<strong>MC</strong> <strong>Cyble</strong>Residential Multi-jet Meter - DN15 & DN20The <strong>MC</strong> <strong>Cyble</strong> is an excellent multi-jet turbine water meter, ready for automated meteringreading (AMR).Following the increasing need of automation in the metering application, <strong>MC</strong> <strong>Cyble</strong> has beendeveloped in order to provide very good and durable metrology performance combined with fully AMRcapabilities.FEATURES AND BENEFITS» Pre-equipped» Anti fraud register» Reliability» RobustnessCommunicationPre-equipped register that enables theuse of <strong>Cyble</strong> communicating modules.At anytime the <strong>Cyble</strong> modules can beeasily mounted, making it a powerfulcommunicating device for several AMRsystems:» Radio walk-by systems» Radio fi xed data collection» M-bus wired systems» Any other system based on pulseoutputsTechnologyEquipped with very robust hydrauliccomponents combined with an extra-dryregister and a magnetic transmission. Itresults in durable and reliable metrologyperformance.Metrology Performance<strong>MC</strong> <strong>Cyble</strong> is approved and manufacturedaccording the new Directive 2004-22-CE(MID) in the following metrological classes:1,6 R100 (and lower) for DN152,5 R100 (and lower) for DN20Anti Fraud Features» Copper Can <strong>Cyble</strong> Register» Exclusive and patented Anti Fraud 3GCover» Protection Against Magnetic TamperingMain Characteristics» Enhanced design and technologiescombining high performance with longtermreliability» High quality engineering materials» Register can be oriented to allow easyreading» 100% of the products are calibrated onelectronic test benches» All calibration results can be providedWATERknowledge to shape your future


Anti Fraud 3G SystemIt consists in a red ring placed underthe cover. The cover can not bedisassembled without breaking it, soany tentative of opening the meter, itscover gets broken and the red ring caneasily be viewed.That alerts and identifi es the fraudattempts.RegistersIt is made with a copper case and glass lens,hermetically sealed it is resistant againstcondensation and also water proof(IP68). As anoption, it is available plastic version (IP67).It is equipped with the <strong>Cyble</strong> target, that allows themounting of any <strong>Cyble</strong> module.Magnetic ShieldExclusive magnetic shield that protectsthe meter against fraud attempts usingexternal magnets.Magnetic TransmissionThe transmissionbetween the turbineand extra-dry register isachieved by magneticcoupling ensuring aprecise and reliablemetering.Robust BodyHigh pressure resistance.Compact and easy handling.CYBLE MODULE FIXATIONThe <strong>Cyble</strong> modules are mounted on the top of the register, its fi xation is secured trough4 different points, including a screw that is sealed. That assures reliability and securityfor AMR.


ADAPTABILITYThe <strong>MC</strong> <strong>Cyble</strong> can be equipped with <strong>Cyble</strong> modules, becoming a remote readinginterface.Benefi ts & Characteristics:» Fast reading and generate bill» Leak detection» Reverse fl ow detection» Fraud detection» Study of customers habits» Reliability» Immune to magnetic fraud» Field tested for over 5 yearsHandheld for walk-by system<strong>Cyble</strong> RF<strong>Cyble</strong> Sensor<strong>Cyble</strong> PulseTYPICAL CURVE <strong>MC</strong> CYBLERadio drive-by system864DN 15MID 1,6 R10020-2-4-6-810 100 Q (l/h) 1000Q1 = 16 l/hQ4 = 2.000 l/hQ3 = 1.600 l/hQmax = 3.000 l/h1000086420DN 20MID 2,5 R100<strong>MC</strong> <strong>Cyble</strong> equipped withAnyQuest <strong>Cyble</strong>-2-4-6-810 100 Q (l/h) 1000Q1 = 25 l/h10000Qmax = 5.000 l/hQ4 = 3.125 l/hQ3 = 2.500 l/h


Technical CharacteristicsNominal diameter (DN) mm 15 20Meter thread inches ½” ¾”Body Lenghts mm 145 - 165 - 170 190MID Model Approval LNE 17401Metrology Class (MID) 1.6 R100 1.6 R31.5 2.5 R100 2.5 R31.5Installing positions H All H AllMinimum Flow Rate Q1 L/h 16 51 25 79Transitional Flow Rate Q2 L/h 26 81 40 127Permanent Flow Rate Q3 m 3 /h 1.6 1.6 2.5 2.5Overload Flow Rate Q4 m 3 /h 2.0 2.0 3.1 3.1Maximum allowedfl ow-rateQmax m 3 /h 3.0 3.0 5.0 5.0Typical starting fl ow rate L/h 7 12Maximum admissiblepressure (MAP)bar 16Pressure loss class at Q3 bar 0.63Pressure loss at Qmax bar < 1Temperature classT50Flow profi le sensitivity classUo / DoMaximum reading m 3 99.999Minimum scale interval L 0.02DimensionsNominal diameter (DN) mm 15 20inches ½” ¾”Weight Kg 1.0 1.2Threads mm G ¾” G 1”A mm 145 - 170 190B mm 80 80C mm 112 112D mm 88 88E mm 147 147DimensionsOur company is the world’s leading provider of smart metering, data collection and utility software systems, with over8,000 utilities worldwide relying on our technology to optimize the delivery and use of energy and water.To realize your smarter energy and water future, start here: www.itron.comFor more information, contact your local sales representative or agency:ITRON WATER METERINGStrada Valcossera, 1614100 AstiItalyPhone: +39 0141 477077Fax: +39 0141 477177While <strong>Itron</strong> strives to make the content of its marketing materials as timely and accurate as possible, <strong>Itron</strong> makes no claims, promises, or guarantees about the accuracy, completeness,or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited tothe warranties of non-infringement of third party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials.© Copyright 2011, <strong>Itron</strong>. All rights reserved. WA-0025.3-EN-11.11