Ease of UseThe Legato 200 seriesoffers unparalleled easeof use through the highresolution color touch screenuser interface. The full touchscreen interface enables theuser to quickly create configurationsand recall them foreasy use. The 4.3" TFT colordisplay with touch pad interfacepresents all the pumpoperating parameters onone easy to view run screen.The New Benchmark for Ease of Use•Displays More Information Simultaneously•Easy to Use and Set up Different Configurations•Intuitive Graphic Interface and Touch screen•International Icons Easy to Use in Any Language•Alarm Indication and Messages•Pump Diagnostic/InformationOptimize Bench SpaceThe Legato Series optimizes the bench space in your lab. Forlimited laboratory space the Legato 200 Series can be placedon its side to reduce the footprint by 4 Times. The displayalso tilts with the change to allow the user operate thepump vertically.HorizontalOrientationIntuitive Run ScreenCombining multiple parameters simultaneously with internationallyrecognizable icons allow the Legato 200 Series to provide a newlevel of intuitive syringe pump operation.Graphic indication of the syringesfilling indicating the volumeFlow Rate is easy to readAll Program settings areindicated on the displayCurrent time anddate is shownVerticalOrientationDisplayRotates 90˚Using gloves is no problem withLegato’s resistive touch screenTotal Volume DeliveredCurrent status of the PumpTotal Remaining Time of the ProgramTotal Elapsed Time of the ProgramFlow Direction with arrow indicatorDead Volume can be quickly eliminatedwith a fast forward featureThe pusher block can also bereleased with a fast reverse feature1 www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.0160 2


Extensive ApplicationsUses of<strong>Syringe</strong> <strong>Pumps</strong>• Calibration• Diluting• Dispensing• Dosing• Emulsification• Fluid Transfer• Infusion of Fluids• Mixing• Perfusion• Timed Delivery• Withdrawal of Fluids• Slow Infusion• VolumetricDispensing• MS Calibration• Microfluidics/MicrofluidicChannel Injections• Surface PlasmaResonance• Biotech Research andDevelopment• Drug Discovery• Neuroscience• Organic Synthesis• Aerosol Injection/Nebulization• Agriculture• Animal Drug/NutrientInjections• Automotive Research• Cell Injections• Chemical Development• Pilot Plant Reactor Dosing• Continuous Flow• Dye Dilution• Dye/Isotope Injection• Electrospinning• Emulsification• Emulsion Polymerization• Entomology• Geological SamplingThe following is an extensivelist of applicationareas in which syringepumps are utilized. Thesuperior performance of <strong>KD</strong>Ssyringe pumps has madethem prominent in publicationsfor their outstandingperformance, smooth flowand rugged design.Bibliographies and publicationsare available at:www.kdscientific.com• Isotope Injections• Liquid ChromatographyInjections• Metered Dispensing• Microdialysis• Micro-Filtration• Perfusion• Pharmaceutical Development• Polymer Research• Post Column Addition• Electrospray (ESI-MS)• HPLC Mass Spec• Lock Mass Infusion/Calibration• MALDI-TOF Matrix Addition• Nano Flow Rates• Precision Mass Spec• Capillary Electrophoresis• Cell Manipulation• Cell Patterning• Cell Separation• Chemical BindingCoefficients• Chemical GradientFormation• Enzyme Reaction Kinetics• Flow Cytometry• Fluid Viscosity• Immunoassays• Reactor Injections• Toxicology Studies• Viscosity/ViscometerSystems• Weather Researchwww.kdscientific.com phone 508.429.6809 fax 508.893.01603


The Legato’s proven syringemechanism design iseasy to use and securelyholds the syringes for smoothflow performance.A Rugged Design with• One touch quick release pusher block is easy to use and isalways engaged.• Advanced mechanical syringe mechanism incorporates a dual purpose,syringe clamp for large syringes, >30 ml to 140 ml, or simply flip thesyringe clamp to hold smaller syringes,


