OCTG Division – R&D Premium Connections<strong>VAM</strong> <strong>Technical</strong> <strong>Notes</strong><strong>Compatibility</strong> <strong>between</strong> <strong>VAM</strong> connections


<strong>VAM</strong> connections cannot be run with anyother <strong>VAM</strong> connections, except NEW <strong>VAM</strong>with Old <strong>VAM</strong> connections (<strong>VAM</strong> Std, <strong>VAM</strong> AF,<strong>VAM</strong> AG and <strong>VAM</strong> ATAC) and Casing <strong>VAM</strong>TOP family connections (<strong>VAM</strong> TOP, <strong>VAM</strong> TOPHT, <strong>VAM</strong> TOP HC and <strong>VAM</strong> TOP FE).When these products are Isolated andnamed "Nx" they are not compatible with anyproducts.For <strong>VAM</strong> TOP Tubing, <strong>VAM</strong> FJL, <strong>VAM</strong>SLIJ-II, <strong>VAM</strong> SFC, <strong>VAM</strong> HW ST and <strong>VAM</strong> SL,pipes with the same diameter may havedifferent threads tapers or threaded lengthsdepending on their wall thickness and are notcompatible.Mixing of <strong>VAM</strong> connections is notrecommended, but sometimes it's possible tomake-up some connections together withprecautions described below. The usage of across over is strongly recommended whenpossible and in all case where connections arenot compatible.OD B(mm) B(mm)NEW <strong>VAM</strong> <strong>VAM</strong> Std5" 116.0 118.05 ½" 119.5 120.06 5/8" 122.0 125.07" 129.0 130.07 5/8" 133.5 135.08 5/8" 135.0 138.09 5/8" 135.0 138.010 ¾" 136.0 138.011 ¾" 136.0 138.013 3/8" 137.5 138.0<strong>Compatibility</strong> <strong>between</strong> <strong>VAM</strong> andButtress connectionRecommendationsThe assembly of <strong>VAM</strong> or NEW <strong>VAM</strong>connections with BUTTRESS connections isnot recommended since the thread profile of<strong>VAM</strong>/NEW <strong>VAM</strong> has more clearance than aBUTTRESS. However if no choice is left, andif the connection is located at a non strategicplace (below the packer for example), end usercan use the following method at their own risk.It's also to the end user to decide to"bakerlock" the connection.This kind of assemblies has got nosealing properties.Make up of <strong>VAM</strong>/NEW <strong>VAM</strong> Pin withBUTTRESS box enda) stamp a triangle at a distance (B) from endof <strong>VAM</strong> or NEW <strong>VAM</strong> pin end. Height oftriangle = 9.5mmb) make up tolerance :mini = the face of coupling at the base oftriangleMaxi = the face of coupling at 3mm over thebaseNote : it is strongly recommended to cut thenose of <strong>VAM</strong> or NEW <strong>VAM</strong> after stamping thetriangle.When making up of 2 <strong>VAM</strong> pin ends intothe Buttress box, it is absolutely necessary tocut minimum one pin nose.Make up of BUTTRESS Pin with <strong>VAM</strong>or NEW <strong>VAM</strong> box endCaution : it is normally absolutely forbidden tomake-up a BUTTRESS pin end with a <strong>VAM</strong> orNEW <strong>VAM</strong> box end. But, if a customer has gotno choice, he can decide at his own risk to usethe following method.a) Ensure that pin end root threads arevanishing on OD pipe.b) For make-up on <strong>VAM</strong> or NEW <strong>VAM</strong>, grindout the Buttress triangle and draw a line atthe (B) value.Compatibilty <strong>between</strong> <strong>VAM</strong> connections Page 2 / 4


