125 268 363 171 272 122 14QP150 322 400 203 336 147 14QP160 322 400 203 336 157 14QP200 322 400 203 336 197 20QP250 472 614 320 499 247 25QP315 530 630 300 560 312 35QP400 530 630 300 560 397 50QP500 530 630 263 560 497 75Anti Vibration Mountingsag ØStock ref a b c d e f g68MP033G 27 37 54 67 7 3 M8Performance GuideFan Duty m 3 /s @ Pa Motor AmpsStock Ref RPM Ph. 0 50 100 150 200 250 300 350 400 kW FLC SCQP100 2500 1 0.06 0.06 0.05 0.03 0.08 0.64 2.6QP125 2500 1 0.07 0.06 0.05 0.04 0.08 0.64 2.6QP150 1800 1 0.18 0.18 0.16 0.15 0.13 0.11 0.08 0.18 0.79 3.2QP160 1800 1 0.19 0.18 0.17 0.15 0.10 0.09 0.07 0.06 0.18 0.79 3.2QP200 1450 1 0.25 0.23 0.21 0.19 0.15 0.13 0.11 0.09 0.22 0.95 4.0QP250 1350 1 0.53 0.49 0.44 0.20 0.17 0.14 0.11 0.08 0.60 3.00 12.0QP315 1400 1 0.90 0.84 0.78 0.70 0.62 0.48 0.35 0.21 1.32 6.20 13.0QP400 1400 1 0.99 0.94 0.87 0.81 0.72 0.60 0.46 0.29 0.11 1.32 6.20 13.0QP500 1400 1 1.08 1.02 0.96 0.90 0.83 0.73 0.61 0.34 0.13 1.32 6.20 13.0FLC = Full Load Current SC = Starting CurrentBe Ø=c ctsdCAbØ E210 T: 0844 856 0590


Roof UnitsModels & AccessoriesSpeed ControllerAnti VibrationFan Electronic Auto Starter OverloadMountsStock Ref £ Trade Stock Ref £ Trade Transfor. £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ TradeQP100 SP5001 SPM5020 444744 444699 68MP033GQP125 SP5001 SPM5020 444744 444699 68MP033GQP150 SP5001 SPM5020 444744 444699 68MP033GQP160 SP5001 SPM5020 444744 444699 68MP033GQP200 SP5001 SPM5020 444744 444700 68MP033GQP250 SP5050 SPM5035 444744 444702 68MP033GQP315 SP5010 SPM5075 444744 444704 68MP033GQP400 SP5010 SPM5075 444744 444704 68MP033GQP500 SP5010 SPM5075 444744 444704 68MP033GElectric Spare Panel SpareFan Heaters Panel Filters Filters Bag Filters Bag FiltersStock Ref Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ TradeQP100 - QPF100 FILTERS100 QPFB100 FILTERQPFB100QP125 QAH125 QPF125 FILTERS125160 QPFB125 FILTERQPFB125QP150 QAH150 QPF150 FILTERS125160 QPFB150 -QP160 QAH160 QPF160 FILTERS125160 QPFB160 FILTERQPFB160QP200 QAH200 QPF200 FILTERS200 QPFB200 FILTERQPFB200QP250 QAH250 QPF250 FILTERS250 QPFB250 FILTERQPFB250QP315 QAH315 QPF315 FILTERS315 QPFB315 FILTERQPFB315QP400 QAH400 QPF400 FILTERS400 QPFB400 FILTERQPFB400QP500 - QPF500 63PF665 QPFB500 63BF665In-line AttenuatorsFan 300mm 600mm 900mm 1200mm Wall TerminalStock Ref Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ Trade Stock Ref £ TradeQP100 83010030 83010060 83010090 - - SA100/280QP125 83012030 83012060 83012090 - - SA125/280QP150 83015030 83015060 83015090 - SA150/280QP160 83016030 83016060 83016090 - SA150/280QP200 - 83020060 83020090 83020120 SA200/280QP250 - 83025060 83025090 83025120 SA250/280QP315 - 83031060 83031090 83031120 SA315/280QP400 - - - 83040090 83040120 QSA400/280QP500 - - - - 83050090 83050120 - -All red highlighted text GEN All blue highlighted text INDW: www.vent-axia.com 211


fQuiet Pack Twin FanIn-Line Twin Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits Air volumes up to 1.08m 3 /s Suitable for external pressures up to 400Pa Designed to suit duct diameters from 100 to 500mm Operating temperatures up to +40˚C Speed controllable Quality assurance to BS EN ISO 9001:1994 Performance tested to BS848 Part 1 1980Dimensions (mm)AIRFLOW38.3 typDAIRFLOW= =B3.0 typCAAIRFLOWØ ESound Power Level Spectra dB (ref 10 -12 Watts)Fan Mid Octave Bands dBA@Stock Ref 63 125 250 500 1k 2k 4k 8k 3mInlet 55 63 47 45 45 43 42 31 31QPTW100B Outlet 49 63 53 55 50 47 45 40 36Breakout 50 58 45 39 34 20 20 20 24Inlet 51 58 49 42 39 37 33 20 27QPTW125B Outlet 50 55 54 53 55 47 45 41 37Breakout 47 51 45 35 31 20 20 20 20Inlet 62 66 50 54 49 49 49 45 37QPTW150B Outlet 56 66 62 61 62 64 62 62 49Breakout 57 58 54 46 42 38 37 30 29Inlet 62 66 50 54 49 49 49 45 37QPTW160B Outlet 56 66 62 61 62 64 62 62 49Breakout 57 58 54 46 42 38 37 30 29Inlet 61 66 53 55 51 46 48 45 36QPTW200B Outlet 57 67 63 63 66 64 63 62 50Breakout 57 61 53 47 43 37 36 33 30Inlet 68 63 59 56 50 46 45 41 37QPTW250B Outlet 64 67 61 63 61 58 59 59 46Breakout 64 65 59 53 48 43 40 34 35Inlet 73 72 66 61 59 59 56 47 45QPTW315B Outlet 72 74 71 69 70 69 67 61 55Breakout 70 72 68 61 57 58 55 48 45Inlet 74 74 68 62 61 61 58 51 47QPTW400B Outlet 72 76 71 71 73 70 70 66 57Breakout 77 75 69 64 59 59 56 47 47Inlet 70 73 67 62 61 63 60 54 48QPTW500B Outlet 60 70 69 70 71 70 67 61 55Breakout 77 75 69 64 59 59 56 47 47Size A B C D ØE KgQPTW100 290 635 171 450 97 24QPTW125 290 635 171 450 122 24QPTW150 340 635 203 550 147 24QPTW160 340 635 203 550 157 24QPTW200 340 770 203 550 197 35QPTW250 495 1015 320 750 247 43QPTW315 595 1015 300 750 312 61QPTW400 595 1015 300 750 397 87QPTW500 595 1015 300 750 497 131Anti Vibration Mountingsac ctsdStock ref a b c d e f g68MP033G 27 37 54 67 7 3 M8Performance Guideg Øe ØDuty m 3 /s @ PaMotor AmpsModel RPM Ph. 0 50 100 150 200 250 300 350 400 kW FLC SCQPTW100 2500 1 0.05 0.05 0.04 0.03 0.08 0.64 2.60QPTW125 2500 1 0.06 0.06 0.05 0.04 0.08 0.64 2.60QPTW150 1800 1 0.16 0.16 0.14 0.13 0.11 0.09 0.07 0.18 0.79 3.20QPTW160 1800 1 0.17 0.16 0.15 0.13 0.12 0.10 0.07 0.18 0.79 3.20QPTW200 1450 1 0.23 0.21 0.19 0.17 0.15 0.13 0.97 0.22 0.95 4.00QPTW250 1350 1 0.46 0.42 0.38 0.34 0.29 0.22 0.16 0.07 0.60 3.00 12.00QPTW315 1400 1 0.77 0.72 0.66 0.60 0.51 0.41 0.30 0.18 0.07 1.32 6.20 13.00QPTW400 1400 1 0.90 0.85 0.80 0.73 0.65 0.54 0.42 0.26 0.10 1.32 6.20 13.00QPTW500 1400 1 1.01 0.96 0.90 0.84 0.77 0.67 0.56 0.32 0.12 1.32 6.20 13.00FLC = Full Load Current SC = Starting Currentb212 T: 0844 856 0590


Roof UnitsModels & AccessoriesSpeed ControllerACOB1A Twin Fan ControllerFanAuto ChangeoverControllerElectronic 1ph Auto TransforStock Ref Stock Ref Stock Ref Stock RefQPTW100 ACOB1A SP5001 SPM5020QPTW125 ACOB1A SP5001 SPM5020QPTW150 ACOB1A SP5001 SPM5020QPTW160 ACOB1A SP5001 SPM5020QPTW200 ACOB1A SP5001 SPM5020QPTW250 ACOB1A SP5050 SPM5035QPTW315 ACOB1A SP5010 SPM5075QPTW400 ACOB1A SP5010 SPM5075QPTW500 ACOB1A SP5010 SPM5075FanStock RefAntiVibrationMountsStock RefIntumescentFireDampersStock RefIn-line AttenuatorsFan 300mm 600mm 900mm 1200mmStock Ref Stock Ref Stock Ref Stock Ref Stock RefQPTW100 83010030 83010060 83010090 -QPTW125 83012030 83012060 83012090 -QPTW150 83015030 83015060 83015090 -QPTW160 83016060 83016090 -QPTW200 - 83020060 83020090 83020120QPTW250 - 83025060 83025090 83025120QPTW315 - 83031060 83031090 83031120QPTW400 - - 83040090 83040120QPTW500 - - 83050090 83050120FusibleLink FireDamperStock RefWallTerminalStock RefRoofTerminalStock RefQPTW100 68MP033G CVT100 PA100 SA100/280 WRC100QPTW125 68MP033G CVT130 PA125 SA125/280 WB160QPTW150 68MP033G CVT150 - SA150/280 WB160QPTW160 68MP033G - PA160 SA150/280 WB200QPTW200 68MP033G CVT200 PA200 SA200/280 WB200QPTW250 68MP033G CVT250 - SA250/280 WB200QPTW315 68MP033G CVT300 - SA315/280 RCZ300QPTW400 68MP033G - - QSA400/280 RCZ400QPTW500 68MP033G - - - RCZ500Features & Benefits Manual or auto changeover facilities 2 to 24 hour adjustable duty sharing Diagnostic program facility on start up Suitable for 1 phase twin fan units up to8 amps Can be wired in conjunction with speedcontrollers Volt free contacts fitted as standard Failure neon indicatorsSpecificationSupply Voltage: 230 to 240V/1ph/50Hz.Maximum Current Capacity: 0.1 to 8.0 amps.Operating temperature: 0˚C to -+40˚C.IP rating: IP40.Fuse Size: T rated 15 amp glass fuse (5x20mm).ModelsStock RefACOB1ADimensions (mm)size ØA ØB KgACOB1A 125 56 0.28GENABGENAINDW: www.vent-axia.com 213from <strong>Vent</strong>-<strong>Axia</strong>


Slimpak® (SLP)In-Line Centrifugal Duct Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits Ultra slim and compact Acoustically treated “O” class rated ‘Eco Flow’ computer modelled design Latest external rotor motor Fully speed controllable Matching ancillariesDimensions (mm)WAIRFLOWAIRFLOWDØXMounting bracket (mm)12mm x 6mmFoam GasketAPlan15LPlanC ctsC ctsBHDØ6 Holes ¯ 5.5mmElevationElevationFanStock Ref L W H DØ XWeightkgSLP100 360 306 160 100 178 8SLP125 360 306 160 125 165 8SLP150 360 306 180 150 140 9SLP200 415 360 285 200 140 13SLP250 415 360 285 250 90 15SLP315 450 400 350 315 65 17FanStock RefA B CSLP100 306 80 138SLP125 306 80 138SLP150 306 80 138SLP200 360 130 165SLP250 360 130 165SLP315 400 180 184.5Performance GuideFan Duty m 3 /s @ Pa AmpsStock Ref RPM Phase 0 25 50 100 150 200 250 300 350 400 450 500 550 kW FLC SCSLP100 2450 1 0.075 0.071 0.068 0.059 0.051 0.041 0.029 0.016 - - - - - 0.058 0.26 1.04SLP125 2450 1 0.094 0.090 0.086 0.076 0.065 0.053 0.040 0.025 - - - - - 0.058 0.26 1.04SLP150 2450 1 0.121 0.116 0.112 0.098 0.085 0.0.70 0.054 0.038 0.016 - - - - 0.058 0.26 1.04SLP200 2700 1 0.200 0.193 0.188 0.175 0.156 0.138 0.118 0.098 0.073 0.12 0.48 1.92SLP250 2400 1 0.289 0.280 0.271 0.251 0.227 0.201 0.175 0.146 0.117 0.088 0.053 0.21 0.90 3.60SLP315 2550 1 0.380 0.342 0.370 0.350 0.328 0.309 0.290 0.271 0.248 0.220 0.185 0.141 0.079 0.27 1.15 4.60FLC = Full Load Current SC = Starting Current214 T: 0844 856 0590


Roof UnitsModels & AccessoriesSpeed ControllerFan Electronic Auto Transfor. Starter Overload Electric HeatersStock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock RefSLP100 SP5001 SPM5020 444744 444699 -SLP125 SP5001 SPM5020 444744 444699 QAH125SLP150 SP5001 SPM5020 444744 444699 QAH150SLP200 SP5001 SPM5020 444744 444699 QAH200SLP250 SP5001 SPM5020 444744 444700 QAH250SLP315 SP5001 SPM5020 444744 444702 QAH315In-line AttenuatorsFan 300mm 600mm 900mm 1200mm Wall TerminalStock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock RefSLP100 SLSI100/1 SLSI100/2 SLSD100/1 SLSD100/2 SA100/280SLP125 SLSI125/1 SLSI125/2 SLSD125/1 SLSD125/2 SA125/280SLP150 SLSI150/1 SLSI150/2 SLSD150/1 SLSD150/2 SA150/280SLP200 SLSI200/1 SLSI200/2 SLSD200/1 SLSD200/2 SA200/280SLP250 SLSI250/1 SLSI250/2 SLSD250/1 SLSD250/2 SA250/280SLP315 SLSI315/1 SLSI315/2 SLSD315/1 SLSD315/2 SA315/280Louvre Flexible Spare Panel Back DraughtFan Roof Terminal Shutter Connections Panel Filters Filters ShuttersStock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock RefSLP100 WRC100 LS250 FLX100 SLPF100 FILTERSSLP100 BDS100SLP125 WB160 LS250 FLX125 SLPF125 - BDS125SLP150 WB160 LS315 FLX150 SLPF150 FILTERSSLP150 BDS150SLP200 WB200 LS315 FLX200 SLPF200 FILTERSSLP200 BDS200SLP250 WB200 LS315 FLX250 SLPF250 FILTERSSLP250 BDS250SLP315 RCZ300 LS400 FLX315 SLPF315 FILTERSSLP315 BDS315All red highlighted text GEN All blue highlighted text INDW: www.vent-axia.com 215


