Part 1. GeneralOkalux® <strong>Plus</strong> <strong>Light</strong> <strong>Diffusing</strong> <strong>Insulated</strong> <strong>Glass</strong><strong>Specifications</strong>1.01 Summary1.01.1 Okalux® <strong>Plus</strong> light diffusing insulated glass with capillary slab andglass fiber tissue is provided by SCHOTT North America, Inc.1.02 Submittals1.02.1 Product Data: Manufacturer’s catalogs and technical literatureshowing performance properties and recommended installationprocedures.1.02.2 Submit minimum 8” x 11” samples of Okalux® <strong>Plus</strong> light diffusinginsulating glass as required.1.03 Delivery, Storage, and Handling1.03.1 Deliver Okalux® <strong>Plus</strong> light diffusing glass in manufacturer’s originalpackaging.1.04. Warranty1.04.1 Provide a 10-year warranty to include the provision of replacementinsulated glass units which exhibit moisture or other substances on eitherof the inner glass surfaces caused by a failure of the hermetic seal that isnot attributed to glass breakage, improper installation or cleaning andmaintenance contrary to the manufacturer’s written instructions.Part 2. Product2.01 Manufacturer: North American Distribution:Okalux GmbHSCHOTT North America, Inc.Am Jöspershecklein 1555 Taxter Rd.97828 Marktheidenfeld Elmsford, NY 10523Germany Tel: 914 831-2243Fax: 914 831-2346bruce.sparrow@us.schott.com2.02 Materials2.02.1 Description of ProductOkalux® <strong>Plus</strong> light diffusing insulating glass with capillary slab and glassfiber tissue.


2.02.2 <strong>Glass</strong> Make-UpOuter pane: ___ mm tempered or heat strengthened float glass withInterpane I <strong>Plus</strong> e low-e coating on surface #2 (or other coating asagreed).Cavity: 16 mm with 8 mm _____ (air, argon or krypton) filled cavity and 8mm PMMA acrylic UV stable capillary slab encased in fiber tissue.Capillaries are not to exceed 3 mm diameter to assure properdiffusion.Inner pane: ___ mm tempered, heat strengthened or laminated float glasswith 1.50 mm PVB interlayer.Sealant:Dual sealed units:Primary sealant: PolyisobutyleneSecondary sealant: Polysulfide (Capped Systems for framedglazing)Silicone (Uncapped systems for structural glazing)Note: Silicone secondary sealants are notavailable with argon or krypton filled units due tomuch higher gas loss rates.Calculations: <strong>Glass</strong> make-up and thickness to be confirmed by glazing contractorand façade engineer to meet project load and local coderequirements.Size:Okalux® <strong>Plus</strong>, when supplied without a white inner mullion,has a maximum dimension of 1220 mm x 3500 mm. Whenboth of the dimensions exceed 1220 mm, a white innermullion is required to stabilize the capillary slab within theinsulated unit. Maximum dimensions with the white innermullion are 2000 mm x 3500 mm.2.02.3 Performance ValuesOkalux® light diffusing glass insulating glass shall perform optically andthermally based upon the following:<strong>Light</strong> Transmission ________45% maximumSHGC (TSET)________0.38 maximumU-value ________air 0.28; argon 0.24; krypton 0.18(Btu/hr/sf/°F)


Part 3. Execution3.013.01.1 ExaminationThe glazing contractor shall examine the framing and glazing channelsurfaces and backing as well as the conditions under which the glazing isto be performed. The glazing contractor shall also inspect each Okalux®<strong>Plus</strong> unit prior to installation. Any units deemed to be damaged or ofquestionable quality should be brought to the attention of the supplier,SCHOTT North America, Inc, immediately and prior to installation.3.01.2 GlazingOkalux® <strong>Plus</strong> light diffusing insulating glass should be installed inaccordance with the general rules applicable for insulating glass. Theglazing plane support system must be free of any internal obstructions andstructurally adequate for the application.3.01.3 InstallationAs with any insulated glass, the dimensions of units used are limited bythe type, thickness of glass and project load requirements.August 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!