27.11.2012 Views

ENDOPORE® Implant System - Optident

ENDOPORE® Implant System - Optident

ENDOPORE® Implant System - Optident

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ENDOPORE ®<br />

<strong>Implant</strong> <strong>System</strong>


-dimensional<br />

bone ingrowth<br />

Unique Design<br />

The Endopore dental implant incorporates a<br />

unique, truncated cone-shaped design that<br />

uses a multilayered porous surface geometry<br />

over most of its length to achieve integration<br />

by three-dimensional bone ingrowth.<br />

Developed in response to the need for a<br />

simpler, less invasive and biologically more<br />

compliant system, the Endopore implant<br />

employs an approach that has been used<br />

extensively for orthopedic joint replacement<br />

fixation since the mid 1980’s.<br />

Endopore’s surgical advantages include:<br />

• a secure, three-dimensional interlocking interface with bone<br />

• predictable and minimal crestal bone remodelling<br />

• greater surgical options with shorter implant lengths<br />

• an uncomplicated surgical sequence<br />

• minimal instrumentation and inventory<br />

Outstanding Success Rates<br />

Endopore’s high rates of success are due<br />

to the Endopore’s engagement with the<br />

alveolar crest by cortical bone ingrowth into<br />

the implant’s interconnecting pores. When<br />

the implant is placed into function, occlusal<br />

loads transferred to the crest stimulate further<br />

cortical bone development in accordance<br />

with Wolff’s law. In contrast, a screw-type<br />

implant is stabilized only by the alveolar crest’s<br />

superior and inferior bone cortices and, over<br />

most of its length, weak cancellous bone. With<br />

threaded implants, the fixation which occurs<br />

at the bone-implant interface can allow for<br />

rotational movement of the implant.<br />

Bereichsbezeichnung<br />

<strong>Implant</strong> <strong>System</strong><br />

<strong>ENDOPORE®</strong><br />

ENDOPORE ®<br />

BICORTICAL ®


ENDOPORE ®<br />

<strong>Implant</strong> <strong>System</strong><br />

Surgical Kit<br />

Surgical Kit<br />

Conveniently, whether you use the External<br />

Hex or Internal Connection Endopore<br />

implant there is one streamlined surgical kit.<br />

Eliminating the need for an elaborate array of<br />

surgical instrumentation. Making placement<br />

very efficient.<br />

• A comprehensive surgical manual is<br />

included with each surgical kit.<br />

• All burs are quad-fluted resulting in<br />

extremely efficient osteotomy preparation.<br />

• Internally irrigated burs ensure that the<br />

surgical site does not overheat, resulting in<br />

an evenly prepared osteotomy.<br />

• A zirconium nitrate coating on each bur<br />

gives an enhanced cutting edge.