Slimpak® (SLPT)In-Line Twin Duct Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits Motor Insulation Class B, protectedto IP44 All units suitable for speed control Quality Assurance to BS EN ISO9001:1994 Performance tested to BS848 Part 1 1980 Units suitable as a run & standby extractfan or simultaneously running fanDimensions (mm)AIRFLOWLDØWXPlan8 holes 8mm ØHElevationUnitWeightDuctØ L W H DØ X kg200 760 490 235 200 205 20250 865 590 285 250 233 32315 955 650 350 315 240 39Performance GuideFan Duty m 3 /s @ Pa AmpsStock Ref RPM Phase 0 25 50 100 150 200 250 300 350 400 450 500 550 kW FLC SC2 Pole Run & Stanby Perfomance GuideSLPT200 2450 1 0.11 0.10 0.10 0.08 0.07 0.05 0.03 0.01 - - - - - 0.09 0.36 1.44SLPT250 2400 1 0.26 0.25 0.024 0.22 020 0.18 0.16 0.14 0.11 0.09 0.04 - - 0.21 0.90 3.60SLPT315 2550 1 0.40 0.38 0.37 0.35 0.33 0.31 0.29 0.27 0.25 0.22 0.18 0.14 0.07 0.27 1.15 4.602 Pole Simultaneously Running Performance GuideSLPT200 2450 1 0.21 0.20 0.19 0.17 0.15 0.12 0.09 0.06 0.19 0.72 2.88SLPT250 2450 1 0.46 0.44 0.43 0.41 0.39 0.37 0.34 0.31 0.27 0.22 0.13 0.42 1.80 7.20SLPT315 2450 1 0.62 0.60 0.58 0.54 0.51 0.47 0.43 0.40 0.36 0.32 0.27 0.21 0.12 0.54 2.30 9.20FLC = Full Load Current SC = Starting Current216 T: 0844 856 0590


Roof UnitsModels & AccessoriesITC Man/Auto ITC-DS12/24hr RVC ELVFan Changeover controller Auto changeover controller Remote visual Indicator Auto TransformerStock Ref Stock Ref Stock Ref Stock Ref Stock RefSLPT200 10314200 10314210 10314220 10314103SLPT250 10314200 10314210 10314220 10314103SLPT315 10314200 10314210 10314220 10314103Electronic SpeedAuto TransformerFlexibleAnti-VibrationController& Coil Starter OverloadConnectionMountsSize Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref200mm W10303103M 10314103 444744 444698 FLX200 10523033250mm W10303103M 10314103 444744 444700 FLX250 10523033315mm W10303103M 10314103 444744 444700 FLX315 10523033Heat Exchange Unit Backdraught Shutter Fast ClampAluminiumFlexible Ducting (10m)Worm Drive ClipsSize Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref £Trade10538290 - - - -200mm +10577315 10542200 10540200 10539200 561710+10578315 - - - -250mm315mm10538290 - - - -+10577315 10542250 10540250 10539250 561710+10578315 - - - -10538290 - - - -+10577315 10542315 10540315 10539315 561710Pre Filter Cassette 5 Spare Pre Filters Bag Filter Cassette Spare Bag Filter Each 3-Way Splitter Duct Air HeaterSize Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref200mm 10532200 10556200 10533200 10557200 10551250 QAH200250mm 10532250 10556250 10533250 10557250 10551250 QAH250315mm 10532315 10556315 10533315 10557315 10553400 QAH315Duct Attenuator600mm 900mm 1200mm Joining Piece Lourve ShutterSize Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref200mm 10535200 10536200 10537200 561808 LS200250mm 10535250 10536250 10537250 561810 LS250315mm 10535315 10536315 10537315 561813 LS315All red highlighted text GEN All blue highlighted text INDW: www.vent-axia.com 217


EuroSeries® (SDX)In-Line Centrifugal Duct Fansfrom <strong>Vent</strong>-<strong>Axia</strong>Features & Benefits Available in sizes 100 to 315 150 to 315 available in standard orhigh performance Motor Insulation Class B, protectedto IP44 Operating temperatures from -15°C upto +40°C HOT SPOT Protection All units suitable for speed control Quality Assurance to BS EN ISO9001:1994 Performance tested to BS848 Part 1 1980Dimensions (mm)UnitWeightsize AØ BØ C D E F G H kgSDX100 100 237 204 25 25 42 270 294 3.5SDX125 125 237 193 25 25 42 270 294 3.8SDX150 150 278 195 25 25 42 312 350 3.6SDX200 200 333 210 25 25 42 374 402 5.1SDX250 250 333 210 28.6 28.5 42 380 430 4.9SDX315 315 402 265 25 30 42 450 485 7.8Performance Guidem 3 /s @ Pa Motor S.C. F.L.C dB(A)Model RPM Phase 0 50 100 150 200 250 300 350 400 450 500 Watts Amps Amps @ 3mStandard rangeSDX100B 2385 1 0.055 0.048 0.041 0.034 0.026 0.017 0.009 46 0.31 0.18 42SDX125B 2625 1 0.077 0.066 0.053 0.039 0.027 0.015 0.002 69 0.42 0.28 45SDX150B 2350 1 0.11 0.098 0.075 0.059 0.046 0.031 0.01 56 0.37 0.22 44SDX200B 2325 1 0.247 0.217 0.181 0.149 0.126 0.104 0.09 0.074 0.057 0.04 0.026 162 1.1 0.68 47SDX250B 2575 1 0.265 0.259 0.25 0.208 0.175 0.15 0.13 0.107 0.088 0.064 0.041 150 1.2 0.66 52SDX315B 2518 1 0.333 0.306 0.278 0.244 0.204 0.17 0.139 0.11 0.08 0.056 0.033 162 1.27 0.68 58High Performance RangeSDX150HB 2600 1 0.129 0.115 0.099 0.082 0.064 0.044 0.018 65 0.46 0.27 47SDX200HB 2575 1 0.26 0.24 0.22 0.192 0.166 0.142 0.116 0.095 0.072 0.05 0.03 165 1.2 0.7 54SDX250HB 2520 1 0.295 0.268 0.24 0.21 0.183 0.155 0.125 0.098 0.074 0.05 0.027 175 1.2 0.73 52SDX315HB 2574 1 0.435 0.405 0.369 0.32 0.277 0.23 0.196 0.158 0.132 0.108 0.08 278 1.7 1.15 60218 T: 0844 856 0590


Roof UnitsModels & AccessoriesFan High Performance Fan Speed Controller Starter OverloadStock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock RefSDX100 - SP5001 SPM5020 444744 444698SDX125 - SP5001 SPM5020 444744 444698SDX150 SDX150HB SP5001 SPM5020 444744 444698SDX200 SDX200HB SP5001 SPM5020 444744 444698SDX250 SDX250HB SP5001 SPM5020 444744 444699SDX315 SDX315HB SP5001 SPM5020 444744 444700In-Line AttenuatorsFan 300mm 600mm 900mm 1200mmStock Ref Stock Ref Stock Ref Stock Ref Stock RefSDX100 83010030 83010060 83010090 -SDX125 83012030 83012060 83012090 -SDX150 83015030 83015060 83015090 -SDX200 - 83020060 83020090 83020120SDX250 - 83025060 83025090 83025120SDX315 - 83031060 83031090 83031120Fan Wall Terminal Electric Heaters Panel Filters Bag FiltersStock Ref Stock Ref Stock Ref Stock Ref Stock RefSDX100 SA100/280 QAH100 QPF100 QPFB100SDX125 SA125/280 QAH125 QPF125 QPFB125SDX150 SA150/280 QAH150 QPF150 QPFB150SDX200 SA200/280 QAH200 QPF200 QPFB200SDX250 SA250/280 QAH250 QPF250 QPFB250SDX315 SA315/280 QAH315 QPF315 QPFB315Fan Spare Bag Filters Roof Terminal Louvre ShutterStock Ref Stock Ref Stock Ref Stock RefSDX100 FILTERQPFB100 WRC100 LS250SDX125 FILTERQPFB125 WB160 LS250SDX150 - WB160 LS315SDX200 FILTERQPFB200 WB200 LS315SDX250 FILTERQPFB250 WB200 LS315SDX315 FILTERQPFB315 RCZ300 LS400All red highlighted text GEN All blue highlighted text INDW: www.vent-axia.com 219


Speed ControllersSingle Phase SP & SPTK (Electronic)Single Phase SPM (Auto-Transformer)Features & Benefits Single Phase, electronic, infinitely variable, stepless speed controlwith MIN/MAX preset facility Separate starter not required when used with HOT SPOT protectedfan (SPTK only) Compact and easy to install Suitable for surface or flush mounting (SP5010 surface only)* SP type include ON/OFF switch with neon indicator SPTK type include ON/OFF/RESET switch and indication light fantrip indicator and built in facility for manual reset Complies with required statutory regulations and carries CE markUnit *Max Peak Dimensions WeightStock Ref Load Current H x W x D (mm) kg EnclosureSP5001 1.7 amps 86 x 86 x 71 0.33 IP40SP5025 3.0 amps 147 x 86.5 x 62 0.5 IP40SP5050 5.0 amps 147 x 86.5 x 62 0.6 IP40SPTK5050 5.0 amps 147 x 86.5 x 62 0.8 IP40SP5010 10.0 amps 185 x 172 x 135 2.0 IP54* Note:- The max peak load current is for surface mounting installation.GENStock Ref£ TradeSP5001 50.98SP5025 65.61SP5050 78.27SPTK5050 124.80SP5010 223.87Features & Benefits Single Phase, 5 step auto-transformer speed controller Low motor noise - no magnetic hum ON/OFF SwitchUnit Max Peak Dimensions Weight DamperStock Ref Load Current H x W x D (mm) kg Enclosure ConnectionSPM5020 2.0 230 x 168 x 118 2.2 IP54 YesSPM5035 3.5 230 x 168 x 118 4.6 IP54 YesSPM5060 6.0 230 x 166 x 118 5.0 IP50 YesSPM5075 7.5 284 x 240 x 132 6.2 IP54 YesSPM5090 9.0 316 x 270 x 168 10.5 IP54 NoSPM5140 14.0 316 x 270 x 168 16.5 IP54 NoGENStock Ref£TradeSPM5020 124.80SPM5035 124.80SPM5060 168.15SPM5075 190.69SPM5090 211.48SPM5140 318.52220 T: 0844 856 0590


Roof UnitsSingle Phase RTRE (Enhanced Auto-Transformer)Three Phase RDTK (Auto - Transformer)Features & Benefits Single Phase 5 step auto-transformer speed controller Separate starter not required when used with HOT SPOTprotected fans Low motor noise - no magnetic hum Additional terminals to allow connection of remoteswitching device Allows operation via BMS interface Additional terminals to allow connection of remoteanti-freezing thermostatFeatures & Benefits Three phase 5 step auto - transformer speed controller Separate starter not required when used with HOT SPOTprotected fans Low motor noise - no magnetic hum Compact fire retardant surface mounting enclosure Additional terminals to allow connection of remoteswitching device Additional terminals to allow connection of remoteanti-freezing thermostatUnit Max Peak Dimensions Weight DamperStock Ref Load Current H x W x D (mm) kg IP Connection VFCRTRE20 2.0 amps 230 x 166 x 118 2.3 IP54 Yes YesRTRE35 3.5 amps 230 x 166 x 118 3.6 IP54 Yes YesRTRE60 6.0 amps 230 x 166 x 118 5.1 IP54 Yes YesRTRE75 7.5 amps 284 x 240 x 132 6.1 IP54 Yes YesRTRE90 9.0 amps 284 x 240 x 132 10.6 IP54 Yes YesGENStock Ref£ TradeRTRE20 164.12RTRE35 187.47RTRE60 196.58RTRE75 254.82RTRE90 283.28Unit Max Peak Dimensions Weight DamperStock Ref Load Current H x W x D (mm) kg Enclosure ConnectionRDTK10 1.0 amps 284 x 240 x 132 4.7 IP54 YesRDTK20 2.0 amps 284 x 240 x 132 7.4 IP54 YesRDTK40 4.0 amps 316 x 270 x 168 12.9 IP21 NoRDTK70 7.0 amps 324 x 270 x 168 15.6 IP21 YesRD14 14.0 amps 295 x 400 x 170 30.0 IP21 NoGENStock Ref£ TradeRDTK10 206.24RDTK20 239.96RDTK40 335.59RDTK70 407.71RD14 764.86W: www.vent-axia.com 221


Roof UnitsStarters &OverloadsStartersSuitable for all models. Push button Start/Stop.240V contactor coil for single phase applicationsand three phase supplies where a neutral is present.415V contactor coil for three phase supplies wherea neutral is not present or required.Protection is given by an overload relay which isselected to match the load of the fan. Enclosuresare protected to IP55.New DOL Rating Star Delta Dimensions WeightStock Ref Starters (Amps) Rating (Amps) HXWXD Kg444744 DOL Starter 1 Phase 240V 12A 12 - 174x104x134 3.0444745 DOL Starter 1 Phase 240V 25A 25 - 174x104x134 1.5444746 DOL Starter 1 Phase 240V 32A 32 - 184x184x149 2.5444747 DOL Starter 3 Phase 415V 12A 12 - 174x104x134 3.0444748 DOL Starter 3 Phase 415V 25A 25 - 174x104x134 3.5444749 DOL Starter 3 Phase 415V 32A 32 - 184x184x149 2.5444750 DOL Starter 3 Phase 415 V 50A 50 - 305x285x159 7.0444842 Star Delta Starter 21A n/a 21 184x284x149 3.5444843 Star Delta Starter 30A n/a 30 184x284x149 3.5New DOL Rating Star Delta GENStock Ref Overloads (Amps) Rating (Amps)444696 OVERLOAD 0.16-0.25 0.16-0.25 -444697 OVERLOAD 0.25-0.40 0.25-0.40 -444698 OVERLOAD 0.40-0.63 0.40-0.63 -444699 OVERLOAD 0.63-1.0 0.63-1.0 -444700 OVERLOAD 1.0-1-6 1.0-1-6 -444701 OVERLOAD 1.6-2.5 1.6-2.5 2.7-4.3444702 OVERLOAD 2.5-4.0 2.5-4.0 4.3-6.9444703 OVERLOAD 4-0.6.0 4-0.6.0 6.9-10444704 OVERLOAD 5.5-8.0 5.5-8.0 9.5-13.8444705 OVERLOAD 7-10 7-10 12-17444706 OVERLOAD 10-13 10-13 17-22444707 OVERLOAD 13-18 13-18 22-31444708 OVERLOAD 18-25 18-25 31-43444709 OVERLOAD 23-32A 23-32A 39-55This new range of Starters and Overloads is not cross compatible with previous versions222 T: 0844 856 0590


