Product InformationPrimus 208The universal diaphragm dosing pumpPrimus 208 is truly silentWith a noise emission of 45 dB(A) Primus 208 is the most silent pump availablePrimus 208 is energy-savingDepending on the size, the power consumption is only 11 or 22 WPrimus 208 provides process safetySensors optionally integrated in the dosing head monitor the flow and the diaphragmPrimus 208 handles even problematic mediaDosing heads and valves in many different material combinations make Primus 208suitable for a wide range of industrial applications208/03.05EN


Primus 208Diaphragm dosing pumpMeasurements● Primus 208 with manual deaerationDrilling scheme Primus 208■ Primus 208 with automatic deaeration▲ Primus 208 InsideDrilling scheme Primus 208 InsideMeasurements in mmPump types● ■ ■ ▲ ● ■ ▲ ● ■ ▲ ● ■ ● ■A A1 A1* a B B1 b C C1 c D D1 E208-0.3 (IN) 225 - - - 13.7 - - 175.5 - - 112 - G 3/8“208-0.8 (IN) to -1.1 (IN) 225 - - 112 13.7 - 29 175.5 - 58 112 - G 3/8“208-1.6 (IN) to -3.0 (IN) 225 223 218 112 13.7 13.7 29 175.5 221.6 58 112 161 G 3/8“208-3.6 (IN) to -6.0 (IN) 225 223 218 112 13.7 13.7 29 175.5 221.6 58 112 161 G 3/8“208-9.0 (IN) to -18 (IN) 230 228.6 244 133 19.7 19.7 35 184.5 226.6 60 133 175 G 5/8“208/03.05ENPage 2www.alldos.com


Pump types• Mains voltage 230 V ± 10 %, 50/60 Hz, with cable and Euro plug• Without electronics, manual stroke adjustment, strokes per minute: 120 at 50 Hz, 144 at 60 Hz• Connections see page 4Primus 208Diaphragm dosing pump50 Hz 60 HzQ Pmax Q Pmax Q Pmax[l/h] [bar] [l/h] [bar] [USg/h] [psi]Vstroke[cm 3 ]Order number208 208 InsideMax. backpressure 10 bar, for 50 Hz0.3 10 0.36 10 0.095 145 0.04 208-0.31.0 10 1.2 10 0.317 145 0.14 208-1.0 208-1.0 IN1.6 10 1.92 10 0.507 145 0.22 208-1.6 208-1.6 IN2.9 10 3.5 7 0.925 102 0.42 208-3.0 208-3.0 IN4.0 8 4.8 6 1.27 87 0.55 208-4.0 208-4.0 IN5.0 6 6 5 1.58 72.5 0.69 208-5.0 208-5.0 IN6.0 8 7.2 6 1.902 87 0.84 208-6.0 208-6.0 IN9.0 6 11 5.5 2.853 80 1.24 208-9.0 208-9.0 IN14 4 16.8 3 4.439 44 1.92 208-14 208-14 IN18 3.5 21.6 3 5.702 44 2.46 208-18 208-18 INPrimus 208Max. backpressure 16 bar, for 50 Hz0.8 16 0.96 16 0.254 232 0.13 208-0.8 208-0.8 IN1.1 16 1.32 16 0.349 232 0.16 208-1.1 208-1.1 IN3.6 16 4.32 13 1.14 189 0.50 208-3.6 208-3.6 INMax. backpressure 20 bar, with automatic deaeration, for 50 Hz0.75 10 0.9 10 0.238 145 0.14 208-1.0 -1.2 10 1.44 10 0.380 145 0.22 208-1.6 -2.5 9 3,0 7 0.792 102 0.42 208-3.0 -3.5 8 4,2 6 1.109 87 0.55 208-4.0 -4.4 5 5.28 5 1.394 72,5 0.69 208-5.0 -5.47 8 6.5 6 1.711 87 0.84 208-6.0 -8.3 5 10 4 2.63 58 1.24 208-9.0 -13.3 3 16 3 4.213 44 1.92 208-14 -17 2.5 20.40 2 5.386 29 2.46 208-18 -Built-in pumpPrimus 208 Inside208-...INTechnical dataWith automaticdeaeration• especially suitable for strongly degassing and crystallizing fluidsfor example: hydrogen peroxide or peracetic acid• not suitable for chlorine bleaching!Accuracy dosing flow variation ± 1.5 %, linearity ± 4 %Noise emission± 45 dB(A), testing following DIN 45635-01-KL3Max. suction height6 m WC, for filled suction line and dosing head, continous