8843 and 8854 Photoelectric Smoke Detectors - Siemens Building ...

8843 and 8854 Photoelectric Smoke Detectors - Siemens Building ...

8843 and 8854 Photoelectric Smoke Detectors - Siemens Building ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The <strong>8854</strong> utilizes the low-profile 8853 surfacemounting base which may be used with a 4 inchsquare or octagonal box, as well as a single-gangelectrical box. The <strong>8854</strong> has screw clamp terminalsfor easy wiring. The base has an optional concealedlocking device to prevent unauthorizeddetector removal.The <strong>8854</strong> is capable of operating both a remotelamp <strong>and</strong> a relay or audible base when used withLifeWatch-450 control panel, other panels will allowone accessory per detector. The 8848 Remote Sensitivity<strong>and</strong> Alarm indicator duplicates the multicolorLED of the detector at a remote location to indicatenormal operation (green), trouble or out of sensitivity(amber), or alarm (red) for detectors located in out ofthe way places such as duct detectors, under computerroom floors, or above suspended ceilings. The8849 is simply a remote red LED to indicate an alarmcondition of a detector.The <strong>8843</strong> <strong>and</strong> <strong>8854</strong> <strong>and</strong> all of the above listedaccessories are UL <strong>and</strong> ULC listed, <strong>and</strong> approvedby CSFM <strong>and</strong> NYMEA, <strong>and</strong> other local boardswhere applicable.Application DataThe <strong>8843</strong> <strong>and</strong> <strong>8854</strong> is fully compatible with otherFaraday low voltage detectors <strong>and</strong> may be intermixedon the same conventional zone circuit. The<strong>8843</strong> <strong>and</strong> <strong>8854</strong> are applicable to the 30 foot spacing(900 sq. ft.) as referred to in the National FireProtection Association St<strong>and</strong>ard 72. This detectorspacing, however, is based on ideal conditions <strong>and</strong>should be used only as a guide in planning detectorlayout. Do not mount detectors close to ventilationor air conditioning outlets that may movesmoke away from the detector. Exposed joists orceiling beams may also effect safe positioning ofsmoke detectors. It is m<strong>and</strong>atory that engineeringjudgement be applied regarding detector placement<strong>and</strong> spacing.Detector CleaningThe detector is field cleanable by twisting thedetector out of the base, unsnapping the chamberfrom the outer cover, without affecting sensitivecalibration <strong>and</strong> cleaning or replacing the removablechamber labyrinth <strong>and</strong> bug screen.Architect <strong>and</strong> Engineer SpecificationsThe photoelectric smoke detector shall be a plug-inunit which mounts to a twist/in base <strong>and</strong> shall beUL listed.The smoke detector shall operate on a two-wirecircuit <strong>and</strong> shall contain a multicolor LED indicatorindicating the detector is operational by flashinggreen, trouble by flashing amber, <strong>and</strong> alarm byflashing red. The detector shall be continually selftesting with visual operation indication <strong>and</strong> notrequire additional hardware or contact with thedetector for testing purposes.The detector shall allow for easy cleaning orreplacement of screens <strong>and</strong>/or chamber componentswithout affecting calibration.The base assembly into which the detector isinstalled shall be a twist/in design with screwclamp terminals. A security lock shall be installedin those areas where tamper resistant installation isrequired as indicated in the drawings.The detector or group of detectors shall require atwo-wire circuit of #18 AWG thermoplastic fixturewire enclosed in conduit, or #18 AWG limitedenergy shielded cable without conduit, if permittedby local building codes. All wiring shall be approvedfor fire alarm use <strong>and</strong> in compliance withnational <strong>and</strong> local codes. When required, the smokedetector shall contain a 135°F fixed temperatureself restoring heat sensor. Actuation of this deviceshall lock the detector alarm circuit.The detector shall be Faraday Model <strong>8854</strong> or Model<strong>8843</strong> with a 8853 surface mounting base.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!