Roof UnitsSonexCircular Sound AttenuatorsFeatures & Benefits Low cost – exceptional performance,exstock availability Sheet steel casing and end plates 30minute fire rating as standard Fitted spigot for direct connection tocircular ductworkApplication DataThe effective and economic solution for soundattenuation in circular duct systems from 100 to500mm diameter. With at least three models persize throughout the range the system designer isgiven complete flexibility of choice allowing aselection which is the best balance of attenuation,size and cost for any application. Sonex Attenuatorsare fitted with a patented duct seal which enablesleak free ‘plug-in’ connection to rigid ductworkwith consequent savings of installation costs. Theexcellent attenuation characteristics of the Sonexrange are achieved without imposing undue systemresistance. Pressure losses are little more than thosewhich would occur over a comparable section ofstraight duct.ConstructionThe attenuator consists of a perforated tubular linermanufactured from sheet steel. The liner is enclosedby a thick layer of mineral wool sound absorbingmaterial. Casing and end plates are formed fromgalvanised sheet steel. Standard models have a 30minute fire rating (60 minutes also available).Dimensions, Weights & Insertion LossDimensions (mm) Attenuation dB mid Frequency HzStock Ref dØ DØ L kg. 63 125 250 500 1K 2K 4K 8k83010030 100 200 300 2.4 3 3 9 17 23 26 25 1383010060 100 200 600 4.1 6 9 15 34 40 40 37 1883010090 100 200 900 6.6 10 13 21 40 45 39 36 1683012030 125 225 300 2.6 3 3 7 16 20 24 22 1783012060 125 225 600 4.5 5 8 13 29 35 35 32 2283012090 125 225 900 7.6 10 12 19 37 40 38 34 3283015030 150 260 300 2.9 3 3 6 13 19 23 22 1683015060 150 260 600 5.8 5 7 12 24 30 35 31 2083015090 150 260 900 9 8 10 15 32 38 37 34 2983016030 160 260 300 2.9 3 3 6 13 19 23 22 1683016060 160 260 600 5.8 5 7 12 24 30 35 31 2083016090 160 260 900 9 8 10 15 32 38 37 34 2983020060 200 300 600 7 4 6 10 20 27 33 19 1783020090 200 300 900 10 8 9 14 28 32 35 28 2583020120 200 300 1200 14 10 12 17 36 41 43 28 2683025060 250 355 600 8.6 4 5 10 19 25 29 18 1783025090 250 355 900 12.2 6 7 12 23 30 30 22 1983025120 250 355 1200 18 8 10 15 32 37 38 26 2083031060 315 400 600 9.8 4 5 8 15 20 22 17 1583031090 315 400 900 15 5 7 10 20 30 29 18 1683031120 315 400 1200 21 7 9 13 22 32 33 19 1883040090 400 606 900 21 3 5 9 19 26 20 13 1183040120 400 606 1200 27 6 8 14 2 4 30 28 17 983050090 500 711 900 29 3 4 9 15 23 17 12 1183050120 500 711 1200 38 5 7 13 18 26 23 15 9W: www.vent-axia.com 223


Roof UnitsPyrocheckIntumescent FireDampersFeatures & Benefits Suitable for air transfer in doors andpartitions Complete seal achieved in approximatelyfive minutes when tested in accordancewith BS 476 pt 20 & 22 Available in circular form UV Stabilised material UPVC Pyrocheck offer much lower resistance toairflow compared to traditional designs Independently tested to BS 476 pt. 22; fireintegrity of 68 minsPyrocheck CVT Intumescent Fire Dampers areavailable in circular form and have a minimumfire integrity of one hour (in accordance withBS476 Part 8 1972). The fire dampers havebeen independently tested at the Warrington FireResearch Centre.Intumescent fire dampers require no mechanicalor external/device to operate as they rely solelyon an internal reaction initiated by heat. They are,therefore, especially suitable for applications whereregular inspection is unlikely or difficult or wheremechanical devices would be susceptible to shockor corrosion damage.Typical applications are air transfer in fire doors orpartitions.The active material is encased in a PVC sleevegiving maximum protection against moulds, fungi,insect attack or similar biological damage, andmay reasonably be expected to last for the lifeof the building. Unaffected by UV light, capableof withstanding freeze/thaw cycling and ableto support ambient temperatures within the range-10°C to +80°C.In a fire situation Pyrocheck CVT Dampers willrapidly expand to completely block the duct oropening thus preventing the further passage ofsmoke and hot gasses.An unusually high free area means that PyrocheckCVT Dampers offer much lower resistance to airflow compared to traditional intumescent designs.ModelsGENSize Stock Ref £ Trade4” Ø CVT100 47.325” Ø CVT130 54.606” Ø CVT150 61.898” Ø CVT200 70.9810” Ø CVT250 80.1012” Ø CVT300 96.47A full variation on sizes available on request. MatchingTransfer Grilles available.DimensionsStock RefDØCVT100 100CVT130 125CVT150 150CVT200 198CVT250 248CVT300 298<strong>Vent</strong>-<strong>Axia</strong> does not guarantee compliance with Building Regulations Part B, Fire Spread or other regulations that relate to fire planning. Suitabilityto comply with these regulations should be determined prior to installation and in conjunction with Building Control Officers. Compliance with theRegulations is specifically excluded from quotations and designs.224 T: 0844 856 0590


Roof UnitsPyrocheckFusible Link Fire DampersFeatures & Benefits Suitable for horizontal airflow, throughwall mounting Four hour tested to BS476 Part 20 High shut-off twin blade design Low cost solution for small diameter ducts Complete with gasket for in-duct mounting Low pressure drop and noise generation Blade locking springsPyrocheck Series PA fire dampers can bemounted horizontally, vertically without effect ontheir operation.The design of Pyrocheck Series PA presents minimalobstruction to the air flow during normal operation(prior to initiation), consequently the pressure dropacross the damper is extremely low.The precision low mass fusible link is set to operateat 72°C. Operation of the fusible link releases theblades and completely blocks the duct. A featureof the PA damper is its duct sealing ring andintumescent seal. This compensates for any minorirregularities in the duct which may otherwise creategaps between the duct wall and the damper.ModelsGENDuct Size Stock Ref £ Trade100mm Ø PA100 42.21125mm Ø PA125 56.92160mm Ø PA160 67.09200mm Ø PA200 73.06DimensionsBCAØStock Ref AØ B CPA100 99 72.5 72.5PA125 124 72.5 85PA160 159 72.5 103PA200 199 72.5 121Fire RatingThe pyrocheck range of dampers have been testedat Warrington Fire Research Centre. The damperswere assessed against the criterion for integrity asdefined in BS476 Part 20 for 4 hours.The dampers maintained their integrity successfullythroughout the test, which was discontinued after4 hours.<strong>Vent</strong>-<strong>Axia</strong> does not guarantee compliance with Building Regulations Part B, Fire Spread or other regulations that relate to fire planning. Suitabilityto comply with these regulations should be determined prior to installation and in conjunction with Building Control Officers. Compliance with theRegulations is specifically excluded from quotations and designs.W: www.vent-axia.com 225


Roof Units<strong>Vent</strong>ilexFire Protection<strong>Vent</strong>ilation ValvesFeatures & Benefits Supply and extract valve Integrated 2 hour fire damper 74˚ thermal fuse Tested to BS476 Part 20 White epoxy finished steel Adjustable centre core<strong>Vent</strong>ilex Model VHD extract/supply valves offer allthe advantages long associated with the <strong>Vent</strong>ilexrange, with one very special addition.Model VHD is also an integrated, 2 hourrated fire damper. The unit operates asa supply/exhaust valve in normal circumstances butis equipped with a thermal fuse and rapid closurespring. lts careful design allows full adjustment overa wide range of pressure/flow settings. When thetemperature rises above 74°C the thermal fusereleases the closure mechanism. In this closedposition the valve has been tested in accordancewith BS476 Part 20 and is independently verifiedas having a 2 hour rating.The whole assembly has an epoxy white finish andis constructed from steel. The valve installs into afixing frame allowing simple connection to ductworkand easy access for adjustment or cleaning.ModelGENDuct Size Stock Ref £ Trade100mm Ø VHD100 47.32125mm Ø VHD125 48.02150mm Ø VHD150 56.79200mm Ø VHD200 66.24Dimensions (mm)Stock Ref AØ BØVHD 100 140 99VHD 150* 200 150**125mm and 200mm to special requestThe central core is adjustable and offers a widerange of setting to meet specific system designs.Datum position is achieved when core face is levelwith face of valve (see diagram below).ApplicationsBathrooms, kitchens, toilets and lobby areasrequiring an efficient adjustable diffuser with integralfire protection.<strong>Vent</strong>-<strong>Axia</strong> does not guarantee compliance with Building Regulations Part B, Fire Spread or other regulations that relate to fire planning. Suitabilityto comply with these regulations should be determined prior to installation and in conjunction with Building Control Officers. Compliance with theRegulations is specifically excluded from quotations and designs.226 T: 0844 856 0590


Roof Units<strong>Vent</strong>ilexSteel <strong>Vent</strong>ilation ValvesFeatures & Benefits Supply and extract valve White epoxy finished steel Adjustable centre core Bayonet fixing - easy removal for cleaningDimensions (mm)<strong>Vent</strong>ilex Model VHE extract/supply valvesare a new addition to the well established<strong>Vent</strong>ilex range and continue the conceptof elegant design combined with excellentperformance characteristics.The valves are constructed from white epoxyfinished steel and are supplied complete with abayonet action fixing frame.This allows positive locking and sealing of the valveyet still enables, easy removal for adjustment orcleaning. The valve profile is designed to eliminatefouling of adjacent decorated surfaces - a featurecommon to all <strong>Vent</strong>ilex valves.Stock Ref AØ BØVHE 100 140 99VHE 150* 200 150**125mm and 200mm to special requestThe central core is adjustable and offers a widerange of settings to meet specific system designs.Datum position is achieved when core face is levelwith face of valve (see dimensional diagram).ApplicationsBathrooms, kitchens, toilets, lobby areas or anyroom requiring a single diffuser for up to 100m 3 /hr(multiple arrays can of course be utilised).ModelsGENDuct Size Stock Ref £ Trade100mm Ø VHE100 13.03125mm Ø VHE125 14.74150mm Ø VHE150 21.32200mm Ø VHE200 25.50W: www.vent-axia.com 227


Roof UnitsUnitexRoof Cowl SystemFeatures & Benefits Complete weather proofing with lowpressure drop Supplied complete with bird guard Galvanised steel construction additionallyprotected by a dark brown epoxy powdercoat finish Weather apron in stock 3 lead Suitable for flat or pitched roofs up to20°as standard Can be supplied in special colours tomatch building designThe Unitex Roof Cowl System greatly simplifiesthe roof termination of mechanical ventilationsystems. Consisting of an attractive epoxyfinished cowl with a lead weather slate and arange of direct connection reducing fittings. Itis suitable for connection to spiral duct, soil pipeand flexible duct from 125 to 250mm diameter.<strong>Product</strong> RangeCowl AssemblyWB160 For ducts from125 to 160mmWB200 For ducts from200 to 250mmWeather Apron for Flat RoofsWA160WA200Weather Apron for PitchedRoofs (20° MAX)WA160/20WA200/20Adaptor370304 (125 to 150mm)370309 (200 to 250mm)Installation with an AdaptorCOWLSEALANTADAPTORDUCTINGCOWLSEALANTADAPTORDUCTINGDUCTING SECTION(SUPPLIED BY OTHERS)APRONWB160 with 125mm connectionUsing adaptor 370304DUCTING SECTION(SUPPLIED BY OTHERS)APRONWB200 with 250mm connectionUsing adaptor 370309ModelsDescription Stock Ref £ Trade100mm (4”) Roof SystemPVC Roof Cowl WRC100 25.76Weather Apron WA100 36.27(flat roofs)125mm to 160mm Roof SystemRoof Cowl WB160 79.38- Standard Colour BSO8B29Roof Cowl WB160C 107.09- Non-standard ColourWeather Apron WA160 52.60(flat roofs)200mm to 250mm Roof SystemRoof Cowl WB200 84.58- Standard Colour BSO8B29Roof Cowl WB200C 112.29- Non-standard ColourWeather Apron WA200 61.70(flat roofs)Weather Apron for pitched roofWeather Apron WA160/20 56.0720˚ (max) pitch roofWeather Apron WA200/20 61.5620˚ (max) pitch roofAdaptorOR16012 370304 15.00(125 to 150mm)OR25020 370309 25.00(200 to 250mm)All red highlighted textGENAll blue highlighted text IND228 T: 0844 856 0590


Roof UnitsUnitexWall TerminalsFeatures & Benefits External weather louvre, wall sleeve andduct connection spigot in one unit Satin anodised louvre gives full weatherprotection Epoxy powder coated finish, weatherlouvre available as optional extra 280mm or 80mm wall sleeve section Spigot connections from 100mm to400mmThe Unitex SA Wall Terminal Module consists ofa high grade satin anodised weather louvre fittedwith bird guard (epoxy finish optional extra). This islocated in a galvanised sheet metal ‘box section‘linked to a reinforced circular stub for directconnection to rigid or flexible ductwork.Two lengths of ‘box section’ are available; 80mmand 280mm. An airstream operated back draughtshutter can be fitted in the 280mm version. Forapplications where larger air volumes are involvedthe Unitex QSA range of wall terminals is available.Note:Volume Control Dampers, Speed Clamps &Backdraught Shutters available see AccessoriesSection.Dimensions (mm)*Dimensions F select from 280 or 80mmModel Ref A B C D EØSA100 180 180 80 130 99SA125 210 210 80 160 124SA150 230 230 80 180 149SA200 280 280 80 230 199SA250 330 330 80 280 249SA315 400 400 80 350 313QSA100 230 230 80 180 98QSA125 280 280 80 230 124QSA150 330 330 80 280 149QSA200 400 400 80 350 199QSA250 500 500 80 450 249QSA315 550 550 80 500 313QSA400 550 550 80 500 400ModelsGENDescription Stock Ref £ Trade80mm wall sleeve, std. format louvre100mm SA100/80 41.66125mm SA125/80 44.72150mm SA150/80 50.07200mm SA200/80 63.27250mm SA250/80 69.70315mm SA315/80 77.6580mm wall sleeve, large format louvre125mm QSA125/80 61.43200mm QSA200/80 80.74250mm QSA250/80 94.08315mm QSA315/80 110.12280mm wall sleeve, std. format louvre100mm SA100/280 48.22125mm SA125/280 51.17150mm SA150/280 56.71200mm SA200/280 69.64250mm SA250/280 76.79315mm SA315/280 87.23280mm wall sleeve, large format louvre100mm QSA100/280 54.07125mm QSA125/280 66.24150mm QSA150/280 82.30200mm QSA200/280 82.56250mm QSA250/280 100.24315mm QSA315/280 111.12400mm QSA400/280 115.96W: www.vent-axia.com 229


