<strong>Elram</strong> <strong>Engineering</strong><br />

<strong>and</strong> <strong>advanced</strong> <strong>technologies</strong> <strong>1992</strong> <strong>Ltd</strong>.<br />

Drive units for Poultry Houses<br />

Special motor 0.25KW<br />

Special 24VDC<br />

elecromagnetic brake<br />

Shaft extension<br />

for manual operation<br />

Curtain Drop Motor<br />

New temporary version<br />

<strong>Elram</strong> <strong>Engineering</strong> & Advanced Technologies <strong>1992</strong> <strong>Ltd</strong>.<br />

3 4 G e s h e r H a e t s S t . , P. O. B o x 1 2 0 7 8 , I n d u s t r i a l P a r k<br />

E m e k H e f e r 3 8 7 7 7 , I s r a e l<br />

Tel: +972-4-6220766 (MULTI-LINE) Fax: +972-4-6220760<br />

Direct : +972-4-6220758 Mobile: +972-52-8995400<br />

elrameng @elrameng.com www.agri-motors.com<br />

Bevel helical gearbox<br />

- special execution<br />

Limit switch system<br />

Double extended<br />

output shaft<br />

Mechanical (passive) curtain drop motor.<br />

This motor is used as a motor for lifting<br />

curtain in poultry houses.<br />

In addition, it has the quality of self<br />

dropping the curtain in case of power<br />

failure.<br />

Note- for certain curtains, a counter<br />

balance weight must be added<br />

(consult us).<br />

The unit consists of :<br />

AC motor with built on special<br />

electromagnetic brake<br />

helical-bevel gearbox with special<br />

construction.<br />

Limit switch system<br />

��������<br />

������<br />

�� ����� ���� ���������� ������ ����� �����<br />

�� ����� ���� �� ���� ��������� ������ ����� �����<br />

�� ����� ������ ������������ �� ������ ���������<br />

CDM2008-P07-Rev.00 Graphic design: Michael Grosberg


<strong>Elram</strong> <strong>Engineering</strong><br />

<strong>and</strong> <strong>advanced</strong> <strong>technologies</strong> <strong>1992</strong> <strong>Ltd</strong>.<br />

Connection diagram for type HS56<br />

<strong>Elram</strong> <strong>Engineering</strong> & Advanced Technologies <strong>1992</strong> <strong>Ltd</strong>.<br />

3 4 G e s h e r H a e t s S t . , P. O. B o x 1 2 0 7 8 , I n d u s t r i a l P a r k<br />

E m e k H e f e r 3 8 7 7 7 , I s r a e l<br />

Tel: +972-4-6220766 (MULTI-LINE) Fax: +972-4-6220760<br />

Direct : +972-4-6220758 Mobile: +972-52-8995400<br />

elrameng @elrameng.com www.agri-motors.com<br />

CDM2008-P07-Rev.00 Graphic design: Michael Grosberg


<strong>Elram</strong> <strong>Engineering</strong><br />

<strong>and</strong> <strong>advanced</strong> <strong>technologies</strong> <strong>1992</strong> <strong>Ltd</strong>.<br />

Instruction manual - Passive mechanical curtain drop motor type BH56<br />

Danger: Take extreme care when operating the manual shaft.<br />

All electrical motor connections must be off <strong>and</strong> secured before <strong>and</strong> during use of the manual shaft.<br />

After operation remove all cranks of the back shaft, <strong>and</strong> put back the plastic cover.<br />

Do not attempt to operate the unit before you have read <strong>and</strong> understood the instructions.<br />

If you do not underst<strong>and</strong> any part of this document please contact <strong>Elram</strong> for explanations.<br />

<strong>Elram</strong>’s responsibility is limited to repairing or replacing faulty parts, subject to our st<strong>and</strong>ard sales<br />

conditions. No responsibility is taken for indirect or third party claim or damage.<br />

BH56 is a curtain motor with “drop” capability.<br />

The “drop” capability is limited to some conditions that must be specially considered for any curtain system.<br />

The unit is constructed of three main parts:<br />

A. Gearbox, special internal construction, having the ability to be driven from the output shaft under<br />

some torque conditions.<br />

B. Motor, special construction, 3 phase (or single phase), with backshaft extension for manual operation<br />

in case of power failure. Take extreme care for manual operation.<br />

C. Electromagnetic brake, 24VDC, special construction.<br />

When operating as a normal curtain operator, the brake is operated when motor power is off, thus securing<br />

the system in position.<br />

When power failure occurs, the brake is automatically released, causing the HB56 operator to be driven by<br />

the curtain (due to its weight), enabling “open” condition of curtain.<br />

Note: in some applications, the curtain is too short, or having too much friction, so the system does not have<br />

enough torque for safe “back rotation” of the gearbox through the output shaft.<br />

