12.07.2015 Views

SPECIFICATIONS ACCESSORIES - Air Techniques, Inc.

SPECIFICATIONS ACCESSORIES - Air Techniques, Inc.

SPECIFICATIONS ACCESSORIES - Air Techniques, Inc.

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SPECIFICATIONS</strong><strong>ACCESSORIES</strong>ScanX Classic (PN F3700)Dimensions: 24.5” H x 15.5” W x 15.5” D(62.2cm H x 39.4cm W x 39.4cm D)Weight: 55 lbs. (25 Kg)ALL-NEWResolution: Up to 22 lp/mmTheoretical Resolution: 40 lp/mm (2000 dpi)Port: USBImaging Medium: Phosphor Storage Plates;Intraoral sizes 0, 1, 2, 3, 4; Panoramic sizes 5” x 12”and 6” x 12” (12.7 cm x 30.5 cm and 15.2 cm x 30.5 cm);Cephalometric size 8” x 10” and TMJ size 5” x 7”(20.3 cm x 25.4 cm and 12.7 cm x 17.8 cm)ScanX IO (PN F3600)Dimensions: 16” H x 15.5” W x 15.5” D(40.6cm H x 39.4cm W x 39.4cm D)Weight: 50 lbs. (22.3 Kg)Resolution: Up to 22 lp/mmTheoretical Resolution: 40 lp/mm (2000 dpi)Port: USBImaging Medium: Phosphor Storage Plates,Intraoral sizes 0, 1, 2, 3, 4Extraoral Phosphor Storage PlatesPanoramic Size 5” x 12”, PN 73578-5, Qty. 1Panoramic Size 6” x 12” (15cm x 30cm), PN 73578-6, Qty. 1Cephalometric Size 8” x 10”, PN 73578-8, Qty. 1TMJ 5” x 7”, PN 73578-57, Qty. 1Intraoral Phosphor Storage PlatesSize 0, PN 73445-0, Qty. 2Size 1, PN 73445-1, Qty. 2Size 2, PN 73445-2, Qty. 4Size 3, PN 73445-3, Qty. 2Size 4, PN 73445-4, Qty. 1For over 50 years, <strong>Air</strong> <strong>Techniques</strong> has been a leading innovator and manufacturer of dental products.Our priority is ensuring complete satisfaction by manufacturing reliable products and providing excellentcustomer and technical support. Whether the need is merchandise, digital imaging or utility roomequipment, <strong>Air</strong> <strong>Techniques</strong> can provide the solution via our network of authorized professional dealers.Proudly designed, tested and manufactured in the United States, our products are helpingdental professionals take their practices to the next level.<strong>Air</strong> <strong>Techniques</strong>' products are distributed through authorized dealers only.Available in all sizes (0, 1, 2, 3 and 4);PAN, CEPH and TMJIMAGINGUTILITY ROOMMERCHANDISEDIGITAL IMAGING WITHOUT LIMITSYOUR COMPLETE DIGITAL X-RAY SOLUTION.WIRELESS. FLEXIBLE. EVERY IMAGE SIZE.ScanX Duo (PN D1000F)Dimensions: 12” H x 10” W x 10.375” D(30.48cm H x 25.4cm W x 26.352cm D)Weight: 21 lbs. (9.5 Kg)Resolution: Up to 22 lp/mmTheoretical Resolution: 40 lp/mm (2000 dpi)Port: USBImaging Medium: Two processing slots acceptPhosphor Storage Plates, Intraoral sizes 0, 1, 2, 3, 4Go to http://www.airtechniques.comfor included accessories and computer requirements.Patented, Easy-Open Barrier EnvelopesSize 0, PN 73248-0, Qty. 100Size 1, PN 73248-1, Qty. 100Size 2, PN 73248-2, Qty. 300Size 3, PN 73248-3, Qty. 100Size 4, PN 73248-4, Qty. 50www.airtechniques.comScanX Cleaning SheetsPlates GuidesPSP Cleaning WipesPlate Transfer BoxPN B2010, Qty. 12PN B2020, Qty. 25PN B3010, Qty. 12PN B3020, Qty. 25PN D1010, Qty. 12PN D1020, Qty. 25Size 0, PN 73566-0, Qty. 1Size 1, PN 73566-1, Qty. 1Size 2, PN 73566-2, Qty. 1Size 3, PN 73566-3, Qty. 1Size 4, PN 73566-4, Qty. 1PN B8910, Box of 50PN 73470, Qty. 1www.airtechniques.comDigital Imaging Without LimitsScan QR Code to learnmore about ScanXPN 9922-363 Rev. F