Superior Reliability and PerformanceNo other syringe pumpperforms; like theLegato 200 Series. It offersa broad flow rate rangealong with superior accuracyand repeatability.Advanced Mechanical Design for Superior Flow Performance• Broad Dynamic Flow Range from pl/min to ml/min• Accuracy to 0.35%• Repeatability to 0.05%• Adjustable Linear Force to 35 Kg (75 lbs)• Welded Steel Chassis – the Ultimate in EMI/RFI Protection• Selectable Force for Optimum Stall Detection• Chemically Resistive, Anti-Glare Cover with Gasketed Bezelto Protect the Display• Antisiphon Brackets Prevent Backflow• Solvent Spill Dam Protects Unit from Fluid SpillsLess Vibration& DeformationThe welded steel chassis out-performs the conventional plasticchassis. The chassis provides a rigid platform without deformationunder high pressure. Operation of the pump is quieter and thereis less vibration transferred to the syringes because of thisunique design.Legato’s Superior FlowPerformanceFlow performance is optimized with a small step angle microsteppingmotor that drives a precision lead screw and pusher block.Advanced microstepping techniques are employed to furtherreduce the step angle to eliminate flow pulsation. Legato’saccuracy is +/- 0.35% and has 0.05% reproducibility. A widedynamic flow range from 5 pl/min to 220.97 ml/min can beprogrammed into the pump. Additionally, flow rates are userselectable with engineering units from ml, µl, nl, pl, and hours,minutes and seconds.Legato 200 vs Conventional<strong>Syringe</strong> PumpOptimal EMI/RFI Shieldingwith Welded Steel ChassisThe superior design of the full metal chassis provides noiseisolation and anti-vibration features for increased reliability.All syringe racks are hardened rolled steel and will not deformwith pressure.Chemically ResistiveAnti-Glare CoverProtection of the display is through atransparent anti-glare cover. The spilldam is designed to prevent fluids fromingressing into the sealed display.Flow Rate (nl/min)Time Elapsed (sec)250 µl <strong>Syringe</strong>Legato 200Conventional PumpConventionalPump6www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.01607


Ease of ConfigurationL egato is quick toconfigure; an easy touse screen shows all theparameters in one display.In four quick steps….1Select the Mode2Select the <strong>Syringe</strong> Sizeand Type3Select the Flow Rate4Select the Total Volume tobe delivered or select theTotal TimeFast Experimental Setupand ExecutionStep 3: Wide Flow Rate RangeMinimum and Maximum flow shown for each size of syringe.Setup is Easy with Diagnosticsand Pump InformationSelect the parameters for the configuration and display the pumpinformation. The Diagnostic Pump Information screen shows:• The pump’s parameters, including the calibration andmaintenance dates.• Messages indicating when it is time to recalibrate the unit orwhen it is time for regular maintenance.• Pump software version, calibration, and lubrication intervals.The interface Configuration Screen withsimultaneous display of parameters makesexperimental setup and execution assimple as a touch of the screen.Step 1: Mode SelectionDepending on the model of pump, the unitcan be configured to:- Infuse Only- Withdraw Only- Infuse/Withdraw- Infuse/Withdraw Continuous- Infuse/Withdraw Programmable- Withdraw/Infuse- Withdraw/Infuse Programmable- Define Your Own Custom Programs/RecipesStep 2: Wide Range of <strong>Syringe</strong>sUse any manufacturers’ syringes, from 0.5 µl to 140 ml.Any type of syringe including glass, plastic and stainlesssteel syringes.Step 4: Selectable Target Volume and TimeSelect the total volume from nl to ml. Units are selectable -or for infuse only, select the time.Notifications and Error MessagesNotifications and error messages are displayed for the user toacknowledge, eliminating any guesswork about problems.Legato Features 5 Different Alarms:The pump’s alarm configurability includes alarms for near-end ofrun (user selectable), completion of run, power-up, keypad clicks,stall detection and calibration reminder.• End of Run• Near End of Run• Power Up• Stalled Condition• Calibration Reminder8www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.01609


