12.07.2015 Views

Application Note on SF6 gas insulated Switchgear - Reptame

Application Note on SF6 gas insulated Switchgear - Reptame

Application Note on SF6 gas insulated Switchgear - Reptame

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

P.O. Box 26, FIN-00421 Helsinki, FINLANDTel: +358 9 894 91Fax: +358 9 8949 2485Email: industrialsales@vaisala.comwww.vaisala.com1 (2)Dewpoint measurementin SF 6 <strong>gas</strong>-<strong>insulated</strong>switchgearSulfur Hexafluoride (SF 6 ) is an inertinsulating <strong>gas</strong> of high dielectric strength andthermal stability. The electric power industryuses SF 6 to insulate high voltage lines, circuitbreakers and other equipment used inelectricity transmissi<strong>on</strong> and distributi<strong>on</strong>.Dewpoint measurement is an important partof SF 6 equipment maintenance.SF 6 is a greenhouse <strong>gas</strong>, with a globalwarming potential 23900 times that of CO 2 .For this reas<strong>on</strong>, the <strong>gas</strong> is used sparingly andrecycled.Moisture in SF 6Power switching or load current interrupti<strong>on</strong> in aswitchgear results in arcing between two c<strong>on</strong>tact points.The insulati<strong>on</strong> properties of SF 6 c<strong>on</strong>trol effectively the arcformati<strong>on</strong>. Under the influence of an arc, a small porti<strong>on</strong> ofSF 6 <strong>gas</strong> dissociates into its atomic c<strong>on</strong>stituents sulfur andfluorine, then again recombining naturally into SF 6 .However, in the presence of moisture, the SF 6 reformati<strong>on</strong>is disturbed and sec<strong>on</strong>dary decompositi<strong>on</strong> products such ashighly corrosive hydrogen fluoride (HF) start to form.These weaken the insulati<strong>on</strong> properties of SF 6 and maycause rapid deteriorati<strong>on</strong> of a high-voltage switchgear.In order to avoid the formati<strong>on</strong> of unwanted sec<strong>on</strong>darydecompositi<strong>on</strong> products, the amount of water vapor in thesystem should be kept at minimum.Operating envir<strong>on</strong>mentA typical dewpoint range for servicing the SF 6 equipmentis -50...-20 °C. Pure SF 6 may be even drier. The mosttypical operating pressure within the switchgears is 3...8barg, but dewpoint measurement can also be performed atatmospheric pressure.The industry also uses ppm units, especially ppm w (partsper milli<strong>on</strong> by weight) to indicate humidity. For SF 6 , thec<strong>on</strong>versi<strong>on</strong> between ppm v and ppm w isppm w = ppm v / 8.1Performing the measurementTypically, dewpoint measurement in the switchgear isd<strong>on</strong>e at 5-8 years intervals by specialized SF 6 servicingcompanies.The measurement can either be performed at system oratmospheric pressure. The c<strong>on</strong>venti<strong>on</strong>al dewpointmeasurement technique (chilled mirror) has typically beenrestricted to measurement at atmospheric pressure due torather high liquefacti<strong>on</strong> temperatures of pressurized SF 6 .


P.O. Box 26, FIN-00421 Helsinki, FINLANDTel: +358 9 894 91Fax: +358 9 8949 2485Email: industrialsales@vaisala.comwww.vaisala.com2 (2)StandardsIEEE standard guides for moisture measurement andc<strong>on</strong>trol in SF 6 Gas-Insulated Equipment (IEEE std 1125-1993).Internati<strong>on</strong>al standards specify the recommendedmaximum moisture c<strong>on</strong>tent in circuit breakers.IEC 376 specifies the limit for new <strong>gas</strong>es to be introducedinto the GIE compartment as 120 ppm v / T d = -40 °C.The US standard ASTM D2472-92 states 71 ppm v / T d =-45 °C.Pure SF 6 c<strong>on</strong>tains very little moisture. A typical moisturelimit set by <strong>SF6</strong> <strong>gas</strong> manufacturers is -60 °C T d .Moisture limit recommendati<strong>on</strong>s of the <strong>gas</strong>-<strong>insulated</strong>equipment (GIE) vary between 70 ... 810 ppm v ,corresp<strong>on</strong>ding to -45 ... -22 °C T d in the atmosphericpressure, or -29 ... -3 °C T d in 5 bar g pressure.enables measurement at both <strong>gas</strong> system and atmosphericpressure. The sampling cells also enable collecting andrecycling SF 6 when measuring in atmospheric pressure.Regardless of dewpoint measurement technology, it is tobe noted, that SF 6 combusti<strong>on</strong> <strong>gas</strong>es such as HF should notbe present when making the measurement. The industrystandard is typically to ensure these <strong>gas</strong>es are not presentin notable quantities before performing dewpointmeasurement. In a well serviced switchgear, the presenceof HF is very rare. Combusti<strong>on</strong> <strong>gas</strong>es may appear in placeswhere the gear is heavily burdened and short circuitscomm<strong>on</strong>ly take place.Products for measuring dewpoint inSF 6The Vaisala DRYCAP ® Hand-held Dewpoint MeterDM70 with the DMP74C probe is optimized formeasuring the dewpoint in SF 6 <strong>gas</strong>. The sensor purgefeature of DM70 allows fast resp<strong>on</strong>se in low dewpoints,and <strong>on</strong>ly a small amount of SF 6 is needed for sampling.Fast resp<strong>on</strong>se time is especially important because of theenvir<strong>on</strong>mental restricti<strong>on</strong>s <strong>on</strong> SF 6 release to atmosphere.The instrument outputs several measurement quantities,including e.g. dewpoint temperature, ppm w , ppm v , andeven dewpoint temperature calculated from <strong>gas</strong> pressureto atmospheric pressure.A 10m extensi<strong>on</strong> cable between the MI70 indicator and theDMP74C probe is useful for measurement points thatlocate high up from ground level.The DSC74B and DSC74C sampling cells are optimizedfor measurement in the SF 6 <strong>gas</strong> <strong>insulated</strong> equipment, and it

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!