In such cases the system should use an “extra-weight” kit that enables the safe operation under all system’s<br />

conditions. The “extra weight” kit consists of drum+ cable (or strap) + weight.<br />

On the other h<strong>and</strong>, an excessive “extra weight” will cause extra loading of the motor <strong>and</strong> should be avoided.<br />

The system must be installed <strong>and</strong> tested for the “worst case”, taking into consideration that the curtain <strong>and</strong><br />

parts may wear out, <strong>and</strong> friction may increase with time.<br />

Note: increasing “extra-weight” too much will cause extra load (<strong>and</strong> higher current) during normal operation<br />

of motor; please take care to add weight only for the needed extreme case, but not more.<br />

The system must be checked by the user on a monthly basis, <strong>and</strong> results must be recorded on a<br />

maintenance log.<br />

The test will be:<br />

A. Cause “Power off” at the 2 motors on 2 sides of house.<br />

B. Observe that the 2 curtains are sliding down at similar speed until end of stroke, <strong>and</strong> no change has<br />

occurred from last month’s test.<br />

C. Record OK on log, with date <strong>and</strong> your signature.<br />

Not performing the above regular checks will automatically cancel any warrantee.<br />

The manufacturer warrantees the units only against failure in materials or workmenship, subject to sales<br />

conditions, but not against any indirect damage that may be caused to poultry in any circumstances.<br />

Please keep updated for last revision of these instructions.<br />

<strong>Elram</strong> <strong>Engineering</strong> & Advanced Technologies <strong>1992</strong> <strong>Ltd</strong>.<br />

3 4 G e s h e r H a e t s S t . , P. O. B o x 1 2 0 7 8 , I n d u s t r i a l P a r k<br />

E m e k H e f e r 3 8 7 7 7 , I s r a e l<br />

Tel: +972-4-6220766 (MULTI-LINE) Fax: +972-4-6220760<br />

Direct : +972-4-6220758 Mobile: +972-52-8995400<br />

elrameng @elrameng.com www.agri-motors.com<br />

CDM2008-P07-Rev.00 Graphic design: Michael Grosberg


<strong>Elram</strong> <strong>Engineering</strong><br />

<strong>and</strong> <strong>advanced</strong> <strong>technologies</strong> <strong>1992</strong> <strong>Ltd</strong>.<br />

Regular check report for BH56 – passive “curtain drop” system<br />

Due to the high sensitivity of the system, monthly checks are required in order to assure long range correct<br />

operation.<br />

Checks will be made every month, within the first week of the month.<br />

The user must write the date of the check <strong>and</strong> sign.<br />

Signed files should be kept by the user <strong>and</strong> copies are to be sent every year to the system’s supplier.<br />

Check steps:<br />

1. Cause “power off” for the 2 sides curtain motors.<br />

2. Observe the 2 curtains when dropping. It should be similar at both sides,<br />

<strong>and</strong> same as last month’s test.<br />

3. Please check the motor current at both sides. Record the max. current at operation.<br />

4. If you observe any problem or change in operation or measured current, please contact without<br />

delay your dealer or <strong>Elram</strong>.<br />

5. If you observe any oil leak or other problem, please contact your dealer immediately.<br />

S/N_________ Date of installation_________<br />

2010 -Month Date Name Max.Current at<br />

January<br />

February<br />

March<br />

April<br />

May<br />

June<br />

July<br />

August<br />

September<br />

October<br />

November<br />

December<br />

operation<br />

2010 -Month Date Name Max.Current at<br />

January<br />

February<br />

March<br />

April<br />

May<br />

June<br />

July<br />

August<br />

September<br />

October<br />

November<br />

December<br />

operation<br />

<strong>Elram</strong> <strong>Engineering</strong> & Advanced Technologies <strong>1992</strong> <strong>Ltd</strong>.<br />

3 4 G e s h e r H a e t s S t . , P. O. B o x 1 2 0 7 8 , I n d u s t r i a l P a r k<br />

E m e k H e f e r 3 8 7 7 7 , I s r a e l<br />

Tel: +972-4-6220766 (MULTI-LINE) Fax: +972-4-6220760<br />

Direct : +972-4-6220758 Mobile: +972-52-8995400<br />

elrameng @elrameng.com www.agri-motors.com<br />

OK -signature Notes<br />

OK -signature Notes<br />

CDM2008-P07-Rev.00 Graphic design: Michael Grosberg

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!