Ease of ConfigurationFlowRateFlowRateFlowRateFlowRateMultiple users can usethe programmablepump saving their specificconfigurations and recallingthem with a touch of abutton. Also, different testscan be setup and storedfor quick operation. Theprogrammable models offermaximum flexibility andcapability for configuringand running differentprograms/recipes.CONSTANT RATERAMP RATESTEPPED RATEPULSE FLOWTime | VolumeTime | VolumeTime | Volume# Cycles# Steps# PulsesSimple Configuration for Routine & Complex ApplicationsConfigure Custom Programs QuicklyStandard profiles make custom programs easy to setup. If more complexity is needed theuser can select from advanced preprogrammed functions including:- Constant Rate- Ramp- Stepped- PulsePre-defined profiles for easy configuration.• Control the programs through real and relative clock• Easy retrieval of multipleprograms with labels.• Easy flow configuration withpredefined functions suchas ramp, constant rate,pulse, link, start, stop,and elapsed time.• Up to 40 programs of 20 steps each can be configured and stored in theunit; quickly recalling programs with the touch of a button.• Identify programs with a 15-character alphanumeric name for easyidentification. Store custom programs on the computer and download atfuture dates.• Start and stop programs with real time clock or using elapsed timeLinking and activating steps is easy with:Trigger programs with pre-defined options.- Go-To statements- Time Delays- Repeating steps- Linking different programs- Stopping the pump- Triggering the pumps using TTL output- Accepting an event input, such as a usertouch or motor stallIn addition, events can trigger the pump towithdraw or infuse.Organic Syn 12 - Pump 1Flow Rate (pl/hr)8642NUTRIENT A # 6Unique labeling for each program.NAME: ORGANIC SYN 12Infuse for 10 minutes at 2 pl/hr. Stop then, toggle Pump 2 tostart infusing and pump at 8 pl/hr for 50 minutes.Stops5 10 15 20 25 30Time (min)Organic Syn 12 - Pump 2Flow Rate (pl/hr)8642Pump 1Pump 210 20 30 40 50 60Time (min)RECIPE NAME: DRUG 8302Start on December 30 at 12:00 pm. Infuse at1nl/min for 2 hoursevery day at 12:00 pm for 2 days. Then stop.Drug 8302 - Day 1Flow Rate (nl/min)3210.5Drug 8302 - Day 2Flow Rate (nl/min)Nutrient A #6Flow Rate (µl /hr)3210.52015105Starts at12 pm.5 1 1.5 2 2.5 3Time (hrs).5 1 1.5 2 2.5 3Time (hrs)RECIPE NAME: NUTRIENT A #6A test begins at 4 pm and runs at a flow rate of 5 µl/hr for 1hour then goes to 10 µl/hr for 30 minutes. Waits for the user topress the display then continues for 1 more hour ramping from5 µl/hr to 25 µl/hr.25Starts at4 pmWaitsfor userUserpressesdisplay.5 1 1.5 2 2.5 3Time (hrs)Time | Volume10www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.016011


Superior VersatilityEasy external connectionsto a computer or othercontrol devices are throughUSB interface or RS-232 (9pin Dsub). Simple ASCII commandsmake communicationwith the pump easy. Fordirect control of the pumpthe user can use the I/Ointerface. (15 pin Dsub) Pumpdirection can be changed.Two trigger outputs and atrigger input in for externalevents such as a processparameter is available. Thefootswitch input will allowthe control of the pumpthrough an external device.The unit also has an outputfor run indication allowingconnection to a remote light.The Legato’s Versatility isIn Communication — Multi PumpMode of OperationThe pumps are versatile and can be interconnected through the RS-485 interface. Legato 200 models can be mixed and matched in the daisy chain offering maximum flexibility. Upto 99 pumps can be linked together through the RS-485 interface. This interface is easy touse and each pump has its own unique pump address.Computer InferfaceRS-232Second to NoneEnsure the consistency and accuracy ofprograms with the ability to:• export programs to a PC• export a program to another pump• duplicate programs• append one program to another• rename programs• delete programsAA&BMultiple tests are easy torun and control, aswell as gradients, by linkingup to 99 pumps togetherthrough the RS-485 interface.This interface is easy to useand each pump can beassigned its own uniquepump addressAMulti-PumpProgramTransferRemoteStart/StopTTL InterfaceNetwork up to 99<strong>Pumps</strong> with RS-485Daisy ChainBBTransfer programs to a computerRename RecipesStore Configurations for easy recallThe Legato 200 Series pumps permit the daisychaining up to 99 pumps. To facilitate operation inthese modes, the Legato 200 Series applicationsoftware includes a variety of commands designedto simplify the export/import of programs betweenthe pump and external devices.Hands FreeConnectionUpload/<strong>Download</strong>Recipes USB SerialInput (Type B)Direct Motor AdjustmentAnalog Input (Optional)Manipulate programs quickly.Ensure pump topump programconsistencyAdd a configurationto anotherconfigurationDelete configuration12www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.016013


