select 3D ®<br />
EOPA 3D ®<br />
ArtEriAl CAnnulAE<br />
<strong>Find</strong> <strong>your</strong> <strong>ideal</strong>.
EOPA 3D ®<br />
ArtEriAl CAnnulAE<br />
the EOPA <strong>3D®</strong> arterial cannulae<br />
from medtronic feature a unique<br />
tapered tip configuration that<br />
diffuses the flow through multiple<br />
outlets. the elongated wirewound<br />
body provides versatility for either<br />
minimally invasive procedures or<br />
traditional median sternotomy<br />
approaches.<br />
EOPA 3D<br />
without obturator<br />
EOPA 3D<br />
with obturator<br />
Pressure Loss (mm Hg)<br />
100<br />
80<br />
60<br />
40<br />
20<br />
Features Benefits<br />
■ Obturator ■ maintains hemostasis<br />
■ Hemostasis<br />
cap<br />
■ 3/8 in. vented ■ luer vent facilitates<br />
or non-vented de-airing after<br />
connector connection<br />
■ 13 in. length ■ Enables access to most<br />
(33.02 cm) areas of the aortic<br />
arch through median<br />
sternotomy or peristernotomy<br />
incisions<br />
■ thin wall ■ maximizes<br />
construction flow rates<br />
■ wirewound ■ Kink resistant,<br />
body maximizes flexibility<br />
■ 20 Fr & 22 Fr ■ selection of sizes<br />
sizes (6.7 mm<br />
& 7.3 mm)<br />
■ Adjustable ■ Allows pre-setting of<br />
radiopaque insertion depth and<br />
suture ring location for ligiture sutures<br />
■ Depth marks ■ indicates insertion<br />
depth at 1 cm intervals<br />
■ 3D diffusion tip ■ Additional outlets<br />
for reduced velocity<br />
diffuse flow<br />
EOPA 3D Arterial Cannulae<br />
Pressure Loss (mm Hg)<br />
during insertion and<br />
cannula priming<br />
20 FR<br />
22 FR<br />
0<br />
0 1 2 3 4<br />
Flow Rate (L/min. of water)<br />
5 6
EOPA 3D ®<br />
ArtEriAl CAnnulAE<br />
lAsEr DOPPlEr AnEmOmEtry<br />
(lDA) PErFOrmAnCE ††<br />
Comparison of flow velocity for 22 Fr EOPA <strong>3D®</strong> arterial<br />
cannulae compared to terumo®-sarns straight tip<br />
extended body soft-Flow® and Edwards rmi straight<br />
tip EZ Glide 24 Fr (8 mm).<br />
EOPA 3D ® – 78222 – 22 Fr<br />
Terumo ® -Sarns Soft-Flow – 4950 – 24 Fr – 8mm<br />
Edwards RMI EZ Glide – EZS24A – 24 Fr – 12mm<br />
†† Data on file at medtronic, inc.<br />
FlOw PErFOrmAnCE<br />
vs. COmPEtitOrs<br />
the EOPA <strong>3D®</strong> arterial cannulae exhibit superior flow<br />
performance. * typically, lower pressure drop is observed<br />
with larger Fr size cannulae due to larger internal<br />
diameter and therefore, less flow restriction. However,<br />
the 3D tip design performs better than traditional open<br />
tip arterial cannulae and competitive diffuse flow arterial<br />
cannulae. this improved flow 100 performance is 18 FR achieved<br />
20 FR<br />
by the design of the 3D tip 80 providing open central 22 as FR<br />
well as diverted flow streams. 60<br />
Pressure Loss (mm Hg)<br />
these flow charts show the improved flow performance<br />
20<br />
of the EOPA 3D compared to competitors’ elongated or<br />
0<br />
0 1 2 3 4 5 6<br />
extended body straight tip diffuse Flow flow Rate (L/min. arterial of water) models:<br />
Both 20 Fr and 22<br />
Fr EOPA 3D cannulae<br />
have lower pressure<br />
drops than 21 Fr and 24<br />
Fr competitors models.*<br />
Both 20 Fr and 22 Fr<br />
EOPA 3D cannulae<br />
have lower pressure<br />
drops than 24 Fr Estech <br />
EasyFlow cannulae.*<br />
Important Safety Information<br />
Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery<br />
procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use.<br />
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.<br />
Pressure Pressure Loss Loss (mm (mm Hg) Hg)<br />
180<br />
160<br />
140<br />
120<br />
Estech<br />
#103-300<br />
24 FR<br />
100<br />
MDT<br />
#78320<br />
80<br />
20 FR<br />
60<br />
MDT<br />
#78322<br />
40<br />
20<br />
0<br />
22 FR<br />
0 1 2 3 4<br />
Flow Rate (L/min. of water)<br />
5 6<br />
Pressure Loss (mm Hg)<br />
40<br />
EOPA 3D arterial cannulae vs.<br />
Estech EasyFlow<br />
24 FR<br />
EOPA 3D arterial cannulae vs.<br />
Terumo Sarns Soft-Flow Extended<br />
100<br />
180<br />
18 FR<br />
20 FR<br />
160 80<br />
140<br />
120 60<br />
22 FR<br />
Sarns<br />
#4949<br />
7.0mm (21 FR)<br />
24 FR<br />
100<br />
80 40<br />
60<br />
20<br />
40<br />
MDT<br />
#78320<br />
20 FR<br />
Sarns<br />
#4950<br />
8.0mm (24 FR)<br />
MDT<br />
#78322<br />
22 FR<br />
20<br />
0<br />
0 0<br />
0<br />
1<br />
1<br />
2 3 4<br />
Flow 2 Rate (L/min. 3 of water) 4<br />
Flow Rate (L/min. of water)<br />
5<br />
5<br />
6<br />
6<br />
180<br />
160<br />
Edwards<br />
140<br />
120<br />
#EZS21TA<br />
21 FR<br />
100<br />
MDT<br />
#78320<br />
20 FR<br />
80<br />
60<br />
40<br />
20<br />
0<br />
Edwards<br />
#EZS24TA<br />
24 FR<br />
MDT<br />
#78322<br />
22 FR<br />
0 1 2 3 4<br />
Flow Rate (L/min. of water)<br />
5 6<br />
Pressure Loss (mm Hg)<br />
EOPA 3D arterial cannulae vs.<br />
Edwards RMI EZ Glide Straight Tip<br />
*Data on file at medtronic, inc.
