PAGE951. Overaeration in the aeration basin will cause which <strong>of</strong> thefollowing to occur in the secondary sedimentation basin?A.B.Improved settling <strong>of</strong> the activated sludge.Increased oxygen uptake by the sludge.C. Sludge bulking.D. Small floc particles floating on tank surface.52. The proper way to start up an anaerobic digester is t<strong>of</strong>ill itA. Halfway with seed sludge, then add raw sludge slowly.B. Up first with raw sludge and wastewater.C. Up with waste activated sludge.D. With seed sludge, add lime to pH 10 and mix.53. In a low pressure wet oxidation unit's steam generator, the waterbeing converted into steam should have a hardness <strong>of</strong>grains per gallon.A. O.B. 2.C. 5.D. 7.54. You have observed water spraying out <strong>of</strong> the vacuum filter'ssilencer (or snubber) exhaust pipe. which <strong>of</strong> the followingconditions is the most likely cause <strong>of</strong> the problem?A.B.Fil~rate pump nor-functioning properly.Vacuum too high.C. Vacuum too low..D. Worn check valves in vacuum system.55. Analysis <strong>of</strong> a wastewater effluent from a standard ratetrickling filter shows the following:Nitrite = 8 mg/L.Ammonia = 2 mg/L.Nitrate = 2 mg/L.What do these results indicate?A. Plant is operating properly.B. Final end product, nitrite, is too low.C. Final end product, nitrate, is too low.D. DO was insufficient to allow complete aerobic oxidation<strong>of</strong> the nitrate to nitrite.56. In the final clarifier <strong>of</strong> an activated sludge plant, theoperator noted the following conditions. At times, small,almost transparent, very light fluffy, buoyant sludgeparticles (one-eighth to one-quarter inch in diameter) wererising to the clarifier surface near the outlet weirs. Itappeared to be more pronounced at high return sludge flowrates. The final effluent was otherwise exceptionally clear,even though the condition occurred during relatively lowsurface overflow rates. Mixed liquor concentration wasrelatively low at this time. This situation is calledA.B.Ashing.Bulking.C. Pin floc.D. Stragg ler floc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!