Models and AccessoriesThe Legato 200 Seriesoffers three basic pumpmodels ensuring the rightpump for your application.A Variety of Models toMeet Your RequirementsModular syringe rackscan be purchasedto create a multichannelsyringe pump.• Infuse Only• Infuse and Withdraw• Push/PullThe infuse and withdrawand push/pull pumps areavailable in a programmableversion for maximum flexibilityand capability. Each of thebasic models works with onesyringe or two and canbe reconfigured in the fieldto use multiple syringes.Legato 200Infuse Only<strong>Syringe</strong> PumpLegato 200Infuse Only <strong>Syringe</strong> Pump. Accommodates 2 syringes 0.5 µl to140 ml. User definable flow rates with selectable target volumesor time values to control the total infusion volume.Legato 210Infuse/Withdraw <strong>Syringe</strong> Pump. Accommodates 2 syringes0.5 µl to 140 ml. This unit supports infuse only, withdraw only,infuse/withdraw, withdraw/infuse and continuous mode. Userdefined flow rates with selectable target volumes.Legato 210PThis is a Programmable Legato 210 with user definedconfigurations/programs of up to 800 steps. Up to 40 programsof 20 steps each can be stored in memory.Legato 270Push/Pull <strong>Syringe</strong> Pump. Accommodates 2 syringes for infusionand 2 syringes for withdrawal. This model supports infusion andwithdrawal simultaneously at user defined flow rates and withselectable target volumes to control the total volume pumped.It also supports infuse only, withdraw only, infuse/withdraw,withdraw/infuse and continuous mode. User defined flow rateswith selectable target volumes.Legato 270PThis is a Programmable Legato 270 Push/Pull Pump with 40custom programs of up to 20 steps each. Multiple programs canbe stored in memory.Legato 210 & 210PInfuse/Withdraw<strong>Syringe</strong> PumpLegato 270 & 270PPush/Pull<strong>Syringe</strong> PumpModel Versions78-8200 <strong>KD</strong>S Legato 200 Infuse Only78-8210 <strong>KD</strong>S Legato 210 Infuse/Withdraw78-8212 <strong>KD</strong>S Legato 210P Infuse/Withdraw Programmable78-8270 <strong>KD</strong>S Legato 270 Push/Pull78-8272 <strong>KD</strong>S Legato 270P Push/Pull ProgrammableLarge <strong>Syringe</strong>Multi-Rack 4 x 140 mlSmall <strong>Syringe</strong>Multi-Rack 6/10Microliter<strong>Syringe</strong>Rack•Up to six 10 mlsyringe rack•Up to four 140 mlsyringe rack•Microlitersyringe rackTwo options are availablefor the Legato Series.The analog input optionwhich allows the analog controlof the motor speed. Byapplying a 10 VDC max tothe circuit, the motor speedcan be varied. The secondoption is for an internal fan.This will be factory installed.Large <strong>Syringe</strong> Multi-Rack Option (78-8300)The Large <strong>Syringe</strong> Multi-Rack option will accommodate up to four60 to 140 ml syringes. The field installable rack will work withthe Legato 200, Legato 210 or Legato 210P.Small <strong>Syringe</strong> Multi-Rack Option (78-8301)The Small <strong>Syringe</strong> Multi-Rack option will accommodate up to six30 to 60 ml syringes or up to ten 0.5 µl to 20 ml syringes. Therack will work with the Legato 200, Legato 210 or Legato 210P.Microliter <strong>Syringe</strong> Multi-RackOption (78-8302)The Microliter <strong>Syringe</strong> Multi-Rack Option will accommodate up tofour 0.5 µl to 10 ml syringes. The field installable rack will workwith the Legato 200, Legato 210 or Legato 210P.Model Versions78-8300 Infuse/Withdraw 4 x 140 Multi-Rack(Four 60 to 140 ml syringes) (can be soldfor Infuse Only as well)78-8301 Infuse/Withdraw 6/10 Multi-Rack(Six 30 to 60 ml syringes or ten 0.5 µlto 20 ml syringes) (can be sold for InfuseOnly as well)78-8302 Infuse/Withdraw Microliter Rack(Four 0.5 µl to 10 ml syringes) (can be soldfor Infuse Only as well)14www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.016015


