30.11.2012 Views

Eopa 3D® artErial CannulaE - Find your ideal - Medtronic

Eopa 3D® artErial CannulaE - Find your ideal - Medtronic

Eopa 3D® artErial CannulaE - Find your ideal - Medtronic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

select 3D ®<br />

EOPA 3D ®<br />

ArtEriAl CAnnulAE<br />

<strong>Find</strong> <strong>your</strong> <strong>ideal</strong>.


EOPA 3D ®<br />

ArtEriAl CAnnulAE<br />

the EOPA <strong>3D®</strong> arterial cannulae<br />

from medtronic feature a unique<br />

tapered tip configuration that<br />

diffuses the flow through multiple<br />

outlets. the elongated wirewound<br />

body provides versatility for either<br />

minimally invasive procedures or<br />

traditional median sternotomy<br />

approaches.<br />

EOPA 3D<br />

without obturator<br />

EOPA 3D<br />

with obturator<br />

Pressure Loss (mm Hg)<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Features Benefits<br />

■ Obturator ■ maintains hemostasis<br />

■ Hemostasis<br />

cap<br />

■ 3/8 in. vented ■ luer vent facilitates<br />

or non-vented de-airing after<br />

connector connection<br />

■ 13 in. length ■ Enables access to most<br />

(33.02 cm) areas of the aortic<br />

arch through median<br />

sternotomy or peristernotomy<br />

incisions<br />

■ thin wall ■ maximizes<br />

construction flow rates<br />

■ wirewound ■ Kink resistant,<br />

body maximizes flexibility<br />

■ 20 Fr & 22 Fr ■ selection of sizes<br />

sizes (6.7 mm<br />

& 7.3 mm)<br />

■ Adjustable ■ Allows pre-setting of<br />

radiopaque insertion depth and<br />

suture ring location for ligiture sutures<br />

■ Depth marks ■ indicates insertion<br />

depth at 1 cm intervals<br />

■ 3D diffusion tip ■ Additional outlets<br />

for reduced velocity<br />

diffuse flow<br />

EOPA 3D Arterial Cannulae<br />

Pressure Loss (mm Hg)<br />

during insertion and<br />

cannula priming<br />

20 FR<br />

22 FR<br />

0<br />

0 1 2 3 4<br />

Flow Rate (L/min. of water)<br />

5 6


EOPA 3D ®<br />

ArtEriAl CAnnulAE<br />

lAsEr DOPPlEr AnEmOmEtry<br />

(lDA) PErFOrmAnCE ††<br />

Comparison of flow velocity for 22 Fr EOPA <strong>3D®</strong> arterial<br />

cannulae compared to terumo®-sarns straight tip<br />

extended body soft-Flow® and Edwards rmi straight<br />

tip EZ Glide 24 Fr (8 mm).<br />

EOPA 3D ® – 78222 – 22 Fr<br />

Terumo ® -Sarns Soft-Flow – 4950 – 24 Fr – 8mm<br />

Edwards RMI EZ Glide – EZS24A – 24 Fr – 12mm<br />

†† Data on file at medtronic, inc.<br />

FlOw PErFOrmAnCE<br />

vs. COmPEtitOrs<br />

the EOPA <strong>3D®</strong> arterial cannulae exhibit superior flow<br />

performance. * typically, lower pressure drop is observed<br />

with larger Fr size cannulae due to larger internal<br />

diameter and therefore, less flow restriction. However,<br />

the 3D tip design performs better than traditional open<br />

tip arterial cannulae and competitive diffuse flow arterial<br />

cannulae. this improved flow 100 performance is 18 FR achieved<br />

20 FR<br />

by the design of the 3D tip 80 providing open central 22 as FR<br />

well as diverted flow streams. 60<br />

Pressure Loss (mm Hg)<br />

these flow charts show the improved flow performance<br />

20<br />

of the EOPA 3D compared to competitors’ elongated or<br />

0<br />

0 1 2 3 4 5 6<br />

extended body straight tip diffuse Flow flow Rate (L/min. arterial of water) models:<br />

