FAG_iCMD<br />
system like number of control patches per ink key zone, trigger mark<br />
configuration, sheet length, etc.<br />
The iCMD controller manages the auto configuration, such as there can be<br />
removed, added, or replaced one single module (Trigger, Reference head, or<br />
densitometer) without the need of external configuration. A simple RESET of the<br />
system will auto-configure the system. The auto configuration functionality is<br />
essential to enable the customer to replace a faulty module by himself. Errors<br />
during configuration can be avoided and the mean time to repair can be reduce.<br />
The iCMD controller collects trigger data, the reference data, and the measurement<br />
data, evaluates the data, applies a patch recognition and reports sheet number,<br />
press speed, cross speed, cross position, and measurement data to the PC.<br />
One iCMD controller unit can handle two <strong>FLASH</strong> lines, face and back printing<br />
with up to 24 densitometers each.<br />
• The trigger unit finds the measurement position directly on the print without any<br />
angle encoder with an accuracy of 0.1mm on a range of 5xTrigger mark size. This<br />
unit makes the iCMD flexible for the mounting position. The flexibility is essential<br />
for the upgrade business because there are many different types of presses installed<br />
and any press has its optimal measurement position in terms of space, environment<br />
parameters, temperature, wet or dry ink, dust etc. The measurement position on the<br />
sheet on grain can vary absolutely by the sheet length from job to job and ≤ 2mm<br />
during the run of off the press.<br />
The trigger mark can be configured and is part of the control strip over the cross<br />
motion area of the trigger unit.<br />
• The densitometer is a complete unit with 3 ANSI Status I glass interference filters<br />
(430nm, 530nm, 610nm, 20nm width each, black calculated by application of the –<br />
V-lambda curve), with polarisation filter and a 45°/0° geometry. It is conform to<br />
the DIN 16536-2 requirements.<br />
• The reference head is manufactured equal to the Densitometer and has a ceramic<br />
white plaque mounted as measurement patch. It measures the spectral variations of<br />
the flash.<br />
• The <strong>FLASH</strong> unit illuminates via fiber optics the measurement patch triggered by<br />
the Trigger unit.<br />
• The positioning device is composed by a beam with two suspensions, one driven<br />
by a servo motor, one freewheel and a servo motor control device.<br />
• Mechanical parts for mounting and alignment. The parts are developed and<br />
customized by VIPTONIC and need to guarantee a correct alignment inside the<br />
press. The iCMD modules need to be cleaned, replaced etc. by one single operator.<br />
The system is mechanically fail save.<br />
Status: preliminary 24.07.2003 4 / 4 Lukas Pescoller