Models and AccessoriesApremier line of stainlesssteel syringes is nowoffered by <strong>KD</strong> <strong>Scientific</strong>.These syringes are a perfectcompliment for the NEWLegato 200 Series. Ruggedstainless steel syringes are anideal solution when the pressuresand the force are high,completely eliminating theproblem of breaking glasssyringes.Stainless steel offers goodresistance to mostaggressive liquids. Wettedparts are #316 stainless steeland Viton or Perfluoroelastomer.<strong>Syringe</strong>s are availablein 2.5, 8, 20, 50 and100 ml sizes with removable,replaceable tips. GenuineSWAGELOK syringe to tubefittings are available in 1/16,1/8 and 1/4 inch sizes. Aluer lock end fitting is alsoavailable. Tips are interchangeablewith all syringesfrom 20 to 100 ml in size.SpecificationsStainless Steel <strong>Syringe</strong>sPremium Line of Stainless Steel <strong>Syringe</strong>s•Compatible with Most <strong>Syringe</strong> <strong>Pumps</strong>•Eliminate Hazards of Glass <strong>Syringe</strong> Breakage•Adaptable to Luer Lock or Swagelok Fittings•Rugged Construction #316 Stainless Steel•Reuseable - Fully Autoclavable•Resistance to Most Chemicals<strong>Syringe</strong> Fitting L3in (mm)2.5 to 8 ml 1/16 0.74 (18.8)2.5 to 8 ml 1/8 0.91 (23.1)20 to 200 ml 1/16 0.67 (17.0)20 to 200 ml 1/8 0.84 (21.3)20 to 200 ml 1/4 0.94 (23.9)20 to 200 ml Luer 1.34 (34.0)0.12 [3.1] 0.12 [3.1]Volume 2.5 ml 8 ml 20 ml 50 ml 100 mlDimensions: in (mm) in (mm) in (mm) in (mm) in (mm)Overall Length of Barrel - (L1) 6.64 (168.7) 6.73 (170.8) 4.73 (120.0) 5.49 (139.3) 6.73 (170.9)L3L1SID I.D.20 ml8 ml2.5 ml50 mlOD O.D.100 mlGlass <strong>Syringe</strong>sPremium Line of Glass <strong>Syringe</strong>s•Easy to clean and maintain•Accurate dispensing•Reusable•Economical•Durable•Chemically resistant•Resistant to thermal shockSpecifications150 ml100 ml50 ml30 ml2 ml20 ml10 ml5 ml<strong>KD</strong> <strong>Scientific</strong> offers a newline of glass syringes tomeet scientific applications inthe laboratory environment.Over ten different sizes ofglass syringes rangingfrom 1.0 ml to 150 mlare available.All syringes are madefrom heat resistantborosilicate glass. Thematerial and construction areresistant to breakage fromshock and sudden temperaturechanges. They are allannealed and tested untilfree of internal strain to withstandrepeated washing.Min. Order Qty. 6 6 6 6 6 6 6 1 1Volume* 1.0 ml 2.0 ml 5.0 ml 10.0 ml 20.0 ml 30.0 ml 50.0 ml 100.0 ml 150.0 mlPiston OutsideDiameter (mm) 4.80 ±0.10 6.45 ±0.10 12.60 ±0.10 15.15 ±0.15 20.40 ±0.20 22.9 ±0.20 27.45 ±0.20 35.90 ±0.25 34.20 ±0.25Piston OutsideDiameter (in) 0.189 ±0.004 0.254 ±0.004 0.496 ±0.004 0.596 ±0.006 0.80 3±0.008 0.902 ±0.008 1.081 ±0.008 1.413 ±0.010 1.346 ±0.010Barrel DiameterOutside (mm) D1 8.30 ±0.20 9.95 ±0.20 15.4 ±0.30 18.35 ±0.35 24.20 ±0.40 27.30 ±0.40 32.35 ±0.55 41.20 ±0.75 39.60 ±0.75Barrel DiameterOutside (in) D1 0.327 ±0.008 0.392 ±0.008 0.606 ±0.012 0.722 ±0.014 0.953 ±0.016 1.075 ±0.016 1.274 ±0.022 1.622 ±0.030 1.559 ±0.030Barrel CollarDiameter (mm) D2 14.95 ±0.50 16.40 ±0.50 22.25 ±0.75 26.20 ±0.75 33.25 ±0.75 37.55 ±0.75 44.00 ±0.75 55.50 ±0.75 52.00 ±0.75Barrel CollarDiameter (in) D2 0.589 ±0.020 0.646 ±0.020 0.876 ±0.030 1.031 ±0.030 1.309 ±0.030 1.478 ±0.030 1.732 ±0.030 2.185 ±0.030 2.047 ±0.030Piston CollarDiameter (mm) D3 11.5 ±0.50 12.25 ±0.75 17.25 ±0.55 19.95 ±0.60 24.65 ±0.65 27.95 ±0.65 34.05 ±0.65 42.05 ±0.65 42.00 ±0.65Piston CollarDiameter (in) D3 0.453 ±0.020 0.482 ±0.030 0.679 ±0.022 0.785 ±0.024 0.97 ±0.026 1.10 ±0.026 1.341±0.026 1.656 ±0.026 1.654 ±0.026Length (mm) L 115.00 ±0.50 115.00 ±0.50 105.00 ±0.50 128.50 ±0.50 145.50 ±0.50 163.00 ±0.50 178.00 ±0.50 215.00 ±0.65 275.00 ±0.65Length (in) L 4.528 ±0.020 4.528 ±0.020 4.134 ±0.020 5.059 ±0.020 5.728 ±0.020 6.417 ±0.020 7.008 ±0.020 8.465 ±0.026 10.827 ±0.026Increment (ml) 0.02 0.05 0.2 0.2 1.0 1.0 2.0 5.0 5.0Stroke - (S) 5.41 (137.4) 4.42 (112.4) 2.74 (69.6) 3.06 (77.83) 4.12 (104.5)Order Code 78-0871 78-0872 78-0873 78-0874 78-0875 78-0876 78-0877 78-0878 78-0879Outside Diameter - (OD) 0.50 (12.7) 0.50 (12.7) 0.88 (22.2) 1.25 (31.8) 1.50 (38.1)Inside Diameter - (ID) 0.191 (4.85) 0.375 (9.525) 0.753 (19.13) 1.126 (28.60) 1.374 (34.90)Maximum Test Pressure 9000 psi 4000 psi 1500 psi 1500 psi 1500 psiWorking Pressure 7000 psi 1500 psi 700 psi 700 psi 700 psiO-Ring Material Standard Balseal Perfluoroelastomer Viton Viton VitonO-Ring Specials (optional) N/A N/A Perfluoroelastomer Perfluoroelastomer PerfluoroelastomerOrder Code <strong>Syringe</strong> with Swagelok 1/16" 78-0801 78-0802 78-0803 78-0804 78-0805Order Code <strong>Syringe</strong> with Swagelok 1/8" N/A 78-0807 78-0808 78-0809 78-0810Order Code <strong>Syringe</strong> with Swagelok 1/4" N/A N/A 78-0812 78-0813 78-0814Order Code <strong>Syringe</strong> with Luer Lock N/A N/A 78-0816 78-0817 78-0818LD1D2Glass PropertiesVolume*±1.5% of rated volumeExpansion Coefficient 52 x 10 -7 /˚CDensity 2.36 g/cm 3 ±0.03 g/cm 3Modulus of Elasticity 64 x 10 3 N/m 2Water ResistanceFirst ClassAcid ResistanceFirst ClassAlkali ResistanceFirst ClassSoftening Point785˚CMelting Temperature 1260˚CStrain Point525˚CAnnealing Point570˚CHardness 7ColorClear16www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.016017


Models and Accessories<strong>KD</strong> <strong>Scientific</strong> offers a newline of disposable PlasticSterile <strong>Syringe</strong>s for all scientificapplications. Available insizes ranging from 1ml to50ml with Luer Lock (LL) orLuer Slip (LS) Tip. Norm-jectsyringes are the ideal solutionfor any situation. Their uniquetwo-part system is latex freeand contains no siliconelubricant or rubber.Our syringes are madefrom laboratory gradepolypropylene and polyethylene.There is no rubber tip onthe plunger making themmore chemically resistantthan rubber tipped syringes.These unique plastic syringeshave a positive safety stop toprevent accidental spills.SpecificationsLuer Lock (Pkg. of 25)Plastic <strong>Syringe</strong>sPremium Line of Glass <strong>Syringe</strong>s•Sterile Packed and Disposable•Compatible with Most <strong>Syringe</strong> <strong>Pumps</strong>•Disposable Substitute for Glass <strong>Syringe</strong>s•No Silicone Lubricant or Rubber•EconomicalVolume (cc) 1 3 5 10 20 30 50Total Length (mm) 94.8 74.9 87 98.5 115.1 132.5 150.0Length ofCylinder (mm) 84.7 65.1 73.8 85.3 102.4 105.2 120.3OutsideDiameter (mm) 6.4 10.8 13.7 17.3 21.55 24.1 30.9InsideDiameter (mm) 4.69 9.65 12.45 15.9 20.05 22.9 29.2NozzleConfiguration Tuberculin Centric Centric Centric Centric Centric CentricOrder Code 78-0850 78-0851 78-0852 78-0853 78-0854 78-0855 78-0856Dose saver design with 0.025 low dead space plug on the piston to minimize waste.The 5 cc has graduations to 6 cc, 10ml has graduations to 12 cc, 20 cc has graduations to 24 cc and 50 cc has graduations to 60 cc.Slip Lock (Pkg. of 25)Volume (cc) 3 5 10 20 30 50Total Length (mm) 74.9 87 98.5 115.1 132.5 150.0Length ofCylinder (mm) 65.1 73.8 85.3 102.4 105.2 120.3OutsideDiameter (mm) 10.8 13.7 17.3 21.55 24.1 30.9InsideDiameter (mm) 9.65 12.45 15.9 20.05 22.9 29.2NozzleConfiguration Centric Centric Eccentric Eccentric Eccentric EccentricOrder Code 78-0857 78-0858 78-0859 78-0860 78-0861 78-0862The 5 cc has graduations to 6 cc, 10ml has graduations to 12 cc, 20 cc has graduations to 24 cc and 50 cc has graduations to 60 cc.Total length is piston thumb rest to syringe tip on an assembled syringe. Cylinder Length is cylinder only, finger grip to tip. The barrel is polypropylene, piston is high density polyethylene.20 cc30 cc10 cc50 cc5 cc3 ccTemperature Controllers• Easy to use• Command temperaturesdigitally set• Ambient to 65°Ctemperature range•Can be powered from 12volt battery for sensitiveelectrophysiologyapplicationsSpecificationsInput Voltage Range 9 to 16 VDCMax. Output Current 1.2 AMax. Output Power 13 WTemperature Ranges (4) Set by DIP Switch: Ambient to +65°CMeter3-Digit LED displayMeter Resolution0.1°CPanel