Stock Reference IndexStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page120801 Genova Cooker Hood - Silver 48120811 Napoli Cooker Hood - White 48120841 Milano Cooker Hood - Silver 48120851 Roma Cooker Hood - Silver 48131310 Traditional Standard Window 6” Model 139131420 Traditional Standard Roof 6” Model 140131510 Traditional Standard Wall 6” Model 141131610 Traditional Standard Panel 6” Model 142132310 Traditional Standard Window 7” Model 139132410 Traditional Standard Roof 7” Model 140132510 Traditional Standard Wall 7” Model 141132610 Traditional Standard Panel 7” Model 142133310 Traditional Standard Window 9” Model 139133410 Traditional Standard Roof 9” Model 140133510 Traditional Standard Wall 9” Model 141133610 Traditional Standard Panel 9” Model 142134310 Traditional Standard Window 12” Model 139134410 Traditional Standard Roof 12” Model 140134510 Traditional Standard Wall 12” Model 141134610 Traditional Standard Panel 12” Model 142140120 VA140/150KP (Pullcord) 40140220 VA140/150KT (Timer) 40140320 VA140/150KHP (Humidistat) 40140420 VA140/150KHT (Humidistat/Timer) 40140901 Window Fitting Kit white 119140902 Wall Fitting Kit white 119140903 Wall Fitting Kit brown 119152110 VA150P 41153110 VA150A 41165510 ST355-16-WL 138165620 STGF355 138165710 STX355 138165810 STARX355 138165910 STAR355 138166510 ST400-16-WL 138166620 STGF400 138166710 STX400 138167510 ST450-16-WL 138167710 STX450 138167810 STARX450 138167910 STAR450 138168510 ST500-16-WL 138168710 STX500 138180010 Remote Indicator 45180510 Duet Surface 45180610 Duet Recessed 45180710 Duet Duct 45181510 Multivent MV250 57181520 Lo-Carbon Multivent MVDC 56183010 Multivent MV250H 57183020 Lo-Carbon Multivent MVDCH 56188110 LuminAir L 34188210 LuminAir T 34188610 LuminAir H 34231710 S6SD/R 139232710 S7SD/R 139233710 S9SD/R 139234710 S12SD/R 139248710 Minivent SK 49248810 Minivent SKT 49249944 Horizontal 45° Bend 112251110 VA100LP 28251210 VA100LT (Timer) 28251310 VA100XP (Shutter) 28251410 VA100XT (Timer/Shutter) 28251510 VA100XHT (Shutter/Humidity/Timer) 28251610 VA100LHP (Humidity) 28251710 VA100XHP (Shutter/Humidity) 28254100 Wall Kit brown 119254101 Window Fitting Kit 119254102 Wall Kit white 119256120 Centrif Duo P 43256220 Centrif Duo T (Timer) 43256320 Centrif Duo DP (Two Speed) 43256420 Centrif Duo HTP (Humidity) 43258110 VA100SVL12 29258112 VA100SVLHP12 29258310 VA100SVX12 29258312 VA100SVXH12 29258410 VA100SVXT12 29258512 VA100SVXHT12 29370127 Round to Rectangular Adaptor 114370172 Acoustic Insulated Ducting 100mmØ 115370173 Acoustic Insulated Ducting 125mmØ 115370174 Acoustic Insulated Ducting 150mmØ 115370175 Acoustic Insulated Ducting 200mmØ 115370176 Acoustic Insulated Ducting 250mmØ 115370178 Acoustic Insulated Ducting 315mmØ 115370179 Acoustic Mat 118370202 90° Bend 200Ø 116370203 90° Bend 250Ø 116370238 Equal Tee 200Ø 116370239 Equal Tee 250Ø 116370249 Diffuser with integral Fire Fire Damper 118370295 90° Bend 114370299 Circular Connector 150Ø 114370302 Reducer R125/100 116370303 Reducer R150/100 116370304 Reducer R150/125 116370307 Reducer R200/150 116370309 Reducer R250/200 116370310 Reducer R300/100 116370312 Reducer R300/200 116370328 RD104TC Louvre Grille with Spigot 117230 T: 0844 856 0590


InformationStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page370329 RD104BR Louvre Grille with Spigot 117370330 RD104WH Louvre Grille with Spigot 117370336 Single Air Brick Horizontal - White 113370337 RD604BR Louvre Grille with Spigot 117370338 RD604TC Louvre Grille with Spigot 117370346 TIM2 Overrun Timer 185370356 VCON6 184370357 VCON77 185370360 Wholehouse Insulation Jacket 118370377 HR100R 102370394 HR300 73370402 HR300 Filters 73370421 Extension Wall Sleeve 72370422 Extension Sleeve 73370426 Flexible Silencer F5100 118370447 HR500IP 108370450 HR500D 107370451 HR500EP 108370552 HR400 105371301 Collar for Exhaust & 117372004 90° Bend 100Ø 114372005 45° Bend 100Ø 114372006 Circular Connector 100Ø 114372007 Equal Tee Uninsulated MMM 100Ø 114372010 90° Bend - Pre Insulated 100Ø 114372011 45° Bend - Pre Insulated 100Ø 114372012 Equal Tee - Pre Insulated 100Ø 114372075 Equal Tee - Pre Insulated 150Ø 114372076 90° Bend - Pre Insulated 150Ø 114372101 Single Air Brick Horizontal - Beige 113372210 Single Air Brick Horizontal - Brown 113372261 Lo-Carbon HR25 71372262 Lo-Carbon HR25H 71372264 Lo-Carbon HR25L 71372265 Lo-Carbon HR25LH 71400144 Flush metal wall box 176400733 Flat Channel End Cap 113400735 Flat Channel Connector with Damper 110x54 112400740 Round to Rectangular Adaptor 100mm 125Ø 114400742 RD604WH Louvre Grille with Spigot 117400743 Louvred Grille with Flyscreen 113400745 Clip 110x54 113400749 Equal Tee 100Ø 116400750 Equal Tee 125Ø 116400751 Equal Tee 150Ø 116400752 90° Bend 100Ø 116400753 90° Bend 125Ø 116400754 90° Bend 150Ø 116400755 Female Coupler 100Ø 116400756 Female Coupler 125Ø 116400757 Female Coupler 150Ø 116400758 Balancing Damper 100Ø 116400759 Balancing Damper 125Ø 116400760 Balancing Damper 150Ø 116400761 Flanged Spigot 100Ø 116400776 Flame Retardant Filter 118400788 Resettable Fire Dampers 100Ø 118400789 Resettable Fire Dampers 125Ø 118400790 Resettable Fire Dampers 150Ø 118400900 Spiral Ductwork - 3 m length 100Ø 116400901 Spiral Ductwork - 3 m length 125Ø 116400902 Spiral Ductwork - 3 m length 150Ø 116403024 Flat Channel Duct 1m 118403025 Flat Channel Duct 1.5m 118403026 Flat Channel Connector 118403027 Elbow bend 100mm 118403028 Horizontal 90 degree bend 118403029 Vertical 90 degree bend 118403030 Channel Fixing clip 118403031 Round Adaptor 220x90x150mm 118410020 Surface mount box 177410922 Spiral Ductwork - 3 m length 200Ø 116410923 Spiral Ductwork - 3 m length 250Ø 116410924 Spiral Ductwork - 3 m length 315Ø 116410925 Equal Tee 315Ø 116410927 Female Coupler 200Ø 116410928 Female Coupler 250Ø 116410929 Female Coupler 315Ø 116410930 Balancing Damper 200Ø 116410931 Balancing Damper 250Ø 116410932 Balancing Damper 315Ø 116425497 Round to Rectangular Adaptor 225 x 25 114426035 Multivent Wireless Controller 56426250 Convector Heater 171426416 Push Button Timer 182426418 PIR Timer Switch 183426715 VAFH2TC Fan Heater 171427166 Rimini Cookerhood 48427281 Eclipse 100XP 50427282 Eclipse 100XT 50427283 Eclipse 150X 50427310 Eclipse 100X 50427313 Eclipse 150XP 50427360 90˚ Bend Uninsulated 125Ø 114427477 Solo Plus P (Pullcord) 37427478 Solo Plus T (Timer) 37427479 Solo Plus HT (Humidistat-timer) 37427480 Solo Plus TM (Timer/PIR) 37427481 Lo-Carbon Solo Plus P 16427482 Lo-Carbon Solo Plus T 16427483 Lo-Carbon Solo Plus HT 16427484 Lo-Carbon Solo Plus TM 16427485 Lo-Carbon Solo Plus SELV P 16427486 Lo-Carbon Solo Plus SELV T 16W: www.vent-axia.com 231


Stock Reference IndexStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page427487 Lo-Carbon Solo Plus SELV HT 16427488 Lo-Carbon Solo Plus SELV TM 16427583 12” Wall Fan 155427584 Box Fan 155427935 Easy Dry Range 1kW 148427936 Easy Dry Range 2kW 148428049 Ceiling Fan HL 90 153428050 Ceiling Fan HL 120 153428051 Ceiling Fan HL 140 153428238 SAC5 Reversible Controller 153428630 Round 2m Ducting Insulated 125Ø 114428631 Equal Tee - Pre Insulated 125Ø 114428632 Reducer 150 -125Ø 114428633 Circular Connector 125Ø 114428635 90° Bend - Pre Insulated 125Ø 114428636 Equal Tee 125Ø 114431515 Easy Dry 1.5kW Metal 148431590 45° Bend - Pre Insulated 114431613 Centrif Duo Plus P 44431614 Centrif Duo Plus T 44431615 Centrif Duo Plus DP 44431616 Centrif Duo Plus HTP 44432504 Shower Fan & Light Kit Basic 49432505 Shower Fan & Light Kit Timer 49433257 CO2 + Temp Room Sensor 60433546 Desk Fans 9” 155433547 Desk Fans 12” 155433548 Desk Fans 16” 155433549 16” Pedestal Fan 155434036 Lo-Carbon HR25 Solo Plus 70434656 Quick Fix Termination 120434715 Round 2m Ducting Uninsulated 125Ø 114434720 Weatherproof Touch Activated Timer 183435004 HR100RS 102435131 Intumescent Fire Collar 110x54 118435132 Intumescent Fire Collar 206x60 118435133 Intumescent Fire Collar 225x55 118435134 Intumescent Fire Collar 100Ø 118435135 Intumescent Fire Collar 125Ø 118435136 Intumescent Fire Collar 150Ø 118435137 Intumescent Firewrap 110x54 118435138 Intumescent Firewrap 204x60 118435421 Tower Fan 155435424 Turbodry White Manual 148435427 Turbodry White Auto 148435430 Turbodry Chrome Auto 148435740 Filters (2 Pack) for HR25 Solo Plus 70435956 Current sensor 6m cable 183435957 Current sensor 12m cable 183435958 Temperature sensor 6m cable 183435959 Temperature sensor 12m cable 183435960 <strong>Vent</strong>wise 183435994 Current sensor 4m cable 183435995 Temperature sensor 4m cable 183436064 Lo-Carbon VA100 SELV XHTP 10436084 Napoli Cooker Hood - Silver 48436297 Easy Dry 1.5kW ABS 148436480 Eclipse Chrome Bezel 50436494 VARSU Air curtain switch 170436519 Toilet/Bathroom BAS100B 49436520 Toilet/Bathroom BAS100P 49436521 Toilet/Bathroom BAS100T 49436525 Kitchen BAS150B 49436526 Kitchen BAS150P 49436527 Kitchen BAS150T 49436530 Toilet/Bathroom BAS100SLB 49436532 Toilet/Bathroom BAS100SLT 49436533 Kitchen/Utility BAS150SLB 49436535 Kitchen/Utility BAS150SLT 49436551 Horizontal T-Piece 204x60 112436580 PVC Flexible Ducting 100Ø 115436584 PVC Flexible Ducting 125Ø 115436588 PVC Flexible Ducting 150Ø 115436592 PVC Flexible Ducting 200Ø 115436599 Flat Channel 110x54 duct 112436602 Horizontal 90° Bend 110x54 112436603 Vertical 90° Bend 110x54 112436605 Flat Channel Connector 110x54 112436606 Flat Channel Wall Plate 110x54 113436607 Elbow Bend with 100mm Spigot 110x54 112436608 Elbow Bend with Socket 110x54 112436609 Grille Adaptor 110x54 113436610 Horizontal Louvred Grille 110x54 113436611 Horizontal Louvred Grille 204x60 113436612 Horizontal Louvred Grille 204x60 113436613 Horizontal Louvred Grille 204x60 113436614 Horizontal T-Piece 110x54 112436617 Flat Channel 204x60 112436620 Horizontal 90° Bend 204x60 112436621 Vertical 90° Bend 204x60 112436622 Clip 204x60 113436623 Connector 204x60 112436624 Elbow Bend with 100mm Spigot 204x60 112436625 Elbow Bend with 125mm Spigot 204x60 112436626 Elbow Bend with 150mm Spigot 204x60 112436632 Flat Channel 225x25 112436635 Horizontal 90° Bend 225x25 112436636 Vertical 90° Bend F To F 225x25 112436638 Clip 225x25 113436639 Connector 225x25 112436640 Elbow bend with 90˚ spigot 225x25 112436642 Air Grille Adaptor 225x25 113437078 Solo Plus Bezel 37437231 Tempest Hand Dryer 146232 T: 0844 856 0590


InformationStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page437320 Momentary Push Switch 184437598 Integral Humidistat 60437601 Lo-Carbon Sentinel Multivent 58437634 Lo-Carbon Multivent MVDC-MS 61437666 Integra Plus 101437827 Wireless Transmitter Controller 60438195 Multivent Acoustic Lining Kit 72438222 Sentinel Kinetic B 88438342 Sentinel Kinetic V 88438594 Soldier Louvred Grille 110x54 113438604 Double Louvred Airbrick - White 113438605 Double Louvred Airbrick - Brown 113438606 Double Louvred Airbrick - Beige 113438607 Double Louvred Airbrick - Terracotta 113438608 Double Airbrick Adaptor 113438919 VACSH 12A 168438920 VACSH 18A 168438921 VACSH 24A 168439034 VAPH075 Panel Heater 167439035 VAPH 125 Panel Heater 167439036 VAPH 150 Panel Heater 167439037 VAPH 200 Panel Heater 167439038 VAPH 075T Panel Heater 167439039 VAPH 125T Panel Heater 167439040 VAPH 150T Panel Heater 167439041 VAPH 200T Panel Heater 167439181 Lo-Carbon Quadra HTP 20439251 Lo-Carbon Quadra TP 20439253 Lo-Carbon Quadra TM 20439256 Flush mounting Kit 20439352 Wireless Transmitter Controller Receiver Kit 60439355 VASH 6 169439356 VASH 12 169439357 VASH 18 169439358 VASH 24 169439359 VASH 12A 169439360 VASH 18A 169439361 VASH 24A 169439463 Polished Stainless Hand Dryer 146439464 Satin Stainless Hand Dryer 146439927 Quadra & Centrif filter 20439974 Silhouette 100SVB 31439975 Silhouette 100SVT 31439976 Silhouette 100SVH 31441214 Splicing Kit 160441421 Minivent Shower Fan - Basic 18441422 Minivent Shower Fan - Timer 18441423 Lo-Carbon <strong>Vent</strong>-A-Light Fan & Light - Standard 19441424 Lo-Carbon <strong>Vent</strong>-A-Light Fan & Light - Timer 19441483 Lo-Carbon Sentinel Kinetic CW L 84441484 Lo-Carbon Sentinel Kinetic CS L 84441485 Lo-Carbon Sentinel Kinetic CW R 84441486 Lo-Carbon Sentinel Kinetic CS R 84441511 Lo-Carbon Silhouette 100SVB 12441512 Lo-Carbon Silhouette 100SVT 12441513 Lo-Carbon Silhouette 100SVH 12441614 Lo-Carbon VA100 SELV LP 10441615 Lo-Carbon VA100 SELV LT 10441616 Lo-Carbon VA100 SELV LHTP 10441624 Lo-Carbon Silhouette 100B 12441625 Lo-Carbon Silhouette 100T 12441626 Lo-Carbon Silhouette 100HT 12441628 Lo-Carbon Silhouette 150B 24441629 Lo-Carbon Silhouette 150T 24441630 Lo-Carbon Silhouette 150HT 24441654 Round to Rectangle Adaptor 114441655 Vertical 45˚ Bend 110x54 112441656 Vertical 45˚ Bend 225x25 112441657 45˚ Bend Uninsulated 114441774 Kinetic Spare Filters - 2 pack 88441780 <strong>Vent</strong>-Wise controller 88441780 <strong>Vent</strong>-Wise controller 88441782 Lo-Carbon Centra 14441865 Wireless enable kit 80442030 Isolator Relay Controller 185442273 Drop down section 113442356 Kinetic V Spare Filters - 2 pack 88442551 Decoration Frame 119442865 Lo-Carbon Quadra SVTP 20442866 Lo-Carbon Quadra SVHTP 20442867 Lo-Carbon Quadra SVTM 20442947 Window Fitting Kit Centra/Silhouette 100 119442954 Lo-Carbon Centra T 14442955 Lo-Carbon Centra HT 14443028 Lo-Carbon Kinetic Plus B 80443045 Lo-Carbon Centra HTP 14443159 Lo-Carbon VA100 LP (Pullcord) 10443160 Lo-Carbon VA100 XP (Shutter/Pullcord) 10443161 Lo-Carbon VA100 LT (Timer) 10443162 Lo-Carbon VA100 XT (Shutter/Timer) 10443163 Lo-Carbon VA100 LHTP (Humidity/Pullcord) 10443164 Lo-Carbon VA100 XHTP (Shutter/Humidity/Pullcord) 10443175 Lo-Carbon Centra SELV T 14443176 Lo-Carbon Centra SELV HT 14443177 Lo-Carbon Centra SELV HTP 14443234 Window Fitting Kit VA100 (110Ø) 119443283 Wired remote controller 88443283 Wired Remote Controller 88443298 Lo-Carbon Multivent MVDC-MSH 61443303 Lo-Carbon Kinetic E 98443310 Lo-Carbon Tempra T 68443311 Lo-Carbon Tempra HTP 68443312 Lo-Carbon Tempra P 68443319 Sentinel Kinetic BH 88W: www.vent-axia.com 233


