Bobcat Boiler Display Board - Slant/Fin
Bobcat Boiler Display Board - Slant/Fin
Bobcat Boiler Display Board - Slant/Fin
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
9<br />
Table 1<br />
Note:<br />
Mode<br />
<strong>Display</strong><br />
<strong>Bobcat</strong> <strong>Boiler</strong> <strong>Display</strong> <strong>Board</strong><br />
“<strong>Boiler</strong> Operation Status”<br />
<strong>Bobcat</strong> Model B-120 and B-200<br />
Description & Temperature <strong>Display</strong><br />
<strong>Boiler</strong> is on stand-by mode.<br />
Temperature display shows supply water Temp.<br />
Space heating mode.<br />
Temperature display shows supply water Temp.<br />
Domestic hot water mode.<br />
Temperature display shows supply waterTemp.<br />
Frost protection mode.**<br />
Temperature display shows supply water Temp.<br />
Lockout (Alarm) condition.<br />
Temperature <strong>Display</strong> indicates the lockout code<br />
Reset button must be pressed to resume normal operation.<br />
Error Condition. *<br />
Temperature display indicates the error code.<br />
Warning Condition. ***<br />
Temperature display indicates the error code.<br />
Blinking dot on “Mode <strong>Display</strong>” indicates active heating control, burner off. Steady dot<br />
indicates burner is on.<br />
*: Error must be corrected to resume boiler operation. Pressing the “Reset” button is not<br />
required.<br />
**: The boiler circulator is energized, when boiler water temperature drops below 50°F.<br />
***: Error must be corrected to resume DHW operation. Space heating not affected.<br />
Pressing the “Reset” button is not required.