IndicatorsRed: Heat-up ConditionGreen: Heat-down ConditionYellow: Displaying Set-TemperatureFeaturesPushbutton entry of Set-Temperature Set-Temperaturedisplayed for 3 seconds after adjustmentEnclosure Dimensions 2.1 x 6.6 x 11.1 cm (H x W x D)Weight92 gramsWarrantyOne year, parts & laborItem No. Description78-0521 TC-124A, Temperature Controller, 120 VAC US78-0522 TC-124AE, Temperature Controller, 240 VAC Europe78-0523 BAC-1, Battery Adapter Cable•Celsius, Fahrenheit, or Absolute(Kelvin) scales•Analog output for data acquisitionsystems or pen recorders•Dust-proof, splash-proof & batterypowered for use in the field•Compatible with any 10kΩ unicalthermistor•Large easy to read LCD displayTA-29SpecificationsTA-32Temperature Range:Celsius 0 °C to 104 °CFahrenheit 2 °F to 220 °FAbsolute (Kelvin) 256 K to 378 KAccuracy 0.3°C ± 1 digit between 20° to 60°CMeter Resolution0.1 degreesTC-124A•Ambient to 65°Ctemperature range•Can be powered from 12volt battery for sensitiveelectrophysiologyapplications•Large, easy to readLED displaySpecificationsModel TM-3 Three-Scale Thermistor Temperature MonitorTM-3TA-31Input Voltage Range 9 to 16 VDCMax Output Current 1.2 A (per channel)Max Output Power 13 W (per channel)Temperature Ranges (4) Set by DIP switch: ambient to +65CMeter Resolution 0.1 °CDisplayLED, 3 digit, 10 mm (0.4 in) highPanel Indicators:Red: Heat-up conditionGreen: Heat-down conditionYellow: Displaying set-temperature or view temperatureFeaturesPushbutton entry of modes, dust-proof, splash-proof casePhysical Dimensions:Case Size 2.1 x 6.6 x 11.1 cm (H x W x D)Shipping Weight 0.5 kgWarrantyOne year, parts & laborItem No. Description78-0524 TC-144, Temperature Controller Dual78-0523 BAC-1, Battery Adapter CableSpecifications Continued:DisplayLCD, 4 digit, 10 mm (0.4in) highSensor10kΩ Unical ThermistorInput & Output Connectors BNC femaleAnalog Output10 mV/°CPower Requirements9 Volt transistor alkaline battery or supplied AC walladapterPhysical Dimensions:Case Size 2.4 x 7.9 x 12.8 cm (H x W x D)Shipping Weight 0.5 kgWarrantyTwo years, parts & laborItem No. Description78-0525 TM-3, Three-Scale Temperature Monitor78-0526 TM-3, Three-Scale Temperature Monitor 230 VACTC-144Thermistor Options78-0527 TA-29. Bead Thermistor 1 mm Diameter78-0528 TA-31. Probe Thermistor 2 mm Diameter 10 mm LongPlastic Housing78-0529 TA-32, Probe Thermistor 1.63 mm Diameter 32 mm LongStainless Steel Housing18www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.016019


Models and AccessoriesWarmed Platforms for 35 mm Petri Dishes<strong>Syringe</strong> WarmersLegato 200 AccessoriesItem No. Description78-8320 Auto Fill Valve Box Low Pressure78-8321 Auto Fill Valve Box High Pressure78-8303 Anti-Siphon Kit78-8304 RS-485 Pump to Pump Communication, 0.5 m (1.6 ft)Adapter D Sub 15 toTerminal BlockAdapter Digital I/O(15 pin to 9 pin)78-8305 RS-485 Pump to Pump Communication, 2 m (6.6 ft)• Temperature control from 25 to 65 C• Stage adapters for all major brand microscopes• Low Cost Systems availableSpecificationsTemperature Range 25° to 65°CAccuracy±0.1°CFeedback Thermistor Built in Unical 10kΩ at 25°CControllerTC-124A / TC-144 Single and DualChannel ControllersPhysical Dimensions:Warmed Platforms (D x L)Aperture Size (D)WeightCable LengthConnector TypeWarrantyItem No.Description79.4 x 3.2 mm10 mm-WP-10, 16 mm- WP-1650 g2.4 m4 pin Male RJ-22One Year78-0530 WP-10, Warmed Platform 10 mm Aperture78-0531 WP-10D, Warmed Platform 10 mm Aperture78-0532 WP-16, Warmed Platform 16 mm Aperture78-0533 WP-16D, Warmed Platform 16 mm Aperture78-0523 BAC-1, Battery Adapter Cable•Use on a syringe pump or support stand•Accommodates 10, 60 and 140 cc syringes•Scale marking ports permit volume monitoring•Can be powered from 12 volt battery for sensitiveelectrophysiology applicationsItem No.10 cc 60 ccSpecificationsHeater Resistance 18 ΩVoltage Requirement Variable to 12 V maximumTemperature Range Ambient to 65°CTemperature Accuracy ±1°CCable Length2.4 mWarrantyOne yearDescription78-0534 SWS-10, <strong>Syringe</strong> Heater for 10 cc <strong>Syringe</strong>s78-0535 SWS-60, <strong>Syringe</strong> Heater