Platform<br />

Diameter<br />

Diameter<br />

Diameter<br />

* TI – Transgingival Collar<br />

ENDOPORE ® <strong>Implant</strong>s<br />

Internal and External Connection<br />

TC*<br />

Length<br />

SCR**<br />

Length<br />

SCR**<br />

Length<br />

** SCR – Smooth Coronal Region<br />

All implants are supplied with a low profile cover screw<br />

<strong>Implant</strong> <strong>System</strong><br />

BICORTICAL ®<br />

<strong>ENDOPORE®</strong><br />

One-Stage: Internal Connection TC Length Item No.<br />

.1 mm diameter 1.8 mm 7 mm 01S-7I1.8<br />

with 4.8 mm platform 1.8 mm 9 mm 01S-9I1.8<br />

1.8 mm 12 mm 01S-12I1.8<br />

.0 mm diameter 1.8 mm 5 mm 01WS-5I1.8<br />

with 4.8 mm platform 1.8 mm 7 mm 01WS-7I1.8<br />

1.8 mm 9 mm 01WS-9I1.8<br />

1.8 mm 12 mm 01WS-12I1.8<br />

Two-Stage: Internal Hex Connection SCR Length Item No.<br />

All implants are supplied with a low profile cover screw<br />

.1 mm diameter 2 mm 7 mm 01l-7I2<br />

2 mm 9 mm 01l-9I2<br />

2 mm 12 mm 01l-12I2<br />

.0 mm diameter 2 mm 7 mm 01Wl-7I2<br />

2 mm 9 mm 01Wl-9I2<br />

2 mm 12 mm 01Wl-12I2<br />

Two-Stage: External Hex Connection SCR Length Item No.<br />

All implants are supplied with a low profile cover screw<br />

. mm diameter 1 mm 9 mm 01M-9I1<br />

.1 mm diameter 1 mm 7 mm 01B-7I1<br />

2 mm 7 mm 01B-7I2<br />

1 mm 9 mm 01B-9I1<br />

2 mm 9 mm 01B-9I2<br />

1 mm 12 mm 01B-12I1<br />

2 mm 12 mm 01B-12I2<br />

.0 mm diameter 1 mm 5 mm 01WB-5I1<br />

1 mm 7 mm 01WB-7I1<br />

2 mm 7 mm 01WB-7I2<br />

1 mm 9 mm 01WB-9I1<br />

2 mm 9 mm 01WB-9I2<br />

1 mm 12 mm 01WB-12I1<br />

2 mm 12 mm 01WB-12I2


ENDOPORE ®<br />

<strong>Implant</strong> <strong>System</strong><br />

Uniform Stress Distribution –<br />

Long-Term Performance<br />

The design of the Endopore implant permits<br />

uniform stress distribution, achieving improved<br />

osseous fixation at the bone-implant interface.<br />

The significant and on-going crestal bone<br />

loss does not occur. In fact, the minimal bone<br />

loss occasionally exhibited in Endopore users<br />

levels off quickly to clinically insignificant<br />

levels, leading to greatly improved long-term<br />

performance.


Eliminate Conventional Sinus Elevations<br />

X-rays are courtesy of Drs. D. Deporter & R. Todescan<br />

Increased Surface Area<br />

X-ray at years in<br />

function<br />

Because the porous design greatly increases<br />

the surface area at the interface between bone<br />

and implant, shorter implants can be used. This<br />

in turn means that Endopore implants can be<br />

used in applications for which much longer<br />

threaded implants would be suitable. With<br />

Endopore, it is often possible to avoid sinus<br />

lifts or other augmentation procedures in the<br />

maxilla and mandible, allowing for less patient<br />

morbidity and for an implant reconstruction<br />

that can be less traumatic and more affordable<br />

for the patient.<br />

Histology<br />

Placed in mm of bone over the Mandibular Canal<br />

<strong>Implant</strong> <strong>System</strong><br />

Clinical radiographic and histological<br />

examinations have demonstrated repeatedly<br />

that, even with shorter implants, shorter<br />

initial healing periods and simpler surgical<br />

techniques than are customary with other<br />

implant designs, the Endopore implant<br />

offers superior fixation performance.<br />

Most importantly, these results have been<br />

demonstrated to be consistent in clinical<br />

settings, where success rates exceed 96%.*<br />

*Data on file.<br />

“This histological section shows the implant and adjacent bone. Bone is directly<br />

apposed to and extending in between the sintered particles on the surface of the<br />

implant. There is no fibrous or inflammatory reaction seen at this interface ...”<br />

*Full report on file.<br />

Dr. Rita A. Kandel<br />

Staff Pathologist<br />

Mount Sinai Hospital<br />

Toronto<br />

BICORTICAL ®<br />

<strong>ENDOPORE®</strong><br />

X-ray at years in<br />

function


ENDOPORE ® <strong>Implant</strong><br />

Manufacturer:<br />

Internal<br />

Connection<br />

Sybron <strong>Implant</strong> Solutions<br />

1717 West Collins Avenue<br />

Orange, California 92867 · USA<br />

www.sybronimplants.com<br />

Distributed by:<br />

Internal Hex External Hex<br />

Sybron <strong>Implant</strong> Solutions GmbH<br />

Julius-Bamberger-Straße 8a · 28279 Bremen · Germany<br />

Phone +49 421 43939-0 · Fax +49 421 443936<br />

www.sybronimplants.de · info@sybronimplants.de<br />

Sybron <strong>Implant</strong> Solutions<br />

A World of <strong>Implant</strong> Solutions<br />

The dental implant platform of Sybron Dental Specialties (SDS)<br />

brings together three (INNOVA – ORALTRONICS – ATTACHMENTS)<br />

organizations that have been leaders in implant manufacturing,<br />

design and development since the inception of implant dentistry.<br />

With our most respected, innovative implant systems – PITT-EASY ® ,<br />

and ENDOPORE ® – we are giving you access to a world of implant<br />

solutions.<br />

09-0104: 11/07

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!