12.07.2015 Views

TAC XentaTM 913 - Xref

TAC XentaTM 913 - Xref

TAC XentaTM 913 - Xref

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>TAC</strong> <strong>XentaTM</strong> <strong>913</strong><strong>TAC</strong> Xenta TM <strong>913</strong> is a cost effective gateway for integrating a large variety of productsinto a <strong>TAC</strong> network. It lets you build a seamless integrated system with a single operatorinterface with full functionality at the network level. The <strong>TAC</strong> Xenta <strong>913</strong> supports themost commonly used open protocols, like LonWorks ® and BACnet, etc. The <strong>TAC</strong> Xenta<strong>913</strong> transfers values between supported networks.• Bridges the gap between protocols• The key to seamless integration ofdifferent vendors systems• Direct communication with third partyproducts at the field level• Migration and update of systems withoutreplacement of older equipmentTHE <strong>TAC</strong> Xenta <strong>913</strong> SOLUTIONThe <strong>TAC</strong> Xenta <strong>913</strong> provides a fast, reliable method of protocol conversion from oneformat to another. The <strong>TAC</strong> Xenta <strong>913</strong> bridges the gap between protocols, allowinglegacy hardware to coexist with open systems such as <strong>TAC</strong> Vista. It gives you thefreedom to migrate to open systems and to upgrade your site without having to replaceolder equipment.MANY OPTIONS<strong>TAC</strong> offers a wide variety of protocol options. These protocols enable multiple vendorsystems such as chillers, lifts, fire alarms and energy meters all to be connected to onefront end Building Management System. The <strong>TAC</strong> Xenta <strong>913</strong> supports many commonprotocols like TCP/IP, LonTalk ® , Modbus, BACnet TM and other legacy systems.For more than a decade, <strong>TAC</strong> has been providing hundreds of gateway solutions forinstallations all over the world. Some of the systems that can be interfaced include:• Chillers• Fire Panels• Boilers• Generators• Uninteruptable Power Supply (UPS)• Power Meters• Programmable Logic Controllers• Lighting Systems• Air-conditioning System• ElevatorsONE SYSTEM – MANY FUNCTIONSUsing <strong>TAC</strong> Xenta <strong>913</strong> you will be able to monitor and control your entire facility withone operator interface like <strong>TAC</strong> Vista TM .There is no need to have multiple PCs and software's and no need to learn differentuser interfaces and applications. The operators can concentrate on one set of graphicsand one alarm system. You need not to replace existing equipment to achieve this. Youcan continue to expand your facility according to your budgets and get the maximumvalue from your installed equipment.


RELIABLE AND COST EFFECTIVE<strong>TAC</strong> Xenta <strong>913</strong> communicates with thirdparty products, at the Field level, thereforeno computer or PC is involved in thedata exchange. No hard disks to fail, nounreliable operating systems that crashfrequently and no one canaccidentally turn it off.PC based interfaces are more expensiveto implement as you have to purchasethe PC, generally an expensive industrialgrade unit, an operating system and anUPS to maintain power. This is beforeyou have even purchased the softwarethat will do the protocol translation. Withthe data exchange occurring at a locallevel, the speed and reliability of dataexchange to the third-party system is significantlyimproved with <strong>TAC</strong> Xenta <strong>913</strong>compared to other companies PC basedsolutions. This can be vital when the integrationis to a critical system like a firepanel or an emergency power system.EASY TO USE<strong>TAC</strong> is committed to provide gatewaysthat are easy to install, configure and operate.We provide a full suite of supporttools to simplify the configuration of thegateway. These tools are customized tosuit each type of protocol with a familiarWindows look.The <strong>TAC</strong> Xenta <strong>913</strong> diagnostic tools aredesigned to help you deal successfullywith many of the common problemsthat rise when you integrate to third partsystems. The <strong>TAC</strong> Xenta <strong>913</strong> can simultaneouslyact as a diagnostic interface andcommunication logger, remote accessiblevia an TCP/IP connection.SUGGESTED FIELD OFAPPLICATIONS• Link chiller plant into your BMS toprovide advanced load control andsequencing. Also provide continuousmonitoring of performance andremote annunciation of alarms throughthe BMS.• Integrate “smart” power meters intothe BMS to get sophisticated energymonitoring and reporting at your desktop.• Implement advanced load sheddingstrategies in both normal operationsand during power outages by integratingmechanical plant with dieselgenerators and UPS banks.• Link elevators, lighting, HVAC andaccess control to provide sophisticatedafter hour’s operation of the buildingsimply by swiping youraccess card in the elevator cab.• Avoid duplication of sensors on centralplant equipment like chillers and boilers.One set of sensors to calibrate andmaintain that reduces overall installationand maintenance costs.• Provide sophisticated fault changeoverand remote alarming systems for criticaloperations in telecommunicationand pharmaceutical industry as well asin hospitals.FEATURES• Secure interface for configuration withusername and password logon.• 16 Mbytes on board memoryexpandable to 128 Mbytes.• Powerful industrial grade microprocessorand real-time operating system.• Easy to use Windows configurationtools customized to each protocol.• Built-in support for diagnostic andcommunication logging operations.• Web interface for diagnostics.• Configuration is done with the easy touse <strong>TAC</strong> XBuilder software• Configurable via an RS-232 serial or anEthernet connection.SUPPORTED PROTOCOLS• LonWorks (FT-10)• BACnet (IP/PTP/MS-TP)• Modbus (Master/Slave/TCP)• I/NET (HLAN/CLAN)• M-bus (Meter bus)• C-bus (Clipsal bus)• LACnetCOMMUNICATIONS• Ethernet 10baseT with TCP/IPsupport.• LonWorks FTT-10A.• One EIA-232 serial port.• One configurable EIA-232 orEIA-485 port.Copyright © 2005, <strong>TAC</strong>All brand names, trademarks and registered trademarks arethe property of their respective owners. Information containedwithin this document is subject to change without notice.All rights reserved.SDS-XENTA<strong>913</strong>-US11/05www.tac.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!