for 60 cc <strong>Syringe</strong>s78-0536 SWS-140, <strong>Syringe</strong> Heater for 140 cc <strong>Syringe</strong>s78-0523 BAC-1, Battery Adapter Cable140 ccModel Weight Length OD ID <strong>Syringe</strong> TypeSWS-10 32.7 g 38.2 mm 22.2 mm 16.2 mm Becton DickinsonSWS-60 76 g 83.7 mm 35.0 mm 29.1 mm Becton DickinsonSWS-140 192 g 109.5 mm 51.0 mm 41.4 mm Monoject78-8306 USB Cable PC to Pump Communication, 2 m (6.6 ft)78-8307 USB Cable PC to Pump Communication, 5 m (16.4 ft)78-8308 RS-232 Cable (9 pin d-sub), 2 m (6.6 ft)78-8309 Line Cord US, 115 VAC78-8310 Line Cord European78-8311 Line Cord UK78-8312 Adapter Digital I/O (15 pin to 9 pin)78-8313 Adapter D Sub 15 to Terminal Block78-0225 Footswitch with Phono Jack Plug78-8314 Adapter for 25 ml, 50 ml, 100 ml HamiltonGastight <strong>Syringe</strong>78-8315 Hex Key78-8316 Lubricant SuperLube, 1 cc78-8324 Protective Shield for displayItem No.Description78-8317 Upgrade Infuse Only to Infuse/Withdraw78-8318 Upgrade Infuse Only to Programmable78-8319 Upgrade Infuse/Withdraw to ProgrammableAdapter for 25 ml, 50 ml, 100 mlHamilton Gastight <strong>Syringe</strong>Analog ControlConnectorLubricant SuperLube, 1 ccReplacementBatteryAnalogControl CableFootswitch withPhono Jack PlugUSB Cable PC to PumpCommunicationItem No. Description78-0500 OS-250, Overflow Sensor System78-0501 Replacement MatsOS-250,OverflowSensor SystemOS-250 - Spill Sensor System•Quick and easy to set up•Peak response with 10 to 75% RH•Compatible w/upright & interverted microscopes•1 year warrantySpecificationsPower Requirements 92-240 VAC, 50/60 Hz, 0.5 VAOperating Humidity 10% to 75%Switched Outlet Current 8 AEnclosure Dimensions 4.6 x 8.2 x 18 cm (H x W x D)Shipping Weight 1.4 kgWarrantyone yearOptionFNAIInternal Fan OptionAnalog Control Input Option (0 to 10 VDC)*78-8322 Analog Control Connector78-8323 Analog Control Cable5146037 Replacement Fuse5155288 Replacement Battery* Only available with 78-8212, 78-8272RS-232 Cable (9 pind-sub), 2mLine Cord UKRS-485 Pump to PumpCommunicationLine Cord US 115 V20 www.kdscientific.com phone 508.429.6809 fax 508.893.0160www.kdscientific.com phone 508.429.6809 fax 508.893.016021


Legato 200 SpecificationsAccuracy ±0.35%Reproducibility ±0.05%<strong>Syringe</strong>s (Min./Max.)0.5 µl / 140 mlSpecificationsAtmospheric Specifications:Operating TemperatureStorage TemperatureHumidity4˚C to 40˚C (40˚F to 104˚F)-10˚C to 70˚C (14˚F to 158˚F)20% to 80% RH,non condensingFlow Rate:Minimum (0.5 µl syringe)Maximum (140 ml syringe)DisplayNon-Volatile MemoryConnectors:RS-232RS-485USBI/O & TTL5 pl/min220.97 ml/min4.3" WQVGA TFT ColorDisplay with TouchpadStores all settings9 pin D-Sub ConnectorIEEE-1394, 6 posType B15 pin D-Sub ConnectorMode of OperationClassificationPollution Degree 1Installation CategorySupplier NameSupplier AddressContinuousClass III<strong>KD</strong> <strong>Scientific</strong>84 October Hill Rd.,Holliston, MA 01746Supplier Phone Number 508.429.6809Regulatory CertificationsCE, UL, CSA, CB Scheme,EU RoHSLinear Force (Max) 34 kg (75 lbs) @ 100%Force SelectionDrive MotorMotor Drive Control1.8° Stepper MotorMicroprocessor with1/16 microsteppingNumber of Microsteps 6,400per one rev. of Lead ScrewStep Rate:MinimumMaximumPusher Travel Rate:MinimumMaximumPowerDimensionsWeight27.5 sec/µstep26 µsec/µstep0.36 µm/min190.80 mm/min100-240 VAC: 50/60 Hz,50 W, 0.5 A fuse8.89 x 25.4 x 27.94 cm(3.5 x 10 x 11 in)4.9 Kg (10.75 lb)22www.kdscientific.com phone 508.429.6809 fax 508.893.0160


<strong>KD</strong> <strong>Scientific</strong> Family of <strong>Pumps</strong>The ALL NEWLegato 200<strong>KD</strong>S 100Single-<strong>Syringe</strong>Infusion Pump<strong>KD</strong>S 900µl OEM Module<strong>KD</strong>S EZflow Product Line<strong>KD</strong>S 910MilliliterOEM Module<strong>KD</strong>S UltraSpense2000<strong>KD</strong>S 200Two-<strong>Syringe</strong>Infusion Pump<strong>KD</strong>S 330EmulsifierPump<strong>KD</strong>S 410High Pressure<strong>Syringe</strong> Pump<strong>KD</strong>S 520VolumeDispenseSystem<strong>KD</strong>S Gemini 88W W W . K D S C I E N T I F I C . C O M<strong>KD</strong>S Pico Pump