Stock Reference IndexStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page443351 Kinetic Spare Filters - 2 pack 80443811 Lo-Carbon Quadra TP Datalogger 20443812 Lo-Carbon Quadra HTP Datalogger 20444075 Lo-Carbon Pozidry 62444076 Lo-Carbon Pozidry Compact 64444199 Kinetic Spare F5 pollen filter 98444200 Kinetic B/BH Spare F5 pollen filter 79444201 Kinetic Spare F5 pollen filter 80444368 Lo-Carbon Tempra SELV P 68444369 Lo-Carbon Tempra SELV T 68444370 Lo-Carbon Tempra SELV HTP 68444672 Lo-Carbon Centra CO2 and Humidity 14444696 Overload 0.16-0.25 198444697 Overload 0.25-0.40 198444698 Overload 0.40-0.63 198444699 Overload 0.63-1.0 198444700 Overload 1.0-1.6 198444701 Overload 1.6-2.5 198444702 Overload 2.5-4.0 198444703 Overload 4.0-6.0 198444704 Overload 5.5-8.0 198444705 Overload 7-10 198444706 Overload 10 - 13 198444707 Overload 13- 18 222444708 Overload 18-25 222444709 Overload 23-32A 222444766 Lo-Carbon Pozidry with integral heater 62444744 DOL Starter 1 Phase 240V 12A 222444745 DOL Starter 1 Phase 240V 25A 222444746 DOL Starter 1 Phase 240V 32A 222444747 DOL Starter 3 Phase 415V 12A 222444748 DOL Starter 3 Phase 415V 25A 222444749 DOL Starter 3 Phase 415V 32A 222444750 DOL Starter 3 Phase 415V 50A 222444842 Star Delta Starter 21A 222444843 Star Delta Starter 30A 222444767 Lo-Carbon Pozidry Compact with integral heater 64444956 Lo-Carbon eTempest 146444959 Tempest Filter Assembly Pack 146444960 Tempest Filter Replacement 146445161 Silhouette 125B 33445162 Silhouette 125T 33445163 Silhouette 125H 33445196 Vertical 45˚ Bend 112445655 Sentinel Multivent H 58446174 Underfloor Heating Thermostatic Controller 160446175 Underfloor Heat Mat 100 1m 2 158446176 Underfloor Heat Mat 100 1.5m 2 158446177 Underfloor Heat Mat 100 2m 2 158446178 Underfloor Heat Mat 100 2.5m 2 158446179 Underfloor Heat Mat 100 3m 2 158446180 Underfloor Heat Mat 100/HS 3.5m 2 158446181 Underfloor Heat Mat 100/HS 4m 2 158446182 Underfloor Heat Mat 100/HS 5m 2 158446183 Underfloor Heat Mat 100/HS 6m 2 158446184 Underfloor Heat Mat 100/HS 7m 2 158446185 Underfloor Heat Mat 100/HS 8m 2 158446186 Underfloor Heat Mat 100/HS 10m 2 158446187 Underfloor Heat Mat 100/HS 12m 2 158446188 Underfloor Heat Mat 150 1m 2 158446189 Underfloor Heat Mat 150 1.5m 2 158446190 Underfloor Heat Mat 150 2m 2 158446191 Underfloor Heat Mat 150 2.5m 2 158446192 Underfloor Heat Mat 150 3m 2 158446193 Underfloor Heat Mat 150/HS 3.5m 2 158446194 Underfloor Heat Mat 150/HS 4m 2 158446195 Underfloor Heat Mat 150/HS 5m 2 158446196 Underfloor Heat Mat 150/HS 6m 2 158446197 Underfloor Heat Mat 150/HS 7m 2 158446198 Underfloor Heat Mat 150/HS 8m 2 158446199 Underfloor Heat Mat 150/HS 10m 2 158446200 Underfloor Heat Mat 150/HS 12m 2 158446201 Underfloor Heat Cable 300W 159446202 Underfloor Heat Cable 400W 159446203 Underfloor Heat Cable 500W 159446204 Underfloor Heat Cable 600W 159446205 Underfloor Heat Cable 700W 159446206 Underfloor Heat Cable 840W 159446207 Underfloor Heat Cable 1500W 159446208 Underfloor Heat Cable 12500W 159446209 Underfloor Heat Cable 1370W 159446210 Underfloor Heat Cable 1700W 159446211 Underfloor Heat Cable 2150W 159446212 Underfloor Heat Cable 2600W 159446213 Underfloor Heat Cable 3300W 159446214 Splicing Kit for Underfloor Heating Cables 160446269 Lo-Carbon Quadra SVTP Datalogger 20446270 Lo-Carbon Quadra SVHTP Datalogger 20446483 Lo-Carbon Silhouette 125B 22446484 Lo-Carbon Silhouette 125T 22446485 Lo-Carbon Silhouette 125HT 22446658 Silent Fan VASF100B 32446659 Silent Fan VASF100T 32446756 Lo-Carbon Sentinel Kinetic CWH L 84446757 Lo-Carbon Sentinel Kinetic CSH L 84446758 Lo-Carbon Sentinel Kinetic CWH R 84446759 Lo-Carbon Sentinel Kinetic CS R 84446877 Portable Insect Killer 149446878 Insect Killer 50 149446879 Insect Killer 80 149446880 Insect Killer 150 149447127 Lo-Carbon Centra TP 14447128 Lo-Carbon Centra SELV TP 14447267 Underfloor Heat Insulation Boards 6mm 161234 T: 0844 856 0590


InformationStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page447268 Underfloor Heat Insulation Boards 10mm 161447269 Underfloor Heat Insulation Boards 12mm 161447270 Underfloor Heat Insulation Boards 20mm 161447271 Underfloor Heat Insulation Boards 30mm 161447272 Underfloor Heat Insulation Boards 40mm 161447273 Underfloor Heat Insulation Boards 50mm 161447274 Underfloor Heat Insulation Boards 60mm 161447275 Underfloor Heat Insulation Boards 70mm 161447276 Underfloor Heat Insulation Boards Tape 161447277 Underfloor Heat Insulation Boards 10mm Screws 161447278 Underfloor Heat Insulation Boards 20mm Screws 161447279 Underfloor Heat Insulation Boards 30mm Screws 161447280 Underfloor Heat Insulation Boards 40mm Screws 161447281 Underfloor Heat Insulation Boards 50mm Screws 161447282 Underfloor Heat Insulation Boards 60mm Screws 161447283 Underfloor Heat Insulation Boards Washers 161447335 Rigid Duct Attenuator 500mm 118447336 Rigid Duct Attenuator 1000mm 118447340 Opto-Coupler 84447425 Jet Dry 146447600 Radiant Heater VAR0 1800 165447602 Radiant Heater VARI 2000 165447603 Radiant Heater VARI 4000 165447604 Radiant Heater VARI 6000 165447801 Lo-Carbon Sentinel Kinetic Horizontal 300Z 92447854 VATRS100C Towel Rail 162447855 VATRF150C Towel Rail 162447856 VATRF250W Towel Rail 162447857 VATRF250C Towel Rail 162447858 VATRF400C Towel Rail 162447859 VATRC250C Towel Rail 162447860 VATRC400C Towel Rail 162447861 Atacama LS Towel Rail 162447862 Atacama OS Towel Rail 162447863 Atacama SS Towel Rail 162447864 VATRCW Controller 162447865 VATRCC Controller 162447866 VATRDFK150 Replacement Element 162447867 VATRDFK250 Replacement Element 162447868 VATRDFK400 Replacement Element 162448356 LED Indicator 184448469 Opal Aluminium Radiators 500W 166448470 Opal Aluminium Radiators 750W 166448471 Opal Aluminium Radiators 1000W 166448472 Opal Aluminium Radiators 1250W 166448473 Opal Aluminium Radiators 1500W 166448733 Lo-Carbon Sentinel Kinetic Horizontal 200Z 92448919 Portable Air Conditioner 154449059 Lo-Carbon Kinetic Plus E 96449060 Normal Boost Switch with Light Indicator 184449071 PIV Twin Spigot Kit 62449361 Elbow bend 125mm 118449362 Elbow bend 150mm 118449363 Horizontal 45 degree bend 118449364 Vertical 45 degree bend 118449365 Horizontal T 118449366 3M Flexible Rectangular duct 118449368 Attenuated Duct 500mm 118449369 Attenuated Duct 1000mm 118449536 Lo-Carbon Sentinel Kinetic Horizontal 300ZH 92449540 Lo-Carbon Sentinel Kinetic Horizontal 200ZH 92452044 LuminAir Bezels Chrome 35452045 LuminAir Bezels Gold 35452076 Duct Y-Piece 250/250mm 115452077 Duct Y-Piece 300/300mm 115452078 Duct Y-Piece 250/250mm 115452079 Duct Y-Piece 250/300mm 115452080 Duct Y-Piece 200/350mm 115452081 Duct Y-Piece 100/100mm 115452082 Duct Y-Piece 100/150mm 115452083 Duct Y-Piece 150/150mm 115452084 Duct Y-Piece150/200mm 115452085 Duct Y-Piece 200/200mm 115452094 100mm Cowl - White 121452095 100mm Cowl - Brown 121452096 150mm Cowl - White 121452097 150mm Cowl - Brown 121452550 Replacement Grease Filter 355 138452551 Replacement Grease Filter 450 138452725 Heavy Duty wall fan Grille size 6 192452726 Heavy Duty wall fan Grille size 7 192452727 Heavy Duty wall fan Grille size 9 192452728 Heavy Duty wall fan Grille size 12 192452814 Replacement Air Filters 355 138452815 Replacement Air Filters 450 138453182 Freshvent 100 Thermo 47453188 Filter for Freshvent 100 47453197 Filter for Freshvent 100 Thermo 47453200 Freshvent 100 47453206 Storm Sheild for Freshvent 47453208 Freshvent 100 dB 47453253 Freshvent 100 Thermo dB 47453395 LuminAir <strong>Vent</strong> Light SELV Duct Air Inlet 34453410 LuminAir Shower <strong>Vent</strong>ilation Kit L - White 35453413 LuminAir Shower <strong>Vent</strong>ilation Kit T - White 35453416 LuminAir Shower <strong>Vent</strong>ilation Kit H - White 35453419 LuminAir Turbo SKL 36453422 LuminAir Turbo SKT 36453915 Hand Dryer + Dryline 147454055 Silhouette 100B 30454056 Silhouette 100T 30454057 Silhouette 100H 30454058 Silhouette 100TM 30454059 Silhouette 150X 42W: www.vent-axia.com 235


Stock Reference IndexStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page454060 Silhouette 150XT 42454061 Silhouette 150XH 42455035 Short Round to Rectangular Adaptor 114455190 Condensation Trap 150mm 121455191 Condensation Trap 125mm 121455204 Aircheck H40/70 - Bathroom 117455206 Aircheck H65/120 - Kitchen/Utility 117455207 Supply Diffusers Aircheck A15/40 - WC 117455208 Aircheck A65/120 - Kitchen 117455211 Duct Y Piece 2x 125mm into 1x 125mm 115455212 Duct Y Piece 2x 125mm into 1x 150mm 115455213 Normal Boost Switch 184455219 Aircheck Ceiling adaptor - (CA125) 117455226 125mm Wall Kits 33455262 Window wind cowl 121455834 Downflow Heater 170455873 Controllers wired T-series 128455874 Controllers wire-less T-series 128456165 Lo-Carbon T-Series 9” Window - Wired 128456166 Lo-Carbon T-Series 9” Wall - Wired 129456167 Lo-Carbon T-Series 9” Panel - Wired 131456168 Lo-Carbon T-Series 9” Roof - Wired 130456169 Lo-Carbon T-Series 9” Window - Wireless 128456170 Lo-Carbon T-Series 9” Wall - Wireless 129456171 Lo-Carbon T-Series 9” Panel - Wireless 131456172 Lo-Carbon T-Series 9” Roof - Wireless 130456173 Lo-Carbon T-Series 12” Window - Wired 128456174 Lo-Carbon T-Series 12” Wall - Wired 129456175 Lo-Carbon T-Series 12” Panel - Wired 131456176 Lo-Carbon T-Series 12” Roof - Wired 130456177 Lo-Carbon T-Series 12” Window - Wireless 128456178 Lo-Carbon T-Series 12” Wall - Wireless 129456179 Lo-Carbon T-Series 12” Panel - Wireless 131456180 Lo-Carbon T-Series 12” Roof - Wireless 130456343 Warmair 3 170456344 Warmair 4.5 170456345 Warmair 6 170456864 Integra 100457479 Gemini Surface Twin fan 46457480 Gemini Recessed Twin fan 46457481 Gemini Duct Twin fan 46457485 Jupiter - NJUP315 152457486 Jupiter - NJUP315CTS 152457487 Jupiter - NJUP400 152457488 Jupiter - NJUP400CTS 152457490 Suspension Pack 152457845 100mm Wind Cowl 119457986 Remote delay timer 181458153 Fan Speed Adjuster 182458915 VA140/150VS 40459049 Lo-Carbon VA100 SELV XP 10459050 Lo-Carbon VA100 SELV XT 10459112 VAPL2-S 170459113 VAPL2-W 170459114 VAPL2-B 170459115 VAPL2TC-S 170459116 VAPL2TC-W 170459117 VAPL2TC-B 170459123 Lo-Carbon VA150P 23459124 Lo-Carbon VA150T 23459125 Lo-Carbon VA150HP 23459623 <strong>Vent</strong>-<strong>Axia</strong> Visionex PIR 225 x 25 181459624 <strong>Vent</strong>-<strong>Axia</strong> Visionex SELV 12 PIR 181459664 Tamper Proof Window Kit 120459746 2-Way Switch and Neons 185460086 T-Series Wall Liner’s size 6 187460094 T-Series Wall Liner’s size 7 187460095 T-Series Wall Liner’s size 9 187460096 T-Series Wall Liner’s size 12 187460585 T-Series Darkroom Cowl Assembly size 6 188460586 T-Series Darkroom Cowl Assembly size 7 188460587 T-Series Darkroom Cowl Assembly size 9 188460588 T-Series Darkroom Cowl Assembly size12 188462195 Horizontal 45˚ Bend 112466783 Reducer Cone 92467790 Intumescent Firewrap 118468728 Terracotta Soldier Louvred Airbrick 113468729 Beigh Soldier Louvred Airbrick 113468730 Brown Soldier Louvred 113560136 Roof Plate Assemblies size 6 193560137 Roof Plate Assemblies size 7 193560139 Roof Plate Assemblies size 9 193560142 Roof Plate Assemblies size 12 193560161 Roof Termination 6RF 191560162 Roof Termination 7RF 191560163 Roof Termination 9RF 191560164 Roof Termination 12RF 191560236 Mounting Boxes 6/7 187560239 Mounting Boxes 9/12 187560501 Direct Mount Spigot size 6 188560502 Direct Mount Spigot size 7 188560503 Direct Mount Spigot size 9, WW/RF 188560504 Direct Mount Spigot size 9, WL/PL 188560505 Direct Mount Spigot size 12 188560601 Plenum Box 125/150mm 189560602 Plenum Box 150/175mm 189560603 Plenum Box 200/225mm 189560604 Plenum Box 250/300mm 189560605 Plenum Box 315/400mm 189560637 Single Spigots 6 175mm(B) 187560639 Single Spigots 6/7 225mm(B) 187560640 Single Spigots 7 250mm(A) 187560642 Single Spigots 9 300mm(A) 187560734 2-3-4 Spigot Plate 188236 T: 0844 856 0590


InformationStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page560735 5 Spigot Plate 188560846 Eggcrate Grille - white, 125mm 190560847 Eggcrate Grille - white, 200mm 190560848 Eggcrate Grille - white, 250mm 190560849 Eggcrate Grille - white, 300mm 190560850 Eggcrate Grille - white, 450mm 190560856 Terminal Connector 119560900 Non-Vision Grille + Flanges - brown 150mm 192560901 Non-Vision Grille + Flanges - brown 300mm 192560910 External Louvres - brown, 225mm 192560911 External Louvres - brown, 300mm 192560912 External Louvres - brown, 400mm 192560913 External Louvres - brown, 450mm 192560936 Cone Connectors size 6 188561011 Standard Range Adaptor Kits - Size 6 193561012 Standard Range Adaptor Kits - Size 7 193561013 Standard Range Adaptor Kits - Size 9 193561014 Standard Range Adaptor Kits - Size 12 193561136 Fixing Plates 6 186561137 Fixing Plates 7 186561139 Fixing Plates 9 186561142 Fixing Plates 12 186561301 Eggcrate Grille - satin, 300mm 190561302 Eggcrate Grille - satin, 450mm 190561303 Eggcrate Grille - satin, 200mm 190561305 Eggcrate Grille - satin, 250mm 190561311 Non-Vision Grille - satin, 300mm 191561312 Non-Vision Grille - satin, 450mm 191561321 Non-Vision Grille - satin, 300mm 191561322 Non-Vision Grille - satin, 450mm 191561341 Opposed Blade Dampers - 200mm 190561342 Opposed Blade Dampers - 250mm 190561343 Opposed Blade Dampers - 300mm 190561344 Opposed Blade Dampers - 450mm 190561350 External Louvres Satin Finish 192561351 External Louvre Satin, 225mm 192561352 External Louvres Satin, 300mm 192561355 External Louvres Satin, 450mm 192561370 Single Deflection Grille 200mm 189561371 Single Deflection Grille 250mm 189561372 Single Deflection Grille 300mm 189561373 Single Deflection Grille 450mm 189561380 Double Deflection Grille 200mm 189561381 Double Deflection Grille 250mm 189561382 Double Deflection Grille 300mm 189561383 Double Deflection Grille 450mm 189561390 Non-Vision Grille + Flange - satin 0/150mm 192561391 Non-Vision Grille + Flange - satin 0/300mm 192561400 Air replacement Grille Set - brown 121561401 Air replacement Grille Set - Ivory 121561403 <strong>Vent</strong> Cowl 121561411 louvre Grille - size 6, brown 192561412 louvre Grille - size 7, brown 192561413 louvre Grille - size 9, brown 192561414 louvre Grille - size 12, brown 192561421 louvre Grille - size 6 white 192561422 louvre Grille - size 7 white 192561423 louvre Grille - size 9 white 192561424 louvre Grille - size 12 white 192561654 Insulated Flexible Ducting -100mm 115561655 Insulated Flexible Ducting -125mm 115561656 Insulated Flexible Ducting -150mm 115561658 Insulated Flexible Ducting -200mm 115561660 Insulated Flexible Ducting -250mm 115561662 Insulated Flexible Ducting -315mm 115561704 Worm Drive Clips - 110mm 193561707 Worm Drive Clips - 180mm 193561710 Worm Drive Clips - 270mm 193561715 Worm Drive Clips - 380mm 193561720 Worm Drive Clips - 525mm 193561726 Worm Drive Clips - 600mm 193561804 Joining Piece - 100mm Ø 193561805 Joining Piece - 125mm Ø 193561806 Joining Piece - 150mm Ø 193561808 Joining Piece - 200mm Ø 193561809 Joining Piece - 225mm Ø 193561810 Joining Piece - 250mm Ø 193561812 Joining Piece - 300mm Ø 193561813 Joining Piece - 315mm Ø 193561816 Joining Piece - 400mm Ø 193561901 Fire Damper size 6/7 191561902 Fire Damper size 9/12 191562030 5-Core Flexible Cord per metre 193562031 5-Core Flexible Cord 50m 193563000 Joining Bolt Set 187563106 Standard Range Protective Grille - size 6 188563107 Standard Range Protective Grille - size 7 188563109 Standard Range Protective Grille - size 9 188563112 Standard Range Protective Grille - size 12 188563406 Standard Range Protective Grille - size 6 188563407 Standard Range Protective Grille - size 7 188563409 Standard Range Protective Grille - size 9 188563412 Standard Range Protective Grille - size 12 188563500 Air Grille white 120563501 <strong>Vent</strong>-<strong>Axia</strong> HumidiSwitch 179563502 <strong>Vent</strong>-<strong>Axia</strong> ThermoSwitch 180563506 Air Quality Sensor 177563511 Air Grille brown 120563513 Termination Set 119563515 7 Day TimeSwitch 180563516 Condensation Trap 121563517 Ducting Pack 120563518 3 Pole Isolator 181563519 TimeSpan Controller 177W: www.vent-axia.com 237


Stock Reference IndexStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page563521 Quick Fix Wall Grille - white 120563522 Quick Fix Airflow Shutter - white 120563531 Ecotronic SELV 12 179563532 Ecotronic Humidity Sensor 179563533 3 Speed Controller 185563535 Quick Fix Termination 120563538 150VA Transformer 185563541 Quick Fix Wall Grille - brown 120563542 Quick Fix Airflow Shutter - brown 120563548 Guardian Personnel Detector 180563550 Ambient Response 178563551 Ambient Response SELV 12 178563552 Lo-Carbon Ambient Response 178566142 Single Spigot size 9 187566146 Single Spigot size 12 187566607 PVC Flexible Ducting 175Ø 115566609 PVC Flexible Ducting 225Ø 115566612 PVC Flexible Ducting 300Ø 115566616 PVC Flexible Ducting 400Ø 115568104 Fixing Rod Set size 6/7/9 186568106 Fixing Rod Set size 12 1865107197 Single Air Brick Horizontal - Terracota 1135108248 Ducting - 2M length (uninsulated) 150ø 1145108249 Ducting - 2M length - Pre Insulated 100ø 1145108250 Ducting - 2M length (uninsulated) 100ø 1145108251 Ducting - 2M length - Pre Insulated 150ø 1145108454 Normal Boost Purge 1845109662 Flexible Connection 204 x 60mm 11310314103 3A Transformer Controller 18210314105 5A Transformer Controller 18210314107 7A Transformer Controller 18210502325 Impeller Discharge Side Guide 250/315 19810502375 Impeller Discharge Side Guide 355 19810502450 Impeller Discharge Side Guide 400 19810502525 Impeller Discharge Side Guide 450/500 19810502630 Impeller Discharge Side Guide 560/630 19810502800 Impeller Discharge Side Guide 710/800 19810538290 Heat exchange unit HR500DP 10910539100 In-Line Flexduct - 100mm 11510539125 In-Line Flexduct - 125mm 11510539150 In-Line Flexduct - 150mm 11510539200 In-Line Flexduct - 200mm 11510539250 In-Line Flexduct - 250mm 11510539315 In-Line Flexduct - 315mm 11510539400 In-Line Flexduct - 400mm 11510543100 Round Supply Diffuser - 100mm 11710543125 Round Supply Diffuser - 125mm 11710543150 Round Supply Diffuser - 150mm 11710544100 Round Exhaust Diffuser - 100mm 11710544125 Round Exhaust Diffuser - 125mm 11710544150 Round Exhaust Diffuser - 150mm 11710544200 Round Exhaust Diffuser - 200mm 11710546230 4-Way Diffuser - 200/225mm 19010546300 4-Way Diffuser - 250/300mm 19010546350 4-Way Diffuser - 300/315/350mm 19010546400 4-Way Diffuser - 400mm 19010546450 4-Way Diffuser - 450mm 19010546500 4-Way Diffuser - 500mm 19010547150 4-Way Diffuser Neck Adptr - 150mm 19010547200 4-Way Diffuser Neck Adptr - 200mm 19010547250 4-Way Diffuser Neck Adptr - 250mm 19010547300 4-Way Diffuser Neck Adptr 300/315 19010547400 4-Way Diffuser Neck Adptr 400 19010548000 4-Way Diffuser Neck Adptr 3400/500 19010548400 4-Way Diffuser Neck Adptr 400 19010551250 3-Way Splitter - 150/250mm 11510553400 3-Way Splitter - 315/400mm 11510555150 100/125/150 Roof Termination 19110555200 200mm Roof Termination 19110555250 250mm Roof Termination 19110555315 315 mmRoof Termination 19111101010 Solo P (Pullcord) 3811101030 Solo T (Timer) 3811101060 Solo TM2 (Timer/PIR) 3811101080 Solo HTP 3811108000 Solo SELV 12 3911108020 Solo SELV 12DP (Two speed) 3911108030 Solo SELV 12T (Timer) 3911108040 Solo SELV 12HP (Humidity) 3911461685 Window Fitting Kit 11913101100 Meteor 15514101010 HR500 10614101070 HR500X (HRV1) 10614120010 HR200V 10314120020 HR200WK 7214125010 HR250 10417104010 ACM100 12417104020 ACM100T 12417105010 ACM125 12417105020 ACM125T 12417106010 ACM150 12417106020 ACM150T 12417108010 ACM200 12417108020 ACM200T 12417110010 ACM250 12517112010 ACM315 12520101402 Professional E 14720101440 Prepdry-Stainless Steel 14783010030 In-Line Attenuators 100mm Ø 300mm 22383010060 In-Line Attenuators 100mm Ø 600mm 22383010090 In-Line Attenuators 100mm Ø 900mm 22383012030 In-Line Attenuators 125mm Ø 300mm 22383012060 In-Line Attenuators 125mm Ø 600mm 22383012090 In-Line Attenuators 125mm Ø 900mm 223238 T: 0844 856 0590


InformationStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> Page83015030 In-Line Attenuators 150mm Ø 300mm 22383015060 In-Line Attenuators 150mm Ø 600mm 22383015090 In-Line Attenuators 150mm Ø 900mm 22383016030 In-Line Attenuators 160mm Ø 300mm 22383016060 In-Line Attenuators 160mm Ø 600mm 22383016090 In-Line Attenuators 160mm Ø 900mm 22383020060 In-Line Attenuators 200mm Ø 600mm 22383020090 In-Line Attenuators 200mm Ø 900mm 22383020120 In-Line Attenuators 200mm Ø 1200mm 22383025060 In-Line Attenuators 250mm Ø 600mm 22383025090 In-Line Attenuators 250mm Ø 900mm 22383025120 In-Line Attenuators 250mm Ø 1200mm 22383031060 In-Line Attenuators 315mm Ø 600mm 22383031090 In-Line Attenuators 315mm Ø 900mm 22383031120 In-Line Attenuators15mm Ø 1200mm 22383040090 In-Line Attenuators400mm Ø 900mm 22383040120 In-Line Attenuators400mm Ø 1200mm 22383050090 In-Line Attenuators500mm Ø 900mm 22383050120 In-Line Attenuators500mm Ø 1200mm 223105021000 Impeller Discharge Side Guide 1000 19820101600SX Powerdry SX 14720101800SX Ultradry SX 14720101840SX Ultradry SX Stainless Steel 14720101840SX Ultradry SX Stainless Steel 147258310BD025 VA100SVXP12 2968MP033G Anti Vibration Mounts (set of 4) 220ACOB1A Manual & Auto Changeover controller 213ACP10012 Powerflow - 100mm 126ACP12512 Powerflow - 125mm 126ACP15012 Powerflow - 150mm 126ACP16012 Powerflow - 160mm 126ACP20012 Powerflow - 200mm 126ACP25012 Powerflow - 250mm 126ACP31512 Powerflow - 315mm 126ACP31512HP Powerflow - 315mm 126ACZ2501D Attenuator 250mm Ø 1D Long No Pod 202ACZ2502D Attenuator 250mm Ø 2D Long No Pod 202ACZ3151D Attenuator 315mm Ø 1D Long No Pod 202ACZ3151DP Attenuator 315mm Ø 1D Long with Pod 202ACZ3152D Attenuator 315mm Ø 2D Long No Pod 202ACZ3152DP Attenuator 315mm Ø 2D Long with Pod 202ACZ3551D Attenuator 355mm Ø 1D Long No Pod 202ACZ3551DP Attenuator 355mm Ø 1D Long with Pod 202ACZ3552D Attenuator 355mm Ø 2D Long No Pod 202ACZ3552DP Attenuator 355mm Ø 2D Long with Pod 202ACZ4001D Attenuator 400mm Ø 1D Long No Pod 202ACZ4001DP Attenuator 400mm Ø 1D Long with Pod 202ACZ4002D Attenuator 400mm Ø 2D Long No Pod 202ACZ4002DP Attenuator 400mm Ø 2D Long with Pod 202ACZ4501D Attenuator 450mm Ø 1D Long No Pod 202ACZ4501DP Attenuator 450mm Ø 1D Long with Pod 202ACZ4502D Attenuator 450mm Ø 2D Long No Pod 202ACZ4502DP Attenuator 450mm Ø 2D Long with Pod 202ACZ5001D Attenuator 500mm Ø 1D Long No Pod 202ACZ5001DP Attenuator 500mm Ø 1D Long with Pod 202ACZ5002D Attenuator 500mm Ø 2D Long No Pod 202ACZ5002DP Attenuator 500mm Ø 2D Long with Pod 202ACZ5601D Attenuator 560mm Ø 1D Long No Pod 202ACZ5601DP Attenuator 560mm Ø 1D Long with Pod 202ACZ5602D Attenuator 560mm Ø 2D Long No Pod 202ACZ5602DP Attenuator 560mm Ø 2D Long with Pod 202ACZ6301D Attenuator 630mm Ø 1D Long No Pod 202ACZ6301DP Attenuator 630mm Ø 1D Long with Pod 202ACZ6302D Attenuator 630mm Ø 2D Long No Pod 202ACZ6302DP Attenuator 630mm Ø 2D Long with Pod 202ACZ7101D Attenuator 710mm Ø 1D Long No Pod 202ACZ7101DP Attenuator 710mm Ø 1D Long with Pod 202ACZ7102D Attenuator 710mm Ø 2D Long No Pod 202ACZ7102DP Attenuator 710mm Ø 2D Long with Pod 202ACZ8001D Attenuator 800mm Ø 1D Long No Pod 202ACZ8001DP Attenuator 800mm Ø 1D Long with Pod 202ACZ8002D Attenuator 800mm Ø 2D Long No Pod 202ACZ8002DP Attenuator 800mm Ø 2D Long with Pod 202APZ250 Ancillary Pack 250mm Ø 203APZ315 Ancillary Pack 315mm Ø 203APZ355 Ancillary Pack 355mm Ø 203APZ400 Ancillary Pack 400mm Ø 203APZ450 Ancillary Pack 450mm Ø 203APZ500 Ancillary Pack 500mm Ø 203APZ560 Ancillary Pack 560mm Ø 203APZ630 Ancillary Pack 630mm Ø 203APZ710 Ancillary Pack 710mm Ø 203APZ800 Ancillary Pack 800mm Ø 203BDS100 Back Draught Shutters 100mm Ø 215BDS125 Back Draught Shutters 125mm Ø 215BDS150 Back Draught Shutters 150mm Ø 215BDS200 Back Draught Shutters 200mm Ø 215BDS250 Back Draught Shutters 250mm Ø 215BDS315 Back Draught Shutters 315mm Ø 215BGZ400 Birdguard 400/450 207BGZ500 Birdguard 500/560 207BGZ630 Birdguard 630/710 207CFZ250 Matching Flanges 250mm Ø 203CFZ315 Matching Flanges 315mm Ø 202CFZ355 Matching Flanges 355mm Ø 202CFZ400 Matching Flanges 400mm Ø 202CFZ450 Matching Flanges 450mm Ø 202CFZ500 Matching Flanges 500mm Ø 202CFZ560 Matching Flanges 560mm Ø 202CFZ630 Matching Flanges 630mm Ø 202CFZ710 Matching Flanges 710mm Ø 202CFZ800 Matching Flanges 800mm Ø 202CVT100 Intumescent Fire Damper 4” Ø 224CVT130 Intumescent Fire Damper 5” Ø 224W: www.vent-axia.com 239