select 3D ® and select 3D ® ii<br />
ArtEriAl CAnnulAE<br />
the slight angle of the 3D tip diverted<br />
flows, along with the open tip flow,<br />
create a more centralized<br />
pattern within the aorta.<br />
the select <strong>3D®</strong> and select <strong>3D®</strong> ii arterial<br />
cannulae from medtronic feature a tip<br />
configuration that diffuses the flow<br />
through multiple outlets. this unique<br />
tip design provides reduced velocity<br />
with one central and three diverted<br />
flow streams.<br />
select<br />
3D<br />
Cannula<br />
select<br />
3D ii<br />
Cannula<br />
Features<br />
■ Peel away cap<br />
■ 3/8 in. vented<br />
or non-vented<br />
connector<br />
■ thin wall<br />
construction<br />
■ wirewound<br />
body<br />
■ stop collar<br />
■ 3D diffusion tip<br />
Important Safety Information<br />
Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery<br />
procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use.<br />
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.<br />
Benefits<br />
■ Allows complete<br />
priming of<br />
cannula and<br />
connector<br />
■ luer vent<br />
facilitates<br />
de-airing after<br />
connection<br />
■ maximizes<br />
flow rates<br />
■ Kink resistant,<br />
maximizes flexibility<br />
■ location for securing<br />
ligature sutures<br />
■ Additional outlets<br />
for reduced velocity<br />
diffuse flow
select 3D ® and select 3D ® ii<br />
ArtEriAl CAnnulAE<br />
lAsEr DOPPlEr AnEmOmEtry<br />
(lDA) PErFOrmAnCE †<br />
laser doppler anemometry testing demonstrates that<br />
the select <strong>3D®</strong> arterial cannula features significantly<br />
reduced velocity compared to a standard open<br />
tip arterial cannula while also maintaining a more<br />
centralized flow pattern compared to competitive<br />
diffuse flow arterial cannulae.<br />
Comparison of flow velocity for 24 Fr arterial cannulae<br />
at 6 lPm. velocity measurements at 12mm from<br />
cannula tip for the select 3D (diffuse flow), a standard<br />
open tip angled (non-diffuse flow), terumo®-sarns<br />
angled soft-Flow® (diffuse flow).<br />
<strong>Medtronic</strong>-DLP 78624 – 24 Fr<br />
<strong>Medtronic</strong>-DLP 72524 – 24 Fr<br />
Terumo ® -Sarns Soft-Flow - 5768 – 24 Fr - 8 mm<br />
† Data on file at medtronic, inc.<br />
FlOw PErFOrmAnCE<br />
COmPArisOn<br />
Select 3D and Select 3D II Arterial Cannulae<br />
Pressure Loss (mm Hg)<br />
100<br />
80<br />
60<br />
40<br />
20<br />
18 FR<br />
20 FR<br />
22 FR<br />
24 FR<br />
0<br />
0 1 2 3 4<br />
Flow Rate (L/min. of water)<br />
5 6<br />
the unique design of the 3D arterial cannulae<br />
tip results in lower arterial line pressures than<br />
a conventional open tip arterial cannula or<br />
competitive diffuse flow arterial cannula.<br />
Line Pressure (mm of Hg)<br />
Average Line Pressure – 24 Fr Arterial Cannulae<br />
Average Line Pressure – 24 Fr Arterial Cannula<br />
(Closed Circuit Using Blood)<br />
250<br />
200<br />
150<br />
100<br />
50<br />
0<br />
112.20<br />
Select 3D<br />
24 Fr Angled<br />
(<strong>Medtronic</strong>-<br />
DLP 78624)<br />
(Closed Circuit Using Blood)<br />
127.73<br />
Open Tip<br />
24 Fr Curved<br />
(<strong>Medtronic</strong>-<br />
DLP 83024)<br />
156.47<br />
Soft-�ow®<br />
24 Fr Angled<br />
Terumo®-Sarns<br />
5768<br />
laboratory comparison of arterial line pressures at 6 liters<br />
per minute*<br />
*Data on file at medtronic, inc.