Both 20 Fr and 22<br />

Fr EOPA 3D cannulae<br />

have lower pressure<br />

drops than 21 Fr and 24<br />

Fr competitors models.*<br />

Both 20 Fr and 22 Fr<br />

EOPA 3D cannulae<br />

have lower pressure<br />

drops than 24 Fr Estech <br />

EasyFlow cannulae.*<br />

Important Safety Information<br />

Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery<br />

procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use.<br />

Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.<br />

Pressure Pressure Loss Loss (mm (mm Hg) Hg)<br />

180<br />

160<br />

140<br />

120<br />

Estech<br />

#103-300<br />

24 FR<br />

100<br />

MDT<br />

#78320<br />

80<br />

20 FR<br />

60<br />

MDT<br />

#78322<br />

40<br />

20<br />

0<br />

22 FR<br />

0 1 2 3 4<br />

Flow Rate (L/min. of water)<br />

5 6<br />

Pressure Loss (mm Hg)<br />

40<br />

EOPA 3D arterial cannulae vs.<br />

Estech EasyFlow<br />

24 FR<br />

EOPA 3D arterial cannulae vs.<br />

Terumo Sarns Soft-Flow Extended<br />

100<br />

180<br />

18 FR<br />

20 FR<br />

160 80<br />

140<br />

120 60<br />

22 FR<br />

Sarns<br />

#4949<br />

7.0mm (21 FR)<br />

24 FR<br />

100<br />

80 40<br />

60<br />

20<br />

40<br />

MDT<br />

#78320<br />

20 FR<br />

Sarns<br />

#4950<br />

8.0mm (24 FR)<br />

MDT<br />

#78322<br />

22 FR<br />

20<br />

0<br />

0 0<br />

0<br />

1<br />

1<br />

2 3 4<br />

Flow 2 Rate (L/min. 3 of water) 4<br />

Flow Rate (L/min. of water)<br />

5<br />

5<br />

6<br />

6<br />

180<br />

160<br />

Edwards<br />

140<br />

120<br />

#EZS21TA<br />

21 FR<br />

100<br />

MDT<br />

#78320<br />

20 FR<br />

80<br />

60<br />

40<br />

20<br />

0<br />

Edwards<br />

#EZS24TA<br />

24 FR<br />

MDT<br />

#78322<br />

22 FR<br />

0 1 2 3 4<br />

Flow Rate (L/min. of water)<br />

5 6<br />

Pressure Loss (mm Hg)<br />

EOPA 3D arterial cannulae vs.<br />

Edwards RMI EZ Glide Straight Tip<br />

*Data on file at medtronic, inc.


select 3D ® and select 3D ® ii<br />

ArtEriAl CAnnulAE<br />

the slight angle of the 3D tip diverted<br />

flows, along with the open tip flow,<br />

create a more centralized<br />

pattern within the aorta.<br />

the select <strong>3D®</strong> and select <strong>3D®</strong> ii arterial<br />

cannulae from medtronic feature a tip<br />

configuration that diffuses the flow<br />

through multiple outlets. this unique<br />

tip design provides reduced velocity<br />

with one central and three diverted<br />

flow streams.<br />

select<br />

3D<br />

Cannula<br />

select<br />

3D ii<br />

Cannula<br />

Features<br />

■ Peel away cap<br />

■ 3/8 in. vented<br />

or non-vented<br />

connector<br />

■ thin wall<br />

construction<br />

■ wirewound<br />

body<br />

■ stop collar<br />

■ 3D diffusion tip<br />

Important Safety Information<br />

Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery<br />

procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use.<br />

Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.<br />

Benefits<br />

■ Allows complete<br />

priming of<br />

cannula and<br />

connector<br />

■ luer vent<br />

facilitates<br />

de-airing after<br />

connection<br />

■ maximizes<br />

flow rates<br />

■ Kink resistant,<br />

maximizes flexibility<br />

■ location for securing<br />

ligature sutures<br />

■ Additional outlets<br />

for reduced velocity<br />

diffuse flow


select 3D ® and select 3D ® ii<br />

ArtEriAl CAnnulAE<br />

lAsEr DOPPlEr AnEmOmEtry<br />

(lDA) PErFOrmAnCE †<br />

laser doppler anemometry testing demonstrates that<br />

the select <strong>3D®</strong> arterial cannula features significantly<br />

reduced velocity compared to a standard open<br />

tip arterial cannula while also maintaining a more<br />

centralized flow pattern compared to competitive<br />

diffuse flow arterial cannulae.<br />

Comparison of flow velocity for 24 Fr arterial cannulae<br />

at 6 lPm. velocity measurements at 12mm from<br />

cannula tip for the select 3D (diffuse flow), a standard<br />

open tip angled (non-diffuse flow), terumo®-sarns<br />

angled soft-Flow® (diffuse flow).<br />

<strong>Medtronic</strong>-DLP 78624 – 24 Fr<br />

<strong>Medtronic</strong>-DLP 72524 – 24 Fr<br />

Terumo ® -Sarns Soft-Flow - 5768 – 24 Fr - 8 mm<br />

† Data on file at medtronic, inc.<br />

FlOw PErFOrmAnCE<br />

COmPArisOn<br />

Select 3D and Select 3D II Arterial Cannulae<br />

Pressure Loss (mm Hg)<br />

100<br />

80<br />

60<br />

40<br />

20<br />

18 FR<br />

20 FR<br />

22 FR<br />

24 FR<br />

0<br />

0 1 2 3 4<br />

Flow Rate (L/min. of water)<br />

5 6<br />

the unique design of the 3D arterial cannulae<br />

tip results in lower arterial line pressures than<br />

a conventional open tip arterial cannula or<br />

competitive diffuse flow arterial cannula.<br />

Line Pressure (mm of Hg)<br />

Average Line Pressure – 24 Fr Arterial Cannulae<br />

Average Line Pressure – 24 Fr Arterial Cannula<br />

(Closed Circuit Using Blood)<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

112.20<br />

Select 3D<br />

24 Fr Angled<br />

(<strong>Medtronic</strong>-<br />

DLP 78624)<br />

(Closed Circuit Using Blood)<br />

127.73<br />

Open Tip<br />

24 Fr Curved<br />

(<strong>Medtronic</strong>-<br />

DLP 83024)<br />

156.47<br />

Soft-�ow®<br />

24 Fr Angled<br />

Terumo®-Sarns<br />

5768<br />

laboratory comparison of arterial line pressures at 6 liters<br />

per minute*<br />

*Data on file at medtronic, inc.