Stock Reference IndexStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> PageCVT150 Intumescent Fire Damper 6” Ø 224CVT200 Intumescent Fire Damper 8” Ø 224CVT250 Intumescent Fire Damper 10” Ø 224CVT300 Intumescent Fire Damper 12” Ø 224ESC100036 S/Cased Fan 1000mm Ø, 3 ph. 6 Pole 202ESC25012 S/Cased Fan 250mm Ø, 1 ph. 2 Pole 202ESC25014 S/Cased Fan 250mm Ø, 1 ph. 4 Pole 202ESC25032 S/Cased Fan 250mm Ø, 3 ph. 2 Pole 202ESC31512 S/Cased Fan 315mm Ø, 1 ph. 2 Pole 202ESC31514 S/Cased Fan 315mm Ø, 1 ph. 4 Pole 202ESC31532 S/Cased Fan 315mm Ø, 3 ph. 2 Pole 202ESC35512 S/Cased Fan 355mm Ø, 1 ph. 2 Pole 202ESC35514 S/Cased Fan 355mm Ø, 1 ph. 4 Pole 202ESC35516 S/Cased Fan 355mm Ø, 1 ph. 6 Pole 202ESC35532 S/Cased Fan 355mm Ø, 3 ph. 2 Pole 202ESC35534 S/Cased Fan 355mm Ø, 3 ph. 4 Pole 202ESC35536 S/Cased Fan 355mm Ø, 3 ph. 6 Pole 202ESC40014 S/Cased Fan 400mm Ø, 1 ph. 4 Pole 202ESC40016 S/Cased Fan 400mm Ø, 1 ph. 6 Pole 202ESC40034 S/Cased Fan 400mm Ø, 3 ph. 4 Pole 202ESC40036 S/Cased Fan 400mm Ø, 3 ph. 6 Pole 202ESC45014 S/Cased Fan 450mm Ø, 1 ph. 4 Pole 202ESC45016 S/Cased Fan 450mm Ø, 1 ph. 6 Pole 202ESC45034 S/Cased Fan 450mm Ø, 3 ph. 4 Pole 202ESC45036 S/Cased Fan 450mm Ø, 3 ph. 6 Pole 202ESC50014 S/Cased Fan 500mm Ø, 1 ph. 4 Pole 202ESC50016 S/Cased Fan 500mm Ø, 1 ph. 6 Pole 202ESC50034 S/Cased Fan 500mm Ø, 3 ph. 4 Pole 202ESC50036 S/Cased Fan 500mm Ø, 3 ph. 6 Pole 202ESC56014 S/Cased Fan 560mm Ø, 1 ph. 4 Pole 202ESC56016 S/Cased Fan 560mm Ø, 1 ph. 6 Pole 202ESC56034 S/Cased Fan 560mm Ø, 3 ph. 4 Pole 202ESC56036 S/Cased Fan 560mm Ø, 3 ph. 6 Pole 202ESC63014 S/Cased Fan 630mm Ø, 1 ph. 4 Pole 202ESC63016 S/Cased Fan 630mm Ø, 1 ph. 6 Pole 202ESC63034 S/Cased Fan 630mm Ø, 3 ph. 4 Pole 202ESC63036 S/Cased Fan 630mm Ø, 3 ph. 6 Pole 202ESC71016 S/Cased Fan 710mm Ø, 1 ph. 6 Pole 202ESC71034 S/Cased Fan 710mm Ø, 3 ph. 4 Pole 202ESC71036 S/Cased Fan 710mm Ø, 3 ph. 6 Pole 202ESC80034 S/Cased Fan 800mm Ø, 3 ph. 4 Pole 202ESC80036 S/Cased Fan 800mm Ø, 3 ph. 6 Pole 202ESP100036 S/Cased Fan 1000mm Ø, 3 ph. 6 Pole 199ESP100038 S/Cased Fan 1000mm Ø, 3 ph. 8 Pole 199ESP25012 Plate Fan 250mm Ø, 1 ph. 2 Pole 198ESP25014 Plate Fan 250mm Ø, 1 ph. 4 Pole 198ESP25032 Plate Fan 250mm Ø, 3 ph. 2 Pole 199ESP31512 Plate Fan 315mm Ø, 1 ph. 2 Pole 198ESP31514 Plate Fan 315mm Ø, 1 ph. 4 Pole 198ESP31532 Plate Fan 315mm Ø, 3 ph. 2 Pole 199ESP31534 Plate Fan 315mm Ø, 3 ph. 4 Pole 199ESP35514 Plate Fan 355mm Ø, 1 Ph. 4 Pole 198ESP35516 Plate Fan 355mm Ø, 1 Ph. 6 Pole 198ESP35534 Plate Fan 355mm Ø, 3 Ph. 4 Pole 199ESP35536 Plate Fan 355mm Ø, 3 Ph. 6 Pole 199ESP40014 Plate Fan 400mm Ø, 1 Ph. 4 Pole 198ESP40016 Plate Fan 400mm Ø, 1 Ph. 6 Pole 198ESP40034 Plate Fan 400mm Ø, 3 Ph. 4 Pole 199ESP40036 Plate Fan 400mm Ø, 3 Ph. 6 Pole 199ESP45014 Plate Fan 450mm Ø, 1 Ph. 4 Pole 198ESP45016 Plate Fan 450mm Ø, 1 Ph. 6 Pole 198ESP45034 Plate Fan 450mm Ø, 3 Ph. 4 Pole 199ESP45036 Plate Fan 450mm Ø, 3 Ph. 6 Pole 199ESP50014 Plate Fan 500mm Ø, 1 Ph. 4 Pole 198ESP50016 Plate Fan 500mm Ø, 1 Ph. 6 Pole 198ESP50034 Plate Fan 500mm Ø, 3 Ph. 4 Pole 199ESP50036 Plate Fan 500mm Ø, 3 Ph. 6 Pole 199ESP56014 Plate Fan 560mm Ø, 1 Ph. 4 Pole 198ESP56016 Plate Fan 560mm Ø, 1 Ph. 6 Pole 198ESP56034 Plate Fan 560mm Ø, 2 Ph. 4 Pole 199ESP56036 Plate Fan 560mm Ø, 3 Ph. 6 Pole 199ESP63014 Plate Fan 630mm Ø, 1 Ph. 4 Pole 198ESP63016 Plate Fan 630mm Ø, 1 Ph. 6 Pole 198ESP63034 Plate Fan 630mm Ø, 3 Ph. 4 Pole 199ESP63036 Plate Fan 630mm Ø, 3 Ph. 6 Pole 199ESP63038 Plate Fan 630mm Ø, 3 Ph. 8 Pole 199ESP71016 Plate Fan 710mm Ø, 1 Ph. 6 Pole 198ESP71034 Plate Fan 710mm Ø, 3 Ph. 4 Pole 199ESP71036 Plate Fan 710mm Ø, 3 Ph. 6 Pole 199ESP71038 Plate Fan 710mm Ø, 3 Ph. 8 Pole 199ESP80034 Plate Fan 800mm Ø, 3 Ph. 4 Pole 199ESP80036 Plate Fan 800mm Ø, 3 Ph. 6 Pole 199ESP80038 Plate Fan 800mm Ø, 3 Ph. 8 Pole 199ESR100036 Plate Fan 1000mm Ø, 3 Ph. 6 Pole 206ESR100038 Plate Fan 1000mm Ø, 3 Ph. 8 Pole 206ESR25012 Roof Fan 250mm Ø, 1Ph. 2 Pole 206ESR25014 Roof Fan 250mm Ø, 1Ph. 4 Pole 206ESR25032 Roof Fan 250mm Ø, 3 Ph. 2 Pole 206ESR31512 Roof Fan 315mm Ø, 1 Ph. 2 Pole 206ESR31514 Roof Fan 315mm Ø, 1 Ph. 4 Pole 206ESR31532 Roof Fan 315mm Ø, 3 Ph. 2 Pole 206ESR31534 Roof Fan 315mm Ø, 3 Ph. 4 Pole 206ESR35514 Roof Fan 355mm Ø, 1 Ph. 4 Pole 206ESR35516 Roof Fan 355mm Ø, 1 Ph. 6 Pole 206ESR35534 Roof Fan 355mm Ø, 3 Ph. 4 Pole 206ESR35536 Roof Fan 355mm Ø, 3 Ph. 6 Pole 206ESR40014 Roof Fan 400mm Ø, 1 Ph. 4 Pole 206ESR40016 Roof Fan 400mm Ø, 1 Ph. 6 Pole 206ESR40034 Roof Fan 400mm Ø, 3 Ph. 4 Pole 206ESR40036 Roof Fan 400mm Ø, 3 Ph. 6 Pole 206ESR45014 Roof Fan 450mm Ø, 1 Ph. 6 Pole 206ESR45016 Roof Fan 450mm Ø, 1 Ph. 4 Pole 206ESR45034 Roof Fan 450mm Ø, 3 Ph. 4 Pole 206ESR45036 Roof Fan 450mm Ø, 3 Ph. 6 Pole 206240 T: 0844 856 0590


InformationStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> PageESR50014 Roof Fan 500mm Ø, 1 Ph. 4 Pole 206ESR50016 Roof Fan 500mm Ø, 1 Ph. 6 Pole 206ESR50034 Roof Fan 500mm Ø, 3 Ph. 4 Pole 206ESR50036 Roof Fan 500mm Ø, 3 Ph. 6 Pole 206ESR56014 Roof Fan 560mm Ø, 1 Ph. 4 Pole 206ESR56016 Roof Fan 560mm Ø, 1 Ph. 6 Pole 206ESR56034 Roof Fan 560mm Ø, 3 Ph. 4 Pole 206ESR56036 Roof Fan 560mm Ø, 3 Ph. 6 Pole 206ESR63014 Roof Fan 630mm Ø, 1 Ph. 4 Pole 206ESR63016 Roof Fan 630mm Ø, 1 Ph. 6 Pole 206ESR63034 Roof Fan 630mm Ø, 3 Ph. 4 Pole 206ESR63036 Roof Fan 630mm Ø, 3 Ph. 6 Pole 206ESR63038 Roof Fan 630mm Ø, 3 Ph. 8 Pole 206ESR71016 Roof Fan 710mm Ø, 1Ph. 6 Pole 206ESR71034 Roof Fan 710mm Ø, 3Ph. 4 Pole 206ESR71036 Roof Fan 710mm Ø, 3 Ph. 6 Pole 206ESR71038 Roof Fan 710mm Ø, 3 Ph. 8 Pole 206ESR80034 Roof Fan 800mm Ø, 3 Ph. 4 Pole 206ESR80036 Roof Fan 800mm Ø, 3 Ph. 6 Pole 206ESR80038 Roof Fan 800mm Ø, 3 Ph. 8 Pole 206FB100 Fan box In-Line Centrifugal Duct Fans 100mm Ø 209FB125 Fan box In-Line Centrifugal Duct Fans 125mm Ø 209FB150 Fan box In-Line Centrifugal Duct Fans 150mm Ø 209FB160 Fan box In-Line Centrifugal Duct Fans 160mm Ø 209FB200 Fan box In-Line Centrifugal Duct Fans 200mm Ø 209FB250 Fan box In-Line Centrifugal Duct Fans 250mm Ø 209FB315 Fan box In-Line Centrifugal Duct Fans 315mm Ø 209FB400 Fan box In-Line Centrifugal Duct Fans 400mm Ø 209FB500 Fan box In-Line Centrifugal Duct Fans 500mm Ø 209FILTERQPFB100 Spare bag filters 219FILTERQPFB125 Spare bag filters 219FILTERQPFB160 Spare bag filters 219FILTERQPFB200 Spare bag filters 219FILTERQPFB250 Spare bag filters 219FILTERQPFB315 Spare bag filters 219FILTERQPFB400 Spare bag filters 219FILTERS100 Spare panel filters 209FILTERS125160 Spare panel filters 209FILTERS200 Spare panel filters 209FILTERS250 Spare panel filters 209FILTERS315 Spare panel filters 209FILTERS400 Spare panel filters 209LS1000 Louvre Shutter - Size 1000 198LS250 Louvre Shutter - Size 250 198LS315 Louvre Shutter - Size 315 198LS350 Louvre Shutter - Size 350 198LS400 Louvre Shutter - Size 400 198LS450 Louvre Shutter - Size 450 198LS500 Louvre Shutter - Size 500 198LS560 Louvre Shutter - Size 560 198LS630 Louvre Shutter - Size 630 198LS710 Louvre Shutter - Size 710 198LS800 Louvre Shutter - Size 800 198MFZ250 Mounting Feet 250mm Ø 203MFZ315 Mounting Feet 315mm Ø 203MFZ355 Mounting Feet 355mm Ø 203MFZ400 Mounting Feet 400mm Ø 203MFZ450 Mounting Feet 450mm Ø 203MFZ500 Mounting Feet 500mm Ø 203MFZ560 Mounting Feet 560mm Ø 203MFZ630 Mounting Feet 630mm Ø 203MFZ710 Mounting Feet 710mm Ø 203MFZ800 Mounting Feet 800mm Ø 203PA100 Fusible Link Fire Damper 100mm Ø 213PA125 Fusible Link Fire Damper 125mm Ø 213PA160 Fusible Link Fire Damper 160mm Ø 213PA200 Fusible Link Fire Damper 200mm Ø 213PBZ300 Purlin Box 315/355 207PBZ400 Purlin Box 400/450 207PBZ500 Purlin Box 500/560 207PBZ560 Purlin Box 560 207PBZ630 Purlin Box 630 207QAH125 Electric Heaters 125mm Ø 209QAH150 Electric Heaters 150mm Ø 209QAH160 Electric Heaters 160mm Ø 209QAH200 Electric Heaters 200mm Ø 209QAH250 Electric Heaters 250mm Ø 209QAH315 Electric Heaters 315mm Ø 209QAH400 Electric Heaters 400mm Ø 209QP100 Quiet Pack 100mm Ø 210QP125 Quiet Pack 125mm Ø 210QP150 Quiet Pack 150mm Ø 210QP160 Quiet Pack 160mm Ø 210QP200 Quiet Pack 200mm Ø 210QP250 Quiet Pack 250mm Ø 210QP315 Quiet Pack 315mm Ø 210QP400 Quiet Pack 400mm Ø 210QP500 Quiet Pack 500mm Ø 210QPTW100 Quiet Pack Twin Fan 100mm Ø 212QPTW125 Quiet Pack Twin Fan 125mm Ø 212QPTW150 Quiet Pack Twin Fan 150mm Ø 212QPTW160 Quiet Pack Twin Fan 160mm Ø 212QPTW200 Quiet Pack Twin Fan 200mm Ø 212QPTW250 Quiet Pack Twin Fan 250mm Ø 212QPTW315 Quiet Pack Twin Fan 315mm Ø 212QPTW400 Quiet Pack Twin Fan 400mm Ø 212QPTW500 Quiet Pack Twin Fan 500mm Ø 212QSA100/280 100mm Ø 280mm wall sleeve 229QSA125/280 125mm Ø 280mm wall sleeve 229QSA125/80 125mm Ø 80mm wall sleeve 229QSA150/280 150mm Ø 280mm wall sleeve 229QSA200/280 200mm Ø 280mm wall sleeve 229QSA200/80 200mm Ø 80mm wall sleeve 229QSA250/280 250mm Ø 280mm wall sleeve 229W: www.vent-axia.com 241


Stock Reference IndexStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> PageQSA250/80 250mm Ø 80mm wall sleeve 229QSA315/280 315mm Ø 280mm wall sleeve 229QSA315/80 315mm Ø 80mm wall sleeve 229QSA400/280 400mm Ø 280mm wall sleeve 229RAZ3001200 Drop in Curb Attenuator 1200mm 206RAZ300600 Drop in Curb Attenuator 600mm 206RAZ300900 Drop in Curb Attenuator 900mm 206RAZ4001200 Drop in Curb Attenuator 1200mm 206RAZ400600 Drop in Curb Attenuator 600mm 206RAZ400900 Drop in Curb Attenuator 900mm 206RAZ5001200 Drop in Curb Attenuator 1200mm 206RAZ500600 Drop in Curb Attenuator 600mm 206RAZ500900 Drop in Curb Attenuator 900mm 206RAZ6001200 Drop in Curb Attenuator 1200mm 206RAZ600600 Drop in Curb Attenuator 600mm 206RAZ600900 Drop in Curb Attenuator 900mm 206RCZ1000 Roof cowl assembly 206RCZ300 Roof cowl assembly 206RCZ400 Roof cowl assembly 206RCZ500 Roof cowl assembly 206RCZ630 Roof cowl assembly 206RCZ800 Roof cowl assembly 206RD14 Auto Transformer 14Amp, 3 Phase 221RDTK10 Auto Transformer 1Amp, 3 Phase 221RDTK20 Auto Transformer 2Amp, 3 Phase 221RDTK40 Auto Transformer 4Amp, 3 Phase 221RDTK70 Auto Transformer 7Amp, 3 Phase 221RSZ300 Roof Shutter 315/355 207RSZ400 Roof Shutter 400/450 207RSZ500 Roof Shutter 500/560 207RSZ630 Roof Shutter 630/710 207RTRE20 Speed Controller 2Amp, 1 Phase 221RTRE30 Speed Controller 3.5Amp, 1 Phase 221RTRE60 Speed Controller 6Amp, 1 Phase 221RTRE75 Speed Controller 7.5Amp, 1 Phase 221RTRE90 Speed Controller 9Amp, 1 Phase 221SA100/280 Unitex Wall Terminals 100mmØ 280mm Sleeve 229SA100/80 Unitex Wall Terminals 100mmØ 80mm Sleeve 229SA125/280 Unitex Wall Terminals 125mmØ 280mm Sleeve 229SA125/80 Unitex Wall Terminals 125mmØ 80mm Sleeve 229SA150/280 Unitex Wall Terminals 150mmØ 280mm Sleeve 229SA150/80 Unitex Wall Terminals 150mmØ 80mm Sleeve 229SA200/280 Unitex Wall Terminals 200mmØ 280mm Sleeve 229SA200/80 Unitex Wall Terminals 200mmØ 80mm Sleeve 229SA250/280 Unitex Wall Terminals 250mmØ 280mm Sleeve 229SA250/80 Unitex Wall Terminals 250mmØ 80mm Sleeve 229SA315/280 Unitex Wall Terminals 315mmØ 280mm Sleeve 229SA315/80 Unitex Wall Terminals 315mmØ 80mm Sleeve 229SDX100 EuroSeries (SDX) 100mm 218SDX125 EuroSeries (SDX) 125mm 218SDX150 EuroSeries (SDX) 150mm 218SDX150HB EuroSeries (SDX) 100mm - High Performance 218SDX200 EuroSeries (SDX) 200mm 218SDX200HB EuroSeries (SDX) 200mm - High Performance 218SDX250 EuroSeries (SDX) 250mm 218SDX250HB EuroSeries (SDX) 250mm - High Performance 218SDX315 EuroSeries (SDX) 315mm 218SDX315HB EuroSeries (SDX) 315mm - High Performance 218SLP100 Slimpack In-line centrifugal Fan 117SLP125 Slimpack In-line centrifugal Fan 215SLP150 Slimpack In-line centrifugal Fan 215SLP200 Slimpack In-line centrifugal Fan 215SLP250 Slimpack In-line centrifugal Fan 215SLP315 Slimpack In-line centrifugal Fan 215SLPF100 Panel Filters 215SLPF125 Panel Filters 215SLPF150 Panel Filters 215SLPF200 Panel Filters 215SLPF250 Panel Filters 215SLPT200 Slimpack Twin Duct In-line Fan 200mm 217SLPT250 Slimpack Twin Duct In-line Fan 250mm 217SLPT315 Slimpack Twin Duct In-line Fan 315mm 217SLSD100/1 In-line Attenuators 900mm - 100mm Ø 215SLSD125/1 In-line Attenuators 900mm - 125mm Ø 215SLSD150/1 In-line Attenuators 900mm - 150mm Ø 215SLSD200/1 In-line Attenuators 900mm - 200mm Ø 215SLSD250/1 In-line Attenuators 900mm - 250mm Ø 215SLSD315/1 In-line Attenuators 900mm - 315mm Ø 215SLSD100/2 In-line Attenuators 1200mm - 100mm Ø 215SLSD125/2 In-line Attenuators 1200mm - 125mm Ø 215SLSD150/2 In-line Attenuators 1200mm - 150mm Ø 215SLSD200/2 In-line Attenuators 1200mm - 200mm Ø 215SLSD250/2 In-line Attenuators 1200mm - 250mm Ø 215SLSD315/2 In-line Attenuators 1200mm - 315mm Ø 215SLSI100/1 In-line Attenuators 300mm - 100mm Ø 215SLSI125/1 In-line Attenuators 300mm - 125mm Ø 215SLSI150/1 In-line Attenuators 300mm - 150mm Ø 215SLSI200/1 In-line Attenuators 300mm - 200mm Ø 215SLSI250/1 In-line Attenuators 300mm - 250mm Ø 215SLSI315/1 In-line Attenuators 300mm - 315mm Ø 215SLSI100/2 In-line Attenuators 600mm - 100mm Ø 215SLSI125/2 In-line Attenuators 600mm - 125mm Ø 215SLSI150/2 In-line Attenuators 600mm - 150mm Ø 215SLSI200/2 In-line Attenuators 600mm - 200mm Ø 215SLSI250/2 In-line Attenuators 600mm - 250mm Ø 215SLSI315/2 In-line Attenuators 600mm - 315mm Ø 215SP5001 Speed Controller 1Amp, 1 Phase 220SP5010 Speed Controller 10Amp, 1 Phase 220SP5025 Speed Controller 3Amp, 1 Phase 220SP5050 Speed Controller 5Amp, 1 Phase 220SPM5020 Auto Transformer 2Amp, 1 Phase 220SPM5035 Auto Transformer 3.5Amp, 1 Phase 220SPM5060 Auto Transformer 6Amp, 1 Phase 220SPM5075 Auto Transformer 7.5Amp, 1 Phase 220242 T: 0844 856 0590


InformationStock Ref <strong>Product</strong> Page Stock Ref <strong>Product</strong> PageSPM5090 Auto Transformer 9Amp, 1 Phase 220SPM5140 Auto Transformer 14Amp, 1 Phase 220SPTK5050 Speed Controller 5Amp, 1 Phase 220VA54119 Reducer 150 to 125 100Ø 114VHD100 Damper (Supply) Diffuser with Integral fire 100mm Ø 226VHD125 Damper (Supply) Diffuser with Integral fire 125mm Ø 226VHD150 Damper (Supply) Diffuser with Integral fire 150mm Ø 226VHD200 Damper (Supply) Diffuser with Integral fire 200mm Ø 226VHE100 <strong>Vent</strong>ilex Steel <strong>Vent</strong>ilation Valves 100mm Ø 227VHE125 <strong>Vent</strong>ilex Steel <strong>Vent</strong>ilation Valves 125mm Ø 227VHE150 <strong>Vent</strong>ilex Steel <strong>Vent</strong>ilation Valves 150mm Ø 227VHE200 <strong>Vent</strong>ilex Steel <strong>Vent</strong>ilation Valves 200mm Ø 227W10303102M Speed controller 2.5 Amp 138W10554150 T-Series other sizes 150mm 138W10554200 T-Series other sizes 200mm 191W10554250 T-Series other sizes 250mm 191W10554315 T-Series other sizes 315mm 191W14301010 HR500 Controller 185W161110 TX6WW 132W161210 TX6RF 134W161240 TX6DR 136W161510 TX6WL 133W161610 TX6PL 135W161710 TX6IL 137W162110 TX7WW 132W162210 TX7RF 134W162240 TX7DR 136W162510 TX7WL 133W162610 TX7PL 135W163110 TX9WW 132W163210 TX9RF 134W163240 TX9DR 136W163510 TX9WL 133W163610 TX9PL 135W163710 TX9IL 137W164110 TX12WW 132W164210 TX12RF 134W164240 TX12DR 136W164510 TX12WL 133W164610 TX12PL 135W164710 TX12IL 137W300310 1.5A Electronic Controller 177W361119 T-Series Controller Surface mounting 220 - 240V 176W361310 TimeSwitch Controller Surface mounting 176W362320 T-Series Ecotronic Controllers Surface mounting 176W560151 Window/Wall/Ceiling Termination Sets 191W560152 Window/Wall/Ceiling Termination Sets 191W560153 Window/Wall/Ceiling Termination Sets 191W560154 Window/Wall/Ceiling Termination Sets 191W561031 T-Series Adaptor Kits 6” 191W561032 T-Series Adaptor Kits 7” 186W561033 T-Series Adaptor Kits 9” 186W561034 T-Series Adaptor Kits 12” 186W561431 Brown Finish 192W561432 Louvre Grilles 192W561433 Louvre Grilles 192W561434 Louvre Grilles 192W563536 Filtered Inlet Grille 190WA100 100mm Weather Apron (flat roofs) 228WA160 125mm - 160mm Weather Apron (flat roofs) 228WA160/20 Weather Apron (pitched roof) 228WA200 200mm to 250mm‘8’to‘10’ Roof System 228WA200/20 Weather Apron (pitched roof) 228WB160 125mm to 160mm Roof Cowl (Standard Colour) 228WB160C 125mm to 160mm Roof Cowl (Non-standard Colour) 228WB200 200mm to 250mm Roof Cowl (Standard Colour) 228WB200C 200mm to 250mm Roof Cowl (Non-standard Colour) 228WGZ250 Wire Guards 203WGZ315 Wire Guards 203WGZ355 Wire Guards 203WGZ400 Inlet Wire Guard 400mm dia 203WGZ400 Inlet Wire Guard 400mm dia 203WGZ450 Inlet Wire Guard 450mm dia 203WGZ500 Inlet Wire Guard 500mm dia 203WGZ560 Inlet Wire Guard 5600mm dia 203WGZ630 Inlet Wire Guard 630mm dia 203WGZ710 Inlet Wire Guard 710mm dia 203WGZ800 Inlet Wire Guard 800mm dia 203WRC100 100mm ‘4’ Roof System 228W: www.vent-axia.com 243


By Appointment to H.M. The QueenSuppliers of Unit <strong>Vent</strong>ilation Equipment<strong>Vent</strong>-<strong>Axia</strong>, Crawley, West SussexVENT-AXIA CONTACT NUMBERSFree technical, installation and sales advice is availableSales Centre:Domestic & CommercialSales Tel: 0844 856 0590Sales Fax: 01293 565169Tech Support Tel: 0844 856 0594Tech Support Fax: 01293 532814IndustrialSales Tel: 0844 856 0591Sales Fax: 01293 534898Tech Support Tel: 0844 856 0595Tech Support Fax: 01293 532814Web:Email:www.vent-axia.comsales@vent-axia.comSupply & ServiceAll sales made by <strong>Vent</strong>-<strong>Axia</strong> Limited are made only uponthe terms of the Company’s Conditions of Sale, a copy ofwhich may be obtained on request. As part of the policy ofcontinuous product improvement <strong>Vent</strong>-<strong>Axia</strong> reserves the rightto alter specifications without notice.A British company supporting British manufacturing<strong>Vent</strong>-<strong>Axia</strong> Group Ltd Right products, right price, right here!402243/0612

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!