Ordering information<br />
Select <strong>3D®</strong> Cannulae<br />
Dip-molded tip and Body<br />
Vented<br />
Product Number Description Quantity<br />
78618 18 Fr w/3/8 in. connector 20/carton<br />
78620 20 Fr w/3/8 in. connector 20/carton<br />
78622 22 Fr w/3/8 in. connector 20/carton<br />
78624 24 Fr w/3/8 in. connector 20/carton<br />
Select <strong>3D®</strong>II Cannulae<br />
injection-molded tip and Dip-molded Body<br />
Vented<br />
Product Number Description Quantity<br />
78420 20 Fr w/3/8 in. connector 20/carton<br />
78422 22 Fr w/3/8 in. connector 20/carton<br />
78424 24 Fr w/3/8 in. connector 20/carton<br />
EOPA <strong>3D®</strong> Cannulae<br />
Diffusion tip and Elongated Body<br />
Vented<br />
Product Number Description Quantity<br />
78220 20 Fr w/3/8 in. connector 10/carton<br />
78222 22 Fr w/3/8 in. connector 10/carton<br />
Also available with Carmeda® BioActive Surface. Manufactured under license from Carmeda AB, Sweden. Carmeda is a registered trademark of Carmeda AB.<br />
Carmeda Bonded models may be ordered using “CB” as a prefix to the product number.<br />
trademarks may be registered and are the property of their respective owners.<br />
EasyFlow is a trademark of Estech. Edwards and EZ Glide are trademarks of Edwards lifesciences Corporation.<br />
terumo is a registered trademark of terumo Corporation. sarns is a trademark of terumo Cardiovascular systems Corporation.<br />
soft-Flow is a registered trademark of terumo Cardiovascular systems Corporation.<br />
For more information, contact <strong>your</strong> local medtronic Cannula Products representative. u.s. Customer service: 1-800-328-1357.<br />
www.medtronic.com<br />
World Headquarters<br />
<strong>Medtronic</strong>, Inc.<br />
710 <strong>Medtronic</strong> Parkway<br />
Minneapolis, MN 55432-5604<br />
USA<br />
Tel: (763) 514-4000<br />
Fax: (763) 514-4879<br />
<strong>Medtronic</strong> USA, Inc.<br />
Toll-free: 1 (800) 328-2518<br />
Europe<br />
<strong>Medtronic</strong> International Trading Sàrl<br />
Route du Molliau 31<br />
Case postale 84<br />
CH-1131 Tolochenaz<br />
Switzerland<br />
Tel: 41.21.802.7000<br />
Fax: 41.21.802.7900<br />
Canada<br />
<strong>Medtronic</strong> of Canada Ltd.<br />
99 Hereford Street<br />
Brampton, Ontario L6Y 0R3<br />
Canada<br />
Tel: (905) 460-3800<br />
Fax: (905) 826-6620<br />
Toll-free: 1 (800) 268-5346<br />
Non-Vented<br />
Product Number Description Quantity<br />
78718 18 Fr w/3/8 in. connector 20/carton<br />
78720 20 Fr w/3/8 in. connector 20/carton<br />
78722 22 Fr w/3/8 in. connector 20/carton<br />
78724 24 Fr w/3/8 in. connector 20/carton<br />
Non-Vented<br />
Product Number Description Quantity<br />
78520 20 Fr w/3/8 in. connector 20/carton<br />
78522 22 Fr w/3/8 in. connector 20/carton<br />
78524 24 Fr w/3/8 in. connector 20/carton<br />
Non-Vented<br />
Product Number Description Quantity<br />
78320 20 Fr w/3/8 in. connector 10/carton<br />
78322 22 Fr w/3/8 in. connector 10/carton<br />
Important Safety Information<br />
Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery<br />
procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use.<br />
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.<br />
Asia<br />
<strong>Medtronic</strong> International Ltd.<br />
49 Changi South Avenue 2<br />
Nasaco Tech Centre<br />
Singapore 486056<br />
Singapore<br />
Tel: (65) 6436 5000<br />
Fax: (65) 6776 6335<br />
Latin America<br />
<strong>Medtronic</strong> USA, Inc.<br />
Doral Corporate Center II<br />
3750 NW 87th Avenue Suite 700<br />
Miami, FL 33178<br />
USA<br />
Tel: (305) 500-9328<br />
Fax: (786) 709-4244<br />
LifeLine<br />
CardioVascular Technical Support<br />
Tel: (877) 526-7890<br />
Tel: (763) 526-7890<br />
Fax: (763) 526-7888<br />
E-mail: rs.cstechsupport@medtronic.com<br />
uC20110XXXX uC200701639b En En © © medtronic, 2012 medtronic, inc. 2011. inc. All rights reserved. Printed in usA