Ordering information<br />

Select <strong>3D®</strong> Cannulae<br />

Dip-molded tip and Body<br />

Vented<br />

Product Number Description Quantity<br />

78618 18 Fr w/3/8 in. connector 20/carton<br />

78620 20 Fr w/3/8 in. connector 20/carton<br />

78622 22 Fr w/3/8 in. connector 20/carton<br />

78624 24 Fr w/3/8 in. connector 20/carton<br />

Select <strong>3D®</strong>II Cannulae<br />

injection-molded tip and Dip-molded Body<br />

Vented<br />

Product Number Description Quantity<br />

78420 20 Fr w/3/8 in. connector 20/carton<br />

78422 22 Fr w/3/8 in. connector 20/carton<br />

78424 24 Fr w/3/8 in. connector 20/carton<br />

EOPA <strong>3D®</strong> Cannulae<br />

Diffusion tip and Elongated Body<br />

Vented<br />

Product Number Description Quantity<br />

78220 20 Fr w/3/8 in. connector 10/carton<br />

78222 22 Fr w/3/8 in. connector 10/carton<br />

Also available with Carmeda® BioActive Surface. Manufactured under license from Carmeda AB, Sweden. Carmeda is a registered trademark of Carmeda AB.<br />

Carmeda Bonded models may be ordered using “CB” as a prefix to the product number.<br />

trademarks may be registered and are the property of their respective owners.<br />

EasyFlow is a trademark of Estech. Edwards and EZ Glide are trademarks of Edwards lifesciences Corporation.<br />

terumo is a registered trademark of terumo Corporation. sarns is a trademark of terumo Cardiovascular systems Corporation.<br />

soft-Flow is a registered trademark of terumo Cardiovascular systems Corporation.<br />

For more information, contact <strong>your</strong> local medtronic Cannula Products representative. u.s. Customer service: 1-800-328-1357.<br />

www.medtronic.com<br />

World Headquarters<br />

<strong>Medtronic</strong>, Inc.<br />

710 <strong>Medtronic</strong> Parkway<br />

Minneapolis, MN 55432-5604<br />

USA<br />

Tel: (763) 514-4000<br />

Fax: (763) 514-4879<br />

<strong>Medtronic</strong> USA, Inc.<br />

Toll-free: 1 (800) 328-2518<br />

Europe<br />

<strong>Medtronic</strong> International Trading Sàrl<br />

Route du Molliau 31<br />

Case postale 84<br />

CH-1131 Tolochenaz<br />

Switzerland<br />

Tel: 41.21.802.7000<br />

Fax: 41.21.802.7900<br />

Canada<br />

<strong>Medtronic</strong> of Canada Ltd.<br />

99 Hereford Street<br />

Brampton, Ontario L6Y 0R3<br />

Canada<br />

Tel: (905) 460-3800<br />

Fax: (905) 826-6620<br />

Toll-free: 1 (800) 268-5346<br />

Non-Vented<br />

Product Number Description Quantity<br />

78718 18 Fr w/3/8 in. connector 20/carton<br />

78720 20 Fr w/3/8 in. connector 20/carton<br />

78722 22 Fr w/3/8 in. connector 20/carton<br />

78724 24 Fr w/3/8 in. connector 20/carton<br />

Non-Vented<br />

Product Number Description Quantity<br />

78520 20 Fr w/3/8 in. connector 20/carton<br />

78522 22 Fr w/3/8 in. connector 20/carton<br />

78524 24 Fr w/3/8 in. connector 20/carton<br />

Non-Vented<br />

Product Number Description Quantity<br />

78320 20 Fr w/3/8 in. connector 10/carton<br />

78322 22 Fr w/3/8 in. connector 10/carton<br />

Important Safety Information<br />

Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery<br />

procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use.<br />

Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.<br />

Asia<br />

<strong>Medtronic</strong> International Ltd.<br />

49 Changi South Avenue 2<br />

Nasaco Tech Centre<br />

Singapore 486056<br />

Singapore<br />

Tel: (65) 6436 5000<br />

Fax: (65) 6776 6335<br />

Latin America<br />

<strong>Medtronic</strong> USA, Inc.<br />

Doral Corporate Center II<br />

3750 NW 87th Avenue Suite 700<br />

Miami, FL 33178<br />

USA<br />

Tel: (305) 500-9328<br />

Fax: (786) 709-4244<br />

LifeLine<br />

CardioVascular Technical Support<br />

Tel: (877) 526-7890<br />

Tel: (763) 526-7890<br />

Fax: (763) 526-7888<br />

E-mail: rs.cstechsupport@medtronic.com<br />

uC20110XXXX uC200701639b En En © © medtronic, 2012 medtronic, inc. 2011. inc. All rights reserved. Printed in usA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!