OD B(mm) B(mm)NEW <strong>VAM</strong> <strong>VAM</strong> Std5" 108.5 96.05 ½" 112.0 98.06 5/8" 114.5 103.07" 121.5 108.07 5/8" 126.0 113.08 5/8" 129.5 116.09 5/8" 129.5 116.010 ¾" 130.0 116.011 ¾" 130.0 116.013 3/8" 129.0 116.0c) make up tolerance :mini = the face of coupling at 1mm beforethe lineMaxi = the face of coupling at the lineNote : in this case, we strongly recommend to"bakerlock" the connection.<strong>Compatibility</strong> <strong>between</strong> <strong>VAM</strong> andNEW <strong>VAM</strong> connections<strong>Compatibility</strong> <strong>between</strong> <strong>VAM</strong> and NEW<strong>VAM</strong> connectionNEW <strong>VAM</strong>, <strong>VAM</strong>, <strong>VAM</strong> AF <strong>VAM</strong> AG and<strong>VAM</strong> ATAC can be combined but the torque tobe applied depends only on the box memberdesign.BoxPinNEW <strong>VAM</strong>NEW <strong>VAM</strong> MS (1)<strong>VAM</strong><strong>VAM</strong> ATAC<strong>VAM</strong> AG<strong>VAM</strong> AFNEW <strong>VAM</strong> SC<strong>VAM</strong> SC (2)NEW <strong>VAM</strong>NEW <strong>VAM</strong> MS (1)NEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum Torque<strong>VAM</strong><strong>VAM</strong> ATACNEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum Torque<strong>VAM</strong> AG<strong>VAM</strong> AFNEW <strong>VAM</strong>Minimum TorqueNEW <strong>VAM</strong>Minimum TorqueNEW <strong>VAM</strong>Minimum TorqueNEW <strong>VAM</strong>Minimum Torque(1) M.S matched Strength – (2) SC Special CouplingNEW <strong>VAM</strong> SC<strong>VAM</strong> SC (2)NEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum TorqueNEW <strong>VAM</strong>Optimum TorqueNote : only applicable for sizes from 2 3/8" upto 9 5/8". For bigger diameter see below<strong>Compatibility</strong> <strong>between</strong> <strong>VAM</strong> / NEW<strong>VAM</strong> Draft and NEW <strong>VAM</strong> 4000connectionsFor 10 ¾", 11 ¾" and 13 3/8" NEW <strong>VAM</strong>connections different drafts have beendesigned (and produced) and are replaced bythe final drawings called NEW <strong>VAM</strong> 4103,4113 and 4133. These drawings, reflecting theimprovement of the properties of theconnections.10 ¾" CONNECTIONSBox endPin end<strong>VAM</strong> standardSTD 390 rev I01/10/1982NEW <strong>VAM</strong> DraftSTD 150808/04/1987NEW <strong>VAM</strong> DraftSTD 150811/03/1988NEW <strong>VAM</strong> DraftSTD 4103 rev A08/02/1990<strong>VAM</strong> stdSTD 390 rev I01/10/1982FullycompatiblePossiblemake-up (*)Possiblemake-up (*)Possiblemake-up (*)11 ¾" CONNECTIONSBox endPin end<strong>VAM</strong> stdSTD 511 rev B01/10/1982NEW <strong>VAM</strong> DraftSTD 150911/03/1988NEW <strong>VAM</strong>STD 4113 rev A08/02/1990<strong>VAM</strong> stdSTD 511 rev B01/10/1982FullycompatiblePossible makeup(*)Possible makeup(*)13 3/8" CONNECTIONSPin endBox end<strong>VAM</strong> standardSTD 373 rev M21/09/1984NEW <strong>VAM</strong> DraftSTD 151008/04/1987NEW <strong>VAM</strong> DraftSTD 151011/03/1988NEW <strong>VAM</strong>STD 4133 rev A08/02/1990STD 4004 rev A21/09/1989 ELF UK<strong>VAM</strong> stdSTD 373 rev M21/09/1984FullycompatiblePossible makeup(*)Possible makeup(*)Possible makeup(*)NEW <strong>VAM</strong>Draft STD150808/04/1987Possiblemake-up (*)FullycompatibleFullycompatibleFullycompatibleNEW <strong>VAM</strong>Draft STD151008/04/1987Possiblemake-up (*)FullycompatibleFullycompatiblePossiblemake-up (*)NEW <strong>VAM</strong>Draft STD150811/03/1988Possiblemake-up (*)FullycompatibleFullycompatibleFullycompatibleNEW <strong>VAM</strong> DraftSTD 150911/03/1988Possiblemake-up (*)Fully compatibleFully compatibleNEW <strong>VAM</strong>Draft STD151011/03/1988Possiblemake-up (*)FullycompatibleFullycompatiblePossiblemake-up (*)NEW <strong>VAM</strong>STD 4103 revA 08/02/1990Possiblemake-up (*)FullycompatibleFullycompatibleFullycompatibleNEW <strong>VAM</strong>STD 4113 revA 08/02/1990Possiblemake-up (*)FullycompatibleFullycompatibleNEW <strong>VAM</strong>STD 4133 rev A08/02/1990STD 4004 rev A21/09/1989 ELF UKNot compatibleNot compatibleNot compatibleFully compatibleNote * : Connection noted as "Possible makeup"may not guarantee the equivalentproperties as the ones achieved with the <strong>VAM</strong>Standard connection.Not compatible : No make-up is possible<strong>between</strong> these 2 products.Compatibilty <strong>between</strong> <strong>VAM</strong> connections Page 3 / 4


<strong>VAM</strong> TOP connectionsCasing <strong>VAM</strong> TOP, <strong>VAM</strong> TOP HT and<strong>VAM</strong> TOP HC threads are interchangeable(seal taper = 20°). Nevertheless due to the gap<strong>between</strong> D1 / D2 values of <strong>VAM</strong> TOP HT /<strong>VAM</strong> TOP HC connections with <strong>VAM</strong> TOP theusage of a cross-over is mandatory. <strong>VAM</strong> TOP casing is compatible with<strong>VAM</strong> TOP HT / <strong>VAM</strong> TOP HCParticular case of 4 ½"Same Thread Profile for <strong>VAM</strong> TOPcasing, <strong>VAM</strong> TOP HT, <strong>VAM</strong> TOP HC but <strong>VAM</strong>TOP tubing has is own Thread ProfileSame Seal Profile for <strong>VAM</strong> TOP HT and<strong>VAM</strong> TOP HC (20° seal angle) but <strong>VAM</strong> TOPtubing has is own Seal Profile (50% sealtaper).Torque value is different for eachconnection 4 ½” <strong>VAM</strong> TOP HC / HT is NOT compatiblewith 4 ½” <strong>VAM</strong> TOP tubing. 4 ½” <strong>VAM</strong> TOP HC does not offercompression advantage on 4 ½” <strong>VAM</strong> TOP“standard” and does not exist any more<strong>VAM</strong> TOP FECases exist, where there is a need toassemble <strong>VAM</strong> TOP and <strong>VAM</strong> TOP FEthreads, for example hydraulic test plugs orpossibly accessories. This kind of assembly isto be considered very cautiously since theresulting fatigue performance can no longer beguaranteed : it is therefore not a recommendedpractice.Due to the specificity of <strong>VAM</strong> TOP FEthread profile compared to <strong>VAM</strong> TOP, <strong>VAM</strong>TOP pin ends can be assembled with <strong>VAM</strong>TOP FE couplings, but <strong>VAM</strong> TOP FE pin endscan not be made up with <strong>VAM</strong> TOP box ends.See following compatibility chart.<strong>VAM</strong> TOPPin<strong>VAM</strong> TOP FEPin<strong>VAM</strong> TOP FEBoxCompatible<strong>VAM</strong> TOPNot compatibleBox<strong>Compatibility</strong> chart <strong>between</strong> <strong>VAM</strong> TOP & <strong>VAM</strong> TOP FE connectionsCompatibilty <strong>between</strong> <strong>VAM</strong> connections Page 4 / 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!