operation Except 208-0.3: flooded suction!these details refer to non degassing media with viscosity similar to waterAdmission/backpressure max. 0.2 bar admission pressure at suction side / min. 1 bar backpressure at pressure sideMax. viscosity up to 200 mPa s (with automatic deaeraton up to 50 mPa s)Max. temperature max. ambient temperature 40 °CParts in contact with mediaPVC/Viton/glass, PVC/EPDM/ceramics, PP/Viton/glass, PVDF/PTFE/PTFEor stainless steel/PTFE/stainless steel; dosing diaphragm Viton /PTFE coatedMotorsynchronous motor with gear reduction 230 V or 115 V, 50/60 Hz11 W: for 208-0.3 / -1.0 / -1.6 / -3.0 / -4.0 22 W: for 208-0.8 / -1.1/ -3.6/ -5.0/ -6.0/ - 9.0/ -14/ -18Protection IP 65 degree of pump protection Except: Primus 208 Inside IP 20Weightapprox. 2.9 kg / RAL 6017; except Primus 208 Inside: approx. 1.5 kg208/03.05ENPage 3www.alldos.com


Primus 208Diaphragm dosing pumpOptionsMains voltage:• 220-240 V, 50/60 Hz• 110-120 V, 50/60 Hz• 24 V, 50/60 Hz, not for 208-18INMains plug / -cable• Euro / 1.5 m• Switzerland / 1.5 m• without mains plug / 1.5 mElectronics• Diaphragm breakage indication• Dosing controllerOptional electronics EtronContact signal and stroke frequency signal electronicsElectronics not available for Primus 208 Inside!Electronics without outputsEtron Input contacts N. O.Unidos Input contacts N. O.Electronics with outputsEtron, with multiplier /divisorUnidos, contact signal 1:1Outputs for error signal + pre-alert signal, contacts N. O.Outputs for error signal + stroke signal, contacts N. O.Outputs for error signal + pre-alert signal, contacts N. C.Outputs for error signal + stroke signal with <strong>Hall</strong> sensor, contacts N. O.Outputs for error signal + stroke signal, contacts N. O.Outputs for error signal + stroke signal with <strong>Hall</strong> sensor, contacts N. O.Signal transmissionDescriptionOrder numberCable with plug, length 2 mfor contact input, analog signal input and remote On/Off 321-205for outputs pre-alert / error signal and stroke signal 321-206Cable with plug, length 5 mfor contact input, analog signal input and remote On/Off 321-207for outputs pre-alert / error signal and stroke signal 321-208Combined plug / cable for diaphragm breakage indication and dosing controllercombined plug 5 poles 321-210cable 5 poles, length 5 m 321-223Accessories and armaturesFlow scheme of a complete dosing installation1 Dosing tank 5022 Electric agitator 5093 Pump Primus 2084 Suction line 531 with empty signal5 Overflow valve 5256 Pulsation damper 5177 Pressure retention valve 5258 Injection units 522208/03.05ENPage 5www.alldos.com