DESIGNNew body. Faster engine.Dressed in white and a polished silver trim, the new ScanX brings a breathof fresh air into your office. The 3.5” x 5.5” LED display shines blue whenthe system is ready for use, and changes to an amber glow while reading theplates. ScanX delivers a full mouth series of images in just a couple of minutes.VERSATILITYMade for every patient.The ScanX Classic works with all 8 image sizes: 0, 1, 2, 3, 4, PAN, CEPH and TMJ.NEW BODY. FASTER ENGINE. BRILLIANT CHOICE.WORKFLOWLess work and more flow.The choice has never been clearer—with ScanX, you’llhave no need for chemicals, processors, dark rooms andchemistry storage. You’ll benefit from just how quicklyScanX delivers digital images compared to the seeminglyendless wait with film.CLARITYAchieve the highest image quality.Our resolution is simple — deliver the best images for you to do your best work.With a stunning 22 line pairs/mm — and 1,100 dots per inch — ScanX packs inall the details to aid your diagnosis.12123ScanXFull Mouth SeriesFilmFull Mouth SeriesDIGITAL: DRAMATIC ADVANTAGES OVER FILM.• Faster image development. A full-mouth series can take 6 to 12 minutes to process with traditionalfilm, compared to less than 2 minutes to scan with ScanX.• Better clarity. Image resolution with digital is clearer than with film.• Greater convenience. Your staff doesn’t have the hassle of cleaning a chemical processor.• Freed-up space. Free up the space you’re devoting now to a darkroom and chemistry storage.• No costly chemicals. Going digital means no more writing checks for chemicals.• Paperless efficiency. Digital filing and retrieval of patient records mean big time savings andimprovements in accuracy.TWO DIGITAL OPTIONS1) Direct: sensorsA hard, plastic-encased CCD or CMOS chip is attached to a wire that connects directly to a computer’sUSB port. The sensor is placed in the patient’s mouth (using large, nontraditional film holders) and exposedto radiation. Data is immediately transmitted via direct connection to the computer.2) Indirect: PSP (photo-stimuable phosphor) platesA wireless, soft, reusable plate is placed in a protective barrier. The PSP is placed in the patient’s mouth(using traditional film holders for intraoral radiographs or into the panoramic cassette for extraoralradiographs) and exposed to radiation. Then the PSP is placed in the scanning device and data isimmediately transmitted to the computer.BW2PanoramicCephalometricPSP IS THE ONLY DIGITAL OPTION THAT WORKS WITH ALL IMAGE SIZESSize 0 Size 1 Size 2 Size 3 Size 4 Pan Ceph TMJScanX DuoCapable of reading imagessimultaneously from 2 PSPimaging plates, ScanX Duois the ultraportable intraoraldevice.ScanX IOScanX IO is the centralizedintraoral workhorse capable ofreading images simultaneouslyfrom 4 PSP imaging plates.COMFORTWafer–thin PSP imaging plates.ScanX reads images stored on photo stimulable phosphorstorage plates (PSP), which are perfectly shaped for patientcomfort. With rounded corners, and 10 times thinner than hardsensors, our PSP imaging plates are always comfortable—forchildren and adults.ScanX ClassicWith the ability to read imagesfrom all intraoral PSP imagingplates and extraoral PAN, Cephand TMJ imaging plates, ScanXClassic is the do–everything anytime device.IntraoralPROFITABILITYThe top choice for your bottom line.Going digital doesn’t need to be hard.With sensors, you worry about payingreplacement insurance. You possiblyneed to upgrade your PAN and there’salways the risk of downtime from anuncomfortable hard sensor. ScanX comeswith a 24 month, worry–free warranty anduses PSP imaging plates that you can reusethousands of times.$112,500$75,000$37,500ScanXHardwareTotal Cost Over 5 YearsFilmMaterial,Insurance CostsSensorDigital PanScanX can save you $60,000+ over 5 yearsDirect (sensor)Indirect (PSP)*** ** ***Overall dimension is larger than a traditional size 0. **ScanX Classic. *Direct sensor size 0 is NOT the same as film.CAN SENSORS AND PSP BOTH BE USED?Absolutely! Many practices pair PSP imaging with sensor imaging for an all-digital “hybrid” setup.Sensors can be used for image sizes 0, 1 and 2 when chairside images are needed instantly,and PSP can be used for all other cases.SCANX: THE UNDISPUTED LEADER IN PSP DIGITAL IMAGINGWith ratings of 5+ from THE DENTAL ADVISOR and Excellent from Clinicians Report ® ,*nearly 50,000 ScanX devices have been installed worldwide.*Clinicians Report® is an independent, non-profit, dental education and product testing foundation.For the full report featured in September 2011, go to www.cliniciansreport.org.Digital Imaging Without Limitswww.airtechniques.comwww.airtechniques.comwww.airtechniques.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!