MI Heating Cable - Pentair Thermal Controls
MI Heating Cable - Pentair Thermal Controls
MI Heating Cable - Pentair Thermal Controls
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Design A Design B<br />
Design D<br />
Heated<br />
length<br />
Design A: Single conductor cable (61 series only) Design B: Single conductor cable (61 series only)<br />
Heated<br />
length<br />
PyroFLX (End A)<br />
PyroFLX (End A)<br />
Design D: Dual conductor cable (32, 62 series only) Design E: Dual conductor cable (32, 62 series only)<br />
<strong>MI</strong> cold<br />
lead segment<br />
PyroFLX<br />
PyroFLX<br />
transition<br />
<strong>MI</strong> <strong>Heating</strong> <strong>Cable</strong> — Alloy 825 with PyroFLX Cold Lead<br />
PyroFLX (End A)<br />
Heated<br />
length<br />
PyroFLX (End B)<br />
Heated<br />
PyroFLX (End A) length<br />
PyroFLX (End B)<br />
<strong>Heating</strong> <strong>Cable</strong> Catalog Number To order an <strong>MI</strong> heating cable with the PyroFLX cold lead option, it is important to understand the<br />
format of our catalog number.<br />
E/32SP4583/40/1800/68.1/5-7/LS23A/X/T8-10/RLFM<br />
Design E<br />
Flexible polymeric<br />
tray cable<br />
Quick connector<br />
(also available<br />
without connector)<br />
End B; F = Female connector; M = Male connector<br />
(use only with Design B and Design E cables)<br />
End A; F = Female connector; M = Male connector<br />
L = Molded connector; K = Field-attachable connector<br />
PyroFLX cold lead<br />
Length of tray cable; End A - End B (feet)<br />
Hot/cold joint type, “X” (stainless steel) is standard for Alloy 825 cables<br />
Standard <strong>MI</strong> cold lead code(see Table 1)<br />
Length of standard <strong>MI</strong> cold lead; End A - End B (feet)<br />
<strong>Heating</strong> cable voltage<br />
<strong>Heating</strong> cable wattage<br />
<strong>Heating</strong> cable length (in feet)<br />
<strong>Heating</strong> cable reference (see Tables 3, 4, 5 in<br />
H56870, <strong>MI</strong> <strong>Heating</strong> <strong>Cable</strong> - Alloy 825 data sheet)<br />
<strong>Heating</strong> cable design configuration (A, B, D, E)<br />
In the above heating cable catalog number, the length of the heated section, standard <strong>MI</strong> cold<br />
lead and the PyroFLX cold lead are in feet. For metric lengths, the heating cable catalog number<br />
would include a suffix “M” after the length, as follows: E/32SP4583/12.2M/1800/68.1/1.5-<br />
2.1M/LS23A/X/T2.4-3.0M/RLFM<br />
Conversion from English to Metric units is: L(ft) x 0.3048 = L(m)<br />
Conversion from Metric to English units is: L(m) x 3.2808 = L(ft)<br />
For Hazardous areas, specify approval required (see above Approvals section).<br />
H58737 2/11 www.tycothermal.com 3 of 4<br />
1. Self-<br />
Regulating<br />
<strong>Cable</strong>s<br />
2. Power-<br />
Limiting<br />
<strong>Cable</strong>s<br />
3. Mineral<br />
Insulated<br />
<strong>Cable</strong>s<br />
4. Longline<br />
<strong>Heating</strong><br />
5. Tubing<br />
Bundles<br />
6. Tank<br />
<strong>Heating</strong><br />
7. Snow and<br />
Ice<br />
8. Control and<br />
Monitoring<br />
9. Heat-Trace<br />
Panels<br />
10.Engineered<br />
Products<br />
11.Steam-<br />
Tracing<br />
Systems<br />
12.Technical<br />
Data<br />
Sheets<br />
13.Appendixes 14.Index