Primus 208Diaphragm dosing pumpSuction line systems• Flexible lines:PE plug ø 44 mm for tank, ceramic weight• Rigid lines for tanks:PE plug ø 44 mm for tank, protective PVC pipe,for ALLDOS tank 75 l (502-0075.1) without agitator• Rigid lines for containers:protective PVC pipe, container cover according to DIN 6131, for 5-12 l containers• Lines with empty signal / pre-alert for pumps with electronics:with foot valve, N.O. contactDescriptionOrder numberflexible rigid, for tanks rigid, for containers4/6 6/12 4/6 6/12 4/6 6/12without empty signal 531-0100 531-0200 531-0110 531-0210 531-0120 531-0220with empty signal 531-0101 531-0201 531-0111 531-0211 531-0121 531-0221with empty signaland pre-alert531-0102 531-0202 531-0112 531-0212 531-0122 531-0222531-0100531-0200531-0101/-0102531-0201/-0202Different materials, line and cable length on request!Suction lines for ALLDOS tanks• Please indicate the tank size!When ordering together with an ALLDOS dosing tank,the length of the suction line is adapted.• Please indicate, whether you use a tank with or without agitator!For tanks with agitators, the suction line is equipped with a knurled nut.Reed contact float switch• To use as tank empty signal or additional level sensor• To plug on the suction lineDescriptionReed contact PVC with plug and cable 2 m,for connections 4/6 and 6/12Reed contact PP with plug and cable 2 m,for connections 4/6 and 6/12Pressure loading valves 525Order number338-212338-213Necessary, if the dosing system has no backpressure, if the backpressure varies orif the injection point is situated lower than the pump.• Adjustable by a spring-loaded screw, factory pre-adjustment 2 to 3 bars, incl. connections531-0110531-0210531-0120531-0220531-0111/-0112531-0211/-0212531-0121/-0122531-0221/-0222Materialsvalve / gasketConnectionsL[mm]H[mm]h[mm]ø D[mm]OrdernumberPVC / Viton or EPDMHose 4/6 or 6/12,Pipe 10/1296 90 21 68 525-0567.1PP / Viton Hose 4/6 96 90 21 68 525-0565PP / EPDM Hose 4/6 96 90 21 68 525-0565.1PVDF / PTFE Pipe 4/6 120 90 21 68 525-0566.1Stainless steel Pipe 4/6 120 82 11 68 525-0570Stainless steel Pipe R 1/4“ female thread – 82 11 68 525-0571PP / Viton Pipe 12/16 140 90 21 68 525-0568PP / EPDM Pipe 12/16 140 90 21 68 525-0568.1PVDF / PTFE Pipe 14/16 140 90 21 68 525-0569.1Pressure loading valve208/03.05ENPage 6www.alldos.com


Primus 208Diaphragm dosing pumpPressure relief valves 525Protect the line system on the dischange side against too high pressures.• 3-way valve, overflow function by a diaphragm spring system, diaphragm PTFE• Opening pressure adjustable, factory pre-adjustment approx. 11 bar, incl. connectionsMaterialsbody / gasketPVC / Viton orEPDMConnectionsHose 4/6 or 6/12,Pipe 10/12L[mm]B[mm]H[mm]h[mm]ø D[mm]Ordernumber96 48 90 21 68 525-0584.1PP / Viton Hose 4/6 96 48 90 21 68 252-0582PP / EPDM Hose 4/6 96 48 90 21 68 525-0582.1PVDF / PTFE Pipe 4/6 120 60 90 21 68 525-0580.1Stainless steel Pipe 4/6 108 54 82 11 68 525-0581Pressure relief valve PVCPVC / Viton orEPDMHose 4/6 or 6/12,Pipe 10/12opening pressure 17 bar140 49 90 21 68 525-1584.1Stainless steelPipe R 1/4“female thread– – 82 11 69 525-0586PP / Viton Pipe 12/16 140 50 90 21 68 525-0583PP / EPDM Pipe 12/16 140 50 90 21 68 525-0583.1PVDF / PTFE Pipe 14/16 140 50 90 21 68 525-0585.1Injection units 522• Ball check valve, spring Hastelloy C• Threaded piece with integrated injection tube for installation into the threaded sleeveof the process lineMaterialsbody / gasket / ballOrdernumberl[mm]L[mm]T