Reference: TOS-MT/2002-18/JJ/nr Page 1 of 3 Status: 19 April 2002<br />
TYPE OF TEST<br />
Vibration<br />
Physical<br />
Measurements<br />
Acoustic<br />
Mechanical <strong>Test</strong><br />
Deployment<br />
MACHINE SPECIFIC<br />
Electrodynamic shaker<br />
Electrodynamic shaker<br />
Electrodynamic shaker<br />
Hydraulic shaker<br />
Electrodynamic shaker<br />
Electrodynamic shaker<br />
Centre of Gravity<br />
Moment of Inertia<br />
Dynamic Balance<br />
Spin<br />
Reverberant chamber<br />
Reverberant chamber<br />
Reverberant chamber<br />
LSS<br />
Table 1 – MECHANICAL TEST FACILITIES<br />
<strong>Coordinated</strong> <strong>European</strong> <strong>Environmental</strong> <strong>Test</strong> <strong>Facilities</strong> (CETeF)<br />
Shaker Force<br />
320 kN<br />
160 kN<br />
80 kN<br />
lateral : 940 kN<br />
vertical: 1880 kN<br />
320 kN<br />
320 kN<br />
Amplifier<br />
GENERAL CHARACTERISTICS<br />
384 kVA<br />
192 kVA<br />
192 kVA<br />
1000 kVA<br />
384 kVA<br />
256 kVA<br />
Control Modes<br />
sinus / random / transient<br />
sinus / random / transient<br />
sinus / random / transient<br />
sinus / transient / 6 DoF<br />
sinus / random / transient<br />
sinus / random / transient<br />
Admissible load<br />
3 facilities mass from 2 kg to 6000 kg<br />
1 facility mass up to 5000 kg<br />
3 facilities mass from 0.7 kg to 6000 kg<br />
3 facilities mass from 0.5 kg to 6000 kg *<br />
1 facility mass up to 5000 kg<br />
2 facilities mass from 0.05 kg to 6000 kg<br />
Volume<br />
1600 m 3<br />
1378m 3<br />
1100 m 3<br />
Up-to-date information and full details available in <strong>Test</strong>ing Division / ESTEC<br />
mass up to 5000 kg *<br />
mass up to 5000 kg *<br />
mass up to 2800 kg<br />
Sliptable<br />
yes<br />
yes<br />
yes<br />
N.A.<br />
yes<br />
yes<br />
Data Handling<br />
252 channels<br />
252 channels<br />
252 channels<br />
252 channels<br />
360 channels<br />
400 channels<br />
mass up to 5000 kg * * The largest of these<br />
mass up to 5000 kg facilities can be used<br />
mass up to 750 kg under vacuum.<br />
Noise Level<br />
Data Handling<br />
155 dB<br />
156 dB<br />
156 dB<br />
Volume ø 9.5 m. Height 10 m. Deployment up to 15 m in horizontal plane.<br />
Mechanical tests can be done under vacuum.<br />
252 channels<br />
256 channels<br />
400 channels<br />
LOCATION<br />
ESTEC<br />
ESTEC<br />
ESTEC<br />
ESTEC<br />
IABG<br />
ITS<br />
ESTEC<br />
ITS<br />
IABG<br />
ESTEC<br />
ITS<br />
IABG<br />
ESTEC<br />
ITS<br />
IABG<br />
ESTEC<br />
ITS<br />
IABG<br />
ESTEC<br />
IABG<br />
ITS<br />
ESTEC
Reference: TOS-MT/2002-18/JJ/nr Page 2 of 3 Status: 19 April 2002<br />
TYPE OF TEST<br />
Solar Simulation<br />
Thermal<br />
Vacuum<br />
Special<br />
Application<br />
<strong>Test</strong>s under<br />
Vacuum<br />
