Exhibit VI-6FirstEnergy <strong>Pennsylvania</strong> CompaniesNumber of Ampere/Ampere-Demand Meters Installed2004-2010YearMeters Installed2004 602005 2382006 2192007* 5932008* 12009* 02010* 1Total 1,112* Note that the data from 2004 to 2006 are for all three FE-PA Companies andfrom 2007 to 2010 only reflect Penelec installations.Source: Data Request ER-18installed until an outage could be rescheduled 8 for the permanent installation. AlthoughPenelec did not technically meet the requirements of the 2004 Reliability SettlementAgreement, all ampere/ampere-demand meters were installed by June 2010.Staff’s Follow-up Recommendation – None.Prior Recommendation – As a supplement to the existing quarterly reports provided tothe PUC, list and describe remedial actions planned or taken for any circuit that appearson the list of 5% Worst Performing Circuits for one year or more, or in four out of sixquarters.Prior Situation – The 5% worst performing circuits for each of the three FE-PACompanies through 2005 were determined using a Circuit Reliability Index (CRI) whichwas affected by weighted factors including Momentary Average Interruption Frequency9Index (MAIFI) , CAIDI, SAIFI and lock outs where a substation breaker trips andremains open. FirstEnergy reported in 2005 that no circuit on Penn Power was on the5% worst performing feeder list for a year or more. Penelec had nine feeders thatremained on the 5% worst performing circuit list for more than a year and Met-Ed hadthree. BWG believed that it was reasonable for a circuit to be placed on the 5% worstperforming circuit list one quarter and stay on the list for two additional quarters whileremedial action takes place. If the same circuit stays on the list for four quarters or is onthe list for four out of six quarters, then additional action needs to be taken.8 The permanent installation for the final ampere/ampere-demand meter being discussed here required aforced outage to be coordinated at an opportune time with the industrial customer involved.9 MAIFI is the average number of momentary interruptions that a customer would experience during agiven period. A momentary interruption is an outage of less than five minutes in duration.- 41 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!