max[C]PN[bar]PVC / Viton / Glass 522-0311 62 11816PVC / EPDM / Stainl. steel 522-0312 62 118 1640°PVC / Viton / Glass522-0411 62 257to 10 bar 16+ ball valvePVC / Viton / Glass+ threaded piece st. steelPVC / Viton / Glass+ lip valve522-0611 62 118522-4931 55 11420°to 16 bar1616ConnectionsHose 6/12 or 4/6,Pipe 10/12PP / Viton / Glass 522-0051 62 121 40° 10 Hose 4/6PVDF / PTFE / Ceramics 522-0081 62 130 50° 16Pipe 4/6St. steel / Viton / St. steel 522-0071 27 118 70° 25St. steel / Viton / St. steelcooling pipe length 1000 mm522-0911522-09627–92–70°–16–1/4“–PP / Viton / Glass 522-0341 62 118 40° 10 Pipe 12/16PVDF / PTFE / PTFE 522-0151 62 118 50° 16 (welding nipple)Pressure relief valve PP/PVDF522-0311/-0312522-0411/-0611522-0051 522-0081 522-0071 522-4931522-0911522-0341/-0151208/03.05ENPage 7www.alldos.com


Primus 208Diaphragm dosing pumpSpare parts sets• Suction and pressure valves (steel: only inner valve parts)• Gaskets for dosing head and valves• 1 deaeration cartridge• 1 dosing diaphragm• 4 screws for the dosing headPumps Materials Order numberDosing head with manual deaeration valvePVC / Viton / Glass 553-1395PVC / EPDM / Ceramics 553-1399208-0.3 PP / Viton / Glass 553-1396208-0.3 IN PP / EPDM / Ceramics 553-1400PVDF / PTFE / Ceramics 553-1401St. steel / PTFE / St. steel 553-1402PVC / Viton / Glass 553-1403208-0.8 toPVC / EPDM / Ceramics 553-1407208-4.0PP / Viton / Glass 553-1404208-0.8 IN toPP / EPDM / Ceramics 553-1408208-4.0 INPVDF / PTFE / Ceramics 553-1409St. steel / PTFE / St. steel 553-1410PVC / Viton / Glass 553-1411208-5.0 andPVC / EPDM / Ceramics 553-1415208-6.0PP / Viton / Glass 553-1412208-5.0 IN andPP / EPDM / Ceramics 553-1416208-6.0 INPVDF / PTFE / Ceramics 553-1417St. steel / PTFE / St. steel 553-1418PVC / Viton / Glass 553-1419208-9.0 toPVC / EPDM / PTFE 553-1423208-18PP / Viton / Glass 553-1420208-9.0 IN toPP / EPDM / PTFE 553-1424208-18 INPVDF / PTFE / PTFE 553-1425St. steel / PTFE / St. steel 553-1426Dosing head with automatic deaeration valvePVC / Viton / Glass 553-1427208-1.6 toPTFE / Viton / PTFE 10.8274-616208-4.0PTFE / EPDM / PTFE 10.8274-615PVC / Viton / Glass 553-1428208-5.0 andPTFE / Viton / PTFE 10.8274-616208-6.0PTFE / EPDM / PTFE 10.8274-615PVC / Viton / Glass 553-1429208-9.0 toPTFE / Viton / PTFE 10.8274-616208-18PTFE / EPDM / PTFE 10.8274-615Transparent cover• For dirt protection: optional for pumps with horizontal display• Material: MakrolonWall console• With fastening materialDescriptionOrder numberPE black 539-006Installation sets• Suction line with check valve and filter• Deaeration and suction hose 1.5 m, pressure hose 5 m• Injection unit G 1/4“ and G 1/2“DescriptionPumps without electronicsSuction line without empty signalPumps with electronicsSuction line with empty signalNot for Primus Inside!Presented by:MaterialOrder numberG 1/4“ G 1/2“PVC 553-048 553-1012 *PP 553-063 553-1014PVC 553-049 553-1013 *PP 553-064 553-1015*) for pumps up to max. 16 bar, the other sets up to max. 10 bar.www.alldos.com© 2005 by ALLDOS Eichler GmbHSubject to change!15.820002 V2.0208/03.05EN