MACHINE SPECIFIC<br />
LSS<br />
SIMLES<br />
WSA/TVA<br />
LSS<br />
HBF3<br />
VTC 1.5<br />
CORONA<br />
WSA/TVA<br />
SIMLES<br />
SIMMER<br />
LSS<br />
LSS + Levelling Device<br />
Table 2 – THERMAL TEST FACILITIES<br />
<strong>Coordinated</strong> <strong>European</strong> <strong>Environmental</strong> <strong>Test</strong> <strong>Facilities</strong> (CETeF)<br />
Internal Dimensions<br />
ø 9.5m x 10 m high<br />
ø 6 m x 7 m high<br />
ø 6.2m x 12 m long<br />
Internal Dimensions<br />
ø 9.5m x 10 m high<br />
ø 3 m x 4 m high<br />
ø 1.5m x 2.5m high<br />
ø 1.5m x 3.5m long<br />
ø 6.2m x 12 m long<br />
ø 6 m x 7 m high<br />
ø 10 m x 8.3m long<br />
ø 9.5m x 10 m high<br />
Vacuum /<br />
mbar<br />
5.10E-7<br />
5.10E-7<br />
1.10E-6<br />
Fast Thermal<br />
Cycling<br />
LSS, HBF3, CORONA<br />
ATC 2<br />
0.06 m 3<br />
Up-to-date information and full details available in <strong>Test</strong>ing Division / ESTEC<br />
GENERAL CHARACTERISTICS<br />
Temp.<br />
LN2<br />
LN2<br />
LN2<br />
Sun Simulator<br />
ø 6 m parallel<br />
ø 3.8m parallel<br />
ø 3.6m parallel<br />
or 4.5m x 3.05m<br />
Vacuum / mbar<br />
≤ 5.10E-6<br />
5.10E-6<br />
5.10E-6<br />
5.10E-6<br />
≤ 1.10E-6<br />
5.10E-7<br />
5.10E-7<br />
down to 5.10E-6<br />
ambient pressure<br />
Spin Attitude<br />
Control<br />
5000 kg<br />
2500 kg<br />
2500 kg<br />
Temperature<br />
Data<br />
Handling<br />
Temperature<br />
1000 channels<br />
632 channels<br />
1000 channels<br />
150 K to 350 K<br />
200 K to 373 K<br />
123 K to 423 K<br />
193 K to 353 K<br />
100 K to 383 K<br />
100 K to 400 K<br />
100 K to 373 K<br />
Comments<br />
Physical measurements /<br />
deployment / mechanical tests.<br />
Vertical configuration<br />
Thermal cycling with IR rigs.<br />
rapid cycling up to 300 K/min<br />
93 K to 403 K<br />
LOCATION<br />
ESTEC<br />
ITS<br />
IABG<br />
ESTEC<br />
ESTEC<br />
ESTEC<br />
ESTEC<br />
IABG<br />
ITS<br />
ITS<br />
ESTEC<br />
ESTEC<br />
ESTEC<br />
ESTEC
Reference: TOS-MT/2002-18/JJ/nr Page 3 of 3 Status: 19 April 2002<br />
Table 3 - OTHER FACILITIES<br />
<strong>Coordinated</strong> <strong>European</strong> <strong>Environmental</strong> <strong>Test</strong> <strong>Facilities</strong> (CETeF)<br />
TYPE OF TEST<br />
Magnetic<br />
Optical<br />
Measurements<br />
and Calibration<br />
under Thermal<br />
Vacuum<br />
EMC<br />
Clean Room<br />
Alignment<br />
MACHINE SPECIFIC<br />
3 axis<br />
15 m square coils<br />
4 coils per axis<br />
Focal 1.5<br />
Focal 2<br />
Focal 5 (class 100)<br />
EMC (CPTR)<br />
EMC<br />
EMC<br />
EMC<br />
Building Fh<br />
Building Fj<br />
Building Fl (HYDRA)<br />
Building Fr<br />
Integration cabin<br />
Pascal<br />
EMC hall<br />
MVS hall<br />
Preparation hall A + B<br />
Thermal test area<br />
Mechanical test area<br />
Integration area<br />
Preparation area/acoustic fac<br />
Integration hall<br />
Integration hall<br />
Precision<br />
Alignment<br />
Equipment<br />
Up-to-date information and full details available in <strong>Test</strong>ing Division / ESTEC<br />
GENERAL CHARACTERISTICS<br />
Zero field / DC fields: sphere ø 4 m for 0 to 75,000 nT;<br />
field vector in any direction; rotating fields; uniformity 5 nT in ø 4 m<br />
AC fields: sphere ø 4 m for 0 to 10,000 nT.Hz; resolution 0.1 nT.Hz<br />
Demagnetisation: 0 to 5 mT, 0 to 0.3 Hz; 1T = 10E4 Gauss = 10E9 gamma = 10E9 nT<br />
Internal volume ø 1.2 m x 0.8 m Vacuum 1.10E-6 mbar Temp. 90 K / 523 K<br />
Internal volume ø 1.8 m x 5 m Vacuum 1.10E-6 mbar Temp. 90 K / 373 K<br />
Optical bench 1.3 m x 4.7 m inside the chamber (on 450 t seismic block)<br />
Internal volume ø 5 m x 6 m vacuum 1.10E-7 mbar Temp. 4 K / 373 K<br />
Optical bench 1.8 m x 6 m inside the chamber (on 450 t seismic block) 500 channels<br />
Internal volume 25.6 m x 15.5 m x 10.5 m high frequency up to 40 Ghz<br />
7.1 m x 6.1 m x 5 m high frequency up to 40 Ghz<br />
16 m x 10 m x 11 m high frequency up to 40 Ghz<br />
10.5 m x 7 m x 8 m high frequency up to 40 Ghz<br />
Total area = 250 m 2 Class 10,000 Temp. 20°C ± 1°C ; HR = 55%<br />
Total area = 280 m 2 Class 100,000 Temp. 20°C ± 1°C ; HR = 55%<br />
Total area = 700 m 2 Class 100,000 Temp. 20°C ± 1°C ; HR = 55%<br />
Total area = 600 m 2 Class 100,000 Temp. 20°C ± 1°C ; HR = 55%<br />
Total volume = 400 m 3 Class 100 Temp. 20°C ± 1°C ; HR = 55%<br />
Total area = 2 x 280 m 2 Class 100,000 Temp. 20°C ± 2°C ; HR = 55%<br />
High bay = 145 m 2 Class 100,000<br />
Total area = 190 m 2 Class 100,000 Temp. 20°C ± 1°C ; HR = 55%<br />
Total area = 570 m 2 Class 100,000 / 100 Temp. 21°C ± 2°C ; HR = 50%<br />
Total area = 490 m 2 Class 100,000 / 10,000 Temp. 21°C ± 2°C ; HR = 50%<br />
Total area = 200 m 2 Class 100,000 Temp. 21°C ± 2°C ; HR = 50%<br />
Total area = 480 m 2 Class 100,000 Temp. 21°C ± 2°C ; HR = 50%<br />
Total area = 125 m 2 Class 100,000 Temp. 21°C ± 2°C ; HR = 50%<br />
Total area = 465 m 2 Class 10,000 Temp. 20°C ± 1°C ; HR = 55%<br />
Total volume = 130 m 3 Class 100 Temp. 20°C ± 1°C ; HR = 55%<br />
Optical non-contact 3-D alignment system (MANCAT).<br />
Two theodolites with interface to a PC with dedicated software.<br />
Digital high precision autocollimation theodolites including stands and software.<br />
Rotary tables including optical reference systems and level stands.<br />
Micro-alignment telescopes and autocollimators.<br />
LOCATION<br />
IABG<br />
CSL<br />
CSL<br />
CSL<br />
ESTEC<br />
ESTEC<br />
ITS<br />
IABG<br />
ESTEC<br />
ESTEC<br />
ESTEC<br />
ESTEC<br />
ESTEC<br />
ITS<br />
ITS<br />
ITS<br />
IABG<br />
IABG<br />
IABG<br />
IABG<br />
IABG<br />
CSL<br />
CSL<br />
ESTEC